c 2020 1Architecture, LLC
1Architecture, LLC
1319 E. 6th St.
Tulsa, OK 74120
PH. 918.764.9996
ARCHITECT:C
:\U
sers
\gra
ce
.sm
ith
\Docu
me
nts
\200
5-0
14 T
row
er
Add
itio
n_g
race.s
mith
.rvt
TROWER RESIDENCEALTERATION PERMIT SET 08.21.20
PERMIT SET
1716 W CAMERON STTULSA, OK 74127
SHEET TITLE:
ISSUE:
DATE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DRAWN FOR:
1Architecture, LLC
1319 E. 6th St.
Tulsa, OK 74120
PH. 918.764.9996
C:\
Use
rs\
gra
ce
.sm
ith
\D
oc
um
en
ts\
20
05
-01
4 T
row
er
Ad
dit
ion
_g
rac
e.s
mit
h.r
vt
SITE PLAN
2005-014
A100
ALTERATION PERMIT SET
08.21.20
PERMIT SET
GS
ML
1716 W CAMERON ST
TULSA, OK 74127
TROWER RESIDENCE
SITE PLAN1
1
1
SITE PLAN NOTES:
• EXISTING FOOTPRINT OF BUILDING NOT INCREASING.
• ALL NEW WORK TO FALL WITHIN THE EXISTING BUILDING FOOTPRINT
AND THE EXISTING BUILDING HEIGHT.
NO. REVISION DATE
1 REVISION 01 11.19.20
ALL EXISTING WALLS, CEILINGS, AND
FLOORING ON FIRST FLOOR TO
REMAIN. EXISTING OPENINGS NOT
SHOWN
EXISTING BASEMENT STAIRS BELOW
NEW STAIR FROM FIRST FLOOR TO SECOND
FLOOR. FOOTPRINT TO MATCH EXISTING
BASEMENT STAIR. RE: STAIR NOTES
NEW CASED OPENING. RE: DEMO NOTES
EQ
3'
- 0
"
17
' -
1"
A200
4
A2003
A200
2
A200 1
28
' -
11
"
38' - 3" 12' - 1"
50' - 4"
SITE PLAN MAP:
NORTH
GENERAL NOTES:
1. SCALE. DO NOT SCALE DRAWINGS.
2. CODES. CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIAL, AND
LABOR NECESSARY TO SATISFY A COMPLETE AND WORKING SYSTEM WHETHER
SPECIFIED OR IMPLIED. ALL WORK SHALL COMPLY WITH ALL APPLICABLE
NATIONAL, STATE AND LOCAL BUILDING CODES. IT IS THE RESPONSIBILITY OF
THE CONTRACTOR TO INSURE COMPLIANCE WITH SAID CODES.
3. DIMENSIONS. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO
CONSTRUCTION.
4. INSTALLATION. ALL MATERIALS, SUPPLIES AND EQUIPMENT SHALL BE
INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND PER APPLICABLE
CODES AND REQUIREMENTS. THE ARCHITECT SHALL NOT HAVE CONTROL OR
CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES IN CONNECTION WITH
THE WORK, FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUB-
CONTRACTOR, OR ANY OTHER PERSON PERFORMING ANY OF THE WORK, OR
FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS.
5. MATERIAL STORAGE. MATERIALS STORED ON SITE SHALL BE PROTECTED
FROM DAMAGE BY MOISTURE, WIND, SUN, ABUSE, THEFT OR ANY OTHER
HARMFUL AFFECTS.
6. SAFETY. THE CONTRACTOR IS RESPONSIBLE FOR ALL SAFETY PRECAUTIONS
OR SAFETY PROGRAMS USED TO PROVIDE A SAFE WORKING ENVIRONMENT
ON THE JOB SITE. THE CONTRACTOR IS RESPONSIBLE FOR ALL STRUCTURAL
SHORING AND BRACING DURING ALL PHASES OF CONSTRUCTION.
7. PERMITS. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE
RESPONSIBLE TO OBTAIN ALL REQUIRED PERMITS AND APPROVALS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL INSPECTIONS. NO
CONSTRUCTION OR FABRICATION SHALL BEGIN UNTIL THE CONTRACTOR HAS
RECEIVED AND THOROUGHLY REVIEWED ALL PLANS AND OTHER DOCUMENTS
APPROVED BY ALL THE PERMITTING AUTHORITIES. PRIOR TO CONSTRUCTION,
CONTRACTOR TO VERIFY SERVICE WITH ALL UTILITY AGENCIES AND SCHEDULE
ON-SITE INSPECTIONS TO LOCATE ALL UTILITIES.
8. CONTRACT DOCUMENTS. THESE CONTRACT DOCUMENTS ARE THE
PROPERTY OF THE ARCHITECT AND SHALL NOT BE USED WITHOUT HIS OR HER
WRITTEN CONSENT. THESE CONTRACT DOCUMENTS ARE FOR USE SOLELY WITH
RESPECT TO THIS PROJECT. THE OWNER SHALL NOT REUSE OR PERMIT THE
REUSE OF THESE CONTRACT DOCUMENTS EXCEPT BY MUTUAL AGREEMENT IN
WRITING.
MECHANICAL/ELECTRICAL/PLUMBING NOTES:
1. DESIGN/BUILD. MEP SYSTEMS ARE TO BE PROVIDED AS DESIGN-BUILD
COORDINATING DIRECTLY WITH OWNER. MEP CONTRACTOR'S TO PROVIDE
ANY REQUIRED SHOP DRAWINGS FOR REVIEW AND APPROVAL BY OWNER
PRIOR TO START OF WORK. ANY LOCATIONS FOR THE ELEMENTS WITHIN THIS
DRAWING SET ARE SCHEMATIC AND APPROXIMATE IN NATURE, VERIFY FINAL
LOCATIONS WITH OWNER.
2. CODES. CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIAL, AND
LABOR NECESSARY TO SATISFY A COMPLETE AND WORKING SYSTEM WEATHER
SPECIFIED OR IMPLIED. ALL WORK SHALL BE PERFORMED IN ACCORDANCE
WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES GOVERNING
WORK OF THIS NATURE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
INSURE COMPLIANCE WITH SAID CODES.
PROJECT NOTES:
1. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY
ESCAPE AND RESCUE OPENING, PER IRC SECTION R310.1.1-4.
2. SMOKE ALARMS SHALL BE PROVIDED IN SLEEPING ROOMS AND OUTSIDE
EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, PER
IRC SECTION R313.
