Venue Info & Technical Specifications 1. Address & Map Link to Load In 2. Contact Information 3. General Information, Stage & Power 4. Audio & Lighting Summaries 5. Monitor System & Stage Equipment 6. FOH & Outboard Equipment 7. Lighting Plot 8. House Rig Quick Patch 9. Stage Layout with Power Services 10. Stage Layout with House Pipes / Fly Bars 11. Theatre Floor Plan, Main Level 12. Directions to Venue 13. Map of Area with Parking Positions 14. Map of Offsite Parking 15. Parking Restrictions / Street Sweeping Venue & Delivery Address: The Warfield Theatre 982 Market Street SF, CA 94102 All deliveries should be scheduled for day-of-show whenever possible. Load In / Stage Door: 26 Taylor Street San Francisco, CA Map: http://bit.ly/warfield
Contact Information: General Manager: Doug Elkins 903-436-1280 Phone [email protected] Production Manager: Justin Katz 510-506-2210 Phone [email protected] House Manager, Settlement, Merchandise: Larry Sykes 415-345-1265 Phone 415-345-8746 Fax [email protected] Private Events, Sales & Marketing: Bailey Nakano 415-447-4909 Phone 760-201-7817 [email protected] Promoter: Goldenvoice 1290 Sutter Street, Suite 206 San Francisco, CA 94109 415-777-1715 Phone 415-255-0220 Fax www.goldenvoice.com Goldenvoice Booking: David Lefkowitz 415-777-1715 Phone 415-255-0220 Fax [email protected] Goldenvoice Marketing: Justine Fields 415-442-1867 Phone [email protected] Goldenvoice Ticketing / Box Office: Shane Mealor 415-777-1715 Office 415-794-5562 Cell [email protected] Audio Advance: Nate Harlow 415-431-3523 Phone [email protected] Lighting Advance: Rob Robertson 415-216-3597 Phone [email protected]
General Information: Capacity: 2350 with Dance Floor, 1800 Seated or per deal Dressing Rooms: 6 Backstage Bathrooms: 2 Showers: 2 (1 per bathroom) Stage Barricade: Yes (“Mojo” type, blow-through) Wi-Fi: Yes Network: “Internet Archive ap123”, no password Touring Production: 415-345-0905 DAYTIME SOUND CURFEW 3:00 PM, MON – FRI, NO EXCEPTIONS. Stage Dimensions: Proscenium: 45' Wide x 22' High (to bottom of curtain) / 40' High (total height) Stage Dimensions: 45' Wide x 36' Deep x 58' High Sound Wings: 9' Wide x 4' Deep Fire Curtain: Yes Apron to Curtain: 6' Curtain to USC: 30' Total Stage Width: Down Stage = 54' Up Stage = 46' Stage to Ceiling: 58' Dance Floor to Ceiling: 63' Fly System: Counter Balance with 23 Double Hung Pipes Wt. Capacity of Fly Bars: 700 lbs each w/total weight of 2500 lbs / arbor lengths vary Power (see page 9 for location): Lights (Stage Right): 400 Amps (3 Phase) 25' from Up Stage Center Sound (Stage Left): 200 Amps (3 Phase) 25' from Up Stage Center Shore Power: NO
Audio Summary: Stacks & Racks: 11 x Meyer MILO Line Array loudspeakers flown per side 4 x Meyer 700HP line array sub-bass loudspeakers per side under wings 3 x Meyer 700HP line array sub-bass loudspeakers – flown center array 6 x Meyer MD1 under-balcony delay loudspeakers 3 x Meyer CQ1 powered loudspeakers per side used as front fills System Drive & EQ: Meyer Galileo processor w/ Meyer Remote Monitoring System (RMS), analog 1/3 octave EQ if required (BSS FCS960) Mix Position: Center of Main Floor (45' from Down Stage Edge) On Stage Audio Power: 12 x 30 Amp circuits DAYTIME SOUND CURFEW 3:00 PM, MON – FRI, NO EXCEPTIONS. Lighting Summary: Down Stage (FOH): 60' Truss with 48 x 750W ETC Source 4 Pars loaded with narrow lenses (all lenses available), 2 audience blinders and 8 x 19° 750W Source 4 ERS Up Stage: 48' Truss with 48 x 750W ETC Source 4 Pars loaded with narrow lenses (12 w/ Color Scrollers), 2 audience blinders and 7 x 26° 750W Source 4 ERS w/ Iris Miscellaneous: 12 x 750W ETC Source 4 Pars for Floor Lighting, etc. and 1 x 750W Source 4 ERS (any lens but 19°) Console: High End Systems Road Hog w/2 mini-wings, and Hog PC for backup Dimmers: 144 Spot Lights: 4 x Lycian Xenon 1290XLT 2k House Light Control: ETC SmartFade 12/96 DMX (Stage Right, House Operated) Total House Blackout: Yes, except emergency and aisle lighting Intercom: 8 station Clear-Com system Hazer: 1 x Reel FX DF-50 Hazer with fan
