54
Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. © Kawneer Company, Inc., 2014 kawneer.com 1 EC 97911-063 AA TM 3350 IsoPort TM Window JULY, 2014 ADME050 INDEX LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m – meter cm – centimeter mm – millimeter s – second Pa – pascal MPa – megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. FIXED WINDOW................................................................................ 3-5 SINGLE HUNG WINDOW ............................................................... 6-10 DOUBLE HUNG WINDOW ........................................................... 11-15 HORIZONTAL SLIDER WINDOW ................................................. 16-20 WIND LOAD CHARTS .................................................................. 21-28 DEADLOAD CHARTS ....................................................................... 29 RECEPTORS, SUB SILLS AND ANCHORING................................. 30 THERMAL CHARTS ..................................................................... 31-53

ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

1

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

INDEX

LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.

Metric (SI) conversion figures are included throughout these details for reference.Numbers in parentheses ( ) are millimeters unless otherwise noted.

The following metric (SI) units are found in these details:

m – meter

cm – centimeter

mm – millimeter

s – second

Pa – pascal

MPa – megapascal

Kawneer reserves the right to change configurations without prior notice when deemed necessaryfor product improvement.

FIXED WINDOW ................................................................................ 3-5

SINGLE HUNG WINDOW ............................................................... 6-10

DOUBLE HUNG WINDOW ........................................................... 11-15

HORIZONTAL SLIDER WINDOW ................................................. 16-20

WIND LOAD CHARTS .................................................................. 21-28

DEADLOAD CHARTS ....................................................................... 29

RECEPTORS, SUB SILLS AND ANCHORING ................................. 30

THERMAL CHARTS ..................................................................... 31-53

Page 2: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

2

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

BLANK PAGE

Page 3: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

3

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

FIXED WINDOW

For specific product applications,Consult your Kawneer representative.

Standard Features

• HighPerformanceCommercialWindow

• IsoPortTM Thermal Break

• ScrewandSplineFrameCornerJoinery

• FactorySiliconeGlazed

• InteriorAppliedGlazingBead

• ArchitecturalAnodizedFinishesandAppliedCoatings

• TwoYearManufacturer'sWarranty

Fixed Window

Exterior Interior

Thermal Break

Page 4: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

4

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

FIXED WINDOW

FIXED WINDOW PRODUCT PERFORMANCE

AirInfiltration NAFS-08

WaterResistance NAFS-08

DesignLoad

NAFS-08

Thermal Transmittance

AAMA 507 NFRC 100

Condensation Resistance* AAMA 1503

Condensation Temperature

Index* CSA A440.2

Sound Transmittance** ASTM E 1425 ASTM E 1332

OPTIONAL CLASS and GRADE

TESTING STANDARD

FRAME DEPTH

TYPICAL WALL THICKNESS

TYPICAL MAX. VENT SIZE

TYPICAL MIN. VENT SIZE

TYPICAL CONFIGURATIONS

STANDARD INFILL OPTIONS

STANDARD HARDWARE

OPTIONAL HARDWARE

OTHER OPTIONS

CLASS AW-PG70-FW

AAMA / WDMA / CSA / 101 / I.S.2 / A440-08 (NAFS-08)

3-1/2" Overall Frame Depth

.070" Nominal

60" x 99"

15" x 15"

1"

Not Applicable

Not Applicable

Between the Glass Muntin GridsExterior Applied Muntin Grids Perimeters and Sills Exterior Pannings and Interior Trims True Intermediate Muntin Structural Mullions Vertically or Horizontally Stacked Strap Anchors Nailing Fin Flange

≤ 0.10 Cfm/ft2 CW - 10 PSF AW - 15 PSF

50 PSF

Note: "U" Values based on computer simulations utilizing Insulating Glass, Low E Coatings and Warm Edge Spacers. See Thermal Charts for various glass types.

* CRF and Temperature index based on high performance Low E Glass and Warm Edge Spacers.

** Acoustical test based on laminated glass.

"U" Factor 0.33 to 0.56

CRF frame - 67 CRF glass - 71

I frame - 60 I glass - 62

STC - 36 OITC - 28

CLASS and GRADE CLASS CW-PG50-FW / AW-PG50-FW

70 PSF

Page 5: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

5

EC 97911-063

4 6

1

3

3/8"

1-13

/16"

3-1/2"

3/8"

1-13

/16"

3-1/

2"

3/8"

1-13/16"

1

3

64

5

2

3-1/

2"

3/8"

1-13/16"

2-1/

2"

2-1/2"

5

2

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

FIXED WINDOW

HEAD

SILL

TYPICAL ELEVATIONLog onto www.kawneer.com for other configurations

SCALE : 3" = 1'-0"

JAMB VERTICAL JAMB

HORIZONTAL

AATM3350 IsoPortTM FIXED WINDOWStandard Design

D.L.O

W.D.

O.D.

D.L.O

W.D.

D.L

.O

W.D

.

O.D

.

D.L

.O

W.D

.

O.D

.

O.D.

D.L.OD.L.O

D.L

.OD

.L.O

Page 6: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

6

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

SINGLE HUNG WINDOW

For specific product applications,Consult your Kawneer representative.

Standard Features

• HighPerformanceCommercialWindow

• IsoPortTM Thermal Break

• ScrewandSplineFrameandSashCornerJoinery

• FactorySiliconeGlazed

• InteriorAppliedGlazingBead

• ArchitecturalAnodizedFinishesandAppliedCoatings

• TwoYearManufacturer'sWarranty

Single Hung Window

Exterior Interior

Thermal Break

Page 7: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

7

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

SINGLE HUNG WINDOW

OPTIONAL CLASS and GRADE CLASS AW-PG70-H (MAX. SIZE 52" X 99")

TEST STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440-08 (NAFS-08)

FRAME DEPTH 3-1/2" Overall Frame Depth

TYPICAL WALL THICKNESS .070" Nominal

TYPICAL MAXIMUM SIZE 60" x 99" (AW), 56" x 91" (CW)

TYPICAL MINIMUM SIZE 20" x 32-1/2" (10 PSF Sill), 20" x 33-1/2" (15 PSF Sill)

TYPICAL CONFIGURATIONS

STANDARD INFILL OPTIONS 1"

STANDARD HARDWARE Heavy Duty Balances Zinc Die Cast Sweep Locks Sash Stops

OPTIONAL HARDWARE Sill Auto Lock

OTHER OPTIONS Between the Glass Muntin GridsExterior Applied Muntin Grids Perimeters and SillsExterior Pannings and Interior TrimsStructural MullionsVertically or Horizontally StackedStrap AnchorsSill for 10 PSF or 15 PSF Water PerformanceInsect Screens Nailing Fin Flange

SINGLE HUNG WINDOW PRODUCT PERFORMANCE

AirInfiltration NAFS-08

WaterResistance NAFS-08

DesignLoad

NAFS-08

Thermal Transmittance

AAMA 507 NFRC 100

Condensation Resistance* AAMA 1503

Condensation Temperature

Index* CSA A440.2

Sound Transmittance** ASTM E 1425 ASTM E 1332

≤ 0.30 Cfm/ft2 CW - 10 PSF AW - 15 PSF

50 PSF "U" Factor 0.38 to 0.57

CRF frame - 57 CRF glass - 60

I frame - 39 I glass - 58

STC - 36 OITC - 30

Note: "U" Values based on computer simulations utilizing Insulating Glass, Low E Coatings and Warm Edge Spacers. See Thermal Charts for various glass types.

