12
39" 48" 18" Top View Front View Side View (Both Sides Typ.) Bottom View UPS Cabinet (Standard) (4) 0.69" Dia. Typ. Floor Mounting Holes 29.25" 48" 1.5" 5" 5" 34.75" 15" 9" 1.5" 34.5" 39" 32" 1.25" 18" (2) 1.5" or 2" Conduit knockouts (2) .75" or 1" Conduit knockouts (2) 1.5" or 2" 1” Air Exhaust Clearance 1” Air Exhaust Clearance Conduit knockouts (2) .75" or 1" Conduit knockouts 39" Drawn by: Chun Chi 7/15/09 Date: Date: Date: Chkd.: Appvd.: 6001-033-14 Rev C1 1 Phase UPS 3 KW UPS & Battery Cabinet Installations

UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",

Embed Size (px)

Citation preview

Page 1: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",

39"

48"

18"

Top View

Front View Side View(Both Sides Typ.)

Bottom View

UPS Cabinet (Standard)

(4) 0.69" Dia. Typ.Floor Mounting Holes

29.25"

48"1.5"

5"

5"

34.75"

15"

9"

1.5"34.5"

39"

32"

1.25"

18"

(2) 1.5" or 2"Conduitknockouts

(2) .75" or 1"Conduitknockouts

(2) 1.5" or 2"

1” Air ExhaustClearance

1” Air ExhaustClearance

Conduitknockouts

(2) .75" or 1"Conduitknockouts

39"

Drawn by:

Chun Chi 7/15/09

Date:

Date:

Date:

Chkd.:

Appvd.:

6001-033-14 Rev C1

1 Phase UPS 3 KW

UPS & Battery Cabinet

Installations

Page 2: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",

Top View

Front View

Bottom View(4) 0.68" Dia. Typ.Floor Mounting Holes

68"

2.25"

34.8"

15"

1.5"34.5"

39"

32"(2) .75" or 1"Conduitknockouts

(2) 1.5" or 2"Conduitknockouts

Side View(Both Sides Typ.)

46"

1.5"

5"9"

1.25"

18"

(2) 1.5" or 2"Conduitknockouts

1” Air ExhaustClearance

1” Air ExhaustClearance

(2) .75" or 1"Conduitknockouts

39"

39"

48"

18"

UPS Cabinet (Standard)Battery Cabinet

39"

68"

18"

BatteryCB

1. Matching Battery Cabinet has same physical dimensions.2. Each battery cabinet includes 1 CB. 3. Each battery cabinet have top and sides conduit entry and same floor mounting hole dimensions.4. Optional Seismic Brackets (P/N: 9100-1317-02) are available. When seismic bracket used, 8" min. space required between cabinets. Anchoring hardware to be supply by customer.

NOTE:

Drawn by:

Chun Chi 7/15/09

Date:

Date:

Date:

Chkd.:

Appvd.:

6001-033-01 Rev C1

1 Phase UPS 5 KW

UPS & Battery Cabinet

Installations

Page 3: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",

DESCRIPTIONREV

REVISION

APPROVEDDATE

TITLE

SCALE: OFSHT

SIZE

AREVDWG

CHKD:

CADD:

APPVD:

UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE IN INCHES.

± 1/64FRACTIONS

TOLERANCES ARE:DECIMALS.XX ± .03.XXX ± .010

EST. WT:

ANGLES± 1/2∞

ECO

CRUCIAL POWER PROPRIETARYCONFIDENTIAL INFORMATION

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

LEFT VIEW

BOTTOM VIEW

FRONT VIEW

NOTES: (UNLESS OTHERWISE SPECIFIED)

1) DIMENSIONS SHOWN ARE APPROXIMATE.

2) CONSTRUCTION: INDOOR NEMA 1.

5) PROVISION FOR SEISMIC BRACKET

3) RATING & WEIGHT: CHARTED.

4) WEIGHT ARE APPROX. DEPENDING

ON OPTION(S).