3. UNLESS NOTED OTHERWISE, STAIR RISE TO BE 7" AND STAIR RUN TO BE 11".
4. UNDER-FLOOR SPACE SHALL HAVE VENTILATION OPENINGS, 1SF FOR EACH
150SF OF UNDER-FLOOR SPACE AREA, PER IRC SECTION R408.
DEMO NOTES:
• REMOVE EXISTING WOOD FRAMED GYPSUM WALLS TO ALLOW FOR NEW
FRAMING AND DOORS.
• REMOVE EXISTING WOOD FRAMED GYPSUM WALLS TO ALLOW FOR NEW
STAIRS AND FRAMING.
STAIR NOTES:
• MAX RISE - 7 3/4"
• MIN RUN - 10"
• MIN HEAD CLEARANCE - 6'-8"
• UNDER STAIR PROTECTION - ENCLOSE ACCESSIBLE CLOSET SPACE W/ 1/2"
GYPSUM BOARD.
• HANDRAILS ON BOTH SIDES OF STAIR, TOP OF RAIL MUST BE 34-38" ABOVE
THE STAIR NOSING. HANDRAIL GRIPS MUST BE 1 1/4" MIN - 2 5/8" MAX IN
OUTSIDE DIAMETER AND MUST BE CONTINUOUS FROM A POINT DIRECTLY
ABOVE THE TOP RISER TO A POINT DIRECTLY ABOVE THE LOWEST RISER OF
THE FLIGHT. ENDS SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS.
HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN
1 1/2" BETWEEN THE WALL AND THE HANDRAIL.
• GUARDS - OPENING LIMITATIONS - REQUIRED GUARDS ON OPEN SIDES OF
STAIRWAYS, RAISED FLOOR AREAS, BALCONIES AND PORCHES SHALL HAVE
INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES THAT DO NOT ALLOW
PASSAGE OF A 4" SPHERE.
WINDOW NOTES:
• FINAL WINDOW SIZES TO BE DETERMINED BY OWNER AND APPLICABLE
CODE REQUIREMENTS. CONTRACTOR TO VERIFY THAT WINDOW ALLOWS
FOR EMERGENCY ESCAPE - MIN. REQUIRED OPENING AREA OF 5.7 SF 24"
MIN HEIGHT AND 20" MIN WIDTH. RE: PROJECT NOTES.
PLAN NOTES:
• EXISTING FOOTPRINT OF BUILDING NOT INCREASING.
• ALL NEW WORK TO FALL WITHIN THE EXISTING BUILDING FOOTPRINT AND THE
EXISTING BUILDING HEIGHT.
SHEET TITLE:
ISSUE:
DATE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DRAWN FOR:
1Architecture, LLC
1319 E. 6th St.
Tulsa, OK 74120
PH. 918.764.9996
C:\
Use
rs\
gra
ce
.sm
ith
\D
oc
um
en
ts\
20
05
-01
4 T
row
er
Ad
dit
ion
_g
rac
e.s
mit
h.r
vt
DEMO FIRST FLOOR
PLAN & REFERENCE
ELEVATION
2005-014
A101
ALTERATION PERMIT SET
08.21.20
PERMIT SET
GS
ML
1716 W CAMERON ST
TULSA, OK 74127
TROWER RESIDENCE
TRUENORTH
PROJECTNORTH
3/8" = 1'-0"
DEMO PLAN - EXISTING FIRST FLOOR1
NO. REVISION DATE
311 SF
SITTING ROOM
303 SF
BEDROOM
148 SF
BATH
21 SF
TOILET
BALCONY
COFFEE BAR/TV STATION
NEW WINDOW.RE: WINDOW & PROJECT NOTES
SHELV
ES
HIGH MIDDLE WINDOW. RE: WINDOW & PROJECT NOTES
EXISTING ROOF BELOWTO REMAIN
LOW ROOF
LOW ROOF
MATCHES WIDTHOF BASEMENT STAIRS
OPTIONAL USE
EXISTING PLUMBING(APPROX.)
CHASE
108 SF
CUBBY
118 SF
CLOSET
4' - 6 1/2" 6' - 0" 17' - 2"
15' - 9" 6' - 11" 9' - 11"
7' - 10 1/2" 11' - 2 1/2" 11' - 2"
4' - 6 1/2"
11
' -
1"
17
' -
0"
13' - 4" 3' - 6"6'
- 6
"
CANTILEVERED BALCONY AND GUARD RAIL (MIN 42")RE: STRUCTURAL AND STAIR NOTES
ABOVE TO REMAIN
EXTENT OF EXISTING ROOF & RIDGE BEAM
EXTENT OF EXISTING RIDGE BEAM ABOVE TO BE REMOVED AND REPLACED. NEW RIDGE HEIGHT TO MATCH EXISTING ADJACENT. RE: STRUCTURAL
EXTENT OF EXISTING ROOF ABOVE TO BE REMOVED AND REPLACED WITH NEW SLOPE.
NEW DOOR3'-0" X 6'-8", TYP
NEW DOOR3'-0" X 6'-8", TYP
NEW DOOR3'-0" X 6'-8", TYP
A200
4
A2003
A200
2
A200 1
NEW WINDOW, TYP RE: WINDOW & PROJECT NOTES
6"
6"
6" 6"
1'
- 0
"
1' - 0"
WALKLINE SHOWN DASHED
10
3/8
"
PROVIDE REQUIRED CARBON MONOXIDE ALARM IN ACCORDANCE WITH R315
10 3/8" 10 3/8"
10
3/8
"
SITE PLAN MAP:
NORTH
GENERAL NOTES:
1. SCALE. DO NOT SCALE DRAWINGS.
2. CODES. CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIAL, AND
LABOR NECESSARY TO SATISFY A COMPLETE AND WORKING SYSTEM WHETHER
SPECIFIED OR IMPLIED. ALL WORK SHALL COMPLY WITH ALL APPLICABLE
NATIONAL, STATE AND LOCAL BUILDING CODES. IT IS THE RESPONSIBILITY OF
THE CONTRACTOR TO INSURE COMPLIANCE WITH SAID CODES.
3. DIMENSIONS. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO
CONSTRUCTION.
4. INSTALLATION. ALL MATERIALS, SUPPLIES AND EQUIPMENT SHALL BE
INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND PER APPLICABLE
CODES AND REQUIREMENTS. THE ARCHITECT SHALL NOT HAVE CONTROL OR
CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES IN CONNECTION WITH
THE WORK, FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUB-
CONTRACTOR, OR ANY OTHER PERSON PERFORMING ANY OF THE WORK, OR
FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS.