* CRF and Temperature index based on high performance Low E Glass and Warm Edge Spacers.

** Acoustical test based on laminated glass.

CLASS and GRADE CLASS CW-PG50-H / AW-PG50-H

70 PSF

Page 8: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

8

EC 97911-063

1

3

2

4 5

3/8"

1-13

/16"

3-1/2"

2-7/

16"

3/8"

4-1/

4"

3/8"

2-5/8"

3-1/

2"

3/8"

3-11/16"

1

2

3

4

5

AATM3350 IsoPortTM Window JULY, 2014

ADME050

SINGLE HUNG WINDOW

TYPICAL ELEVATIONLog onto www.kawneer.com for other configurations

SCALE : 3" = 1'-0"

AATM3350 IsoPortTM SINGLE HUNG WINDOWCommercial Window, Class CW-PG50-H

HEAD

SILL10 PSF

JAMB JAMB

HORIZONTAL

D.L.O

W.D.

O.D.

D.L.O

W.D.

D.L

.O

W.D

.

O.D

.

D.L

.O

W.D

.

O.D

.

O.D.

D.L

.OD

.L.O

Page 9: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

9

EC 97911-063

1

2

4 5

3

3/8"

1-13

/16"

3-1/2"

2-7/

16"

3/8"

5-1/

4"

3/8"

2-5/8"

3-1/

2"

3/8"

3-11/16"

1

2

3

4

5

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

SINGLE HUNG WINDOW

SCALE : 3" = 1'-0"

TYPICAL ELEVATIONLog onto www.kawneer.com for other configurations

AATM3350 IsoPortTM SINGLE HUNG WINDOWArchitectural Window, Class AW-PG50-H

Class AW-PG70-H (Optional)

HEAD

JAMB JAMB

HORIZONTAL

SILL15 PSF

D.L.O

W.D.

O.D.

W.D.

O.D.

D.L.O

D.L

.OD

.L.O

D.L

.O

W.D

.

O.D

.

D.L

.O

W.D

.

O.D

.

Page 10: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

10

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

SINGLE HUNG WINDOW

HEAVY DUTY BALANCES

ZINC SWEEP LOCK AND KEEPER

AUTO LOCK

COVERED WEEPS

SASH CAMS

SASH STOPS

WEATHERING BLOCK

A class 5 adjustable spring balance with excellent operating forces capable of balancing heavier sash weights. The balanceutilizesstainlesssteelcomponentsandiscycletested for longevity.

Zinc die cast sweep locks and keepers with a durable black powder coat finish and cycle tested for longevity. Includes a push button lock feature providing added security.

An optional black rigid PVC spring operated auto lock conveniently located under the sash lift handle. The lock automatically engages the integral sill keeper upon closing the sash.

A polycarbonate weep with an integral hinged cover to allow maximum drainage of infiltrating water with a positive closing cover to block drafts and insects. The weep is available in black, white and silver finishes.

Adjustable glass filled nylon cams located left and right on the sash ensure proper alignment and smooth operation.

Black PVC sash stops are inserted into the vertical jambs without exposed fasteners to prevent excessive sash travel.

Weathering blocks located left and right at the meeting rails significantly improve resistance to air and water infiltration.

Page 11: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

11

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

DOUBLE HUNG WINDOW

For specific product applications,Consult your Kawneer representative.

Standard Features

• HighPerformanceCommercialWindow

• IsoPortTM Thermal Break

• ScrewandSplineFrameandSashCornerJoinery

• FactorySiliconeGlazed

• InteriorAppliedGlazingBead

• ArchitecturalAnodizedFinishesandAppliedCoatings

• TwoYearManufacturer'sWarranty

Double Hung Window

Exterior Interior

Thermal Break

Page 12: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

12

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

DOUBLE HUNG WINDOW

OPTIONAL CLASS and GRADE CLASS AW-PG70-H (MAXIMUM SIZE 52" x 99")

TESTING STANDARD AAMA / WDMA / CSA / 101 / I.S.2 / A440-08 (NAFS-08)

FRAME DEPTH 3-1/2" Overall Frame Depth

TYPICAL WALL THICKNESS .070" Nominal

TYPICAL MAXIMUM SIZE 60" x 99" (AW), 56" x 91" (CW)

TYPICAL MINIMUM SIZE 20" x 34" (10 PSF Sill), 20" x 35" (15 PSF Sill)

TYPICAL CONFIGURATIONS

STANDARD INFILL OPTIONS 1"

STANDARD HARDWARE Heavy Duty BalancesZinc Die Cast Sweep Locks Sash Stops Upper Sash Auto Lock

OPTIONAL HARDWARE Sill Auto Lock

OTHER OPTIONS Between the Glass Muntin GridsExterior Applied Muntin Grids Perimeters and Sills Exterior Pannings and Interior Trims Structural Mullions Vertically or Horizontally Stacked Strap Anchors Sill for 10 PSF or 15 PSF Water Performance Insect Screens Nailing Fin Flange

DOUBLE HUNG WINDOW PRODUCT PERFORMANCE

AirInfiltration NAFS-08

WaterResistance NAFS-08

DesignLoad

NAFS-08

Thermal Transmittance

AAMA 507 NFRC 100

Condensation Resistance* AAMA 1503

Condensation Temperature

Index* CSA A440.2

Sound Transmittance** ASTM E 1425 ASTM E 1332

≤ 0.30 Cfm/ft2 CW - 10 PSF AW - 15 PSF

50 PSF "U" Factor 0.39 to 0.57

CRF frame - 57 CRF glass - 60

I frame - 33 I glass - 60

STC - 34 OITC - 29

Note: "U" Values based on computer simulations utilizing Insulating Glass, Low E Coatings and Warm Edge Spacers. See Thermal Charts for various glass types.

* CRF and Temperature index based on high performance Low E Glass and Warm Edge Spacers.

