IND 5626 Project Programming

Assignment 8 | Code Search

THE STANDARD

Waterlife Exploration & Boatel

Page 2: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Construction Type

Code Search

TYPE 1-A Fire Resistive (I) Non-combustible (A) (Structural elements are entirely of noncombustible or limited combustible materials. Wall enclosures may be masonry, steel, aluminum, glass, or other material.)

Building Construction Type & Occupancy

Occupancy classification

Occupancy load per floor ***Only one floor will be occupied

Sprinkler system

Mixed OccupanciesAssembly Group A-2 Restaurant (including associated commercial kitchens)Assembly Group A-3 MuseumGroup R-1 Hotels (transient)

Occupancy Load = Floor Area (SF) / Load Factor (SF)Group A-2 = 3,009 net / 15 = 200Group A-3 = 1,780 net / 15 = 119Group R-1 = 3,130 net / 200 = 16

The building is equipped with an automatic sprinkler system

Page 3: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Two exits minimum are required from the different spaces in your project. There are two exits existing in the project.

Minimum number of exits from different spaces

Maximum common path of travel distance

Maximum total travel distance to an exit

Minimum number of exits for each floor

Diagonal rule, minimum distance between exits

Minimum fire rating for exit access corridor partitions

The maximum common path of travel distance should be no more than 75’ with or without sprinklers.

The maximum travel distance to an exit should be no more than 250 feet.

Two exits minimum for each floor.

Distance apart equals to not less than ½ of the length of the maximum diagonal dimension of a space.

Group A-2 & A-3 partitions are permitted a fire-resistance rating of one hour with or without sprinklers. Group R-1 partitions are permitted a 0.5 fire-resistance rating sprinklers and aren’t permitted to have no sprinklers

Code SearchEgress

Page 4: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Less than 1 hour since it has less than four stories.

Minimum fire rating for exit enclosures

Minimum exit door size

Minimum width for level exit access corridor.

Project’s minimum width for vertical exit path

Minimum width of level exit access and exit corridors

Minimum width for vertical exit paths

Minimum exit corridor ceiling height

Maximum length of a dead-end corridor

Requirements for a smoke enclosure

Code Search

Exit doors should be no less than 76”.

Group A-2: 40”

Group A-3: 23.8”

Group R-1: 3.2”Exit doors should be no less than 32”.

The minimum required width of level exit access and exit corridors is 32 inches.

The minimum width for vertical exit paths is 44 inches for the Standard which occupies 50 or more occupants.

The minimum exit corridor ceiling height is 7 feet 6 inches high.

With or without corridors, it shouldn’t exceed 50’.

The minimum exit corridor ceiling height is 7’ 6” high.

Page 5: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Location of emergency lighting

Exit signage placement

Minimum exit sign illumination level?

Spacing and location requirements for sprinkler heads

Code SearchEmergency lighting must be provided at the door.

Signage should be located right in front of the door or adjacent to it.

The minimum exit sign illumination level is 0.1

Sprinklers must be located throughout the building with a maximum spacing of 15’ between sprinkler heads.

Page 6: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code Search

The maximum width is ½”

Regular doorway thresholds should have a maximum height of ½” above the landing or finished floor. Sliding doors should have a maximum height of ¾” above the landing or finished floor. Doorways with a floor level changes or raised thresholds more than ¼” should have a beveled edge with a slope no more than 50%.

Doors should either have a side-hinged or pivoted swing type. Doors should swing in the direction of egress travel. Doors should leave half of the corridor free while opened and in the case of a recessed door, it should only protrude a maximum of 7”.

Doors

What is the maximum width for an exit door (leaf)?

What are the threshold requirements for doors?

What are the door swing requirements for exits and exit corridors? –swing and at maximum opening protrusion?

Page 7: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code SearchStairs

Minimum headroom is 80”.

Maximum allowable height between landings is 12’.

Minimum landing requirement is 44” in length.

The riser heights are maximum is 7” and the minimum is 4”.

The minimum tread length is 11”.

The formula is: (2 x riser) + tread = 24” to 25”

Stairs

What is the minimum headroom for a stairway?

What is the maximum allowable height between landings?

What is the minimum landing requirement for a staircase with a straight run?

What are the maximum and minimum riser heights for a riser in a commercial project?

