Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Trusted Heating Solutions
January 2020
..............................................................................................
..............................................................................................
RTUPackaged Air Conditioning Unit
Packaged Air Conditioning Unit.........................................................................................................
.........................................................................................................
RTU
Controls
The Reznor RTU series is a range of packaged Air Conditioning units, providing cooling and heating.
Reznor's range of high efficiency packaged rooftop units are available in cooling only and reversible modes. Both are available with energy recovery function as an option.
Model RangeRTU units come in 27 different models with
cooling and heat pump capacities ranging
from 20 to 300 kW.
Features & Benefits • Acoustic jackets combined with
insulated compressor compartments
• Low noise variable speed condenser fans providing energy efficient operation and head pressure control
• Plug and play controls, compatible with a range of BMS protocols including Modbus, and BACnet
• Optimised design for R410A refrigerant
• High energy efficiency at both full and part load operation to reduce operating costs
• Low noise levels achieved through
high performance fans and use
of anti-vibration blocks for the compressor and refrigeration circuit assembly
• Centrifugal fans with optional EC plug fans for both supply and
exhaust airflow
• Active heat recovery option available
to provide enhanced cooling and
heatpump performance
• Optional gas fired heating sections
to increase seasonal efficiency
The Reznor RTU utilises Carel Microproces-
sor Controls to provide automatic operation
of cooling, ventilation, heating and heat
recovery operation. Additional control op-
tions inlcude :
• Remote control operation
• Temperature and/or humidity
sensors (up to 6 units)
• Energy analyser
• Variable speed EC fans
• Damper actuators
• Electronic Expansion Valves driver
modules
• Digital-scroll or Inverter Compressor
driver modules
• CO2 or VOC sensors and control
Controls
Packaged Air Conditioning Unit.......................................................
.......................................................
Energy Efficiency - Multiscroll Technology
Multiscroll technology combined with
electronic expansion valves (EEV) and
EC plug fans increase the system energy
efficiency and provide a resilient and reliable
solution.
Thanks to the RTU's ability to produce its
output in smaller increments, spaces with
a variable occupancy rate and changing
conditions during the day, such as shopping
centres, can benefit from energy savings up
to 30%.
The seasonal efficiency of multiscroll units
in tandem from four scroll AC compressors
is similar to the equipment with inverter
compressors. For units with less than four
compressors, high ESEER is achieved thanks
to Digital Scroll technology with refrigerant
flow control.
Comfort - Air Quality and Low Level Noise
The RTU range of units come equipped
as standard with high efficiency G4 class
air filters. Fresh air & ventilation options
provide a high level of indoor air quality
and help ensure a clean and comfortable air
conditioned space.
Optional pre-filters and F6 to F9 filters can
be provided.
The RTU rooftop can be equipped with
Axitop diffusers for the outdoor fans,
improving operational efficiency and
lowering noise levels.