** Acoustical test based on laminated glass.

CLASS and GRADE CLASS CW-PG50-H / AW-PG50-H

70 PSF

Page 13: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

13

EC 97911-063

1

3

2

4 5

3/8"

3-11

/16"

3-1/2"

2-7/

16"

3/8"

4-1/

4"

3/8"

3-11/16"

3/8"

3-11/16"

1

4

2

5

3

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

DOUBLE HUNG WINDOW

TYPICAL ELEVATIONLog onto www.kawneer.com for other configurations

SCALE : 3" = 1'-0"

AATM3350 IsoPortTM DOUBLE HUNG WINDOWCommercial Window, Class CW-PG50-H

HEAD

SILL10 PSF

JAMB JAMB

HORIZONTAL

D.L.O

W.D.

O.D.

W.D.

D.L

.O

W.D

.

O.D

.

D.L

.O

W.D

.

O.D

.

O.D.

D.L.O

D.L

.OD

.L.O

Page 14: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

14

EC 97911-063

1

3

2

4 5

3/8"

3-11

/16"

3-1/2"

2-7/

16"

3/8"

5-1/

4"

3/8"

3-11/16"

3/8"

3-11/16"

1

2

3

4

5

AATM3350 IsoPortTM Window JULY, 2014

ADME050

DOUBLE HUNG WINDOW

SCALE : 3" = 1'-0"

AATM3350 IsoPortTM DOUBLE HUNG WINDOWArchitectural Window, Class AW-PG50-H

Class AW-PG70-H (Optional)

TYPICAL ELEVATIONLog onto www.kawneer.com for other configurations

HEAD

SILL15 PSF

JAMB JAMB

HORIZONTAL

D.L.O

W.D.

O.D.

D.L.O

W.D.

D.L

.O

W.D

.

O.D

.

D.L

.O

W.D

.

O.D

.

O.D.

D.L

.OD

.L.O

Page 15: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

15

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

DOUBLE HUNG WINDOW

HEAVY DUTY BALANCES

ZINC SWEEP LOCK AND KEEPER

AUTO LOCK AND KEEPER

COVERED WEEPS

SASH CAMS

SASH STOPS

WEATHERING BLOCK

A class 5 adjustable spring balance with excellent operating forces capable of balancing heavier sash weights. The balanceutilizesstainlesssteelcomponentsandiscycletested for longevity.

Zinc die cast sweep locks and keepers with a durable black powder coat finish and cycle tested for longevity. Includes a push button lock feature providing added security.

A black rigid PVC spring operated auto lock located on the upper sash. The lock automatically engages the head keeper securing the upper sash in the closed position. The auto lock is an option for the lower sash.

A polycarbonate weep with an integral hinged cover to allow maximum drainage of infiltrating water with a positive closing cover to block drafts and insects. The weep is available in black, white and silver finishes.

Adjustable glass filled nylon cams located left and right on the sash ensure proper alignment and smooth operation.

Black PVC sash stops are inserted into the vertical jambs without exposed fasteners to prevent excessive sash travel.

Weathering blocks located left and right at the meeting rails significantly improve resistance to air and water infiltration.

Page 16: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

16

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

HORIZONTAL SLIDER

For specific product applications,Consult your Kawneer representative.

Standard Features

• HighPerformanceWindow

• IsoPortTM Thermal Break

• ScrewandSplineFrameandSashCornerJoinery

• FactorySiliconeGlazed

• InteriorAppliedGlazingBeadwithBulbGasket

• ArchitecturalAnodizedFinishesandAppliedCoatings

• TwoYearManufacturer'sWarranty

HorizontalSlidingWindow

Ext

erio

r

Inte

rior

Thermal Break

Page 17: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

17

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

CLASS and GRADE Class CW-PG50-HS / AW-PG50-HS

OPTIONAL CLASS and GRADE Class AW-PG70-HS (Max Size: 99" x 71" OX)

TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440-08 (NAFS-08)

FRAME DEPTH 3-1/2" Overall Frame Depth

TYPICAL WALL THICKNESS .070" Nominal

TYPICAL MAXIMUM SIZE 99" x 79" (OX,XO,XX) 148-1/2" x 79" (OXO,XOX)

TYPICAL MINIMUM SIZE 32" x 20" (OX,XO,XX) 48" x 20" (OXO,XOX)

TYPICAL CONFIGURATIONS

STANDARD INFILL OPTIONS 1"

STANDARD HARDWARE Composite Adjustable Tandem Roller Zinc Die Cast Sweep Lock OPTIONAL HARDWARE PVC Auto Lock

OTHER OPTIONS Between the Glass Muntin Grids Exterior Applied Muntin Grids Perimeters and Sills Exterior Pannings and Interior Trims Structural Mullions Vertically or Horizontally Stacked Sill for 10 PSF or 15 PSF Water Performance Insect Screens

HORIZONTAL SLIDER

Note: "U" Values based on computer simulations utilizing Insulating Glass, Low E Coatings and Warm Edge Spacers. See Thermal Charts for various glass types.

* CRF and Temperature index based on high performance Low E Glass and Warm Edge Spacers.

** Acoustical test based on laminated glass.

HORIZONTAL SLIDER WINDOW PRODUCT PERFORMANCE

AirInfiltration NAFS-08

WaterResistance NAFS-08

DesignLoad

NAFS-08

Thermal Transmittance

AAMA 507 NFRC 100

Condensation Resistance* AAMA 1503

Condensation Temperature

Index* CSA A440.2

Sound Transmittance** ASTM E 1425 ASTM E 1332

≤ 0.30 Cfm/ft2 CW - 10 PSF AW - 15 PSF

50 PSF "U" Factor 0.37 to 0.54

CRF frame - 66 CRF glass - 66

I frame - 45 I glass - 62

STC - 37 OITC - 2970 PSF

Page 18: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

18

EC 97911-063

1

2

5 6 7

3

43/

8"

2-5/

8"

3-1/2"

3-11

/16"

3/8"

5-1/

16"

6-1/

8"

31

2 4

5 76

2-7/16"

3-15

/32"

3/8"

2-5/8"

3/8"

3-11/16"

AATM3350 IsoPortTM Window JULY, 2014

ADME050

HORIZONTAL SLIDER

TYPICAL ELEVATIONLog onto www.kawneer.com

for other configurations

SCALE : 3" = 1'-0"

AATM3350 IsoPortTM OX HORIZONTAL SLIDER

Commercial Window,Class CW-PG50-HS

HEAD WITHFIXED SASH

SILL WITHFIXED SASH

(10 PSF)

FIXED SASHJAMB

INTERLOCK OPERABLE SASHJAMB

HEAD WITHOPERABLE

SASH

SILL WITHOPERABLE

SASH(10 PSF)

D.L.O

W.D.

O.D.

D.L.O

W.D.

D.L

.O

W.D

.

O.D

.

O.D.

D.L.OD.L.O

D.L

.O

W.D

.

O.D

.

