8
| Temperature | Humidity | Dew Point | | Pressure | Flow | Air Velocity | | CO, CO2, PM2.5 | Signal Meter | Based on ISO 9001:2015Calibration Lab ILAC ISO/IEC 17025 Factory Automatic QC Inspection System IEC 61298

Temperature | Humidity | Dew Point | | Pressure | Flow ...€¦ · 04/10/2019  · 2019-eYc-Measuring-specialist-Brochure_20191001 Created Date: 10/4/2019 2:31:46 PM

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Temperature | Humidity | Dew Point | | Pressure | Flow ...€¦ · 04/10/2019  · 2019-eYc-Measuring-specialist-Brochure_20191001 Created Date: 10/4/2019 2:31:46 PM

| Temperature | Humidity | Dew Point || Pressure | Flow | Air Velocity || CO, CO2, PM2.5 | Signal Meter |

Based on ISO 9001:2015‧Calibration Lab ILAC ISO/IEC 17025 Factory Automatic QC Inspection System IEC 61298

Page 2: Temperature | Humidity | Dew Point | | Pressure | Flow ...€¦ · 04/10/2019  · 2019-eYc-Measuring-specialist-Brochure_20191001 Created Date: 10/4/2019 2:31:46 PM

THM06with

Display

THM06

AFMS-160AFMT

PHM33

Leapfrog Your Competition in

Page 3: Temperature | Humidity | Dew Point | | Pressure | Flow ...€¦ · 04/10/2019  · 2019-eYc-Measuring-specialist-Brochure_20191001 Created Date: 10/4/2019 2:31:46 PM

THS88PlusSD05

THS88Plus

FTM09

DPMF-M9

Industrial Measuring Market.

Page 4: Temperature | Humidity | Dew Point | | Pressure | Flow ...€¦ · 04/10/2019  · 2019-eYc-Measuring-specialist-Brochure_20191001 Created Date: 10/4/2019 2:31:46 PM

• Input : Capacitive humidity sensor & Pt 100Ω• Measuring range : -40°C ... +120°C ; Customized up to 150°C (Optional) ; 0 ... 100%RH (non-cond.) -50 ... +60dp°C• Signal connection : 4 ... 20mA / 0 ... 10V / RS-485/3-wire• Accuracy : Temp. : ±0.15°C+0.002°C x t actual Humidity : 0 ... 100%RH (non-cond.) Dew point : ±3dp°C ± (0.02%F.S./°C)• IP Rating : IP67• Applications : Semiconductor / Electronics / Steel Industry / Food / Chemical / Pharmaceutical / Biotechnology Industry / Tobacco Industry

• -40 ... + 200 ℃ ; 0 ... 100 %RH ; 10 bar• Analog output / RS-485 ( Programmable )• Accuracy : Humidity : ± 1.2 %RH ; Temp. : ± 0.15 ℃ ± 0.002 ℃ x tactual• Dew point, absolute humidity etc ...• IP Rating : IP65• Application : Semiconductor / Pharmaceutical / Industry

• Input type : Capacitive Humidity Sensor & Pt100Ω class A• 0 ... + 50 ℃ ( THS301 ) ; -40 ... +80 ℃ ( THS302 / 304 / 307 ) ; 0 ... 100 %RH;Proof pressure : 10 bar• Analog output / RS-485 ( Programmable )• Accuracy : Humidity : ± 2 %RH; Temp. : ± 0.2 ℃ ± 0.005 ℃ x t actual• Application : Laboratory / Pharmaceutical Outdoor Temp. / Humidity monitor

Industrial Multi-Function Dew point Transmitter

‧Anti-condensation sensor‧Bearable pressure 16 bar‧3-kind connectors

SD05 IntegratedSignal Indicator

High Pressure Dew Point Transmitter

• Speed Upgrade 150%• Max. scaling range : -100 ... +60 dp °C ( reference )• Linear accuracy ( Operation range of dew point : -60 ... +60 dp°C ) : ±2 dp°C (at +25 °C ± (0.02%F.S/°C)• Capacitive humidity sensor & Pt100 Ω• Pressure resistance : 16 bar• Analog output / RS-485 (Programmable) • Signal connection : 3-wire• Power supply : 8 ... 35VDC/10 ... 30VAC• IP rating : body IP65 (probe : IP20)• Material : SUS304• Application : CDA system / Desiccant Rotor / Rotor dehumidifier / Refrigeration Dryers / Adsorption Air Dryer

Recommend

Temperature / Humidity / Dew Point

Preliminary

Most Economical

Provide additional option(ILAC/TAF) test report.