RIGHT VIEW

TOP VIEW

STD VRLA

Using 51” wide cabinet

BATTERY

2300 LBS

3050 LBS

3370 LBS

4120 LBS

4200 LBS

WT. (NOTE 4)

7.5

KW

15

10

12.5

17

X1 6/21/10 H. BAIKPRELIMINARY

KNOCK OUTFOR 1", 1.5" & 2"CONDUIT (TYP)

49 (

BO

TH

SID

ES

)

COMMENTS:

APPROVED WITH COMMENTS

APPROVED

NAME: SIGNATURE:

DISAPPROVED DATE:

6001-155 C1NONE 1 1

HAI NGUYEN 6/21/10

HAI NGUYEN 6/21/10

H. BAIK 6/21/10

7.5 KW - 17 KW, 1 PHASEINVERTER WITH 90 MIN. BATT.

1

70

NOTE 5

MGT HOLES

25

44.75

25.5

1 AIR INTAKECLEARANCEREQUIRED

30.5

AIR EXHAUST

1 AIR INTAKECLEARANCEREQUIRED

9.5

51

546

3.53.5

Page 4: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",
Page 5: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",

1. Service Clearance Areas are shaded. 2. Each battery cabinet includes 1 C/B.3. Each battery cabinet have top and both sides conduit entry and same floor mounting hole dimensions as UPS cabinet. (See doc #: 6001-032-03 for detail).4. Optional Seismic Brackets (P/N: 9100-1317-02) are available. When seismic bracket used, 8" min. space required between cabinets. Anchoring hardware to be supply by the customer.5. Optional racks (P/N: 9100-1429-XX) available for stack battery cabinets. (see doc #: 6001-032-07).6. Consult factory for different back-up times and number of battery cabinet require.

1"

Battery Cabinet 1UPS Cabinet

39"39" 12"12"

18"

18"

NOTE:

39"

48"

18"

Drawn by:

Chun Chi 2/1/06

Date:

Date:

Date:

Chkd.:

Appvd.:

6001-033-02 Rev C1

1 Phase UPS with 90 Min

Battery Backup

Battery Cabinet Installations

Layout Configuration 1

7.0 kW, 7.5 kW, 8.8 kW, 10 kW, 10.5 kW, 12.5 kW, 14 kW, 15 kW, and 17 kW

Layout Configuration 2

Layout Configuration 3

36" 18"18"

BatteryCabinet

1

39"

UPSCabinet

56"

54"

28.25"26.25"

4"

.56 Dia. (typ.)

4"

CabinetBottomView

2.1 kW and 3 kW

UPS & Battery Cabinet arein a Single Cabinet.

UPS & Battery Cabinet arein a Single Cabinet.

UPSCabinet

BatteryCabinet1

51"W x 30.25"DService Clearance

Optional Racks (P/N: 9100-1429-XX)

28.25"

12"

123.5"

49"

66.25"

142"

56"

39"

68"

18"

3.5 kW, 5.0 kW, and 5.25 kW

Page 6: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",

DESCRIPTIONREV

REVISION

APPROVEDDATE

TITLE

SCALE: OFSHT

SIZE

AREVDWG

CHKD:

CADD:

APPVD:

UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE IN INCHES.

± 1/64FRACTIONS

TOLERANCES ARE:DECIMALS.XX ± .03.XXX ± .010

EST. WT:

ANGLES± 1/2∞

ECO

CRUCIAL POWER PROPRIETARYCONFIDENTIAL INFORMATION

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

C1 6/22/10 H. BAIKPRELIMINARY

NOTES: (UNLESS OTHERWISE SPECIFIED)

2) CONSTRUCTION: INDOOR NEMA 1.

1) ALL DIMENSIONS SHOWN ARE APPROXIMATE.

