2
8
5
4
5
4
6
5
4
9
3
1
10
14
5
12
15
5
12
1
10
11
1
12
4
7
13
3/8 in
[10 mm]
3/8 in
[10 mm]
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH SHADOWLINE ANGLE
4
DX/DXL GRID - SL EDGE (CAST) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH MAIN TEE
2
DX/DXL GRID - SL EDGE (CAST) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH WALL ANGLE
1
DX/DXL GRID - SL EDGE (CAST) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID WITH SQUARE-CUT PANEL
6
DX/DXL GRID - SL EDGE (CAST) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH CROSS TEE
5
DX/DXL GRID - SL EDGE (CAST) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID AND PANEL AT WALL ANGLE
3
DX/DXL GRID - SL EDGE (CAST) - CROSS TEE ELEVATION
5
12
6
2
1
OPTIONAL INSTALLATION: SQUARE-CUT AND
ENCAPSULATE EDGE AT PERIMETER.
PREFERRED INSTALLATION: PROFILE EDGE OF PANEL TO BE SHOWN AT
REVEAL MOLDING. FIELD-CUT AND ROUT EDGE TO MATCH IF NECESSARY.
USG Corporation
550 West Adams Street
Chicago, IL 60661 USA
WWW.USG.com
T. 800-USG4YOU
ISSUE RECORD:
REV: DATE:
SHEET INFORMATION:
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.
USG SL EDGE
DX / DXL GRID
SC3124
00 21/02/201701 12/04/2017
USG BASIC GRID DETAILS (NON SEISMIC)
DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)
DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)
KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON
SECTION CUT THROUGH MAIN TEE.CORTE DE TEE PRINCIPAL.SECTION COUPÉE PAR TÉE PRINCIPAL.
1
2
4
5
6
7
ATTACH WALL ANGLE AT CEILING PERIMETER.
ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.
TEE SECUNDARIA.TÉE SECONDAIRE.
FIJAR ANGULO PERIMETRAL AL MURO.
8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
CROSS TEE.
CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.
9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.
10SHADOW MOLDING.ANGULO PERIMETRAL.PROFILÉ MURALE.
12MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.
13SECTION CUT THROUGH CROSS TEE.CORTE DE TEE SECUNDARIA.SECTION COUPÉE PAR TÉE SECONDAIRE.
14FIELD-CUT MAIN TEE AT WALL ANGLE.
COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
15SQUARE-CUT PANEL AT PERIMETER (OPTIONAL INSTALLATION).
DISCOURS - DÉTAILS DU PLAFOND DE BASE
AJUSTE EN PLAFON PERIMETRAL (INSTALACION OPCIONAL).PANNEAU À BORD CARRÉ AU PÉRIMÈTRE ( INSTALLATION FACULTATIVE).
CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.
ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.
REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.
ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.
ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.
ADDITIONAL NOTES:
1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.
3
11
2
8
5
4
5
4
6
5
4
9
3
1
10
14
5
12
15
5
12
1
10
11
1
12
4
7
13
3/8 in
[10 mm]
3/8 in
[10 mm]
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH SHADOWLINE ANGLE
4
DX/DXL GRID - SL EDGE (HALCYON) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH MAIN TEE
2
DX/DXL GRID - SL EDGE (HALCYON) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH WALL ANGLE
1
DX/DXL GRID - SL EDGE (HALCYON) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID WITH SQUARE-CUT PANEL
6
DX/DXL GRID - SL EDGE (HALCYON) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH CROSS TEE
5
DX/DXL GRID - SL EDGE (HALCYON) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID AND PANEL AT WALL ANGLE
3
DX/DXL GRID - SL EDGE (HALCYON) - CROSS TEE ELEVATION
5
12
6
2
1
OPTIONAL INSTALLATION: SQUARE-CUT AND
ENCAPSULATE EDGE AT PERIMETER.
PREFERRED INSTALLATION: PROFILE EDGE OF PANEL TO BE SHOWN AT
REVEAL MOLDING. FIELD-CUT AND ROUT EDGE TO MATCH IF NECESSARY.
USG Corporation
550 West Adams Street
Chicago, IL 60661 USA
WWW.USG.com
T. 800-USG4YOU
ISSUE RECORD:
REV: DATE:
SHEET INFORMATION:
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.
USG SL EDGE
DX / DXL GRID
SC3125
00 21/02/201701 12/04/2017
USG BASIC GRID DETAILS (NON SEISMIC)
DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)
DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)
KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON
SECTION CUT THROUGH MAIN TEE.CORTE DE TEE PRINCIPAL.SECTION COUPÉE PAR TÉE PRINCIPAL.
