10
I Page 1 of 10 I MS No: RDSOl2009/ELlMS/0386 (Rev. '1;) ., Issued in 29 Oct, 2012' .."' Telephone : 91 - 0522 - 2465754 Fax: 2465754 e-mail: [email protected] , .. . .. I mmm<m-m~ ~ 3If&rcm;q 3fR: d1lO!CI5 ~ ~ -226011 Government of India - Ministry of Railways Research, Designs & Standards Organization, LUCKNOW - 226011 No, EL/4.2.15 Dated 29.10,2012 Chief Electrical Engineer, 1. Central Railway, Mumbai CST-400 001. 2. Northern Railway, Baroda House, New Delhi-110 001. 3. North Central Railway, Allahabad- 211001. 4. Eastern Railway, Fairlie Place, Kolkata ~700 001. 5. East Central Railway, Hazipur-844101. 6. East Coast Railway, Chandrashekharpur, Bhubaneshwar-751 016. 7. Southern Railway, Park Town, Chennai-600 003. 8. South Central Railway, Secunderabad-500 371. 9. South Eastern Railway, Garden Reach, Kolkata -700 043. 10. South East Central Railway, Bilaspur-495004 11. Western Railway, Church gate, Mumbai-400 020. 12. West Central Railway, Jabalpur-482 001. 13. Chittaranjan locomotive works, Chittaranjan, West Bengal 713 331 MODIFICATION SHEET NO. RDSO/2009/ELlMS/0386 Rev '1' Dated: 29.10.2012 [This supersedes RDSO modification sheet no. RDSO/200S/ELlMS/0386 Rev '0' dated 12.08.2010.] 1. Title: Modification in loco control circuit for multiple unit operation (MU) max. for three locos for 25 kv ac electric locomotive working with microprocessor based control and fault diagnostic system (MPCS) as per RDSO's specification. No. ELRS/SPEC/MPC-FDS/0001 Rev-'2'- August 2005 (ver-2) 2. History: The modification sheet no. MS 386 was issued in the month of Aug 2010 to standardize the scheme for multi loco operation. The scheme was not working for consist (three loco) operation 'and as such the same is being revised as Rev '1' along with other improvements. 3. Object: The MU operation (max. for three locos) of conventional 25 kv AC electric tap changer locomotive with MPCS is to be standardized for reliable and effective operation of locomotive. .

Telephone - rdso.indianrailways.gov.in

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Telephone - rdso.indianrailways.gov.in

I Page 1 of 10 I MS No: RDSOl2009/ELlMS/0386 (Rev. '1;) ., Issued in 29 Oct, 2012' .."'

Telephone : 91 - 0522 - 2465754Fax: 2465754e-mail: [email protected]

, .. . .. Immm<m-m~

~ 3If&rcm;q 3fR: d1lO!CI5 ~

~ -226011Government of India - Ministry of Railways

Research, Designs & Standards Organization,LUCKNOW - 226011

No, EL/4.2.15 Dated 29.10,2012

Chief Electrical Engineer,

1. Central Railway, Mumbai CST-400 001.2. Northern Railway, Baroda House, New Delhi-110 001.3. North Central Railway, Allahabad- 211001.4. Eastern Railway, Fairlie Place, Kolkata ~700 001.5. East Central Railway, Hazipur-844101.6. East Coast Railway, Chandrashekharpur, Bhubaneshwar-751 016.7. Southern Railway, Park Town, Chennai-600 003.8. South Central Railway, Secunderabad-500 371.9. South Eastern Railway, Garden Reach, Kolkata -700 043.10. South East Central Railway, Bilaspur-49500411. Western Railway, Church gate, Mumbai-400 020.12. West Central Railway, Jabalpur-482 001.13. Chittaranjan locomotive works, Chittaranjan, West Bengal 713 331

MODIFICATION SHEET NO. RDSO/2009/ELlMS/0386 Rev '1'Dated: 29.10.2012

[This supersedes RDSO modification sheet no. RDSO/200S/ELlMS/0386 Rev '0'dated 12.08.2010.]