What is the minimum tread length in a commercial project?

What is the formula for determining the riser/tread relationship?

Page 8: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code SearchHandrails shall be continuous along both sides of the stairs. If handrails are not continuous, they shall extend at least 12” beyond the top riser and at least 12” plus the width of one tread beyond the bottom riser.

The top of handrail gripping surface shall be mounted between 34” and 38” above stair, ramp or flat walking surface.

Guardrail must have a vertical height of 42” from the upper surface of the top rail to floor, platform, runway, or ramp level.

Stairways overlooking another space require openings in the stair rail no more than 4” in any direction and open risers no taller than 4”.

The clear space between handrails and wall shall be 1 ½”.

Guardrails are required when there is a difference of 30” or greater between two upper and lower surfaces.

Handrails

What is the required handrail extension for a commercial stairway: Top of stairway? Bottom of Stairway?

What is the required stairway handrail height?

What is the required minimum guardrail height?

What are the requirements for maximum openings in handrails?

What are the requirements for handrails in relationship to the wall surface?

Is a guardrail required along with a handrail for stairways?

Page 9: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code SearchRamps

A ramp must have a width of at least 36” measured to the inside of the handrail.

There should be a ramp landing on both sides of the ramp run. The clear width of the landing should be at least as wide as the widest ramp run leading to the landing or have a minimum width of 60.” The clear length of the landing should have a minimum of 60”.

The maximum slope of a ramp in new construction is 1:12 however, in existing buildings the slope can have a minimum slope of 1:12. The maximum rise should be 30” and maximum run should be 30’.

Ramps

What is the minimum ramp width?

What are the requirements related to ramp landings?

What is the maximum slope for a ramp?

Page 10: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code Search

Class C is the maximum flame spread index.

Finishes

In a building equipped with sprinklers, what is the interior finish maximum flame spread index for enclosed vertical exits?

In a building equipped with sprinklers, what is the interior finish maximum flame spread index for other exitways?

What areas of your project will require compartmentalization?

What are the fire rated assemblies that separate them?

Class B is the maximum flame spread index exitways.

The exploratorium, workstations, administration area, the marketplace, and common areas.

The required fire rated assembly are non-combustible decorative materials suspended from walls or ceilings. It should be tested and meet flame propagation performance. Some of these can be through the NFPA 701, or NFPA 289.

Page 11: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code SearchAreas Materials Testing Requirements

Lobby TileTerrazoPaintGypsumConcreteWoodUpholstery

Class B: Steiner Tunnel Test/ASTMASTM C97/C97M/E84NFPA286 ASTM E2257 Class C: Steiner Tunnel TestRoom CorneNFPA/ < 30,000 double rubsr Test

Administration CarpetTileAcoustical tilePaintUpholsteryWoodGypsum

Pill Test /CFR 1630Class B: Steiner Tunnel Test/ASTMClass B: Steiner Tunnel Test/ASTM NFPA286 NFPA/ < 30,000 double rubsRoom Corner TestASTM E2257

Guest room Concrete GypsyumCarpetTilePaintUpholsteryWoodGypsum

Class C: Steiner Tunnel TestASTM E2257Pill Test /CFR 1630Class B: Steiner Tunnel Test/ASTMNFPA286 NFPA/ < 30,000 double rubsRoom Corner TestASTM E2257

Finishes

Page 12: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code Search Areas Materials Testing Requirements

Research Acoustic TilePaintUpholsteryVinylRubberWoodTileConcreteGypsum

Class B: Steiner Tunnel Test/ASTM NFPA286 NFPA/ < 30,000 double rubsASTM D6413/Room CorneN/ARoom Corner TestClass B: Steiner Tunnel Test/ASTMClass C: Steiner Tunnel TestASTM E2257

Aquarium Acoustic TilePaintUpholsteryWoodVinyl RubberTileConcreteGypsum

Class B: Steiner Tunnel Test/ASTM NFPA286 NFPA/ < 30,000 double rubsRoom Corner TestASTM D6413/Room CorneN/AClass B: Steiner Tunnel Test/ASTMClass C: Steiner Tunnel TestASTM E2257

Common Areas Acoustic TilePaintUpholsteryWoodCarpetTileGypsum

Class B: Steiner Tunnel Test/ASTM NFPA286 NFPA/ < 30,000 double rubsRoom Corner TestPill Test /CFR 1630Class B: Steiner Tunnel Test/ASTMASTM E2257

Finishes

Page 13: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code SearchAny building that is more than three stories high or in which the vertical distance between the bottom terminal landing and the top terminal landing exceeds 25 feet must be constructed to contain at least one passenger elevator that is operational and will accommodate an ambulance stretcher 76” long and 24” wide in the horizontal position.

