Head Office 62 Parkhurst Drive Knoxfield VIC 3180 T: 03 9887 2131 New South Wales Unit 1, 20-22 Foundry Road Seven Hills NSW 2147 T: 02 9838 0000 Queensland Unit 1, 8 Reichert Street Molendinar QLD 4214 T: 07 5679 6821 [email protected] sunloverheating.com.au Commercial Heat Pump Specifications Commercial Series Specifications – Heating & Cooling Model Oasis C95 Oasis C120 Oasis C145 Oasis C200 Performance Condition: Air 27°C / Water 26°C Heating Capacity kW 113 141 167 217 Running Current A 31.4 38 50 79 Performance Condition: Air 19°C / Water 26°C Heating Capacity kW 95 120 145 190 Heating Power Input kW 17.5 21.8 25.4 32 Cooling Capacity kW 64 80 97 119 Cooling Power Input kW 18 25.8 28 39.1 Running Current A 31.4 38 50 79 Power Supply V/Ph/Hz 400V/3/50 400V/3/50 400V/3/50 400V/3/50 Compressor Quantity 4 2 2 4 Compressor Scroll Scroll Scroll Scroll Fan Quantity 3 2 2 2 Fan Amps A 0.72 0.9 0.9 0.9 Fan Direction Vertical Vertical Vertical Vertical Noise dB(A) 61 62 71 73 Water Connection mm 63 110 110 110 Water Flow Volume l/m 467 585 700 830 Water Pressure Drop (max) kPa 16 16 16 18 Unit Shipping Dimensions (L/W/H) mm 2175 x 1070 x 2030 2175 x 1070 x 2030 2175 x 1070 x 2030 2180 x 1070 x 2060 Net / Shipping Weight kg 668 / 608 678 / 708 678 / 708 960 / 990 Cooling capacity is based on 19 °C ambient air temperature and 26°C water temperature

UPDATED heat Pump Specs 07.07 - Sunlover Heating · Title: Microsoft Word - UPDATED heat Pump Specs 07.07.17 Author: ACasten Created Date: 6/5/2018 2:53:10 PM

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: UPDATED heat Pump Specs 07.07 - Sunlover Heating · Title: Microsoft Word - UPDATED heat Pump Specs 07.07.17 Author: ACasten Created Date: 6/5/2018 2:53:10 PM

Head Office 62 Parkhurst Drive Knoxfield VIC 3180 T: 03 9887 2131

New South Wales Unit 1, 20-22 Foundry Road Seven Hills NSW 2147 T: 02 9838 0000

Queensland Unit 1, 8 Reichert Street Molendinar QLD 4214 T: 07 5679 6821

[email protected] sunloverheating.com.au

Commercial Heat Pump Specifications

Commercial Series Specifications – Heating & Cooling

Model Oasis C95

Oasis C120

Oasis C145

Oasis C200

Performance Condition: Air 27°C / Water 26°C Heating Capacity kW 113 141 167 217

Running Current A 31.4 38 50 79

Performance Condition: Air 19°C / Water 26°C Heating Capacity kW 95 120 145 190

Heating Power Input kW 17.5 21.8 25.4 32

Cooling Capacity kW 64 80 97 119

Cooling Power Input kW 18 25.8 28 39.1

Running Current A 31.4 38 50 79

Power Supply V/Ph/Hz 400V/3/50 400V/3/50 400V/3/50 400V/3/50

Compressor Quantity 4 2 2 4

Compressor Scroll Scroll Scroll Scroll

Fan Quantity 3 2 2 2

Fan Amps A 0.72 0.9 0.9 0.9

Fan Direction Vertical Vertical Vertical Vertical

Noise dB(A) 61 62 71 73

Water Connection mm 63 110 110 110

Water Flow Volume l/m 467 585 700 830

Water Pressure Drop (max) kPa 16 16 16 18

Unit Shipping Dimensions (L/W/H)

mm 2175 x 1070 x 2030

2175 x 1070 x 2030

2175 x 1070 x 2030

2180 x 1070 x 2060

Net / Shipping Weight kg 668 / 608 678 / 708 678 / 708 960 / 990

Cooling capacity is based on 19 °C ambient air temperature and 26°C water temperature

Page 2: UPDATED heat Pump Specs 07.07 - Sunlover Heating · Title: Microsoft Word - UPDATED heat Pump Specs 07.07.17 Author: ACasten Created Date: 6/5/2018 2:53:10 PM

Head Office 62 Parkhurst Drive Knoxfield VIC 3180 T: 03 9887 2131

New South Wales Unit 1, 20-22 Foundry Road Seven Hills NSW 2147 T: 02 9838 0000

Queensland Unit 1, 8 Reichert Street Molendinar QLD 4214 T: 07 5679 6821

[email protected] sunloverheating.com.au

Commercial Heat Pump Specifications

Specifications > Oasis C95

Specifications > Oasis C120

> Oasis C145

Specifications > Oasis C190

Specifications > Oasis C220