168
FIREBREAK DOORS TECHNICAL CATALOGUE MECOSA

Thecnical Catalog 2011 (English)

Embed Size (px)

Citation preview

FIREBREAK DOORS

TECHNICAL CATALOGUE

MECOSA

FIREBREAK DOORS SISTEMS

MECOSA

1. COMPANY PROFIL

- Profil MECOSA group .

- Aprovals.

- References - Instalations

2. PRODUCTS

01 - Sliding doors 02 - Guillotines 03 - Glass doors 04 - Overhead doors 05 - Roll-up doors 06 - Curtains 07 - Sectional doors 08 - Fortex, Pavermec & Big dimensions swing doors 09 - Swing doors 10 - Engines 11 - Panels 12 - Accessories

MECOSA

COMPANY PROFIL

- Profil MECOSA Group

MECOSA is born in 1984, realizing all kinds of closings of Metallic doors. Later, due to a social worry of Market in fight against the fire, MECOSA offers a service for his clients of any diversity of doors firebreak, already be supplying or making doors of special measures. The application with rigor of the regulation that monitors for the rights fundamental of the citizens, it has reverberated in the restructuring Of our company her specializing in the area of passive protection firebreak. Of the above mentioned specialization, the companies are born Gratings and Cross-bows Mecosa S.L., Industrial doors PROIND S.L. and AICON ANOIA S.L. forming the group MECOSA which is integrated by an equipment of 70 professionals, and It possesses a space to large of 3000 m2 to develop his activities. MECOSA, leading company in manufacture and installation of passive protection firebreak, it offers a diversity of such services as: · Engineering department in the protection area firebreak. · Studies and accomplishments of safety projects firebreak. · Advice for clients. · constructive Solutions in the execution of a work. · Supply and installation for the passive safety firebreak. · Certification of realized facilities. · Service contracts of firebreak doors. MECOSA offers a FULL SERVICE IN THE FIGHT COUNTER FIRE

WELLCOME TO MECOSA

MECOSA

COMPANY PROFIL

- APROVALS

APROVALS TABLE

Sliding 1H

Sliding 2H

Sliding of glass

Swing of glass

Window fixes

Sliding 1H

Sliding 1H

Sliding 1H

Guillotines

Telescopic 3L c/pedestrian

Rooll-up doors

Swing door

Sectional 1L

Sectional 1L

Rooll-up doors

Rooll-up doors

Rooll-up doors

Telescopic 3L c/pedestrian

Guillotines

Guillotines

Guillotines

APROVALS TABLE

SWING 1L

SWING 1L

SWING 1L WHITH Spyhole

SWING 2L

SWING 2L

SWING 2L WHITH Spyhole

SWING 1L SP 53,5mm

SWING 2L SP 63,5mm

SWING 2L SP 63,5mm WHITH

Spyhole 400x600

SWING 2L SP 63,5mm

Textile CURTAIN

Textile CURTAIN

Cooling water down

TYPE MODEL EI2 LABORATORY Nº CERTIFYCATE

TYPE MODEL KID DB. LABORATORY Nº CERTIFYCATE

TYPE MODEL RESIST. LABORATORY Nº CERTIFYCATE

MECOSA

COMPANY PROFIL

- References - Instalations

MECOSA is conscious the importance of the different systems to firebreak doors in sectors like, Distribution, Health, Hotel and catering business restoration, Trade Centers, Offices, Parkings, etc. The experience and the knowledge of the markets are two factors that they have contributed to that MECOSA, is the best choice. To local level our knowledge across our collaborators in the mentioned ones sectors have allowed us to establish good relations with clients that value the manufacture, agility and MECOSA's reliability. From 2008, MECOSA began the international experience in different countries. The narrow collaboration with our collaborators / clients they give us several key factors that are decisive for the correct functioning of the systems of firebreak doors, we name these factors applied experiences what indicates the aptitude to identify better solution for every client. Later we relate some of our facilities :

DISTRIBUITION: HEALT:

CONSUM: MANY INSTALATIONS

ALCAMPO: MANY INSTALATIONS

CAPRABO: MANY INSTALATIONS

DECATHLON: MANY INSTALATIONS

LIDL: MANY INSTALATIONS

MERCADONA-: MANY INSTALATIONS

IKEA: MANY INSTALATIONS

EROSKI: MANY INSTALATIONS

CARREFOUR: MANY INSTALATIONS

HOSPITAL DE SAN PABLO- BCN

HOSPITAL BELLVITGE- BCN

HOSPITAL SANTA TECLA- TARRAGONA

BIOMEDICAL CENTER- BCN

HOSPITAL MATARO- BCN

HOSPITAL INFANTIL- VALENCIA

HOSPITAL SON DURETA- MALLORCA

SINCROTON SANT CUGAT- BCN

HOSPITAL SANT JOAN D

ESPI- BCN

TRANSPORTS: TRADE CENTERS:

ZAL TO BARCELONA

PORT OF BARCELONA

BARCELONA AIRPORT

ALICANTE AIRPORT

MALAGA AIRPORT

PALMA DE MALLORCA AIRPORT

LAS PALMAS CANARIAS AIRPORT

AVE MALAGA

SUBWAY DE BARCELONA

TRANSMEDITERRANEA-BCN

RENFE- AVE BARCELONA

MADRID T-4 AIRPORT

T. C. LA CORUÑA

T. C. ARANJUEZ- MADRID

T. C. EL EJIDO- ALMERIA

T. C. ELCHE- ALICANTE

T. C. MONTIGALA- BCN

T. C. LA MAQUINISTA- BCN

T.C. LA ILLA- BCN

T. C. GRAN VIA- BCN

T. C. LAS GLORIAS- BCN

WORLD TRADE C.- BCN

T. C. LANZAROTE

WALA-BCN

VILLAMARINA VILADECANS- BCN

ANEC BLAU CASTELLDEFELS- BCN

CULTURE: OFICCES:

BARCELONA UNIVERSITY - MANY

PALACE OF THE MUSIC TO BARCELONA

MUSEUM MACBA – BCN

PLANETARIUM- BCN

CONFERENCE HALL - BCN

PEDRALBES PALACE - BCN

THEATER GRANOLLERS- BCN

THEATER GOYA- BCN

THEATER BADALONA

THEATER MONTMELO

THEATER ABRERA

CAMPSA- OFFICES

SEAT-MANY

FECSA-ENDESA: OFFICES

MEDIA – MARKt: MANY

TV3-BCN

WORLD TRADE CENTER- BCN

COPISA- BCN

HOTEL: OTHERS:

HOTELS RAFAEL- MANY

HOTEL 22 @- BCN

HOTELES HESPERIA

HOTELES HUSA

HOTEL FRONTAIR

HOTEL MANDARIN

HOTEL ARTS

PALAU SANT JORDI- BCN

CITROEN

NESTLE

HENKEL

ALMIRALL LABORATORY

TUNELS DE GUADARRAMA-MADRID

SWIMM CLUB TO BARCELONA

SWIMM CLUB TOSABADELL

ESTADIUM FC BARCELONA

BASQUET BADALONA

MARKET TOSANT BOI- BCN

MARKET TO TERRASSA- BCN

MARKET TO STA. COLOMA- BCN

HONDA

LABORATORY DERMOFARM

PORT AVENTURA

EXPORTATION:

ANDORRA

HOLLAND

LATVIA

PORTUGAL

MECOSA

PRODUCT

01 – SLIDING DOORS

01-1

(MOBILE PARTITIONS) FIREBREAK SLIDING DOORS

1 LEAF

TELESCÓPIC

01-2

The sliding firebreak doors are designed for the closing and sectorisation of hollows of great dimensions, as much in the always opened position, as in intensive use. Its operation can be manual, semiautomatic and automatic. Closing guaranteed by a counterbalance that work on the leaf (*). When the alarm signal emits an impulse to the electromagnet (24 VCC) or the thermal fuse reaches the temperature of 68º C the door is released and is dragged by the counterbalance, being the door totally closed and with the action of the fire expands the intumescing meeting installed in the smoke-cutting labyrinth in all the perimeter of the door, being this sealed.

Superior guide of suspension of high quality and durability made with galvanized material, of three different measures following the weight and measurement from the door. Installed according to the characteristics of the hollow. Roller mounted on balls bearings.

Each leaf is constructed with two steel plates (0.6/0.8 mm of thickness) training panels of 1150 mm, stuffed of HD rock wool of 145 Kg./m3 closed by its borders by a special profile in Or of 3 mm of thickness. Handle inlaid with gunner. Conduction by the part inferior by means of an hidden skate inside the profile. Counterbalance together with by means of cables of steel the electromagnet with disconnection pulse to allow opening and to close manual, or thermal fuse. The operation of the semiautomatic or automatic door in consists of engine, electronic control panel, pulses of opening, closes, photocell and all the necessary elements for a complete installation. firebreak doors MECOSA fulfills the effective norm and for it we certified by means of tests in official laboratories in each of its different versions, its application this legislated in different decrees from prevention of fire NORM UNE 23802 (NBE CPI/96) and UNE EN 1634-1

SLIDING DOORS DESCRIPTION

FIRE RESISTENCE EI2 / 60-90-120-180-240 MINUTES

OPERATION

GUIDE

LEAF

(*) In automatic mode, the closing is secured by a UPS. 01-3

STANDARD EQUIPMENT: Support of guides for anchorage in wall or forged Electromagnet or thermal fuse Drawer of counterbalance. Pre-lacquered steel panel. Position of the always opened door. U galvanized peripheral. Drawer galvanized bedspread

SINGLE LEAF SLIDING DOOR

DOUBLE LEAF SLIDING DOOR

MULTIPLE LEAVES TELESCOPIC SLIDING DOOR

Speed governor – maintains constant closing Shock absorber of impact - the closing cushions and fits. Electromagnet - retaining electrical of 24 VCC 1155 thermal Fuse UNE C - retaining thermal until 68ºC engine - automatic or semiautomatic Pedestrian door - enrolled in the leaf track Guide covers Counterbalance opposed to the closing post Support of guide according to constructive design Finished in stainless steel Lock Door in intensive

ACCESORIES

01-4

COLD STORAGE FIREBREAK DOORS EI2 60

SWING DOOR

SLIDING DOOR

01-10

Cold storage firebreak doors, for industrial line of application for refrigerator chambers of conservation and freezing for minimum temperatures of - 20º C and outer difference of +/- 50º C constructed in stainless steel AISI 304 with a fire RESISTENCE of 60 minutes. The leaf this made with panel multi-layer sandwich made up of onjected polyurethane of density 50 free Kg./m3 of CFC and HCFC, rock wool of 175 density Kg./m3 and calcic silicate plates with a total thickness of 120 mm. Outer the inner finished one/: Steel plate of 0.8 mm finished lacquer “white Pyrenean”, PVC or steel stainless AISI 304. Reinforcements: Lateral steel protections stainless AISI 304 of 2mm. Refrigerating draft excluder: Double profile of Watertightness in mounted compact EPDM on support of PVC under pressure governed. Profile inferior: For conservation door: profile stainless of 2 mm. For freezing door profile of 2 mm with inner conduction and lateral registries for the reheated one with 40 electrical RESISTENCE of W/ml. and 220 VAC. Unions fire-guards: Stainless Mounted borders in all the perimeter of the leaf. Ironworks: Outer gunner and inner type handle. (in the beating door the inner gunner is embedded.) Support of the rail: In steel profile stainless. of 5 mm. Rail: Rectangular massive aluminum border 40 x 15 mm with bearings of polyamide ball of 60 mm of diameter.

