24
The Challenge How to eliminate the inherent inaccuracy of tote tanks?

The Challenge How to eliminate the inherent inaccuracy of tote tanks?

  • Upload
    marika

  • View
    22

  • Download
    1

Embed Size (px)

DESCRIPTION

The Challenge How to eliminate the inherent inaccuracy of tote tanks?. The Solution. ELIMS. 6500 Gallon 10ft. X 12ft. Bulk Poly Tank. The foot print of 5 Poly Tanks is the same as a single 500 bbl. Frac Tank. Proposed Equipment. vs. Existing Equipment. ONE POLY TANK REPLACES 20 TOTES. - PowerPoint PPT Presentation

Citation preview

Page 1: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

The Challenge

How to eliminate the inherent inaccuracy of tote

tanks?

Page 2: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

6500 Gallon 10ft. X 12ft. Bulk

Poly Tank

The Solution

ELIMS

Page 3: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

The foot print of 5 Poly Tanks is the same as a single 500 bbl. Frac Tank

Page 4: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

ONE POLY TANK REPLACES 20 TOTES

Existing Equipment

Proposed Equipment

vs

Page 5: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Additional Benefits

Real time on-site field inventory management

Fewer man-hours in the field and in the yard (approx. $6,000.00 / job)

Reduced trailer fleet rental expense (approx. $5,500.00 / job)

Reduced third party hauling/demurrage (approx. $8,000.00 / job)

Eliminate tote disposal cost (approx. $10,500.00 / job)

Eliminate partial tote handling, consolidation, risk of contamination

Reduced risk of tote connection spills (environmental & safety concerns)

On-site end of job print out of chemical totals

Eliminate inventory adjustments & write offs (100% savings / job)

Page 6: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

ELIMS at work

Page 7: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

inlet assembly

outlet assembly

Poly Tank Connections-3” Inlet and Outlet provide ideal flow characteristics

-Check Valves on both sides

- The latest configuration has a 90 degree fitting that alleviates space issues and allows more configuration

options

Page 8: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Poly Tank Level Monitoring

Wireless Communication to each individual tank (up to 16) within 400 feet line-of-sight

Master Monitoring Panel is a portable self contained unit that allows for the local level and real time monitoring of each individual tank.

Page 9: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Logged totals can be printed after each stage or at the end of the job. Printouts can be all totals, totals per tank, present stage totals or totals for all stages.

Page 10: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

ELIMS can be utilized to monitor fluid level in any container the customer needs.

Page 11: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Master Monitoring Panel Display

4000 gal. 3000 gal. 300 gal.

4500 gal.5000 gal. 4500 gal.

CLAYMAX SURFACTANT SURFACTANT

FR X-LINKERFR

1

Page 12: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Monitor the progress from any desktop or laptop computer with Internet connection

Off Location Remote Monitoring

Page 13: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Satellite Communications

Improved communication technology has allowed ELIMS

to maintain website access to in-field data without cell service

coverage.

Geostationary Earth Orbit satellites eliminate issues with

satellite connectivity experienced in the past.

Page 14: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Solids Monitoring

ELIMS has the ability to monitor bulk solids as well.

Seamless integration into the ELIMS system adds the capability for ELIMS to monitor all consumables on any frac site.

Page 15: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

3D Solids Monitoring

The sensor technology adds 3D mapping of the solid volume which can be converted

into a weight figure if desired.

Multiple 3D heads can be outfitted to solids containers to ensure every compartment is monitored with an accuracy near 1% while

consuming.

Page 16: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Safety Valve- Automated- Electronicaly Actuated - Programmable- Manual Over-Ride- Remote Over-Ride- Alarm Indicator

- The Safety Valve is programmable with customer determined set points.

- Set points are entered into the touch screen monitor and can be adjusted, over-ridden, and/or eliminated at any time.

- Alarm Indicators are shown on the monitor allowing the customer to diagnose and repair the issue as quickly as possible.

Page 17: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

All remote data can be viewed via an Internet connection by logging in at http://www.elims.com

Page 18: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Each user will be provided a user name based on their email address and a temporary password that can be changed by the user at any time.

Page 19: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Current tank levels and historical data can be viewed in multiple formats.

Page 20: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

A database of historical pumping volumes is compiled at the end of every job and is accessible by authorized users on the website at zero cost.

Page 21: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Job History to Date

Jobs that have used ELIMS: 44

Jobs that have used ELIMS successfully: 44

Crews currently running ELIMS: 7

Stages completed using ELIMS: 533

Pumped gallons monitored by ELIMS: 400,000+

Potential error savings: 32,000 gallons and countless hours of labor

Page 22: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Chemical Usage

Types of chemicals being used to date:- Clay Control- Low pH buffer- High pH buffer- Guar Gel- Delayed Borate X-Linker- Instant Borate X-Linker- FR- Surfactant- Gel StabilizerChemicals and solids planned for future use:- Breaker- Scale Inhibitor- Acids - Acidizing Chemicals- Water- Frac Sand- Dry Guar

Page 23: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

Areas of Operations

Current Operations:

Main Operations and Production Facility – Houston, Tx

Field Technician – Kilgore, TxBulk Storage Facility (Soon)– Waskom, Tx

Field Technician – Pleasanton, TxBulk Storage Facility – Karnes City, Tx

Warehousing Facility – Midland, Tx

Planned Areas of Expansion:

UticaEagle FordHaynesville

Williston BasinMarcellusWolfberryNiobrara

Page 24: The Challenge How to eliminate the inherent inaccuracy of tote tanks?

The new cost effective and safe way to monitor your consumables in the field, office, mobile phone, home, deer stand, or anywhere an internet connection is available.

The ELIMS solution