4
Thermo Scientific™ AquaSensors DataStick measurement system for universal plug & play. Markets/Applications • Wastewater treatment • Metal finishing (chrome/cyanide destruct) • Bleaching pulp • Disinfection control Product Specifications PROCESS WATER ANALYSIS Thermo Scientific AquaSensors DataStick ORP measurement system Thermo Scientific™ AquaSensors ORP DataStick™ • Differential ORP measurement • Pre-calibrated (no field calibration required) • Plug & play sensor heads • Replaceable quad junction salt bridges • Electrode protection options • Offered in a variety of materials • Direct data reporting (24-bit) • Plug & play industrial communications adapters Connect this ORP sensor directly to a PLC (Programmable Logic Controller) for seamless integration with industrial control systems. Use any computer to display data, calibrate and customize the measurement without an intermediate analyzer electronics box. Sensor heads are pre-calibrated and can be replaced or exchanged with any other type of sensor without taking the system down. Save space, time and money.

Thermo Scientific AquaSensors DataStick

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Thermo Scientific™ AquaSensors DataStick measurement system for universal plug & play.

Markets/Applications

• Wastewatertreatment

• Metalfinishing(chrome/cyanidedestruct)

• Bleachingpulp

• Disinfectioncontrol

Pro

du

ct Sp

ecification

sP R O C E S S W A T E R A N A L Y S I S

Thermo Scientific AquaSensors DataStick ORP measurement system

Thermo Scientific™ AquaSensors ORP DataStick™

• DifferentialORPmeasurement

• Pre-calibrated(nofieldcalibrationrequired)

• Plug&playsensorheads

• Replaceablequadjunctionsaltbridges

• Electrodeprotectionoptions

• Offeredinavarietyofmaterials

• Directdatareporting(24-bit)

• Plug&playindustrialcommunicationsadapters

ConnectthisORPsensordirectlytoaPLC(ProgrammableLogicController)forseamlessintegrationwithindustrialcontrolsystems.Useanycomputertodisplaydata,calibrateandcustomizethemeasurementwithoutanintermediateanalyzerelectronicsbox.Sensorheadsarepre-calibratedandcanbereplacedorexchangedwithanyothertypeofsensorwithouttakingthesystemdown.Savespace,timeandmoney.

2 Engineering Specifications

1.TheORPsensorshallbeofDifferentialElectrodeTechniquedesignusingtwoelectrodestocomparetheprocessvaluetoastableinternalreferencesolution.Thestandardelectrodeshallhavenon-flowingandfouling-resistantcharacteristics.

2.Thesensorshallhavehex-shapedwrenchflatstofacilitatemounting,andshallbeconstructedofamaterialwithexceptionalchemicalresistanceandmechanicalstrength.Thismaterialshallenablethesensortobeinstalledinmetalfittingswithoutleakageusuallycausedbyheatingandcoolingcycleswhendissimilarmaterialsarethreadedtogether.

3.Thesensorshallhaveinterchangeable,pre-calibratedplug-insensorheadsandcommunicationsadaptersthatcanbeinstalledwithoutpoweringdownthesystem.

4.Thesensorshallhave1inchNPTthreadsonbothendstomountintoastandard1inchpipetee,a1.5inchunionmounting,orimmersionhardware.

5.Thebuilt-inelectronicsofthesensorshallbecompletelyencapsulatedandO-ringsealedforprotectionfrommoistureandhumidity.

6.Thesensorshallhaveabuilt-inpre-amplifier,universalsignalconditioningelectronics,universalengineering

unitsconversion,andinteractivecommunicationswithahostcomputerordisplayinterfaceusingoneofseveralprotocolsincludingModbus®RTU,DeviceNet™,PROFIBUS™,USB,CANopenorEthernet.

7.Thesensorshallhaveanintegraltemperaturesensortomeasuretemperatureindependently.

8.Thesensorshallincludeatitaniumgroundelectrode(standard)toeliminategroundloopcurrentsinthemeasuringelectrode.

9.ThesensorshallbeThermoScientificAquaSensorsORPDataStick.

Thermo Scientific DataStick Analytical System

DataStickProvidesuniversalconversionofsensorsignalsandinteractivecommunicationsformeasurement,calibration,configurationanddiagnostics.

Communications AdapterPlugsintotheDataSticktoprovidepoweranddirectinteractivecommunicationswithcontrolsystems.

Differential ORP Sensor HeadPre-calibratedforORPandtemperature.CanbepluggedintoanyDataSticktoyieldaccurate24-bitdata.

AV38 Local Display/Controller2linedisplayand7keynavigation.Datareportingwithupto2currentoutputs.2FormCrelays.Digitalcommunications.

Key Components

Interchangeable Communication Adapters

Interchangeable Sensor Heads

Universal Sensor Module

3Thermo Scientific AquaSensors ORP DataStick

Providesuniversalconversionofsensorsignalsandinteractivecommunicationsformeasurement,calibration,configurationanddiagnostics.Mountingadapters,junctionboxesandrechargekitsareavailable.