Page 5: Temperature | Humidity | Dew Point | | Pressure | Flow ...€¦ · 04/10/2019  · 2019-eYc-Measuring-specialist-Brochure_20191001 Created Date: 10/4/2019 2:31:46 PM

3-Cycle curve

Wind

veloc

ity (m

/s)

Time (Sec)

0

10

20

30

40

50

60

70

0 100 200 300 400 500 600 700 800 900

Standard wind speed#102 Digital wind speed#53

• Micro-corrosion water and air measurement• Strong housing with analog and RS-485 output• Type : Resistance Temperature Detector• Range : Air : 0 ... 60 m/s• Output Signal : Analog : 4 ... 20mA / 0 ... 10V ; RS-485• Product Accuracy ( at 25°C ; 50 ... 60%RH ) : Air : 3% < 60 m/s• Power Supply : 8 ... 35 VDC

For water

Hot Wire Thermal Flow Transmitter

FTM09

● Lattice OLED / Gas,Natural gas, Pulse / 4-20mA / RS-485 / 2-Wire / 3-Wire● Pt20 / Pt1000 ; Pt20 / Pt300 / Accuracy : 1.0% ; 1.5% ; 2.0%/Customized service

Thermal mass gas flowmeter controller

Dew Point / Gas / Air velocity / Flow

Preliminary

Comingsoon

Thermal Air Velocity Transmitter

Inserted into the diameter 1/2

• -50 ... +80 ℃ / -50...+60 dp℃• Analog output / RS-485 ( Programmable )• Accuracy : Dew point : ± 3 dp ℃ ± ( 0.02%F.S./℃ ); Temp. : ± 0.15 ℃±0.002 ℃ x tactual Frost point, absolute humidity etc ...• Application : Industrial process / Pharmaceutical Industry

Provide additional option(ILAC/TAF) test report.

Page 6: Temperature | Humidity | Dew Point | | Pressure | Flow ...€¦ · 04/10/2019  · 2019-eYc-Measuring-specialist-Brochure_20191001 Created Date: 10/4/2019 2:31:46 PM

• Measurement accuracy 1 %• Medium Temp. -30 ... +160 ℃ Flow range : 0 ... ± 10 m/s• RS-485, Modbus, 4...20mA, Relay OCT pulse• Converter IP67, transducer IP68• Wide measurement range , pipe size from DN15mm to DN6000mm• Connect the Temp. transducer can finish the heat / energy measurement

• Multiple input types : Pressure, Differential Pressure, Temp., Flow, etc. / 2-wire loop design / Anti-interference design / IP67

Wall Mounted Ultrasonic Flowmeter

FUM05B

• Measuring range : 0.1 ... 25bar• Pressure type : Differential pressure• Accuracy : ±0.075%FS; ±0.1%FS (typ.);±0.2%FS• Type : Differential Pressure• Power output : 4 ... 20mA、 4 ... 20mA+HART®(10.5 ... 36V, Typical 24V)• Static pressure ran : 70bar、250bar、400bar• IP Rating : IP65

P064

Digital Differential Pressure / Pressure Transmitter

• Measuring range : -1 ... 400bar• Pressure type : Relative pressure, absolute pressure• Output signal / Power supply : 4 ... 20mA, 0 ... 5V, 0 ... 10V(12 ... 30VDC) / 0.5 ... 4.5V R/M(5VDC)• Accuracy : ±0.5%F.S.(typ.)• Response time : < 4ms• Ambient Temp. : -20 ... 80°C• IP rating : IP65

P046

OEM Piezoresistive Pressure Transmitter

• Measuring range : 0 ... 10 bar(L051/53) / 0 ... 20 bar(L054)• Accuracy : 0.5% F.S.(L054) / ± 0.5% F.S.• output : 4...20mA(L051)• Signal Connection : 2-wire• Cable length : 3 ... 102m(Customization)• IP rating : IP68• With eYc SD03 to Real-time display the liquid level data.

L051/L053/L054

Submersible Pressure / LevelTransmitterFlow Meter

DPMF-M9

• Output:Analog / RS-485 / Switch• Input:Analog / Pulse• Accuracy:±0.2%FS. frequency : ±1 pulse (LMS), better than 0.2%• Measuring Range:-999999 ... 999999 for instantaneous flow; 0 ... 99999999.9999 for totalizer• Power supply : AC80 ... 220V ; DC24V±1V• Power consumption : ≦ 10w

• Type : PTC thermistor / Resistance Temperature Detector (RTD)• Output : PNP, NPN, Relay• Measuring range : Water : 1 ... 200 cm/s ; Oil : 3 ... 300 cm/s Gas Flow : 20 ... 2000 cm/s• Supply supply : 24 ± 10 %VDC ; IP67• Current consumption : ≦ 60 mA• Operating temperature : -20 ... 85 °C• Application : Venting systems / Hydraulic

