Rochdale Holdings Pty Ltd A.B.N. 85 009 049 067 trading as:
HERRING STORER ACOUSTICS Suite 34, 11 Preston Street, Como, W.A. 6152 P.O. Box 219, Como, W.A. 6952 Telephone: (08) 9367 6200 Facsimile: (08) 9474 2579 Email: [email protected]
TOTAL GREEN RECYCLING
40 FELSPAR STREET, WELSHPOOL
2017 BOUNDARY NOISE SURVEY
JUNE 2017
OUR REFERENCE: 21850‐1‐17119
Herring Storer Acoustics
DOCUMENT CONTROL PAGE
FELSPAR STREET, WELSHPOOL
2017 BOUNDARY SURVEY
Job No: 17119
Document Reference: 21850‐1‐17119
FOR
TOTAL GREEN RECYCLING
DOCUMENT INFORMATION
Author: Paul Daly Checked by: Tim Reynolds
Date of Issue: 9 June 2017
REVISION HISTORY
Revision Description Date Author Checked
DOCUMENT DISTRIBUTION
Copy No. Version No. Destination Hard Copy Electronic Copy
1 1 Total Green Recycling Email [email protected]
Herring Storer Acoustics
CONTENTS
1. INTRODUCTION 1
2. METHODOLOGY 1
3. RESULTS 1
4. ASSESSMENT 2
5. DISCUSSION / RECOMMENDATIONS 2
APPENDICIES A Boundary Noise Levels B Boundary 1/3 Octave Band Data Figure 1
Herring Storer Acoustics Our ref: 21850‐1‐17119
1
1. INTRODUCTION Herring Storer Acoustics (HSA) was commissioned by Total Green Recycling to undertake a boundary noise survey of their facility located at 40 Felspar Street, Welshpool.
The objective of this study was to carry out noise level measurements around the boundary of the facility and compare to the regulatory criteria.
2. METHODOLOGY Noise level measurements were performed around the boundary of the facility on Thursday 1 June 2017 using a Svan 948 Precision Sound Level Meter. Measurement locations are shown in Appendix A. Measurements were conducted with the facility operating at full capacity. This involved all internal equipment such as the sorting line, grinder and shredder operating. Externally, operating noise sources included the diesel generator and the extraction fan system. During the measurement period weather conditions were; winds from the west‐north west at around 2 m/s and a temperature of 13°C. Additionally, preliminary noise modelling has been conducted to assess the noise level at the nearest highly noise sensitive premises. The computer program, Soundplan has been used to calculate the noise level of the Total Green Recycling facility. Noise level measurements conducted during the site visit were used as the basis of the noise sources in the predictive modelling software. Receiver locations for the assessment were based on the nearest residence, located at Turtledove Grove in Welshpool (south) and Chervil Bend in Wattle Grove to the east.
3. RESULTS The results of the short‐term hand held measurements and the predicted noise levels are summarised in Table 1.
TABLE 1 – RESULTANT NOISE LEVEL
Location Total Green Recycling Operating
Condition
Measured Noise Level, dB(A)
June 2017 Measured Noise Levels
A Full Operation 58
B Full Operation 58
C Full Operation 64
C Background – All Equipment Off 65
D Fan On ‐ With Air Cleaning Engaged 85
D Fan On ‐ NO Air Cleaning 84
D Fan Off 72
E Full Operation 64
Turtledove Grove, Welshpool Full Operation 21
Chervil Bend, Wattle Grove Full Operation 3
The third octave band data recorded at boundary locations is contained in Appendix B.
Herring Storer Acoustics Our ref: 21850‐1‐17119
2
4. ASSESSMENT
Analysis of this third octave band data shows tonal components in the 50Hz frequency. Observations during the measurements were that this noise emission was attributable to the operating fan system on located on the southern side of the facility (Location D). It is noted that this is a technical exceedance with compliance achieved at around 25m from the fan. The boundary location is situated adjacent to a car park, with the nearest potential office building located 75m to the south east or 115m to the south west. Therefore, it is likely that the noise levels, whilst exceeding the regulatory requirements, are not impacting on the neighbouring premises.
Background noise levels measured during period of no operation at the Total Green Recycling facility showed tonal components at the 160 Hz frequency. These are attributable to other industry not associated with the Total Green facility.
