24
Keku ® Fitting and room system Technical values

Technical values - KeKu · 2018-12-18 · Plates, solid plastic plates, acrylic plates, gypsum fiber boards, cement fiber plates, etc. For all plates, the processing instructions

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Keku® Fitting and room system

Technical values

Keku® Fitting and room system

Contents

Section Page

Technical values ------------------ 2

------------------ 3

------------------ 4

------------------ 5

------------------ 6

------------------ 7

------------------ 8

------------------ 9

------------------ 10

------------------

Data sheet ------------------ 11

------------------ 12

------------------ 13

------------------ 14

Theme

Description

Suspension fittings

Push-in fittings

Double-partition fittings

Material properties

Metal fittings

Metal fitting properties

Keku® room system

Keku® room system

"Abgehängte Decke"

Suspended CeilingWall cladding

Stud wall cladding

Shockproof stud wall cladding ------------------ 15

Wall cladding without floor connection ------------------ 16

Stud wall cladding without floor

connection

------------------ 17

------------------

Keku® Fitting system Quality assurance ------------------ 18

Summary ------------------ 19

Load table for ceiling suspension ------------------ 20

Keku® room system Load table for ceiling suspension ------------------ 21

------------------

References Photo ------------------ 22

zurück

Keku® FittingEH and EHS suspension fitting,AS and ASR slide-on fitting,AD 15 and AD 30 double partition fitting

The fire class of the components depends on the materials of the processed panelling and cladding

materials. The Keku® R aluminium room system is regarded as not flammable. Fire class A

According to a uniform statement from the material testing institutes, fittings must generally only be assessed with regard to fire resistance in accordance with DIN 4102 in the installed condition and in connection with a component.

This means that the Keku® fittings are also not tested as individual components in the noninstalled condition and are not regarded as materials such as the subconstruction or the panelling and finishing material, which is evaluated in accordance with fire protection class A1, A2 (not flammable) or B1 (hardly inflammable), B2(normally inflammable) or B3 (easily flammable).

Please note the processing instructions and technical values. We will gladly provide load tables and data sheets for you.

The processing of the Keku® system requires conscientious, skilful handling. Trial assemblies are recommended for special loads and unusual designs. Persons unfamiliar with the trade and maintenance personnel must be provided with instruction about the handling of the inspection panels.

Technical values

Keku® suspension fittings EH and EHS

Panel component Keku® EH - Art.-Nr.: 262.49.356 und 262.49.357,

Frame component Keku® EH - Art.-Nr.: 262.49.360, 262.49.365 und 262.49.366,

Frame component Keku® EHS - Art.-Nr.: 262.49.367 und 262.49.368

Keku fittings are made of polycarbonate (PC).

The production of the fittings is subjected to continuous quality control.

The Keku fittings resist short-term tensions and compression forces of 300N and then have to return

to the starting position.

The maximum load capacity of a pair of fittings in the following applications is:

• For vertical suspension in e.g. wall panels 20 kg

• For horizontal application, lying e.g. pedestal panels 30 kg

• For horizontal applications, hanging e.g. ceiling panels 8 kg

At least 4 pairs of fittings are required when hanging a rectangular panel. The spacing depends on the panel thickness as well as the arrangement of attachment points and should not exceed 600 mm. For uniform distribution of the load, the fittings must be positioned precisely.

Regarding the number of different applications, we recommend that the worker performs a trial assembly.

Load carrying plastic fittings should not be treated with chemical solutions or aggressive greases.

The processing parameters contained in the Häfele catalogue must be observed.

zurück

Technical values

Keku® Push-in Fittings AS und ASR

Panel component Keku® AS - Häfele Art.-No.: 262.50.359 and 262.50.358,

Frame component Keku® AS - Häfele Art.-No.: 262.50.368 and 262.50.377,

Frame component Keku® ASR - Häfele Art.-No.: 262.50.390 and 262.50.39

Keku fittings are made of polycarbonate (PC).

The production of the fittings is subjected to continuous quality control.

The Keku fittings resist short-term tensions and compression forces of 300N and then have to return

to the starting position.

The maximum load capacity of a pair of fittings in the following applications is 20 kg.

