User Manual 1

USER MANUAL

VER. B

Page 2: USER MANUAL VER. B

2 User Manual

Customer Information

1. The ORBIT-6 (Model RP-206 ) complies with FCC Part 68 Rules. On the upperpanel of this product is a label that contains, among other information, the FCCRegistration Number and Ringer Equivalence Number (REN is 0.8B). If requested,this information must be provided to the Telephone Company.

2. An FCC compliant telephone connector is provided with this equipment. Thisequipment is designed to be connected to the telephone network or premiseswiring using a connector, which is Part 68 compliant.

3. If the ORBIT-6 (RP-206 ) is not operating properly, it may cause harm to thetelephone network. If so, the Telephone Company will notify you in advance that atemporary discontinuance of service may be required. If advance notice is notpractical, you will be notified as soon as possible. Also, you will be advised of yourright to file a complaint with the FCC if it is necessary.

4. The Telephone Company may make changes in its facilities, equipment,operations, or procedures, which could affect the operation of the equipment. If thishappens, the Telephone Company will provide advance notice in order to enableyou to make the necessary modifications to maintain uninterrupted service. If theequipment is causing harm to the telephone network, the Telephone Company mayrequest that the equipment be disconnected until the problem is resolved.

5. Connection to telephone company-provided coin service is prohibited. Connectionto party line service is subject to state tariffs.

6. If trouble is experienced with the ORBIT-6 (RP-206 ), for repair and warranty information, please contact your supplier.

For service centers please see back cover.

FCC Warning

This equipment has been tested and found to comply with the limits for a Class Bdigital device pursuant to Part 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmful interference in a residential installation.This equipment generates, uses, and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may cause harmfulinterference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does causeharmful interference to radio or television reception, which can be determined byturning the equipment off and on, the user is encouraged to try to correct theinterference by one or more of the following measures:

• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to which

the receiver is connected.• Consult the dealer or an experienced Radio/TV technician for help.

Changes or modifications to this unit not expressly approved by Rokonet, Ltd.,could void the user's authority to operate the equipment.

p/n: 5IN206UM B

Page 3: USER MANUAL VER. B

User Manual 3

Copyright © 2000by Rokonet Electronics Ltd.,

14 Hachoma StreetRishon Letzion 75655

Israel

All rights reserved.

No part of this document may be reproduced in any form withoutprior written permission from the publisher.

Page 4: USER MANUAL VER. B

4 User Manual

Summary of User’s CommandsThis User's Manual contains all theinformation needed to operate yourRokonet ORBIT-6 Security System and toget the most from it. This page, called aCommand Summary, is intended to giveyou brief summaries of common systemoperations. More detailed explanationsand related information can be foundwithin, by referring to the indicated page.

FUNCTION PROCEDURE MOREON

System Arming [USER CODE] + [ARM] Page 19Stay Home Arming [USER CODE] + [STAY] Page 19Instant Stay [STAY] + [STAY] Page 19System Disarming [USER CODE] Page 22Duress Disarming [DURESS CODE] Page 23Silencing an Alarm [USER CODE] Page 22Bypassing / Unbypassing aZone

[ QQ] + [ 1] + [USER CODE ] + [ ZONE NUMBER TO BEBYPASSED / UNBYPASSED]

Page 20,25

Quick Bypassing Zone [ZONE NUMBER TO BE BYPASSED] for at least 2seconds Page 25

Reset Smoke Detector(s)[ QQ ] + [ 2 ] + [USER CODE ] + [UTILITY OUTPUTNUMBER which is responsible for resetting the SmokeDetector]

Page 25

Utility Output Operation [ QQ ] + [ 2 ] + [USER CODE ] + [ UTILITY OUTPUTNUMBER ] Page 25

Display Troubles [ QQ ] + [ 3 ] Page 26,29

Display Memory [ QQ ] + [ 4 ] Page 26Setting/Changinga User Code

[ QQ ] + [ 5 ] + [MASTER CODE] + [CODE NUMBER TO BESET/CHANGED] + [NEW CODE]

Page 17,26

Set Date [ QQ ] + [ 6 ] + [ 1 ] + [MASTER CODE] + [MM] [DD] [YY] Page 26Set Time [ QQ ] + [ 6 ] + [ 2 ] + [MASTER CODE] + [H][H] [M][M] Page 26*Set Auto Arm Time [ QQ ] + [ 6 ] + [ 3 ] + [MASTER CODE] + [H][H] [M][M] Page 26Set Follow-Me Phone No. 1 [ QQ ] + [ 7 ] + [ 1 ] + [MASTER CODE] + Phone No. + [#] Page 27Set Follow-Me Phone No. 2 [ QQ ] + [ 7 ] + [ 2 ] + [MASTER CODE] + Phone No. + [#] Page 27**Set Follow-Me Phone No. 3 [ QQ ] + [ 7 ] + [ 3 ] + [MASTER CODE] + Phone No. + [ #] Page 27**Set Follow-Me Phone No. 4 [ QQ ] + [ 7 ] + [ 4 ] + [MASTER CODE] + Phone No. + [ #] Page 27Maintenance:On/Off BuzzerOn/Off Door Chime*On/Off Audible Kiss-OffIndication