5. MATERIAL STORAGE. MATERIALS STORED ON SITE SHALL BE PROTECTED
FROM DAMAGE BY MOISTURE, WIND, SUN, ABUSE, THEFT OR ANY OTHER
HARMFUL AFFECTS.
6. SAFETY. THE CONTRACTOR IS RESPONSIBLE FOR ALL SAFETY PRECAUTIONS
OR SAFETY PROGRAMS USED TO PROVIDE A SAFE WORKING ENVIRONMENT
ON THE JOB SITE. THE CONTRACTOR IS RESPONSIBLE FOR ALL STRUCTURAL
SHORING AND BRACING DURING ALL PHASES OF CONSTRUCTION.
7. PERMITS. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE
RESPONSIBLE TO OBTAIN ALL REQUIRED PERMITS AND APPROVALS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL INSPECTIONS. NO
CONSTRUCTION OR FABRICATION SHALL BEGIN UNTIL THE CONTRACTOR HAS
RECEIVED AND THOROUGHLY REVIEWED ALL PLANS AND OTHER DOCUMENTS
APPROVED BY ALL THE PERMITTING AUTHORITIES. PRIOR TO CONSTRUCTION,
CONTRACTOR TO VERIFY SERVICE WITH ALL UTILITY AGENCIES AND SCHEDULE
ON-SITE INSPECTIONS TO LOCATE ALL UTILITIES.
8. CONTRACT DOCUMENTS. THESE CONTRACT DOCUMENTS ARE THE
PROPERTY OF THE ARCHITECT AND SHALL NOT BE USED WITHOUT HIS OR HER
WRITTEN CONSENT. THESE CONTRACT DOCUMENTS ARE FOR USE SOLELY WITH
RESPECT TO THIS PROJECT. THE OWNER SHALL NOT REUSE OR PERMIT THE
REUSE OF THESE CONTRACT DOCUMENTS EXCEPT BY MUTUAL AGREEMENT IN
WRITING.
MECHANICAL/ELECTRICAL/PLUMBING NOTES:
1. DESIGN/BUILD. MEP SYSTEMS ARE TO BE PROVIDED AS DESIGN-BUILD
COORDINATING DIRECTLY WITH OWNER. MEP CONTRACTOR'S TO PROVIDE
ANY REQUIRED SHOP DRAWINGS FOR REVIEW AND APPROVAL BY OWNER
PRIOR TO START OF WORK. ANY LOCATIONS FOR THE ELEMENTS WITHIN THIS
DRAWING SET ARE SCHEMATIC AND APPROXIMATE IN NATURE, VERIFY FINAL
LOCATIONS WITH OWNER.
2. CODES. CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIAL, AND
LABOR NECESSARY TO SATISFY A COMPLETE AND WORKING SYSTEM WEATHER
SPECIFIED OR IMPLIED. ALL WORK SHALL BE PERFORMED IN ACCORDANCE
WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES GOVERNING
WORK OF THIS NATURE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
INSURE COMPLIANCE WITH SAID CODES.
PROJECT NOTES:
1. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY
ESCAPE AND RESCUE OPENING, PER IRC SECTION R310.1.1-4.
2. SMOKE ALARMS SHALL BE PROVIDED IN SLEEPING ROOMS AND OUTSIDE
EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, PER
IRC SECTION R313.
3. UNLESS NOTED OTHERWISE, STAIR RISE TO BE 7" AND STAIR RUN TO BE 11".
4. UNDER-FLOOR SPACE SHALL HAVE VENTILATION OPENINGS, 1SF FOR EACH
150SF OF UNDER-FLOOR SPACE AREA, PER IRC SECTION R408.
DEMO NOTES:
• REMOVE EXISTING WOOD FRAMED GYPSUM WALLS TO ALLOW FOR NEW
FRAMING AND DOORS.
• REMOVE EXISTING WOOD FRAMED GYPSUM WALLS TO ALLOW FOR NEW
STAIRS AND FRAMING.
STAIR NOTES:
• MAX RISE - 7 3/4"
• MIN RUN - 10"
• MIN HEAD CLEARANCE - 6'-8"
• UNDER STAIR PROTECTION - ENCLOSE ACCESSIBLE CLOSET SPACE W/ 1/2"
GYPSUM BOARD.
• HANDRAILS ON BOTH SIDES OF STAIR, TOP OF RAIL MUST BE 34-38" ABOVE
THE STAIR NOSING. HANDRAIL GRIPS MUST BE 1 1/4" MIN - 2 5/8" MAX IN
OUTSIDE DIAMETER AND MUST BE CONTINUOUS FROM A POINT DIRECTLY
ABOVE THE TOP RISER TO A POINT DIRECTLY ABOVE THE LOWEST RISER OF
THE FLIGHT. ENDS SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS.
HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN
1 1/2" BETWEEN THE WALL AND THE HANDRAIL.
• GUARDS - OPENING LIMITATIONS - REQUIRED GUARDS ON OPEN SIDES OF
STAIRWAYS, RAISED FLOOR AREAS, BALCONIES AND PORCHES SHALL HAVE
INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES THAT DO NOT ALLOW
PASSAGE OF A 4" SPHERE.
WINDOW NOTES:
• FINAL WINDOW SIZES TO BE DETERMINED BY OWNER AND APPLICABLE
CODE REQUIREMENTS. CONTRACTOR TO VERIFY THAT WINDOW ALLOWS
FOR EMERGENCY ESCAPE - MIN. REQUIRED OPENING AREA OF 5.7 SF 24"
MIN HEIGHT AND 20" MIN WIDTH. RE: PROJECT NOTES.
PLAN NOTES:
• EXISTING FOOTPRINT OF BUILDING NOT INCREASING.
• ALL NEW WORK TO FALL WITHIN THE EXISTING BUILDING FOOTPRINT AND THE
EXISTING BUILDING HEIGHT.
SHEET TITLE:
ISSUE:
DATE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DRAWN FOR:
1Architecture, LLC
1319 E. 6th St.
Tulsa, OK 74120
PH. 918.764.9996
C:\
Use
rs\
gra
ce
.sm
ith
\D
oc
um
en
ts\
20
05
-01
4 T
row
er
Ad
dit
ion
_g
rac
e.s
mit
h.r
vt
SECOND FLOOR PLAN
2005-014
A102
ALTERATION PERMIT SET
08.21.20
PERMIT SET
GS
ML
1716 W CAMERON ST
TULSA, OK 74127
TROWER RESIDENCE
3/8" = 1'-0"
SECOND FLOOR PLAN1 TRUENORTH
PROJECTNORTH
1
1
1
1
NO. REVISION DATE
1 REVISION 01 11.19.20
NEW ROOF. RIDGE HEIGHT TO
MATCH EXISTING ADJACENT.