These values are not valid for the coupling effect of push-in fittings AS and ASR.

These push-in fittings are not for hanging loads e.g. ceiling tiles.

At least 4 pairs of fittings are required when hanging a rectangular panel. The spacing depends on the panel thickness as well as the arrangement of attachment points and should not exceed 600 mm. For uniform distribution of the load, the fittings must be positioned precisely.

Factory specifications for the number of AS fittings Center distance at 19 mm plate thickness max. 1000 mm

Panel weight Number of As- fittings

to 20 Kg 4

to 30 Kg 6

to 40 Kg 8 to 50 Kg 10

Regarding the number of different applications, we recommend that the worker performs a trial assembly.

Load carrying plastic fittings should not be treated with chemical solutions or aggressive greases.

The processing parameters contained in the Häfele catalogue must be observed.

zurück

Technical values

Keku® Double Partition Fasteners AD15 and AD 30

Panel component Keku® EH - Art.-No.: 262.49.356 and 262.49.357,

Angle component Keku® AD 15 - Art.-No.: 262.51.380 and 262.51.381,

Angle component Keku® AD 30 - Art.-No.: 262.51.390 und 262.51.391

Keku fittings are made of polycarbonate (PC).

The production of the fittings is subjected to continuous quality control.

The Keku fittings resist short-term tensions and compression forces of 300N and then have to return to the

starting position.

The maximum load capacity of a pair of fittings in the following applications is 20 kg. At least 4 pairs of fittings are required when doubling up and connecting panels. When coupling elements the distance between fittings should be approx. 600 mm.

For uniform distribution of the load, the fittings must be positioned precisely.

Regarding the number of different applications, we recommend that the worker performs a trial assembly.

Load carrying plastic fittings should not be treated with chemical solutions or aggressive greases.

The processing parameters contained in the Häfele catalogue must be observed.

Technical values

zurück

Material properties:

Keku® R room system and Keku® hardware system

The Keku fittings are sold since 1982 by the company Häfele GmbH & Co.KG in millions.

Polycarbonate combines many good properties of metals, glass and plastics such as stiffness, impact resistance, dimensional stability, good insulating properties and good heat resistance.

It is considered as a high-quality engineering plastic with high strength and hardness with good toughness. Its good electrical insulating properties are almost independent of ambient temperature and humidity. The high dimensional stability in heat and the low thermal expansion coefficient show good thermal behavior.

Polycarbonate is flame retardant but burns bright, sooty and self-extinguishing. The polycarbonate (PC) we use is the ideal material for the functions of the Keku-R hardware system.

Information required by the Material Examination Offices Berlin and DortmundThe metallic parts of the substructure can comply with DIN 4102-4 of building material class Al(non-combustible).The fittings made of polycarbonate require no proof of fire behavior if the following boundary conditions are met:Mass less than or equal to 50g and dimensions less than or equal to 50mm x 50mm.The contribution to the incipient fire and transmission can then be neglected. Separate evidence of the fire behavior must be provided for the board materials used.Either by general building authority test certificates (ABP) or by general building inspectorate approvals (ABZ) or by CE marking.Due to the purpose of use there are currently for the metalComponents of the room system no requirement of a building inspection approval.

zurück

Technical values

zurück

Suspension fitting Keku® EH-metal

Häfele Art.-No.: 782.15. Häfele Art.-No.: 782.15. Häfele Art.-No.: 782.15.

Panel component Keku® EH-M Frame component Keku® EH Frame component Keku®EHS

Keku® EHM- Panel componentKeku® EH- Frame component Keku® EHS- Frame component

Stamped and bent part Turned partTurned part

Stainless steel 1.4310 Steel, galvanizedSteel, galvanized

The coupling effect depends on many different parameters. Plate material, plate thickness, tightening forces of the fittings, accuracy of the Keku positions, etc.

Self-tests are indispensable for determining the locking effect.

At least four fittings are required when hanging a rectangular panel. The spacing depends on the panel thickness as well as the arrangement of attachment points and should not exceed 600 mm. For uniform distribution of the load, the fittings must be positioned precisely.

Given the multitude of possible applications, we recommend to the fabricator, for special requirements, make trial fittings.

