BID CLARIFICATION #1 May 1, 2019 DUE DATE: May 9, 2019 TIME: 2:00 p.m. PROJECT: Student Union – QSR Dining Buildout Project Number: 300106 LOCATION: University of Connecticut Capital Projects & Facilities Procurement 3 Discovery Drive Storrs, CT 06269 Attn: Walt Dalia Please note the following information must be incorporated into your proposal for the Student Union – QSR Dining Buildout, Project #300106: 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3) Included are Drawings EP-101,T-001, & T-100 4) Included is a revised Section 012300 – Alternates. Alternate #1 has been added and attached is a revised Alternate Sheet that you are you use to replace the one in the Bid Submission/Form of Proposal. End of Bid Clarification #1

TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

BID CLARIFICATION #1 May 1, 2019 DUE DATE: May 9, 2019 TIME: 2:00 p.m. PROJECT: Student Union – QSR Dining Buildout Project Number: 300106 LOCATION: University of Connecticut Capital Projects & Facilities Procurement 3 Discovery Drive Storrs, CT 06269 Attn: Walt Dalia Please note the following information must be incorporated into your proposal for the Student Union – QSR Dining Buildout, Project #300106:

1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3) Included are Drawings EP-101,T-001, & T-100 4) Included is a revised Section 012300 – Alternates. Alternate #1 has been added and attached is a

revised Alternate Sheet that you are you use to replace the one in the Bid Submission/Form of Proposal.

End of Bid Clarification #1

Page 2: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)
Page 3: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

unc-4721

addendum no. 01

page 1

Addendum No. 01

To

The Contract Documents For

The Construction Of

Food Court Station

Asian Concept

UCONN - Student Union Building

Storrs, CT

edm Project No. unc-4721

UConn Project No. 201687

04.25.19

This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated 04.05.19 as noted below. Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject the Bidder to disqualification.

This Addendum is comprised of Page Nos. 1 through 2, and the following attachments:

Previously issued revised Drawings:

EP-101 FIRST FLOOR POWER AND LIGHTING PLAN

New Drawings:

T-001 TELCOM LEGEND

T-101 TELCOM FLOOR PLAN

Previously issued revised Specifications:

n/a

New Specification Sections:

012300 ALTERNATES

Sketch Drawings:

n/a

CONTRACTOR QUESTIONS

1. Special Inspections: will we need independent testing for any of the steel installation? No independent testing is required.

Page 4: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

unc-4721

addendum no. 01

page 2

2. There already is a temporary wall in front of the work area. Is that to remain? No, the contractor shall include removal of the existing temporary wall and the installation of another temporary wall.

3. Are there areas on site for dumpsters and parking? There will be space for minimal parking and limited dumpsters outside of the student union building. Contractor to coordinate exact allowable space with University.

4. Can you tell me the heights and font of the dimensional signage shown on A-102? For the larger sign (main sign) the short lowercase characters are approx. 9” tall and the tall lowercase letters are approx. 13” tall. For the smaller signs (side signs) the short lowercase characters are approx. 4” tall and the tall lowercase letters are approx. 5” tall.

DRAWINGS

n/a

SPECIFICATIONS

n/a

END OF ADDENDUM

Page 5: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

H

D

G

C

DD

D

DDD

6

9 10 1116

18 19

J

21

J

21A

25

J

34

J

41

23

30

32

J J

J

25

J J

J

00

J

J

H

D

G

C

DD

D

DDD

a b cD

cD

a bXL XM

KPL1D-27

KLP1D-2 SUBPANEL

KPL1D-213

KPL1D-222

KPL1D-215

KPL1D-216

KPL1D-230,32

KPL1D-221,23

KLP1D-2 SUBPANEL

31 KLP1D-2 SUBPANEL

33

KLP1D-2 SUBPANEL

35

KPL1D-214

1 1 1 1 1

2 2KPL1D-2

24

KLP1D-2 SUBPANEL20,22

KLP1D-2 SUBPANEL24,26

XM

XM

3

KPL1D-226

KPL1D-2

KPL1D-231,33,35

KPL1D-228KPL1D-2

19

XM XM XM XM XM XM

XM

XM

XMXM

XM

XM

XM

XM

XL XN

KPL1D-225

XM

1

ALL TELECOM DEVICES MOVED TO TELECOM DRAWING T-100

1

A

A

A A

A A A A

A

C C C

C C

B B B B B B

B

BBBBBB

XM

XM

XM

XMXM

XMKLP1D-2 SUB

PANEL37

KLP1D-2 SUBPANEL

40

KLP1D-2 SUBPANEL

39

XM

a

a

KPL1D-2 SUBPANEL

KPL1D-2 a a

a a

a a a

b

b b b b

c c c c c c

c

c c c c c c

XN

XN

ELU

ELU

1

PROJECT:

CERTIFICATION:

REVISIONS:MARK DATE DESCRIPTION

CONSULTANT:

UN

IVER

SITY

OF

CON

NEC

TICU

TA

CA

DE

MIC

RE

NO

VA

TIO

NS

DE

POT

CAM

PUS-

COLU

MBI

A B

UIL

DIN

G 5

SU

ERM

AN

PLA

CE, U

NIT

510

6 S

TORR

S, C

ON

NE

CTIC

UT

0626

9-30

38TE

LEPH

ON

E: (

860)

486

-312

7

SCALE:PRINT DATE:

DRAFTER:

PROJECT NO:

SHEET TITLE:

WORK ORDER NO:FILE NAME:

SHEET:

STATUS:

Stor

rs C

ampu

s

Stor

rs, C

T. 0

6269

Food

Cou

rt St

atio

n

AUTHOR:

architecture

201687

bidding and permitting

N

Asia

n Co

ncep

t

Stud

ent U

nion

Bui

ldin

g

Uni

vers

ity o

f Con

nect

icut

FACS

IMIL

E: (8

60) 4

86-3

177

engineering

management

pittsfield, maunionville, ct

(888) [email protected]

1/4" = 1'-0"

4/22/2019ADDENDUM 1

first floor power andlighting plan

EP-101

04.05.191/4" = 1'-0"1 electrical power plan1/4" = 1'-0"2 electrical lighting plan

Keyed notes:

RECEPTACLE AND FOR MENU MONITOR. MOUNT VERTICALLY IN SOFFIT. COORDINATE EXACT LOCATION WITH MONITOR INSTALLER. EXTEND EXISTING BRANCH CIRCUIT WIRING, RELOCATED TO ALLOW FOR DEMOLITION, TO NEW EQUIPMENT LOCATION. CONTRACTOR TO VERIFY THE INTEGRITY OF EXISTING WIRING IS SUFFICIENT PRIOR TO CONNECTION TO EQUIPMENT. PROVIDE 4”SQ BY 2 1/4" DEEP METAL JBOX WITH 1-GANG MUD RING FLUSH MOUNTED IN SOFFIT.

POINT OF SALE WORK STATION. PROVIDE (1) DUPLEX RECEPTACLE. RECEPTACLE TO BE FED FROM BRANCH CIRCUIT WIRING THAT WAS RELOCATED TO ALLOW FOR DEMOLITION. COORDINATE DATA JACK AND DUPLEX RECEPTACLE LOCATION WITH KITCHEN EQUIPMENT INSTALLER.

EXTEND EXISTING BRANCH CIRCUIT WIRING, MOVED FOR DEMOLITION TO RELOCATED EQUIPMENT. CONTRACTOR TO VERIFY THAT THE INTEGRITY OF EXISTING WIRING IS SUFFICIENT TO CONTINUE IN OPERATION PRIOR TO CONNECTION TO EQUIPMENT.

General notes:

1.

2.

3.

ELECTRICAL CONTRACTOR SHALL VERIFY WITH KITCHEN EQUIPMENT CONTRACTOR ALL EQUIPMENT LOCATIONS, NAMEPLATE INFORMATION (FOR UNIT LINE VOLTAGE, HORSEPOWER, AMPACITY,PHASE, ETC.) PRIOR TO THE START OF WORK. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL POWER CONDUITS AND WIRING AS REQUIRED.

REFER TO KITCHEN EQUIPMENT SCHEDULES FOR ADDITIONAL INFORMATION.

UPON ACTIVATION OF ANY FIRE EXTINGUISHING SYSTEM FOR COOKING OPERATION, ALL SOURCES OF FUEL AND ELECTRICAL POWER THAT PRODUCE HEAT TO ALL EQUIPMENT REQUIRING PROTECTION BY THAT SYSTEM SHALL BE AUTOMATICALLY SHUT OFF. IN ADDITION TO THE REQUIREMENTS FOUND IN THE CONSTRUCTION DOCUMENTS, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF WRING TO GAS SHUT-OFF VALVES. AND MICROSWITCH FROM FIRE SUPPRESSION SYSTEM. ANSUL SYSTEM IS EXISTING TO REMAIN

PROVIDE GFI PROTECTION FOR ALL SINGLE-PHASE RECEPTACLES RATED 120V, 50 AMPS OR LESS AND THREE-PHASE RECEPTACLES RATED 120V, 100 AMPS OR LESS, IN ACCORDANCE WITH 2017 NEC ARTICLE 210.8(B).

LOAD VALUES AND CONNECTION TYPES ARE BASED OFF PRELIMINARY KITCHEN EQUIPMENT CONSULTANTS DESIGN. VALUES ARE SUBJECT TO CHANGE. COORDINATE ALL EQUIPMENT INFORMATION WITH KITCHEN EQUIPMENT CONTRACTOR AND OWNERS REPRESENTATIVE PRIOR TO PURCHASING MATERIALS.

