329
ventilation and cmv
Guide created by France Air 2010 – All rights reserved. www.france-air.com
Défumair® XTA 2smoke extraction casing fan with transmission F400-120
- Three-phase 400 / 650 V - 50 Hz / 60 Hz - 1 speed 2 or 4 poles from 5,5 kW to 30 kW.
- Three-phase 400 V - 50 Hz - 2 speeds 4/8 poles Dahlander coupling from 0,60 kW to 28 kW or 2/4 poles from 0,80 to 8 kW.
➤� options• Personalisation :
- Padlockable on/off switch with return position contact.- Differential pressostat assembled and aeraulically connected - Suction and discharge flange.- horizontal suction/ vertical discharge
or vertical suction/ horizontal discharge or vertical suction/horizontal discharge (prices consult us).
- Motorisation 2 speeds 4/6 poles, independant wiring (consult us).
• Défumair® XTA 2 Protection Pack : - Defumair® XTA 2 associatated to the relay box Ordinys® 3 or
Ordinys® Soft Start (relay box with gradual start-up). - The protection pack is a ready to use offer. It includes all
wiring operations between the fan and the relay box with padlockable switch and pressostat.
- 3 versions exist : Pack smoke extraction alone, Pack smoke extraction External comfort, Pack smoke extraction Ordinys® Soft Start.
- Simplified installation. Saves time. - Respecting the security rules : cables comply to the NFS
61-932 normes, installation rules of fire security systems (SSI).
➤� packaging• Self-supporting structure.
➤� limits of use• Conveyed fluid maximum temperature : 100 °C.
• Interior and exterior installation with adapted accessories.
➤� specifications• Extraction casing fan, accreditied F400-120, made in galvanised
steel with access doors and panels to make maintenance and starting up easier. It will be equipped with a forward curved turbine with double inlet connected to the motor by pulley-belt transmission. The motor will be located outside the air flow.
• Type Défumair® XTA 2, France Air brand.
➤� advantages• Optimum performances.
• Modularity : 4 versions possibles.
• Monobloc construction
• Personalised offer : pressostat assembled and connected, padlockable on/off switch, protection pack.
➤� range• Range composed of 11 models (turbines Ø 225 to 710 mm) with
4 new sizes (Ø 225, 250, 315 and 450 mm).
• Flow from 2 000 to 55 000 m3/h.
• Motorisation : 4 new powers (1,1 kW in 2 poles, 9,2 kW in 2 or 4 poles and 15 kW in 4 poles)
• Modularity : 4 versions possibles
- Horizontal suction /horizontal discharge : version HH
- Horizontal suction / vertical discharge : version HV
- Vertical suction / horizontal discharge : version VH - Vertical suction / vertical discharge : version VV
➤� designationDéfumair® XTA 2 450 4 P T 0,75 kW Name Transmission Size Polarity Three-phase Motorisation forward turbine
application• Smoke extraction IGH and ERP.
• General clean air ventilation.
➤� construction• Casing :
- In galvanised steel sheets reinforced by longitudinal and transvers Oméga profiles.
- Access door to the motorfan group starting from size 500 for all versions.
- Connecting of the structure done by setting.
• Motor support : - In galvanised steel sheet.
- System with runners to adjust the belt tension.
• Turbine : - Type forward curved centrifugal with double inlet,
in galvanised steel, dynamically balanced. - Connection to motor by transmission. - Easy adjusting of the belt tension.
• Transmission : - By internal pulley-belt, out of the air flow. - Pulley driving variable 1 or 2 grooves, up to 9,2 kW. - Fixed pulley in steel 1, 2, 3 or 4 grooves with removable core. - Trapezoïd belts type SPA or SPB. - Easy adjusting of the belt tension.• Motorisation : - Motor with feet B3, IP 55 - Classe F. - Service S1. - Three-phase 230 / 400 V - 50 Hz / 60 Hz 1 speed 2 or 4 poles
from 0,55 kW to 4 kW.
Relay box Ordinys® 3 or Ordinys Soft Start
with padlockable switche+ pressostat with fireproof cable
and pressure tube for aeraulic connection
Rain visor for Ordinys® for exterior installation (included in
the pack)
de
fum
air
® xta 2
330
ventilation and cmv
www.france-air.com Guide created by France Air 2010. All rights reserved.
ventilation and cmv
➤� �Dimensions and weight
technical description
• Version HH : horizontal suction / horizontal discharge
fi re grading / CE label• Accredited Comfort- Smoke extraction.• F400-120 approval : extraction at 400 °C during 2 hours according to the EN 12101-3 norm.• Compliance certifi cate CE delivered by the CTICM.