m3/h
22 00021 00020 00019 00018 00017 00016 00015 000
dB(A)
90
85
80
75
70
-4,9 dB(A)
+9%
Up to 30% of savings
IDA 3Commercial
buildings
IDA 4industrial buil-
dings
Ventilation minimum Flow
8 l/s pers.0,55 l/s m 2
5 l/s pers.0,28 l/s m 2
Filtration ODA 1Pure outdoor air F7 F5
Filtration ODA 2 Outdoor air with high particle concentrations or contaminant
F5 + F7 F5 + F6
Filtration ODA 3Outdoor air with high particle concentrations or contaminant
F5 + F7 F5 + F6
Δ
m3/h
22 00021 00020 00019 00018 00017 00016 00015 000
dB(A)
90
85
80
75
70
-4,9 dB(A)
+9%
Up to 30% of savings
IDA 3Commercial
buildings
IDA 4industrial buil-
dings
Ventilation minimum Flow
8 l/s pers.0,55 l/s m 2
5 l/s pers.0,28 l/s m 2
Filtration ODA 1Pure outdoor air F7 F5
Filtration ODA 2 Outdoor air with high particle concentrations or contaminant
F5 + F7 F5 + F6
Filtration ODA 3Outdoor air with high particle concentrations or contaminant
F5 + F7 F5 + F6
Δ
Multiscroll technology +
Electronic Plug-fan
Standard
m3/h
22 00021 00020 00019 00018 00017 00016 00015 000
dB(A)
90
85
80
75
70
-4,9 dB(A)
+9%
Up to 30% of savings
IDA 3Commercial
buildings
IDA 4industrial buil-
dings
Ventilation minimum Flow
8 l/s pers.0,55 l/s m 2
5 l/s pers.0,28 l/s m 2
Filtration ODA 1Pure outdoor air F7 F5
Filtration ODA 2 Outdoor air with high particle concentrations or contaminant
F5 + F7 F5 + F6
Filtration ODA 3Outdoor air with high particle concentrations or contaminant
F5 + F7 F5 + F6
Δ
Supply air fan
Compressors
Outdoor fan
Return air fan
0 50 000 100 000 150 000
0
10
20
30
40
2 3 4 6
Multiscroll
Inverter
Number of compressors
[DER] Dynamic Energy Recovery. A subcooler
in the DX circuit increases the unit's output by
15% without any additional compressors.
[AER] Active energy recovery using a separate
DX circuit to recover heat, suitable for exhaust
rates between 20 and 60% of airflow.
[AERH] Enhanced Active energy recovery
using a separate DX circuit to recover heat,
suitable for exhaust rates between 60 and
100% of airflow.
[AER+] Active Energy Recovery + Digital
Scroll: this is Active energy recovery by
a compressor group with Digital Scroll
technology and EC fan.
[ERH] Free Cooling using a two or three way
mixing box, with dampers and automatic
controls to use the outside air for free
cooling.
[ACS] Partial condensation energy recovery.
Includes a de-superheater that allows using
recovered heat for sanitary hot water.
[MSC] Multiscroll refrigerant circuit. Available
option for series 2000 and 3000, with
refrigerant circuit with two compressors in
tandem, increases seasonal energy efficiency
Free cooling & heat recovery options
Annual energy consumption kWh
Typical annual energy consumption for a commercial application
Seasonal efficiency comparison
Assembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
Packaged Air Conditioning Unit
1919
External coils integrated in unit body
3-way mixing box for free-cooling and active recovery.
Controls and electronic components
Sound insulated scroll compressors in closed and insulated compartment.
Low speed axial fans
.......................................................
....................................................... settings
filters G4
F-class filtration
air quality
double F-class filtration
dirty filter indication
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
free cooling thermal/enthalpy
total/partial recovery of con-densation heat
polyurethane coating
copper-copper battery
ALUCOAT fins - CrMg alloy
Blygold coating
anti-corrosion
CO2 sensor duct/ambient
VOC sensor duct/ambient
smoke detector
condensing pressure control
supply/return EC plug fan
external axial EC fans
Axitop diffuser
ventilation
external condensate tray
installation
hot water battery backup
electrical resistance heating 2-phase
antivibration supplement
antifreeze electrical resistances for low temperatures
Carel controls
RS485 communication
control
PGD remote display
master-slave management
Plant Visor / Watch PRO
Energy meter
BACnet / LonWorks communication
included as standard
stainless steel internal condensate tray
optionally available
settings
filters G4
F-class filtration
air quality
double F-class filtration
dirty filter indication
