Viking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current Masterspec Specifications for Viking Butylclad / Epiclad Batten Screw Fixed to substrate and spaced to suit Waterproof Membrane sheet width Viking 76mm Lap Tape DRAWING STATUS ISSUE Detail Ref: DATE DRAWN Not to Scale 22/5/2012 DRAWING TITLE Butylclad / Epiclad Batten Lap Joint NOTES: Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz A INFORMATION ONLY AF BE01

Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Embed Size (px)

Citation preview

Page 1: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Viking Butylclad / EpicladWaterproofing Membrane

Substrate to comply with current MasterspecSpecifications for Viking Butylclad / Epiclad

Batten Screw Fixed to substrate and spaced to suit Waterproof Membrane sheet width

Viking 76mm Lap Tape

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladBatten Lap Joint

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE01

Page 2: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Viking Butylclad / EpicladWaterproofing Membrane

Substrate to comply with current MasterspecSpecifications for Viking Butylclad / Epiclad

'Z' = Variable according to wind zoning.

Please refer to table 7 page 39 E2/AS1

*The membrane must extend across the top ofthe parapet and down the outside of the parapet.*The top of the parapet substrate must beangled to allow water to run off the top of the parapet.*All fixings for the cap flashing must be through theside of the flashing.

Cap Flashing & Waterproof Fixings

Minimum 20mm Angle Fillet

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladParapet Wall Transition

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE02

Page 3: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

A

B

C

D

E

F

G

H

I

J

K

L

Rainhead

Overall Width

Overall Length

Depth

Overflow Ø

Main Outlet Ø

Outlet Pipe Length

Outlet Pipe Length

Outlet Position

Flange Width

Flange Thickness

Overflow Spigot Ø

Overflow Spigot

IMR100 IMR120 IMR130

300 300 380

450 450 580

164 200 275

75 / 100 100 / 150 150 / 200

75 /100 100 / 150 150 / 200

140 140 140

60 60 60

150 170 250

30 30 30

4 4 4

98 145 195

208 240 270

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladSumps

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE03

Page 4: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Viking Butylclad / EpicladWaterproofing Membrane

Substrate to comply with current MasterspecSpecifications for Viking Butylclad / Epiclad

Minimum 20mm Angle Fillet

Over Flashing from Skylight, Vent, etc.

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladSkylight Upstand

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE04

Page 5: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Viking Butylclad / EpicladWaterproofing Membrane

Viking Butylclad / EpicladWaterproofing Membrane

Substrate with recess for Scupper to comply with current Masterspec Specifications for Butylclad / Epiclad

Substrate with recess for Scupper tocomply with current MasterspecSpecifications for Viking Butylclad / Epiclad

Proprietary Viking Scupperplaced into recess

Down Pipe to suit Scupper

Viking 76mm Lap Tape

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladScupper Outlet

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE05

Page 6: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Substrate

Penetration

Viking Butylclad / EpicladWaterproofing Membrane

Viking Flashing TapeSET153

Viking Sealant SES012

Viking 76mm Laptape SMT076VOne layer underneath membraneand second layer over the membrane

*Note Viking Lap Seam Primer to be used with Lap Tape

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladPipe Penetration

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE06

Page 7: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Viking Butylclad / EpicladWaterproofing Membrane

Substrate to comply with current MasterspecSpecifications for Viking Butylclad / Epiclad

Aluminium Flashing

Fascia

Viking 76mm Lap Tape

Gutter

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladEaves Gutter

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE07

Page 8: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Viking Butylclad / EpicladWaterproofing Membrane with Lap onvertical top edge. Option 1

Substrate to comply with current MasterspecSpecifications for Viking Butylclad / Epiclad

Viking Butylclad / EpicladWaterproofing Membrane with Lap ontop edge. Option 2

Viking 76mm Lap Tape

* Please note lap option 1 or 2 for Internal Gutter(approved for Viking Butylclad / Epiclad)

Beveled Edge

Minimum 20mm Angle Fillet

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladInternal Gutter

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE08

Page 9: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Viking Butylclad / EpicladWaterproofing Membrane

Substrate to comply with currentMasterspec Specifications for Butylclad / Epiclad