• Version HV : horizontal suction / vertical discharge
Suction view Lateral view transmission side
Discharge view Lateral viewside opposite to transmission
View from above
Suction view Lateral view transmission side
Front view Lateral viewside opposite to transmission
Discharge view (from above)
de
fum
air
® x
ta 2
331
ventilation and cmv
Guide created by France Air 2010 – All rights reserved. www.france-air.com
➤� Dimensions and weight
technical description
• Version VH : vertical suction / horizontal discharge
• Version VV : vertical suction / vertical discharge
Suction view (from below)
Lateral view transmission side
Discharge view (front)Rear view Lateral viewside opposite to transmission
View from above
side opposite to transmission
Suction view ( from below)
Lateral view transmission side
Front viewRear view Lateral viewside opposite to transmission
Discharge view (above)
side opposite to transmission
de
fum
air
® xta 2
332
ventilation and cmv
www.france-air.com Guide created by France Air 2010. All rights reserved.
ventilation and cmv
➤� � Dimensions and weight
technical description
A B C E F G H I Weight(without motor)
225 770 555 1 005 480 600 555 200 280 88
250 855 625 1 060 550 670 590 220 315 112
280 955 705 1 150 630 750 650 245 355 131
315 1 040 750 1 240 675 835 700 275 400 151
355 1 145 820 1 320 740 935 745 310 450 171
400 1 270 880 1 540 810 1 045 870 350 500 224
450 1 380 930 1 650 850 1 165 960 395 560 254
500 1 525 1 010 1 800 930 1 295 1 030 440 630 324
560 1 670 1 090 1 960 1 015 1 445 1 120 490 710 366
630 1 875 1 215 2 115 1 140 1 635 1 210 550 800 507
710 2 100 1 370 2 310 1 295 1 835 1 310 625 900 592
Dimensions in mm
➤� �Arrangements and transmission position for each version
View from abovetransmission on the right
H-H RightH-H Right H-V Right V-V Right V-H Right
View from abovetransmission on the left
H-H Left H-V Left V-V Left V-H Left
Lateral view
H-V V-V V-HH-H H-V V-V V-H
de
fum
air
® x
ta 2
333
ventilation and cmv
Guide created by France Air 2010 – All rights reserved. www.france-air.com
technical description
➤� Electric features
Motor 4 poles400 V
kW 0,55 0,75 1,10 1,50 2,20 3,00 4,00
Nominal I (A)
1,42 1,86 2,61 3,34 4,75 6,47 8,18
Weight (kg) 13 14 19 20 26 29 42
kW 5,50 7,50 9,20 11,00 15,00 18,50 22,00 30,00
Nominal I (A)
11 14,80 17,80 22,10 29,10 35,10 41,00 56,00
Weight (kg) 55 69 70 96 123 172 173 233
Motor 4/8 poles (Dahlander)
400 V
kW 0,60/0,15 0,80/0,20 1,20/0,30 1,60/0,40 2,20/0,55 2,80/0,70 3,80/1,0
Nominal I (A)
1,76/0,76 1,99/0,88 2,92/1,29 3,80/1,69 4,84/2,00 6,01/2,41 8,26/2,75
Weight (kg) 15 15 20 23 31 32 43
kW 5,00/1,30 7,20/1,80 11,00/3,00 14,00/3,50 17,00/4,30 20,00/5,00 28/6,50
Nominal I (A)
10,40/3,50 14,40/4,64 21,00/7,00 26,50/8,45 33,40/12,70 38,60/14,10 52,00/18,00
Weight (kg) 67 80 119 135 162 177 235
Motor 2 poles400 V
kW 1,10 1,50 2,20 3,00 4,00 5,50 7,50 9,20
Nominal I(A)
2,50 3,28 4,58 5,96 7,81 10,50 14,20 17,40
Weight (kg) 14 19 21 29 40 55 67 69
Motor 2/4 poles (Dahlander)
400 V
kW 1,10/0,25 1,50/0,37 2,20/0,50 3,10/0,80 4,40/1,10 6,OO/1,50 8,00/2,00
Nominal I (A)
2,41/0,75 3,54/1,25 4,63/1,54 6,20/1,99 8,59/2,79 11,40/3,67 15,30/4,83
Weight (kg) 15 20 22 33 43 58 67
de
fum
air
® xta 2
334
ventilation and cmv
www.france-air.com Guide created by France Air 2010. All rights reserved.
