20
GRUNDFOS DATA BOOKLET Vaccuperm VGS-140 High-performance disinfection systems

Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Embed Size (px)

Citation preview

Page 1: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

GRUNDFOS DATA BOOKLET

Vaccuperm VGS-140High-performance disinfection systems

Page 2: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ta

ble

of c

on

ten

ts

2

Vaccuperm VGS-140

1. General 3Vaccuperm VGS-140 high-performance disinfection systems 3

2. Functional scheme 4Functional scheme Vaccuperm VGS-141, VGS-143, VGS-145 4

3. Technical data 5Vaccuperm VGS-141, VGS-143, VGS-145 gas dosing systems 5Vaccuperm VGS-147 and VGS-148 vacuum regulators 7

4. Accessories 8High-capacity injectors 545 8Combined liquid chlorine trap and chlorine gas filter LiquFilt 524 9Liquid gas evaporator RV 171 10Change-over device 185 12Change-over device 185-2 with bypass 13Vacuum change-over device 186 15Pressure reducing valves 544 17

5. Further product documentation 18WebCAPS 18WinCAPS 19

Page 3: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ge

ne

ral

Vaccuperm VGS-140 1

1. General

Vaccuperm VGS-140 high-performance disinfection systems• Pressure sensors for more safety: optional pressure

sensors for injector vacuum and operating vacuum allow the early detection of disturbances such as insufficient injector vacuum or vacuum regulator faults.

• Precise scan system for the flowmeter: the inductive sensor is insensitive to soiling and does not get into contact with the aggressive gas to be dosed. The resolution of the signal is about 2 % of the limit value of the measuring range.

• Systems with direct proportional control: the servomotor of the rate valve can optionally be equipped with electronics (4-20 mA input) for direct proportional control without additional control electronics.

• Automation of the dosing process: optionally a microprocessor-based controller can be integrated for PID control or for compound loop control.

• Ergonomic and service-friendly design: all control elements and displays are installed at eye-level for easy handling. Easy change-over from automatic to manual operation. All assembly and service work can be executed with a few standard tools.

Note: Vaccuperm VGS-140 are expert systems. All component configurations must be adapted to the requirements on site. For assistance, please ask our product specialists or project department.

Fig. 1 Complete installation: drinking water disinfection with chlorine gas

TM

04

13

40

27

09

16

18

16

2 3b

4

5

11a

14

16

11 1012

13

16

15

17

987

6

3c3a

Pos. Description

1 Chlorine drum

1a Chlorine drum balance

2Control for the pneumatic chlorine drum quick-action stop valves

3 Chlorine drum lifting device

3a Lifting beam

3b Spring balance for cranes

3c Chain hoist

4 Automatic change-over device

5 Nitrogen rinsing device

6 Chlorine evaporator

7 Pressure reducing valve and filter

8 Vacuum regulator VGS-141 to VGS-148

9 Gas dosing system VGS-141 to VGS-145

10 High-capacity injector

11 Motive water booster pump

12 Flowmeter with 4-20 mA output

13 Injection unit

14 Chlorine gas sensor

15 Optical and acoustic alarm devices

16 Suction nozzle to the chlorine gas neutralization system

17 Central control panel with computer interface

18 Sprinkling system

Pos. Description

3

Page 4: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Fu

nc

tion

al s

ch

em

e

4

Vaccuperm VGS-1402

2. Functional scheme

Functional scheme Vaccuperm VGS-141, VGS-143, VGS-145

Fig. 2 Functional scheme Vaccuperm VGS-141, VGS-143, VGS-145

TM

04

14

01

39

09

Front hood with swinging-out clear screen

Option: microprocessor-based PID controller

Option: servomotor with or without control electronics

Linear rate valve

Vacuum meterOption: with limit contacts

Gas flowmeter Option: 4-20 mA scanning

Option: sensor for operating vacuum

Enclosure with foot for floor mounting or without foot for wall mounting

High capacitiy injector

Vacuum regulatorVGS-148 with safety

valveOption: contact

manometer

Differential pressureregulator

Option: with sensor forinjector vacuum

Page 5: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Te

ch

nic

al

da

ta

Vaccuperm VGS-140 3

3. Technical data

Vaccuperm VGS-141, VGS-143, VGS-145 gas dosing systems• Vacuum dosing system with rate valve