[ QQ ] + [ 8 ] + [MASTER CODE] + [ 1 ][ QQ ] + [ 8 ] + [MASTER CODE] + [ 2 ][ QQ ] + [ 8 ] + [MASTER CODE] + [ 3 ]

Page 28

Get Event From Event Logger [ QQ ] + [ 9 ] + [MASTER CODE] + [EVENT NO.] Page 28Test System [ QQ ] + [ 0 ] + [MASTER CODE] Page 28

LED Trouble1 Low Battery2 AC Power Loss3 Clock/Date Not Set4 Communication Trouble

Trouble Table

5 Bell Loop Trouble

It is necessary to ARM your systemto obtain protection from intrusion.All other forms of protection,including fire and 24-hour panicalarms (i.e. police, fire, and specialemergency) are always ready toreport alarms and do NOT need tobe armed.

Page 5: USER MANUAL VER. B

User Manual 5

Table of Contents

SECTION 1: LET’S GET ACQUAINTED 7

Introduction 7

SOME DEFINITIONS 8Zone 824-Hour Zone 8Day Zone 8Central Stations 8Chimes 8Trouble Reporting 8Utility Outputs 8Key-switch 8

SECTION 2: YOUR KEYPAD 9

Visual Indicators 9

Keys 11

SECTION 3: THINGS YOU SHOULD KNOW 13

ABOUT YOUR ORBIT-6 13Arming Your System 13Full Arming and Home Arming 14Quick Arming and Code Arming 14Entry/Exit Delays 14Arming with the Front Door Open 14Sounder Cutoff 14The "Squawk" Feature 15Follow-Me Feature 15Voice Feature 15Zone Bypassing 15Duress Disarming 15Quick Bypassing and Code Bypassing 15

SECTION 4: OPERATING YOUR SYSTEM 16

Emergency Keys 16Police Emergency 16Fire Emergency 16

Page 6: USER MANUAL VER. B

6 User Manual

Special Emergency 16

User Codes 16

Setting/CHANGING THE MASTER/USER CODES 17

Deleting User Codes 18

ARMING YOUR SYSTEM 19

BYPASSING A ZONE 20Disarming an armed system 22Silencing an alarm in progress 22

Duress Disarming 23

SECTION 5: SYSTEM SOUNDS 24

SECTION 6: USER FUNCTIONS 25Zone Bypassing 25Quick Bypassing 25Extra Quick Bypassing 25Activate a Utility Output 25Reset a Smoke Detector(s) 25Display System Troubles 26Display Alarm Memory 26Add, Modify, Delete User and Master Code(s) 26Setting the Date 26Setting the Time 26Set Follow-Me Phone Number 1 27Set Follow-Me Phone Number 2 27Keypad Sounder/ Chime Operation 28Event Logger 28System Testing 28

SECTION 7: SYSTEM TROUBLES 29

Page 7: USER MANUAL VER. B

User Manual 7

Section 1: Let’s Get Acquainted

INTRODUCTION Congratulations on your purchase of Rokonet’sORBIT-6 Security System. The ORBIT-6 has beenspecifically designed to meet a wide range ofsecurity needs for many residential and smallcommercial applications.

You communicate with your ORBIT-6 through itskeypad(s). Using its keys, you can issuecommands to your system. In turn, the system cancommunicate information to you via its indicatorsand by the sounds it makes.

Your ORBIT-6 security system also consists of avariety of sensors, detectors, and contactsplaced throughout the premises and designed torecognize abnormal conditions. Typically, yoursystem protects against intrusion. Some systemsmay also have fire protection or environmentalprotection (such as gas or water level sensors)

All of your system's detectors, sensors, andcontacts are wired to the control panel. As such,your system always knows the status of anyprotected door, window, hallway, room, or area.Similarly, it knows if a smoke detector has beenactivated.

The control panel, which contains the system'selectronics and backup battery, functions in thebackground and, for purposes of security, isinstalled out of sight.

Page 8: USER MANUAL VER. B

8 User Manual

SOME DEFINITIONS There are a few terms with which you shouldbecome familiar. Knowing them will help you tobetter understand and use your system

Zone A single detector, or group of detectors, usuallyrelating to a certain area of the premises or type ofprotection. Zones that use devices designed todetect break-ins, are called intrusion zones.Another kind of zone may contain one or moreSmoke Detectors. Such zones are called firezones. An environmental zone typically protectsthe premises from gas leaks and/or flooding.

24-Hour Zone A 24-Hour intrusion zone is always armed and isusually assigned to openings which should neverbe disturbed-like fixed glass and non-movableskylights.

Day Zone A Day Zone is one in which a violation during thedisarmed period results only in a keypadannunciation. However, the same violation duringthe armed period will cause a full-fledged alarm.