1
2
4
5
6
7
ATTACH WALL ANGLE AT CEILING PERIMETER.
ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.
TEE SECUNDARIA.TÉE SECONDAIRE.
FIJAR ANGULO PERIMETRAL AL MURO.
8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
CROSS TEE.
CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.
9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.
10SHADOW MOLDING.ANGULO PERIMETRAL.PROFILÉ MURALE.
12MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.
13SECTION CUT THROUGH CROSS TEE.CORTE DE TEE SECUNDARIA.SECTION COUPÉE PAR TÉE SECONDAIRE.
14FIELD-CUT MAIN TEE AT WALL ANGLE.
COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
15SQUARE-CUT PANEL AT PERIMETER (OPTIONAL INSTALLATION).
DISCOURS - DÉTAILS DU PLAFOND DE BASE
AJUSTE EN PLAFON PERIMETRAL (INSTALACION OPCIONAL).PANNEAU À BORD CARRÉ AU PÉRIMÈTRE ( INSTALLATION FACULTATIVE).
CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.
ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.
REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.
ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.
ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.
ADDITIONAL NOTES:
1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.
3
11
2
8
5
4
5
4
6
5
4
9
3
1
10
14
5
12
15
5
12
1
10
11
1
12
4
7
13
3/8 in
[10 mm]
3/8 in
[10 mm]
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH SHADOWLINE ANGLE
4
DX/DXL GRID - SL PE EDGE (PEDESTALS ECLIPSE) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH MAIN TEE
2
DX/DXL GRID - SL PE EDGE (PEDESTALS ECLIPSE) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH WALL ANGLE
1
DX/DXL GRID - SL PE EDGE (PEDESTALS ECLIPSE) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID WITH SQUARE-CUT PANEL
6
DX/DXL GRID - SL PE EDGE (PEDESTALS ECLIPSE) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH CROSS TEE
5
DX/DXL GRID - SL PE EDGE (PEDESTALS ECLIPSE) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID AND PANEL AT WALL ANGLE
3
DX/DXL GRID - SL PE EDGE (PEDESTALS ECLIPSE) - CROSS TEE ELEVATION
5
12
6
2
1
OPTIONAL INSTALLATION: SQUARE-CUT AND
ENCAPSULATE EDGE AT PERIMETER.
PREFERRED INSTALLATION: PROFILE EDGE OF PANEL TO BE SHOWN AT
REVEAL MOLDING. FIELD-CUT AND ROUT EDGE TO MATCH IF NECESSARY.
USG Corporation
550 West Adams Street
Chicago, IL 60661 USA
WWW.USG.com
T. 800-USG4YOU
ISSUE RECORD:
REV: DATE:
SHEET INFORMATION:
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.
USG SL PEDESTALS EDGE
DX / DXL GRID
SC3127
00 21/02/201701 12/04/2017
USG BASIC GRID DETAILS (NON SEISMIC)
DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)
DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)
KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON
SECTION CUT THROUGH MAIN TEE.CORTE DE TEE PRINCIPAL.SECTION COUPÉE PAR TÉE PRINCIPAL.
1
2
4
5
6
7
ATTACH WALL ANGLE AT CEILING PERIMETER.
ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.
TEE SECUNDARIA.TÉE SECONDAIRE.
FIJAR ANGULO PERIMETRAL AL MURO.
8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
CROSS TEE.
CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.
9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.
10SHADOW MOLDING.ANGULO PERIMETRAL.PROFILÉ MURALE.
12MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.
13SECTION CUT THROUGH CROSS TEE.CORTE DE TEE SECUNDARIA.SECTION COUPÉE PAR TÉE SECONDAIRE.
14FIELD-CUT MAIN TEE AT WALL ANGLE.
COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
15SQUARE-CUT PANEL AT PERIMETER (OPTIONAL INSTALLATION).
DISCOURS - DÉTAILS DU PLAFOND DE BASE
AJUSTE EN PLAFON PERIMETRAL (INSTALACION OPCIONAL).PANNEAU À BORD CARRÉ AU PÉRIMÈTRE ( INSTALLATION FACULTATIVE).
CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.
ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.
REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.
ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.
ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.
ADDITIONAL NOTES:
1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.