ventilation and cmv
selection example : graph Défumair® XTA 2
DÉFUMAIR® XTA 2-250
Flow (m3/h) 700 1 500 2 300 3 100 3 900 4 700
Dynamic pressure (Pa) 1 6 15 26 42 61
Additional pressure drop version HV, VH and VV (Pa)
3 13 31 56 88 128
Selection example : To select : Flow Q = 4 700 m3/h. Static pressure = 500 Pa
(static pressure calculated on the network).
➤� Fan installed with free discharge or ducted discharge (H-H) (point A)
The graphs being in total pressure, for the fl ow (4 700 m3/h), you must add the corresponding dynamic pressure (see chart ) : 61 Pa, hence the total pressure : Pt = Pd + Pst ➔ �Pt = 61 + 500 = 561 Pa.The functioning features of the fan are then defi nied by :the rotation speed = 1 450 rpm, the motor power = 3 kW.
➤� Fan in horizontal suction vertical discharge version (HV),or vertical suction vertical discharge (VV), or vertical suction horizontal discharge (VH) (point B)
The graphs being in total pressure for the version HH, for the fl ow you need 4 700 m3/h, calculate the total pressure for this version. Then, add the pressure drop for the other versions : for Q = 4 700 m3/h PdC = 128Then, for the versions with horizontal suction vertical discharge or vertical suction vertical discharge or vertical suction horizontal discharge :- Point B : Pt (other versions) = Pt (HH) + PdC = 561 + 128 = 689 Pa.
Rotation speed = 1 600 rpm. Motor power = 3 kW.
The tests are carried out according to the AMCA 210-99 norm.
A
689 B
560
All functioning zones presented are zones with certifi cate for smokeextraction 400°/2 h.
Flow in m3/h
Total pressure of fans in pascal (Pa)
Turbine rotation speed
Installed motor power
Chart to go from total pressure to static pressure
Motor 4 polesMotor 2 poles
DÉFUMAIR® XTA 2-250
Flow (m3/h) 5 500 6 300 7 100 7 900 9 500
Dynamic pressure (Pa) 83 109 139 171 248
Additional pressure drop version HV, VH and VV (Pa)
175 229 291 361 522
Your 5 reading parameters :
de
fum
air
® x
ta 2
335
ventilation and cmv
Guide created by France Air 2010 – All rights reserved. www.france-air.com
selection graph Défumair® XTA 2-225
DÉFUMAIR® XTA 2-225
Flow (m3/h) 700 1 200 1 700 2 200 2 700 3 200 3 700 4 200 4 700 5 200
Dynamic pressure (Pa) 2 5 11 18 27 38 51 66 83 102
Additional pressure drop version HV, VH et VV (Pa) 4 12 23 39 59 83 111 143 179 219
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
Motor 4 polesMotor 2 poles
These graphs correspond to the horizontal suction and discharge version HH : for other versions, add the additional pressure drop version HV, VH and VV.
de
fum
air
® xta 2
336
ventilation and cmv
www.france-air.com Guide created by France Air 2010. All rights reserved.
ventilation and cmv
selection graph Défumair® XTA 2-250
DÉFUMAIR® XTA 2-250
Flow (m3/h) 700 1 500 2 300 3 100 3 900 4 700 5 500 6 300 7 100 7 900
Dynamic pressure (Pa) 1 6 15 26 42 61 83 109 139 171
Additional pressure drop version HV, VH and VV (Pa) 3 13 31 56 88 128 175 229 291 361
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
Motor 4 polesMotor 2 poles
These graphs correspond to the horizontal suction and discharge version HH : for other versions, add the additional pressure drop version HV, VH and VV.
de
fum
air
® x
ta 2
337
ventilation and cmv
Guide created by France Air 2010 – All rights reserved. www.france-air.com
selection graph Défumair® XTA 2-280
DÉFUMAIR® XTA 2-280
Flow (m3/h) 1 900 2 800 3 700 4 600 5 500 6 400 7 300 8 200 9 100 10 000
Dynamic pressure (Pa) 7 14 25 39 55 75 98 123 152 183
Additional pressure drop version HV, VH et VV (Pa) 15 32 55 86 122 166 216 272 335 405
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
Motor 4 polesMotor 2 poles
These graphs correspond to the horizontal suction and discharge version HH : for other versions, add the additional pressure drop version HV, VH and VV.