Page 19: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

19

EC 97911-063

1

5 6

2

7

3

4

3/8"

2-5/

8"

3-1/2"

3-11

/16"

3/8"

6-1/

16"

7-1/

8"

31

2 4

5 76

2-7/16"

3-15

/32"

3/8"

2-5/8"

3/8"

3-11/16"

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

HORIZONTAL SLIDER

TYPICAL ELEVATIONLog onto www.kawneer.com

for other configurations

SCALE : 3" = 1'-0"

AATM3350 IsoPortTM OX HORIZONTAL SLIDER

Architectural Window, Class AW-PG50-HS

Class AW-PG70-HS (Optional)

HEAD WITHFIXED SASH

FIXED SASHJAMB

INTERLOCK

SILL WITHFIXED SASH

(15 PSF)

OPERABLE SASHJAMB

HEAD WITHOPERABLE

SASH

SILL WITHOPERABLE

SASH(15 PSF)

D.L.O

W.D.

O.D.

D.L.O

W.D.

D.L

.O

W.D

.

O.D

.

D.L

.O

W.D

.

O.D

.

O.D.

D.L.OD.L.O

Page 20: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

20

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

HORIZONTAL SLIDER

COMPOSITE ADJUSTABLE TANDEM ROLLER

Glassfillednylonhousing,diecastzamakrollersupport,precisionsealed ball bearing rollers with nylon tires.

ZINC SWEEP LOCK AND KEEPER

PVC AUTO LOCK AND KEEPER

COVERED WEEP

SASH STOPS

Zinc die cast sweep locks and keepers with a durable black powder coat finish and cycle tested for longevity. Includes a push button lock feature providing added security.

A black rigid PVC, spring operated auto lock, located on the jamb. The lock automatically engages the jamb keeper securing the sash in the closed position. The auto lock is standard for the exterior sash of the XX configuration only.

A polycarbonate weep with an integral hinged cover to allow maximum drainage of infiltrating water with a positive closing cover to block drafts and insects. The weep is available in black, white and silver finishes.

Black PVC sash stops are inserted into the head without exposed fasteners to prevent excessive sash travel.

Page 21: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

21

EC 97911-063

543200

1

2

3

4

5

1.0

1

1.0A

CB

DE

543200

1

2

3

4

5

1.0

1

1.0A

CB

DE

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

WIND LOAD CHARTS

A = 40 PSF (1915)B = 50 PSF (2394)C = 60 PSF (2873)D = 70 PSF (3352)E = 80 PSF (3830)

HORIZONTAL WIDTH IN FEET

SA

SH

HE

IGH

T IN

FE

ET

HORIZONTAL WIDTH IN METERS

SA

SH

HE

IGH

T IN

ME

TER

S

SINGLE HUNG INTERMEDIATE CW-RATED

WIND LOAD CHARTS:THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 psi (104 MPa). If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves.

SINGLE HUNG INTERMEDIATE AW-RATED

HORIZONTAL WIDTH IN FEET

SA

SH

HE

IGH

T IN

FE

ET

HORIZONTAL WIDTH IN METERS

SA

SH

HE

IGH

T IN

ME

TER

S

Page 22: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

22

EC 97911-063

54321

2

3

4

5

6

72.0

1.0

1

1.0

8

A

CB

DE

54321

2

3

4

5

6

72.0

1

1.0

8

1.0

A

CB

DE

AATM3350 IsoPortTM Window JULY, 2014

ADME050

WIND LOAD CHARTS

A = 40 PSF (1915)B = 50 PSF (2394)C = 60 PSF (2873)D = 70 PSF (3352)E = 80 PSF (3830)

MUNTIN CENTERS IN FEET

MU

NTI

N H

EIG

HT

IN F

EE

T

MUNTIN CENTERS IN METERS

MU

NTI

N H

EIG

HT

IN M

ETE

RS

WITH HORIZONTALS

TRUE MUNTIN FOR FIXED WINDOW

TRUE MUNTIN FOR FIXED WINDOW

MUNTIN CENTERS IN FEET

MU

NTI

N H

EIG

HT

IN F

EE

T

MUNTIN CENTERS IN METERS

MU

NTI

N H

EIG

HT

IN M

ETE

RS

WITHOUT HORIZONTALS

WIND LOAD CHARTS:THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 psi (104 MPa). If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves.

Page 23: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

23

EC 97911-063

543202

3

4

5

6

72.0

1.0

1

1.0

8

9

B

A

C

D

A

CB

DE

5432102

3

4

5

6

7

8

9

10

1.0

3.0

2.0

1.0

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

MULLION CENTERS IN FEET

MU

LLIO

N H

EIG

HT

IN F

EE

T

MULLION CENTERS IN METERS

MU

LLIO

N H

EIG

HT

IN M

ETE

RS

DEEP THREE PIECE MULLION

MULLION CENTERS IN FEET

MU

LLIO

N H

EIG

HT

IN F

EE

T

MULLION CENTERS IN METERS

MU

LLIO

N H

EIG

HT

IN M

ETE

RS

SHALLOW THREE PIECE MULLION

A = 30 PSF (1436)B = 40 PSF (1915)C = 50 PSF (2394)D = 60 PSF (2873)

WIND LOAD CHARTS

A = 40 PSF (1915)B = 50 PSF (2394)C = 60 PSF (2873)D = 70 PSF (3352)E = 80 PSF (3830)

WIND LOAD CHARTS:THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 psi (104 MPa). If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves.

Page 24: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

24

EC 97911-063

954321

2

3

4

5

6

72.0

1.0

1

1.0

8

9

76 8

2.0

A

C

B

DE

954321

2

3

4

5

6

72.0

1.0

1

1.0

8

9

76 8

2.0

A

CB

D E

AATM3350 IsoPortTM Window JULY, 2014

ADME050

WIND LOAD CHARTS

A = 20 PSF (958)B = 35 PSF (1676)C = 50 PSF (2394)D = 65 PSF (3112)E = 80 PSF (3830)

MUNTIN CENTERS IN FEET

MU

NTI

N H

EIG

HT

IN F

EE

T

MUNTIN CENTERS IN METERS

MU

NTI

N H

EIG

HT

IN M

ETE

RS

WITH HORIZONTALS

VERTICAL STACK JAMBS FIXED / FIXED

VERTICAL STACK JAMBS FIXED / DOUBLE HUNG

MUNTIN CENTERS IN FEET

MU

NTI

N H

EIG

HT

IN F

EE

T

MUNTIN CENTERS IN METERS

MU

NTI

N H

EIG

HT

IN M

ETE

RS

A = 20 PSF (958)B = 35 PSF (1676)C = 50 PSF (2394)D = 65 PSF (3112)E = 80 PSF (3830)

WITH HORIZONTALS

WIND LOAD CHARTS:THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 psi (104 MPa). If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves.