3
11
2
8
5
4
5
4
6
5
4
9
3
1
10
14
5
12
15
5
12
1
10
11
1
12
4
7
13
3/8 in
[10 mm]
3/8 in
[10 mm]
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH SHADOWLINE ANGLE
4
DX/DXL GRID - SLB EDGE (CAST) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH MAIN TEE
2
DX/DXL GRID - SLB EDGE (CAST) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH WALL ANGLE
1
DX/DXL GRID - SLB EDGE (CAST) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID WITH SQUARE-CUT PANEL
6
DX/DXL GRID - SLB EDGE (CAST) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH CROSS TEE
5
DX/DXL GRID - SLB EDGE (CAST) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID AND PANEL AT WALL ANGLE
3
DX/DXL GRID - SLB EDGE (CAST) - CROSS TEE ELEVATION
5
12
6
2
1
OPTIONAL INSTALLATION: SQUARE-CUT AND
ENCAPSULATE EDGE AT PERIMETER.
PREFERRED INSTALLATION: PROFILE EDGE OF PANEL TO BE SHOWN AT
REVEAL MOLDING. FIELD-CUT AND ROUT EDGE TO MATCH IF NECESSARY.
USG Corporation
550 West Adams Street
Chicago, IL 60661 USA
WWW.USG.com
T. 800-USG4YOU
ISSUE RECORD:
REV: DATE:
SHEET INFORMATION:
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.
USG SLB EDGE
DX / DXL GRID
SC3128
00 21/02/201701 12/04/2017
USG BASIC GRID DETAILS (NON SEISMIC)
DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)
DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)
KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON
SECTION CUT THROUGH MAIN TEE.CORTE DE TEE PRINCIPAL.SECTION COUPÉE PAR TÉE PRINCIPAL.
1
2
4
5
6
7
ATTACH WALL ANGLE AT CEILING PERIMETER.
ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.
TEE SECUNDARIA.TÉE SECONDAIRE.
FIJAR ANGULO PERIMETRAL AL MURO.
8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
CROSS TEE.
CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.
9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.
10SHADOW MOLDING.ANGULO PERIMETRAL.PROFILÉ MURALE.
12MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.
13SECTION CUT THROUGH CROSS TEE.CORTE DE TEE SECUNDARIA.SECTION COUPÉE PAR TÉE SECONDAIRE.
14FIELD-CUT MAIN TEE AT WALL ANGLE.
COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
15SQUARE-CUT PANEL AT PERIMETER (OPTIONAL INSTALLATION).
DISCOURS - DÉTAILS DU PLAFOND DE BASE
AJUSTE EN PLAFON PERIMETRAL (INSTALACION OPCIONAL).PANNEAU À BORD CARRÉ AU PÉRIMÈTRE ( INSTALLATION FACULTATIVE).
CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.
ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.
REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.
ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.
ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.
ADDITIONAL NOTES:
1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.
3
11
2
8
5
4
5
4
6
5
4
9
3
1
10
14
5
12
15
5
12
1
10
11
1
12
4
7
13
3/8 in
[10 mm]
3/8 in
[10 mm]
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH SHADOWLINE ANGLE
4
DX/DXL GRID - SLT EDGE (WET-FORMED) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH MAIN TEE
2
DX/DXL GRID - SLT EDGE (WET-FORMED) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH WALL ANGLE
1
DX/DXL GRID - SLT EDGE (WET-FORMED) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID WITH SQUARE-CUT PANEL
6
DX/DXL GRID - SLT EDGE (WET-FORMED) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH CROSS TEE
5
DX/DXL GRID - SLT EDGE (WET-FORMED) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID AND PANEL AT WALL ANGLE
3
DX/DXL GRID - SLT EDGE (WET-FORMED) - CROSS TEE ELEVATION
5
12
6
2
1
OPTIONAL INSTALLATION: SQUARE-CUT AND
ENCAPSULATE EDGE AT PERIMETER.
PREFERRED INSTALLATION: PROFILE EDGE OF PANEL TO BE SHOWN AT
REVEAL MOLDING. FIELD-CUT AND ROUT EDGE TO MATCH IF NECESSARY.
USG Corporation
550 West Adams Street
Chicago, IL 60661 USA
WWW.USG.com
T. 800-USG4YOU
ISSUE RECORD:
REV: DATE:
SHEET INFORMATION:
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.
USG SLT EDGE
DX / DXL GRID
SC3129
00 21/02/201701 12/04/2017
USG BASIC GRID DETAILS (NON SEISMIC)
DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)
DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)
KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON
SECTION CUT THROUGH MAIN TEE.CORTE DE TEE PRINCIPAL.SECTION COUPÉE PAR TÉE PRINCIPAL.
1
2
4
5
6
7
ATTACH WALL ANGLE AT CEILING PERIMETER.
ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.
TEE SECUNDARIA.TÉE SECONDAIRE.
FIJAR ANGULO PERIMETRAL AL MURO.
8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
CROSS TEE.
CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.
9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.
10SHADOW MOLDING.ANGULO PERIMETRAL.PROFILÉ MURALE.
12MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.
13SECTION CUT THROUGH CROSS TEE.CORTE DE TEE SECUNDARIA.SECTION COUPÉE PAR TÉE SECONDAIRE.
14FIELD-CUT MAIN TEE AT WALL ANGLE.
COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
15SQUARE-CUT PANEL AT PERIMETER (OPTIONAL INSTALLATION).
DISCOURS - DÉTAILS DU PLAFOND DE BASE
AJUSTE EN PLAFON PERIMETRAL (INSTALACION OPCIONAL).PANNEAU À BORD CARRÉ AU PÉRIMÈTRE ( INSTALLATION FACULTATIVE).
CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.
ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.
REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.
ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.
ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.
ADDITIONAL NOTES:
1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.
3
11
2
8
5
4
5
4
6
5
4
9
3
1
10
14
5
12
15
5
12
1
10
11
1
12
4
7
13
3/8 in
[10 mm]
3/8 in
[10 mm]
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH SHADOWLINE ANGLE
4
DX/DXL GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH MAIN TEE
2
DX/DXL GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH WALL ANGLE
1
DX/DXL GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID WITH SQUARE-CUT PANEL
6
DX/DXL GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH CROSS TEE
5
DX/DXL GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID AND PANEL AT WALL ANGLE
3
DX/DXL GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - CROSS TEE ELEVATION
5
12
6
2
1
OPTIONAL INSTALLATION: SQUARE-CUT AND
ENCAPSULATE EDGE AT PERIMETER.
PREFERRED INSTALLATION: PROFILE EDGE OF PANEL TO BE SHOWN AT
REVEAL MOLDING. FIELD-CUT AND ROUT EDGE TO MATCH IF NECESSARY.
USG Corporation
550 West Adams Street
Chicago, IL 60661 USA
WWW.USG.com
T. 800-USG4YOU
ISSUE RECORD:
REV: DATE:
SHEET INFORMATION:
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.
USG SLT EDGE
DX / DXL GRID
SC3130
00 21/02/201701 12/04/2017
USG BASIC GRID DETAILS (NON SEISMIC)
DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)
DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)
KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON
SECTION CUT THROUGH MAIN TEE.CORTE DE TEE PRINCIPAL.SECTION COUPÉE PAR TÉE PRINCIPAL.
1
2
4
5
6
7
ATTACH WALL ANGLE AT CEILING PERIMETER.
ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.
TEE SECUNDARIA.TÉE SECONDAIRE.
FIJAR ANGULO PERIMETRAL AL MURO.
8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
CROSS TEE.
CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.
9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.
10SHADOW MOLDING.ANGULO PERIMETRAL.PROFILÉ MURALE.
12MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.
13SECTION CUT THROUGH CROSS TEE.CORTE DE TEE SECUNDARIA.SECTION COUPÉE PAR TÉE SECONDAIRE.
14FIELD-CUT MAIN TEE AT WALL ANGLE.
COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
15SQUARE-CUT PANEL AT PERIMETER (OPTIONAL INSTALLATION).
DISCOURS - DÉTAILS DU PLAFOND DE BASE
AJUSTE EN PLAFON PERIMETRAL (INSTALACION OPCIONAL).PANNEAU À BORD CARRÉ AU PÉRIMÈTRE ( INSTALLATION FACULTATIVE).
CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.
ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.
REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.
ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.
ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.
ADDITIONAL NOTES:
1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.
3
11
2
8
5
4
5
4
6
5
4
9
3
1
10
14
5
12
15
5
12
1
10
11
1
12
4
7
13
3/8 in
[10 mm]
3/8 in
[10 mm]
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH SHADOWLINE ANGLE
4
DX/DXL GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH MAIN TEE
2
DX/DXL GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH WALL ANGLE
1
DX/DXL GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID WITH SQUARE-CUT PANEL
6
DX/DXL GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH CROSS TEE
5
DX/DXL GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID AND PANEL AT WALL ANGLE
3
DX/DXL GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - CROSS TEE ELEVATION
5
12
6
2
1
OPTIONAL INSTALLATION: SQUARE-CUT AND
ENCAPSULATE EDGE AT PERIMETER.