LEAF

RAIL

OPERATION

ACCESORIES

Engine Stainless steel ironworks. Protection bar on swinging doors

DESCRIPTION OF COLD STORAGE FIREBREAK DOORS EI2 60

01-11

COLD STORAGE SWING DOOR EI2 60

COLD STORAGE SLIDING DOOR EI2 60

COLD STORAGE SLIDING DOOR E 120; I2 120

01-15

02-1

MECOSA

PRODUCTS

02 – GUILLOTINES

GUILLOTINES FIREBREAK DOORS

MULTIPLE LEAVES

(CURTAIN FIREBREAK)

02-2

GUILLOTINE DOOR DESCRIPTION

The guillotine firebreak doors are designed for the closing and sectorisation of hollows of great dimensions, also in the opened position, and in intensive use. Its operation can be automatic manual or. Closing guaranteed by a counterbalance that work on the leaf (*). When the alarm signal emits an impulse to the electromagnet (24 VCC) or the thermal fuse reaches the temperature of 68º C the door is released and is dragged by the counterbalance, being the door totally closed and with the action of the fire expands the intumescences joint installed in the labyrinth smoke-cutter in all the perimeter of the door, being this sealed.

OPERATION

GUIDES Lateral guides of sliding of high quality and steel durability galvanized, installed according to the characteristics of the hollow, bearing with bearings to balls in the guidance, parachute of security..

GUIDE BEARING PARACHUTES

Each leaf this constructed with two steel plates pre-lacquered (0.6/0.8 mm of thickness) training panels of 1150 mm in rock stuffed wool width of HD of 145 Kg./m3 closed by its borders by a special profile in Or of 3 mm of thickness. Handle inlaid with gunner. Counterbalance together with by means of cables of steel the parachute and electromagnet to allow opening and to close manual, or thermal fuse. Following the height of the threshold the doors can be of 1 to 5 leaves. The operation of the door in automatic consists of engine, electronic control panel, pulses of opening, closes, necessary photocell, UPS and all the elements for a complete installation. firebreak doors MECOSA fulfills the effective norm and for it we certified by means of tests in official laboratories in each of its different versions, its application this legislated in different decrees from prevention of fire NORM UNE 23802 (NBE CPI/96) and UNE EN 1634-1

LEAF

(*) In automatic mode, the closing is secured by a UPS

FIRE RESISTENCE EI2 / 60-90-120-180-240 MINUTES

02-3

SINGLE LEAF GUILLOTINE DOOR

DOUBLE LEAVES GUILLOTINE DOOR

GUILLOTINE-CURTAIN DOOR BIG SIZE OR NUMBER OR LEAVES

STANDARD EQUIPMENT: Parachute of security Support of guides for anchorage in forged wall or. Electromagnet or thermal fuse Drawer of counterbalance. Pre-lacquered panel. Position of the always opened door.

Shock absorber of impact - the closing cushions and fits. Speed governor - Electromagnet maintains a constant speed - retaining electrical of 24 VCC UNE EC 1155 thermal Fuse - retaining thermal until 68ºC engine - automatic Pedestrian door - enrolled in the leaf track. Support of guide according to constructive design Finished in stainless steel Door in intensive use.

ACCESORIES

02-4

MECOSA

PRODUCTS

03 - GLASS

03-1

AUTOMATIC SLIDING DOORS EI2 60

1 / 2 LEAVES

03-2

AUTOMATIC SLIDING DOORS EI2 60 MEC-GLAS SISTEM

The automated glass firebreak doors are designed to close and to sectorize hollows in which the design and the treatment to the luminosity, have relevance. They are realized in 1 and 2 leaves of step, in which the pedestrian step and its intensive use are necessary, its transparency causes that the door happens unnoticed. When a fire signal takes place on the control unit, the door is totally closed, and with the action of the fire the joint installed in the labyrinth expands to isolate the smoke in all the perimeter of the door, being been this sealed. Its operation is always automatic, engineized with a reducing engine, control unit, battery, photocell, selector of positions, transformer, drive belt, two guides, double game of wheels on bearings. The reducing engine is single-phase, feeding of 240 V 50/60 Hertz., exit of feeding 24 VDC (500mA).

OPERATION

GUIDE

LEAF

Guide superior of suspension of high quality and RESISTENCE made with galvanized material, to roller mounted on bearings to balls, back-to-back the guide superior chassis-guides of the automatism for drag the same.

Leaf with peripheral frame in steel profiles, with stuffed of non-flammable material, the measures principles by leaf are 1500 x 2400 mm Finished galvanized, stainless steel options (ASI 304/316) or standard RAL lacquered to define.

FIRE RESISTENCE EI2 60 MINUTES

Multilaminate glass with isolating interleaves (gel) resistant to fire EI2 60 of +/- 23 mm of total thickness. In case the door this in contact with solar light (outer) glass must have a special protection giving a thickness increased in +/- 12 mm. When it receives the outer light without sun the thickness increased in +/- 4 mm.

GLASS

03-3

GLASS SWING DOORS EI2

1 / 2 LEAVES

03-6

GLASS SWING DOORS EI2 MEC-GLAS SISTEM

Firebreak doors beating of glass is designed to close and to sectorize hollow in which the design and the treatment to the luminosity, have relevance, are realized in 1 and 2 leaves of step, in which the pedestrian step and its intensive use are necessary, its transparency causes that the door happens unnoticed., Its operation is manual or automatic, in the case of manual it accedes by handles fire-guards and it is closed by door closer guaranteeing its closing, in the case of automatic works with an electromechanical engine (240 feeding of V 50/60 Hertz., exit of feeding 24 VDC, with a wharf and control unit of return. In case of lack of electrical fluid door closer work like a normal wharf, guaranteeing always its closing. the door is totally closed, and with the action of the fire the joint installed in the smoke isolation labyrinth in all the perimeter of the door.

OPERATION

FRAME

LEAF

The frame this made with galvanized, stuffed steel tube with non-flammable material and hinges in stainless steel.

FIRE RESISTENCE EI2 60-90 MINUTES

GLASS Multilaminated glass with interleaves (gel) resistant to fire EI2 60 of +/- 23 mm, EI2 90 of +/- 41 mm In case the door this in contact with solar light (outer) glass must have a special protection giving a greater thickness to the glass of +/- 12 mm. When it receives outer light without sun the thickness increased in +/- 4 mm.

Leaf with peripheral frame made in galvanized, stuffed steel with non-flammable material. The measures principles by leaf are 1500 x 2400 mm Finished galvanized, other options in stainless steel (ASI 304/316) or lacquered RAL standard to define.

03-7

GLASS FIXED FIREWALLS EI2

03-11

GLASS FIXED FIREWALLS EI2 MEC-GLAS SISTEM

The fixed glass firewall, complete the closure and segmentation of spaces, giving a possibility of transparency in the traditional walls of sectors, remaining unnoticed.

OPERATION

FRAME

GLASS

The frame is made of galvanized steel tube filled with fireproof material. Galvanized finish, stainless steel alternatives (ASI 304/316) or standard RAL painted to define.

Multilaminated glass interlayered with isolating (gel) EI 60 fire-resistant of + / - 23 mm, EI 90, + / - 41 mm. and EI 120, + / - 52 mm. total thickness. In the event that the door is in contact with sunlight (outer) glass has to be given special protection to the glass thickness greater than + / - 12 mm, When you get outside without sun light increases the thickness by + / - 4mm,

FIRE RESISTENCE EI2 60-90-120 MINUTES

03-12

Glass from 0 a 1499 mm. witch 1 Pieces Glass from 1500 a 2999 mm. witch 2 Pieces Glass from 3000 a 4499 mm. witch 3 Pieces Glass from 4500 a 6000 mm. witch 4 Pieces

STANDARD WIDTH GLASS PARTITION

AUTOMATIC DOUBLE LEAVES SLIDING FIREBREAK DOOR

AUTOMATIC SINGLE LEAF SLIDING FIREBREAK DOOR

SWING FIREBREAK DOOR 1 O 2 LEAVES WITH FIXED PARTS

03-15

EI 30 Fire resistence 30 minutes

Interbedded with plywood Glass intumescent, fire-resistant glass composite

Thickness

Technical Data

Dimension tolerance * Thickness tolerance Weight Light Transmission

Soundproofing Rw (C, Ctr) Coef.Ug Impact resistence 08-301/EN NFP 12600

Identifying marks

*+/-2mm. Until an edge lenght of 2 meter. +/-3mm. An edge lenghr of 2 meter.

Tip A protective aluminium tape is applied arround the entire circunference to the glass.

Peripherical adhesive for aluminium

The protective strip of aluminium should not be lfted or damaged. Otherwise, it could alter the properties of the material.

Do not put preassure on the volume during assembly.

The volumes should be stored vertically on the side of an angle larger than 6 degrees.

Volumes stored must be protected from UV rays, rain and moisture.

INDOOR USE The quality interior glass should not be used in a place where they can be directly exposed to ultraviolet rays.

REQUIEREMENT OF THE CLASSIFICATION OF FIRE ONLY IF YOU CAN MEET THE PANELS INSTALLED ACCORDING TO THE INSTRUCTIONS LISTED IN THE MINUTES AND AGREEMENTS WITH NO MODIFICATION.

YOU MUST ENSURE THET THE PRODUCTS FIT FOR A PARTICULAR PURPOSE AND THAT MEETS THE STANDARDS LOCALS AND NATIONAL REGULATIONS

Document not contract

EI 30 Fire resistence 30 minutes

Interbedded with plywood Glass intumescent, fire-resistant glass composite

Thickness

Technical Data

Dimension tolerance * Thickness tolerance Weight Light Transmission

Soundproofing Rw (C, Ctr) Coef.Ug Impact resistence 08-301/EN NFP 12600

Identifying marks

*+/-2mm. Until an edge lenght of 2 meter. +/-3mm. An edge lenghr of 2 meter.

Tip A protective aluminium tape is applied arround the entire circunference to the glass.

Peripherical adhesive for aluminium

The protective strip of aluminium should not be lfted or damaged. Otherwise, it could alter the properties of the material.

Do not put preassure on the volume during assembly.

The volumes should be stored vertically on the side of an angle larger than 6 degrees.

Volumes stored must be protected from UV rays, rain and moisture.

UTILIZATION IN INTERIORS / EXTERIOR In case they are in use in exteriors, it must respect the sense of placement. East is indicated by means of a label placed in the glass.

REQUIEREMENT OF THE CLASSIFICATION OF FIRE ONLY IF YOU CAN MEET THE PANELS INSTALLED ACCORDING TO THE INSTRUCTIONS LISTED IN THE MINUTES AND AGREEMENTS WITH NO MODIFICATION.

YOU MUST ENSURE THET THE PRODUCTS FIT FOR A PARTICULAR PURPOSE AND THAT MEETS THE STANDARDS LOCALS AND NATIONAL REGULATIONS

Document not contract

Insert Anti-UV

EI 60 Fire resistence 60 minutes

Interbedded with plywood Glass intumescent, fire-resistant glass composite

Thickness

Technical Data

Dimension tolerance * Thickness tolerance Weight Light Transmission

Soundproofing Rw (C, Ctr) Coef.Ug Impact resistence 08-301/EN NFP 12600

Identifying marks

*+/-2mm. Until an edge lenght of 2 meter. +/-3mm. An edge lenghr of 2 meter.

Tip A protective aluminium tape is applied arround the entire circunference to the glass.

Peripherical adhesive for aluminium

The protective strip of aluminium should not be lfted or damaged. Otherwise, it could alter the properties of the material.

Do not put preassure on the volume during assembly.