Page 25: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

25

EC 97911-063

954321

2

3

4

5

6

72.0

1.0

1

1.0

8

9

76 8

2.0

A

C

B

DE

954321

2

3

4

5

6

72.0

1.0

1

1.0

8

9

76 8

2.0

A

B

CDE

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

WIND LOAD CHARTS

MUNTIN CENTERS IN FEET

MU

NTI

N H

EIG

HT

IN F

EE

T

MUNTIN CENTERS IN METERS

MU

NTI

N H

EIG

HT

IN M

ETE

RS

WITH HORIZONTALS

VERTICAL STACK JAMBS FIXED / SINGLE HUNG

VERTICAL STACK JAMBS DOUBLE HUNG / DOUBLE HUNG

MUNTIN CENTERS IN FEET

MU

NTI

N H

EIG

HT

IN F

EE

T

MUNTIN CENTERS IN METERS

MU

NTI

N H

EIG

HT

IN M

ETE

RS

A = 20 PSF (958)B = 35 PSF (1676)C = 50 PSF (2394)D = 65 PSF (3112)E = 80 PSF (3830)

A = 20 PSF (958)B = 35 PSF (1676)C = 50 PSF (2394)D = 65 PSF (3112)E = 80 PSF (3830)

WITH HORIZONTALS

WIND LOAD CHARTS:THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 psi (104 MPa). If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves.

Page 26: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

26

EC 97911-063

954321

2

3

4

5

6

72.0

1.0

1

1.0

8

9

76 8

2.0

A

C

B

DE

AATM3350 IsoPortTM Window JULY, 2014

ADME050

WIND LOAD CHARTS

MUNTIN CENTERS IN FEET

MU

NTI

N H

EIG

HT

IN F

EE

T

MUNTIN CENTERS IN METERS

MU

NTI

N H

EIG

HT

IN M

ETE

RS

WITH HORIZONTALS

VERTICAL STACK JAMBS SINGLE HUNG / SINGLE HUNG

A = 20 PSF (958)B = 35 PSF (1676)C = 50 PSF (2394)D = 65 PSF (3112)E = 80 PSF (3830)

WIND LOAD CHARTS:THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 psi (104 MPa). If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves.

Page 27: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

27

EC 97911-063

954321

2

3

4

5

6

72.0

1.0

1

1.0

8

9

76 8

2.0

A

CB

DE

954321

2

3

4

5

6

72.0

1.0

1

1.0

8

9

76 8

2.0

A

C

B

DE

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

WIND LOAD CHARTS

A = 40 PSF (1915)B = 50 PSF (2394)C = 60 PSF (2873)D = 70 PSF (3352)E = 80 PSF (3830)

MODULE CENTERS IN FEET

SA

SH

HE

IGH

T IN

FE

ET

MODULE CENTERS IN METERS

SA

SH

HE

IGH

T IN

ME

TER

S

LOCK STILEHORIZONTAL SLIDER

MODULE CENTERS IN FEET

SA

SH

HE

IGH

T IN

FE

ET

MODULE CENTERS IN METERS

SA

SH

HE

IGH

T IN

ME

TER

S

LOCK STILEHORIZONTAL SLIDER

WITHOUT HORIZONTALS

WITHOUT HORIZONTALS

WIND LOAD CHARTS:THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 psi (104 MPa). If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves.

Page 28: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

28

EC 97911-063

954321

2

3

4

5

6

72.0

1.0

1

1.0

8

9

76 8

2.0

A

C

B

DE

954321

2

3

4

5

6

72.0

1.0

1

1.0

8

9

76 8

2.0

A

C

B

DE

AATM3350 IsoPortTM Window JULY, 2014

ADME050

WIND LOAD CHARTSW

IND

OW

HE

IGH

T IN

FE

ET

WIN

DO

W H

EIG

HT

IN M

ETE

RS

VERTICAL STACK JAMBS HORIZONTAL SLIDER

A = 20 PSF (958)B = 35 PSF (1676)C = 50 PSF (2394)D = 65 PSF (3112)E = 80 PSF (3830)

WIN

DO

W H

EIG

HT

IN F

EE

T

WIN

DO

W H

EIG

HT

IN M

ETE

RS "XX" VERTICAL STACK JAMBS

HORIZONTAL SLIDER

MODULE CENTERS IN FEET

MODULE CENTERS IN METERS

MODULE CENTERS IN FEET

MODULE CENTERS IN METERS

WITHOUT HORIZONTALS

WITHOUT HORIZONTALS

WIND LOAD CHARTS:THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 psi (104 MPa). If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves.

Page 29: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

29

EC 97911-063

0

1

2

3

4

5

0

2.0

1.0

1.0

7

8

6

1 2 3 4 5 6

A

CB

0

1

2

3

4

5

0

2.0

1.0

1.0

7

8

6

1 2 3 4 5 6

A

CB

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

DEADLOAD CHARTS

DEADLOAD CHARTS:HORIZONTAL DEADLOAD LIMITATIONS ARE BASED UPON 1/8" (3.2) MAXIMUM ALLOWABLE DEFLECTION AT THE CENTER OF AN INTERMEDIATE HORIZONTAL MEMBER. THE ACCOMPANyING CHARTS ARE CALCULATED FOR THE GLASS TyPES INDICATED SUPPORTED ON TWO SETTING BLOCKS AT EIGHT POINT LOADING BUT NO MORE THAN 6" FROM THE EDGE OF GLASS.

GLASS TYPE:A = 1/8" - 3/4" A.S. - 1/8"B = 3/16" - 5/8" A.S. - 3/16"C = 1/4" - 1/2" A.S. - 1/4"

SINGLE HUNG OR DOUBLE HUNG HORIZONTAL

TRUE HORIZONTAL MUNTIN FOR FIXED WINDOW

HORIZONTAL WIDTH IN FEET

GLA

ZIN

G H

EIG

HT

IN F

EE

T

HORIZONTAL WIDTH IN METERS

GLA

ZIN

G H

EIG

HT

IN M

ETE

RS

HORIZONTAL WIDTH IN FEET

GLA

ZIN

G H

EIG

HT

IN F

EE

T

HORIZONTAL WIDTH IN METERS

GLA

ZIN

G H

EIG

HT

IN M

ETE

RS

GLASS TYPE:A = 1/8" - 3/4" A.S. - 1/8"B = 3/16" - 5/8" A.S. - 3/16"C = 1/4" - 1/2" A.S. - 1/4"

Page 30: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

30

EC 97911-063

1-13

/16"

4-3/8"

335226

5/8"

4-1/4"

1-5/

16"

325059

335225

1-5/16"

4-1/

4"

325059

335225

3-1/2"260475

260100

335400 335400

335306246501246500

335400

335471

335472

AATM3350 IsoPortTM Window JULY, 2014

ADME050

RECEPTORS, SUB SILLS AND ANCHORING

TYPICAL RECEPTOR SYSTEM

HEADRECEPTOR

(Interior Installation)