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
free cooling thermal/enthalpy
total/partial recovery of con-densation heat
polyurethane coating
copper-copper battery
ALUCOAT fins - CrMg alloy
Blygold coating
anti-corrosion
CO2 sensor duct/ambient
VOC sensor duct/ambient
smoke detector
condensing pressure control
supply/return EC plug fan
external axial EC fans
Axitop diffuser
ventilation
external condensate tray
installation
hot water battery backup
electrical resistance heating 2-phase
antivibration supplement
antifreeze electrical resistances for low temperatures
Carel controls
RS485 communication
control
PGD remote display
master-slave management
Plant Visor / Watch PRO
Energy meter
BACnet / LonWorks communication
included as standard
stainless steel internal condensate tray
optionally available
settings
filters G4
F-class filtration
air quality
double F-class filtration
dirty filter indication
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
free cooling thermal/enthalpy
total/partial recovery of con-densation heat
polyurethane coating
copper-copper battery
ALUCOAT fins - CrMg alloy
Blygold coating
anti-corrosion
CO2 sensor duct/ambient
VOC sensor duct/ambient
smoke detector
condensing pressure control
supply/return EC plug fan
external axial EC fans
Axitop diffuser
ventilation
external condensate tray
installation
hot water battery backup
electrical resistance heating 2-phase
antivibration supplement
antifreeze electrical resistances for low temperatures
Carel controls
RS485 communication
control
PGD remote display
master-slave management
Plant Visor / Watch PRO
Energy meter
BACnet / LonWorks communication
included as standard
stainless steel internal condensate tray
optionally available
Assembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
Supply
Return
settings
filters G4
F-class filtration
air quality
double F-class filtration
dirty filter indication
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
free cooling thermal/enthalpy
total/partial recovery of con-densation heat
polyurethane coating
copper-copper battery
ALUCOAT fins - CrMg alloy
Blygold coating
anti-corrosion
CO2 sensor duct/ambient
VOC sensor duct/ambient
smoke detector
condensing pressure control
supply/return EC plug fan
external axial EC fans
Axitop diffuser
ventilation
external condensate tray
installation
hot water battery backup
electrical resistance heating 2-phase
antivibration supplement
antifreeze electrical resistances for low temperatures
Carel controls
RS485 communication
control
PGD remote display
master-slave management
Plant Visor / Watch PRO
Energy meter
BACnet / LonWorks communication
included as standard
stainless steel internal condensate tray
optionally available
settings
filters G4
F-class filtration
air quality
double F-class filtration
dirty filter indication
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
free cooling thermal/enthalpy
total/partial recovery of con-densation heat
polyurethane coating
copper-copper battery
ALUCOAT fins - CrMg alloy
Blygold coating
anti-corrosion
CO2 sensor duct/ambient
VOC sensor duct/ambient
smoke detector
condensing pressure control
supply/return EC plug fan
external axial EC fans
Axitop diffuser
ventilation
external condensate tray
installation
hot water battery backup
electrical resistance heating 2-phase
antivibration supplement
antifreeze electrical resistances for low temperatures
Carel controls
RS485 communication
control
PGD remote display
master-slave management
Plant Visor / Watch PRO
Energy meter
BACnet / LonWorks communication
included as standard
stainless steel internal condensate tray
optionally available
Assembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
Assembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
Assembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
Assembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
Assembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
Assembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
Assembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
Assembly TypeAssembly type:
Impulsión
B - Lower
S - Lateral
T - Upper
A - Short side (only with radial ventilat.)