The noise levels associated with the Total Green facility generally comply at boundary premises, with the exception of the southern boundary where the fan system is located.
The assessable noise level for the Total Green Recycling facility noise emissions at the nearest highly sensitive noise receptors are 3 and 21 dB(A). At this level, the noise would comply with the assigned noise level for all hours and is likely to be inaudible.
5. DISCUSSION / RECOMMENDATIONS
The assessable noise level at boundary location D to the south of the Total Green facility exceed the regulatory criteria. The noise levels are attributable to the close proximity to the boundary of the fan system used for air extraction for the internal machinery.
As the fan system is in good operating condition, being relatively new, noise control to the source is unlikely to have a major impact. Therefore, it is recommended that to achieve compliance, it is recommended that a barrier be positioned along the southern fence line between the boundary and the fan. The form of the barrier can be anything solid, such as a sea container or like provided it extends 1m above the outlet of the fan. Alternatively, if the barrier high cannot be achieved, the outlet of the fan can be repositioned to face away from the boundary. Figure 1 below shows the fan system and the proposed barrier location.
FIGURE 1 – FAN SYSTEM AND PROPOSED BARRIER
Proposed Barrier Location
Outlet to be repositioned
APPENDIX A
BOUNDARY NOISE LEVELS
Herring Storer Acoustics Our ref: 21580‐1‐17119 Appendix A
APPENDIX B
THIRD OCTAVE BAND DATA
BOUNDARY
Herring Storer Acoustics Our ref: 21850‐1‐17119 Appendix B
Rochdale Holdings Pty Ltd A.B.N. 85 009 049 067 trading as:
HERRING STORER ACOUSTICS Suite 34, 11 Preston Street, Como, W.A. 6152 P.O. Box 219, Como, W.A. 6952 Telephone: (08) 9367 6200 Facsimile: (08) 9474 2579 Email: [email protected]
EMAIL TRANSMITTAL
REF: 21996‐1‐17119
TO: Total Green Recycling
ATTENTION: James Coghill
ADDRESS: [email protected]
FROM: Paul Daly
DATE: 14 July 2017
SUBJECT: TOTAL GREEN RECYCLING – PROPOSED NEW LOCATION
James, Further to the email received on Thursday 10 July 2017, we provide the following information. It is understood that the Total Green Recycling facility is going to relocate its operations to 26 Miles Road, Kewdale. All equipment currently located at 40 Felspar Street, Welshpool is to be relocated to the new facility. Herring Storer Acoustics have previously conducted an acoustic assessment of the facility in Welshpool, hence have measured noise levels of the equipment proposed for the new site. Whilst a detailed acoustic assessment of the new site will be required as a part of the approval process, it has been requested that a preliminary assessment of the main extraction fan system (dominant external noise source) is carried out, to provide an indication of the suitability at the new facility. The proposed layout at the Miles road facility is as per Figure 1.
FIGURE 1 – PROPOSED NEW FACILITY
Herring Storer Acoustics Our Ref: 21996‐1‐17119 2
Based on the measured noise level at 1 metre from the operating extraction fan ie, 85 dB(A), the predicted noise level at the nearest industrial boundary would be 53 dB(A).
This can be compared to the regulatory criteria of not to exceed 65 dB(A), hence at the new location, the fan noise emissions would be compliant.
If you need more information, please do not hesitate to contact us.
Yours faithfully, for HERRING STORER ACOUSTICS
Paul Daly
Department of Water and Environmental Regulation
Application Form: Works Approval, Licence, Renewal, Amendment or Registration (July 2017 v7)17
IR-F09 v7.0
ATTACHEMENT 6B – Waste Acceptance
Item Description
Desktop Computer
Notebook Computer
Netbook Computer
Tablet Computer
Thin Client
Monitor (LCD/ LED)
Monitor (CRT) less than or equal to 19"
Monitor (CRT) more than 19" diagonal
Computer Peripherals and Electronic Media (including keyboards, mice, external hard drives, webcams, power cables, USB hubs, docking stations, security locks, carry bags, CDs, DVDs, USB memory sticks, others)
Telephone
Mobile Telephone
Switch
Hub
Router
Television (LCD/LED)
Television (Plasma)
Television (CRT)
VCR/ DVD/ CD/ Disk/ Tape drives/ players, Hi-Fi sets, radios
Projector (Data/ Multimedia)
Camera (Digital/ Still/ Digital Video)
Whiteboard (Electronic/ Interactive)
Large Format Display (LCD, LED, Plasma, Touch screen sensitive)
Tower Case Server
Rack Intensive Server
Blade Server
Date Storage Devices
Printer (Inkjet/ Laser)
Scanner
Photocopier
Department of Water and Environmental Regulation
Application Form: Works Approval, Licence, Renewal, Amendment or Registration (July 2017 v7)18
IR-F09 v7.0
Facsimile Machine
Multi-Functional Device
Plotters/ Large Format Printers
Consumables including inkjet and toner cartridges, toner bottles
All ICT batteries except for alkaline batteries e.g. laptop batteries, Uninterruptible power supplies (UPS)
OTHER ICT GOODS
Office Furniture
Fridges and Air conditioners
Derivative commodities of items listed above.
