Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
f. 3
TM 11-2200
, WAR DEPARTMENT. A Pi ^^ ^
TECHNICAL MANUAL
METER I-97-A
August, 1943
<yii
7
Genera
ted o
n 2
01
5-1
2-0
3 1
6:5
7 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
-2
TECHNICAL MANUAL f/ 1 ', 9& WAR DEPARTMENTNo. 11-2200 ^juJWashington, 14 August, 1943
^^
BIAS METER I-97-A
This technical manual published on order no. 4656-Phila-43 isfurnished for the information and guidance of all concerned.
TABLE OF CONTENTSSECTION I Description Paragraph
General ............................... 1
Components ........................... 2
Size and Weight ........................ 3
SECTION II Installation and Operation
Installation ........................... 4
Power Supply ......................... 5
Preparation for Use ................... 6
Operating Adjustments ................. 7
SECTION III Functioning of Parts
General Circuit ........................ 8
Normal Operation ..................... 9
Bias Indication ....................... 10
Bias Measuring Circuit .................. 11
Use of Jack ........................... 12
SECTION IV Maintenance
Servicing ............................. 13
Zero Bias Adjustments ................. 14
SECTION V Supplementary Data
List of Maintenance Parts ............... 15
LIST OF ILLUSTRATIONSFig. Page
1 Bias Meter I-97-A................ 3
2 General Circuit of Bias Meter I-97-A ................. 6
3 Equivalent Connections with Pushbutton non-operated. . 8
4 Equivalent Connections for Reading Bias(Pushbutton depressed) ........................ 9
5 Parts Identification I-97-A. .....,...,,.,,...... ....... 11
M558587
Genera
ted o
n 2
01
5-1
2-0
3 1
6:5
7 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
TM 11-2200 SIGNAL CORPS
DESTRUCTION NOTICE
WHY —To prevent the enemy from using or salvaging thisequipment for his benefit.
WHEN —When ordered by your commander, or when you are in
immediate danger of capture.
HOW —1. Smash — Use sledges, axes, hand-axes, pick-axes,hammers, crowbars, heavy tools, etc.
2. Cut — Use axes, hand-axes, machete, etc.
3. Burn — Use gasoline, kerosene, oil, flame-throwers,
incendiary grenades, etc.
4. Explosives — Use firearms, grenades, TNT, etc.
6. Disposal — Bury in slit trenches, fox-holes, otherholes. Throw in streams. Scatter.
6. USE ANYTHING IMMEDIATELY AVAILABLEFOR DESTRUCTION OF THIS EQUIPMENT.
WHAT —1 . Smash—Meter, pushbutton, case, adapter plug, relay
subbase.
2. Cut — Adapter Plug Cable and Power Cord, in sev
eral pieces.
3. Burn — Technical Manuals, Canvas Carrying Case
CS-49-A.
4. Bury or Scatter —All pieces, after destroying them.
DESTROY EVERYTHING
Genera
ted o
n 2
01
5-1
2-0
3 1
6:5
7 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
BIAS METER I-97-A TM 11-2200
1
SECTION I—DESCRIPTION
1. General.
a. Bias Meter I-97-A is for measuring bias in teletypewritersignals and is used in connection with the adjustment of springtension on Western Union 41-C type relays as used in Line UnitBE-77, a component part of Telegraph Printer Sets EE-97 andEE-98. Figure 1 shows an overall view of the bias meter.
Fig. 1. Bias Meter I-97-A
6. Bias is a term denoting a lengthening or shortening oftransmitted teletypewriter signal impulses by the electrical characteristics of the transmission line or the electrical or mechanicalcharacteristics of the transmitter. When these characteristicslengthen each signal, it is said to have marking or positive bias.