JAMBRECEPTOR

(Interior Installation)

FULL DEPTHSILL

SCALE : 3" = 1'-0"

STRAP ANCHORWITH FIXED WINDOW

STRAP ANCHORWITH HUNG WINDOW

ANCHORING

FLANGE / NAILING FINUNEQUAL LEG SILL INTERIOR SNAP TRIM

ANCHORING

PVC PERIMETER(Typical at Head and Jamb of XO/OX/XOX/OXO Slider and

Female Stack Jambs of Single Hung similar)

PVC PERIMETER(Head and Jamb of XX Slider and Female Stack Jambs of

Double Hung similar)

STRAP ANCHOR WITH HORIZONTAL SLIDER

Page 31: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

31

EC 97911-063

3'-0"

5'-0

"

(915)

(152

4)

32-3/8"(822)

56-3

/8"

(143

2)

0.48 (2.73)

0.46 (2.61)

0.44 (2.50)

0.42 (2.39)

0.40 (2.27)

0.38 (2.16)

0.36 (2.05)

0.34 (1.93)

0.32 (1.82)

0.30 (1.71)

0.28 (1.59)

0.26 (1.48)

0.24 (1.37)

0.22 (1.25)

0.20 (1.14)

0.70

0.80

0.60

0.50

0.40

0.30

0.20

0.75

0.65

0.55

0.45

0.35

0.25

(4.00)

(4.50)

(3.50)

(3.00)

(2.50)

(1.50)

(2.00)

0.90

0.85

(5.00)

0.44

0.85

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

FIXED WINDOW THERMAL CHARTS

Project Specific U-Factor Example Calculation

ExampleGlassU-Factor =0.42Btu/hr•ft2•°F

TotalDaylightOpening =32-3/8"•56-3/8"=12.67ft2

TotalProjectedArea =3'-0"•5'-0"=15ft2

Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (12.67 ÷ 15)100 = 85%

System U-factor vs Percent of Glass Area

Based on 85% glass and center of glass (COG) U-factor of 0.42SystemU-factorisequalto0.44Btu/hr•ft2•°F

Percent of Glass Area

EXAMPLE

NOT FOR DESIGN

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

Wm

2 •

°CS

yste

m U

-fac

tor

COGU-factor

Page 32: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

32

EC 97911-063

0.70

0.80

0.60

0.50

0.40

0.30

0.20

0.75

0.65

0.55

0.45

0.35

0.25

(4.00)

(4.50)

(3.50)

(3.00)

(2.50)

(1.50)

(2.00)

0.90

0.85

(5.00)

0.48 (2.73)

0.46 (2.61)

0.44 (2.50)

0.42 (2.39)

0.40 (2.27)

0.38 (2.16)

0.36 (2.05)

0.34 (1.93)

0.32 (1.82)

0.30 (1.71)

0.28 (1.59)

0.26 (1.48)

0.24 (1.37)

0.22 (1.25)

0.20 (1.14)

AATM3350 IsoPortTM Window JULY, 2014

ADME050

FIXED WINDOW THERMAL CHARTS

System U-factor vs Percent of Glass Area

Notes for System U-factor, SHGC and VT charts:For glass values that are not listed, linear interpolation is permitted.Glass properties are based on center of glass values and are obtained from your glass supplier.

Percent of Glass Area = Vision Area/Total AreaDaylight Opening / Projected Area

COGU-factor

AATM3350 IsoPortTM FIXED WINDOW

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

Wm

2 •

°CS

yste

m U

-fac

tor

Note:Values in parentheses are metric.COG = Center of Glass.Charts are generated per AMMA 507

Page 33: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

33

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

FIXED WINDOW THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Vision Area / Total Area (%)

COGSHGC

Sys

tem

SH

GC

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Area / Total Area (%)

COGVT

Sys

tem

VT

AATM3350 IsoPortTM FIXED WINDOW

Page 34: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

34

EC 97911-063

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.65

0.61

0.57

0.53

0.48

0.44

0.40

0.35

0.31

0.27

0.23

0.18

0.14

0.10

0.05

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.56

0.54

0.52

0.51

0.49

0.48

0.46

0.44

0.43

0.41

0.40

0.38

0.36

0.35

0.33

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.64

0.60

0.56

0.51

0.47

0.43

0.39

0.34

0.30

0.26

0.21

0.17

0.13

0.09

0.04

AATM3350 IsoPortTM Window JULY, 2014

ADME050

NOTE: For glass values that are not listed, linear interpolation is permitted.1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4.OverallU-Factor,SHGC,andVTMatriciesarebasedonthestandardNFRCspecimensizeof 1200mm wide by 1500mm high (47-1/4" by 59-1/16").

Thermal Transmittance1 (BTU/hr• ft 2•°F)

SHGC Matrix 2 Visible Transmittance 2

FIXED WINDOW THERMAL PERFORMANCE MATRIX (NFRC SIZE)

Glass U-Factor 3 Overall U-Factor 4

Glass SHGC 3 Overall Glass U-Factor 4 Glass VT 3 Overall VT 4

AATM3350 IsoPortTM FIXED WINDOW

Page 35: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

35

EC 97911-063

30-3/4"

5'-0

"

(781)

(152

4)

28-5/8"(727)

25-3

/4"

(654

)25

-3/4

"(6

54)

3'-0"(915)

0.51

71%

0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20

0.70

0.80

0.60

0.50

0.40

0.30

0.2075 70 65 60 55 50

0.75

0.65

0.55

0.45

0.35

0.25

(2.73)(2.61)(2.50)(2.39)(2.27)(2.16)(2.05)(1.93)(1.82)(1.71)(1.59)(1.48)(1.37)(1.25)(1.14)

(4.00)

(4.50)

(3.50)

(3.00)

(2.50)

(1.50)

(2.00)

0.90

0.85(5.00)

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

SINGLE HUNG THERMAL CHARTS

ExampleGlassU-Factor =0.42Btu/hr•ft2•°F

TotalDaylightOpening =(30-3/4"•25-3/4")+(28-5/8"•25-3/4")=10.62ft2

TotalProjectedArea =3'-0"•5'-0"=15ft2

Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (10.62 ÷ 15)100 = 71%

System U-factor vs Percent of Glass Area

Based on 71% glass and center of glass (COG) U-factor of 0.42SystemU-factorisequalto0.51Btu/hr•ft2•°F

Percent of Glass Area

COGU-factor

EXAMPLE

NOT FOR DESIGN

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

Wm

2 •

°CS

yste

m U

-fac

tor

Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines)

Page 36: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

36

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

SINGLE HUNG THERMAL CHARTS

System U-factor vs Percent of Glass Area

Notes for System U-factor, SHGC and VT charts:For glass values that are not listed, linear interpolation is permitted.Glass properties are based on center of glass values and are obtained from your glass supplier.