Department of Water and Environmental Regulation
Application Form: Works Approval, Licence, Renewal, Amendment or Registration (July 2017 v7)19
IR-F09 v7.0
ATTACHEMENT 7 – Siting
The proposed premises is 1.02 km to the nearest school, as shown in attachment 2 B
The proposed premises is 1.7km to the nearest sensitive wetlands and the water table is at a depth of 5m below ground as per Perth ground water report, and proximity to wetlands map attached.
Perth Groundwater Map
26 MILES ROAD KEWDALE 6105
Depths
Depth from ground level to:
Water table: 5.0 m
Base of Aquifer: 27.5 m
Levels relative to AHD (~sea level):
Natural Surface: 17.5 m
Water table: 12.5 m
Base of Aquifer: -10.0 m
Depth to Groundwater
5.0 metres
Depth of Water
22.5 metres
Water Quality
Groundwater Salinity: <250
Surface Geology Type: Swamp and lacustrine deposits - peat, peaty sand and clay|Qrw
Iron Staining Risk: Low risk
Garden Bore Suitability: Suitable
Acid Sulfate Class: Moderate to low risk
Public Drinking Water Source Areas (PDWSA):
N/A
2 October 2017 06:11 PM
User Comments:The following comments were entered by the user
Generated from Groundwater Map
Proximity to wetlands
Ramsar WetlandsNationally Important WetlandsWorld Heritage Properties
October 2, 2017
© Commonwealth of Australia (Geoscience Australia) 2014) PSMA Australia Limited 2014
0 1 20.5 mi
0 2 41 km
1:72,224
Map produced by the Department of the Environment.
Department of Water and Environmental Regulation
Application Form: Works Approval, Licence, Renewal, Amendment or Registration (July 2017 v7)20
IR-F09 v7.0
Attachment 9 Proposed Fee – Based on Budget
TRUCKING COSTTruck Items onboard Desitination Vehicle Time for Trip Hrly rate Total
Processing Plant Items1 Primary shredder, Secondary Shredder Raffs, Miles Rd Semi Trailer 2 110 2202 Primary shredder Miles Rd Semi Trailer 2 110 2202 Hammer Mill, Overband Magnet, Eddy Current Seperator with Frame Miles Rd Semi Trailer 2.5 110 2753 Eddy Current seperator Vibrators and Drum Mag, Walk Ways Miles Rd Semi Trailer 2.5 110 2754 Feed Conveyor, picking Conveyor, Steel Conveyors Miles Rd Semi Trailer 1.5 110 1655 Secondary Conveyor, Plastic and Zorba Conveyor, Screens Miles Rd Semi Trailer 1.5 110 1656 Dust Extractor, Genset, Compressor Miles Rd Semi Trailer 2.5 110 2757 Glass Line, Ducting and Rollers. Miles Rd Semi Trailer 2 110 2208 Baler, Hydrualic Power Pack Miles Rd Semi Trailer 2.5 110 2759 Commodity container 1 , 2 x A line Benches, 4 x BC Benches Miles Rd Semi Trailer 1.5 110 165
10 Commodity container 2, Weigh Scales, Weigh in Benches, 3 BC Benches Miles Rd Semi Trailer 1.5 110 16511 Commodity container 3, 10 cages Miles Rd Semi Trailer 1.5 110 16512 Plastic Container 1, Cages and Racking from Stores Miles Rd Semi Trailer 1.5 110 16513 Plastic Container 2, Office Furntiture Miles Rd Semi Trailer 1.5 110 16514 Control Boards Miles Rd 12 Tonner 1.5 68 10215 Miscellaneous Trips Miles Rd 12 Tonner 16 68 1088
Total 4105
Cranage Cost
