Upload
tranngoc
View
216
Download
1
Embed Size (px)
Citation preview
31 January 2017
AlphaRodTM CS
Tenaris Sucker Rods
“The information in this electronic mail is not intended to constitute professional or any other type of advice and is provided on an “as is” basis. No warranty is given. Tenaris has notindependently verified any information –if any- provided by petitioner in connection with, or for the purpose of, the information contained hereunder. Petitioner acknowledges and agrees thatthe use of the information is at user’s own risk and Tenaris does not assume any responsibility or liability of any kind for any loss, damage or injury resulting from, or in connection with anyinformation provided hereunder or the use thereof. Tenaris products and services are subject to the Company’s standard terms and conditions or otherwise to the terms resulting from therespective contracts of sale, services or license, as the case may be. Unless specifically agreed under such contract of sale, services or license, if petitioner requires Tenaris to provide anywarranty or assume any liability in connection with the information provided hereunder, any such warranty or liability shall be subject to the execution of a separate written agreementbetween petitioner and Tenaris. The information in this electronic mail is confidential and shall not be reproduced or disclosed in any form or by any means whatsoever, without priorpermission from Tenaris. For more complete information please contact a Tenaris's representative or visit our website at www.tenaris.com. ©Tenaris 2015. All rights reserved”.
2Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
In US +80% of the sucker rod failures are associated with
Fatigue or Corrosion-Fatigue
The operation conditions are becoming more challenging
3Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Development Premises
Operating Conditions
•Harsh environment, CO₂, H₂S, Chlorides
•High cyclic loads, temperature, pressure
•Water cut
Available options
•Standard industry steels
•Inhibition
•Lower strength material and oversized string design
R&D Inputs
•Develop a new series of Sucker Rods specially designed to:
•Increased corrosion-fatigue resistance,
•Capable to handle high loads
•Released at a market level price.
90% results in CF failures
4Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Development Process: Steel Design
Heat Treatment
• Full martensitic structure (95%)
• Tempered Martensite• Fine Ferrite Grains• Very fine Carbides
Ultra Clean Steel
• Highly controlled raw material
• Low Residuals:• Low P• Limited S & O
Chemical Composition
• Low Carbon• Micro Alloying: Cr,
Mo, Nb, B, Ti
Microstructure
Resulted in:• Fine grain/packet size distribution• Fine precipitates with high
spherical shape factor• Low dislocation density
AlphaRodTM
5Tenaris Sucker Rods Tenaris
AlphaRodTM
Metallurgical Concept
Normalized and Tempered rods
Standard Structure
AlphaRodTM
• Full martensitic structure (95%)• Tempered Martensite• Fine Ferrite Grains• Very fine Carbides
Perlite Bainite
6Tenaris Sucker Rods Tenaris
HS
500x
Center
AlphaRodTM CS
500x
Center
HS
500x
surface
AlphaRodTM CS
500x
surface
Grain size
~15 mm
Grain size
~4 mm
AlphaRodTM
Microstructure - Standard Rod vs AlphaRod™
7Tenaris Sucker Rods Tenaris
AlphaRodTM
Metallurgy Effect
Toughness
Fatigue Endurance
Microstructure
Corrosion Fatigue
8Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Introduction to Toughness
Fracture toughness is a property which describes the ability of a material containing a crack to resist
fracture
9Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Testing: Toughness
Increased toughness compared to Standard grades
KD 4320
UHS 4330
MMS 4138DA 4142
AlphaRod™ CS
Tenaris Norris Upco Weatherford Exceed
DA 4142 78 4142 AD 4142 D 4142 D
KD 4320 90 4320 KD 4720 KD 4720 EKD 3130
DS 4330 75 4330 S87 3130
MMS 4138 96 4138 HS 4138 T66/XD 4138 EH6 4138
UHS 4330 97 4330 HD 4332 EH7 4330
S88 3130 EHK 3130
10Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Introduction to Fatigue Failures
Paris Law
Threshold
11Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Testing: Fatigue Nucleation and crack growth rate
Threshold 25% Increased Threshold
Paris Law
1 10 100
1E-7
1E-6
1E-5
1E-4
1E-3
0.01
7.61
Fatigue crack growth:
Experim.; Best fit (Paris Law)
Q&T DS852, Gr. D: ; da/dN = 9.82E-10(K)3.28
N&T 4330, Gr.D: ; da/dN = 2.84E-9(K)3.18
Threshold:
Experim.; Best fit for threshold