A.

B.

C.

D.

E.

#1

1

MENU MONITOR RECEPTACLE COUNT CHANGED FROM 5 TO 6

1

Page 6: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

TECHNOLOGY ABBREVIATIONS(NOTE: NOT ALL ABBREVIATIONS APPLICABLE)

-am

A.F.F.A.F.G.AMPARCH.AWGBCTBICSI

-cCCATCATVCCTVCLG.CPUCTD

E.C.EFEIAELECEMIEMT-fFFDFOPPF&IGG.C.GEGECHHVACIGIDFIWBLANMDFNECNICPAPBXPCPoEPPPRPVCQTYRU-rSTTBBTGBTIATMGBTRTVTYPU.N.O.UPSUTPVVGAVoIPWWG

ABOVE FINISH FLOORABOVE FINISH GRADEAMPEREARCHITECTAMERICAN WIRE GAUGEBONDING CONDUCTOR FOR TELECOMMUNICATIONSBUILDING INDUSTRY CONSULTING SERVICEINTERNATIONALAT CEILING OR IN CEILING TILE, LOCATION OF DEVICECONDUIT(S)CATEGORY ETHERNET CABLECOMMUNITY ANTENNA TELEVISION (CABLE TELEVISION)CLOSED CIRCUIT TELEVISIONCEILINGCENTRAL PROCESSING UNITCABLE TRAYDATA

DEMARCDP DEMARCATION POINT

ELECTRICAL CONTRACTORENTRANCE FACILITYELECTRONICS INDUSTRIES ALLIANCEELECTRICALELECTROMAGNETIC INTERFERENCEELECTRICAL METALLIC TUBINGAT FLOOR OR IN THE FLOOR, LOCATION OF DEVICEFACSIMILE (FAX)FLOOR DISTRIBUTIONFIBER OPTIC PATCH PANELFINISHED AND INSTALLEDGROUNDGENERAL CONTRACTORGROUNDING EQUALIZERGROUNDING ELECTRODE CONDUCTORHIGH DEVICEHEATING, VENTILATION AND AIR CONDITIONINGISOLATED GROUNDINTERMEDIATE DISTRIBUTION FRAMEINTERACTIVE WHITE BOARDLOCAL AREA NETWORKMAIN DISTRIBUTION FRAMENATIONAL ELECTRICAL CODENOT IN CONTRACTPUBLIC ADDRESSPRIVATE BRANCH EXCHANGEPERSONAL COMPUTERPOWER OVER ETHERNETPATCH PANELPAIRPOLYVINYL CHLORIDE CONDUITQUANTITYRACK UNITIN RACEWAY ABOVE MILLWORK, MOUNTING LOCATIONSLEEVE(S)TELEPHONE (VOICE)TELECOMMUNICATIONS BONDING BACKBONETELECOMMUNICATIONS GROUNDING BUSBARTELECOMMUNICATIONS INDUSTRY ASSOCIATIONSTELECOMMUNICATIONS MAIN GROUNDING BUSBARTELECOMMUNICATIONS ROOMTELEVISIONTYPICALUNLESS NOTED OTHERWISEUNINTERRUPTIBLE POWER SUPPLYUNSHIELDED TWISTED PAIRVIDEOVIDEO GRAPHICS ARRAYVOICE OVER INTERNET PROTOCOLWALL TELEPHONE (VOICE)WIRE GURD

WANWAOWAPWP

WIRELESS (DATA) ACCESS POINTWEATHERPROOF IN USE ENCLOSURE

ABOVE MILLWORK, COORDINATE LOCATIONWITH MILLWORK OR FURNITURE SYSTEM

DEMARCATION

WORK AREA OUTLETWIDE AREA NETWORK

2. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORKINCLUDED IN THE CONTRACT. COORDINATE LOCATIONS OF EQUIPMENT WITH ALL OTHER TRADESBEFORE STARTING CONSTRUCTION.

3. COORDINATE WITH CONSTRUCTION MANAGER, OTHER TRADES AND THE OWNER DURING ALL PHASES.ALL COMMUNICATIONS, SYSTEMS, DEVICES AND WIRING MUST BE MAINTAINED AT ALL TIMES UNLESSPHASING REQUIRES OTHERWISE. INTERRUPTIONS AND SHUTDOWNS WILL BE SCHEDULED IN ADVANCEAND APPROVED FOR TIME TO COMPLETE WORK. TAG CABLES TO REMAIN DURING ALL PHASES TOPROPERLY KEEP THE TELECOMMUNICATIONS ACTIVE. UPON COMPLETION OF CONSTRUCTION, ANYCABLES THAT ARE NOT ACTIVE OR TAGGED TO REMAIN FOR FUTURE USE WILL BE REMOVED END TOEND AS PER THE NEC.