Retorno
B - Lower
S - Lateral
T - Upper
A - Short side
Assembly type
0 - Standard A - Two ways mixing box
B - Axial return C - Centrifugal return
D - Dynamic Recovery E - Axial extraction
F - active recovery with P - Rotary exchanger return fan
R - Active recovery T - External air intake
Z - Radial return EC
0 - Standard B - Axial returnA - Two ways mixing box
0 A B
C - Centrifugal return E - Axial extraction
regnahcxe yratoR - Pnaf nruter htiw yrevocer evitcA - F
Z - Radial return ECT - External air intake
C E
F P
T Z
B
B
B
B
B
S
S
B
A A
TT
S
B
N
BB
SA A
TT
SA
E
B
A
T
S
B
N
S
AS
B
N
E
E
B
A
T
S
B
N
E
B
A
T
S
B
N
E
B
A
T
S
B
N
N
BB
A
T
S E
N
BB
SA A
TT
S
Fresh air
Exhaust air
Adjustable gate
Overpressure gate
N
E
S
AS
B
N
E
FS
Supply air
Return air
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water battery backup
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMANAGER (Carel)
communication RS485
control
command PGD
master-slave management
supervision Plant Visor / Watch P
supervision tERA
energy meter
communication BACNET/LONWOR
stainless steel internal condensate tray
Filtration F
Double Filtration F
Clogged Filter detector
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
freecooling thermal/enthalpy
total/partial recovery of con-densation heat
Polyurethane coating
copper-copper battery
ALUCOAST fin - CrMg alloy
Blygold coating
anti-corrosion
CO2 probe ambient/conduit
VOC probe ambient/conduit
Smoke Detector
supply/return plug-fan EC
external axial fans EC
Axitop diffuser
external condensate tray
installation
hot water
electrical resistance heating (2 phases)
antivibration supplement
antifreeze electrical resistances for low temperatures
platform CLIMAN
communication RS485
control
command PGD
maste
supe
supe
energy meter
communication B
stainless steel internal condensate tray
settings
filters G4
F-class filtration
air quality
double F-class filtration
dirty filter indication
electronic expansion valve
active energy recovery
energy
enhanced active recovery
active energy recovery + digital scroll
free cooling thermal/enthalpy
total/partial recovery of con-densation heat
polyurethane coating
copper-copper battery
ALUCOAT fins - CrMg alloy
Blygold coating
anti-corrosion
CO2 sensor duct/ambient
VOC sensor duct/ambient
smoke detector
condensing pressure control
supply/return EC plug fan
external axial EC fans
Axitop diffuser
ventilation
external condensate tray
installation
hot water battery backup
electrical resistance heating 2-phase
antivibration supplement
antifreeze electrical resistances for low temperatures
Carel controls
RS485 communication
control
PGD remote display
master-slave management
Plant Visor / Watch PRO
Energy meter
BACnet / LonWorks communication
included as standard
stainless steel internal condensate tray
optionally available
Assembly Codes:
Packaged Air Conditioning Unit
.......................................................
.......................................................
Technical Data
Model 0017 0020 0022 0026 0030 0035 1039 1044
Cooling OnlyCooling CapacityNominal absorbed powerEER
kWkW
17.84.93.6
20.75.83.6
23.16.43.6
25.87.03.7
30.58.53.6
34.29.33.7
41.312.53.3
46.213.33.5
Heat PumpHeat CapacityNominal absorbed power coolingEERNominal absorbed power heatingCOP
kWkW
kW
17.85.33.64.94.1
20.76.23.65.54.2
32.16.43.66.939
25.87.73.77.14.1
30.59.23.68.44.1
34.211.13.710.84.0
40.612.93.111.73.5
4613.93.313.83.4
Airflow (m3/h)Supply 3300 3700 4000 4600 5100 6000 6800 7400
Outdoor 9000 9500 14000 14000 14000 20000 20000 20000
