7
Mach M5 LED Mach M3 LED Mach video transmission system The LED revolution LED OT-light systems for surgery LED OT-LIGHTS

The LED revolution - Vivimedi LED 5-3_small.pdf · The LED revolution Dr. Mach GmbH & Co. KG Subject to change without notice due to technical modification · 59000268 A01 · Version:

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: The LED revolution - Vivimedi LED 5-3_small.pdf · The LED revolution Dr. Mach GmbH & Co. KG Subject to change without notice due to technical modification · 59000268 A01 · Version:

Mach M5 LEDMach M3 LEDMach video transmission system

The LED revolution LED OT-light systems for surgery

L E D O T - L I G H T S

Page 2: The LED revolution - Vivimedi LED 5-3_small.pdf · The LED revolution Dr. Mach GmbH & Co. KG Subject to change without notice due to technical modification · 59000268 A01 · Version:

New highlights in the OT

2

Dr. Mach sets standards in the medical

illumination technology for decades.

The new OT-light generation with LED

technology supports your professiona-

lity by innovative technology and

design.

The advantages of the LED technology:

adjustable light colour, a life-span of

minimum 25.000 hours and an almost

nonexistent heat development in the

surgeon’s head area and in the wound

field.

The advantages already provided by

Dr. Mach’s light technology with

halogen and gas discharge lamps have

been maintained: natural colour

reproduction, exact illumination of the

wound field and easy positioning of

the light head.

Your Team

2 3

Page 3: The LED revolution - Vivimedi LED 5-3_small.pdf · The LED revolution Dr. Mach GmbH & Co. KG Subject to change without notice due to technical modification · 59000268 A01 · Version:

Changing the light colour The use of different coloured LED’s makes it possible for the first time in surgery to change the light colours depending on the application.

Five different colour temperature values can be set at the key pad on the lamp housing: 3750, 4000, 4250, 4500 and 4750 Kelvin.

The surgeon has the possibility to choose the optimum OR light according to the tissue type and the wound field texture.

Superiour colour renditionWith a previously unattainable colour rendition R

a = 95 and R

9(red) ≥ 90 you

easily see the tiniest nuances of colour in tissue. For recognizing the exact colour spectrum of the wound the exact rendition of the red colour range is essential. R

9(red) ≥ 90 means for the surgeon a visibly better recognition of details. The

colour spectrum of the wound is rendered naturally with rich contrast. The OT-light clearly provides welcome relief for your eyes.

Integrated OT-laser pointer The built-in laser pointer always indicates the middle of the light field and helps the surgeon to find the optimal position of the OT-light to the wound field.

Advantages LED technology

Colour composition inside the light head Dr. Mach already merges the different coloured LED’s by a computer-calculated optical system and facetted lenses.

This means: The composed light leaves the optical system as white light and is dispersed over the wound field homogeneously.

Colour shadows in the light beam of the OR light caused by the surgeon’s head, shoulder or hands are avoided by the colour composition in the opti-cal system.

Facetted multi-lens system A multitude of computer-calculated facetted lenses guarantees homogeneity and lowest shadiness in the light field.

Forty separately arranged optical systems, each with four LED modules, generate their own light field, which increases the contrast effect of the OR light. The maximum light intensity is 160.000 Lux.

Illumination in depthYou have the possibility to increase the light intensity of the central segment of the OT-light. This enables an optimum illumination of the wound field according to its texture and the shadowing effects.

This is very important in case of small and deep wound channels.

4 5

3750 Kelvin 4250 Kelvin 4750 Kelvin

Conventional lighting systems Dr. Machlight system

R9-valuesbetween20 und 70

Ra-valuesbetween50 und 95

R9 ≥ 90

Ra = 95

light guide

Page 4: The LED revolution - Vivimedi LED 5-3_small.pdf · The LED revolution Dr. Mach GmbH & Co. KG Subject to change without notice due to technical modification · 59000268 A01 · Version:

Mach M5 LED

Mach M3 LED

6 7

The new ones: Mach M5 LED / Mach M3 LED

Page 5: The LED revolution - Vivimedi LED 5-3_small.pdf · The LED revolution Dr. Mach GmbH & Co. KG Subject to change without notice due to technical modification · 59000268 A01 · Version:

8 9

Mach M5 LED

Mach M3 LED

Mach M5 LED

Mach M3 LED

The new ones and their combinations

Technical data Mach M5 LED Mach M3 LED

Light intensity Luxat 1 meter distance 160.000 130.000

Colour rendering index Ra(1) 95 95

Colour rendering index R9(red)(2) ≥ 90 ≥ 90

Focussable size of the light field (in cm) 20-32 22

Colour temperature (Kelvin) 3750, 4000, 4250, 4500, 4750

3750, 4000, 4250, 4500, 4750

Electronic light intensity controlat the lamphead standard standard

Dimming range 50 - 100 % 50 - 100 %

Temperature increase in head area 0,5° C 0,5° C

Total power consumption 160 W 120 W

Number of LED´s 160 112

Life-span of the LED´s > 25.000 h > 25.000 h

Working distance (in cm) 60 - 150 60 - 150

Height adjustment (in cm) 118 118

(1) Ra is an average of R1 = burnt pink, R2 = mustard yellow, R3 = yellow green, R4 = light green, R5 = turquoise blue, R6 = skyviolet, R7 = violet, R8 = lilac. Maximum value = 100.