The volumes should be stored vertically on the side of an angle larger than 6 degrees.

Volumes stored must be protected from UV rays, rain and moisture.

INDOOR USE The quality interior glass should not be used in a place where they can be directly exposed to ultraviolet rays.

REQUIEREMENT OF THE CLASSIFICATION OF FIRE ONLY IF YOU CAN MEET THE PANELS INSTALLED ACCORDING TO THE INSTRUCTIONS LISTED IN THE MINUTES AND AGREEMENTS WITH NO MODIFICATION.

YOU MUST ENSURE THET THE PRODUCTS FIT FOR A PARTICULAR PURPOSE AND THAT MEETS THE STANDARDS LOCALS AND NATIONAL REGULATIONS

Document not contract

EI 60 Fire resistence 60 minutes

Interbedded with plywood Glass intumescent, fire-resistant glass composite

Thickness

Technical Data

Dimension tolerance * Thickness tolerance Weight Light Transmission Soundproofing Rw (C, Ctr) Coef.Ug

Impact resistence 08-301/EN NFP 12600

Identifying marks

*+/-2mm. Until an edge lenght of 2 meter. +/-3mm. An edge lenghr of 2 meter.

Tip A protective aluminium tape is applied arround the entire circunference to the glass.

Peripherical adhesive for aluminium

The protective strip of aluminium should not be lfted or damaged. Otherwise, it could alter the properties of the material.

Do not put preassure on the volume during assembly.

The volumes should be stored vertically on the side of an angle larger than 6 degrees.

Volumes stored must be protected from UV rays, rain and moisture.

UTILIZATION IN INTERIORS / EXTERIOR In case they are in use in exteriors, it must respect the sense of placement. East is indicated by means of a label placed in the glass.

REQUIEREMENT OF THE CLASSIFICATION OF FIRE ONLY IF YOU CAN MEET THE PANELS INSTALLED ACCORDING TO THE INSTRUCTIONS LISTED IN THE MINUTES AND AGREEMENTS WITH NO MODIFICATION.

YOU MUST ENSURE THET THE PRODUCTS FIT FOR A PARTICULAR PURPOSE AND THAT MEETS THE STANDARDS LOCALS AND NATIONAL REGULATIONS

Document not contract

Insert Anti-UV

EI 90 Fire resistence 90 minutes

Interbedded with plywood Glass intumescent, fire-resistant glass composite

Thickness

Technical Data

Dimension tolerance * Thickness tolerance Weight Light Transmission

Soundproofing Rw (C, Ctr) Coef.Ug Impact resistence 08-301/EN NFP 12600

Identifying marks

*+/-2mm. Until an edge lenght of 2 meter. +/-3mm. An edge lenghr of 2 meter.

Tip A protective aluminium tape is applied arround the entire circunference to the glass.

Peripherical adhesive for aluminium

The protective strip of aluminium should not be lfted or damaged. Otherwise, it could alter the properties of the material.

Do not put preassure on the volume during assembly.

The volumes should be stored vertically on the side of an angle larger than 6 degrees.

Volumes stored must be protected from UV rays, rain and moisture.

INDOOR USE The quality interior glass should not be used in a place where they can be directly exposed to ultraviolet rays.

REQUIEREMENT OF THE CLASSIFICATION OF FIRE ONLY IF YOU CAN MEET THE PANELS INSTALLED ACCORDING TO THE INSTRUCTIONS LISTED IN THE MINUTES AND AGREEMENTS WITH NO MODIFICATION.

YOU MUST ENSURE THET THE PRODUCTS FIT FOR A PARTICULAR PURPOSE AND THAT MEETS THE STANDARDS LOCALS AND NATIONAL REGULATIONS

Document not contract

EI 90 Fire resistence 90 minutes

Interbedded with plywood Glass intumescent, fire-resistant glass composite

Thickness

Technical Data

Dimension tolerance * Thickness tolerance

Weight Light Transmission Soundproofing Rw (C, Ctr) Coef.Ug Impact resistence 08-301/EN NFP 12600

Identifying marks

*+/-2mm. Until an edge lenght of 2 meter. +/-3mm. An edge lenghr of 2 meter.

Tip A protective aluminium tape is applied arround the entire circunference to the glass.

Peripherical adhesive for aluminium

The protective strip of aluminium should not be lfted or damaged. Otherwise, it could alter the properties of the material.

Do not put preassure on the volume during assembly.

The volumes should be stored vertically on the side of an angle larger than 6 degrees.

Volumes stored must be protected from UV rays, rain and moisture.

UTILIZATION IN INTERIORS / EXTERIOR In case they are in use in exteriors, it must respect the sense of placement. East is indicated by means of a label placed in the glass.

REQUIEREMENT OF THE CLASSIFICATION OF FIRE ONLY IF YOU CAN MEET THE PANELS INSTALLED ACCORDING TO THE INSTRUCTIONS LISTED IN THE MINUTES AND AGREEMENTS WITH NO MODIFICATION.

YOU MUST ENSURE THET THE PRODUCTS FIT FOR A PARTICULAR PURPOSE AND THAT MEETS THE STANDARDS LOCALS AND NATIONAL REGULATIONS

Document not contract

Insert Anti-UV

03-21

EI 120 Fire resistence 120 minutes

Insulating compound glass of: Glass multilaminated with interleavings intumescents,

Thickness

Technical Data

Dimension tolerance * Thickness tolerance Weight Light Transmission

Soundproofing Rw (C, Ctr) Coef.Ug Impact resistence 08-301/EN NFP 12600

Identifying marks

*+/-2mm. Until an edge lenght of 2 meter. +/-3mm. An edge lenghr of 2 meter.

Tip A protective aluminium tape is applied arround the entire circunference to the glass.

Peripherical adhesive for aluminium

The protective strip of aluminium should not be lfted or damaged. Otherwise, it could alter the properties of the material.

Do not put preassure on the volume during assembly.

The volumes should be stored vertically on the side of an angle larger than 6 degrees.

Volumes stored must be protected from UV rays, rain and moisture.

INDOOR USE The quality interior glass should not be used in a place where they can be directly exposed to ultraviolet rays.

REQUIEREMENT OF THE CLASSIFICATION OF FIRE ONLY IF YOU CAN MEET THE PANELS INSTALLED ACCORDING TO THE INSTRUCTIONS LISTED IN THE MINUTES AND AGREEMENTS WITH NO MODIFICATION.

YOU MUST ENSURE THET THE PRODUCTS FIT FOR A PARTICULAR PURPOSE AND THAT MEETS THE STANDARDS LOCALS AND NATIONAL REGULATIONS

Document not contract

fire-resistant, glass compasite Pilkington Glass of the range Pilkington

MECOSA

PRODUCTS

04- OVERHEAD DOORS

04-1

OVERHEAD DOOR EI2 30

04-2

OVERHEAD DOORS DESCRIPTION

OPERATION

FIRE RESISTENCE EI2 30 MINUTES

The firewall garage doors are designed for the closure and segmentation of large holes in both the position still open, as in heavy use. Its operation is automatic. When the alarm emits an electrical impulse to the table and the door is released and is pulled by the engine, leaving the door fully closed and the action of fire expands board installed in the maze intumescent smoke-cutter around the perimeter the door is being sealed. In case of lack of electricity, the electric locks the door with a UPS

LEAF

04-3 (*) Always necessary a safe power line or placing a UPS

GUIDE

Each leaf is built with two layers of pre-lacquered steel (0.6 / 0.8 mm thick) forming panels of 1150 mm wide tongue and groove, rock wool filling high density of 145 kg/m3 closed by its borders for a special U-border 3 mm thick. The top leaf is 1 / 3 the height and the bottom leaf in 2 / 3 parts. The operation of the automatic door consists of engine, electronic control box, buttons for opening, closing, photocell and all the elements necessary for a complete installation. The firebreak doors MECOSA comply with current regulations and to do so by laboratory tests certify officers in each of its different versions, your application is legislated in various fire prevention ordinances NORMA UNE 23802 (NBE CPI/96) and UNE EN 1634-1

Sliding side guides of high quality and durability of galvanized steel, installed according to the characteristics of the hole, bearing with ball bearings in the guide, safety parachute.

STANDARD EQUIPMENT: Support guidelines for anchoring to wall or wrought Panel pre-lacquered. Position the door always open. Security Parachute engine – Automatic.

Pedestrian Door - inscribed on the lower leaf Support directory as constructive design Door intensive Pedestrian Door - inscribed on the lower leaf Support directory as constructive design Door for intensive use

ACCESORIES

04-5

OVERHEAD DOOR 2 LEAVES EI2 30

OVERHEAD DOOR 2 LEAVES EI2 30

MECOSA

PRODUCTS

05 – ROLL-UP DOORS

05-1

ROLL-UP FIREBREAK DOORS

ROLL-UP DOOR EI

ROLL-UP DOOR E

05-2

ROLL-UP FIREBREAK DOORS Model MEC

The roll-up firebreak doors are designed for the closure and segmentation of large voids, both in position always open, as in heavy use. Its operation is like any electric roller door, engineized vertical opening, Direct gear engine shaft 380 v. frontal displacement without compensation spring, operated by latchkey or button, in case of fire or alarm the control unit sends an electrical signal to the mail box and this means the engine shuts the door. Leaving the door fully closed and the action of fire intumescent expands board installed in the guides and the periphery of the door being fully sealed. In case of lack of electricity, the electric panel issues an order to a 24 VCC auxiliary engine which through a built-in UPS shuts the door.

OPERATION

GUIDE

LEAF

SHAFT

The leaf is made up of slats with aluminum core with core insulation and insulation boards on both sides with a total thickness of 35 mm and a height of 80 mm, with isolating plates sealing, finishing leaf standard RAL painted stucco and colors selected order.

Made of galvanized material 2 mm thick, U-shaped pipe welded to a reinforcement and its interior is protected isolating joints built to prevent the chafing of the lames and total measures 95 x 140 mm.

The tubular shaft is 3.6 to 7.1 mm in thickness and diameter varies in the same widths of 101.6 to 323.9 mm., Coupled with the extreme engine through solid shaft with keyway on bearings for lateral supports to slide over and get a proper curl.

05-3

FIRE RESISTENCE EI2 60 MINUTES

ROLL-UP FIREBREAK DOOR MEC-IMPORT Model

The roll-up firebreak doors are designed for the closure and segmentation of large voids, both in position always open, as in heavy use. Its operation is like any electric roller door, engineized vertical opening, Direct gear engine shaft 380 v. frontal displacement without compensation spring, operated by latchkey or button, in case of fire or alarm the control unit sends an electrical signal to the mail box and this means the engine shuts the door. Leaving the door fully closed and the action of fire intumescent expands board installed in the guides and the periphery of the door being fully sealed. In case of lack of electricity, the electric panel issues an order to a 24 VDC auxiliary engine which through a built-in UPS shuts the door.

OPERATION

GUIDE

LEAF

SHAFT

The leaf is made up of wooden slats soul bathed in fireproof resin thickness of 36 mm and a height of 72 mm, lined with a synthetic product of 0.8 mm with a unique manufacturing color gray RAL 7047, with perimeter boards expansion to make it completely waterproof..

Made of galvanized material 2 mm thick, U-shaped pipe welded to a reinforcement and its interior is built isolating joints to avoid chafing of the lamas and total measures 116 x 63 mm.

The tubular shaft is 3.6 to 7.1 mm in thickness and diameter varies in the same widths of 101.6 to 323.9 mm., Coupled with the extreme engine through solid shaft with keyway on bearings for lateral supports to slide over and get a proper curl..