Accessible elevators shall be on an accessible route.

The elevator should provide enough space for a wheelchair to enter and maneuver around comfortably. The minimum ADA door width is 36”. The depth of the car must be at least 51” and the width must be at least 68”.

Call buttons for elevators should be at 42” from floor. The hall lantern should be at least 72” above floor finish. Elevators should be equipped with Braille on call and level (inside elevator) buttons as well as on signage on elevator door jamb.

Elevators

Elevator requirement?

Elevator locations should be?

What is the minimum elevator width?

What are the minimum inside dimension for elevators?

What are the code and ADA requirement for elevator buttons and signage?

Page 14: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code Search

There are 5 restrooms in our project. 1 per 50 water closets are required for males and females.

1 per 50 lavatories are required for males and females.

The required sq. footage related to the toilet and accessibility lavatory is 500 sq. feet.

Horizontal sidebar 42” minimum length, placed 12” max from the back wall. Horizontal backbar 36” minimum length, placed 12” minimum from centerline of toilet. Both horizontal bars should be placed at a height between 33”-36”. Vertical grab bar 18” minimum length, placed between 39”-41” from back wall at a height between 39”-41”

Toilet Rooms

How many toilets are required for your project?

How many lavatories are required for your project?

What are the sq. feet requirements related to the toilet and accessible lavatory?

What are the grab bar requirements for the toilet?

Page 15: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code Search

Minimum stall width: 60” measured perpendicular from the side wall. Height range for toilet seat: 17” minimum and 19” maximum measured to the top of the seat.

The centerline of the toilet should be 16” minimum to 18” maximum from the side wall or partition.

A 5’ turning radius is required for a rotating wheelchair.

Doorwars should be at least 32” wide.

Toilet Rooms

What is the minimum stall width? (non-ADA accessible) What is the height range for a toilet seat?

How far should the centerline of a toilet be from the side wall?

What is the minimum wheelchair turning radius (unobstructed) requirement?

Entry doors for a toilet stall must be how wide?

Page 16: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code Search

1 service sink is required for our project.

1 per 100 drinking fountains are required for our project.

For a standing person, the height of a drinking fountain should be between 38” minimum and 43” maximum above finished floor. In order to be wheelchair accessible, a drinking fountain spout should not be higher than 36”

Miscellaneous

How many service sinks are required for your project?

How many drinking fountains are required for your project?

At what height do the drinking fountains need to be located?

Page 17: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code SearchSpecial Features

Media Room Sales and Service Counter

Line of sight over/between the heads of spectators

Line of sight over/between the heads of standing spectators

Check-Out Aisle Counter

Alteration of sales and service counter

Page 18: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code SearchSpecial Features

Kitchen

Pass through kitchen U-shaped kitchens

Storage

Page 19: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code SearchSpecial Features

Bathtubs

Tubs may have shower seats, but it’s not required.

Page 20: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Code SearchSpecial Features

Showers

Page 21: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsSpace Allowance and Reach Ranges

Unobstructed forward reach Obstructed high forward reach

Unobstructed side reach Obstructed high side reach

Page 22: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsEntrances

Width of wheelchair spaces

Depth of wheelchair spaces

Page 23: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsAccessibility Routes

Clear width of an accessible route

Clear width at turn

Page 24: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsProtruding Objects

Limits of protruding objects Post-mounted protruding objects

Vertical clearance

Page 25: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsGround and Floor Surface

Ramp landings

Ramps

Extended floor or ground surface edge protection

Page 26: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsDoors

Maneuvering clearances at manual swinging doors

Page 27: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsDoors

Clear width of doorway

Maneuvering clearances at doorways without doors, sliding doors, and folding doors

Maneuvering clearances at recessed doors

Doors in series

Page 28: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsDrinking Fountains & Water Coolers