de
fum
air
® xta 2
338
ventilation and cmv
www.france-air.com Guide created by France Air 2010. All rights reserved.
ventilation and cmv
selection graph Défumair® XTA 2-315
DÉFUMAIR® XTA 2-315
Flow (m3/h) 1 000 2 500 4 000 5 500 7 000 8 500 10 000 11 500 13 000 14 500
Dynamic pressure (Pa) 1 8 20 38 61 90 125 165 211 263
Additional pressure drop version HV, VH and VV (Pa) 2 14 35 66 106 157 217 287 366 456
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
Motor 4 polesMotor 2 poles
These graphs correspond to the horizontal suction and discharge version HH : for other versions, add the additional pressure drop version HV, VH and VV.
de
fum
air
® x
ta 2
339
ventilation and cmv
Guide created by France Air 2010 – All rights reserved. www.france-air.com
selection graph Défumair® XTA 2-355These graphs correspond to the horizontal suction and discharge version HH : for other versions, add the additional pressure drop version HV, VH and VV.
Totalpressure
Flow
Motor 4 polesMotor 2 poles de
fum
air
® xta 2
DÉFUMAIR® XTA 2-355
Flow (m3/h) 900 2 500 4 100 5 700 7 300 8 900 10 500 12 100 13 700 15 300
Dynamic pressure (Pa) 1 5 12 28 46 69 96 127 163 203
Additional pressure drop version HV, VH and VV (Pa) 1 9 25 49 80 119 166 220 282 352
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
340
ventilation and cmv
www.france-air.com Guide created by France Air 2010. All rights reserved.
ventilation and cmv
selection graphs Défumair® XTA 2-400
DÉFUMAIR® XTA 2-400
Flow (m3/h) 2 700 4 500 6 300 8 100 9 900 11 700 13 500 15 300 17 100 18 900
Dynamic pressure (Pa) 4 10 20 33 49 68 91 117 146 178
Additional pressure drop version HV, VH et VV (Pa) 6 18 34 57 85 119 158 203 254 310
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
Motor 4 poles
These graphs correspond to the horizontal suction and discharge version HH : for other versions, add the additional pressure drop version HV, VH and VV.
de
fum
air
® x
ta 2
341
ventilation and cmv
Guide created by France Air 2010 – All rights reserved. www.france-air.com
selection graph Défumair® XTA 2-450
DÉFUMAIR® XTA 2-450
Flow (m3/h) 3 400 5 500 7 600 9 700 11 800 13 900 16 000 18 100 20 200 22 300
Dynamic pressure (Pa) 4 10 19 30 45 62 82 105 131 160
Additional pressure drop version HV, VH and VV (Pa) 7 17 33 54 80 112 148 189 236 287
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection
Motor 4 poles
These graphs correspond to the horizontal suction and discharge version HH : for other versions, add the additional pressure drop version HV, VH et VV.
de
fum
air
® xta 2
342
ventilation and cmv
www.france-air.com Guide created by France Air 2010. All rights reserved.
ventilation and cmv
selection graph Défumair® XTA 2-500
DÉFUMAIR® XTA 2-500
Flow (m3/h) 3 800 6 300 8 800 11 300 13 800 16 300 18 800 21 300 23 800 26 300
Dynamic pressure (Pa) 3 9 17 29 43 60 80 102 128 156
Additional pressure drop version HV, VH et VV (Pa) 6 17 32 53 79 111 147 189 236 288
Note :graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
Motor 4 poles
These graphs correspond to the horizontal discharge and suction verions HH : for other versions, add the additional pressure drop version HV, VH and VV.
de
fum
air
® x
ta 2
343
ventilation and cmv
Guide created by France Air 2010 – All rights reserved. www.france-air.com
selection graph Défumair® XTA 2-560
DÉFUMAIR® XTA 2-560
Flow (m3/h) 4 600 8 000 11 400 14 800 18 200 21 600 25 000 28 400 31 800 35 200
Dynamic pressure (Pa) 3 10 20 34 51 72 96 124 155 190
Additional pressure drop version HV, VH et VV (Pa) 6 18 38 63 96 135 181 233 292 358
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
Motor 4 poles
These graphs correspond to the horizontal discharge and suction verions HH : for other versions, add the additional pressure drop version HV, VH and VV.