When these characteristics reduce the length of each signal, it issaid to have spacing or negative bias. Bias can be largely com-
3
Genera
ted o
n 2
01
5-1
2-0
3 1
6:5
7 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
TM 11-2200 SIGNAL CORPS2-3
pensated for in the receiving apparatus by changing the springtension of the relay. Thus, if a line has marking bias, the springtension of the relay can be increased so its contacts close a littlelater and open a little earlier for each signal, and the length oftime the relay contacts are closed can usually be made the sameas the length of time of a perfect signal.
2. Components.
Bias Meter I-97-A contains the following componentsmounted within a sheet metal case with a hinged cover:
a. A meter for indicating bias.
6. A socket into which the telegraph relay normally con
tained in Line Unit BE-77 can be plugged.
c. An adapter plug connected to the bias meter by a 3-footextension cord. This plug is placed in the relay subbase of LineUnit BE-77 after the telegraph relay has been transferred fromthe line unit to the socket of Bias Meter I-97-A.
d. A pushbutton type key which can be depressed to connect
the meter in circuit to read bias.
e. A power cord and plug for connection to a source of 115
volts direct current.
/. A bias measuring circuit consisting of resistors in a bridgearrangement and a capacitor and inductance for damping the
needle of the bias meter.
g. A 0-400-ohm rheostat, located inside the case of the biasmeter, for adjusting the measuring circuit so that the meter
indicates correctly on a standard teletypewriter signal.
h. A jack into which the output of a teletype test distributorcan be patched for checking the correctness of the rheostat set
ting, or into which any source of neutral teletypewriter signals
may be patched for measuring the bias of such signals.
3. Size and Weight.
Bias Meter I-97-A is 7" x 4i/2" x 4%" high, and weighs
6 pounds.
4
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
4 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
BIAS METER I-97-A TM 11-2200
4-7
SECTION II—INSTALLATION AND OPERATION
4. Installation.
Remove the bias meter from the canvas carrying Case
CS-49-A and install it near Line Unit BE-77, so that the adaptercord of the bias meter will reach the relay subbase in the lineunit and the power cord will reach a source of 115 volts directcurrent.
5. Power Supply.
Bias Meter I-97-A needs a source of 115 volts d-c powerfor its operation. This will normally be the same source of powerused for Line Unit BE-77.
6. Preparation for Use.
a. Connect the power cord of Bias Meter I-97-A to a source
of 115 volts direct current so that the meter needle deflects to theleft when the pushbutton is depressed and no relay or plug is inthe subbase of the bias meter. If the meter needle deflects to theright, withdraw the attachment plug from the power source, turnit 180°, and reinsert it.
6. Remove the Western Union 41-C relay from Line UnitBE-77 and insert the plug of the adapter cord assembly of the
bias meter into the socket from which the relay was removed.
c. Insert the Western Union 41-C relay in the socket of BiasMeter I-97-A.
7. Operating Adjustments.
a. While the operator of the distant station sends "repeatedspace" signals by holding down his teletypewriter space bar, depress
the pushbutton of the bias meter and watch the meter reading. Ifthe meter needle goes to the right of the zero mark, it indicates thatthe received signals have a positive or marking bias, and the knobof the Western Union 41-C relay should be turned counterclockwise (to the left) until the meter needle vibrates around the zeroposition. If the reading was to the left of the zero point, indicating negative or spacing bias, reduce the armature spring tensionof the relay by turning the adjusting knob of the relay clockwise
(to the right) until the meter needle vibrates around the zeroposition.
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
4 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
TM 11-2200 SIGNAL CORPS
<o-P g CM--
I .""
u °S< < z z
i; 8
O l-IH Z
Fig. 2. General Circuit of Bias Meter I-97-A.
6
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
4 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
BIAS METER I-97-A TM 11-2200
7-9
6. It is usually necessary to adjust the knob of the relay forzero bias under the following conditions :
(1) When the equipment is first put into operation on a
line.
(2) Whenever the line has been out of operation for morethan a short time.
(3) Whenever the received messages show any errors.