Central Stations Besides producing audible alarms at yourpremises, it's likely that your system is set up to

Central Station–continually monitors the activities of many securitysystems, usually via the telephone network, and

Chimes The is a series of short keypad tones, whichcan be set up to annunciate, during the period, the violation of selected intrusion zone(s).The chime tone can be used to annunciate the

opens. The chime can be disabled enabled at

Trouble Reporting If desired, your security system may also report totroubles or malfunctions it

Utility Outputs In addition to your system's normal operation, it's

premises lighting under the control of the ORBIT-6—where it can be conveniently turned on and offfrom any system keypad, or automatically activatedin response to a system event.

Key-switch Your system may also be equipped with akeyswitch, useful for simple arming and disarmingoperations - usually at a remote location.

Page 9: USER MANUAL VER. B

User Manual 9

Section 2: Your Keypad

VISUAL INDICATORS The Orbit-6 can support 6 and 8 zone LED andLCD keypads. Both of these keypads have thesame operating procedures. This section discussesthe keypad's visual indicators and the use of itskeys.

Each keypad in yoursystem reports its statusvia its LED (lighted)indicators at the right.Through its keys, you canenter commands to "arm"and "disarm" the system,bypass intrusion zones,report emergencies,silence an alarm inprogress–along withseveral other usefulfunctions.

The four LED indicators found at the upper rightprovide typical system indications, as discussedbelow and on the next page. Some indicators haveadditional functions, explained later on.

POWER LEDCONDITION

(see note at left)EXPLANATION

ON The system is operating properlyfrom commercial (AC) power; itsbackup battery is in goodcondition.

OFF The system is inoperative due tothe lack of power (from bothcommercial AC and backupbattery); servicing will be required.

FLASHING

(disarmedstate)

Indicates a trouble condition; formore information on displaying andattending to trouble conditions, seepages 29 through 30.

The POWER LED is auseful indicator reflectingthe system's operation.

NOTE: If a troublecondition exists, thePOWER LED will flashonly when the system isin its disarmed state.Once the system isarmed, a previouslyflashing POWER LED willlight steadily.

Page 10: USER MANUAL VER. B

10 User Manual

ARM LED

CONDITION EXPLANATION

ON The system's intrusion detectors arearmed; subsequent violations of aprotected point or area (e.g. a door,a window, unauthorized motion) willresult in a burglar alarm.

OFF The intrusion function of thesystem is disarmed.

The ARM LED indicateswhether or not thesystem's intrusiondetectors are armed.

FLASHING Occurs when using the emergencykeys on the keypad to send panic,fire or special emergency alarm andalso when viewing alarms afterdisarming.

READY LED

CONDITION EXPLANATION

ON All intrusion zones are secure; thesystem is ready to be armed.

OFF One or more intrusion zones are notsecure and the system is not readyto be armed; before the system canbe armed, the condition must beaddressed (see pg. 20 through21).

The READY LEDindicates whether or notthe system's intrusionzones are secured andready to be armed.

FLASHING Indicates that one or more of thesystem's intrusion zones have beenbypassed; for more information onbypassing (see pages 20 through21).

FIRE LED

CONDITION EXPLANATION

ON A fire alarm or fire emergency isin progress or has recentlyoccurred.

OFF All fire zones are operatingnormally.

When lit, the FIRE LEDindicates that the systemis experiencing a firealarm. When flashing, aproblem has beendetected on the firecircuit, and must beserviced.

FLASHING A fault has been detected in thesystem's fire zone and needs to becorrected; for more information onfire zone trouble (see page 29).

Page 11: USER MANUAL VER. B

User Manual 11

ZONE LEDEXPLANATIONCONDITION

SYSTEM DISARMED SYSTEM ARMED

OFF Thecorrespondingzone is secured.

Thecorrespondingzone is secured.

FLASHING The indicatedzone isnot secured.

N/A

The ZONE LEDs indicatethe status of each of thesystem’s intrusion zones.

ON N/A An alarm hasoccurred on theindicated zone.

KEYS The keys on the keypad can be used for a varietyof functions. Each is explained below:

Used to input the numeric codes which may berequired for arming, disarming, triggeringemergency alarms, along with several other specialfunctions.

Used to enter the User Functions mode(see pages 25 through 27).

Used to arm the system's intrusion detectors to the"AWAY" mode (see page 13); it may be necessaryto enter a numeric User Code before pressing theArm key (see pages 13 and 19 for additionalinformation).

Used to arm the system's intrusion detectors to the"STAY" mode (see page 13); it may be necessaryto enter a numeric User Code before pressing theStay key (see pages 13 and 19 for additionalinformation).

Page 12: USER MANUAL VER. B

12 User Manual

Page 13: USER MANUAL VER. B

User Manual 13

Section 3: Things You Should Know About Your ORBIT-6

ArmingYour System

Arming your system enables its intrusiondetectors to trigger an alarm when violated.Remember, fire protection and the protectionoffered by the keypad's emergency keys arealways armed and always available. If your systemis equipped with environmental protection (e.g. gasand/or water level detection) it is always availabletoo.