05-5

FIRE RESISTENCE EI2 60 MINUTES

FLAME ROLL-UP DOORS

OPERATION

GUIDE

LEAF

The leaf is made of galvanized armored slats 130 mm in height and 0.8 / 0.9 mm thick united among themselves, with a drawing on the ends to prevent lateral movement. To give greater rigidity to the structure is placed a profile booster in the bottom of the door of 3 mm thick.

Made of galvanized material 2 mm thick, U-shaped pipe welded to a reinforcement and its interior is built insulation boards to avoid chafing of the lamas and total measures 80 x 63 mm.

FIRE RESISTENCE E / 120-240 MINUTES

SHAFT

The tubular shaft is 3.6 to 7.1 mm in thickness and diameter varies in the same widths of 101.6 to 323.9 mm., Coupled with the extreme engine through solid shaft with keyway, bearings, to slide on lateral supports and get a proper curl.

The flame roll-up doors are designed for the closure and segmentation of large voids, both in position always open, as in heavy use. Its operation is like any electric roller door, engineized vertical opening, Direct gear engine shaft 380 v. frontal displacement without compensation spring, operated by latchkey or button, in case of fire or alarm the control unit sends an electrical signal to the mail box and this means the engine shuts the door. Leaving the door fully closed and the action of fire intumescent expands board installed in the guides and the periphery of the door being fully sealed. In case of lack of electricity, the electric panel issues an order to a 24 VCC auxiliary engine which through a built-UPS * closes the door.

05-7

ROLL-UP DOOR EI 45 / 60

ROLL-UP DOOR MEC-IMPORT EI 60

ROLL-UP DOOR E 120/240

05-11

MECOSA

PRODUCTS

06 – CURTAINS

06-1

FIREBREAK CURTAINS

06-2

OPERATION

GUIDE

LEAF

Made with 1.2 mm galvanized material where the material slips with a guide for the proper collection of it.

The blade is made of high strength fabric that is wound in the top drawer leaf 1.2 mm thick and a lower counterweight to facilitate the fall, fabric finishes depend on the strength required and these can be as the related figures:

1.- E 60

2.- E 120

3.- E 240

4.- EI 120

The curtains to the sectorization of fire and smoke pipe, are fabrics made by high RESISTENCE to fire with special coating to withstand the high temperatures, are activated by engineing to 24 v. continuous or 230 v. Alternatively, allowing the closure and opening, controlled by an electrical panel, before the signal detection, alarm .

FIREBREAK CURTAINS

06-3

SHAFT Made with galvanized octagonal or cylindrical, where the fabric is wound with a guide for the proper collection of it.

06-5

CURTAIN E 120

CURTAIN E 240

CURTAIN EI 120

MECOSA

PRODUCTS

07 - SECTIONAL

07-1

SECTIONAL FIREBREAK DOORS

07-2

SECTIONAL FIREBREAK DOORS Model - MEC

The sectional firebreak doors are designed for the closure and segmentation of large voids, both in position always open, as in heavy use. Its operation is like any electric sectional door, engineized vertical opening, Direct gear engine shaft 380 v., with compensation of docks, operated by latchkey or button, in case of fire or alarm the control unit sends an electrical signal to the electronic box This means the engine shuts the door. Leaving the door fully closed and the action of fire intumescent expands board installed in the guides and the periphery of the door being fully sealed. In case of lack of electricity, the electric panel issues an order to a 24 VDC auxiliary engine which through a built-UPS * closes the door.

OPERATION

GUIDE

LEAF

FIRE RESISTENCE EI / 30 MINUTES

Made of galvanized material 2 mm thick, U-shaped pipe welded to a reinforced insulation joints to prevent rubbing of the leaf.

07-3

The blade is made from panels of 480/560 mm. tall with aluminum core and lined with fireproof timber of 10 mm thick, finished with fireproof white primer.

SHAFT

Compensation weight through torsion springs consisting of a diagonal axis lined with torsion springs, lateral cable drums, steel cables. The doors are equipped with a security system unbreakable spring.

SECTIONAL FIREBREAK DOORS Model MEC-IMPORT

The sectional firebreak doors are designed for the closure and segmentation of large voids, both in position always open, as in heavy use. Its operation is like any electric sectional door, enginerized vertical opening, Direct gear engine shaft 380 v. frontal displacement, with compensation of docks, operated by latchkey or button, in case of fire or alarm the control unit sends an electrical signal to the mail box and this means the engine shuts the door. Leaving the door fully closed and the action of fire intumescent expands board installed in the guides and the periphery of the door being fully sealed. In case of lack of electricity, the electric panel issues an order to a 24 VCC auxiliary engine which through a built-in UPS shuts the door.

OPERATION

GUIDE

LEAF

FIRE RESISTENCE EI / 60 MINUTES

The panel consists of wooden slats soul bathed in fireproof resin 40 mm thick, covered with synthetic product of 0.8 mm with a unique manufacturing color gray RAL 7047, with perimeter gaskets to make it completely waterproof expansion .

Made of galvanized material 2 mm thick, U-shaped pipe welded to a reinforcement and its interior is built isolating joints to prevent rubbing of the leaf.

07-6

SHAFT

Compensation weight through torsion springs consisting of a diagonal axis lined with torsion springs, lateral cable drums, steel cables. The doors are equipped with a security system unbreakable spring.

SECTIONAL DOOR

SECTIONAL DOOR (INSIDE)

SECTIONAL DOOR MEC- IMPORT

07-9

MECOSA

PRODUCTS

08 - SWING DOORS

- MODEL “FORTEX”

- MODEL “PAVERMEC”

- MODEL “BIG DIMENSIONS”

08-1

SWING FIREBREAK DOORS “MODELS” “FORTEX”

“PAVERMEC” “BIG DIMENSIONS”

08-2

1 / 2 LEAVES

SWING FIREBREAK DOORS MADE TO MEASURE MOD.: “FORTEX”

08-3

FIRE RESISTENCE EI2 C5 / 60 - 90 - 120 MINUTES

Most manufacturers of standard firebreak swing doors, reach peak production measures of height and width, when it is necessary a larger wing and strength, MECOSA can make it certifying his production.

The firebreak swing doors are designed for the closing and sectorizatión to hollows of special measures. In situation always closed, the automatic door-closing apparatus was acting when the door is opened, and in situation always opened when the sign of alarm issues an impulse to the electromagnet, this one is liberated staying the totally closed door and with the action of the fire the meeting expands intumescent installed in the whole perimeter of the door, remaining this sealed. Option can be automated and in case of lack of electrical fluid, the electrical picture closes the door. Always a sure network has to exist and in opposite case there is necessary a UPS that assures the necessary current to close the door.

OPERATION

FRAME

Frame made with sheet of steel outlined of 1,5 mm. Of thickness and hinges of great RESISTENCE.

Every this leaf constructed with two sheets of steel of 1,2 mm of thickness, (a thickness from 64 mm. Depending on the RESISTENCE to the fire wished) and joined by means of weld, landfill of rock wool of high density of 145 Kg./m3 and plate of fibersilicate to increase his RESISTENCE both to the fire and to the intense traffic thanks to his great hardiness. Manacles of black nylon and lock.

LEAF

REQUIRED DOOR-LOCK

And SELECTOR OF LEAVES

BY LAW

08-6

SWING FIREBREAK DOORS MADE TO MEASURE MOD.:“PAVERMEC”

FIRE RESISTENCE EI2 C5 / 60 - 90 - 120 MINUTES

FRAME

Frame made with sheet of steel outlined of 1,5 mm. Of thickness and hinges of great RESISTENCE.

Every this leaf constructed with two sheets of steel of 1,2 mm of thickness, (a thickness from 64 mm. Depending on the RESISTENCE to the fire wished) and joined by means of weld, landfill of rock wool of high density of 145 Kg./m3 and plate of fibersilicate to increase his RESISTENCE both to the fire and to the intense traffic thanks to his great hardiness. Manacles of black nylon and lock.

LEAF

Most manufacturers of standard firebreak swing doors, reach peak production measures of height and width, when it is necessary a larger wing and strength, MECOSA can make it certifying his production.

The firebreak swing doors are designed for the closing and sectorizatión to hollows of special measures. In situation always closed, the automatic door-closing apparatus was acting when the door is opened, and in situation always opened when the sign of alarm issues an impulse to the electromagnet, this one is liberated staying the totally closed door and with the action of the fire the meeting expands intumescent installed in the whole perimeter of the door, remaining this sealed. Option can be automated and in case of lack of electrical fluid, the electrical picture closes the door. Always a sure network has to exist and in opposite case there is necessary a UPS that assures the necessary current to close the door.

OPERATION

REQUIRED DOOR-LOCK

And SELECTOR OF LEAVES

BY LAW

BIG DIMENSIONS SWING FIREBREAK DOORS

08-9

The swing fire doors are designed for the closure and segmentation of large voids. In situation always closed, the door closer to act when the door opens, and open long position when the alarm emits a pulse to the electromagnet, this is released leaving the door fully closed and the action of fire intumescent expands board installed around the perimeter of the door being sealed. As an option can be automated and in case of lack of electricity, the electric locks the door. There must always be a secure, otherwise UPS is necessary to ensure the current required to close the door.

FIRE RESISTENCE EI2 / 60 - 120 MINUTES

Each leaf is built with two layers of pre-lacquered steel (0.6 / 0.8 mm thick) forming panels of 1150 mm wide tongue and groove, rock wool filling high density of 145 kg/m3. closed by their songs for a special U-profile 3 mm thick. Black nylon handles.

LEAF

OPERATION

FRAME

Frame made from high strength structural borders.

Most manufacturers of standard hinged doors, reach peak production measures of height and width, when it is necessary a larger wing and strength, MECOSA can manufacture certified doors with its elaboration same features as approved swing and sliding doors .

REQUIRED DOOR-LOCK

And SELECTOR OF LEAVES

BY LAW

SWING DOOR BIG DIMENSIONS SINGLE LEAF WITH INCORPORATED PEDESTRIAN DOOR

SWING DOOR BIG DIMENSIONS DOUBLE LEAVES

08-12

SWING DOOR MODEL FORTEX 1 & 2 LEAVES

SWING DOOR MODEL PAVER-MEC 1 & 2 LEAVES

MECOSA

PRODUCTS

09 – STANDARD SWING DOORS

09-1

STANDARD FIREBREAK SWING DOORS

DOUBLE LEAVES

SINGLE LEAF

09-2

DOOR DESCRIPTION EI2 60 SINGLE LEAF

FRAME

-CN6 frame three sides of high strength steel of 1.5 mm. with accommodation for cold smoke seal, and finished in RAL 7035 epoxy. - 6 feet of anchor with a size of 155 x 30 x 1.5 mm.