(4) Whenever line characteristics change because of moisture or humidity.
c. Note that the bias meter is adjusted to read zero bias on
a particular signal which is arbitrarily selected, and which is thesignal for a space in the teletype transmission code. The fact thata space signal is used to check bias adjustments has nothing to
do with "spacing" bias as read on the meter. Any signal can be
used for measuring bias, as long as the bias meter is adjustedto read zero when a perfect signal of the character selected isreceived by the bias meter. The space signal is selected because
it can be transmitted continuously and uniformly from a teletype
writer by holding down the space bar.
d. When working over long lines, it may not be possible toadjust the 41-C relay exactly to zero bias. However, it should beadjusted as closely to zero bias as possible. A small amount ofneedle vibration is always present when the meter is reading bias.
SECTION III—FUNCTIONING OF PARTS
8. General Circuit.
The general circuit of Bias Meter I-97-A is shown in Figure2. The reference numbers shown are the same as those listed inthe List of Maintenance Parts (see Par. 15).
9. Normal Operation.
The terminals of the relay subbase socket in the bias meterare connected in parallel with the terminals of the adapter plugwhen the pushbutton is unoperated. This causes the relay insertedin the socket in the bias meter to operate in the same way asthough it were in its own socket in Line Unit BE-77. Power is
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
4 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
TM 11-2200 SIGNAL CORPS9-11
supplied to the bias measuring network, but the meter is shortedout of the circuit, so that no indication is given. These connections
are shown in Figure 3.
RELAY SUBBASE SOCKET ADAPTER PLUG ( CONNECTS
IN BIAS METER 1-97-A TO LINE UNIT BE-77)
Fig. 3. Equivalent connections with pushbutton non-operated.
10. Bias Indication.
When the pushbutton is depressed, the short circuit aroundthe meter is removed and the 400-ohm resistor and the 0-400-ohm
rheostat are connected in series with the contacts of the relay tothe proper points in the bias measuring circuit. With the buttondepressed, terminals A and M of the relay subbase socket areshorted together through the adapter plug and the pushbuttoncontacts, thereby keeping the selector magnet of the telegraphprinter energized continuously and preventing it from "runningopen." These connections are shown in Figure 4.
11. Bias Measuring Circuit.
Looking at Figure 4, the circuit is of the Wheatstone-bridge
type with two equal and two unequal bridge arms. The bridge
arms are so proportioned (sized) that there is a reversal of cur
rent through the meter when the leg in which the relay contacts
are located is opened and closed. The reversed currents are ofsuch magnitudes that opening and closing of the relay contactsby repeated unbiased "space" signals will cause the meter to read
zero. Any bias in the signals to the relay will vary the percentage
8
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
4 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
BIAS METER I-97-A TM 11-2200
11-13
of open-circuit to closed-circuit time of each signal, causing the
meter to read to the right (indicating marking bias) or to the
WESTERN UNION 41-C RELAYIN SOCKET OF BIAS METER.
RELAY CONNECTIONS ARED-U' LINE COIL
©-©= BIAS COIL
S= SPACING CONTACT
A> MOVING CONTACTM= MARKING CONTACT
ADAPTER PLUG OF BIAS
METER IN RELAY SOCKETOF LINE UNIT BE-77.
Fig. 4. Equivalent Connections for Reading Bias (Pushbutton depressed).
left (indicating spacing bias). The meter needle is damped byan inductance and shunt capacitor, making the meter easier toread by reducing the vibration of the needle.
12. Use of Jack.
The jack is provided in Bias Meter I-97-A for patching theoutput of a Test Distributor, Teletype 100-A, or other source ofneutral type teletypewriter signals into the bias measuring circuit in place of the contacts of the relay. There should be no relayin the subbase of the bias meter when using the jack.