Secured or Bypassed:Before you arm your system, all of its zones musteither be secured or bypassed. The keypad'sREADY LED, if lit, indicates that all zones aresecured. If the READY LED is not lit, a numberedLED corresponding to the unsecured zone(s) willbe flashing. Before you can arm your system, theindicated zone(s) must be identified and secured. Ifthis is not possible, the affected zone(s) can bebypassed and will be ignored by the system duringthe subsequent armed period. Recall thatbypassing, however necessary, reduces thesystem's degree of intrusion protection.

Page 14: USER MANUAL VER. B

14 User Manual

Full Arming andHome Arming

Your ORBIT-6 offers two kinds of system arming.Full Arming prepares all of the system's intrusiondetectors to sound an alarm, if violated. It is mostoften used when the premises will be empty.Home Arming (or Stay Arming) allows individualsto remain inside and move about the premiseseven after the system is armed. Home Armingarms the perimeter detectors (e.g. door andwindows), while leaving interior detectors (e.g.motion detectors) disarmed (bypassed).

Quick Arming andCode Arming

Your ORBIT-6 also offers two methods of arming.Quick Arming achieves the result with just the

press of a single key (either or ).Code Arming requires that a valid Master Code orUser Code be entered first. Whether or not yoursystem permits Quick Arming was determinedduring its installation.

Entry/Exit Delays Your security system must incorporate anEntry/Exit Delay to allow proper entry and exit toand from the premises without causing inadvertentalarms. A delay period was chosen during yoursystem's installation to provide suitable time toallow for your entry and exit.

Arming with theFront Door Open

If set up by your alarm company, the ORBIT-6allows you the convenience of arming your systemwith the front door either closed or open, afterwhich you must close the door as you leave thepremises before the exit delay period expires. Withsuch a door open (and all other zones secure), thesystem is considered "ready to arm"; the Zone LEDcorresponding to the opened door will be lit, as willyour keypad's READY LED.

Sounder Cutoff It's likely that your security system was installedwith a sounding device (e.g. a siren or a bell).Typically, all sounding devices have cutoffs; that is,they will shut off after a predetermined interval(usually several minutes) set by your alarmcompany. In many locales, this is required by law.Once a sounder shuts off, it is still capable ofresponding to a subsequent alarm during the samearmed period.

Panic Button A special panic button can be installed at anypreferred location, to allow immediate and flexiblealarm notification in time of distress.

Page 15: USER MANUAL VER. B

User Manual 15

The "Squawk"Feature

A feature known as Bell Squawk is available foryour system. If selected by your alarm company,the Bell Squawk causes the system's externalsounder (either a siren or a bell) to produce amomentary "beep" as follows:

One beep: At the conclusion of the Exit Delay,confirming that the system has been successfullyarmed.

Two beeps: Confirming that the system has beendisarmed .

Four beeps: Confirming that the system has beendisarmed after an alarm has occurred.

Follow-Me Feature In case of an alarm event a phone call can bemade to a predefined phone number. There arethree different tone types that represent burglary,fire and special emergency alarms. The Follow-Mefunction can support two phone numbers.

Voice Feature An optional Voice Module can be added to yoursystem. Up to 3 short messages can be recorded.These messages replace the alarm tones normallyproduced in the follow-me mode.

Zone Bypassing It may be convenient to have one (or more) of thezones in your installation bypassed–and thusignored by your system.

Duress Disarming If you are ever coerced into disarming your system,you can comply with the intruder's wishes whilesending a silent, duress alarm, to the CentralStation. To do so, you must use a specialDuress Code. Which when used, will disarm thesystem in the regular manner, while simultaneouslytransmitting a silent alarm to the central station.

Quick Bypassingand

Code Bypassing

Your Orbit-6 offers two methods of Bypassing:Quick Bypassing achieves the result by pressingthe key number corresponding to the zone to bebypassed for 2 seconds.Code Bypassing requires a valid Master Code orUser Code to be entered first.Whether or not your system permits QuickBypassing was determined during its installation.

Page 16: USER MANUAL VER. B

16 User Manual

Section 4: Operating Your SystemIn this section, you'll learn how to perform most of the functions needed toproperly operate your ORBIT-6 and to get the most out of your securitysystem.

EMERGENCY KEYSYour keypad provides three sets of keys, which can be pushed at any time thepolice, fire department, or special emergency is required.

Panic Key Pressing and simultaneously, andfor at least two seconds, will activate aPanic Key alarm.

Fire Emergency Pressing and simultaneously, andfor at least two seconds, will activate aFire Emergency alarm.

SpecialEmergency

Pressing and simultaneously, andfor at least two seconds, will activate a SpecialEmergency alarm.

The annunciation that results during these emergency alarms, along with othersystem sounds, is covered in Section 5.