WARFIELD - MONITOR SYSTEM and STAGE EQUIPMENT
1 Yamaha PM5D
8 Meyer USM-16 Meyer UM-12 Meyer MSL-22 Meyer 650-R24 Meyer MSL-32 Meyer 650-R2
9 Meyer / Crest6 Meyer / Crest2 Meyer / Crest4 Meyer / Crest
1 Ultra Sound 48 channel4 Ultra Sound 15 channel Stage Boxes
1 AKG D-1121 Electro-Voice RE-204 Electro-Voice EV-4083 Audio Technica AT-236 Sennheiser MD-4214 AKG C-4512 Shure SM-812 Shure Beta-52 Dynamic Microphone1 Shure Beta-916 Shure Beta-98
10 Shure SM-578 Shure SM-584 Shure Beta-58
12 Countryman DI Boxes Active1 Quad DI 4 channel DI Active
11
10
48 mono, 4 stereo Digital Console
1x 15" Conventionally Powered Monitor*1x 12" Conventionally Powered Monitor**1x 15" Conventionally Powered Drum Fills*2x 18" Conventionally Powered Drum Subs****Conventionally Powered Side Fills***2x 18" Conventionally Powered Subs****
S-1 Amplification*M-1 Amplification**M-3 Amplification***B-1 Amplification****
Stage Box Split
Condenser Microphone
Condenser Microphone
Dynamic MicrophoneDynamic MicrophoneDynamic MicrophoneDynamic Microphone
Assortment of Tall + Short Mic StandsAssortment of Long + Short XLR Cable2 Circuit Quad Edison Power Boxes
Condenser MicrophoneDynamic MicrophoneDynamic MicrophoneDynamic Microphone
Dynamic MicrophoneCondenser Microphone
WARFIELD - FRONT of HOUSE and OUTBOARD EQUIPMENT
1 Yamaha PM5D
22 Meyer MILO Self Powered PA System 11 per side11 Meyer HP-700 Self Powered Subs 4 per side, 3 flown center2 Meyer MSL-4 Self Powered Front Fill 1 per side4 Meyer CQ-1 Self Powered Front Fill 2 per side6 Meyer M1D Self Powered Delay Fills under balcony
1 BSS FCS-960 Stereo 1/3 oct EQ's1 Meyer Galileo 616 Drive System
1 TC Electronics TC2290 Digital Delay Unit1 TC Electronics M5000 Dual Engine Reverb Effects Unit1 Yamaha SPX990 Reverb Effects Unit
1 Sony L3 Compact Disc Player1 Tascam CD-R Compact Disc Recorder
48 mono, 4 stereo Digital Console
LD:
DB: RR
Date:
Plate 1 of 1
Show:
Scale: 1/4" = 1' Even
CL
19°
26°
ETC Source4 19° ERS @ 750W
ETC Source4 26° ERS @ 750W
ETC Source4 Par EA NSP @ 750W
ProCan 4Light Blinder2 Cir. @ 1300W Ea.
ChromaQ
Key
L138
A137
R136
B135
W134
M133
L103
A104
R105
B106
W107
M108
L144
A143
R142
B141
W140
M139
L97
A98
R99
B100
W101
M102
M132
W131
B130
R129
A128
L127
M109
W110
B111
R112
A113
L114
M126
W125
B124
R123
A122
L121
M115
W116
B117
R118
A119
L120
19°
145
19°
149
19°
150
19°
148
19°
146
19°
147
House Gel 9/13/12
19°
151
19°
152
153, 154 155, 156
L18
S17
A16
R15
B14
S13
W31
L32
S33
A34
R35
B36
S12
B11
R10
A9
S8
L7
B37
R38
A39
S40
L41
W42
26°
52
26°
51
26°
53
26°
50
26°
54
26°
49
205
204 206 207 209
208
26°
64
S25
L26
A27
R28
S29
B30
201 203
L24
A23
R22
S21
B20
W19
202W6
B5
S4
R3
A2
L1
211
B43
S44
R45
A46
L47
S48
210 212
57, 58 59, 60
C158
VNSP Special forHouse Right Booth DJ
Notes:Positions and Symbols not drawn to scaleLamp Bars are mounted inside pre-rig, and cannot moveUS Truss is centered 27' US of DS edge of stageUS Truss is hung 6" SR of CenterDS Truss is centered 20' 9" DS of DS edge of stageTrims are called by Tour LD (DS Truss has limitation on how low it can be,