4. BEFORE CONSTRUCTION CAN BEGIN IN ANY COMMUNICATIONS EQUIPMENT ROOM THE CONTRACTORSHALL CONFIRM SUFFICIENT CAPACITY EXIST ON EXISTING SYSTEM.

5. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATION AND MOUNTING HEIGHTS OFEQUIPMENT. ALL SUCH EQUIPMENT AND COLORS SHALL BE COORDINATED WITH THE ARCHITECT.CONTACT ARCHITECT FOR CLARIFICATION OF MOUNTING REQUIREMENTS, ARCHITECTURAL HEIGHTSAND DIMENSIONS SUPERSEDE THOSE AS INDICATED ON THESE DRAWINGS

6. COORDINATE AND REFER TO REFLECTIVE CEILING PLANS FOR FLUSH MOUNTED CEILING DEVICES.

7. PROVIDE SEPARATION BETWEEN RACEWAY, CABLES AND OTHER SOURCES (EMI) PERANSI/TIA/EIA-569-A AND ADDENDUMS.

8. ELBOW RADIUS FOR RACEWAYS SMALLER THAN 2" TO BE (6) TIMES THE RACEWAY DIAMETER.

9. ALL EMPTY RACEWAYS SHALL BE PROVIDED WITH A PLENUM RATED, NYLON PULL CORD.10. COORDINATE PROPER METHODS FOR PENETRATIONS WITH FIRESTOPPING AS REQUIRED THROUGH

FIRE/SMOKE RATED CONSTRUCTION PER DIVISION 07 8413 SPECIFICATIONS.

11. CONDUITS, SLEEVES, AND J-HOOKS FROM IDF TO THE WORK AREAS OUTLETS/ CONNECTORS. REFER TO DIVISIONS 26 SPECIFICATIONS FOR HANGERS AND SUPPORT12. COORDINATE OUTLET INSTALLATIONS, WALL, RECESSED OR SURFACE; CEILING; FLOOR: SLEEVE OR

INFLOOR SYSTEM; UTILITY COLUMN; PER TECHNOLOGY/ELECTRICAL POWER DRAWINGS AND DIVISION26 SPECIFICATIONS.

13. CONTRACTOR TO ENSURE ALL SLEEVES (LESS THAN 4 FEET) SHALL BE MAXIMUM 60% FILL FOR ALLCABLING AND MAXIMUM 40% FILL FOR ALL CONDUITS AND RACEWAYS.

TECHNOLOGY TRADE NOTES:THE TELECOMMUNICATIONS CONTRACTOR SHALL FURNISH AND INSTALL ALL WIRING, (INCLUDING WIRING IN ACCESSIBLECEILING) DEVICE BRACKETS, CONNECTORS, FACEPLATES, TERMINATION MATERIALS,PATHWAYS INCLUDING CONDUIT, SLEEVES, BUSHINGS, BACK BOXES, PULL LINES, ANDBLANK FACEPLATES AS INDICATED ON THE DRAWINGS FOR THE DATA NETWORK AND VOICE/PHONE SYSTEM.

THE LOCAL SOUND CONTRACTOR SHALL FURNISH AND INSTALL ALL WIRING, (INCLUDING WIRING IN ACCESSIBLECEILING) DEVICE BRACKETS, CONNECTORS, FACEPLATES, TERMINATIONS PATHWAYS INCLUDING CONDUIT, SLEEVES, BUSHINGS, BACK BOXES, PULL LINES, BLANK FACEPLATES WHERE REQUIRED FOR ALL LOCAL SOUND SYSTEMS. THE LOCAL SOUND CONTRACTOR SHALL PROVIDE REQUIRED CABLING AND INTERFACE WITH THE FIRE ALARMTHE CONTRACTOR SHALL PROVIDE A DRY CONTACT CABLING FOR SHUNTING THE SOUND SYTEM

TECHNOLOGY COMMUNICATIONS GENERAL NOTES(NOTE: APPLIES TO ALL TECHNOLOGY DRAWINGS)

1. SEE ELECTRICAL POWER AND TECHNOLOGY DRAWINGS FOR PLANS, DIAGRAMS AND DETAILSPERTAINING TO THIS PROJECT.

GENERAL NOTE (APPLIES TO ALL SYSTEMS):THE CONTRACTOR HAS THE RESPONSIBILITY TO SURVEY AND FIELD VERIFY EXISTING SYSTEMSEQUIPMENT AND PROVIDE THE NECESSARY QUANTITIES OF ITEM(S) TO MAKE A FULLY FUNCTIONINGSYSTEM(S) AS DELINEATED IN THE SPECIFICATIONS AND/OR DRAWINGS ASSOCIATED WITH THEPROJECT.