• Material: Polyurethane (enclosure), PVC, PTFE, FKM, silver-coated nickel-chrome alloy

• Gas flowmeter according to floater principle

• Vacuum meter NG 100 mm

• Manual or automatic adjustment of the dosing flow

• Differential pressure regulator

• Floor mounting unit, covered

• For ammonia and sulphur dioxide on request

Dimensions

Fig. 3 VGS-141, VGS-143, VGS-145 with foot for floor mounting

TM

04

13

41

27

09

1000

610 390

45050

DN

40=

730

1810

1000

DN

20=

760

5

Page 6: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Te

ch

nic

al d

ata

6

Vaccuperm VGS-1403

Technical data

Options

Vacuum connections

• For PE hose 8/11, PE hose 12/16, PE hose 1/2", PVC pipe 12/16, PVC pipe 15/20

Motor

Synchronous motor 3VA, IP55, actuating time 0-100 %: 90 s at 50 Hz, 75 s at 60 Hz, installed on the rate valve

• 230 V (50/60 Hz) with feedback potentiometer

• 115 V (50/60 Hz) with feedback potentiometer

• 230 V (50/60 Hz), input/output 4-20 mA

• 115 V (50/60 Hz), input/output 4-20 mA

Magnetic inductive gas flow sensor

• Precise scanning for all measuring tubes from 2 to 200 kg/h

Vacuum meter for injector vacuum

• NG 100 with 2 limit contact outputs

• Without vacuum meter

Pressure sensors

• For injector vacuum

• For operating vacuum

• For injector and operating vacuum, signal evaluation via external PLC, required control voltage 24 V

Enclosure versions

• Floor mounting unit with hood, open foot

• Wall mounting unit with hood

Spare parts sets

Flow rate Vacuum connections Type

50-1000 g/h

PE hose 10/14 VGS-141-010

100-2000 g/h

200-4000 g/h

400-8000 g/h

0.5 - 10 kg/h

1-20 kg/hPVC pipe 20/25 VGS-143-040

2-40 kg/h

3.5 - 70 kg/h

PVC pipe 40/50 VGS-145-2006-120 kg/h

10-200 kg/h

Dosing medium For dosing unit Order No.

Chlorine gas

VGS-141-010up to 500 g/h

96729331

VGS-141-0101000 g/h up to 10 kg/h

96688759

VGS-143-04010 kg/h up to 40 kg/h

96688761

VGS-145-20040 kg/h up to 200 kg/h

96088763

Page 7: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Te

ch

nic

al

da

ta

Vaccuperm VGS-140 3

Vaccuperm VGS-147 and VGS-148 vacuum regulators• For line installation, with integrated safety valve,

with grooved flange DN 25 (G 1) without liquid trap

• For ammonia and sulphur dioxide on request.

Dimensions

Fig. 4 VGS-147 vacuum regulator

Fig. 5 VGS-148 vacuum regulator

Technical data

Options

Manometer

• 0-16 bar, NG 63, optionally with MIN contact (N.O./N.C.)

• Without manometer

Testing agents

• Bottle with ammonia for tightness check

Spare parts setsT

M0

4 1

31

2 2

60

9T

M0

4 1

31

3 2

60

9

209

52

Ø 1

75

128

171

106

DN 25

20/25

20612540/50

Ø 5

0

245

245

7

170

170

DN 25

6/8

Flow rate Vacuum connection Type

Max. 40 kg/h PVC pipe 20/25 VGS-147-040

Max. 70 kg/h PVC pipe 40/50 VGS-148-070

Max. 120 kg/h PVC pipe 40/50 VGS-148-120

Max. 200 kg/h PVC pipe 40/50 VGS-148-200

Spare parts set for Order No.