Percent of Glass Area = Vision Area/Total AreaDaylight Opening / Projected Area

COGU-factor

AATM3350 IsoPortTM SINGLE HUNG WINDOW

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

Note:Values in parentheses are metric.COG = Center of Glass.Charts are generated per AMMA 507

Page 37: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

37

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

SINGLE HUNG THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Vision Area / Total Area (%)

COGSHGC

AATM3350 IsoPortTM SINGLE HUNG WINDOW

Sys

tem

SH

GC

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Area / Total Area (%)

COGVT

Sys

tem

VT

Page 38: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

38

EC 97911-063

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.57

0.55

0.54

0.53

0.51

0.50

0.49

0.47

0.46

0.45

0.43

0.42

0.40

0.39

0.38

0.47

0.45

0.44

0.42

0.41

0.40

0.39

0.37

0.35

0.34

AATM3350 IsoPortTM Window JULY, 2014

ADME050

Thermal Transmittance1 (BTU/hr• ft 2•°F)

SINGLE HUNG THERMAL PERFORMANCE MATRIX (NFRC SIZE)

Glass U-Factor 3 Overall U-Factor 4

AATM3350 IsoPortTM SINGLE HUNG WINDOWW

ith

War

m E

dg

e S

pac

erW

ith

Alu

min

um

Sp

acer

Page 39: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

39

EC 97911-063

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.57

0.53

0.49

0.46

0.42

0.38

0.34

0.31

0.27

0.23

0.20

0.16

0.12

0.08

0.05

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.56

0.52

0.48

0.45

0.41

0.37

0.33

0.30

0.26

0.22

0.19

0.15

0.11

0.07

0.04

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

NOTE: For glass values that are not listed, linear interpolation is permitted.1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4.OverallU-Factor,SHGC,andVTMatriciesarebasedonthestandardNFRCspecimensizeof 1200mm wide by 1500mm high (47-1/4" by 59-1/16").

SHGC Matrix 2 Visible Transmittance 2

Glass SHGC 3 Overall Glass U-Factor 4 Glass VT 3 Overall VT 4

SINGLE HUNG THERMAL PERFORMANCE MATRIX (NFRC SIZE)

AATM3350 IsoPortTM SINGLE HUNG WINDOW

Page 40: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

40

EC 97911-063

28-5/8"

5'-0

"

(727)

(152

4)

28-5/8"(727)

24-3

1/32

"(6

34)

24-3

1/32

"(6

34)

3'-0"(915)

0.55

61%

0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20

0.70

0.80

0.60

0.50

0.40

0.30

0.2075 70 65 60 55 50

0.75

0.65

0.55

0.45

0.35

0.25

(2.73)(2.61)(2.50)(2.39)(2.27)(2.16)(2.05)(1.93)(1.82)(1.71)(1.59)(1.48)(1.37)(1.25)(1.14)

(4.00)

(4.50)

(3.50)

(3.00)

(2.50)

(1.50)

(2.00)

0.90

0.85(5.00)

AATM3350 IsoPortTM Window JULY, 2014

ADME050

DOUBLE HUNG THERMAL CHARTS

Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines)

ExampleGlassU-Factor =0.42Btu/hr•ft2•°F

TotalDaylightOpening =(28-5/8"•24-31/32")+(28-5/8"•24-31/32")=9.21ft2

TotalProjectedArea =3'-0"•5'-0"=15ft2

Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (9.21 ÷ 15)100 = 61%

System U-factor vs Percent of Glass Area

Based on 61% glass and center of glass (COG) U-factor of 0.42SystemU-factorisequalto0.55Btu/hr•ft2•°F

Percent of Glass Area

COGU-factor

EXAMPLE

NOT FOR DESIGN

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

Wm

2 •

°CS

yste

m U

-fac

tor

Page 41: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

41

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

System U-factor vs Percent of Glass Area

Notes for System U-factor, SHGC and VT charts:For glass values that are not listed, linear interpolation is permitted.Glass properties are based on center of glass values and are obtained from your glass supplier.

Percent of Glass Area = Vision Area/Total AreaDaylight Opening / Projected Area

COGU-factor

AATM3350 IsoPortTM DOUBLE HUNG WINDOW

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

Note:Values in parentheses are metric.COG = Center of Glass.Charts are generated per AMMA 507

DOUBLE HUNG THERMAL CHARTS

Page 42: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

42

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

DOUBLE HUNG THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Vision Area / Total Area (%)

COGSHGC

AATM3350 IsoPortTM DOUBLE HUNG WINDOW

Sys

tem

SH

GC

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Area / Total Area (%)

COGVT

Sys

tem

VT

Page 43: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

43

EC 97911-063

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.57

0.56

0.55

0.53

0.52

0.51

0.50

0.48

0.47

0.46

0.44

0.43

0.42

0.41

0.39

0.48

0.46

0.45

0.44

0.42

0.41

0.40

0.38

0.37

0.36

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

DOUBLE HUNG THERMAL PERFORMANCE MATRIX (NFRC SIZE)

Thermal Transmittance1 (BTU/hr• ft 2•°F)

Glass U-Factor 3 Overall U-Factor 4

AATM3350 IsoPortTM DOUBLE HUNG WINDOW

Wit

h W

arm

Ed

ge

Sp

acer

Wit

h A

lum

inu

m S

pac

er

Page 44: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

44

EC 97911-063

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.54

0.50

0.47

0.43

0.40

0.39

0.33

0.29

0.26

0.22

0.19

0.15

0.12

0.08

0.05

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.53

0.49

0.46

0.42

0.39

0.35

0.32

0.28

0.25

0.21

0.18

0.14

0.11

0.07

0.04

AATM3350 IsoPortTM Window JULY, 2014

ADME050

NOTE: For glass values that are not listed, linear interpolation is permitted.1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4.OverallU-Factor,SHGC,andVTMatriciesarebasedonthestandardNFRCspecimensizeof 1200mm wide by 1500mm high (47-1/4" by 59-1/16").