The production of fittings is subject to constant quality control.Various special screws are available for attaching the fittings to the Keku®R system.

The maximum load capacity of a pair of fittings in the following applications is:

• For vertical suspension in e.g. wall panels 20 Kg• For horizontal application, lying e.g. pedestal panels 30 Kg• For horizontal applications, hanging e.g. ceiling panels 8 Kg

Technical values

KEKU®M Safety fitting of metal for KEKU® R room system

Panel component Keku-M Frame component Keku EH-M Frame component Keku EHS-M

Material Stainless steel1.4310 Steel galvanized Steel, galvanizedWeight 0,013 kg 0,008 kg 0,010 kg

Dimension 78,5 x 16 x 12 mm 4,2 x 20 mm 4,2 x 24 mm

Fixing Panhead 4 x 16/20 mm DG-Lens head screwfor Alloy 4 x 25 mm

(for Alu profiles)DG-countersunk head screw f. Alloy 4 x 30

mm (for Alu profiles)Load values* 8 kg per fitting /At least 4 fittings per plate 12 kg per Bolt on the supporting profile 12 kg Bolt on the supporting profileCoupling effect ca. 6 kg per Fitting (The lcoupling effect increases by the number of fittings.)

Suspension stroke 12 mm

Extract values* >20 kg bei 4 x 16mm Panhead-screw in 19 mm MB-plate

>20 Kg lateral shear forcei on the Alu- profile

>20 Kg lateral shear forcei on the Alu- profile

Comment Mounting holes as in the Keku System

Properties Building Material class A1, non-flammable

Applocation

Building material class A1, non-flammable, not rustingFor the production of non-combustible components With cornering

* The pull-out values apply to high quality panels and the Keku room system. Possibly. Make screw tests.

7,5

33

Building material class A1, non-flammable

zurück

Keku®R room system

The Keku® R-System is a universal aluminum substructure for the production of individual wall and ceiling coverings as well as partitions in interior fittings.The system consists of the following profiles a 6 meters:782.10.006 Supporting profiles H-profile 36 x 36 mm with rows of holes in grid 32 and slotted holes in the grid

64 mm. With construction grooves for holding various chipboard fittings and joint profilesH-profile 36 x 26 mm with construction and notches.782.11.006 Floor-/ceiling profile

Profiles 3 Meter:

782.12.003 Adjusting profile

782.13.003 Joint profile34 x 6 mm for accommodation of floor profile.

33 x 5 mm Clip in after basic instalation.

• Suspended ceilings• Wall cladding• Stud wall cladding• Wall cladding without floor connection• Stud wall cladding without floor connection• Shockproof stud wall cladding

As panels all screwable plates of 10 to 30 mm thickness are suitable. Blockboard, chipboard, MDFPlates, solid plastic plates, acrylic plates, gypsum fiber boards, cement fiber plates, etc. For all plates, the processing instructions of the respective manufacturers apply.The data sheets represent common applications for wall and ceiling coverings in interior design.The load values refer to 19 mm cladding panels with decorative surfaces.Special constructions, special plates, or special high loads require own trials of the processor and possibly reinforced constructions. The system is not suitable for the production of seamless GK walls and ceilings.

zurück

782.14.003 Joint profile, with slots 33 x 5 mm Slots 6 x 25 mm, at 50 mm intervals (shopfitting standard) 782.14.010 Joint profile, horizontal 57 x 6 mm For horizontal joints up to 30 mm. For fixing with EH/AS

panel componets.

The system also includes numerous accessories for connecting, adjusting and fixing the profiles.The material of the profiles is aluminum T66, the accessories are made of aluminum and steel.The system includes all the accessories needed for a substructure.The Keku fittings EH / EHS and ASR are specially adapted to the Keku® R system and allow a reversible attachment of the cladding panels.The profiles are processed using standard joinery machines.

The following datasheets with proven factory specifications are available for planning.