USER CODES To perform many of the ORBIT-6's functions, afour-digit security code (often called a UserCode) must be entered at the keypad. Inresidential systems, it's likely that all familymembers will share the same User Code. Incertain commercial systems, however, it'scommon to give each authorized employeehis/her own User Code (discussed on page 17).Your ORBIT-6 permits up to ten User Codes.One of the codes is considered the MasterCode; the individual(s) using the Master Codeis given the following special privileges:

•• adding, modifying, and deleting User Codes•• setting the system's internal clock•• performing certain system functions and tests

Except for these considerations, theMaster Code and any User Codes assigned tothe system operate identically.Your ORBIT-6 was given a Master Code of1–2–3–4 during manufacturing. Unless youralarm company has already changed it to suityour preference, it's best to modify this code toone which is unique and personalized. Tochange the Master Code, and/or to set up UserCodes, follow the steps on page 17.

Page 17: USER MANUAL VER. B

User Manual 17

SETTING/CHANGING THE MASTER/USER CODES

STEP DESCRIPTION

1 The system must be disarmed (the ARMED LED will be

OFF). Enter the User Functions Mode ( ) and selectCodes (5):

2 Enter the current 4-digit Master Code:

3 To change the Master Code, press "0":

To enter/change the User Code 1, press "1":

To enter/change the User Code 2, press "2":

To enter/change the User Code 3, press "3":

It is possible to enter/change up to 9 User Codes.

4 Enter the new 4-digit code selected for the Master Code orfor the User Code of your choice:

5 If successful, the keypad will emit a one-second confirmingtone. The selected User Code is now in effect.

Example:To change the Master Code 1234 to a new code 7890, press thefollowing keys: [Q][5] [1] [2] [3] [4] [0] [7] [8] [9] [0] 14243 14243 1442443 Master Code Code I.D. New Code to be changed

Page 18: USER MANUAL VER. B

18 User Manual

DELETING USER CODESAt times, it may be desirable to completely delete a User Code. Note that it isimpossible to delete the Master Code (although it can be changed).

STEP DESCRIPTION

1 The system must be disarmed. Enter the

User Functions Mode ( ) and choose Codes (5):

2 Enter the current 4-digit Master Code:

3 To delete the User Code 1, press "1":

To delete the User Code 2, press "2":

To delete the User Code 3, press "3":

4 Enter 0-0-0-0 (which is NOT a valid code) to clear theselected User Code.

5 If successful, the keypad will emit a one-secondconfirming tone. The selected User Code is now deleted.

Page 19: USER MANUAL VER. B

User Manual 19

ARMING YOUR SYSTEM

STEP DESCRIPTION1 Check the READY LED on your keypad. If lit or flashing,

the system is READY.

If NOT lit or flashing, the system is NOT ready to be armed.Secure or bypass the violated zone(s) and then proceed.

AwayArming

2

Arming when Leaving the Premises Empty:

Enter the four digits of your User Code and press .

NOTE: If you make a mistake when entering your UserCode, the keypad will produce three short beeps. If so, re-enter the above sequence correctly.

If your system has Quick Arming, simply press

3 Leave the premises and close the door. The keypad will beep as counts down the Exit Delay period.

StayArming

2

Arming with the Premises Occupied

Enter the four digits of your User Code and press .

NOTE: If you make a mistake when entering your UserCode, the keypad will produce three short beeps. If so, re-enter the above sequence correctly.

If your system has Quick Arming, simply press .

3 If required, leave the premises and close the door. Thekeypad will beep as it counts down the Exit Delay period.The internal zones will be automatically bypassed.

Note: By pressing (twice) the system will silence the beeps onthe keypad and cancel the entry delay time.

By pressing during exit time will silence the beeps on thekeypad.

Page 20: USER MANUAL VER. B

20 User Manual

BYPASSING A ZONE

STEP DESCRIPTION1 Check the READY LED on your

keypad. If NOT lit or flashing, thesystem has at least one faulted intrusionzone identified by noting which LED(s)are flashing in the keypad's ZONESarea, shown at the left.

CodeBypassing

2

To bypass such a zone(s) and cause it to be ignored by thesystem, enter the following sequence correctly:

NOTE: If you make a mistake when entering your UserCode, the keypad will produce three short beeps. Re-enterif necessary.An additional zone(s) can be bypassed at the same time byadding its number to the sequence. For example, to bypassZones 2 and 3, press:[ ] + [ 1 ] + [USER CODE] + [ 2 ] + [ 3 ]The same sequence can “toggle” the bypass(es) during thedisarmed period so that they may be either applied orremoved.

Press # or Q to approve or wait 2 seconds (timeout period).

Page 21: USER MANUAL VER. B

User Manual 21

BYPASSING A ZONE (CONT.)

If the system is programmed for quick bypass the followingoption is available:

QuickBypass

2

To bypass a zone simply press the corresponding keypadnumber for at least 2 seconds.

An additional zone(s) can be bypassed at the same time byadding its number to the sequence. For example, to bypassZones 2 and 3, press:

[ 2 ] for 2 seconds + [ 3 ]

The same sequence can “toggle” the bypass(es) during thedisarmed period so that they may be either applied orremoved.