Drinking fountain spout locationSpout height and knee clearance

Clear floor space

Freestanding fountain or cooler

Built-in fountain or cooler

Page 29: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsWater Closets

Water closet location Size of clearance at water closet

Wheelchair accessible toilet compartment toe clearance

Size of wheelchair accessible toilet compartment

Height and depth of urinals

Urinals

Stalls

Page 30: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsLavatories and Mirrors & Sinks

Lavatory clearance Clear floor space at lavatories

Page 31: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsSignage

Height of raised character

Braille dimension and measurements

Position of braille

Location of tactile signs at doors

Pictorial field

Page 32: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsHandrails, Guardrails, & Grab Bars

Handrail height Handrail clearanceHorizontal projection below gripping surface

Top and Bottom handrail extension at ramps

Handrail non-circular cross section

Side wall grab bar at water closet

Rear wall grab bar at water closet

Page 33: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

ADAAG DrawingsFixed or Built-In Seating and Tables

Page 34: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Universal Design PrinciplesEquitable Use The design is useful and marketable to any group of

users

● Provide all users with the same means of use: identical if possible; equivalent when not.

● Avoid segregating or stigmatizing any users.● Security, safety and protection requirements should

be applicable to all users equally● Make the design appealing to all users.

Flexibility of Use

Simple and Intuitive

The design accommodates a wide range of individual preferences and abilities

● Provide choice in methods of use.● Accommodate right-or-left-handed access and use.● Facilitate the user’s accuracy and precision.● Provide adaptability to the user’s pace.

Use of design is easy to understand● Eliminate unnecessary complexity● Be consistent with user expectations and intuition.● Accommodate a wide range of literacy and

language skills.● Arrange information through its level of importance

Page 35: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Universal Design Principles

Perceptible Information

Tolerance for Error The design minimizes hazards and the adverse consequences of accidental or unintentional actions

● Arrange elements to mitigate hazards and errors: most of the elements used, most accessible; remove, separate, or cover hazardous elements.

● Provide warning of hazards and errors.● Provide fail safe features.● Discourage unconscious action in tasks that require

vigilance.

The design communicated necessary information effectively to the user

● Use various ways (pictorial, verbal, tactile) to present repetitive vital information.

● Provide sufficient contrast between vital information and its surroundings.

● Maximize “legibility” of vital information.● Differentiate elements in ways that can be described

(i.e., make it easy to give instructions or directions).● Provide compatibility with a variety of techniques or

devices used by people with sensory limitations.

Page 36: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

Universal Design Principles

Low Physical Effort

Size and Space for Approach and Use Appropriate Size and Space is provided for approach and use

● Provide a clear line of sight to important elements for any seated or standing user.

● Make it easy for any sitting or standing user to reach all components.

● Accommodate variations in hand and grip size.● Provide sufficient space for the use of support or

personal assistance devices.

The design can be used efficiently and comfortably

● Allow user to maintain a neutral body position.● Use reasonable operating forces.● Minimize repetitive actions.● Minimize sustained physical effort.

Page 37: THE STANDARD€¦ · Mixed Occupancies Assembly Group A-2 Restaurant (including associated commercial kitchens) Assembly Group A-3 Museum Group R-1 Hotels (transient) Occupancy Load

CitationsReferencesInternational Building Code. (2017). 2017 Florida Building

Code (6th ed.). Retrieved from

https://codes.iccsafe.org/content/FBC2017

Jenkins, S., Rothfield, K., (n.d.). ADA guidelines.

The Center for Universal Design. (1997). The principle of

universal design (2nd ed.). North Carolina State

University. Retrieved from

https://projects.ncsu.edu/ncsu/design/cud/about_ud/

udprinciplestext.htm.

U.S. Architectural and Transportation Barriers Compliance

Board. (2002). Americans with Disabilities Act

(ADA) accessibility guidelines for buildings and

facilities. United States Access Board. Retrieved

from

https://www.access-board.gov/guidelines-and-stand

ards/buildings-and-sites/about-the-ada-standards/b

ackground/adaag.

United States Access Board. (2004). Americans with

Disabilities Act and Architectural Barriers Act

Accessibility Guidelines. Retrieved from

https://www.access-board.gov/attachments/article/4

12/ada-aba.pdf

Figures

Figure 1: Image in courtesy of Adam Hernandez