SHGC Matrix 2 Visible Transmittance 2

Glass SHGC 3 Overall Glass U-Factor 4 Glass VT 3 Overall VT 4

DOUBLE HUNG THERMAL PERFORMANCE MATRIX (NFRC SIZE)

AATM3350 IsoPortTM DOUBLE HUNG WINDOW

Page 45: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

45

EC 97911-063

26-3

/16"

5'-0"

(665

)

(1524)

28-5

/16"

(719

)

25-5/8"(651)

25-5/8"(651)

3'-0

"(9

15)

0.53

65%

0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20

0.70

0.80

0.60

0.50

0.40

0.30

0.2075 70 65 60 55 50

0.75

0.65

0.55

0.45

0.35

0.25

(2.73)(2.61)(2.50)(2.39)(2.27)(2.16)(2.05)(1.93)(1.82)(1.71)(1.59)(1.48)(1.37)(1.25)(1.14)

(4.00)

(4.50)

(3.50)

(3.00)

(2.50)

(1.50)

(2.00)

0.90

0.85(5.00)

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

OX HORIZONTAL SLIDER THERMAL CHARTS

Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines)

ExampleGlassU-Factor =0.42Btu/hr•ft2•°F

TotalDaylightOpening =(25-5/8"•28-5/16")+(25-5/8"•26-3/16")=9.70ft2

TotalProjectedArea =3'-0"•5'-0"=15ft2

Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (9.70 ÷ 15)100 = 65%

System U-factor vs Percent of Glass Area

Based on 65% glass and center of glass (COG) U-factor of 0.42SystemU-factorisequalto0.53Btu/hr•ft2•°F

Percent of Glass Area

COGU-factor

EXAMPLE

NOT FOR DESIGN

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

Wm

2 •

°CS

yste

m U

-fac

tor

Page 46: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

46

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

OX HORIZONTAL SLIDER THERMAL CHARTS

System U-factor vs Percent of Glass Area

Notes for System U-factor, SHGC and VT charts:For glass values that are not listed, linear interpolation is permitted.Glass properties are based on center of glass values and are obtained from your glass supplier.

Percent of Glass Area = Vision Area/Total AreaDaylight Opening / Projected Area

COGU-factor

AATM3350 IsoPortTM OX HORIZONTAL SLIDER WINDOW

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

Note:Values in parentheses are metric.COG = Center of Glass.Charts are generated per AMMA 507

Page 47: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

47

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

OX HORIZONTAL SLIDER THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Vision Area / Total Area (%)

COGSHGC

AATM3350 IsoPortTM OX HORIZONTAL SLIDER WINDOW

Sys

tem

SH

GC

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Area / Total Area (%)

COGVT

Sys

tem

VT

Page 48: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

48

EC 97911-063

0.47

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.54

0.53

0.52

0.50

0.49

0.48

0.47

0.46

0.44

0.43

0.42

0.41

0.39

0.38

0.37

0.35

0.34

0.33

0.32

0.30

AATM3350 IsoPortTM Window JULY, 2014

ADME050

Thermal Transmittance1 (BTU/hr• ft 2•°F)

OX HORIZONTAL SLIDER THERMAL PERFORMANCE MATRIX (NFRC SIZE)

Glass U-Factor 3 Overall U-Factor 4

AATM3350 IsoPortTM OX HORIZONTAL SLIDER WINDOWW

ith

Alu

min

um

Sp

acer

Page 49: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

49

EC 97911-063

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.53

0.50

0.46

0.43

0.39

0.36

0.32

0.29

0.25

0.22

0.18

0.15

0.11

0.08

0.04

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.52

0.49

0.45

0.42

0.38

0.35

0.31

0.28

0.24

0.21

0.17

0.14

0.10

0.07

0.03

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

NOTE: For glass values that are not listed, linear interpolation is permitted.1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4.OverallU-Factor,SHGC,andVTMatriciesarebasedonthestandardNFRCspecimensizeof 1500mm wide by 1200mm high (59-1/16" by 47-1/4").

SHGC Matrix 2 Visible Transmittance 2

Glass SHGC 3 Overall Glass U-Factor 4 Glass VT 3 Overall VT 4

OX HORIZONTAL SLIDER THERMAL PERFORMANCE MATRIX (NFRC SIZE)

AATM3350 IsoPortTM OX HORIZONTAL SLIDER WINDOW

Page 50: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

50

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

XX HORIZONTAL SLIDER THERMAL CHARTS

System U-factor vs Percent of Glass Area

Notes for System U-factor, SHGC and VT charts:For glass values that are not listed, linear interpolation is permitted.Glass properties are based on center of glass values and are obtained from your glass supplier.

Percent of Glass Area = Vision Area/Total AreaDaylight Opening / Projected Area

COGU-factor

AATM3350 IsoPortTM XX HORIZONTAL SLIDER WINDOW

Btu

hr

• ft

2 •

°FS

yste

m U

-fac

tor

Note:Values in parentheses are metric.COG = Center of Glass.Charts are generated per AMMA 507

Page 51: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

51

EC 97911-063

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

XX HORIZONTAL SLIDER THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Vision Area / Total Area (%)

COGSHGC

AATM3350 IsoPortTM XX HORIZONTAL SLIDER WINDOW

Sys

tem

SH

GC

System Visible Transmittance (VT) vs Percent of Vision Area

Vision Area / Total Area (%)

COGVT

Sys

tem

VT

Page 52: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

52

EC 97911-063

0.47

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.56

0.55

0.54

0.52

0.51

0.50

0.49

0.48

0.47

0.45

0.44

0.43

0.42

0.41

0.40

0.38

0.37

0.36

0.35

0.34

AATM3350 IsoPortTM Window JULY, 2014

ADME050

Thermal Transmittance1 (BTU/hr• ft 2•°F)

XX HORIZONTAL SLIDER THERMAL PERFORMANCE MATRIX (NFRC SIZE)

Glass U-Factor 3 Overall U-Factor 4

AATM3350 IsoPortTM XX HORIZONTAL SLIDER WINDOWW

ith

Alu

min

um

Sp

acer

Page 53: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

53

EC 97911-063

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.51

0.47

0.44

0.41

0.37

0.34

0.31

0.28

0.24

0.21

0.18

0.14

0.11

0.08

0.04

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.50

0.46

0.43

0.40

0.36

0.33

0.30

0.26

0.23

0.20

0.17

0.13

0.10

0.07

0.03

AATM3350 IsoPortTM WindowJULY, 2014

ADME050

NOTE: For glass values that are not listed, linear interpolation is permitted.1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4.OverallU-Factor,SHGC,andVTMatriciesarebasedonthestandardNFRCspecimensizeof 1500mm wide by 1200mm high (59-1/16" by 47-1/4").

SHGC Matrix 2 Visible Transmittance 2

Glass SHGC 3 Overall Glass U-Factor 4 Glass VT 3 Overall VT 4

XX HORIZONTAL SLIDER THERMAL PERFORMANCE MATRIX (NFRC SIZE)

AATM3350 IsoPortTM XX HORIZONTAL SLIDER WINDOW

Page 54: ULY, 2014 AATM3350 IsoPort Window 1 · FIXED WINDOW FIXED WINDOW PRODUCT PERFORMANCE Air Infiltration NAFS-08 Water Resistance NAFS-08 Design Load NAFS-08 Thermal Transmittance AAMA

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

4

kawneer.com

54

EC 97911-063

AATM3350 IsoPortTM Window JULY, 2014

ADME050

BLANK PAGE