3 The READY LED, when flashing, indicates that there is oneor more bypassed zones. Any zone(s) bypassed during thedisarmed period will remain bypased when the system isarmed.

Zone(s) that are bypassed, during the time the system isarmed, will automatically be restored to its normal,unbypassed condition, when the system is disarmed.

DETERMINING WHICH ZONE(S) IS BYPASSED

STEP DESCRIPTION1 The system must be

disarmed. If the keypad’sREADY LED is flashing,there is at least onebypassed zone, in thesystem. To determinewhich zone is bypassed,follow this sequence:

If quick bypass is enabled in yoursystem, simply press:

2 Observe the keypad’s ZONES area. LED(s) corresponding to thebypassed zone(s) will light for several seconds.

Page 22: USER MANUAL VER. B

22 User Manual

DISARMING AN ARMED SYSTEM AND/OR SILENCING AN ALARMIN PROGRESS

STEP DESCRIPTION

1 If outside the premises, open an "entry" door; the keypad(s) willbeep indicating that the Entry Delay period has begun.

2 Disarming an armed systemBefore the Entry Delay expires, enter the four digits of your User Code.

NOTE: If you make a mistake when entering your User Code,the keypad will produce three short beeps. If so, re-enter theabove sequence correctly.

2 Silencing an alarm in progressObserve the keypad. If any of the following conditions is evident,an alarm has occurred:

·• the ARM LED is flashing

·• a Zone LED is lit steadily

·• the FIRE LED is lit steadilyDisarm the system by entering your User Code:

It's best to enter the premises only after police or a securitycompany has investigated and you feel confident that the burglaris no longer on your premises.

3 IMPORTANT!If the alarm was caused by a tripped Smoke Detector(s), thekeypad's FIRE LED will remain lit—providing an indication thatthe fire system must be reset before it will be capable ofdetecting subsequent alarms. Furthermore, until reset, you willbe prevented from arming your system. To reset the fire system and to turn off the FIRE LED, refer toActivate a Utility Output/Reset Smoke Detectors, in the table onpage 25.

Page 23: USER MANUAL VER. B

User Manual 23

DURESS DISARMINGAll 10 user codes can activate the Duressdisarming by adding 1 to the last digit of youruser code.

Example:

if your code is 1-2-3-4 your duress code is 1-2-3-5

If your user code is 5-6-7-0 your duress code is5-6-7-1

Note: Under no circumstances must the DuressCode be used haphazardly or without reason.Central Stations, along with PoliceDepartments, treat Duress Codes veryseriously and take immediate action.

DISARMING BY USING THE DURESS CODE

STEP DESCRIPTION

1 If outside the premises, open an "entry" door. The keypad(s) willbeep indicating that the Entry Delay period has begun.

2 Enter your 4-digit Duress Code:

Once entered, it will disarm your system and send a silent

alarm to the Central Station.

A utility output in your system may be programmed to be activatedcontinuously after an entry of the duress code.If so, deactivation must be done manually by one of the followingprocedures:1. Arming the system.2. Disarming the system after an alarm that occurred while the utility

output was still activated.

Page 24: USER MANUAL VER. B

24 User Manual

Section 5: System Sounds

Besides the visual indications provided by your keypad(s), your system isdesigned to produce audible annunciation after certain events. Depending onthe circumstance, such sounds may be made by your system's keypad(s), itsexternal sounder (e.g. a siren or bell),

EVENT KEYPAD SOUND SIREN/BELL

IntrusionAlarm

MAYBE

(see Note 5)

YES

(continuous)

Fire AlarmRapidly repeatingtones (see Note 3)

YES

(staggered)

KeypadPoliceEmergency

A momentary chirpOPTIONAL

(see Note 2)

Keypad FireEmergency

Rapidly repeatingtones (see Note 3)

YES

KeypadSpecialEmergency

A momentary chirp no sound

Arming ordisarming

A one second tone ifcompleted correctly;three rapid error beepsif incorrect (see Note 3)

no sound

Entering anincorrect keysequence

Three rapid beeps

(see Note 3)no sound

Entry Delaycountdown

Slowly repeating tonesuntil the entry delayperiod expires (see Note3)

no sound

Exit Delaycountdown

Slowly repeating tonesuntil the exit delayperiod expires (see Note3)

OPTIONAL

(see Note 1)

NOTE 1:If selected during the installation,a brief "chirp" may be heard fromthe siren when the Exit Delayperiod expires. See page 14 foradditional information.

NOTE 2:Whether or not the PoliceEmergency alarm is annunciatedby the external sounder isdetermined by the alarmcompany during your system'sinstallation.

NOTE 3:Keypad beeps in response toEntry/Exit Delay countdowns,Keypad Fire Emergencies, andkeypad errors and confirmationsare typically enabled. At theuser's discretion, such beepsmay be disabled. See page 14for additional information.

NOTE 4:Any intrusion zone, if selected forthe chime feature, will, whenviolated during the disarmedperiod, cause the keypad toannunciate the event (seepage 8). Through User Functions(see page 27), the chime canalso be disabled when notdesired.