SECTION IV— MAINTENANCE
13. Servicing.
There will be little wear on any part of Bias Meter I-97-A.The relay, part of Line Unit BE-77, may possibly wear. Avoid
9
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
4 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
TM 11-2200 SIGNAL CORPS13-15
attempts at repairs in the field. It is more satisfactory to have
repairs made at the depot.
a. The meter used in the bias meter has a full-scale deflection
of one milliampere and therefore is subject to damage if carein servicing is not taken. If a test set is used to check the wiringof the bias meter, disconnect one of the meter leads because thebattery of the test set may pass sufficient current through themeter to damage it.
14. Zero Bias Adjustment.
An occasional check of the zero bias adjustment may be
required and should be by a maintenance group with proper test
equipment. Make the check by connecting a source of unbiasedrepeated "space" signals to the jack of the bias meter. Thesignals, which consist of marking pulse for the third and stop
impulses and a spacing pulse for the start, first, second, fourthand fifth impulses, preferably should be from a brush-type distributor such as No. 100-A Teletypewriter Test Distributor or a
14-Type Transmitter-Distributor, manufactured by the TeletypeCorporation. If the meter does not read zero while receiving the
unbiased signals with the pushbutton depressed, readjust the400-ohm rheostat located within the housing.
a. In order to make this adjustment, remove the sheet metalenclosure forming the sides and rear of the bias meter. Thenremove the cap nut from the rheostat shaft and adjust the rheo
stat with a screwdriver until a zero reading is obtained under theconditions previously described. Replace the cap nut and tightenit securely. If the meter does not read zero when the pushbuttonis not depressed, correct it with the zero adjusting screw on theface of the meter before adjusting the rheostat.
SECTION V—SUPPLEMENTARY DATA
15. Maintenance Parts.
All of the maintenance parts of Bias Meter I-97-A areshown in Figure 5. Descriptions, stock numbers, etc., are listedin the following pages. Each component has the same referencenumber in Figure 2 and Figure 5.
10
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
5 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
BIAS METER I-97-A TM 11-2200
ao
IO
S0
11
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
5 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
TM 11-2200 SIGNAL CORPS
1 *>6
0 Q*o CO M
H !j3(2
4J § 0i ° .(—
bo
|
ON "^
I *w F^ H g w g
M ^ "SMi.S ^^ *H
^ .g 3- .- fl "*.*+9 1* O M .J
Funct
ion
a> S1
c3"*"* oo n
"3 ri-P ol oo . Q>0
* a o M ..5 .53 g*jn ^3 '3 'Si'sw -s a V.J* p iiM A a
<u.s e-s s s a SSm Q1 ca fn o
ro w P. cs.JjM '(« ^=1 pill S 1
.3 t»g-guHH 4J* -M
S § »0 .S *^~) fl M w
en n .n
Sjl-^C S c3^j Q) 4JZ2 -4^ fiH
M8.a i> i* '"od .SSi^-gl .a^To
tf I -a
o w ge^ w c^
3 "ftH H"
o § 1 .* '*-
PA
RTS
FO
hen
requis
itio
n
com
ponent
listc
d
t)^ <J
£3 O3
and
Desc
ripti
o
5> So 6 s^°6
jj> oi oo C.S 23f^ ^ 'S * .S rt I"
*
" §4 . ^ --Sw"^^rxJ Jb*.^ h-. P *"r£_t^ W ^ 02 *
g
1
O M P^C™ . *PH ^ bX)'*O
e^M
t, <«
S M
-*j-~ 3 t* fl1""1.^
*T -° - eg 's'^co ^ CQ ^
H fi *-?? ® ^ f"1 M W 1^ 5^ ^^^j * QJ t *B E—
j
5s- .3
<o
^C 03 jf A .
2 J -HS5 ^ g
llll^l l^faW -g B IH 0 0>i s- f|* o?.g|^ •SoofS^bD-^ S'.-tig^ D» C «sa&rt.SH M-e^-l-^3 ft o5S o "-*^^ O 'w w .