Technical values

zurück

Keku®R room system

b<= 83 mm

)ugbelastung vertikal: Verschraubung:

Bei Deckenverkleidung 8 Kg pro Beschlagpaar DG‐Schraube 4 10 mm 78 .17.900Systemschraube zwingend erforderlich für dieVerschraubung der Keku‐Beschläge am Tragprofil

<= 1408

belie

big

Achsabstand der Profile <=1000 mm

<= 1000 mm

Breite der DECKENPLATTE ist abhängig von:Platteneigenschaften DurchbiegungSchraubfestigkeit des PlattenmaterialsHinweise des Plattenherstellers beachten

Bei Bedarf Mittelprofil einsetzen.

Keku Beschlägenicht mit chemischen Lösungen und aggressiven Fetten behandelnnicht durch Schlagen justierenMindestens 4 Keku Beschläge pro Platte einsetzenDübel und Befestigungsmittelnach den jeweiligen Anforderungen auswählenHinweise der Plattenhersteller beachtenTabelle für Zugbelastung beachtenevtl. Schraubversuche

Schn

itt A

Schnitt B

Schnitt A

Schnitt B262.49.367 EHS Rahmenteil Hospa262.49.357 EH Plattenteil Varianta

Deckenbefestigung

782.10.006 Tragprofil

a ca. 100mm

aca. 100mm

Standardwerte nach Werksangabe

Deckenplatte Material:Gewicht: Abmessung:

Befestigung Beschlagtyp: Material:Lastwerte: Verschraubung: Auszugswerte:

Unterkonstruktion Material: Abmessung:

Deckenbefestigung:

Beschlagtyp: Material:

MB‐Platte 19mm13,3Kg 700kg/cbm1000 1000 19 mm

Keku EH Plattenteil Varianta Einhängebeschlag mit Rastnase 6 .49.357 Polycarbonat PCBei Deckenverkleidung 8 Kg pro BeschlagspaarVariantaschraube 6, 13,5 mm / Spa 4 0 mmVarianta/Spa > 0 Kg MB‐Platte 19 mm

Keku RAluminium T66H‐Profil 6 Meter 36 36 mmGewindestange M8 mm mit zugelassenen, geeigneten Kompaktdübeln. Nicht im LieferumfangVerschraubung am Tragprofil mit Muttern M8 und U‐Scheiben. )ulässige Last der Verschraubung am Tragprofil beträgt 50 Kg. Gewindestangen und Muttern nicht im Lieferumfang

Keku EHS Rahmenteil Hospa Einhängebeschlag mit Seitenführung 6 .49.367 Polycarbonat PC

Abgehängte DeckeDatenblatt

zurück

b<= 83 mm

<= 1408

belie

big

Spacing of the profiles <=1000 mm

<= 1000 mm

The width of the ceiling panel depends on:Panel characteristics sagScrew fi ing strength of panel materialpay attention to the panel manufacturer’s information

Use centre profile if necessary

Do not treat Keku fittings with chemical solutions and aggressive greasesDo not adjust by hammeringUse at least 4 Keku fittings per panelSelect dowels and fixing materials in accordance with the respectiverequirementsPay attention to the panel manufacturer’s informationPay attention to tensile load tableCarry out screw fixing tests if necessary

Section B

Section A

Section B

262.49.367 EHS Frame component Hospa262.49.357 EH Panel component Varianta

Ceiling mounting

782.10.006 Supporting profile

a ca. 100mm

aca. 100mm

Sect

ion

A

Su ‐ onstru tion Keku RMaterial: Aluminium T 66Dimensions: H‐profile 6 metres 36 36 mmCeiling installation: Threaded bolt M8 with approved, suitable compact dowels not included in scope of

deliveryScrew fi ing to support profile with M8 nuts and U‐washers. The permissible load of the screwfi ing to the support profile is 50kg. Threaded bolts and nuts not included in scope of delivery

Fitting type: Keku EHS frame component Hospa suspension fitting with lateral guide 6 .49.367Material: Polycarbonate PCTensile load, vertical: 6 kg per fitting with ceiling panellingScrew fitting: DG screw 4 10 mm 78 .17.900 System screws are mandatory for screw fi ing the Keku

fittings to the support profile.