1. Title:Modification in loco control circuit for multiple unit operation (MU) max. for threelocos for 25 kv ac electric locomotive working with microprocessor based controland fault diagnostic system (MPCS) as per RDSO's specification. No.ELRS/SPEC/MPC-FDS/0001 Rev-'2'- August 2005 (ver-2)

2. History:The modification sheet no. MS 386 was issued in the month of Aug 2010 tostandardize the scheme for multi loco operation. The scheme was not working forconsist (three loco) operation 'and as such the same is being revised as Rev '1'along with other improvements.

3. Object:The MU operation (max. for three locos) of conventional 25 kv AC electric tapchanger locomotive with MPCS is to be standardized for reliable and effectiveoperation of locomotive. .

Page 2: Telephone - rdso.indianrailways.gov.in

I p~ge 2 of ~~ .1M.s No..RD~O/26~9iELlrv1S/03~6 (Rev. '1').

4. Modified Arrangement:

4.1 Arrangement for sharing of signals and their related circuit diagrams aregiven in annexure- A, 8, C & D.

I Issued in 29 Oct, ?Ol~1

4.1.1 4 input ( 1-84, 1-92, 1-69 & 1-74) and 3 output ( 0-40, 0-41 & 0-36) are shared.between leading and trailing locos as per block diagram shown in Annexure- A &B. As per required modifications, these input/outputs should be connected to theMU coupler pins as shown in Annexure - A & B as per the details given below-

a) Output of 0-41 for 049 (Wire no.237) should be connected through a VS -GR SYN to input no. 1-92 (wire no. 262) of the same loco. Wire no. 262·should be connected to MU jumper no. 014 as per Annexure - A.

b) Output of 0-40 for 051 (Wire no.259) should be connected through a VS -AU REG to input no. 1-84 (wire no. 261) of the same loco. Wire no. 261should be connected to MU jumper no. 015 as per Annexure - A.

c) As per modification sheet no. ROSO/2008/ELlMS/0384 Rev '0', N/Ointerlock of Bl and BlOJ were used in MTOJ branch. If the status of BlOJkey is taken into this circuit of rear locomotive, it will not allow closing of theOJ while operating from leading loco. Hence, wire no. 053 and 053/1 are tobe shorted with a jumper in rear locomotive only for MU operation. Whenthis rear loco is departed from MU operation then wire no. 053 and 053/1jumper should be removed again for single loco operation.

d) While· forming locomotives in MU operation, it should be checked thatBPEMS switch is provided, which is being provided by ClWin newlocomotives since 2007. This will ensure added safety in case ofbreakdown of MPCS completely.

e) Those locomotives which are not having BPEMS switch, the same shouldbe provided in shed during AOHIIOH or at any other suitable opportunity atthe earliest as an added safety features.

f) One new input 1-93 (Bl_MU) of Bl switch spare inter lock should be addedfor recognizing leading loco or trailing loco in multiple unit operation.Connection of Bl switch spare interlock should be taken from both thecabs and after ORing should be fed to 1-93.

4.2 Removalof MU jumpers from locomotive circuit as given in Annexure-C

4.2.1 The following wires going to MU coupler should be removed from all locomotives(for both multi unit and single unit operation) fitted with MPCS as per the modifiedcircuit given in the loco circuit sheet 10 of ClW ORG. No. 15000.004.

a) Since relays Q49 and Q52 are eliminated in MPCS, the ASMGR BN (1-16)and ASMGR ON (1-24) are not required in case of MU operation. So thereis no need of extension of these signals to MU coupler.

b) MU jumper no. B-7 from wire no. 072 of ASMGR (BN) used for 1-16.

c) MU jumper no. B-10 from wire no. 082 of ASMGR (ON) used for 1-24.

d) MU jumper no. B-8 from wire no. 073 of BlCP used through RGCP for1-17. This wire is required to be removed to take care of the auto cut OFFof compressors of rear locomotives from leading locomotive.