RE: STRUCTURAL
NEW CANTILEVERED BALCONY
AND GUARD RAIL (MIN 42")
RE: STRUCTURAL AND STAIR NOTES
NEW EXTERIOR WALL AND SIDING.
MATCH EXISTING ADJACENT
NEW WINDOW, TYP.
RE: WINDOW & PROJECT NOTES EXISTING ROOF AND RIDGE HEIGHT
NEW ROOF. RIDGE HEIGHT TO
MATCH EXISTING ADJACENT.
RE: STRUCTURAL
NEW EXTERIOR WALL AND SIDING.
MATCH EXISTING ADJACENT
NEW ROOF. RIDGE HEIGHT TO
MATCH EXISTING ADJACENT.
RE: STRUCTURAL
NEW CANTILEVERED BALCONY
AND GUARD RAIL (MIN 42")
RE: STRUCTURAL AND STAIR NOTES
NEW EXTERIOR WALL AND SIDING.
MATCH EXISTING ADJACENT
NEW WINDOW, TYP.
RE: WINDOW & PROJECT NOTES
NEW ROOF. RIDGE HEIGHT TO
MATCH EXISTING ADJACENT.
RE: STRUCTURAL
NEW CANTILEVERED BALCONY
AND GUARD RAIL (MIN 42")
RE: STRUCTURAL AND STAIR NOTES
NEW EXTERIOR WALL AND SIDING.
MATCH EXISTING ADJACENT
NEW WINDOW, TYP.
RE: WINDOW & PROJECT NOTES
SITE PLAN MAP:
NORTH
SHEET TITLE:
ISSUE:
DATE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DRAWN FOR:
1Architecture, LLC
1319 E. 6th St.
Tulsa, OK 74120
PH. 918.764.9996
C:\
Use
rs\
gra
ce
.sm
ith
\D
oc
um
en
ts\
20
05
-01
4 T
row
er
Ad
dit
ion
_g
rac
e.s
mit
h.r
vt
EXTERIOR ELEVATIONS
2005-014
A200
ALTERATION PERMIT SET
08.21.20
PERMIT SET
GS
ML
1716 W CAMERON ST
TULSA, OK 74127
TROWER RESIDENCE
1/4" = 1'-0"
WEST ELEVATION2 1/4" = 1'-0"
NORTH ELEVATION1
1/4" = 1'-0"
EAST ELEVATION4 1/4" = 1'-0"
SOUTH ELEVATION3
NO. REVISION DATE
DIVISION 2 - WOOD FRAMING
1. ALL WOOD PLATES BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED LUMBER.2. ALL METAL CONNECTORS SHALL MEET THE FOLLOWING:
A. CLIPS AND FASTENERS SHALL BE CORROSION RESISTANT.B. RATED TO PROVIDE LOAD RESISTANCE EQUAL TO CLIP SHOWN ON THE PLANS.C. APPROVED BY I.C.C. AND OTHER REQUIRED LOCAL CODE AGENCIES.D. INSTALLED AS RECOMMENDED BY THEIR MANUFACTURER.
3. ALL WOOD TRUSSES OR JOIST AND RAFTERS SHALL BE FASTENED TO TOP PLATE WITH ONE (1) SIMPSON H3 AND ONE (1) SIMPSON A34 METAL CLIP OR APPROVED EQUAL, UNO.
4. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR FASTENING OF HANGERS IN ORDER TO ACHIEVE THE REQUIRED ALLOWABLE LOADS SHOWN ON THE PLANS. WHERE REQUIRED ALLOWABLE LOADS ARE NOT SHOWN, USE THE MAXIMUM RATED STRENGTH OF THE HANGER.
5. WHEN CONNECTORS ARE NOT SHOWN, TABLE 2304.10.1 FASTENING SCHEDULE OF THE INTERNATIONAL BUILDING CODE SHALL APPLY.6. WHEN HEADERS ARE NOT SHOWN, TABLE 2308.4.1 HEADER DESIGN CHART OF THE INTERNATIONAL BUILDING CODE SHALL APPLY.7. PROVIDE SUPPLEMENTAL STRUCTURAL FRAMING AND BLOCKING AS REQUIRED TO ACHIEVE SOLID AND SOUND STRUCTURAL AND NON-STRUCTURAL
ELEMENTS USING ACCEPTED FRAMING PRACTICES.8. MINIMUM WOOD FRAMING MATERIAL SPECIFICATIONS ARE AS FOLLOWS:
A. FRAMING 2-4 INCHES THICK, 2 INCHES AND WIDER, DOUGLAS FIR SOUTH #21. Fb = 850 PSI (SINGLE MEMBER USE)2. Ft = 525 PSI3. Fc = 1350 PSI (PARALLEL TO GRAIN)4. Fc = 520 PSI (PERPENDICULAR TO GRAIN)5. Fv = 180 PSI6. E = 1,200,000 PSI
DIVISION 3 - WOOD ROOF SHEATHING
1. ALL ROOF SHEATHING SHALL BE PLACED IN SUCH A MANNER TO STAGGER ALL END JOINTS OF PANELS AND WITH LONG DIRECTION PERPENDICULARTO SUPPORTS. ALUMINUM PANEL CLIPS SHALL BE PLACED AT MID-SPAN OF PANELS BETWEEN EACH TRUSS AS DECKING IS BEING LAID. INSTALLER SHALL LEAVE 1/8" SPACE AT ALL PANEL EDGES AND END JOINTS, UNLESS OTHERWISE RECOMMENDED BY MANUFACTURER.
2. FASTENING REQUIREMENTS FOR DECKING TO SUPPORTS SHALL BE IN COMPLIANCE WITH THE AMERICAN PLYWOOD ASSOCIATION'S (APA) RECOMMENDED MINIMUM FASTENING SCHEDULE FOR APA PANEL ROOF (OR WALL) SHEATHING AS STATED HEREIN. SEE ROOF FRAMING PLAN (S-201) FOR ROOF SHEATHING FASTENING REQUIREMENTS. CLIPS AND FASTENERS SHALL BE CORROSION RESISTANT.
3. COVER SHEATHING AS SOON AS POSSIBLE WITH ROOFING FELT FOR PROTECTION AGAINST EXCESSIVE MOISTURE PRIOR TO ROOFING APPLICATION.PROTECTION MATERIAL MUST BE APPROVED BY I.C.C. AND FOLLOW OTHER REQUIRED LOCAL CODE AGENCIES.