BOTTOM VIEW

TOP VIEW

FRONT VIEWLEFT VIEW RIGHT VIEW

BATTERYLONG LIFE

31.87" TYP

34.37" TYP

1.5"

TY

P

5" T

YP

1.5" / 2"CONDUIT

46"

3.25

"

11"

4.5"

8" 18"

68"

34.75"

3/4" / 1"CONDUIT

39"

1" CLEARANCE 2" CLEARANCE

14"

MTG HOLES

6001-152 C11 1

HAI NGUYEN 6/22/10

HAI NGUYEN 6/22/10

H. BAIK 6/22/10

3KW - 5KW, 1 PHASEINVERTER WITH 90 MIN. BATT.

Page 7: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",

DESCRIPTIONREV

REVISION

APPROVEDDATE

TITLE

SCALE: OFSHT

SIZE

AREVDWG

CHKD:

CADD:

APPVD:

UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE IN INCHES.

± 1/64FRACTIONS

TOLERANCES ARE:DECIMALS.XX ± .03.XXX ± .010

EST. WT:

ANGLES± 1/2∞

ECO

CRUCIAL POWER PROPRIETARYCONFIDENTIAL INFORMATION

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

2520 LBS

3226 LBS

3722 LBS

4560 LBS

4640 LBS

WT. (NOTE 4)

7.5

KW

15

10

12.5

17

LEFT VIEW

BOTTOM VIEW

FRONT VIEW

NOTES: (UNLESS OTHERWISE SPECIFIED)

1) DIMENSIONS SHOWN ARE APPROXIMATE.

2) CONSTRUCTION: INDOOR NEMA 1.

5) PROVISION FOR SEISMIC BRACKET

3) RATING & WEIGHT: CHARTED.

4) WEIGHT ARE APPROX. DEPENDING

ON OPTION(S).

RIGHT VIEW

TOP VIEW

LONG LIFEBATTERY

C1 6/21/10 H. BAIKPRELIMINARY

KNOCK OUTFOR 1", 1.5" & 2"CONDUIT (TYP)

49 (

BO

TH

SID

ES

)

COMMENTS:

APPROVED WITH COMMENTS

APPROVED

NAME: SIGNATURE:

DISAPPROVED DATE:

6001-150 C1NONE 1 1

HAI NGUYEN 6/21/10

HAI NGUYEN 6/21/10

H. BAIK 6/21/10

7.5 KW - 17 KW, 1 PHASEINVERTER WITH 90 MIN. BATT.

70

NOTE 5

MGT HOLES

25

44.75

25.5

1 AIR INTAKECLEARANCEREQUIRED

30.5

AIR EXHAUST

1 AIR INTAKECLEARANCEREQUIRED

9.5

51

546

3.53.5

AIR INTAKE

1

Using 51” wide cabinet

Page 8: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",

C1

CRU

CIA

L PO

WER

PR

OPR

IETA

RYC

ON

FID

ENTI

AL

INFO

RMAT

ION

Page 9: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",
Page 10: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",

Remote Status Panel displays the following:NPUT OK: Input power is within acceptable range

INVERTER ON: Inverter is on.

ON BYPASS: Unit is on bypass mode.

ON BATT: Unit is running from Battery.

LOW BATT: Battery voltage is at low voltage before shutdown.

SUM ALARM: Unit is on critical alarm such as: Over temperature, DC OV/UV.

.noitidnoc mrala rof gninraw elbiduA :NROH

SILENCE SWITCH: Silences the audible warning.

LED TEST: Tests the LED’s by push in.

DISPLAY PANEL

TO UPS P100 TERMINAL BLOCKKSEE INSTALLATOIN

INSTRUCTION SHIPPEDWITH THE ASSEMBL

Y

USEBUMPERSFORCONSOLINSTALL

BACK MOUNITNGPROVISION

SIDEMOUNT

PROVSION

REMOTE STATUS PANEL ASSEMBLY: 9100-1020-06: SINGLE PHASE 9100-1020-07: THREE PHASE

Page 11: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",
Page 12: UPS Cabinet (Standard) - Crucialpower.com · UPS Cabinet (Standard) Battery Cabinet 39" 68" 18" Battery CB ... INDOOR NEMA 1. 5) ... X1 PRELIMINARY 6/21/10 H. BAIK KNOCK OUT FOR 1",