based on sight lines, speaker coverage, and followspot shot)Source4 Pars in FOH & US Truss are NSP 750WAll Source4 Lekos are 750W and overhung on top rail of trussConsole: Roadhog w/ mini wingsBackup Console: HogPC w/ mini wingHazer: DF50 + fan, controlled from stageHose Snake: (5) 5-Pin DMX (1 needed for house rig), (2) 3-Pin
XLR Com Lines, (2) CAT-V Lines, (1) 20A Eddison
US Truss
FOH Truss
4 Lycian 1290XLTFollowspots
House Color:1-x33 - Pink2-L106 - Red3-L132 - Blue4-L180 - Lav5-L126 - Magenta6-L205 - 1/2 CTO
(8) cans R-L106 (8) cans L-L180 (4) cans W-N/C(8) cans B-L119 (8) cans A-x22 (12) S-ChromaQ
(8) cans R-L106 (8) cans L-L180 (8) cans W-N/C (1) can C-L707(8) cans B-L119 (8) cans A-x22 (8) cans M-L126
ChromaQ Colors:1-N/C, 2-L179, 3-L778, 4-L106, 5-L328, 6-L126, 7-L180, 8-L707, 9-L181, 10-L119,11-L141, 12-L161,13-L116, 14-L124, 15-L139, 16-L101, 17-L147, 18-L201, 19-L204
V7
Upstage (SR to SL) Blue – L119 – 8k 20, 30, 14, 36, 37, 11, 43, 5 Red – L106 – 8K 22, 28, 15, 35, 38, 10, 45, 3 Lavender – L180 – 8k 24, 26, 18, 32, 41, 7, 47, 1 Amber – x22 – 8k 23, 27, 16, 34, 39, 9, 46, 2 Open White – N/C – 4k 19, 31, 42, 6 Color Faders # Dim Scroller (1ch) 1 25 201 2 21 202 3 29 203 4 17 204 5 33 205 6 13 206 7 12 207 8 40 208 9 8 209 10 44 210 11 4 211 12 48 212 Lekos – 49, 50, 51, 64, 52, 53, 54 US Moles – 57, 58, 59, 60
House Rig Quick Patch Downstage (SR to SL) Blue – L119 – 8k 117, 124, 111, 130, 106, 135, 100, 141 Red – L106 – 8K 118, 123, 112, 129, 105, 136, 99, 142 Lavender – L180 – 8k 120, 121, 114, 127, 103, 138, 97, 144 Magenta – L126 – 8k 115, 126, 109, 132, 108, 133, 102, 139 Amber – x22 – 8k 119, 122, 113, 128, 104, 137, 98, 143 Open White – N/C – 8k 116, 125, 110, 131, 107, 134, 101, 140 Lekos – 145, 146, 147, 151, 152, 148, 149, 150 DS Moles – 153, 154, 155, 156 House Right Booth DJ Special – L707– 1k VNSP – 158
400AmpsUpstage Truss and Tour Lighting
200Amps IsoAudio
200AmpsFOH Truss & Auxiliary Power
(Located in SR Organ Loft50' from Stage)
USDimmers
(Through 50' 4/0 Turned Cams*)
*
Snake Pit150' to FOH
6-22-2011Groundplan - Power
Scale: 1/8" = 1' Even DB: RR
DRIVING DIRECTIONS TO THE WARFIELD THEATRE Stage Door / Load In: 26 Taylor Street, SF CA 94102
FROM I-80/Bay Bridge
1. I-80 Westbound 2. Take the 5th St exit on the left 3. Slight left at Harrison St 4. Take the 1st right onto 6th St 5. Continue onto Golden Gate Ave/Taylor St 6. Turn right at Taylor St 7. Destination will be on the right
FROM US-101 NORTH
1. US-101 Northbound 2. Slight right at I-80 E 3. Take the exit toward US-101 N 4. Merge onto 7th St 5. Turn right at Stevenson St 6. Take the 1st left onto 6th St 7. Continue onto Golden Gate Ave/Taylor St 8. Turn right at Taylor St 9. Destination will be on the right
FROM US-101 SOUTH
1. US-101 Southbound 2. Right at Van Ness Ave 3. Turn left at Golden Gate Ave 4. Turn left at Taylor St 5. Destination will be on the right
WARFIELD RESERVED PARKING MAP
Parking Area #1: Fits (1) 53’ truck and (1) bus no trailer, or equivalent. Bus pulls all the way up to the red at parking lot, truck pulls up to bus bumper.
Parking Area #2: IS NOT AVAILABLE when the Golden Gate Theatre is open, which is not often.
Parking Area #3:
Parking Area #4: Generators are OK if they are not blowing into the Pizza Parlor - we MUST be aware and considerate of our neighbor.
ALL OTHER VEHICLES MUST PARK OFFSITE. NO GENERATORS ALLOWED IN FRONT OF OUR NEIGHBORING BUSINESSES AT ANY TIME.
2
1
3
4
PARKING RESTRICTIONS
TAYLOR ST.
Warfield side ‐‐ No Parking 6:00‐8:00am Tues/Thurs/Sun ‐ street sweeping*
Golden Gate side ‐‐ No Parking 6:00‐8:00am Mon/Wed/Fri/Sat ‐ street sweeping*