(2) R9 ist the value for the rendering of the colour red. This is not used in cal- culating the general colour rendering index Ra. The values for conventional operating lights are between 20 and 70. Maximum value = 100. Values of more than 90 allow the surgeon to recognise details better in the wound area.

Combination M5/M5 LED

Dim

ensi

on

s in

mill

imet

er

Combination M5/M3 LED

Combination M3/M3 LED

Page 6: The LED revolution - Vivimedi LED 5-3_small.pdf · The LED revolution Dr. Mach GmbH & Co. KG Subject to change without notice due to technical modification · 59000268 A01 · Version:

Local intranet (LAN)

Operating light with digital video system in the operation-theatre

Beamer in the auditorium 2

Beamer in the auditorium 1

PC 1

Router

PC 2

PC 3

Internet

Camera remote control

• 72-fold zoom• focus-control (automatic/manual)• iris-control (automatic/manual)• colour-control• frozen image• optional with image rotation

A Sony camera with 72-fold zoom, autofocus, autoiris and image rotation is used. Via remote control panel it can be controlled at the same time from an auditorium or other rooms.

Digital video systemBy a new digital camera remote control you can now receive digital video signals for the computer or network. Analog camera images are converted in MPEG4-video signals. These are available through a RJ45 interface at the remote control and a network cable.

Advantages: You don´t need a video card any longer. The images can be directly saved on the computer if sufficient capacity is available. Nevertheless you can further record the signals on video or DVD-recorders. For this the remote control panel is equipped with two S-video (Y/C) connectors.

Available digital video systemsVideo system DIGITAL ECOEvery computer in the netwotk has access to the video images and they can be saved on a hard disc drive of sufficient capacity.

Video system DIGITAL PC-CONTROLAs with the video system Digital Eco every computer in the network has access to the video images and they can be saved on a hard disc drive of sufficient capacity. Additionally the camera can be controlled by a specially designed software through the PC-screen. This is done by an IP-address designated for the camera remote control.

10 11

Advantages Ergonomics

Modulated video- and control signalsThe video- and control signals are not transmitted in the conventional way by separate cables – but via the electric lines and sliding contacts of the operating light.

Advantages:The operating light permits continuous rotary movement.The upgrading with a camera is significantly cheaper and easier.The camera doesn´t need readjustment dependig on the distance between lamphead and wound area as it is positioned almost centrally in the lamp-head.

Flow propertiesDuring development high attention was paid to the performance of the new LED OR lights in laminar-flow ceiling systems. The open ring form and the minimal surface avoid any heat increase in the surgeon’s head area and cre-ate a perfect laminar flow performance, being a basic hygienic requirement in surgery.

Key pad on the lamp housingSeveral light functions can be adjusted electronically, such as:• Switching ON and OFF• Illumination in depth• Laser pointer• Merging of light fields (focussing)• Electronic light intensity control• Changing the colour temperature: 3750, 4000, 4250, 4500, 4750 K

Cool lightThe LED technology is much more effective than conventional light sources such as halogen bulbs. The heat radiation is reduced to a minimum without using any expensive filter technique.The temperature increase in the surgeon’s head area is almost nonexistent.

Long life-spanThe life-span of more than 25.000 operating hours reduces the costs for exchanging and replacing the illuminants considerably, compared with the conventional halogen technology used with former OT-lights.

Technical data

Dr. Mach camera MFB-MO(1) OFB-ST(2)

Colour image camera for visual communication (PAL/NTSC)

Objektiv systems

72-fold zoomf = 4.1 bis 73.8 mmF1.4-3.0Auto Focus(integr. focussing system)

72-fold zoomAuto Focus(integr. focussing system)

Video exit75 Ohm

VS1.0 Vp-p.Sync. NegativC: Burst 0.300 Vp-pVBS: 1.0 Vp-pComposite

VS1.0 Vp-p.Sync. NegativC: Burst 0.300 Vp-pVBS: 1.0 Vp-pComposite

Image points 752 (H) x 582 (V) 752 (H) x 582 (V)

Horizontal resolution Over 460 lines Over 460 lines

Vertical resolution Over 400 lines Over 400 lines

Humidity 20 - 85% 20 - 85%

Dimesions(Ø, Length) 80 x 150 mm 80 x 150 mm

Weight 900 g 900 g

Interference radiation in acc. with FCC class A FCC class A

(1) with remote control, with image rotation(2) without remote control, without image rotation

No additional cables are needed for the camera.By a special electronic design the power supply of the operating light isused for the transmission of the control- and video signals.

For detailed informations please ask for our special catalogue for singlelights.

Integrated video system

N E W

Page 7: The LED revolution - Vivimedi LED 5-3_small.pdf · The LED revolution Dr. Mach GmbH & Co. KG Subject to change without notice due to technical modification · 59000268 A01 · Version:

Seite 16

The

LED

revo

lutio

n

Subj

ect

to c

hang

e w

ithou

t no

tice

due

to t

echn

ical

mod

ifica

tion

· 590

0026

8 A

01 ·

Vers

ion:

06/

2007

Dr. Mach GmbH & Co. KG

Flossmannstraße 28 · D-85560 EbersbergPhone: +49 (0) 8092 / 20 93-0 · Fax: +49 (0) 8092 / 20 93-50www.dr-mach.com · e-mail: [email protected]