A.

B.

14. WAO BOXES SHALL BE A MINIMUM OF 4-11/16"H x 4-11/16"W x 2-1/8"D WITH A SINGLE GANG PLASTIC RING. EACH WAO BOX SHALL HAVE A MINIMUM TRADE SIZE 1 CONDUIT STUBBED TO AN ACCESSIBLE CEILING SPACE OR CABLE TRAY. CONDUIT OPENINGS SHALL BE BUSHED TO PROTECT CABLES FROM DAMAGE.

WAP WIRELESS ACCESS POINT ABOVE CEILING. CONTRACTOR TO PROVIDE CAT 6 CABLE HOME RUN TO IDF.

DATA OUTLET LOCATION, MH = 18" AFF, UON. SINGLE GANG OUTLET BOX WITH(1) 1"EMT TO SPACE ABOVE CEILING IN CORRIDOR. PROVIDE PLASTER RING. # INDICATES TOTAL NUMBER OF CAT 6 JACKS AND CABLES REQUIRED.

1

TELECOM LEGEND

DATA/PHONE OUTLET LOCATION, MH = 18" AFF, UON. SINGLE GANG OUTLET BOX WITH(1) 1"EMT TO SPACE ABOVE CEILING IN CORRIDOR. PROVIDE PLASTER RING. ONE CAT 6 JACK/CABLE AND ONE TELEPHONE JACK/CABLE REQUIRED.

2

DATA OUTLET LOCATION, MH = 18" AFF, UON. SINGLE GANG OUTLET BOX WITH(1) 1"EMT TO SPACE ABOVE CEILING IN CORRIDOR. PROVIDE PLASTER RING. TWO CAT 6 JACKS/CABLES AND ONE TELEPHONE JACK/CABLE REQUIRED.

3

DATA OUTLET LOCATION, MH = 18" AFF, UON. DOUBLE GANG OUTLET BOX WITH(1) 1"EMT TO SPACE ABOVE CEILING IN CORRIDOR. PROVIDE PLASTER RING. THREE CAT 6 JACKS/CABLES AND ONE TELEPHONE JACK/CABLE REQUIRED.

4

AUDIO LEGENDCEILING MOUNTED SPEAKERA = RECESSED MOUNTED SPEAKER IN ACP CEILINGB = RECESSED MOUNTED SPEAKER IN GYPSUM WALL BOARD CEILINGC = PENDANT MOUNTED SPEAKER

SURFACE OR WALL MOUNTED AMPLIFIER

MASTER CONTROL STATION

INTERCOM STATION

SP

AMP

MCS

IC

A,B,C

MIX MIXER

1

PROJECT:

CERTIFICATION:

REVISIONS:MARK DATE DESCRIPTION

CONSULTANT:

UN

IVER

SITY

OF

CON

NEC

TICU

TA

CA

DE

MIC

RE

NO

VA

TIO

NS

DE

POT

CAM

PUS-

COLU

MBI

A B

UIL

DIN

G 5

SU

ERM

AN

PLA

CE, U

NIT

510

6 S

TORR

S, C

ON

NE

CTIC

UT

0626

9-30

38TE

LEPH

ON

E: (

860)

486

-312

7

SCALE:PRINT DATE:

DRAFTER:

PROJECT NO:

SHEET TITLE:

WORK ORDER NO:FILE NAME:

SHEET:

STATUS:

Stor

rs C

ampu

s

Stor

rs, C

T. 0

6269

Food

Cou

rt St

atio

n

AUTHOR:

architecture

201687

bidding and permitting

N

Asia

n Co

ncep

t

Stud

ent U

nion

Bui

ldin

g

Uni

vers

ity o

f Con

nect

icut

FACS

IMIL

E: (8

60) 4

86-3

177

engineering

management

pittsfield, maunionville, ct

(888) [email protected]

12" = 1'-0"

4/22/2019ADDENDUM 1

telecom legend

T-001

04.05.19

1

Page 7: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

H

D

G

C

DD

D

DDD

DIVISION 27 CABLING

HORIZONTAL CABLING DESCRIPTION

A. HORIZONTAL CABLE AND ITS CONNECTING HARDWARE PROVIDE THE MEANS OF TRANSPORTING SIGNALS BETWEEN THE TELECOMMUNICATIONS OUTLET/CONNECTOR AND THE HORIZONTAL CROSS-CONNECT LOCATED IN THE COMMUNICATIONS EQUIPMENT ROOM. 1. HORIZONTAL CABLING SHALL CONTAIN NO MORE THAN ONE TRANSITION POINT OR CONSOLIDATION POINT BETWEEN THE HORIZONTAL CROSS- CONNECT AND THE TELECOMMUNICATIONS OUTLET/CONNECTOR.2. BRIDGED TAPS AND SPLICES SHALL NOT BE INSTALLED IN THE HORIZONTAL CABLING.3. SPLITTERS SHALL NOT BE INSTALLED AS PART OF THE OPTICAL FIBER CABLING.