No.compressors /no. circuits 1/1 1/1 1/1 1/1 1/1 1/1 1/1 1/1
Stages 1 1 1 1 1 1 1 1
Weight Kg 489 495 504 521 538 561 641 660
Sound pressure level @10m dB(A) 48 49 49 52 55 57 57 58
Technical Data
Model 1041 1045 2050 2060 3070 3080 4090 4095 4100
Cooling OnlyCooling CapacityNominal absorbed powerEER
kWkW
42.512.23.5
47.113.43.5
52.616.83.1
66.418.513.6
74.320.83.6
80.823.43.5
95.527.63.5
95.327.43.5
105.831.23.4
Heat PumpHeat CapacityNominal absorbed power coolingEERNominal absorbed power heatingCOP
kWkW
kW
41.613.23.212.93.3
45.914.63.114.83.2
52.217.63.015.03.5
60.119.53.117.93.5
71.322.23.220.63.6
77.125.23.123.03.5
91.429.231
27.03.4
90.429.53.128.93.2
99.832.43.131.03.3
Airflow (m3/h)Supply 6800 7400 8900 10300 12000 13300 15400 15400 17700
Outdoor 20000 20000 25000 24000 26000 26000 36000 36000 36000
No.compressors /no. circuits 2/1 2/1 2/2 2/2 2/2 2/2 2/2 4/2 4/2
Stages 2 2 2 2 2 2 2 4 4
Weight Kg 682 694 948 1075 1155 1210 1256 1419 1560
Sound pressure level @10m dB(A) 56 57 57 57 58 57 58 58 60
Technical Data
Model 5120 5135 5140 5150 5170 6200 6230
Cooling OnlyCooling CapacityNominal absorbed powerEER
kWkW
123.635.43.5
144.041.73.5
149.843.83.4
159.845.83.5
182.157.53.2
208.963.63.3
230.576.53.0
Heat PumpHeat CapacityNominal absorbed power coolingEERNominal absorbed power heatingCOP
kWkW
kW
118.940.23.037.83.1
134.045.13.040.83.5
144.448.93.043.73.4
155.149.53.146.43.4
173.460.02.953.43.4
200.665.33.163.73.3
218.778.72.881.72.9
Airflow (m3/h)Supply 19800 22700 23500 24900 28600 31900 36000
Outdoor 56000 56000 56000 56000 76000 76000 76000
No.compressors /no. circuits 4/2 4/2 4/2 4/2 4/2 4/2 4/2
Stages 4 4 4 4 4 4 4
Weight Kg 2024 2093 2223 2140 2285 2579 2646
Sound pressure level @10m dB(A) 61 62 62 61 61 64 65
Packaged Air Conditioning Unit.......................................................
.......................................................
1 seires0 seires
series 2-4
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
A
H
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
A
H
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
H
A
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
H
A
series 5-7
Dimensions standard units (mm)
Series 0 Series 1 Series 2 Series 3 Series 4 Series 5 Series 6 Series 7
L 2400 2755 2755 2755 3055 4575 5175 6350
A 1370 2100 2100 2100 2100 2100 2100 2100
H 1430 1175 1555 1810 1810 2200 2490 2200
Dimensions unit upper drawer (set upSC & SF) (mm)
Series 0 Series 1 Series 2 Series 3 Series 4 Series 5 Series 6 Series 7
L 2400 2755 2755 2755 3055 4575 5175 6350
A 1370 2100 2100 2100 2100 2100 2100 2100
H 2050 1830 2230 2490 2490 2490 2490 2490
* Key CR equipment can be manufactured in split version on request.
1 seires0 seires
series 2-4
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
A
H
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
A
H
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
H
A
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
H
A
series 5-7
Dimensions standard units (mm)
Series 0 Series 1 Series 2 Series 3 Series 4 Series 5 Series 6 Series 7
L 2400 2755 2755 2755 3055 4575 5175 6350
A 1370 2100 2100 2100 2100 2100 2100 2100
H 1430 1175 1555 1810 1810 2200 2490 2200
Dimensions unit upper drawer (set upSC & SF) (mm)
Series 0 Series 1 Series 2 Series 3 Series 4 Series 5 Series 6 Series 7
L 2400 2755 2755 2755 3055 4575 5175 6350
A 1370 2100 2100 2100 2100 2100 2100 2100
H 2050 1830 2230 2490 2490 2490 2490 2490
* Key CR equipment can be manufactured in split version on request.