VGS-147-040 96688764

VGS-148-070 96688765

VGS-148-120 96688766

VGS-148-200 96688767

7

Page 8: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

orie

s

8

Vaccuperm VGS-1404

4. Accessories

High-capacity injectors 545The selection of the injector to be used for the specific task determines the safe functioning of the entire chlorine gas system. The important criteria are the motive water pressure and counterpressure as well as the dosing capacity. The indication of the customer data and the operating point are necessary for the decision.

• Due to the special form of the nozzle, the operating costs are low and efficiency is improved.

• Easy selection of the operating point thanks to the optimum graduation of the product range.

• The construction according to the flow allows a reduction of the pressure losses of the non-return diaphragm valve.

• A safety non-return diaphragm valve according to the floater principle protects the dosing unit disposed upstream optimally from the entry of water or chlorine solution.

• Injectors for ammonia and sulphur dioxide are available on request.

Dimensions

Fig. 6 High-capacity injector 545

Technical data

TM

04

13

34

26

09

D2

D1

H

D1

L

Dosing capacity

Counterpres-sure[bar]

Length (L)[m]

Height (H)

[mm]

Motive water connection

(D1)

Vacuum connection(D2)

Chlorine solution connection

(D1)Product No.

10 kg/h 0.5 - 3 400 155 PVC pipe 25/32 PE hose 10/14 PVC pipe 25/32 96696669

10 kg/h 0.5 - 3 400 155 Hose NPT 1 1/4" PE hose 10/14 Hose NPT 1 1/4" 91836339

10 kg/h 3-7 400 155 PVC pipe 25/32 PE hose 10/14 PVC pipe 25/32 96729173

10 kg/h 3-7 400 155 Hose NPT 1 1/4" PE hose 10/14 Hose NPT 1 1/4" 96729205

20 kg/h 0.5 - 3 480 190 PVC pipe 32/40 PVC pipe 20/25 PVC pipe 32/40 96729067

20 kg/h 3-7 480 190 PVC pipe 32/40 PVC pipe 20/25 PVC pipe 32/40 96706388

40 kg/h 0.5 - 3 710 310 PVC pipe 50/63 PVC pipe 20/25 PVC pipe 50/63 96729072

40 kg/h 3-7 710 310 PVC pipe 50/63 PVC pipe 20/25 PVC pipe 50/63 91836631

70 kg/h 0.5 - 3 650 325 PVC pipe 65/75 PVC pipe 40/50 PVC pipe 65/75 96729139

70 kg/h 3-7 650 325 PVC pipe 65/75 PVC pipe 40/50 PVC pipe 65/75 96729225

120 kg/h 0.5 - 3 720 325 PVC pipe 80/90 PVC pipe 40/50 PVC pipe 80/90 96729141

120 kg/h 3-7 720 325 PVC pipe 80/90 PVC pipe 40/50 PVC pipe 80/90 96729228

200 kg/h 0.5 - 3 825 370 PVC pipe 90/110 PVC pipe 40/50 PVC pipe 90/100 96729122

200 kg/h 3-7 825 370 PVC pipe 90/110 PVC pipe 40/50 PVC pipe 90/100 96729211

Page 9: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

ori

es

Vaccuperm VGS-140 4

Combined liquid chlorine trap and chlorine gas filter LiquFilt 524LiquFilt 524 separates the impurities in the gaseous chlorine and catches any liquid chlorine drops.

LiquFilt 524 is an important part of high-capacity chlorine gas dosing systems. It protects the downstream dosing units from damage by liquid chlorine and prevents the obstruction of nozzles and valve seats. Essential parts of the unit are a rugged steel vessel filled with chlorine-proof mineral filter material, and an electric heater strip wrapped around its casing. The self-regulating strip conveys the heat to the steel and thus keeps the housing at a constant temperature, hot enough to evaporate the deposited liquid chlorine drops.

LiquFilt 524 is installed directly in the chlorine gas line via its flange connections.

The tube connection needs not to be detached for exchanging the filter. In order not to interrupt the chlorine gas supply when exchanging the filter, we recommend the installation of a bypass line with three shut-off valves.