NOTE 5:Based on decisions made at thetime your alarm system wasinstalled, keypad(s) may beepduring this type of alarm.

Entering datainto the UserFunctionsmode

(see page 25)

A one second tone ifcompleted correctly;three rapid error beepsif incorrect (see Note 3)

no sound

Page 25: USER MANUAL VER. B

User Manual 25

0

Section 6: User FunctionsYour ORBIT-6 comes with a variety of selectable User Functions. By enteringthe User Functions mode, a number of options become available whichdetermine how your alarm system operates, such as:• adding, modifying, and deleting User Codes• bypassing zones• displaying a "memory" of previous alarms• displaying system troubles• disabling (and re-enabling) keypad sounds• setting the system's internal clock, time and date•• performing certain system testsAmong these User Functions are some which have already been covered. Asrequired, each will be explained below.

USERFUNCTION DESCRIPTION PRESS COMMENTS

ZoneBypassing

+

+ USER CODE +

(zone number to bebypassed or unbypassed)

QuickBypassing

+

+(zone number to be

bypassed or unbypassed)

Extra QuickBypassing

To bypass orunbypass aselected zone(s)

for at least 2 sec.

(zone number to bebypassed or unbypassed)

Refer toZone Bypassingprocedures, alreadydiscussed onpage 20.

Activate aUtility Output

To activate or de-activate a UtilityOutput

+

+ USER CODE +

(Utility Output numberto be activated or

deactivated)

Refer toUtility Outputson page 8; alsoconsult your securitydealer.

Reset aSmokeDetector(s)

To reset a SmokeDetector

+ + USER CODE

+(Utility Output number

responsible for resettingthe Smoke Detector(s)

Refer toSystem Troubleson page 29; alsoconsult your securitydealer.

Page 26: USER MANUAL VER. B

26 User Manual

USERFUNCTION DESCRIPTION PRESS COMMENTS

DisplaySystemTroubles

Display systemproblem(s) causingthe POWER LEDto flash

+

Refer toSystem Troubles onpage 29.

DisplayAlarmMemory

Reviews anyalarms occurringduring the lastarmed period

+

Via its LEDs, thekeypad reveals thezone(s) in which analarm occurred duringthe previously-armedperiod.After several seconds,the LEDs will restoreto normal.

Add, Modify,Delete Userand MasterCode(s)

+

+ MASTER CODE +(number of the Code tobe added, modified, ordeleted)+

(the new 4-digit code)

NOTE: Use 0-0-0-0 todelete the Code.

Refer to Setting /Changing Master /User Codes,discussed on page 17.

Setting theDate

Set the systemsdate

++ MASTER CODE+ ++

To enter date as: MMDD YYMM: month 1-12DD: Day 1-31Year: 00-99

Setting theTime

Sets the system’sinternal clock

+

+ MASTER CODE

+enter time in HH:MMformat

Use 24-Hour format,as in these examples:• for 12:30 AM,

enter 0030• for 8:45 AM,

enter 0845• for 6:15 PM,

enter 1815the clock must be setto insure propersystem operation.

Setting theAuto Arm

+

+ MASTER CODE

+enter time in HH:MMformat

Use 24-Hour format.

DYY

D

Page 27: USER MANUAL VER. B

User Manual 27

USERFUNCTION DESCRIPTION PRESS COMMENTS

Set Follow-Me PhoneNumber 1- 4

Sets the first phonenumber for thefollow-me function(up to 24 digits)

+or +or +or ++ MASTER CODE+ Phone Number+ [#]

Enter the phonenumber in the samemanner as MS numberduring installation.

* If required, includethe following specialfunctions to achievethe effect listed in thetable:

FUNCTION SEQUENCE RESULTSstop dialing and wait for a new dial tone [STAY], [1] Await a fixed period before continuing [STAY], [2] Bswitch from Pulse to Tone (or from Tone to Pulse) [STAY], [3] C

send the DTMF Q character [STAY], [*] *send the DTMF # character [STAY], [#] #

Page 28: USER MANUAL VER. B

28 User Manual

USERFUNCTION DESCRIPTION PRESS COMMENTS

KeypadSounder/ChimeOperation/AudibleKiss-OffIndication

Determines how thekeypad's internalsounder will operateunder specificconditions

+

+ MASTER CODE

+ / OR

+ / OR

After entering theMaster Code,press toenable/disable currentoperation of keypad'sbeeps (see Note 3 onpage 24) .

Press todisable/enable the"chime" for intrusionzones having thisfeature (see page 8).

Press todisable/enable theAudible Kiss-OffIndication.

EventLogger

Retrieves eventslocated in the eventlogger memory (upto 99 events).

+ + MASTER CODE + Event Number

The event number isrepresented by thezone LEDs (events arepresented from thelast entered to the firstregistered).