Processing Plant Items Location Crane Time Required Hrly Rate TotalPrimary shredder, Secondary Shredder Felspar St 25T Franna 2 240 480Hammer Mill, Overband Magnet, Eddy Current Seperator with Frame Felspar St 25T Franna 3 240 720Eddy Current seperator Vibrators and Drum Mag, Walk Ways Felspar St 25T Franna 2 240 480Feed Conveyor, picking Conveyor, Steel Conveyors Felspar St Forklift 0Secondary Conveyor, Plastic and Zorba Conveyor, Screens Felspar St Forklift 0Dust Extractor, Genset, Compressor Felspar St 25T Franna 3 240 720Glass Line, Ducting and Rollers. Felspar St Sideloader 0Baler, Hydrualic Power Pack Felspar St 25T Franna 2.5 240 600Commodity container 1 , 2 x A line Benches, 4 x BC Benches Felspar St 25T Franna 1 240 240Commodity container 2, Weigh Scales, Weigh in Benches, 3 BC Benches Felspar St 25T Franna 1 240 240Commodity container 3, 10 cages Felspar St 25T Franna 1 240 240Plastic Container 1, Cages and Racking from Stores Felspar St 25T Franna, side loader 1 240 240Plastic Container 2, Office Furntiture Felspar St 25T Franna, side loader 1 240 240Primary shredder, Secondary Shredder Miles Rd 25T Franna 2 240 480Hammer Mill, Overband Magnet, Eddy Current Seperator with Frame Miles Rd 25T Franna, Overhead Crane 2 240 480Eddy Current seperator Vibrators and Drum Mag, Walk Ways Miles Rd 25T Franna 1.5 240 360Feed Conveyor, picking Conveyor, Steel Conveyors Miles Rd Forklift 0Secondary Conveyor, Plastic and Zorba Conveyor, Screens Miles Rd Forklift 0Dust Extractor, Genset, Compressor Miles Rd 25T Franna 3.5 240 840Glass Line, Ducting and Rollers. Miles Rd Sideloader 0Baler, Hydrualic Power Pack Miles Rd 25T Franna 3 240 720Commodity container 1 , 2 x A line Benches, 4 x BC Benches Miles Rd 25T Franna 1 240 240Commodity container 2, Weigh Scales, Weigh in Benches, 3 BC Benches Miles Rd 25T Franna 1 240 240Commodity container 3, 10 cages Miles Rd 25T Franna 1 240 240Plastic Container 1, Cages and Racking from Stores Miles Rd 25T Franna 1 240 240Plastic Container 2, Office Furntiture Miles Rd 25T Franna 1 240 240
Total 8280
Electrical
Decommisioning Felspar St Location Equipment Required Time Required hrly Rate TotalGenset Main supply Felspar Ladder 1 80 80
Controll Board 1 (primary) FelsparSupply to board Felspar 1 80 80Primary Shredder Felspar 0.5 80 40Feed Conveyor Felspar 0.5 80 40Steel Line Felspar 0.5 80 40Picking Line Felspar 0.5 80 40Vibrating Screen Felspar 0.5 80 40
Control Board 2 (overband Magnet) FelsparSupply to Board Felspar 1 80 80Overband Magnet Felspar 0.5 80 40
Control Board 3 (secondary) Felspar
Secondary Shredder supply board 1 80 80Secondary shredder Felspar 0.5 80 40Secondary Shredder Feed conveyor Felspar 0.5 80 40
Control Board 4 (Hammer Mill) FelsparSupply to board Felspar 1 80 80Hammer Mill Felspar 0.5 80 40Feed Conveyor Felspar 0.5 80 40Discharge conveyor Felspar 0.5 80 40
Control board 5 (ECS) FelsparSupply to board Felspar EWP 1 80 80Vibrator 1 Felspar 0.5 80 40Vibrator 2 Felspar 0.5 80 40ECS Felspar 0.5 80 40Drum Mag Felspar 0.5 80 40
Control Board 6 (screen and discharge) FelsparSupply to board Felspar 1 80 80Vibrator Felspar 0.5 80 40Plastic Fines Felspar 0.5 80 40Zorba Fines Felspar 0.5 80 40