4. UNLESS NOTED OTHERWISE, PLYWOOD STRUCTURAL PANELS NOTED ON THE DRAWINGS SHALL CONFORM TO U.S. DEPARTMENT OF COMMERCE VOLUNTARY PRODUCT STANDARDS, PS 1, STRUCTURAL PLYWOOD (DOC PS 1), OR PS 2, PERFORMANCE STANDARD FOR WOOD-BASED STRUCTURAL-USE PANELS (DOC PS 2), AND TO BE IDENTIFIED BY THE MARK OF AN APPROVED TESTING AND GRADING AGENCY.
DESIGN PARAMETERS
1. BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE
2. DEAD LOADS:A. ROOF-------------------------------------------------------------------------------------------------- 15 PSFB. FLOOR-------------------------------------------------------------------------------------------------- 15 PSF
3. LIVE LOADS:A. ROOF-------------------------------------------------------------------------------------------------- 20 PSF (UNIFORM)B. FLOOR-------------------------------------------------------------------------------------------------- 40 PSF (UNIFORM)
4. SNOW LOADS:A. GROUND SNOW LOAD, Pg---------------------------------------------------------------------- 10 PSF
5. WIND LOADS:A. BASIC WIND SPEED (3 SECOND GUST)---------------------------------------------------- 115 MPHB. RISK CATEGORY----------------------------------------------------------------------------------- IIC. EXPOSURE CLASSIFICATION------------------------------------------------------------------ BD. INTERNAL PRESSURE COEFFICIENT------------------------------------------------------- ± 0.18E. BASIC WIND PRESSURE (qh,UNFACTORED)--------------------------------------------- 17.4 PSFF. DESIGN WIND PRESSURE ON EXTERIOR WALLS (C&C LOAD BASED ON 100 SQ.FT AREA)
• END ZONES, (a=3'-0")------------------------------------------------------------------------22.2 PSF• INTERIOR ZONES--------------------------------------------------------------------------- 24.7 PSF
G. DESIGN UPLIFT PRESSURE ON ROOFS (C&C LOAD BASED ON 100 SQ.FT AREA)• CORNER ZONES, (a=3'-0")------------------------------------------------------------------44.0 PSF• EDGE ZONES, (a=3'-0")----------------------------------------------------------------------27.8 PSF• INTERIOR ZONES---------------------------------------------------------------------------- 19.8 PSF
6. SEISMIC LOADS:A. SPECTRAL RESPONSE ACCELERATION; (SHORT PERIOD), Ss---------------------0.131B. SPECTRAL RESPONSE ACCELERATION; (1-SEC. PERIOD), S1---------------------0.068C. SPECTRAL RESPONSE COEFFICIENT; (SHORT PERIOD), Sds----------------------0.139D. SPECTRAL RESPONSE COEFFICIENT; (1-SEC. PERIOD), Sd1---------------------- 0.110E. SITE CLASS------------------------------------------------------------------------------------------- DF. IMPORTANCE FACTOR, I ------------------------------------------------------------------------ 1.0G. SEISMIC DESIGN CATEGORY ----------------------------------------------------------------- BH. BASIC STRUCTURAL SYSTEM AND SEISMIC RESISTING SYSTEM-------------- LIGHT FRAME (WOOD) WALLS SHEATHED WITH WOOD STRUCTURAL
PANELS RATED FOR SEISMIC RESISTANCE. I. RESPONSE MODIFICATION FACTOR, R -------------------------------------------------- 6.5J. SYSTEM OVER-STRENGTH FACTOR, W -------------------------------------------------- 3K. DEFLECTION AMPLIFICATION FACTOR, Cd --------------------------------------------- 4L. ANALYSIS PROCEDURE --------------------------------------------------------------------------EQUIVALENT LATERAL FORCE
GENERAL
1. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACTDOCUMENTS INTO THE SHOP DRAWINGS AND FIELD WORK.
2. WHERE CONFLICT EXISTS AMONG VARIOUS PARTS OF THE STRUCTURAL CONTRACT DOCUMENTS, STRUCTURAL DRAWINGS, GENERAL NOTES, AND SPECIFICATIONS, THE STRICTEST REQUIREMENTS, AS INDICATED BY THE ENGINEER, SHALL GOVERN.
3. WHERE MEMBER LOCATIONS ARE NOT SPECIFICALLY DIMENSIONED, THE FOLLOWING RULES SHALL APPLY:A. COLUMNS ARE CENTERED ON GRID LINES.B. FOOTINGS ARE CENTERED BENEATH COLUMNS.C. CONTINUOUS FOOTINGS ARE CENTERED BENEATH WALLS.D. FRAMING MEMBERS ARE EITHER LOCATED ON GRID LINES OR ARE EQUALLY SPACED BETWEEN LOCATED MEMBERS.
4. ALL STRUCTURAL ELEMENTS OF THE PROJECT HAVE BEEN DESIGNED BY THE STRUCTURAL ENGINEER TO RESIST THE REQUIRED CODE VERTICAL ANDLATERAL FORCES THAT COULD OCCUR IN THE FINAL COMPLETED STRUCTURE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL REQUIRED BRACING DURING CONSTRUCTION TO MAINTAIN THE STABILITY AND SAFETY OF ALL STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PROCESS UNTIL THE LATERAL LOAD RESISTING OR STABILITY-PROVIDING SYSTEM IS COMPLETELY INSTALLED AND THE STRUCTURE IS COMPLETELY TIED TOGETHER.
5. THE STRUCTURE HAS BEEN DESIGNED FOR THE LOADS IDENTIFIED WITHIN THESE STRUCTURAL DRAWINGS THAT ARE ANTICIPATED TO BE APPLIED TO THE FINAL STRUCTURE ONCE COMPLETED AND OCCUPIED. THE CONTRACTOR SHALL NOT OVERLOAD THE STRUCTURE DURING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING THE ADEQUACY OF THE STRUCTURE TO SUPPORT ANY APPLIED CONSTRUCTION LOADS, INCLUDING THOSE DUE TO CONSTRUCTION VEHICLES OR EQUIPMENT, MATERIAL HANDLING OR STORAGE, SHORING AND RESHORING, OR ANY OTHER PROPOSED CONSTRUCTION LOADS THAT ARE IN EXCESS OF THE STATED DESIGN LOADS. THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE TO DESIGN OR CHECK THE STRUCTURE FOR LOADS APPLIED TO THE STRUCTURE FOR ANY CONSTRUCTION ACTIVITY.