Dimensions

Fig. 7 LiquFilt 524

Technical data

Types

Accessories

Spare parts

TM

04

13

31

26

09

Max. flow 200 kg/h chlorine gas

Nominal pressure 16 bar

Test pressure 23 bar

Nominal heating capacity

80 W at 10 °C

Materialhigh-grade seamless steel, Rockwool gasket, asbestos-free material

Input groove flange DN 25 (G1), DIN 2527/2512

Output tongue flange DN 25 (G1), DIN 2527/2512

Weight 22 kg

290

49

0~

190

130

Description Type

LiquFilt trap and filter with heather strip 115 V or 230 V (50/60 Hz)

524-205

Description Product No.

Steel pipe, G 1/2, DIN 2441, 1 m, ∅21.3 96727447

Steel pipe, G 1, DIN 2441, 1 m, ∅33.7 96727448

Pair of welding neck flanges DN 25, PN 16, groove and tongue, DIN 2633/2512

96698366

Pair of threaded flanges G 1, PN 16, groove and tongue, DIN 2566/2512

96727563

Reducing part G 1 to G 1/2 96727557

Description Product No.

Spare parts for LiquFilt 524 91835919

9

Page 10: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

orie

s

10

Vaccuperm VGS-1404

Liquid gas evaporator RV 171The automatic evaporator transforms the liquid gas taken from the storage tank by heating. The heat transfer medium is either water containing anticorrosive and antifreezer, or oil.

The liquid gas to be vapourized flows under pressure into the lower part of the evaporator, passes preheating, evaporating and progressive heating zone and leaves it as a dry saturated gas flow at the top. In order to protect the downstream installations up to the pressure reducing valve from reliquefaction of the gas, the evaporator is designed generously, considering the gas outlet temperature.

A bursting disk with connected expansion tank ensures that the highest admissible operating pressure is not exceeded. This tank is dimensioned in a way to transform the overpressure after the bursting of the bursting disk into the normal operating pressure. If the bursting disk bursts, this is indicated by a contact manometer.

A contact manometer with two adjustable limit contacts indicates too high or too low gas pressure.

• The compact and maintenance-free multitubular heat exchanger is designed for the evaporation of liquid chlorine yet also suitable for ammonia and sulphur dioxide.

• Chlorine quantities of up to 200 kg/h can be evaporated at temperatures from 5 °C to 60 °C (water) or 68 °C to 72 °C (oil)

• Protection from overheating and overpressure

• High operational safety due to the use of proven materials resistant against the dosing media.

Dimensions

Fig. 8 Liquid gas evaporator RV 171W

Technical data

Types

TM

04

13

14

26

09

~ 730

14

1293

DN 25

DN 25

203

1805

~ 670

125

100

Power consumption 9 kW (171-100), 18 kW (171-200)

Voltage 230/400 V (50/60 Hz)

Weightapprox. 220 kg, including load section and control panel

Max. operating pressure

12 bar, with bursting disk 16 bar

Testing pressure 33 bar

Admissible ambient temperature

0-40 °C

Warming-up time approx. 4 minutes (water), 5-7 minutes (oil)

Connection inlet groove flange DN 25 (G 1), DIN 2635/2512

Connection outlet tongue flange DN 25 (G 1), DIN 2635/2512

Heat transfer medium Evaporation capacity Type

Water100 kg/h 171W-100

200 kg/h 171W-200

Oil100 kg/h 171-100

200 kg/h 171-200

Page 11: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

ori

es

Vaccuperm VGS-140 4

Selection

Voltage of heating elements

• 230/400 V (50/60 Hz)

• 240/415 V (50/60 Hz)

• 220/380 V (50/60 Hz)

Voltage of circulation pump

• 220-240 V (50 Hz), IP42/F

• 220-240 V (60 Hz), IP42/F

Voltage of control panel

• Load section: 380-415 V (50/60 Hz), with supply for gas pressure reducing valve

• Control section: 24 V DC, options: digital display unit, Profibus DP.

Accessories

Spare parts sets

Functional scheme RV 171W-100, -200

Fig. 9 Evaporator RV 171W-100, -200

Functional scheme RV 171-100, -200

Fig. 10 Evaporator RV 171-100, -200

Description Product No.