de
fum
air
® xta 2
344
ventilation and cmv
www.france-air.com Guide created by France Air 2010. All rights reserved.
ventilation and cmv
selection graph Défumair® XTA 2-630
DÉFUMAIR® XTA 2-630
Flow (m3/h) 4 000 9 000 14 000 19 000 24 000 29 000 34 000 39 000 44 000 49 000
Dynamic pressure (Pa) 2 8 20 38 60 88 121 159 202 251
Additional pressure dropversion HV, VH and VV (Pa) 3 16 40 73 117 170 234 308 392 486
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
Motor 4 poles
These graphs correspond to the horizontal suction and discharge version HH : for other versions, add the additional pressure drop version HV, VH and VV.
de
fum
air
® x
ta 2
345
ventilation and cmv
Guide created by France Air 2010 – All rights reserved. www.france-air.com
selection graph Défumair® XTA 2-710
DÉFUMAIR® XTA 2-710
Flow (m3/h) 6 400 12 000 17 600 23 200 28 800 34 400 40 000 45 600 51 200 56 800
Dynamic pressure (Pa) 3 10 21 37 57 82 111 144 181 223
Additional pressure drop version HV, VH and VV (Pa) 6 21 45 78 120 171 231 301 379 466
Note : graphs drawn for 1 speed motors. For 2 speed motors do the high speed selection.
Motor 4 poles
These graphs correspond to a horizontal suction and discharge version HH : for other versions, add the additional pressure drop version HV, VH and VV.
de
fum
air
® xta 2
346
ventilation and cmv
www.france-air.com Guide created by France Air 2010. All rights reserved.
ventilation and cmv
accessories
➤� �Differential pressostat 20 to 300 Pa
• The pressostat enables the launching of the fi lter clogging alarm by an increase of differential pressure or a fan default alarm by decrease of the differential pressure.
• Assembly accessories delivered with device :- 1 attachement bracket + screw for assembly on water duct.- 2 fast connections.- 1 plastic tube length 2 m.- Box IP 54.
➤� �Antivibration mountings Type “BCA” :• These supports are made of two fl at and parallel grids linked
by a rubber crown.
Type “PAR” :• The PAR types are shock absorbers with steel springs,
with frame in light metal and cast for antivibration assembly and acoustic isolation
➤� �Padlockable on/off switch
• Three-phase 400 V – 1 or 2 speeds.• IP 65 with position contact.
➤� � Rain visor discharge and rectangular fl exible sleeve
• To assemble at discharge, for casings installed outside.• They are equipped with an antivolatile netting.
➤� Suction and discharge fl anges for direct connection to network
• Discharge • Discharge
Models Dimensions (mm)A B
225 555 200250 590 220280 650 245315 700 275355 745 310400 870 350450 960 395500 1 030 440560 1 120 490630 1 200 550710 1 310 625
Models Dimensions (mm)A B
225 600 480250 600 549280 746 630315 833 675355 932 740400 1 043 806450 1 165 850500 1 295 930560 1 445 1 015630 1 635 1 140710 1 835 1 290
• Suction
Models Dimensions (mm)A B C D E
225 557 200 513,5 160 160250 589 220 549 180 170280 650 245 610 205 180315 700 275 660 235 200355 745 310 705 270 215400 868 350 828 310 235450 959 395 918,5 355 255500 1 028 440 988 400 280560 1 122 490 1 082 450 300630 1 212 550 1 172 510 330710 1 312 625 1 342 585 390
• Visor
• Sleeve
ModelsFlexible sleeve discharge
(mm)Flexible sleeve suction (mm)
A B C D E A B C D E225 557 200 607 250
60/100
599 480 649 530
60/100
250 589 220 639 270 666 548 716 598280 650 245 700 295 740 630 790 680315 700 275 750 325 833 675 883 725355 745 310 795 360 932 740 982 790400 868 350 919 400 1 043 806 1 193 856450 959 395 1 009 445 1 165 850 1 215 900500 1 028 440 1 078 490 1 295 930 1 345 980560 1 122 490 1 172 540 1 445 1 115 1 495 1 165630 1 212 550 1 262 600 1 634 1 140 1 684 1 190710 1 312 625 1 362 725 1 835 1 290 1 885 1 340
de