CN6

- Sheets of galvanized steel leaf Skinpassed type 54 mm thick in different finishes - Isolation ROCKWOOL stone wool 150 kg/m3 - DIN approved hinges, a spring actuated semi-automatic closing spring. - DIN lock and key cylinder patent - CRANK firewall anti-snag DIN polyamide with steel fireproof - An anti-levering point - Two strippers, in lock and bottom for installation - Identifying metal plate with approval EI2 60 - Instructions for assembly and maintenance - Weight of the blade 27 Kg./m2

LEAF

09-3

Lt=Exterme frame

Lp=Free access

Lfm=Hollow Works

Ht=

Ext

erm

e fra

me

Hp=

Free

acc

ess

Hfm

=Hol

low

wor

k H

+12

H=F

ram

e he

ight

REQUIRED DOOR-LOCK

And SELECTOR OF LEAVES

BY LAW

Sense of right opening (DX)

Sense of left opening (SX)

DOOR MEASURES EI2 60 1 LEAF FRAME CN6

09-4

LEGEND: L = width of leaf H = Height of leaf Lfm = hollow Width of work Hfm = Height hollow of work Lp = Broad free access Hp = Height free access Li = internal Width frame Hi = Height Inside frame Lt = Width outside frame Ht = Height outside frame

HOLLOW OF WORK FREE ACCESS INSIDE FRAME OUTSIDE FRAME

HOLLOW OF WORK FREE ACCESS INSIDE FRAME OUTSIDE FRAME

EQUIVALENCE TABLE

NOTICES: On order we can supply approved doors standard of height 2150 until 2400 from this measure can supply swing firebreak out of aproval, but with certification on the part of MECOSA of his construction with the same parameters that we make the sliding panels firebreak (EI)

DOOR DESCRIPTION EI2 60 2 LEAVES

- CN6 three-sided frame in high strength steel of 1.5 mm. with accommodation for cold smoke seal, and finished in RAL 7035 epoxy. - Board intumescent in frame, DIN 2.5 x 20 mm. - 9 anchor legs to a maximum size of 2000 mm hollow force. Above the framework of this measure comes with 11 anchor legs. The dimensions of the anchor legs 186 x 25 x 1.5 mm.

FRAMES

CN6

- Leaf of galvanized steel leaf Skinpassed type 54 mm thick in different finishes - rockwool insulation ROCKWOOL 150 kg/m3 - DIN approved hinges, a spring actuated semi-automatic closing spring. - DIN lock and key cylinder patent - Sheet of 2 fitted secondary latches Camor either lock. - CRANK firewall anti-snag DIN polyamide with steel fireproof. - Two anti-levering points - Four spacers between leaves and 2 greater between sash and frame. - Closing Selector - Instructions for assembly and maintenance - Weight of the blade 27 Kg./m2

LEAF

09-5

Lt=Exterme frame

Lp=Free access

Lfm=Hollow Works

Ht=

Ext

erm

e fra

me

Hp=

Free

acc

ess

Hfm

=Hol

low

wor

k H

+10

H=F

ram

e he

ight

Lpa=Free access primary leaf = L1-92

REQUIRED DOOR-LOCK

And SELECTOR OF LEAVES

BY LAW Sense of right opening (DX)

Sense of left opening (SX)

09-6

DOOR DESCRIPTION EI2 60 2 LEAVES LEGEND: L = width of leaf H = Height of leaf Lfm = Hollow Width of work Hfm = Height hollow of work Lp = Broad free access Hp = Height free access Li = Internal Width frame Hi = Height Inside frame Lt = Width outside frame Ht = Height outside frame

HOLLOW OF WORK FREE ACCESS INSIDE FRAME OUTSIDE FRAME

WORK HOLLOW Lfm x Hfm

FREE ACCESS Lp x Hp

INSIDE FRAME Li x Hi

OUTSIDE FRAME Lt x Ht

EQUIVALENCE TABLE

NOTICES: On order we can supply approved doors standard of height 2150 until 2400 from this measure can supply swing firebreak out of aproval, but with certification on the part of MECOSA of his construction with the same parameters that we make the sliding panels firebreak (EI)

09-7

DOOR DESCRIPTION EI2 120 SINGLE LEAF

FRAME

-CN6 three-sided frame high strength steel of 1.5 mm. with accommodation for cold smoke seal, and finished in RAL 7035 epoxy. - 8 feet of anchor with a size of 155 x 30 x 1.5 mm.

CN6

- Leaves of galvanized steel leaf of 64 mm type Skinpassed thickness in different finishes - Isolation ROCKWOOL stone wool 180 kg/m3 - 2 DIN approved hinges, a spring actuated semi-automatic closing spring and the other with ball fields and height adjustment. - Two anti-levering points. - DIN lock and key cylinder patent - CRANK firewall anti-snag DIN polyamide with steel fireproof. - Two strippers, in lock and bottom for installation - Identifying metal plate with approval EI2 120 - Instructions for assembly and maintenance - Weight of the blade 37.7 Kg./m2

LEAF

Lt=Exterme frame

Lp=Free access

Lfm=Hollow Works

Ht=

Ext

erm

e fra

me

Hp=

Free

acc

ess

Hfm

=Hol

low

wor

k H

+12

H=F

ram

e he

ight

REQUIRED DOOR-LOCK

And SELECTOR OF LEAVES

BY LAW

Sense of right opening (DX)

Sense of left opening (SX)

09-8

LEGEND: L = width of leaf H = Height of leaf Lfm = Hollow Width of work Hfm = Height hollow of work Lp = Broad free access Hp = Height free access Li = Internal Width frame Hi = Height Inside frame Lt = Width outside frame Ht = Height outside frame

HOLLOW OF WORK FREE ACCESS INSIDE FRAME OUTSIDE FRAME

HOLLOW OF WORK FREE ACCESS INSIDE FRAME OUTSIDE FRAME

EQUIVALENCE TABLE

NOTICES: On order we can supply approved doors standard of height 2150 until 2400 from this measure can supply swing firebreak out of aproval, but with certification on the part of MECOSA of his construction with the same parameters that we make the sliding panels firebreak (EI)

DOOR DESCRIPTION EI2 120 SINGLE LEAF

09-9

DOOR DESCRIPTION EI2 120 2 LEAVES

-CN6 three-sided frame high strength steel of 1.5 mm. with accommodation for cold smoke seal, and finished in RAL 7035 epoxy. - Board intumescent in frame, DIN 3 x 30 mm. - 9 feet of anchor work of 155 x 30 x 1.5 mm.

FRAMES

CN6

- Leaf of galvanized steel leaf of 64 mm type Skinpassed thickness in different finishes - Rock wool insulation ISOVER ROCKWOOL-180 kg/m3 - 4 DIN approved hinges, a spring actuated semi-automatic closing spring, the other with ball fields and height adjustment - DIN lock and key cylinder patent - Sheet of 2 fitted secondary latches Camor either counterlock. - CRANK firewall anti-snag DIN polyamide with steel fireproof. - Flash bolt manual. Rod sup / inf automatically operated. - Four point anti-levering - Four spacers between leaves and 2 greater between sash and frame. - Closing Selector - Instructions for assembly and maintenance - Weight of the blade 37.7 Kg./m2

LEAF

Lt=Exterme frame

Lp=Free access

Lfm=Hollow Works

Ht=

Ext

erm

e fra

me

Hp=

Free

acc

ess

Hfm

=Hol

low

wor

k H

+10

H=F

ram

e he

ight

Lpa=Free access primary leaf = L1-92

REQUIRED DOOR-LOCK

And SELECTOR OF LEAVES

BY LAW Sense of right opening (DX)

Sense of left opening (SX)

09-10

LEGEND: L = width of leaf H = Height of leaf Lfm = Hollow Width of work Hfm = Height hollow of work Lp = Broad free access Hp = Height free access Li = Internal Width frame Hi = Height Inside frame Lt = Width outside frame Ht = Height outside frame

EQUIVALENCE TABLE

NOTICES: On order we can supply approved doors standard of height 2150 until 2400 from this measure can supply swing firebreak out of aproval, but with certification on the part of MECOSA of his construction with the same parameters that we make the sliding panels firebreak (EI)

LEAF DEVELOPEMENT (L1+L2) x H

OUTSIDE FRAME Lt x Ht

INSIDE FRAME Li x Hi

FREE ACCESS Lp x Hp

WORK HOLLOW Lfm x Hfm

DOOR DESCRIPTION EI2 120 2 LEAVES

LEAF DEVELOPEMENT OUTSIDE FRAME Lt x Ht

INSIDE FRAME Li x Hi

FREE ACCESS Lp x Hp

WORK HOLLOW Lfm x Hfm

FRAME DETAIL CN6 AND METAL PRE-FRAME FOR EI2 60

09-11

MINIMUM 27

09-12

FRAME DETAIL CN6 AND METAL PRE-FRAME FOR EI2 120

MINIMUM 27

FRAME PLACEMENT

09-13

The embrace-walls MC6 of 1.5mm. For frame MC3, mounted by means of weld or screwed. Embraces-walls to screw they are supplied free for his installation by the client.

a

Claw Screw b c d

EI 60 20 30 33 65 Since thickness wall

EI120 30 43 75 Since thickness wall

With Claw

With Screw

With Claw

With Screw

TECHNICAL DESCRIPTION OF COATINGS

09-14

STANDARD DESCRIPTION: TECHNICAL CHARACTERISTICS Plate type: Steel DX-51 low in Carbon, galvanized in I continue Aspect: Painting greyish color on galvanized sheet skispass. For dip in warm for conformation in cold, according to norm Test of saline fog:> 240 hours. EN-10142. Chamber of Dampness:> 500 hours. Covering: Galvanized Z-100. Finished exterior: Painting polyester RAL 7035 with thickness from 12 to 15 microns and protection film of 50 microns.

PAINT METODOLOGY Steps to apply the paint: - To prepare the painting in conformity with the specifications of the manufacturer. - To withdraw the protection filter of the leaf. - To clean the whole surface softly with solvent, to eliminate the particles of dirt, specially in the corners and folded. Conditions of application: Temperature: ºC 10-45 Relative dampness % 0-85 Times of dried: Temperature Tact (hrs) Total (hrs) Interval Repainted (hrs) Min. Max. 10ºC 2-3 14 24 72 20ºC 1-2 8 18 48 30ºC _-11/2 6 12 36 Equipments of application: Conventional pistol: Orifice mouthpiece: inch. 0.055 - 0.070 Pressure angers: Kg/cm2 3.1 - 4.2 Pressure painting: Kg/cm2 0.7 - 1.4 Dilution: % 0 - 101/2 Pistol Airless: Orifice mouthpiece: inch. 0.015 - 0.019 Relation compression: - 30:1 Pressure I work: Kg/cm2 150 - 170 Dilution: % 0 – 5 Adapted for: Rural, marine and industrial very aggressive environment, dip in water. Not adapted for: Dip continues in chemical products. Caps of bottom: Cromoglas Fixative AH, Epocrom Primer, Epocrom Primer FA, Epocrom Primer Rich Zinc 90, Epomastic Fondo, Epomastic, Epocrom, Epocrom HB Holding company, Cromoglas Satinated. Security: Product flammable. Toxin for inhalation and ingestion. To avoid the contact with the skin and eyes. If it is applied to pistol to have suitable ventilation and under respiratory protection. Notices: There is very important the cleanliness of the sheet of any substance (prowder, oil, fat …) to avoid any problem of later adherence of the painting.

COLOR COATINGS

STAINLESS COATING

09-15

COLOR TABLE RAL/DECO

RAL 3000 EMBOSSING

RAL 1013 SMOOTH/EMBOSSING

RAL 3003 EMBOSSING

RAL 5007 EMBOSSING

RAL 5010 EMBOSSING

RAL 6005 EMBOSSING

RAL 6033 EMBOSSING

RAL 7010 EMBOSSING

RAL 7035 SMOOTH

RAL 9001 EMBOSSING RAL 9010

EMBOSSING RAL 9011

EMBOSSING

COLOR TABLE DECO SPECIAL

YELLOW CREAM ALUMINIUM GRAY ALUMINIUM INOX OAK OLD OAK SAPELLY NEW PINE

WALNUT TANGERINE BEECH CHERRY-TREE

FIREBREAK ACUSTIC DOOR SINGLE LEAF

09-16

DESCRIPTION: The AS Acoustic it has the possibility of there being installed in its entirety or only those components that are considered oportune to obtain the acoustic level to wished isolation, since it is possible to observe into the next combination table.