Shut-off valve DN 25 (G 1), inlet and outlet side, full-way valve chlorine and ammonia

96706446

Flange set: pair of counterflanges (threaded flanges), G 1, PN 16, DIN 2566/2512, with screws and sealings

96727563

Flange set: pair of counterflanges (welding neck flanges), DN 25, PN 16, DIN 2633/2512, with screws and sealings

96698366

Description Product No.

Spare parts set: bursting disk 16 bar, copper line for contact manometer

95705524

Gasket set: gaskets for heating elements, flat gaskets for inlet and outlet connection, gaskets for bursting disk and pipe connections

96688864

TM

04

13

36

26

09

1 Heat exchanger 6 Bursting disk

2 Liquid chlorine intake 7 Expansion vessel

3 Gas outlet 8Filler neck for the heat transfer medium (water)

4 Heating elements 9 Equalizing tank

5 Circulation pump 10 Drain valve

TM

04

14

03

26

09

1 Tank 5 Agitator

1a Tubular bundle 6 Bursting disk

1b Thermal oil 7 Expansion tank

2 Inlet connection 8Contact manometer behind the bursting disk

3 Outlet connection 9Contact manometer (operation manometer)

4 Heating flange 10 Contact thermometer

6

3

7

1

2

9

4

8

5

10

4

2

1

3

10 5 8

1a1b

76

9

11

Page 12: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

orie

s

12

Vaccuperm VGS-1404

Change-over device 185The change-over device is installed between two gas container batteries to ensure an uninterrupted gas supply. It automatically changes over from the empty battery to the full standby battery.

• Application: liquid or gaseous chlorine under pressure.

• Reliable change-over function due to the two independent motor valves with manual operation in case of power failure.

• Overload-proof single-phase AC motors for valve actuation.

• Practically no leakage losses thanks to the PTFE packings of the stuffing boxes.

• High functional safety and resistance to wear and tear thanks to the materials resistant against the dosing media.

• Indication of the switching status of the valves with control lamps.

• Transmission of the operating status via a potential-free changeover contact.

Dimensions

Fig. 11 Change-over device 185-1 without bypass

TM

04

13

15

26

09

180

100

275

75

384 160

867

124

Page 13: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

ori

es

Vaccuperm VGS-140 4

Change-over device 185-2 with bypassThe change-over device 185-2 with bypass allows manual operation during maintenance of the servomotors. Opening and closing of the motor valves is made in manual operation with electrical pushbuttons.

Dimensions

Fig. 12 Change-over device 185-2 with bypass

Fig. 13 Control panel for 185

TM

04

13

16

26

09

1170

475110 475 110

493

39634

0

18010

0

TM

04

13

17

26

09

445

400

227

300

Ø9

200

230

420

37

13

Page 14: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

orie

s

14

Vaccuperm VGS-1404

Technical data

Types

Options

Flow

• Up to 200 kg/h chlorine gas, up to 600 kg/h liquid chlorine

Voltages

• Control panel and motor valves 230 V (50 Hz), IP65

• Control panel and motor valves 230 V (60 Hz), IP65

• Control panel and motor valves 115 V (60 Hz), IP65

• Control panel and motor valves 115 V (50 Hz), IP65

• Without control panel, motor valves 230 V (50/60 Hz)

• Without control panel, motor valves 115 V (60 Hz)

Accessories

Functional scheme

Fig. 14 Change-over device 185

Nominal pressure 16 bar

Testing pressure 23 bar

Connection inletgroove flange DN 25 (G 1)/PN16, DIN 2527/2512

Connection outlettongue flange DN 25 (G 1)/PN16, DIN 2527/2512

Material

valve body and flanges:

steel

valve balls: stainless steel

gaskets: PTFE, glass-fibre reinforced

lines:seamless drawn steel tube to DIN EN10255

Protection IP65

Actuating time 0-100 % 15 sec. at 50 Hz, 12.5 sec. at 60 Hz

Outputs3 potential-free outputs; max. charge: 250 V AC, 10 A / 250 V DC, 1 A

Power consumption 0.1 kW

Weight185-1: approx. 20 kg

185-2: approx. 30 kg

Admissible ambient temperature

0 to +40 °C

Description Type

Change-over device without bypass, 2 motor valves, contact manometer, control panel 230 V (50 Hz)

185-1

Change-over device with bypass with shut-off valves, 2 motor valves, contact manometer, control panel 230 V (50 Hz)

185-2

Description Product No.