Page 3: Telephone - rdso.indianrailways.gov.in

I Page 3 of 10 ,I.MS No. RDSO/2009lELlMS/0386 (Rev. '1') . "I Issueci iI129 Oct, 2012' 'I

4.2.2. MU couplers are to be covered properly with spring loaded covers to protect fromrain water and external foreign particles. A proper sealing arrangement should bedone with RTB silicon compound as a precautionary measure. There are chancesthat the noise signal may generated due to moisture/water. This becomes morerelevant with microprocessor based system as they are more susceptible to noisesignal even at a very low level.

4.3 Addition of new MU jumper in locomotives circuit as given in Annexure-B &Annexure - C

a) A new MU jumper no. C13 will be used for VESAs coil of sanding circuit asshow in annexure-D. Two diodes (VS 20) are to be used to protect MPCSoutput 0-23 and 0-25.

b) Two MU jumper no. B-7 & B-10 and one input 1-74 through a diode VSLSGRP will be used for LSOL signaling lamp for fault indication in trailingloco in MU operation. LSOL lamp output will be fed according to the softwarelogic as shown in annexure- B.

c) Output of 0-36 for LSGRP _S (Wire no. 235) should be connected throughdiode VS -LSGRP to input no. 1-74 (wire no. 260) of the same loco. Wire no.260 should be connected to MU jumper no. B-7. One Input 1-69 (wire no.263) will be connected to MU jumper no. 8-10 in cross connection with B-7as per annexure B.

5.0 Multiple unit/consist loco circuit description for notching & fault indicationas per new scheme

5.1 Considerations:

5.1.1 Condition for recognition of leading loco as below:

• Input BL_MU (1-93) = 1 for leading loco.

• Input BL_MU (1-93) = 0 for trailing loco

5.1.2 There are two pilot lamps for indication of fault in trailing loco in MUoperations. These are LSGRP for Recapitulation [fault] lamp (RED) andLSOL for Trailing loco fault indication Lamp (Yellow).

a) All the logic consideration should be made according to leadinglocomotive.

b) Normal condition of the loco both the lamps LSOL & LSGRP are in'OFF' condition.

i. LSOL = 0ii. LSGRP = 0

c) Lamp condition in Healthy loco if fault exists in any loco.i. LSOL = 1ii. LSGRP = 0

d) Lamp condition in Faulty loco.i. LSOL = 0ii. LSGRP = 1

Page 4: Telephone - rdso.indianrailways.gov.in

I Page 4 of 10 . IMS No. RDSO/2009/EL/MS/0386 (Rev. '1;) .1 Issued. in 29 Oct, 2012

e) Condition for LSGRP lamp glowing:-i. OJ trip condition (QV60=1).ii. CHBA on faulty condition (QV61 =0).iii. Q50 becomes de-energise & QV64=1.iv. RSI block fuse blown (QV63=1).

5.2 Input/output & their MUjumper used:

The following 1I0's & jumpers are used for Multiple unit! consist loco circuit.

Inputs:

1. 1-692. 1-74

3. 1-844. 1-92

Outputs:

1. 0-362. 0-37

3. 0-40

4. 0-41

=(LSGRP) from trailing loco= Trailing loco fault signal.

= 051 relay for auto regression of trailing loco.

= 049 relay for notch synchronization from trailingloco.

= LSGRP of leading loco.= LSOL of Leading loco.

= 051 relay for auto regression of leading loco.

= 049 relay for notch synchronization of leading loco.