6. WEIGHTS OF MECHANICAL EQUIPMENT SHOWN ON THE STRUCTURAL PLANS ARE FOR UNITS SPECIFIED BY THE MECHANICAL ENGINEER. CONTRACTOR SHALL VERIFY THE WEIGHTS. ANY SUBSTITUTIONS THAT RESULT IN INCREASED WEIGHT SHALL BE APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.
7. THE SIZE AND LOCATION OF EQUIPMENT PADS AND PENETRATIONS THROUGH THE STRUCTURE FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK SHALL BE VERIFIED BY THE CONTRACTOR. OPENINGS AND PENETRATIONS NOT SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE SUBJECT TO APPROVAL BY THE STRUCTURAL ENGINEER OF RECORD.
8. PRIOR TO FABRICATION AND/OR ERECTION OF ANY MATERIALS, THE CONTRACTOR SHALL FIELD VERIFY ALL PERTINENT EXISTING DIMENSIONS, ELEVATIONS, AND CONDITIONS AND SHALL REPORT ANY DISCREPANCIES TO THE STRUCTURAL ENGINEER OF RECORD OR THE ARCHITECT IMMEDIATELY UPON DISCOVERY.
9. BACKFILL BOTH SIDES OF ALL FOUNDATION AND RETAINING WALLS EQUALLY UNTIL LOW SIDE IS UP TO FINISH GRADE. DO NOT BACKFILL ANY WALLS UNTIL CONCRETE HAS REACHED ITS SPECIFIED 28-DAY COMPRESSIVE STRENGTH.
10. CONNECTIONS OF SYSTEMS DESIGNED BY THE CONTRACTOR’S ENGINEER SUCH AS, BUT NOT LIMITED TO, CLADDING, STAIRS, ELEVATORS AND MEP LOADS ARE ASSUMED TO IMPOSE VERTICAL AND/OR HORIZONTAL LOADS ON THE BASE BUILDING STRUCTURAL MEMBERS WITHOUT GENERATING TORSION IN THE SUPPORTING STRUCTURAL MEMBERS. CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING ALL SUPPLEMENTARY BRACING MEMBERS AS REQUIRED TO PREVENT TORSION ON THE BASE BUILDING STRUCTURE.
11. ANY MATERIALS OR PRODUCTS SUBMITTED FOR APPROVAL THAT ARE DIFFERENT FROM THE MATERIAL OR PRODUCTS SPECIFIED IN THE STRUCTURALCONTRACT DOCUMENTS WILL BE APPROVED ONLY IF THE FOLLOWING CRITERIA ARE SATISFIED:
A. A COST SAVINGS TO THE OWNER IS DOCUMENTED AND SUBMITTED WITH THE REQUEST.B. THE MATERIAL OR PRODUCT HAS BEEN APPROVED BY THE INTERNATIONAL CODE COUNCIL (ICC) AND THE ICC REPORT IS SUBMITTED WITH
THE REQUEST.12. THE ENGINEER SHALL NOT HAVE CONTROL NOR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES, OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, FOR THE ACTS OR OMISSION OF THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
13. PERIODIC SITE OBSERVATION BY FIELD REPRESENTATIVES OF 360 ENGINEERING GROUP, PLLC. IS SOLELY FOR THE PURPOSE OF BECOMING GENERALLY FAMILIAR WITH THE PROGRESS AND QUALITY OF THE WORK COMPLETED AND DETERMINING, IN GENERAL, IF THE WORK OBSERVED IS BEING PERFORMED IN A MANNER INDICATING THAT THE WORK, WHEN FULLY COMPLETED, WILL BE IN ACCORDANCE WITH THE STRUCTURAL CONTRACT DOCUMENTS. THIS LIMITED SITE OBSERVATION SHOULD NOT BE CONSTRUED AS AN EXHAUSTIVE OR CONTINUOUS CHECK OF THE QUALITY OR QUANTITY OF THE WORK, BUT RATHER PERIODIC IN AN EFFORT TO GUARD THE OWNER AGAINST DEFECTS OR DEFICIENCIES IN THE WORK OF THE CONTRACTOR.
Certificate of Authorization:
OK #5996 | EXP 6.30.2022
36
0 E
ng
ine
eri
ng
Gro
up
, P
LLC
www.360enggroup.com
12
01
Ea
st 3
rd S
tre
et
Tu
lsa
, O
K 7
41
20
91
8.5
18
.11
24
SHEET TITLE:
ISSUE:
DATE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DRAWN FOR:
1Architecture, LLC
1319 E. 6th St.
Tulsa, OK 74120
PH. 918.764.9996
E:\
Sh
are
d\
36
0 P
LLC
Pu
blic
\Jo
bfile
s\O
ne
Arc
hite
ctu
re\
20
28
9_1
71
6 W
Ca
me
ron
St\
02
_D
wg
s\0
1_R
vt\
20
28
9_1
716
W C
am
ero
n S
t_STR
_V
19
7.2
2.r
vt
GENERAL NOTES
20289
S001
Cameron St. Roof
Addition
08.04.2020
PERMIT DOCUMENTS
AM
AL
1716 W. CAMERON ST.
TULSA, OK 74127
NO. REVISION DATE
SEFORP
DE
SE
CIL
A
RE
ENI
GN
E
LAN
OIS
MOHALKO
LANDRUM
AARON
25535
N
08/04/2020
2x12
AT
16"
OC
BA
LCO
NY
6' - 0" 4' - 0"
(2)- 2x12 (2)- 2x12
(2)- 2x12 (2)- 2x12
(2)
-2x1
2
2x12 AT 16" OC
2x12 AT 16" OC
2x12 AT 16" OC
(2)-2x12
6
S501
6
S501
5
S501
S501
7
(2)-
2x12
-C
EN
TE
R U
ND
ER
ST
UD
GA
NG
(2)-
2x12
-C
EN
TE
R U
ND
ER
ST
UD
GA
NG
2x12 AT 16" OC 2x12 AT 16" OC
(2)-
2x12
-C
EN
TE
R U
ND
ER
ST
UD
GA
NG
(4)-
2x12
-C
EN
TE
R U
ND
ER
ST
UD
GA
NG
2x12 AT 16" OC
2x12 AT 16" OC
Certificate of Authorization:
OK #5996 | EXP 6.30.2022
36
0 E
ng
ine
eri
ng
Gro
up
, P
LLC
www.360enggroup.com
12
01
Ea
st 3
rd S
tre
et
Tu
lsa
, O
K 7
41
20
91
8.5
18
.11
24
SHEET TITLE:
ISSUE:
DATE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DRAWN FOR:
1Architecture, LLC
1319 E. 6th St.
Tulsa, OK 74120
PH. 918.764.9996
E:\
Sh
are
d\
36
0 P
LLC
Pu
blic
\Jo
bfile
s\O
ne
Arc
hite
ctu
re\
20
28
9_1
71
6 W
Ca
me
ron
St\
02
_D
wg
s\0
1_R
vt\
20
28
9_1
716
W C
am
ero
n S
t_STR
_V
19
7.2
2.r
vt
FLOOR FRAMING PLAN
20289
S101
Cameron St. Roof
Addition
08.04.2020
PERMIT DOCUMENTS
AM
AL
1716 W. CAMERON ST.
TULSA, OK 74127
FLOOR FRAMING PLAN NOTES
1. SEE SHEET S001 FOR GENERAL NOTES.
2. SEE ARCHITECTURAL PLANS FOR DIMENSIONS NOT SHOWN.
3. SEE MECHANICAL AND ARCHITECTURAL DRAWINGS FOR SIZES AND LOCATION OF PENETRATIONS NOT INDICATED ON STRUCTURAL DRAWINGS.
4. ALL FLOOR FRAMING MEMBERS TO BEAR ON TOP OF EXISTING COLUMNS/WALLS TYP, UNO.
5. ALL FLOOR SHEATHING SHALL BE TONGUE AND GROOVE APA RATED EXPOSURE 1 SHEATHING WITH A MINIMUM THICKNESS OF 23/32", DOC PS-1 OR PS-2, WITH ASPAN RATING OF AT LEAST 48/24 GLUED AND SCREWED WITH #10 WOOD SCREWS AT 6" OC AT PANEL EDGES AND AT 12" OC AT INTERM
7. NEW STUD WALLS SHOWN TO BE 2X6 EXTERIOR AND 2X4 INTERIOR AT 16" OC DOUGLAS FIR SOUTH NO. 2, UNO. SEE ARCH FOR STUD WALL LOCATIONS.
3/8" = 1'-0"1FLOOR FRAMING PLAN
NO. REVISION DATE
INDICATES STUD GANG LOCATION WITH NUMBER OF STUDSREQUIRED. PROVIDE 2 STUDS MINIMUM UNLESS NOTEDOTHERWISE. STUD GANG SHALL BE CONTINUOUS THROUGHDEPTH OF FLOOR USING MATCHING BLOCKING FROM HIGHESTBEAM ELEVATION TO FOUNDATION
-
SEFORP
DE
SE
CIL
A
RE
ENI
GN
E
LAN
OIS
MOHALKO
LANDRUM
AARON
25535
N
08/04/2020
4' - 7 1/2" 6' - 0" 17' - 2" 4' - 0"
11
' - 4
"
10
' - 8
"
17
' - 5
"
15' - 11" 6' - 11" 9' - 11"
7' - 11 1/2" 11' - 3 1/2" 11' - 2"
4' - 7 1/2"
11
' - 1
"1
7' -
0"
13' - 4" 3' - 6"6' -
6"
CL CLCL CLCL
2x10 AT 16" O.C
2x10 AT 16" OC
5
S501
EXTENT OF EXISTING ROOF PER ARCH'L EXTENT OF EXISTING ROOF TO BE REMOVED AND REPLACED WITH NEW SLOPE PER ARCH'L
(2)- 2x10 (2)- 2x10 2x10
2x10
2x10
ALIGN WITH EXSTING WALL BELOW
INDICATES STUD GANG LOCATION WITH NUMBER OF STUDSREQUIRED. PROVIDE 2 STUDS MINIMUM UNLESS NOTEDOTHERWISE. STUD GANG SHALL BE CONTINUOUS THROUGHDEPTH OF FLOOR USING MATCHING BLOCKING FROM HIGHESTBEAM ELEVATION TO FOUNDATION
-
Certificate of Authorization:
OK #5996 | EXP 6.30.2022
36
0 E
ng
ine
eri
ng
Gro
up
, P
LLC
www.360enggroup.com
12
01
Ea
st 3
rd S
tre
et
Tu
lsa
, O
K 7
41
20
91
8.5
18
.11
24
SHEET TITLE:
ISSUE:
DATE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DRAWN FOR:
1Architecture, LLC
1319 E. 6th St.
Tulsa, OK 74120
PH. 918.764.9996
E:\
Sh
are
d\
36
0 P
LLC
Pu
blic
\Jo
bfile
s\O
ne
Arc
hite
ctu
re\
20
28
9_1
71
6 W
Ca
me
ron
St\
02
_D
wg
s\0
1_R
vt\
20
28
9_1
716
W C
am
ero
n S
t_STR
_V
19
7.2
2.r
vt
ROOF FRAMING PLAN
20289
S102
Cameron St. Roof
Addition
08.04.2020
PERMIT DOCUMENTS
AM
AL
1716 W. CAMERON ST.
TULSA, OK 74127
ROOF FRAMING PLAN NOTES
1. SEE SHEET S001 FOR GENERAL NOTES.
2. SEE ARCHITECTURAL PLANS FOR DIMENSIONS NOT SHOWN.
3. SEE MECHANICAL AND ARCHITECTURAL DRAWINGS FOR SIZES AND LOCATION OF PENETRATIONS NOT INDICATED ON STRUCTURAL DRAWINGS.