Set of threaded flanges DN 25 (G 1)/PN16, connection flange DIN 2566/2512

96727576

Gasket set: gaskets for groove-and tongue flanges 96688979

TM

04

14

02

40

09

1 Drum balance 3 Change-over device 185

2 Chlorine drum 4 Control panel

1

34

2

WIWIWIWI

P P

Page 15: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

ori

es

Vaccuperm VGS-140 4

Vacuum change-over device 186The vacuum change-over device is controlled via the control panel by two contact manometers and automatically changes over from the empty battery to the full standby battery.

• Application: chlorine gas under vacuum.

• The change-over device consists of a 3-way ball valve, an electric servomotor and a control panel.

• At the inlet side, it is connected to two vacuum regulators; at the outlet side it is connected to a dosing unit.

• Both contact manometers are mounted either directly at the vacuum regulators or at the end of the header line before the vacuum regulators.

Dimensions

Fig. 15 Vacuum change-over device 186

TM

04

13

37

26

09

30

50

190

138

132

Ø40

Ø86

187

232

>111

95

45

100

62

145

15

Page 16: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

orie

s

16

Vaccuperm VGS-1404

Dimensions control panel

Fig. 16 Control panel for 186

Technical data

Options

Connections

• PVC pipe 32/40

• PVC pipe 40/50, extensions

• PVC pipe 20/25, reductions

Voltage of control panel

• 115 V or 230 V (50/60 Hz)

Fastening material

• for wall mounting

Labelling of the control panel

• German

• English

• French

• Spanish

Types

Spare parts

Functional scheme 186

Fig. 17 Functional scheme 186

TM

04

13

19

26

09

Maximum flow up to 120 kg Cl2 per hour

Servomotor

protection: IP65

actuating time 0-100 %: 4 seconds

admissible ambient temperature:

0 to +40 °C

admissible storage temperature:

-10 to +50 °C

weight: 2 kg

Control panelprotection: IP54

weight: 8.5 kg

Description Type

Vacuum change-over device with control panel 230 V (50/60 Hz)

186-120

Description Product No.

Maintenance kit: ball valve without servomotor for 186-120

95720552

227

400

420

300

440

Ø8.5

TM

04

13

20

26

09

A Line from the containers E Control panel

B Line to the dosing unit F Vacuum regulator

CChange-over device 186-120

GOverpressure line to the absorption tank

D Pressure reducing valve H LiquFilt 524

A

CD D EFF

H H

GG

A

B

Page 17: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Ac

ce

ss

ori

es

Vaccuperm VGS-140 4

Pressure reducing valves 544• The pressure reducing valve 544 reduces the

unregulated gas pressure of the gas containers to a constant operation pressure.

• It ensures the precise and pressure-independent functioning of the inlet valve of the vacuum regulator and prevents re-liquefaction of the gas.

• If the reducing valve is additionally equipped with a servomotor, it protects the dosing unit against the penetration of liquefied gas by its immediate shut-off function in case of malfunctions of the system.

• If the operating pressure exceeds the setpoint value, the spring-cone-diaphragm system causes the valve to close.

• If the pressure reducing valve 544 is connected to a Conex DIA-G or DIS-G gas warning system, the valve will be immediately closed in case of a gas breakout.

Dimensions

Fig. 18 Pressure reducing valve without servomotor (above), with servomotor (below)

Technical data

Order data

Suitable flanges see accessories below.

Options

Pressure reducing valves with servomotor

Servomotor: linear-attached actuator with no-voltage readjusting device, closing time approx. 5.5 s (at max. stroke), setting time 100 %, admissible ambient temperature 0 to +50 °C, protection IP54

• 230 V, 50 Hz, 22 mA, 20 W

• 115 V, 60 Hz, 60 mA, 21.6 W.