[jumper 8-10][jumper 8-7][jurnper 0-15]

[jumper 0-14]

[jumper 8-7][no jumper]

[jumper 0-15]

[jumper 0-14]

5.3 Auto regression logic for Multiple unitl consist loco circuit.

i. Occurrence of auto regression in leading loco:-

Condition in leading loco: 0-40 = 1 , 1-84 =1 & 0-15 = 1Condition in others trailing locos: 0-40 = 0, 1-84 =1 & 0-15 = 1(Auto regression works in other loco through 0-15 MU jumper.)

ii. Occurrence of auto regression in trailing loco:-

Condition in leading loco: 0-40 = 0, 1-84 =1 & 0-15 = 1Condition in anyone of others locos in which auto reg. occur:

0-40 = 1, 1-84=1 & 0-15 = 1(Auto regression works in other loco through 0-15 MU jumper.)

5.4 Notch synchronization for Multiple unitl consist loco circuit.

i. Logic for Q49 in leading loco:-

Condition in leading loco: 0-41 = 1 ,1-92 =1 & 0-14 = 1Condition in others trailing locos: 0-41 = 0, 1-92=1 & 0-14 = 1(Q49 logic works in other loco through 0-14 U jumper.)

Page 5: Telephone - rdso.indianrailways.gov.in

IPage 5 of 10 . IMS No.RDSO/2009/ELlMS/0386 (Rev.· '1?· J Issued in 29 Oct? 2012 ..

ii. Notch syncronisation in trailing loco:-

Condition in leading loco: 0-41 = 0, 1-92 =1 & 0-14 = 1Condition in anyone of others locos in which 049 acted:

0-41 = 1, 1-92=1 & 0-14 = 1(Auto regression works in other loco through 0-14 MU jumper.)

5.5 LSOL fault indicator logic for Multiple unit! consist loco circuit.

(a) Positions of I/O status & its meaning in Leading loco

SN Description 1-74 1-69 0-36 0-371. Leading loco fault 1 0 1 0

2. T. loco-1 fault 0 1 0 1

3. T. loco-2 fault 1 0 0 1

4. All loco healthy 0 0 0 0

(b) Positions of 110status & its meaning for MU/C locomotives.

Leading loco T. Loco-1 T. Loco-2SN Description

0-361-74 1-69 0-37 1-74 1-69 0-36 0-37 1-74 1-69 0-36 0-37

1. Leading loco 1 0 1 0 0 1 0 . 1 1 0 0 1fault

2. T. loco-1 fault 0 1 0 1 1 0 1 0 0 1 0 1

3. T. loco-2 fault 1 0 0 1 0 1 0 1 1 0 1 0

4.All loco 0 0 0 0 0 0 0 0 0 0 0 0healthy

5.6 If HAPR bypass switch is normal (1-70=0) in the leading loco, all the locomotivesin MU operation should take HAPR as normal. If HAPR bypass switch isbypassed (1-70=1) in the leading loco, all the locomotives in MU operation shouldtake HAPR as bypassed. The HAPR bypass is only for 00 and ACP circuit. Theother conditions of auto regression will still initiate auto regression.

6.0 Work to be carried out:Modified circuit explained as above. Software should also be implemented by themanufacturer as perMS 0386 Rev '1' at the time of implementation.

7.0 Application to class of locomotive:WAG-7, WAGS, and WAM-4 class of 25 Kv AC conventional tap changer electriclocomotives with microprocessor based control and fault diagnostic system(MPCS).

The locomotives already modified as per ROSO modification sheet no. 0386 Rev'0' are to be converted to ROSa modification sheet no. 0386 Rev '1'. Locomotivecircuit following MS 0386 Rev '0' cannot be formed in multi with MS 0386 Rev '1'.

Page 6: Telephone - rdso.indianrailways.gov.in

I Page 6 or'10· r MS No. RDSO/2009/ELlMS/0386 (Rev. T) , I Issued in 29 Oct, 20~2

8.0 Material Required:1. Five Blocking diodes 12 amp.2. Control cable of 2.5/3 mm2 as per requirement.

9.0 Material Rendered Surplus: NIL

10.0 Modification Drawings:Modified circuit given in Annexure-A to Annexure-D

11.0 Agency of Implementation:Electric loco sheds, MTR/POH workshops and CLW

Encl: As above

!kt:(S. K. Gupta)

for Director General/Elect.