4. ALL FRAMING MEMBERS TO BEAR ON TOP OF COLUMNS/WALLS TYP, UNO.
5. INTSALL SIMPSONH2.5A CLIP AT ALL RAFTER BEARING LOCATIONS.
6. ALL ROOF SHEATHING SHALL BE APA RATED EXPOSURE 1 SHEATHING WITH A MINIMUM THICKNESS OF 19/32", DOC PS-1 OR PS-2, WITH A SPAN RATING OF ATLEAST 32/16 NAILED WITH 8d GALVANIZED COMMON NAILS AT 6" OC AT PANEL EDGES AND AT 12" OC AT INTERMEDIATE SUPPORTS TYP
3/8" = 1'-0"1ROOF FRAMING PLAN
NO. REVISION DATE
SEFORP
DE
SE
CIL
A
RE
ENI
GN
E
LAN
OIS
MOHALKO
LANDRUM
AARON
25535
N
08/04/2020
SPLICES CTR JT ON STUD
4' - 0" MIN LAP BETWEEN
MID
HE
IGH
T
BLO
CK
IN
HORIZ BLOCKINGUSED AS FIRESTOP
FIN FLR
SEE PLAN
TREATED SILLOR SOLE PLATE
INTERMEDIATE ANCHORAGE, SEE FOUNDATION DETAILS
NAIL SPLICE W/ MIN (6) 16d EASIDE OF JT IN TOP OR BOT PLATE
DBL 2x TOP PLATE
STUDS
1/8" GAP (TYP ALL EDGES)
SPAN
DIRECTION FACE GRAINPERPENDICULAR TO SUPPORT
ROOF TRUSSES/JOISTS AT 24" OC
GALV STEEL 'H' CLIPSALONG PANEL BOUNDARY
DISCONTINUOUS PANEL EDGE
FIELD NAILING
UNBLOCKEDDIAPHRAGM
1. STAGGER JOINTS AS SHOWN2. MIN SIZE OF SHEET SHALL BE 24"x24"3. NAIL EA CORNER OF PANEL & MID-POINT OF FULL SIZE SHEETS PRIOR TO NAILING4. NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF SHEATHING5. TOLERANCE ON FASTENING SHALL BE +/- 1" WITH THE AVERAGE NAIL SPACING OVER ANY 48" LENGTH BEING AT LEAST THAT NOTED ON THE PLAN6. SEE DETAIL FOR BLOCK DETAILS AT RIDGES7. SEE WOOD ROOF SHEATHING NOTES ON THE GENERAL NOTES SHEET AND THE PLAN NOTES
ROOF SHEATHING NOTES
FULL HEIGHT KING STUD
ROOF FRAMING AT 24" OC
(2) 2x WOOD PLATEFOR ROOF FRAMING
2x HEADER, SEE SCHEDFOR SIZE
BUILT-UP JAMB, SEE SCHEDULE
TREATED BOT PLATE
INTERMEDIATE ANCHORAGESEE FOUNDATION DETAILS.
FIN FLR
SEE PLAN
SEE ARCH DWGSFOR OPENINGDIMENSIONS
FULL HEIGHT KING STUD
SEE ARCH FOR WINDOW SIZES
ANCHORAGE: SEE SHEARWALL SCHEDULE
MARK MAX SPAN HEADER JACK STUD KING STUD
H1 UP TO 5'-0" (3)-2x10 (1)-2x (3)-2x
• SEE PLAN FOR HEADER ASSIGNMENT AT OPENINGS
BRNG EL
SEE ARCH
F/STUD
2x FASCIA BOARD
EXT GRADE SHEATHING
B/EAVE EL
SEE ARCH. 2x STUDS (SEE PLAN NOTES)
ROOF RAFTERS (SEE PLAN)
E/ROOF
SEE PLAN ROOF SHEATHING PER PLAN
DOUBLE TOP PLATE
UPLIFT TIE (SEE PLAN NOTES)
S501
6
S501
7
ROOF FRAMING PER PLAN
FLOOR JOISTS PER PLAN STAGGERED WITH EXISTING JOISTS PER DETAIL 7/S501
EXISTING FRAMING - TYP
WALL FRAMING PER PLAN
S501
6
S501
8
S501
8
DOUBLE SILL PLATE - TYP
T.O.
SILL PLATE
T.O.
RIDGE
FIE
LD V
ER
IFY
3' -
0"
8'-0
" M
AX
OVERFRAMING BY OTHERS
WALL FRAMING PER PLAN
EXISTING JOIST BEYOND
EXISTING SILL
EXISTING WALL FRAMING
SILL PLATE PER TYP. DETAIL
FLOOR DECK - SEE PLAN
EXISTING JOIST
FLOOR FRAMING PER PLAN
2X BLOCKING BETWEEN FLOOR JOISTS - TYP
EXISTING SILL PLATE AT INTERIOR BEARING WALL
3/4" PLYWOOD MIN
UPPER LANDING
LOWER LANDING
FLOOR JOISTS
(3)-1-3/4"x14" LVL HEADER AT TOP OF STAIR STRINGER. USE FACE MOUNT HANGER AT STRINGER
WOOD STRINGERS PER SCHEDULE
2x WOOD CLEAT AT FLOOR
VA
RIE
S TREAD
11"
MA
X R
ISE
R
7"
UN
CU
T D
EPTH
3/4" = 1'-0"1TYP BEARING STUD WALL ELEV
3/4" = 1'-0"3ROOF SHEATHING ON FRAMING
Certificate of Authorization:
OK #5996 | EXP 6.30.2022
36
0 E
ng
ine
eri
ng
Gro
up
, P
LLC
www.360enggroup.com
12
01
Ea
st 3
rd S
tre
et
Tu
lsa
, O
K 7
41
20
91
8.5
18
.11
24
SHEET TITLE:
ISSUE:
DATE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DRAWN FOR:
1Architecture, LLC
1319 E. 6th St.
Tulsa, OK 74120
PH. 918.764.9996
E:\
Sh
are
d\
36
0 P
LLC
Pu
blic
\Jo
bfile
s\O
ne
Arc
hite
ctu
re\
20
28
9_1
71
6 W
Ca
me
ron
St\
02
_D
wg
s\0
1_R
vt\
20
28
9_1
716
W C
am
ero
n S
t_STR
_V
19
7.2
2.r
vt
WOOD FRAMING
DETAILS
20289
S501
Cameron St. Roof
Addition
08.04.2020
PERMIT DOCUMENTS
AM
AL
1716 W. CAMERON ST.
TULSA, OK 74127
3/4" = 1'-0"2EXTERIOR LINTEL ELEV AT BEARING WALL
3/4" = 1'-0"8PERIMETER WALL DETAIL - RAFTER
1/2" = 1'-0"5TYPICAL SECTION
1" = 1'-0"6FRAMING ON EXISTING EXTERIOR WALL
1 1/2" = 1'-0"7PLAN VIEW - NEW AND EXISTING FRAMING
3/4" = 1'-0"4WOOD STAIRS
WOOD STAIR STRINGER SCHEDULE
MAX SPANSTRINGER SIZE AND
SPACINGMINIMUM UNCUT
DEPTH
5' MAX 2x12 AT 12" OC 5 1/4"
10' MAX 1 3/4"x11 1/4" LVL AT 12" OC 5 1/4"
15' MAX 1 3/4"x14" LVL AT 12" OC 8"
NO. REVISION DATE
SEFORP
DE
SE
CIL
A
RE
ENI
GN
E
LAN
OIS
MOHALKO
LANDRUM
AARON
25535
N
08/04/2020