Accessories

Spare parts sets

TM

04

13

33

26

09

Connection H D L1 L2 T1 T2 Type

G 1/2 200 120 198 240 128 240 544-101

G 1 220 150 240 - 128 255 544-102

G 1/2 425 120 198 240 128 240 544-210

G 1 435 150 240 - 128 255 544-220

H

162

H~3

5

D

L 2

L 1 T 2

T 1

Nominal pressure 16 bar

Counterpressure adjustable 2 to 3 bar

Weight

6 kg G 1/2, without servomotor

12.5 kg G 1, without servomotor

9.5 kg G 1/2, with servomotor

16 kg G 1, with servomotor

Materials

diaphragm: fine silver

valve cone: tantal

valve seat: PVDF

spring: nickel-chrome alloy, silver plated

O-rings: FKM

enclosure: brass

Max. flow

Diameter Connection Servomotor Product No.

40 kg/h DN 15 G 1/2

- 96693065

230 V50/60 Hz

96729024

115 V50/60 Hz

96729025

200 kg/h DN 25 G 1

- 96729019

230 V50/60 Hz

96729028

115 V50/60 Hz

96729031

Description Product No.

Manometer 0 to 16 bar, G 1/4 (only for chlorine) 96688685

Wall mounting bracket, steel 96728842

Connection set for copper pipe 6/8 (only G 1/2) 96727550

Pair of threaded flanges (connection flange), groove and tongue, DN 15

96727553

Set of threaded flanges (counter flange), groove and tongue, DN 15, with screws and sealings

96727556

Pair of threaded flanges (connection flange), groove and tongue, DN 25

96706818

Set of threaded flanges (counter flange), groove and tongue, DN 25, with screws and sealings

96727563

Description Product No.

Spare parts set for valve type 544-101, -210 96688978

Spare parts set for valve type 544-102, -220 91835913

17

Page 18: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Fu

rthe

r pro

du

ct d

oc

um

en

tatio

n

18

Vaccuperm VGS-1405

5. Further product documentation

WebCAPSWebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com.

WebCAPS contains detailed information on more than 220,000 Grundfos products in more than 30 languages.

Information in WebCAPS is divided into six sections:

• Catalogue

• Literature

• Service

• Sizing

• Replacement

• CAD drawings.

Catalogue

Based on fields of application and pump types, this section contains the following:• technical data• curves (QH, Eta, P1, P2, etc.) which can be adapted to the

density and viscosity of the pumped liquid and show the number of pumps in operation

• product photos• dimensional drawings• wiring diagrams• quotation texts, etc.

Literature

This section contains all the latest documents of a given pump, such as• data booklets• installation and operating instructions• service documentation, such as Service kit catalogue and

Service kit instructions• quick guides• product brochures.

Service

This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps.Furthermore, the section contains service videos showing you how to replace service parts.

Page 19: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

Fu

rth

er

pro

du

ct

do

cu

me

nta

tio

n

Vaccuperm VGS-140 5

WinCAPS

Fig. 19 WinCAPS DVD

WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 220,000 Grundfos products in more than 30 languages.

The program contains the same features and functions as WebCAPS, but is an ideal solution if no internet connection is available.

WinCAPS is available on DVD and updated once a year.

Sizing

This section is based on different fields of application and installation examples and gives easy step-by-step instructions in how to size a product:• Select the most suitable and efficient pump for your

installation.• Carry out advanced calculations based on energy,

consumption, payback periods, load profiles, life cycle costs, etc.

• Analyse your selected pump via the built-in life cycle cost tool.• Determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section, it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:• .dxf, wireframe drawings• .dwg, wireframe drawings.

3-dimensional drawings:• .dwg, wireframe drawings (without surfaces)• .stp, solid drawings (with surfaces)• .eprt, E-drawings.

0 1

Subject to alterations.

19

Page 20: Vaccuperm VGS-140 - Grundfosnet.grundfos.com/Appl/WebCAPS/Grundfosliterature-2965250.pdf · Vaccuperm VGS-140 high-performance disinfection systems • Pressure sensors for more safety:

GRUNDFOS A/S . DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00www.grundfos.com

The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

Being responsible is our foundationThinking ahead makes it possible

Innovation is the essence

95719030 0812

ECM: 1062502