Dimensions (mm)
Model Series 0 Series 1 Series 2 Series 3 Series 4 Series 5 Series 6 Series 7
L 2400 2755 2755 2755 3055 4575 5175 6350
A 1370 2100 2100 2100 2100 2100 2100 2100
H 1430 1175 1555 1810 1810 2200 2490 2200
Dimensions (mm) with Centrifugal Return Air Fan Section
Model Series 0 Series 1 Series 2 Series 3 Series 4 Series 5 Series 6 Series 7
L 2400 2755 2755 2755 3055 4575 5175 6350
A 1370 2100 2100 2100 2100 2100 2100 2100
H 2050 1830 2230 2490 2490 2490 2490 2490
Series 0 Series 1
Series 2-4 Series 5-7
1 seires0 seires
series 2-4
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
A
H
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
A
H
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
H
A
L
RETORNO Y AIRE NUEVO
IMPULSIÓN
H
A
series 5-7
Dimensions standard units (mm)
Series 0 Series 1 Series 2 Series 3 Series 4 Series 5 Series 6 Series 7
L 2400 2755 2755 2755 3055 4575 5175 6350
A 1370 2100 2100 2100 2100 2100 2100 2100
H 1430 1175 1555 1810 1810 2200 2490 2200
Dimensions unit upper drawer (set upSC & SF) (mm)
Series 0 Series 1 Series 2 Series 3 Series 4 Series 5 Series 6 Series 7
L 2400 2755 2755 2755 3055 4575 5175 6350
A 1370 2100 2100 2100 2100 2100 2100 2100
H 2050 1830 2230 2490 2490 2490 2490 2490
* Key CR equipment can be manufactured in split version on request.
Supply
Return
Supply
Return
Supply
Return
Supply
Return
Packaged Air Conditioning Unit......................................................
......................................................
Reznor RTU Selection Procedure
Customer details .............................................................................................................................................................
Project reference ................................................................................................................ Date...................................
Options
Air filter class ..............................
Unit control Built in digital controllerBuilt in digital controller
with BACnetRemote relay interface control
External communication protocol Lon Bacnet Modbus
Air quality CO2 With Without
AXITOP - Acoustic attenuation system With Without
Electronic expansion valve With Without
Smoke detector With Without
Dirty filter switch With Without
Coil coatings Polyurethane coating int Polyurethane coating ext
Heaters for drain pan With Without
Unit anti vibration mounts With Without
Heating mode design conditions
Heating capacity .............................. kW
Auxiliary heat type (if applicable) Electric heat Gas heat LPHW
Gas type (if applicable) Natural gas G20 Natural gas G25 Propane
Indoor air dry bulb .............................. °C
Outdoor air dry bulb .............................. °C
Outdoor air wet bulb / relative humidity .............................. °C .............................. %
Cooling mode design conditions
Unit total cooling capacity .............................. kW
Unit sensible cooling capacity .............................. kW
Indoor air dry bulb .............................. °C
Indoor air wet bulb / relative humidity .............................. °C .................. %
Outdoor air dry bulb .............................. °C
Airflow information
Supply airflow .............................. m3/s or m3/h
Fresh airflow / air rate .............................. m3/s or m3/h
Recirculation airflow / air rate .............................. m3/s or m3/h
External static pressure on return duct .............................. Pa
External static pressure on supply duct .............................. Pa
Please photocopy page and send through any enquiries to [email protected]
Application Type:
Cooling Only HP: Heating and cooling
Cooling and Gas Fired Dual: HP and Gas Fired
Version
Standard
Free cooling
Recovery
Mounting Position
Floor
Roof
NORTEK GLOBAL HVAC (UK) LTD Fens Pool Avenue
Brierley Hill West Midlands DY5 1QA
United Kingdom
Tel: +44 (0)1384 489 250 Fax: +44 (0)1384 489 707
www.reznor.euNortek Global HVAC is a registered trademark of Nortek Global HVAC Limited. Because of continuous product innovation, Nortek Global HVAC reserves the right to change product specification without due notice.
Registered in England No. 01390934 | Registered Office The Colmore Building, Colmore Circus Queensway Birmingham B4 6A
Other products in the Reznor range:-
• Warm air heaters• Radiant heating• Destratification fans• Air curtains• Heating & ventilation units• Air induction systems• Gas fired heater modules• Evaporative cooling
GB/
REZ/
RTU
/016
/012
0