1 Inch Tee Mounting

1.5 Inch Union Mounting

1.5 Inch Ball Valve

Sanitary Mount

Hand Rail Mounting Assembly 1 Inch Immersion Mounting

with Junction Box (7 foot extension is standard)

Specifications

MeasurementSystemPerformance†

Range: -2100mVto+2100mVResolution:0.1mVAccuracy:0.1%ofreadingStep Response Time:90%in30seconds

OperationalEnvironment

PEEK Sensor HeadTemperature Range:-5ºCto95ºCMaximum Pressure:100psig@95ºCMaximum Flow Rate:10ft/second

CPVC Sensor HeadTemperature Range:-5ºCto75ºCMaximum Pressure: 85psig@75ºCMaximum Flow Rate:10ft/second

Power Requirements‡

Voltage Range:10to30VDCMaximum Power:200mWTypical Power:120mW

Construction

Process Electrodes:PlatinumorgoldGround Rod:Titanium(standard),316stainlesssteelorHastelloy®CO-rings:Viton®(othermaterialsavailable)

Sensor Head Material:PEEKorCPVCDataStick Material:316stainlesssteel,PEEK,orCPVCWeight:1.2lbs(PEEKorCPVC);2.6lbs(316stainlesssteel)

Units Of Measure Measurement Units:mVTemperature Units:ºC,ºF

Calibration†† Sample:1pointTemperature:1point

Temperature Compensation Options‡‡

Temperaturemeasurementisprovidedasanindependentmeasurement.

Other Configuration Options

Sensor Filter:0to100secondsTemperature Filter:0to100seconds

Approvals And Ratings

Immunity & Emissions:CEcertified89/336/EEC:CISPER11,EN61000(-4-2,-4-3,-4-4,-4-6,4-8)Safety:cULuslisted;367GE303570Hazardous Locations:HazLocClass1,Division2,GroupsA,B,C,D.Maxambient80ºC

†Note:Typicalat25°Cperformanceunaffectedbycablelength‡Note:ClassIIDCpowersupplyrequired††Note:ORPandtemperaturearepre-calibratedatthefactory‡‡Note:Temperaturecanbeenteredmanually

Pro

du

ct Sp

ecification

s

ORP DataStick Ordering Information

Part No. Description

DS-b-t DataStick

Body Material (b)

1 =316stainlesssteel2 =CPVC3 =PEEK

Mounting (t)

1 =NPTfront/back2 =1inchNPTfrontonly3 =1.5ballvalveinsertion4 =2inchtri-clamp5 =2.5inchtri-clamp

ORP-b-t-x-y-z-r ORP Sensor Head

Body Material (b) 2 =CPVC3 =PEEK

Electrode Type (t) 1 =Platinum2 =Gold

Sensor (x) A =ProtectedB =Processflat

Filling Solution (y) 1 =Standard

Salt Bridge (z) A =Standard

Ground Rod (r)

1 =316stainlesssteel2 =Titanium(standard)3 =HastelloyC

CA-b-nw-x-y Communications Adapter

Body Material (b) 1 =316stainlesssteel2 =CPVC3 =PEEK

Accessories Ordering Information

Part No. Description

Local Display Controller Interface

AV38 ¼DIN,outputs,relays,digitalcommunicationsoptions

Salt Bridge Replacements

SBS01 PEEKprotected

SBS02 PEEKprocessflat

SBS03 CPVCprotected

SBS04 CPVCprocessflat

SBC01 Storagecapwithsponge

ORP Solutions—500 mL Bottles

RCS04 ORPStoragesolution

RCS01 Standardcellsolution

ORPSOL200 200mVCalibration

Mounting Hardware

MH3022 1inchteemounting,CPVC

MH3011 1inchteemounting,316SS

MH1042 1.5inchteemounting,CPVC

MH1041 1.5inchteemounting,316SS

MH1112 1.5inchballvalve,CPVC,lowpressure

MH1111 1.5inchballvalve,316SS,lowpressure

MH1122 1.5inchballvalve,CPVC,highpressure

MH1121 1.5inchballvalve,316SS,highpressure

MH1242 Handrailmountingassembly,swivel/immersion,PVC

MH3083 1inchimmersionmountingwithjunctionbox,PVC(7footextensionisstandard)

Consultfactoryforotheravailablesensormountingoptions.

Thermo Scientific AquaSensors ORP DataStick

• Global support—withexperiencethatcomesfromsupportingourcustomersforover35yearsthroughouttheworld,ourwaterqualityspecialistsandcustomersupportteamsofferaquick,thoroughandprofessionalresponsetoanyproblemencountered.

•Focus on user benefits—weworkcloselywithyoutodefineyourneeds,andensureyouareusingthemonitorinawaythatimprovesyourbottomline.Formoreinformation,contactyourlocalwaterqualityspecialistsorvisit:www.thermoscientific.com/processwater.

Communications (nw)

1A =RS232ASCII2B =ModbusRTU2A =ModbusRS2324B =CANopen7R =Ethernet5R =DeviceNet8R =USB

Cable Length (x)

1 =10feet2 =20feet3 =30feet

Cable Termination (y)

A =Strippedwires

North America Toll Free: 1-800-225-1480 Tel: 1-978-232-6000 [email protected]

NetherlandsTel: (31) 033-2463887 [email protected]

ChinaTel: (86) 21-68654588 [email protected]

India Tel: (91) [email protected]

Singapore Tel: (65) [email protected]

Japan Tel: (81) [email protected]

Australia Tel: (613) 9757-4300in Australia (1300) [email protected]

Water Analysis Instruments

S-ASDSORP-E0113RevB

©2013ThermoFisherScientificInc.Allrightsreserved.ModbusisaregisteredtrademarkofSchneiderElectric.DeviceNetisatrademarkofODVA.PROFIBUSisatrademarkofPROFIBUSNutzerorganisatione.V.HastelloyisaregisteredtrademarkofHaynesInternational,Inc.VitonisaregisteredtrademarkofE.I.DuPontDeNemours&Company.AllothertrademarksarethepropertyofThermoFisherScientificInc.anditssubsidiaries.

Thermo Fisher ScientificWater Analysis InstrumentsChelmsford, MA USAQuality Management SystemRegistered to ISO 9001

thermoscientific.com/processwater