Default values according to factory specification

Ceiling tileMaterial: MB plate 19mmWeight: 13.3Kg 700kg / cbmDimension: 1000 1000 19 mm

attachmentFitting type: Keku EH plate part Varianta hanging fitting with latch 6 .49.357Material: Polycarbonate PCLoad values: For ceiling cladding 6 kg per fitting pairScrew connection: Variant screw 6. 13.5 mm / Spa 4 0 mmE tract values: Varianta / Spa > 0 Kg MB plate 19 mm

Suspended Ceiling Data sheet

zurück

Panel  aterialMaterial:Weight:Dimension:

Fitting type:

Material: Load values: Screw connection:Extract values:

MB-plate 19mm26,6 Kg (700kg/cbm)2000 x 1000 x 19 mm

Keku EH plate part Varianta 262.49.351Keku EH plate part Hospa 262.49.350 Polycarbonate (PC)20 Kg per fitting pair in Wall cladding Varianta screw 6,2 x 13,5 mm / Spax 4 x 20 mm Varianta/Spax > 20 Kg (MB-plate 19 mm)

Su ‐ onstru tion Keku RMaterial: Aluminium T66Dimension: H‐profile 6 metres 36 36 mm

Wall mounting: 3D wall / ceiling mounting 782.00.900 with approved,suitable compact dowels *

Load values: 40 Kg with wall distance 40-50 mm (adjusting screw)Floor connection: Floor profile with profile connectorSupporting values: 80 Kg profile connector braced in the support profile

Floor profile bolted to the floor as load distribution

Fitting type: Keku EHS frame part Hospa 262.49.367Keku EH frame part Hospa 262.49.365

Material: Polycarbonate (PC)Tensile load, vertical: 20 kg per fitting pair -for wall cladding-Screw connection: DG screw 4 x 10 mm 782.17.000 (for the hole row at

Support profile) System screw mandatory forScrew connection on the support profile

* Dowels and screws are not included in the Keku range

ma

imal

er A

bsta

nd 1

408

ma imum center distance of the profiles 1000 mm

see information of the plate manufacturer

The distance between the TRAGPROFILEdepends on:Plate format and joint divisionboard properties

Width of the plate depends on:Plate properties (deflection)

Schnitt B

Schnitt A

262.49.367 EHS Rahmenteil Hospa262.49.351 EH Plattenteil Varianta

782.00.900 3 D Wand-/Deckenbefestigung

782.10.006 Tragprofil

Sc hn itt A

782.15.060 Profilverbinder782.11.006 Bodenprofil

ca. 7

00 m

m

ca. 1

00m

aim

al 8

64 m

mm

aim

al 8

64 m

mca

.100

Schnitt B

Wandabstand40‐50 mm

For panel widths over 1000 mm or special surface loadswe recommend an additional, centrally arranged support profile.

Default values according to factory specification

Wall claddingData sheet

Do not treat Keku fittings with chemical solutions and aggressive greasesDo not adjust by hammeringUse at least 4 Keku fittings per panelSelect dowels and fixing materials in accordance with the respectiverequirementsPay attention to the panel manufacturer’s informationPay attention to tensile load tableCarry out screw fixing tests if necessary

zurück

Panel  aterialMaterial: MB-plate 19mmWeight: 26,6 Kg (700kg/cbm)Dimension: 2000 x 1000 x 19 mm

Fitting type: Keku EH plate part Varianta 262.49.351Keku EH plate part Hospa 262.49.350

Material: Polycarbonate (PC)Load values: 20 Kg per fitting pairr -wall cladding-Screw connection: Variantascrew 6,2 x 13,5 mm / Spax 4 x 20 mmExtract values: Varianta/Spax > 20 Kg (MB-plate 19 mm)

Su ‐ onstru tion Keku RMaterial: Aluminium T66Dimension: H-profile 6 metres 36 x 36 mm

Wall mounting: 3D Wall spacer 782.00.910 withThreaded bolt M8 and approved,suitable compact dowels (not included in scope of delivery)

Load values: 40 Kg with wall distance 50-300 mm(Threaded bolt M8)Floor connection: Floor profile with profile connectorSupporting values: 80 Kg profile connector braced in the support profile

Floor profile bolted to the floor as load distribution

Fitting type: Keku EHS frame part Hospa 262.49.367Keku EH frame part Hospa 262.49.365