B. THE MAXIMUM ALLOWABLE HORIZONTAL CABLE LENGTH IS 295 FEET. THIS MAXIMUM ALLOWABLE LENGTH DOES NOT INCLUDE AN ALLOWANCE

UTP CABLE

A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING OR AN APPROVED EQUAL:1. BELDEN INC.2. COMMSCOPE, INC.3. GENESIS CABLE PRODUCTS; HONEYWELL INTERNATIONAL, INC.4. 3M COMMUNICATION MARKETS DIVISION.

B. DESCRIPTION: FOUR-PAIR UTP COVERED WITH A COLORED THERMOPLASTIC JACKET.1. COMPLY WITH ICEA S-90-661 FOR MECHANICAL PROPERTIES.2. COMPLY WITH TIA/EIA-568-B.1 FOR PERFORMANCE SPECIFICATIONS.3. COMPLY WITH TIA/EIA-568-B.2, CATEGORY 6.4. LISTED AND LABELED BY AS COMPLYING WITH UL 444 AND NFPA 70 FOR THE FOLLOWING TYPES:

A. COMMUNICATIONS, GENERAL PURPOSE: TYPE CM OR CMG.B. COMMUNICATIONS, PLENUM RATED: TYPE CMP, COMPLYING WITH NFPA 262.C. COMMUNICATIONS, RISER RATED: TYPE CMR[; COMPLYING WITH UL 1666.D. COMMUNICATIONS, LIMITED PURPOSE: TYPE CMX.E. MULTIPURPOSE: TYPE MP OR MPG.F. MULTIPURPOSE, PLENUM RATED: TYPE MPP, COMPLYING WITH NFPA 262.G. MULTIPURPOSE, RISER RATED: TYPE MPR, COMPLYING WITH UL 1666.

UTP CABLE HARDWARE(RACKS, PATCH PANELS AND DATA JACKS)

A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING OR AN APPROVED EQUIVALENT:1. AMERICAN TECHNOLOGY SYSTEMS INDUSTRIES, INC.2. BELDEN INC.3. HUBBELL PREMISE WIRING.4. LEVITON COMMERCIAL NETWORKS DIVISION.

B. GENERAL REQUIREMENTS FOR CABLE CONNECTING HARDWARE: COMPLY WITH TIA/EIA-568-B.2, IDC TYPE, WITH MODULES DESIGNED FOR PUNCH-DOWN CAPS OR TOOLS. CABLES SHALL BE TERMINATED WITH CONNECTING HARDWARE OF SAME CATEGORY OR HIGHER.

C. CONNECTING BLOCKS:. INTEGRAL WITH CONNECTOR BODIES, INCLUDING PLUGS AND JACKS WHERE INDICATED.

D. CROSS-CONNECT: MODULAR ARRAY OF CONNECTING BLOCKS ARRANGED TO TERMINATE BUILDING CABLES AND PERMIT INTERCONNECTION BETWEEN CABLES.1. NUMBER OF TERMINALS PER FIELD: ONE FOR EACH CONDUCTOR IN ASSIGNED CABLES.

E. PATCH PANEL: MODULAR PANELS HOUSING MULTIPLE-NUMBERED JACK UNITS WITH IDC-TYPE CONNECTORS AT EACH JACK FOR PERMANENT TERMINATION OF PAIR GROUPS OF INSTALLED CABLES. 1. NUMBER OF JACKS PER FIELD: ONE FOR EACH FOUR-PAIR CONDUCTOR GROUP OF INDICATED CABLES, PLUS SPARES AND BLANK POSITIONS ADEQUATE TO SUIT SPECIFIED EXPANSION CRITERIA.

F. JACKS AND JACK ASSEMBLIES: MODULAR, COLOR-CODED, TWO-POSITION MODULAR RECEPTACLE UNITS WITH INTEGRAL IDC-TYPE TERMINALS.

G. PATCH CORDS: FACTORY-MADE, FOUR-PAIR CABLES IN 36-INCH LENGTHS; TERMINATED WITH EIGHT-POSITION MODULAR PLUG AT EACH END.1. PATCH CORDS SHALL HAVE BEND-RELIEF-COMPLIANT BOOTS AND COLOR-CODED ICONS TO ENSURE CATEGORY 6 PERFORMANCE. PATCH CORDS SHALL HAVE LATCH GUARDS TO PROTECT AGAINST SNAGGING.2. PATCH CORDS SHALL HAVE COLOR-CODED BOOTS FOR CIRCUIT IDENTIFICATION.