<«! 5 s s
«Pft o
t™ ^ ^1°> S =
3
iH 2i-H 2CO J2 CT)
CO Jg 0IV. N 10
S <N 0L^ c/i p^o
s Icn .« «
ll i-H
| i «!o
i-l M M .<*
S nM
rH rH T-l rH
. o
S 2 Ho-.S
12
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
6 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
BIAS METER I-97-A TM 11-2200
8 i §
Use
din
bia
measu
ring
netw
ork
.
sed
inb
ia
measu
ring
netw
ork
.
sed
inb
ia
measu
ring
netw
ork
.
Use
din
bia
measu
ring
netw
ork
.
jf
o" a b
'3*0 C
g'h . g h .O QJ vS> O QJ vO
'T-I tS r1—' T-I &s-
x
O> * & 1O S*JWHS^eg" «HSi
00
C
um ng
"
2 I
.c.S^ uAi g'-Si
n]«]!nsHi'Wglfsg^lssff-i:3|I"#£^1*5 iIFliil^v> « ^ « -S c ^
^^jsssj1!iPlllfs'.!»
ia
§
o00
CONCO
101H<o
§
o
TI
N(M
I1
13
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
6 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
TM 11-2200 SIGNAL CORPS
S0 .eo 10 10
£,3 oo e»
Q« s 56 00
V CO1
«£1
Qg 8
!•CO CO
*'! H K m W
So s *
a 1j| o
! I 1 iil If£
"n o "S
1°a a
Nam
eof
Part
and
Desc
ripti
on
Tra
nsf
orm
er
C-6
0,
AF,
10
rati
o,
0"
x1
%"
x0
"hig
h,
4
mounti
ng
hole
s.1
00
"
dia
.on
Hi"
x1
&"
cente
rs.
Ferr
anti
C-6
0.
Volt
am
mete
rIS
-18
0,
1-0
-1m
a.,
ad
just
ed
to1
00
ohm
s±
%%
,sc
ale
10
0-0
-
10
0m
a.
(use
dw
ith
exte
rnal
shunt)
or
11
5-0
-11
5volt
s(u
sed
wit
hexte
rnal
mult
iplie
r)
,
D'A
rsonval
movem
ent,
flange
3%
"dia
.,body
0%
"dia
.x
1%
"
deep,
round
flush
mounti
ng,
mold
ed
case
,ca
libra
ted
for
-ft"
steel
panel.
#1
0-3
0te
rmin
al
studs
on
back
,%
"
long.
Mari
on
IS-1
80
.
Adapte
rPlu
gand
Cord
Ass
em
bly
,co
n
sist
sof
Refe
rence
Nos.
13
,1
6and
18
ass
em
ble
dto
geth
er.
(See
Fig.
0.)
Pow
er
Cord
Ass
em
bly
,0
-conduct
or
#1
8
rubber-
insu
late
d,
rubber
jack
ete
dco
rd,
36
"lo
ng,
wit
hB
eld
en
H-1
04
7att
ach
ment
plu
g.
Oth
er
end
has
conduct
ors
separa
ted
3"
and
skin
ned
W.
"d o eo CO
Q 1 i 1
10 8
. o Atsj
t- i o.£? +" eo Ww^ eo eo
"o
.s-g tHrH
M s o« £
P4 '
CO
S'l'l^iH
>H rH rt rt
cy.s
I
14
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
6 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
BIAS METER I-97-A TM 11-2200
.oo
"^SO M
s -+3C -g.sA
Q)-F-l
M B T3o So O So
"O u i 09 CO c 02 n ^>o
o
4on
transf
orm
er
sere
-
3
on
mete
rsc
rew
s
Wit
htr
ansf
orm
er
scre
o
0
on
Cab
leC
onnect
or
0
on
Cap
aci
tor
Mounti
Secu
res
Cab
leC
lam
p
pt
0
on
Cab
leC
onnect
or
0
on
Cap
aci
tor
Mounti
3
on
Resi
stor
Ass
em
b!