SystemTesting

Provides a brief testof the following:·• keypad LEDs·• keypad sounder·• external siren·• standby battery

+

+ MASTER CODE

The external sounderwill be activatedmomentarily.• The keypad's LEDswill flash.• If enabled, thekeypad's sounder willbeep.• A low battery (seepages 8 and 29) or aloss of commercialpower will cause thePOWER LED to flash;if so, consult yoursecurity dealer.

Page 29: USER MANUAL VER. B

User Manual 29

Section 7: System TroublesYour ORBIT-6 is designed to report any troubles or malfunctions it may detect.Notification that a problem exists is made to the user, through indications onthe keypad(s) and, in many cases, to the Central Station and to your dealer.Any incidence of trouble should be taken seriously and acted uponimmediately. If not remedied quickly, a trouble condition will likely compromiseyour system and prevent it from properly doing its job.

The ORBIT-6 is designed to be as trouble-free as possible. Were a problem todevelop, the POWER LED will flash about once every second. If so, todetermine the problem, perform the sequence on the following page.

In certain cases, the keypad's FIRE LED may remain lit steadily, even thoughthere is no alarm in progress and the system is disarmed. Refer to theexplanation and remedy below:

USER FUNCTION DESCRIPTION AND REMEDY

the FIRE LEDremains lit

After a fire alarm has occurred and been silenced, thekeypad's red FIRE LED will remain lit steadily if a SmokeDetector (presumably the one which caused the alarm)remains tripped. Until reset, a tripped Smoke Detector willprevent the READY LED from being lit, and will NOT permitthe system to be armed.

To reset a tripped Smoke detector and to extinguish the redFIRE LED, follow this procedure, which is typical:

++ USER CODE

+ 64444744448

UTILITY OUTPUT NUMBER(which is responsible for resetting the Smoke Detector)

Consult your security dealer for alternate information onresetting smoke detectors, if applicable.

Once done, the READY LED will indicate the system'sstatus and you will be able to arm your system.

Page 30: USER MANUAL VER. B

30 User Manual

IDENTIFYING SYSTEM TROUBLES

STEP DESCRIPTION

1 Perform if the POWER LED is flashing. If lit steadily, there are no system troubles. To view trouble conditions, the system must be disarmed. Enter the User Functions Mode by pressing [ ] and then select View Troubles (3):

2 The keypad will beep and its LEDs will light, reflecting theinformation below. After several seconds, the display willreturn to normal.

FLASHING: Trouble Detected

OFF: (normal in this mode)

OFF: (normal in this mode)

IF ON: Fire Zone Trouble(contact your dealer)

IF ON: Low Battery (contact dealer)

IF ON: AC Power Loss (see Note 1)

IF ON: Clock, Time & Date Not Set(see page 19)

IF ON: Communications Trouble(see Note 2)

3

IF ON: Bell Loop Trouble(see Note 3)

In an 8 zone keypad there are 2 more LEDs which are only zone indicatorsand not system indicators.NOTE 1: Check that the ORBIT-6's Plug-In Transformer has not beenremoved from its outlet. If intact, check that a blown fuse, a switch, or atripped circuit breaker has not interrupted the circuit supplying power tothe transformer.NOTE 2: The ORBIT-6 has failed in its attempts to report an alarm ortrouble condition to the Central Station. Check that your telephone line isfunctioning. Check to see if your external bell has been tampered with. If theproblem still exists contact your dealer.NOTE 3: The ORBIT-6 has failed in its attempt to identify the Bell Loop.

It is possible for more than one trouble to be present at the same time.If so, multiple Zone LEDs will be lit simultaneously.

Page 31: USER MANUAL VER. B

User Manual 31

EMERGENCY EVACUATION PLANS

An emergency evacuation plan should be established and used during anactual fire alarm condition. The following steps are recommended by theNational Fire Protection Association (NFPA) and can be used as a guidewhen establishing a similar plan for your circumstances.

1. Draw a floor plan of your premises showing windows, doors, stairs,and rooftops, which can be used for escape. An example has beenprovided below.

2. Indicate each occupant's escape routes by determining two means offlight from each room. One should be the normal exit from thebuilding, while the other may be a window that opens easily, oranother alternate route. An escape ladder may have to be locatednear an escape window if there is a long drop to the ground below.Always keep escape routes free from obstruction.

3. Practice escape procedures and set a meeting place outdoors for aheadcount of the building's occupants.

4. In a home, sleep with the bedroom door closed to increase yourescape time. If a fire is suspected, first test the door for heat. If youthink it is safe, brace your shoulder against the door and open itcautiously. Be ready to slam the door if smoke and heat rush in.

5. After escaping from a fire, call the Fire Department from a neighbor'sphone.

After the installation of yourSecurity System has been completed,notify your local Fire and PoliceDepartments to give them your nameand address for their records. Earlywarning fire detection is bestachieved by the installation of firedetection devices in all rooms. Thisequipment should be installed inaccordance with the National FireProtection Association's Standard 72.

For additional information, write to theNational Fire Protection Association(NFPA) at Batterymarch Park,Quincy, MA 02289.