1 1 1 1

2 2

WALL PHONE3

4

1 1

1

PROJECT:

CERTIFICATION:

REVISIONS:MARK DATE DESCRIPTION

CONSULTANT:

UN

IVER

SITY

OF

CON

NEC

TICU

TA

CA

DE

MIC

RE

NO

VA

TIO

NS

DE

POT

CAM

PUS-

COLU

MBI

A B

UIL

DIN

G 5

SU

ERM

AN

PLA

CE, U

NIT

510

6 S

TORR

S, C

ON

NE

CTIC

UT

0626

9-30

38TE

LEPH

ON

E: (

860)

486

-312

7

SCALE:PRINT DATE:

DRAFTER:

PROJECT NO:

SHEET TITLE:

WORK ORDER NO:FILE NAME:

SHEET:

STATUS:

Stor

rs C

ampu

s

Stor

rs, C

T. 0

6269

Food

Cou

rt St

atio

n

AUTHOR:

architecture

201687

bidding and permitting

N

Asia

n Co

ncep

t

Stud

ent U

nion

Bui

ldin

g

Uni

vers

ity o

f Con

nect

icut

FACS

IMIL

E: (8

60) 4

86-3

177

engineering

management

pittsfield, maunionville, ct

(888) [email protected]

As indicated

4/22/2019ADDENDUM 1

telecom floor plan

T-100

04.05.19

Keyed notes:

DATA JACK FOR MENU MONITOR. MOUNT VERTICALLY IN SOFFIT. COORDINATE EXACT LOCATION WITH MONITOR INSTALLER. REROUTE EXISTING DATA CABLING THAT WAS TEMPORARILY RELOCATED TO ALLOW FOR DEMOLITION, TO NEW EQUIPMENT LOCATION. CONTRACTOR TO VERIFY THAT THE LENGTH AND INTEGRITY OF THE DATA CABLES IS SUFFICIENT. IF LENGTH IS INSUFFICIENT. DATA CABLING SHALL BE REPLACED WITH NEW CABLING TO NEW LOCATION. FOR EACH TELECOMMUNICATIONS OUTLET PROVIDE 4”SQ BY 2 1/4" DEEP METAL JBOX WITH 1-GANG MUD RING FLUSH MOUNTED IN SOFFIT. PROVIDE 3/4" CONDUIT WITH PLASTIC BUSHING AND PULLSTRING TO ABOVE ACCESSIBLE CEILING.

POINT OF SALE WORK STATION. PROVIDE (1) RJ45 JACK AND CONNECT TO EXISTING CABLING THAT WAS RELOCATED FOR DEMOLITION. COORDINATE DATA JACK LOCATION WITH KITCHEN EQUIPMENT INSTALLER.

PROVIDE DATA JACK AND CABLING FOR WALL MOUNTED PHONE. PROVIDE 4”SQ BY 2 1/4" DEEP METAL JBOX WITH 1-GANG MUD RING FLUSH MOUNTED 48" AFF, UON. PROVIDE 3/4" CONDUIT WITH PLASTIC BUSHING AND PULLSTRING TO ABOVE ACCESSIBLE CEILING. CAT6 CABLE SHALL BE ROUTED BACK TO THE 110 VOICE BLOCK IN THE TR AND TERMINATED/LABELED THERE.

PROVIDE (2) JUNCTION BOXES FOR SECURITY CAMERA INSTALLATION ALONG WITH CAT6 CABLING FROM EACH JUNCTION BOX BACK TO HEADEND ROOM 124. PROVIDE CAT 6 CABLES WITH LENGTH CAPABLE OF REACHING ANYWHERE WITHIN PROJECT AREA. CONTRACTOR SHALL COORDINATE ROUTING OF CABLE WITH OWNERS REPRESENTATIVE.

General notes:

1.

2.

3.

4.

REROUTE EXISTING DATA CABLING, THAT WAS REMOVED DURING DEMOLITION, TO NEW EQUIPMENT LOCATION. CONTRACTOR TO VERIFY THAT THE LENGTH AND INTEGRITY OF EXISTING CABLING PRIOR TO CONNECTION TO EQUIPMENT. IF LENGTH IS INSUFFICIENT. DATA CABLING SHALL BE REPLACED WITH NEW CABLING. CONTRACTOR SHALL PULL CABLE FROM EQUIPMENT LOCATION TO HEADEND ROOM 124. CONTRACTOR SHALL COORDINATE ROUTING OF CABLE WITH OWNERS REPRESENTATIVE. ALL CABLING THAT IS NOT USED FOR NEW EQUIPMENT SHALL BE REMOVED AND DISPOSED OF.