On
Resi
stor
Ass
em
bly
Mount
Tra
nsf
orm
er
Wit
hm
ete
rsc
rew
s
A 09
B .?
CO
qj
09
u
OQ
P(
Secu
reM
ete
r
13 S .§
S ffl
Nam
ep
late
X
o3y
£ QJ
3 1
B s a Q
o o o oQ> QJ
«
OQ 02
1 i * *k
CD es
4
O CM IN
CD
eg0) to
2
CO
CO S1 (N* 4
.•** .<#* CO * * *CD
* * * *
3 1 3 "S "o
| 1 £ 1 jjj
3 g A 0> s A 'S 3
1
B?
11
* I
"3
'3 .i
"3 i 1
09
i
TJ
1
"3,
'Sa
8
«
1
rC
'3 *s
s.
30 A
1t/
r1
O of
1
_N
1
A
'.a
1
'S"
1
OD « o
i .8s
s
03 w
"3 'a
03
1
S3
1
1 £
"S 1jf1
j-T
« .a J J V03 Pi
COw a ^? ™ 01"M
OB mrC "3
*
.s A
i 1
a
1
5
.S
.d'S
1
aQJ
.+3 0
n
1
« oi O9
g
a
w GOCO 03
1
03
1
CQ"d
-M
12 2*H• g
S
1M
3
"3ua
M
3S I
p< .OM
si
1
Sw
gSs S Soi .a
M S
1
03 M
aCO t- m
,03 J—( rH ,
CO
C?
cnr>
I
CQ
.T.cn
Hen
05
15
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
6 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
TM 11-2200 SIGNAL CORPS
M
3I« •
x-\ 0 Sao
,tch
toC
over
Connect
ion
SIi
'"O si
* * M||u 1~
£
en
DA
SH
ER
OS GJ oj c3=
s^o _gutfoo
nede I s0 O 0 0 oj C
»^
r-l<M CV1OJ co O
1 tJ
k
enM
S
CJQ Q).s
50 t 3
enm
JW ~^
H
O
CO
c/f
^
«T3
"Is 1
§ §
"5 3
| |
"§
&
1
S -3*
-3
5 s
.s « 'S
.<3 QH
£ 1 tf
1
[3 0j
1fa
1
O P*
O.FH yf-i o
S
"oS
q
GO ^,EQ ^J0] QJfH ^
oaCO W CO
L
"n c- N IN(4
<§
1
O
CO03
H
I
«PH
of
I
o>"a
1
et£.ate
^l«l-s55-^ § §3
. rf«1ll '"
PH
a)t>0rQ
CcJ of«M
c" o^
.SM
« . OS ft
'aj _i^st^ ^1
Ia!
S§
r a>a s
«ars«O S cj
60 s g|
r n -t->o S w
S a & fi 6O fl _MhH ^
ois c3 cj CD c3 o
a S S PS .s 'c09 X 4.* C -*-*.^ ft o . P o
C/2 >H 0> CIS O 0>
o O H
'.S M53
|S«
P? H
II 111lllSlg
v
I
16
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
6 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
[A.G. 300.7 (23 July, 1943) ]
BY ORDER OF THE SECRETARY OF WAR :
OFFICIAL :
J. A. ULIO,Major General,
The Adjutant General.
DISTRIBUTION :
X
(For explanation of symbols, see FM 21-6)
G. C. MARSHALL,Chief of Staff.
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
6 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle
Genera
ted o
n 2
01
5-1
2-0
3 1
8:4
6 G
MT /
htt
p:/
/hd
l.hand
le.n
et/
20
27
/uc1
.b3
24
54
84
Public
Dom
ain
, G
oog
le-d
igit
ized
/
htt
p:/
/ww
w.h
ath
itru
st.o
rg/a
ccess
_use
#pd-g
oogle