Dust Extractor board FelsparSupply to board Felspar 1 80 80Fan Felspar 0.5 80 40Pulse System Felspar EWP 0.5 80 40Removal of Cable Felspar EWP 2 80 160
Baler FelsparSupply to board Felspar 1 80 80Removal of Cable Felspar EWP 1 80 80
Glass Line FelsparSupply To Board Felspar 1 80 80Removal of Cable Felspar EWP 1 80 80
Compressor FelsparSupply to board Felspar 1 80 80Removal of Cable Felspar EWP 2 80 160
Total 2160
Recommisioning Miles Rd Location Equipment Required Time RequiredMain Supply Miles Rd Ladder 4 80 320Running Cable to Main Board Miles Rd EWP 4 80 320Terminating Cable to Main Board Miles Rd EWP 2 80 160
Controll Board 1 (primary) Miles RdSupply to board Miles Rd 1 80 80Primary Shredder Miles Rd 0.5 80 40Feed Conveyor Miles Rd 0.5 80 40Steel Line Miles Rd 1 80 80Picking Line Miles Rd 0.5 80 40Vibrating Screen Miles Rd 0.5 80 40
Control Board 2 (overband Magnet) Miles RdSupply to Board Miles Rd 1 80 80Overband Magnet Miles Rd 0.5 80 40
Control Board 3 (secondary) Miles Rd
Secondary Shredder supply board Miles Rd 1 80 80Secondary shredder Miles Rd 0.5 80 40Secondary Shredder Feed Miles Rd 0.5 80 40
Control Board 4 (Hammer Mill) Miles RdSupply to board Miles Rd 1 80 80Hammer Mill Miles Rd 0.5 80 40Feed Conveyor Miles Rd 0.5 80 40Discharge conveyor Miles Rd 0.5 80 40
Control board 5 (ECS) Miles RdSupply to board Miles Rd EWP 1 80 80Vibrator 1 Miles Rd 0.5 80 40Vibrator 2 Miles Rd 0.5 80 40ECS Miles Rd 2 80 160Drum Mag Miles Rd 0.5 80 40
Control Board 6 (screen and discharge) Miles RdSupply to board Miles Rd 2 80 160Vibrator Miles Rd 0.5 80 40Plastic Fines Miles Rd 0.5 80 40Zorba Fines Miles Rd 0.5 80 40
Dust Extractor board Miles Rd EWPSupply to board Miles Rd EWP 2 80 160Fan Miles Rd 1 80 80Pulse System Miles Rd EWP 1 80 80
Baler Miles RdSupply to board Miles Rd 3 80 240Running Cable to Main Board Miles Rd EWP 2 80 160
Glass Line Miles RdSupply To Board Miles Rd 2 80 160Running Cable to Main Board Miles Rd EWP 2 80 160
Compressor Miles RdSupply to board Miles Rd 2 80 160Removal of Cable Miles Rd EWP 2 80 160
Total 3600
Equipment Hire Location Unit Type Qty Unit Cost TotalEWP Felspar & Miles week inclusive of pick up and dro 4 250 1000Forklifts Miles week inclusive of pick up and dro 4 250 1000Total 2000
Electrical Cable/Supplies Location Unit type Qty Unit Cost Total240mm supply Cable Miles Cost/m 200 21 420016mm 4c+E Miles Cost/m 100 9.7 970500A Main switch and Breaker Miles Unit 1 4000 4000Total 9170
Mechanical Location Unit Type QtyCable Tray & Accessories Miles estimate 1 2000 2000Total 2000
Fabrication
Modication and Fabrication Location Unit Type Qty Unit Cost TotalShredder comb repair Raffs Estimate 1 1500 1501300mm spacer Kit Raffs Quoted amount 1 2398 2398Mod on Steel conveyor Raffs Estimate 1 1200 1200Total 5099
Ducting Etc
Dust Extraction Location Unit Type Qty Unit Cost TotalExtra Pieces Miles Estimate to be confirmed 1 1000 1000Roof Plumber Miles Estimate to be confirmed 1 500 500Total 1500
Grand Total 37914