PREFERRED INSTALLATION: PROFILE EDGE OF PANEL TO BE SHOWN AT
REVEAL MOLDING. FIELD-CUT AND ROUT EDGE TO MATCH IF NECESSARY.
USG Corporation
550 West Adams Street
Chicago, IL 60661 USA
WWW.USG.com
T. 800-USG4YOU
ISSUE RECORD:
REV: DATE:
SHEET INFORMATION:
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.
USG SLT ILLUSIONS EDGE
DX / DXL GRID
SC3134
00 21/02/201701 12/04/2017
USG BASIC GRID DETAILS (NON SEISMIC)
DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)
DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)
KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON
SECTION CUT THROUGH MAIN TEE.CORTE DE TEE PRINCIPAL.SECTION COUPÉE PAR TÉE PRINCIPAL.
1
2
4
5
6
7
ATTACH WALL ANGLE AT CEILING PERIMETER.
ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.
TEE SECUNDARIA.TÉE SECONDAIRE.
FIJAR ANGULO PERIMETRAL AL MURO.
8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
CROSS TEE.
CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.
9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.
10SHADOW MOLDING.ANGULO PERIMETRAL.PROFILÉ MURALE.
12MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.
13SECTION CUT THROUGH CROSS TEE.CORTE DE TEE SECUNDARIA.SECTION COUPÉE PAR TÉE SECONDAIRE.
14FIELD-CUT MAIN TEE AT WALL ANGLE.
COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
15SQUARE-CUT PANEL AT PERIMETER (OPTIONAL INSTALLATION).
DISCOURS - DÉTAILS DU PLAFOND DE BASE
AJUSTE EN PLAFON PERIMETRAL (INSTALACION OPCIONAL).PANNEAU À BORD CARRÉ AU PÉRIMÈTRE ( INSTALLATION FACULTATIVE).
CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.
ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.
REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.
ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.
ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.
ADDITIONAL NOTES:
1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.
3
11
2
8
5
4
5
4
6
5
4
2
3
1
10
14
5
12
9
5
12
1
10
11
1
12
4
7
13
3/8 in
[10 mm]
3/8 in
[10 mm]
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH SHADOWLINE ANGLE
4
DX/DXL GRID - SQ EDGE (ALL TILES) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH MAIN TEE
2
DX/DXL GRID - SQ EDGE (ALL TILES) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FULL CEILING PANEL WITH WALL ANGLE
1
DX/DXL GRID - SQ EDGE (ALL TILES) - CROSS TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID WITH SQUARE-CUT PANEL
6
DX/DXL GRID - SQ EDGE (ALL TILES) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
PANEL AND GRID SECTION CUT THROUGH CROSS TEE
5
DX/DXL GRID - SQ EDGE (ALL TILES) - MAIN TEE ELEVATION
Scale: 6" = 1'-0"
FIELD-CUT GRID AND PANEL AT WALL ANGLE
3
DX/DXL GRID - SQ EDGE (ALL TILES) - CROSS TEE ELEVATION
5
12
6
9
1
USG Corporation
550 West Adams Street
Chicago, IL 60661 USA
WWW.USG.com
T. 800-USG4YOU
ISSUE RECORD:
REV: DATE:
SHEET INFORMATION:
DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.
USG SQ EDGE
DX / DXL GRID
SC3135
00 21/02/201701 12/04/2017
USG BASIC GRID DETAILS (NON SEISMIC)
DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)
DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)
KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON
SECTION CUT THROUGH MAIN TEE.CORTE DE TEE PRINCIPAL.SECTION COUPÉE PAR TÉE PRINCIPAL.
1
2
4
5
6
7
ATTACH WALL ANGLE AT CEILING PERIMETER.
ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.
TEE SECUNDARIA.TÉE SECONDAIRE.
FIJAR ANGULO PERIMETRAL AL MURO.
8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
CROSS TEE.
CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.
9
10SHADOW MOLDING.ANGULO PERIMETRAL.PROFILÉ MURALE.
12MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.
13SECTION CUT THROUGH CROSS TEE.CORTE DE TEE SECUNDARIA.SECTION COUPÉE PAR TÉE SECONDAIRE.
14FIELD-CUT MAIN TEE AT WALL ANGLE.
COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
DISCOURS - DÉTAILS DU PLAFOND DE BASE
CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.
ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.
REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.
REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.
ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.
ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.
ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.
ADDITIONAL NOTES:
1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.
3
11
SQUARE-CUT PANEL AT PERIMETER.AJUSTE EN PLAFON PERIMETRAL.PANNEAU À BORD CARRÉ AU PÉRIMÈTRE.