DOORS A LEAF The acoustic door a leaf has the following characteristics: Acoustic KA 5 kit. - 3 faces in the frame CN6 steel of high RESISTENCE 1,5mm. Gray RAL 7035, with housing for meeting of cold smokes. Ended in epoxi polymerized to the oven. - Sheet of galvanized steel type skinpass. Pre-painted in Grey RAL 7035 of 64mm of thickness for EI2 120. - Hinges approved by the CE.

- Spyhole firewall anti-lock Norm DIN, In polyamide fireproof with core of steel. - Points anti-lever: El2 120, 2 points. - Claw of anchorage on the frame: EI2 120 (8 Claws) - Dividers for his installation. - Identification with homologation EI2. - Assembly and maintenance manual. - Lock CE approved and cylinder “patent key”.

- Isolation of rock wool El2 120 :180 kg/m3, Thickness. 30 + 30. - Weight of the leaf. El2 120 : 37,5 kg/m2. - Lock CE approved and cylinder “patent key”.

43 dB Leaf EI2 120

W I T H O U T A C U S T I C K I T

VERTICAL SECTION AND DETAILS OF THE DOOR WITH ACOUSTIC KIT

09-17

FIREBREAK ACUSTIC DOOR DOUBLE LEAVES

DESCRIPTION: The AS Acoustic it has the possibility of there being installed in its entirety or only those components that are considered oportune to obtain the acoustic level to wished isolation, since it is possible to observe into the next combination table.

DOORS A LEAF The double leaves acoustic door has the following characteristics: Acoustic KA 5 kit. - 3 faces in the frame MC3 steel of high RESISTENCE 1,5mm. Gray RAL 7035, with housing for meeting of cold smokes. Ended in epoxi polymerized to the oven. - Sheet of galvanized steel type skinpass. Pre-painted in Grey RAL 7035 of 64mm of thickness for EI2 120. - Hinges approved by the CE.

- Spyhole firewall anti-lock Norm DIN, In polyamide fireproof with core of steel. - Points anti-lever: El2 120, 4 points. - Claws of anchorage in the frame: Up to a maximum to 2000mm 9 claws, up of 2000mm 11 claws. - Dividers for his installation. - Identification with homologation EI2. - Assembly and maintenance manual.

- Isolation of rock wool El2 120 :180 kg/m3, Thickness. 30 + 30. - Weight of the leaf. El2 120 : 37,5 kg/m2. - Lock CE approved and cylinder “patent key”.

35 dB Leaf EI2 120

Acoustic Kit: Set of meetings that grant the door acoustic isolation.

ACOUSTIC ISOLATION IN DECIBELS

WITHOUT KIT

Frame: 4 sided steel of 1.5 mm. Galvanized steel leaf of 54 mm. thick Rock wool insulation of 150 / 180 kg/m3, 50 mm thick. Hinge CE approved. Triangle with standard lock spindle option. Leaf Weight 27 kg / m2

REGISTRES EI2 60/120

09-18

REGISTER DIMENSIONS TO SINGLE LEAF EI2 From 300mm to hight x 400mm to width. Since 1000mm to hight x 2150mm to width. REGISTER DIMENSIONS TO DOUBLE LEAVES EI2 The secondary leaf always is to be more high that broad. From 600mm to hight x 400mm to width. Since 2000mm to hight x 2150mm to width.

DOUBLE LEAVES

SINGLE LEAF

09-19

09-20

WOODEN DOOR DESCRIPTION EI2

FRAMES High density wooden frame Fireproof interior board Finished in raw MDF or wood board to choose Red Intumescent joint (other colors upon request)

LEAF Raw MDF or wood capping to choose Rubber weatherstripping brown or black (other colors upon request) Note: For acoustic EI 60 to 62 mm, EI90 and E120 single black weatherstripping Raw MDF or wood capping to choose Hinges IGLE, minimum 4 units Concealed hinges (optional on the hinges)

REQUIRED DOOR-LOCK

And SELECTOR OF LEAVES

BY LAW Sense of right opening (DX)

Sense of left opening (SX)

FIBERS BUDINGA CEDAR CHERY-TREE MUKALY BEECH

SAPELY OAK IROKO EMBER WALNUT PINE

SAPELY BRANCHED ESTRATIFICATED ESTRATIF. ESPEC.

09-21

RESISTENCE Door Kind Measures

Leaf height Leaf width Leaf Thickness Glass

EI30

1 LEAF 2200 1025 40

1 LEAF + GLASS 2030 825 40 Ø48

1 LEAF + TOP TALLY 2200 + 630 925 40

1 LEAF METAL FRAME 2110 925 40

EI30 35 dB 1 LEAF 2110 925 55

EI30 40 dB 1 LEAF 2110 925 55

RESISTENCE & MEASURES TABLE

WOODEN DOOR COATINGS EI2

RESISTENCE Door Kind Measures

Leaf height Leaf width Leaf thickness Glass

EI60

1 LEAF 2200 1025 50

1 CURVED LEAF 2400 1025 62

2 LEAVES 2200 925 + 925 50

2 LEAVES + TOP TALLY 2030 + 470 825 + 825 50

1 SPECIAL LEAF 3000 925 62

2 SPECIAL LEAVES 3000 925 + 925 62

1 LEAF + GLASS 2100 925 62 400 x 400

2 LEAVES + GLASS 2100 925 + 925 62 400 x 400

EI90

1 LEAF 2400 1025 56

2 LEAVES 2800 1600 + 1600 56

1 LEAF + GLASS 2250 825 60 355 x 355

2 LEAVES + GLASS 2500 825 + 825 60 550 x 550

E120 2 LEAVES 2500 1500 + 1500 56

09-22

WOODEN DOOR COATINGS EI2

1 LEAF

1 LEAF WITH SPYHOLE

2 LEAVES WITH ANTI-PANIC

09-23

MECOSA

PRODUCTS

10 - ENGINES

10-1

ENGINES FOR SLIDING DOORS WITH COUNTERWEIGHT

1 .- OBSTACLE DETECTION MODEL OPERATION This system MEC Model 570 (S / D) consists of a speed regulator and an electromagnet to the alarm or fire, short of turning off the electric fluid retention and ensuring the door by the counterbalance its closure, with a controlled speed . With the photocell can manage the security of the obstacle detection, since the cut line of action of the photocell stops the travel of the door and continued until his release is not closure. The difference between the model MEC MEC 570 S and 570 D includes the MEC 570D supports more weight and yards of travel of the door. DC-220 V. phase and 24 V. dc voltage.

570 S 24 VCC COUNTERWEIGHT 6 m 1400 Kg. Regulator + solenoid + OPC photocell 570 D 24 VCC COUNTERWEIGHT 12 m 2000 Kg Regulator + solenoid + OPC photocell

MOD VOLTAGE CLOSED BY WIDTH / WEIGHT SISTEM

24 VCC RETURN POLLEY 6 m 1400 Kg. Regulator + solenoid + OPC photocell

MEC Model 650 has the same characteristics as the MEC 570 S except that it has no counterweight but wire –stretcher to ensure the closure of the door MEC Model 850 has the same characteristics as the MEC 570 D with the difference that has no counterweight but wire-stretcher to ensure the closure of the door and less travel from the door.

MEC 650 MEC 570 S/D y MEC 850

For the operation of the engines must have maneuver box MEC G

Within the range of drives for fire doors, we can classify them into three families: 1 .- OBSTACLE DETECTION MODEL 2 .- SEMI-AUTOMATIC MODEL 3 .- AUTOMATIC MODEL

10-2

650

24 VCC RETURN POLLEY 8,5 m 2000 Kg. Regulator + solenoid + OPC photocell 850 WIRE-STRETCHER

WIRE-STRETCHER

The maneuver box MEC Model G, consists of a circuit function, a power supply of 230 VAC / 24 VDC and accumulators autoloading. In the event of network failure accumulators maintain output of 24 VAC / 400 mA for 2 hours. Faced with a fire alarm or power failure, power output is as follows: 1 .- From the main network 230 VAC (single) through the rectifier 24 VDC. 2 .- Without mains from the emergency battery 12 V / 1,5 Ah. 3 .- For failure of the emergency battery, extra battery from 9.6 V / 1.2 Ah. MEC Table G, is valid for engines MEC 570 and MEC 650

OPERTAION

MANEUVER BOX MEC G

MEC G 230AC/50Hz 24 VCC 300 X 220 X 120 SI max. Autonomy 2 h.

MOD CONNETION TRANSFORMATION MEASURES EMERGENCY ACCUMULATORS

MANEUVER BOX FOR SLIDING DOORS WITH COUNTERWEIGHT

10-3

ENGINES FOR SLIDING DOORS WITH COUNTERWEIGHT

2.- SEMIAUTOMATIC MODEL

OPERATION

These model systems MEC 3700, MEC 7000 , MEC 700 and MEC 8000 and electrical fittings that open the door, kept open in any position by an electromagnet and integrated controls closing speed by a speed regulator. The electromagnet before the alarm, fire or failure of electricity (acting maneuvers box) cuts the electric fluid retention clearing and securing the door by the counterbalance its closure. With the photocell can manage the security of the obstacle detection, since the cut line of action of the photocell stops the travel of the door and continued until his release is not closure. In both systems MEC 3700, MEC 7000, there are two closing performances, one for position control integrated with end SE and other career ZL MEC 700. In 8000 ECM only. DC-220 V. phase and 24/48 V. current.

3700 ZL/SE 24 VDC COUNTERWEIGHT 7m -12 m /700 Kg . Engine + timing belt + box + final/c – control/position

MOD VOLTAGE CLOSED BY WIDTH / WEIGHT SISTEM

3700 ZL/SE 40 W - 300 N 10 N 10 Kg. Adjustable 0,10-0,25 m/s Adjustable 0,08-0,2 m/s MOD POWER/ENGINE TORQUE WEIGHT/ENGINE SPEED/APPERTURE SPEED/CLOSE

7000 ZL/SE 48 VDC COUNTERWEIGHT 7m -12 m / 1300 Kg. Engine + timing belt + box + final/c – control/position

8000 SE 48 VDC WIRE-STRETCHER 7m / 1000 Kg. Engine + timing belt + box + control/position

7000 ZL/SE 157 W - 600 N 20 N 10 Kg. Adjustable 0,10-0,18 m/s Adjustable 0,08-0,2 m/s

8000 SE 157 W - 600 N 20 N 19 Kg. Adjustable 0,10-0,18 m/s Adjustable 0,08-0,2 m/s

MEC 3700 MEC 7000 MEC 8000

To operate these engines most use maneuver box MEC E8

10-4

700 ZL 230/4008 V WIRE-STRETCHER 20m / 3000 Kg. Engine + timing belt + box + control/position

700 ZL 0,18 KW - 800 N 70 N 23 Kg. Adjustable 0,10-0,18 m/s Adjustable 0,08-0,2 m/s

MEC 700

ENGINES FOR SLIDING DOORS WITH COUNTERWEIGHT

3.- AUTOMATIC MODEL

OPERATION

MEC Model 900 system electrical fittings that open and close the door also remains open in any position by an electromagnet and integrated controls closing speed by a speed regulator. The electromagnet before the alarm, fire or failure of electricity (acting maneuvers box) cuts the electric fluid retention clearing and securing the door by the counterbalance its closure. With the photocell can manage the security of the obstacle detection, since the cut line of action of the photocell stops the travel of the door and continued until his release is not closure. Execution is by closing switches. Can also be supplied with explosion protection - proof. DC-220 V. single phase and 380V. AC. Always connected to the electrical box.