'Z' = Variable according to wind zoning.Please refer to table 7 page 39 E2/AS1

Cut Chase and seal with STP860 Viking Sealant

Built Structure

Packer

Flashing

Rubber SealantViking SES012

Fastening Bar SDF110

Fixing

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale14/5/2012

DRAWING TITLE

Butylclad / EpicladChase Flashing on Upstand

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE09

Page 10: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

'Z' = variable according to wind zoning.

please refer to table 7 page 39 E2/AS1

* Gutters must be sized to E2/AS1 paragraph 8.5.10

please refer to page 90 fig 64b & 64c E2/AS1

* All internal corners must have minimum 20mm angle fillet, all external corners must be have a minimum 5mm radius.

* The membrane must extend across the top of the parapet and down the outside of the parapet.

* The top of the parapet substrate, must be angled to allow water to run off the top of the parapet.

* All fixings for the cap flashing, must be through the side of the flashing.

Roof Cladding

Cap Flashing & Fixings

Minimum 20mmAngle Fillet

Viking Butylclad / EpicladWaterproofing Membrane

Steel Purlin

Substrate to comply with currentMasterspec specifications for Butylclad / Enviroclad

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/7/2012

DRAWING TITLE

Butylclad / EpicladInternal Gutter for Metal Roof

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE10

Page 11: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Removable Leaf Grate

Screw Viking Butylclad / EpicladWaterproofing Membrane

Substrate to comply with current MasterspecSpecifications for Viking Butylclad / Epiclad

Recess for Dropper / Roof Drain

* All Outlets must be recessed into the substrate to allowwater to flow freely into the outlet. This will avoid water pondingaround the outlet.

Sealant SES012

Viking Dropper / Roof Drain

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladDropper / Roof Drain Outlet

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE11

Page 12: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Selected Cladding

Viking Butylclad / EpicladWaterproofing Membrane

Cavity Batten

Substrate to comply with currentMasterspec Specifications for Viking Butylclad / Epiclad

Cavity Base Closer

'X' = Minimum of 35mm at highest point of deck

'Y' = Minimum of 10mm Drip edge

Wall Underlay

Minimum 20mm Angle Fillet

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladCavity Wall Upstand

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE12

Page 13: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Viking Butylclad / EpicladWaterproofing Membrane

Substrate to comply with currentMasterspec Specifications for Viking Butylclad / Epiclad

'Z' = Variable according to wind zoning.Please refer to table 7 page 39 E2/AS1

Sealant - STP870 Viking Fastening Bar - SDF110

Flashing and Fixing

* This detail is recommended if chase cut is not possible.( Precast concrete panels)

Sealant - STP860

Minimum 20mm Angle Fillet

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladExposed Wall Transition

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE13

Page 14: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Substrate to comply with current MasterspecSpecifications for Viking Butylclad / Epiclad

Viking Flashing TapeSET153

Fixing Bracket

Viking Butylclad / EpicladWaterproofing Membrane

Bolt or Screw with washerand Water cut off Mastic under

Plinth

DRAWING STATUS

ISSUEDetail Ref:DATE

DRAWN

Not to Scale22/5/2012

DRAWING TITLE

Butylclad / EpicladRoof Fixing

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY

AF BE15

Page 15: Viking 76mm Lap Tape Batten Screw Fixed to …bkaviking.blob.core.windows.net/media/11101/Full-Set.pdfViking Butylclad / Epiclad Waterproofing Membrane Substrate to comply with current

Rubber Pipe SealSEM020

Pressure sensitive Lap tapeViking Butylclad/EpicladWaterproofing Membrane

Substrate to comply with currentMasterspec Specifications for Butylclad/Epiclad

Vent Top (Grey)

Water cut off Mastic STP870

Clamp Ring

Cavity VentIMV111

Ceiling Cavity

DRAWING STATUS

ISSUESHEET NO.DATE

DRAWN

NOT TO SCALE

BE1920/8/2012

DRAWING TITLE

Butylclad/EpicladAluminium Vent / Pipe Penetration

NOTES:

Viking Roofspec Ltd, Otara, P.O.Box 90 080, Auckland, New Zealand, Telephone 0800 729799, Facsimile 0800 729788, Web Site www.Vikingroofspec.co.nz

A

INFORMATION ONLY