Q&T DS852, Gr. D: ; (Kth= 9.46 MPa.m
0.5)
N&T 4330, Gr.D: ; (Kth= 7.61 MPa.m
0.5)
9.46
Q&T and N&T materials
Fa
tig
ue
cra
ck g
row
th r
ate
, d
a/d
N (
mm
/cycle
)
Stress intensity factor range, K (MPa.m0,5
)
AlphaRodTM CS
DS (4330M)
AlphaRodTM CS
DS (4330M)
ASTM E647
12Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Introduction to Fatigue Failures
Fatigue curve in salt water
Fatigue curve in air
Fatigue limit
N (no. of cycles)
S (
Str
ess /
Mpa)
S-N curve (Stress applied vs. Cycles until failure)
Corrosion-Fatigue Curve
13Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Testing: Fatigue Limit in Air
Improved fatigue resistance compared to Standard grades
AlphaRodTM CS
AlphaRodTM HS
AlphaRodTM CS
Standard N&T
Standard N&T
14Tenaris Sucker Rods 31 January 2017
• Liquid Solution simulating formation
water: pH~5.5
• Gas: CO2 + N2
• Temperature: 140F
• Pressure: 450psi
• Partial Prssure CO2: 145psi
• Loading: Mod Goodman @SF 1
~150% D, ~85% UHS
• Cycling frequency 20 cycles/min
(10 to 30 days each test)
AlphaRodTM
Lab test validation: Corrosion-Fatigue (CF)
CO2 H2S
• Liquid Solution: pH~4.5
• Gas: 100% H2S
• Temperature: 77F
• Pressure: 14psi
• Partial Prssure H2S: 14psi
• Loading: Smax=Mod Goodman
@SF 1= ~150% D, ~85% UHS
• Cycling frequency 20 cycles/min (10
to 30 days each test)
15Tenaris Sucker Rods Tenaris
Superior Corrosion Fatigue Performance in H2S and CO2 environments
Mechanical Properties Superior Toughness 2.25x vs API Grades
AlphaRodTM
Lab test validation: Summary
D A
llo
y
MM
SKD
UH
S
Alp
haR
od
™ C
S
D A
llo
y
MM
S
KD
UH
S
Alp
haR
od
™ C
S
Alpahrod™ 4x vs KD & UHSAlpahrod™ 2x vs KD & UHS
D A
llo
y
KD
Alp
haR
od
™ C
S
16Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Modified Goodman Diagram
* Service Factor 1
HS (SF:0.9)
AlphaRodTM can be simulated in SROD or
RODSTAR by MMS or UHS @ SF of 0.9
17Tenaris Sucker Rods Tenaris
AlphaRod™ Accesories are manufactured following the same quality standards andspecifications than AlphaRod™ in order to reach the identical characteristics andperformance than AlphaRod™ sucker rods:
• Couplings
• Grades: CS (Corrosion Service
• Sizes: 5/8” to 1 1/8” (FS and SH)
• BlueRod™ Sizes: 3/4” to 1” (FS and SH)
• Crossover Couplings
• Polished Rod Couplings
• Pony Rods
AlphaRodTM
Accesories
AlphaRod™ CS Coupling
After 112 operating days
T 8630 coupling
After 100 operating days
18Tenaris Sucker Rods Tenaris 31 January 2017
AlphaRodTM
Field Validation
XX1 XX2XX3 XX4
Last update: 12/31/2016
+60% of them already reach target and 4 of them
triple previous run time
11 strings installed in US in the last month
19Tenaris Sucker Rods Tenaris 31 January 2017
Concluding Remarks
The new steel notably increases the run life in corrosive
environments (CO2, H2S) at high loads (Capable of working up
to Modified Goodman Diagram for HS @ SF 0.9).
Steel Design Lab Testing Field Validation
6 years of R&D program
AlphaRodTM
31 January 2017
Questions?
Sucker Rods Division
“The information in this electronic mail is not intended to constitute professional or any other type of advice and is provided on an “as is” basis. No warranty is given. Tenaris has notindependently verified any information –if any- provided by petitioner in connection with, or for the purpose of, the information contained hereunder. Petitioner acknowledges and agrees thatthe use of the information is at user’s own risk and Tenaris does not assume any responsibility or liability of any kind for any loss, damage or injury resulting from, or in connection with anyinformation provided hereunder or the use thereof. Tenaris products and services are subject to the Company’s standard terms and conditions or otherwise to the terms resulting from therespective contracts of sale, services or license, as the case may be. Unless specifically agreed under such contract of sale, services or license, if petitioner requires Tenaris to provide anywarranty or assume any liability in connection with the information provided hereunder, any such warranty or liability shall be subject to the execution of a separate written agreementbetween petitioner and Tenaris. The information in this electronic mail is confidential and shall not be reproduced or disclosed in any form or by any means whatsoever, without priorpermission from Tenaris. For more complete information please contact a Tenaris's representative or visit our website at www.tenaris.com. ©Tenaris 2015. All rights reserved”.