Page 7: Telephone - rdso.indianrailways.gov.in

0-150-15

MPCS· ~40510-40

259VSAUREG

.,,- '- 261

0

MPCS ~4·0510-40

~,259

VSAUREG - f-- 2615 0-

0-15

MPCS J=840510-40

259VSAUREG ~

,- f-- 261

5

0-15

Auto-regression circuit for ConsisUMU loco operation

0-140-14

MPCS r-Hl2Q490-41

237VS GRSYN ~ ~ 262--' 0-1

MPCS r-Hl2

0490-41

237VS GRSYN ~

,262--' f--

4

MPCSQ490-41

r11l2

0-1~b0-14

Synchronization circuit for ConsisUMU loco operation

237VS GRSYN ~,-r 2

_6_2_--,4

0-14

Annexure- A"'0

P>(1Q(\)

'I.0.....,•..•0

s:(f)

z9:::00(f)

00-15 ~

00-15 0

co---mr----s:(f).---cs.co000>-----:::0CD:0::->:---.;

0-140-14

. >-<00

·00c:(\)0-

s·t\.)\0

o. () .r+

Page 8: Telephone - rdso.indianrailways.gov.in

MPCS

LSGRP _0 LSGRP_S

1-69 0-36

263

8-7

235VS LSGRP

1-74

260

MPCS1-74

LSGRP_O LSGRP_S 2601-69 0-36235

263 ,~ VS LSGRP

15-

u- 1'-'8-10 8-10 8-

2638-7 260 8-7 8-18-10

2608-10 263

260

8-7 8-7

8-7

260

263

Annexure- B

LSGRP _0 LSGRP_S

1-69. 0-36

MPCS

260

263

7

o 263

1-74

235VSLSGRP

LSOL fault locator circuit for MU loco operation

8-7 8-7 8-7 8-7

8-7

8-10

0-f-----~

8-7

8-10 260 8-10

Note:- Modification in software for LSOL (0-37) lamp logic to be done by manufacturer as given below

8-7

8-10 263 263

Output 0-37 of LSOL lamp = [(1-69 OR 1-74)AND 0-36]

Legend: LSGRP _0 means LSGRP for other locoLSGRP _S means LSGRP for same loco

260

'"t:lPl

'(]Qro'000. ....,•..•o·

$:-en2:9:::0CJenQ

.N0

·08-7 !:2

m-r----se8-10 ·m<;

·0wClO(J)

-------::0CD-:<->:<:

tv·a~.tv

Page 9: Telephone - rdso.indianrailways.gov.in

I Page 90f 10 . I.MSNO.RDsoli2009IEL/MSI0386 (Rev. '1')· . ) Issued in 29 O~t, 2012

ASMGR8ETWEENNOTCH

8-78-7

700

I,.

ASMGR8ETWEENNOTCH

Annexure- C

ASMGR oJI INOTCHi .

o,o::Jen

073

8-7 8-8 8-88-7 8-8 13-8

8-10 8-108-10 8-10 E-D RGCP072 082

074

1-16 1-24 1-17

MICROPROCESSOR UNIT

Existing Circuit

700

072

ASMGR oJ11NOTCHr

1-16

073

082 E-D RGCP

" 074

1-24 1-17

MICROPROCESSOR UNIT

Modified Circuit

Page 10: Telephone - rdso.indianrailways.gov.in

I Page ·10 of 10 I MS No. RDSOl20091EUMS/0386 (Rev. '1) . IIssuedin 29 Oct, 2012

Annexure- 0

MICROPROCESSOR UNIT

0-23 0-25

MICROPROCESSOR UNIT

0-23 0-25

VESA1

C-13C-13

C-13C-13

J1J2 For J1J2 Rev

VESA2 VESA2VESA1

Modified CircuitExisting circuit

(Sender working with MU operation)