MOD VOLTAGE CLOSE BY WIDTH/WEIGHT SISTEM

MOD POWER/ENGINE TORQUE WEIGHT/ENGINE SPEED/APPERTURE SPEED/CLOSE

900 230/400 V COUNTERWEIGTH 100m / 15000 Kg. Engine + timing belt + box + final position.

900 0,55 kW a 2200 N 150 N 40 Kg. Adjustable 0,10-0,18 m/s Adjustable 0,08-0,2 m/s

To operate these engine must use maneuver box MEC E8

MEC 900

10-5

ENGINES FOR SLIDING DOORS WITH COUNTERWEIGHT

The maneuver box MEC Model E8, is developed for motors and alternating current, delivered at two possibilities in ABS box or metal enclosure with integrated UPS (UPS keeps the door open (coil) when there is a network failure and powered smoke detectors and security features. All settings of the properties of the motor are made with the camera move over the keyboard with integrated display on the lid of the box, except the configuration of the internal switches for the operation of man This, momentum and potential free contact.

OPERATION

MANEUVER BOX MEC E8

MEC E8 230AC/50Hz 24 – 48 VDC Máx. 120W 310 x 230 x 130 355 x 355 x 120

MOD CONNECTION TRANSFORMATION OUTPUT POWER MEASURES E8 / E8 UPS

10-6

ENGINES FOR SLIDING DOORS WITHOUT COUNTERWEIGHT

OPERATION

The system model MEC GL, MEC GS electrical fittings that open and close the door. The MEC GL is indicated and telescopic doors designed to move multiple sheets (large size), MEC GS is suitable for sliding doors 1 or 2 leaves. The engines always operate without a counterweight.

* A safe power line or the placement of a UPS is always needed.

10-7

MOD.-GL/GS VOLTAGE CLOSE BY POWER SISTEM

Three phase 1 380 V Race Ended 0,33 Hp (0,25 Kw.) Asynchronous

Three phase 2 380 V Race Ended 0,50 Hp (0,37 Kw.) Asynchronous

Simple phase 240 V Race Ended 0,33 Hp (0,25 Kw.) Asynchronous

ENGINES FOR GUILLOTINES AND OVERHEAD DOORS

OPERATION

MOD TORQUE FREQUENCY CONSUMPTION SPEED SPEED/REDUCTION

Simple phase 23 Nm 50 Hz. 1,8 A (220 V) 5,5 m/min. 35 r.p.m.

Three phase 23 Nm 50 Hz. 1,2 A (220 V) - 0,9 A (380 V) 5,5 m/min. 35 r.p.m.

Three phase 34,5 Nm 50 Hz. 2 A (220 V) - 1,15 A (380 V) 5,5 m/min. 35 r.p.m.

To operate these engine must use maneuver box MEC MTG

The system MEC G has electrical fittings that open and close the door. The MEC GL is indicated and designed to move guillotine and overhead doors.

10-8

MOD.-GL/GS VOLTAGE CLOSE BY POWER SISTEM

Three phase 1 380 V Race Ended 0,33 Hp (0,25 Kw.) Asynchronous

Three phase 2 380 V Race Ended 0,50 Hp (0,37 Kw.) Asynchronous

Simple phase 240 V Race Ended 0,33 Hp (0,25 Kw.) Asynchronous

MANEUVER BOX FOR SLIDING DOORS WITHOUT COUNTERWEIGHT GUILLOTINES AND OVERHEAD WITH COUNTERWEIGHT

The maneuver box Model MEC MTG, is developed for single phase or three phase motors are delivered boxed ABS. and on / off switch on the outside, opening and closing by “present man". All adjustments to the properties of the motor are made to the table without power supply.

OPERATION

MANEUVER BOX MEC MTG

MOD CONNETION TORQUE OUTPUT POWER DIMENSIONS

MTG 400 V Trif / 230 V Mono 3 CV Trif / 1,5 CV Mono 0,5 A 225 x 195 x 85 mm.

10-9

EMERGENCY POWER SUPPLY FOR ENGINES (UPS)

OPERATION

UPS System Model 600 - 1000 - 3000 emergency feeding is suitable for any use. The outputs available are: SA always fed and emergency only. They can be used together or independently, but respecting the power rating of the system. The possibility exists SCHUKO connector on the bottom, as output SA (always powered) in 1000 and 3000 models. The Model 600 carries two batteries of 7.2 Ah outside with a range of 11 minutes.

UPS 600 w + 2 batteries 7,2 AH UPS 1000 w UPS 3000 w

The system includes a voltage stabilizer, operational at all times, with or without mains. The electromagnetic capability respects the standard EN 50091-2, 89/336/EEC and 93/68/EEC.

10-10

ENGINES FOR GLASS SLIDING DOORS EI2

OPERATION

The model MEC 09 system, is an electric motor that opens and closes the door also remains open to monitor the security by detecting obstacles in any position by a photocell controls the closing speed to obstacle detection. Before the alarm, fire or failure of electricity (works the control panel) ensuring the closure of the door. The system consists of an engine-gearbox, power supply, microprocessor box, emergency battery unit, cars and sliding guide.

MEC 09 240 VAC / 50 Hz 250 W 2000mm/2400mm Adjustable 15 / 55 cm/s MOD VOLTAGE CONSUMPTION Máx WIDTH/HEIGHT SPEED/APPERTURE-CLOSE

MOD STREIGHT/ENGINE OUTPUT Máx WEIGHT APERTURE-CLOSE STOP

MEC 09 100 / 150 N 24 VDC 140 Kg./Hoja Adjustable 1 / 50 cm.

10-11

ENGINES FOR SWING DOORS EI2

OPERATION

Model MEC BAT system is an electro-hydraulic motor that opens and closes the door also remains open to monitor the security by detecting obstacles in any position by a security sensor or the program selector. Before the alarm, fire or failure of electricity automatically closes the door spring, controlling the closing speed independently.

LEAF

Model MEC BAT system can be installed on swing gates of one or two leaves, and in turn with metal borders, glass and opaque. Their action can be thrust or traction.

MODEL VOLTAGE-AUX.VOLTAGE CONSUMPTION TEMP. Max WEIGTH Max WIDTH

MEC-BAT 230 VAC/12-20-24 VDC 230 W -15º a + 50º 250 Kg. 1600 mm.

10-12

ENGINES FOR ROLL-UP AND SECTIONAL FIREBREAK DOORS

OPERATION

Model MEC RS system is an electro motor with helical wheel high quality brass switches and switch and security. In case of fire alarm the door closes automatically in case of lack of electricity, the engine has another built-phase auxiliary motor through the information that reaches the maneuver box, connects to a battery operated emergency closing the shutter, makes a single move of closing.

DATA UNITS RDFN 4-12 RDFN 7-12 RDFN 8-10 RDFN 9-10 RDNF 10-7

Diámer axis mm. 30 40 55 55 55

For the operation of these engine must use maneuver box MEC 10

Torque Nm 290 550 750 1000 1400

Output min.-1 12 12 10 10 7

Power engine Kw. 1,1 1,5 2,0 2,2 2,2

Input Voltage V 3~230/400V 3~230/400V 3~230/400V 3~230/400V 3~230/400V

Frequency Hz 50 50 50 50 50

Control Voltage V 24 24 24 24 24

Match Factor ED S3-60% S3-80% S3-60% S3-60% S3-60%

Cable mm2 5 x 1,5 5 x 1,5 5 x 1,5 5 x 1,5 5 x 1,5

Interval opera. 10 10 10 10 10

Temperature ºC -5 a +40 -5 a +40 -5 a +40 5 a +40 -5 a +40

Acústic dB (A) < 70 < 70 < 70 < 70 < 70

Protecc. Índex IP 54 54 54 54 54

10-13

ENGINE FOR ROLL-UP AND SECTIONAL DOORS

OPERATION

MANEUVER BOX MEC 10

The maneuver box Model MEC 10, is developed for three-phase motors are manufactured in steel, all settings of the properties of the motor are made from the open control panel.

INPUT …………………………………………… 3 x 400 VDC 50 Hz. BORNE CONECTION …………………………………… 1,5 mm2 aprox. MANEUVER VOLTAGE ………………………. 24 VDC SECONDARY FUSE ………………………….. 0,8 A inerte. PROTECTION DEGREE ……………………… IP 54 (IP 65) REMOTE CONTROL …………………………. Yes (via radio.) EMERGENCY BATTERY …………………….. 2 X 24 V OPTION. DIMENSIONS ………………………………….. 250 wide x 120 high x 180 deep.

10-14

MECOSA

PRODUCTS

011 – FIREBREAK PANEL

11-1

FIREBREAK PANEL

11-2

FIREBREAK PANEL

The panels are designed for the segmentation of large holes, lined walls or in any location where you would seal a place for mandatory sectorize

The panel is constructed with two sheets of galvanized steel or pre-lacquered (0.6 / 0.8 mm thick) forming tongued and grooved panels of 1150 mm wide, rock wool filling high density of 145 kg/m3.

PANEL

11-3

FIRE RESISTENCE EI2 / 60-90-120-180-240 MINUTES

Panel EI 60 60 mm 17 Kg. /m2

Panel EI 90 60 mm 17 Kg. /m2

Panel EI 120 80 mm 23 Kg. /m2

Panel EI 180 100 mm 29 Kg. /m2

Panel EI 240 117 mm 34 Kg. /m2

MODEL THICKNESS WEIGHT

TONGED AND GROOVED PANEL

VERTICAL PANEL

CEILING PANEL

11-4

MECOSA

PRODUCTS

012 - ACCESORIES

12-1

SHOCK ABSORBER

The MEC shock absorber without recoil spring magnet, dampens the closures of fire doors with no impediment. When you open the door the magnet located in the head shock returns the stem to the outside

OPERATION

BOX

The MEC shock absorber is made of a steel cylinder, two nuts for fixing The anchor brackets are also made of steel. The regulation of the impact force is done by turning the stem completely removed

TOUR Máx.. LOAD RECOIL FPRCE LENGTH MAGNET

50 mm. 5200 N. 0 +/- 130 32 diam.

12-2

SPEED REGULATOR

MEC speed regulator controls the speed of movement in a limited run in fire doors. Damping rate occurs with the help of a steel cable stretched between three driven pulleys.

OPERATION

BOX

MEC speed regulator is made of steel, with two of the pulleys at the ends of synthetic material and an aluminum core, for speed control without staging is done via an adjustment screw. And a thermostatic valve automatically balances the influences of temperature between -15

and + 70 º C.

12-3

RETURN POLLEY (CABLE-STRETCHER)

The MEC end pulleys are used in fire doors closing as regulatory system

Don’t need a special assembly, through the self-tensioning and the sprocket clutches may vary once the tension mounted. MEC return pulleys 120 N or 320 N. are officially verified closure system gates firewall, under standard MPA-NRW C. Do No 15.4

OPERATION

Material ………………….. Steel Coating …………………. Type 160N pulverized covering RAL 7036 Type 320 N galvanized. Working race …..……… 6,5 m. Steel cable …..………… 10 m. Diameter 3 mm.

12-4

ELECTROMAGNETS

The electromagnet with release button is built by a black enameled steel body and plated coil block. Complies with CE UNE 1155.

The counterplate consists of a round steel body with an anchor round rubber articulated joint for the galvanized metal base with a diameter of 55 mm counterplate.

The electromagnet with release button has the characteristics of pavement identical to the earlier techniques but the placing on the pavement.

ELECTROMANET RET 55 Kg.

ELECTROMANET RET 140 Kg.