Coriolis Mass Flow Meter

FCM06

Air velocity / Flow / Pressure / Signal / Meter

• Communication interface : RS-485• Flow range : 5 ... 200,000 kg/h• Accuracy : Up to ±0.1%• 20 : 1 turndown ratio• Process temperature : Up to +250°C Operating pressure : Customized• Mass flow, density, temp. & volume flow can be measured at the same time• Output : 4 ... 20mA /Pulse • Power supply : 85 ... 265 VAC 50 / 60Hz, 18 ... 36 VDC / Repeatability : ±0.05%

• Measuring range : 10 m/s ; 20 m/s;0 ... 10 V• Accuracy : ± 5 % of F.S.• Signal connection : 3-wire• Economical type• Application : HVAC air process / Clean room / Laminar flow

Provide additional option(ILAC/TAF) test report.

Page 7: Temperature | Humidity | Dew Point | | Pressure | Flow ...€¦ · 04/10/2019  · 2019-eYc-Measuring-specialist-Brochure_20191001 Created Date: 10/4/2019 2:31:46 PM

Signal Display MonitorSignal Converter

DMB04

SubmersiblePressure

PiezoresistiveDifferential

PressureTemperaturePiezoresistive

Pressure

SD06-L SD06-MPSD06-P SD06-T

SD06 Integrated Indicator Transmitter Series• Input : Temp. / Pressure / Differential pressure / Level • Measuring range display : -9999...99999 • Linear accuracy :<0.2% / Output : 4...20 mA / IP67• Application : Industrial Process Control /Laboratory Systems / Compressor

SD03 ( Indicator )

• Multiple input types : Pressure, Differential Pressure, Temp., Flow, etc. / 2-wire loop design / Anti-interference design / IP67

SD03+L051(Submersible Pressure Transmitter)

• Sensor : Submersible Pressure Transmitter• Measuring range : 0 ... 10 bar• Output : 4 ... 20mA ; 2-wire ; IP68 ( L051 )• Linear accuracy : ± 0.5 % of F.S• Operating range : 0 ... 50 °C ; 0 ... 100 %RH

Exhaust gas Emission

AFMS-160 AFMT PHM33 PMD33

Recommend

Signal / Meter / Recommend

• Input : Voltage / Current • Output signal : Analog output / RELAY / RS-485• Accuracy : 0.2 % F.S. ± 1 digital(DPT02) ; 0.1 % F.S. ± 1 digital(DPM02)• Power supply / voltage : 85 ... 253VAC, 50 ... 60Hz• Electric protection : polarity protection & over-voltage

• Output : Operating pressure : Max 10 bar Operating temperature : Max. 250 °C ; Temperature tolerance : 800°C• Installation connection : 12" below 3/4" PT movable thread 18" or more is 1" PT movable thread• Length : 25 ... 1500mm / Customization• Matches eYc P063/SD06+DPM02 or PHM33/PMD33+DPM02

• Range : ±50 ... ±2500pa(PMD33) / 0 ... 500pa(PHM33)• Output : 0 ... 20mA/4 ... 20mA ; 0 ... 1V/0 ... 5V/1 ... 5V/2 ... 10V /0 ... 10V• Linear accuracy(at 25°C) : ±2.0% of F.S.(PMD33) / ±0.5% of F.S.(PHM33) / Signal connection : 3-wire• Load resistance : current output : 4 ... 20mA< 500Ω / 0 ... 10V ≧ 10KΩ• Power supply : 8 ... 35VDC / 12 ... 30VAC / IP65

• Medium : Air• Average flow measuring tube length : 4 ... 40”• Operating pressure : max. 10 bar• Operating temperature : 250 ℃• Stainless steel 316• Application : Exhaust gas Emission

• 330° turnable ; the direction of panel is changeable; good monitoring• Input : 4 ... 20 mA• Input : eg : pressure / differential pressure / Temp. / flow / PH value / load cell, etc• Accuracy : 0.2 % of F.S.• Electrical connection : DIN 43650 plug / M12 connector• Application : Steel Industry / Water Plants Environmental Engineering

• Monitor PM2.5, CO2, temperature & humidity via RS-485 at the same time.• Display Type : High Brightness LED• Signal Output : RS-485 ; Protocol ; Interface : Modbus RTU ; Power : AC 230V / DC 24V, 5A• Display Range with eYc TGP03• Temperature : 0 ... 50 ℃• Humidity : 0 … 100 %RH• PM2.5 : 0 … 500 μg/m3

• CO2 : 0 … 2000 PPM

Provide additional option(ILAC/TAF) test report.

Page 8: Temperature | Humidity | Dew Point | | Pressure | Flow ...€¦ · 04/10/2019  · 2019-eYc-Measuring-specialist-Brochure_20191001 Created Date: 10/4/2019 2:31:46 PM