ELECTRICAL CONTRACTOR SHALL VERIFY WITH KITCHEN EQUIPMENT CONTRACTOR ALL EQUIPMENT LOCATIONS, NAMEPLATE INFORMATION (FOR UNIT LINE VOLTAGE, HORSEPOWER, AMPACITY,PHASE, ETC.) PRIOR TO THE START OF WORK. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL POWER CONDUITS AND WIRING AS REQUIRED.

REFER TO KITCHEN EQUIPMENT SCHEDULES FOR ADDITIONAL INFORMATION.

FOR EACH TELECOMMUNICATIONS OUTLET PROVIDE 4”SQ BY 2 1/4" DEEP METAL JBOX WITH 1-GANG MUD RING FLUSH MOUNTED 18" AFF, UON. PROVIDE 1" CONDUIT WITH PLASTIC BUSHING AND PULLSTRING TO ABOVE ACCESSIBLE CEILING.

A.

B.

C.

D.

#

1

Page 8: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

Food Court Station Asian Concept unc-4721Student Union Building ALTERNATESUniversity of Connecticut, Storrs, CT 012300 - 1

SECTION 012300 - ALTERNATES

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section includes administrative and procedural requirements for alternates.

1.3 DEFINITIONS

A. Alternate: An amount proposed by bidders and stated on the Bid Form for certain work defined in the bidding requirements that may be added to or deducted from the base bid amount if Owner decides to accept a corresponding change either in the amount of construction to be completed or in the products, materials, equipment, systems, or installation methods described in the Contract Documents.

1. Alternates described in this Section are part of the Work only if enumerated in the Agreement.

2. The cost or credit for each alternate is the addition to or deduction from the Contract Sum to incorporate alternate into the Work. No other adjustments are made to the Contract Sum and Contract Time.

1.4 PROCEDURES

A. Coordination: Revise or adjust affected adjacent work as necessary to completely integrate work of the alternate into Project.

1. Include as part of each alternate, miscellaneous devices, accessory objects, and similar items incidental to or required for a complete installation whether or not indicated as part of alternate.

B. Notification: Immediately following award of the Contract, notify each party involved, in writing, of the status of each alternate. Indicate if alternates have been accepted, rejected, or deferred for later consideration. Include a complete description of negotiated revisions to alternates.

C. Execute accepted alternates under the same conditions as other work of the Contract.

D. Schedule: A schedule of alternates is included at the end of this Section. Specification Sections referenced in schedule contain requirements for materials necessary to achieve the work described under each alternate.

E. Alternates shall be valid for the life of the contract. Alternates not selected at the time of award, but not identified as rejected may be selected within the time frame identified by the Contractor through the construction schedule where the selection will not impact the critical path and

Page 9: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

Food Court Station Asian Concept unc-4721Student Union Building ALTERNATESUniversity of Connecticut, Storrs, CT 012300 - 1

overall substantial completion of the contract. Should the Owner wish to exercise executing an Alternate after the last date reflected within the CPM Construction schedule for selection of an Alternate, the Alternate(s) may be negotiated as applicable, in accordance with the requirements associated with a Proposed Change Order.

PART 2 - PRODUCTS (Not Used)

PART 3 - EXECUTION

3.1 SCHEDULE OF ALTERNATES

A. Deduct Alternate No. 1: Foodservice Equipment Scope Removal.

1. Base Bid: Provide all foodservice equipment as indicated on FS-101.2. Alternate: Change the following items on the foodservice schedule to Owner Furnished

and Contractor Installed:a. Item 6 - Steamerb. Item 25 - Warming Cabinetc. Item 34 - Ice Cuberd. Item 41 - Dishwasher

END OF SECTION 012300

Page 10: TIME: 2:00 p.m. PROJECT: Student Union Project Number: 300106 … DOCUMENTS/300106-RFP... · 1) Attached is the Pre Bid Meeting Sign In Sheet 2) Attached is Addendum #1 from edm 3)

UNIVERSITY OF CONNECTICUT STUDENT UNION – QSR DINING BUILDOUT PROJECT NUMBER: 300106 FORM OF PROPOSAL

Page 8 of 23 Contractor’s Initials:________

E. SCHEDULE OF ALTERNATES: Revised 5/1/19 Provide Alternate Prices which reflect the work of the bid package under which this bid proposal was submitted and shall remain valid for the life of the project and include all costs for a complete installation. All pricing is inclusive of all costs of wages, applicable taxes, benefits, and applicable insurance. The Prices herein shall remain valid for the life of the project and include all costs for a complete installation.

A. Deduct Alternate #1 – Foodservice Equipment Scope Removal

1. Base Bid: Provide all foodservice equipment as indicated on FS-101 2. Alternate: Change the following items on the foodservice schedule to Owner Furnished and

Contractor Installed; a. Item 6 – Steamer b. Item 25 – Warming Cabinet c. Item 34 – Ice Cuber d. Item 41 – Dishwasher

DEDUCT $_________________________

END OF ALTERNATES