Input Electrical Absortion

24 VCC

24 VCC

70 mA

70 mA

Posible 12 v

YES

YES

Conector varistor antiparasitic

YES

YES

Countermagnetism magnet body

YES

YES

11-5

SUCTION ELECTROMAGNETS

SECURITY

They are installed on the inside of the door, the different methods used to vandalize and open locks do not affect Electromagnetic Suction. The Suction Electromagnetic have no moving mechanical parts, therefore can never be locked doors. Suitable for emergency exits, and in case of fire escape door fast. They do not suffer mechanical wear, perfectly resist a high level of maneuvers and require no maintenance. Different credit checks carried out when your power goes out opening occurs instantly, and do not see any residual magnetism. Corrosion RESISTENCE Standard UNI ISO 9227, legislation 89/336/EEC (EN 55014) of the electromagnetic compatibility.

12-6

POWER MAGNE. CLOSING 1800 Nw 3000 Nw 6000 Nw

VOLTAGE 12 V DC 12 V / 24 V DC 12 V / 24 V DC CONSUMPTION 250 mA 270 / 180 mA 270 / 180 mA

POWER 3 W 3 , 3 W 3 , 3 W

FIRE PROOF ELECTROMAGNETS

These electromagnets are proof of the implementation of the Group II for hazardous compounds are made from a capped airtight and are supplied with a spark arrester protection diode, which conforms to the requirements PTB ATEX 03 and ATEX N060.

12-7

Electric connection 24 VDC Consumption 67 mA (1,6 W) / 70 mA (1,7 W) Strength 550 N / 1450 N Protection IP 66 Working temperature - 20 to + 40ºC Coating Magnet galvanized, painted gray box connections

THERMAL FUSE

The thermal fuse retainer performs the function of the fire doors when no one can put the electromagnet, this is melted from 68 - 70 º C to release the door and closing.

OPERATION

The thermal fuse has two options, a metal alloy that is standard equipment, and other chemical capsule option.

BODY

STANDAR D

OPTION

12-8

LOCKS

FOR 1 LEAF DOORS OR OTHER PRIMARIES SECONDARY LEAF LOCK

12-9

STANDARD LOCK

-DIN

- Reversible

SPECIAL PANIC LOCK

-DIN anti-panic

-Reversible

- Adjustment of the length of the bolt

COUNTER-LOCK

(Anti-panic)

LOCKS CILINDRERS

Standard cylinder model patent

For doors EI2 60 of 74 mm. For doors EI2 120 of 84 mm. Metal knob and cylinder

For doors EI2 60 of 74 mm. For doors EI2 120 of 84 mm. Metal cylinder

12-10

On request we supply cylinder of water companies, electricity and gas.

MEC cylinders can be supplied as individual locking cylinders, or trained in closure ranked at will. The system has the related certificates pursuant to 1303 UNE security cylinders.

TRAININGS

12-11

LOCKS TO HOTELS

HOTEL MEC 760 locks are designed to ensure seamless integration into any environment, allowing you to control access to different rooms. The magnetic stripe system cheaper and easier to install, suitable even for outdoors.

OPERATION

MODEL DENTIFICATION TECHNOLOGY READER RECEPTION CONSOLE SOFTWARE

MEC H760 Magnétic Band Reader Clásic Atlas

12-12

ACCES CONTROL KEYBOARD

OPERATION

MEC Access control can be integrated into a lock for emergency exit doors. Two potential free contacts (order x code) act on the block system.

The construction of the box is compact, IP66 vandal resistant and allows external mounting BOX

Input……….………………………12-24 V AC/DC +/- 10% Consumption…………………… 20 mA to 200 mA Connection duration……………..100% Working temperature……………- 30ºC to +50ºC Relay contacts………………… 2 commutted contact 1 = 5 A, 30 V contact 2 =1 A, 30 V programable type and timing.

12-13

The BIO-VEINZ reader uses a biometric scanner finger vein identification made by Hitachi for people identification

ACCESS CONTROL BIOMETRIC FINGERPRINT

All people have a unique and distinct arrangement of veins and capillaries of the fingers. In the enrollment phase, the finger is illuminated laterally by infrared sensor registers available optical source image and stores it in hardware, computer, or on a card depending on the configuration n of the system. Then, when used as access control or presence, the reader reads and compares the fingerprint image pre-registered or not registered and valid entry or presence.

OPERATION

Working temperature……..………………. 5ºC a + 45ºC Input ……………………………………….. 12 Vdc. Nr of fingerprints………………………….. 1000 Event memory…….……………………… 2000 Time zones……………………………….. 8 time zones (4 daily trams) Button input………………………………. Contact NA. / NC. Door contact input …..…….……………. Contact NA. / NC. Tamper ……………………………………. WallTamper and box tamper .

12-14

HANDLES

12-15

HANDLES: Door opening device combined with the panic bar that triggers the lock inserted into the leaf. It is installed on all our doors of a primary leaf and two leaves. DOORS EI2 The handle supplied as standard is the model M1 black. - According to DIN 18 255 - Alma steel - Diameter of handle: 20 mm or 23 mm. Fire handle DIN anti-anchor, fire-resistant polyamide with steel.

M 1

STAINLESS STEEL HANDLES

12-16

HANDLES: Door opening device combined with the panic bar that triggers the lock inserted into the leaf. It is installed on all our doors of a primary leaf and two leaves.

ANTIPANIC BAR

- Standard series bar of 1 to 3 points, closing doors to equip 1 and 2 leaves - Reversible - CE -Regulation EN 1125 rated

- Push series bar, 1-point closing doors to equip 1 or 2 leaves - Reversible - CE - Legislation rated EN 1125

STANDARD

PUSH

STAINLESS STEEL

12-17

STANDARD DOOR CLOSERS

The door closer is currently mandatory in all swing fire doors.

12-18

DATE & CHARACTERISTICS Adjustable clamping force EN (by means of changes in the position 2/3/4 of the support of the arm and of the body) Standard doors <1100mm. Similar version to left & right doors Arm forms page Weight 1,4 Dimensions in mm. Lenght 220mm. Thickness 45mm. Height 53,5mm. Closed speed independent Adjustable by means of two valves 180º -15º & 15º-0º.

SPECIAL DOOR CLOSER

A fully integrated 2 leaves on the edge of the door switch can integrate both the leaves and the electromagnet.

OPTION

One leaf with a design meant to go unnoticed for a volume built into the door. OPTION

12-19

Integrated perfectly thanks to the sausage of the same one inside the leaf of the door, remaining totally invisible.

OPTION

DOOR RETAINED

Spring strength 20N hasta 80N

Cushion material Silicone oil (temperature insensitive)

12-20

MEC retainer cushions the door closing, securing the right end of them.

DOOR OPENER EI STANDARD ELECTRIC FIREBREAK PORTER

Impact Resistence : 12000 N Heat Resistence: 2 h at 1150º EI 120

Under pressure opening: Approval by Norm UNE EN 1634-1

A 12 v AC 15 Kg.+- 10% Opening resistence 300.000

Fix lock Corrosive resistence UNI ISO 9227

Compliant with norm 89/336 EEC(EN55014)

of electromagnetic compatibility

SERIAL 24R

12-21

The electric door opener is a device that is installed on the door frame to control the opening from a remote location through an electrical device. In an installation of electronic door openers can activate the entry to the building and allowing access. An electric lock mechanism comprises a power and a shield or a cover depending if it's recessed or surface

Selectors end to install in the frame. Coordinates closing the double doors to prevent closing before the primary that the secondary and the door will not stay open, is now compulsory under the new legislation It is installed in the secondary door

CLOSER SELECTOR

12-22

CLOSING SELECTOR FOR RIM CONCEALED CLOSURE SELECTOR

GLASSES AND SPYHOLES

12-23

VISOR: accessory that allows for viewing across the room, installed in places where there is frequent traffic of people and the door should remain closed for security reasons

Certified maximum dimension 280 mm diameter circular spyhole

Maximum rectangular spyhole certified dimension 620 x 400 mm.

THERE ARE TWO KINDS OF VISORS

The EI2 glass windows are considered interior since become damaged and lose their properties if exposed to sunlight.

GLASSES & SPYHOLES EI 60 - 120

12-24

NOTE: EI2 60 & 120 spyholes can not be exposed to the sun or othr atmospheric agents

For EI 60 & 120 doorssets the minimum edge distance must be observed. See below for dimensions of standard EI 60 & 120 rated spyholes. See certificates pages for minimum dimensions of A & B.

H > 2050mm – C = 1550mm H < 2050mm – A = 300mm

H > 2050mm – C = 1550mm H < 2050mm – A = 300mm

EI 60 PYROBEL CIRCULAR SPYHOLE EI 120 PYROBEL CIRCULAR SPYHOLE

EI 60 PYROBEL RECTANGULAR SPYHOLE EI 120 PYROBEL RECTANGULAR SPYHOLE

280 Ǿ Integrity and insulation V18C 280 Ǿ Integrity and insulation V25C

300 x 400mm Integrity and insulation V14 600 x 400mm Integrity and insulation V16

300 x 400mm Integrity and insulation V21 600 x 400mm Integrity and insulation V23

SMOKE DETECTOR

When the smoke concentration exceeds a certain amount opening a potential free relay contact actuation of the electromagnet holding the door has both a temperature sensor that is triggered when it is over 65 º C. Electrical Connection 24 VDC Consumption 35 mA. Reaction to the smoke 0.2 dB / m Reaction of temperature sensor 65 º C Permissible load relay 24V / 1,0 A

12-25

POWER SUPPLY

For the use of smoke detectors, door opener and keyboards for fire doors, integrated power supply if the terminal is not enough, is the case in which you must use an external 24 VDC power supply provided as an additional source MEC locking system.

OPERATION

Electrical Connection ... ... ... ... ... ... ... ... ... ... ... ... .. 100 - 240 VAC / 46-63 Hz Consumption max. ... ... ... ... ... ... ... ... ... ... ... ... ... ... 0.8 A / 0.9 A / 1 A Output voltage ... ... ... ... ... ... ... ... ... ... ... ... ... ... ……24 VDC (+ / - 10%) Output Consumption ... ... ... ... ... ... ... ... ... ... ... ... .... 1.1 A / 2.7 A / 5 A Working temperature ... ... ... ... ... ... ... ... ... ... ……….- 25

to + 50 º C Protection ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... … ….IP 30 / just stays wet Housing ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. …..Stainless steel.

12-26

INTUMESCENTS JOINTS

The meeting intumescent MEC, this one lined with PVC self-adhesive and fireproof with a capacity of expansion from 1 to 10 from 120/130 º, The reaction to the fire M1 makes her not inflammable.

OPERATION

MODELO A B

2020 20 2

2720 27 2

3020 30 2

4020 40 2

12-27

MAINTENANCE

"Every fire door, being a security feature, you need a preventive maintenance, which maintain their properties unaltered in case of fire. Must be closed when required and, therefore, must be an accessory or system shutdown. The system should always work. "

The standard PRE UNE 23740 tells us about the installation, use and maintenance of fire doors

MECOSA has a maintenance both preventive and curative of fire doors, both for small industry and large companies. They are aware of the importance of maintenance, and the obligation to take good facilities

The maintenances must be realized by qualified personnel. PROCEDURE OF MAINTENANCE: 1.-State of the door. 2.-State of accessories. 3.-Funcionamiento of the door. 4.-Tiempo of usefulness +/-15 years. 5.-Periodicidad of the maintenance: Of generic form: 1 time a year for doors of particular use. 4 times a year for doors of intensive use. For his correct maintenance to realize it as Indicates in the manuals delivered with the doors.

12-28

M A I N T E N A N C E