Material: Polycarbonate (PC)Tensile load, vertical: 20 kg per fitting pair -for wall cladding-Screw connection: DG screw 4 x 10 mm 782.17.000 (for the hole row at

Support profile) System screw mandatory forScrew connection on the support profile

* Dowels and screws are not included in the Keku range

ma

imal

er A

bsta

nd 1

408

ma imum center distance of the profiles 1000 mm

see information of the plate manufacturer

The distance between the TRAGPROFILEdepends on:Plate format and joint divisionboard properties

Width of the plate depends on:Plate properties (deflection)

Schnitt A

262.49.367 EHS Rahmenteil Hospa262.49.351 EH Plattenteil Varianta

782.00.910 Wandabstandshalter

782.10.006 Tragprofil

Sc hnit t A

782.15.060 Profilverbinder782.11.006 Bodenprofil

ca. 7

00 m

m

ca. 1

00m

aim

al 8

64 m

mm

aim

al 8

64 m

mca

.100

Schnitt B

Wandabstand50‐300 mm

For panel widths over 1000 mm or special surface loadswe recommend an additional, centrally arranged support profile.

Schnitt B

Default values according to factory specification

Stud wall cladding Data sheet

Do not treat Keku fittings with chemical solutions and aggressive greasesDo not adjust by hammeringUse at least 4 Keku fittings per panelSelect dowels and fixing materials in accordance with the respectiverequirementsPay attention to the panel manufacturer’s informationPay attention to tensile load tableCarry out screw fixing tests if necessary

zurück

Panel  aterialMaterial:Weight:Dimension:

Fitting type:

Material: Load values: Screw connection:Extract values:

MB-plate 19mm26,6 Kg (700kg/cbm)2000 x 1000 x 19 mm

Keku EH plate part Varianta 262.49.351Keku EH plate part Hospa 262.49.350 Polycarbonate (PC)20 Kg per fitting pair in Wall cladding Varianta screw 6,2 x 13,5 mm / Spax 4 x 20 mm Varianta/Spax > 20 Kg (MB-plate 19 mm)

Sub-construction Keku RMaterial: Aluminium T66Dimension: H-profile 6 metres 36 x 36 mm

Wall mounting: 3D Wall spacer 782.00.910 withThreaded bolt M8 and approved,suitable compact dowels (not included in scope of delivery)

Load values: 40 Kg with wall distance 50-300 mm(Threaded bolt M8)Floor connection: Floor profile with profile connectorSupporting values: 80 Kg profile connector braced in the support profile

Floor profile bolted to the floor as load distribution

Fitting Type: Keku EHS frame part Hospa 262.49.367Keku EH frame part Hospa 262.49.365

Material: Polycarbonate (PC)Tensile load, vertical: 20 kg per fitting pair -for wall cladding-Screw connection: DG screw 4 x 10 mm 782.17.000 (for the hole row at

Support profile) System screw mandatory forScrew connection on the support profile

* Dowels and screws are not included in the Keku range

ma

imal

er A

bsta

nd 9

60

ma imum distance of the profilesfor impact resistant walls 700 mm

see information of the plate manufacturer

Center profile for:Shockproof Wall claddingPanel width over 1000 mm

Schnitt A

262.49.367 EHSRahmenteil Hospa262.49.351 EHPlattenteil Varianta

782.00.910Wandabstandshalter

782.10.006 Tragprofil

782.15.060 Profilverbinder782.11.006 Bodenprofil

ca. 1

00m

aim

al 6

40m

mAb

stan

d Ke

ku m

aim

al 6

40 m

mca

.100

Schnitt B

Wandabstand50‐300 mm

Abst

and

Wan

dbef

estig

ung

Ma

. 960

mm

ma

imal

640

mm

Center distance

Schnitt B

Sc hn itt A

Default values according to factory specification

Shockproofstud wall cladding

Data sheet

Do not treat Keku fittings with chemical solutions and aggressive greasesDo not adjust by hammeringUse at least 4 Keku fittings per panelSelect dowels and fixing materials in accordance with the respectiverequirementsPay attention to the panel manufacturer’s informationPay attention to tensile load tableCarry out screw fixing tests if necessary

zurück

Panel  aterial

Material: MB-plate 19mmWeight:Dimension:

Fitting type:

Material: Load values: Screw connection:Extract values:

26,6 Kg (700kg/cbm)2000 x 1000 x 19 mm

Keku EH plate part Varianta 262.49.351Keku EH plate part Hospa 262.49.350 Polycarbonate (PC)20 Kg per fitting pair in Wall cladding Varianta screw 6,2 x 13,5 mm / Spax 4 x 20 mm Varianta/Spax > 20 Kg (MB-plate 19 mm)

Su ‐ onstru tion Keku RMaterial: Aluminium T66Dimension: H‐profile 6 metres 36 36 mm

Wall mounting: 3D wall / ceiling mounting 782.00.900 with approved,suitable compact dowels *

Load values: 40 Kg with wall distance 40-50 mm (adjusting screw)

Fitting type: Keku EHS frame part Hospa 262.49.367Keku EH frame part Hospa 262.49.365

Material: Polycarbonate (PC)Tensile load, vertical: 20 kg per fitting pair -for wall cladding-Screw connection: DG screw 4 x 10 mm 782.17.000 (for the hole row at

Support profile) System screw mandatory forScrew connection on the support profile

* Dowels and screws are not included in the Keku range

ma

imal

er A

bsta

nd 9

60

ma imum center distance of the profiles 1000 mm

see information of the plate manufacturer

The distance between the TRAGPROFILEdepends on:Plate format and joint divisionboard properties

Width of the plate depends on:Plate properties (deflection)

Schnitt B

Schnitt A

262.49.367 EHS Rahmenteil Hospa262.49.351 EH Plattenteil Varianta

782.00.900 3 D Wand-/Deckenbefestigung

782.10.006 Tragprofil

Sc hnit t A

782.15.060 Profilverbinder782.11.006 Bodenprofil

ca. 1

00m

aim

al 8

64 m

mm

aim

al 8

64 m

mca

.100

Schnitt B

Wandabstand40‐50 mm

ma

imal

er A

bsta

nd 9

60

For panel widths over 1000 mm or special surface loadswe recommend an additional, centrally arranged support profile.

Default values according to factory specification

Wall claddingwithout floor connection

Data sheet

Do not treat Keku fittings with chemical solutions and aggressive greasesDo not adjust by hammeringUse at least 4 Keku fittings per panelSelect dowels and fixing materials in accordance with the respectiverequirementsPay attention to the panel manufacturer’s informationPay attention to tensile load tableCarry out screw fixing tests if necessary

zurück

Panel  aterial

Material:Weight:Dimension:

Fitting type:

Material: Load values: Screw connection:Extract values:

MB-plate 19mm26,6 Kg (700kg/cbm)2000 x 1000 x 19 mm

Keku EH plate part Varianta 262.49.351Keku EH plate part Hospa 262.49.350 Polycarbonate (PC)20 Kg per fitting pair in Wall cladding Varianta screw 6,2 x 13,5 mm / Spax 4 x 20 mm Varianta/Spax > 20 Kg (MB-plate 19 mm)

Sub-construction Keku RMaterial: Aluminium T66Support element: 2 support profiles with insertion connector 782.15.110 to one

Support element 109 mm connected. For supporting elementsfrom 108-500 mm depth, connecting struts made of MDF plate 30 mmor multiplex plate 30 mm, screwed through the row of holes.

Wall mounting: 3D wall / ceiling mounting 782.00.900 with approved,suitable compact dowels *

Load values: 40 Kg with wall distance 40-50 mm (adjusting screw)

Fitting type: Keku EHS frame part Hospa 262.49.367Keku EH frame part Hospa 262.49.365

Material: Polycarbonate (PC)Tensile load, vertical: 20 kg per fitting pair -for wall cladding-Screw connection: DG screw 4 x 10 mm 782.17.000 (for the hole row at

Support profile) System screw mandatory forScrew connection on the support profile

* Dowels and screws are not included in the Keku range

ma

imal

er A

bsta

nd 9

60

ma imum center distance of the profiles 1000 mm

see information of the plate manufacturer

Schnitt A

262.49.367 EHS Rahmenteil Hospa262.49.351 EH Plattenteil Varianta

782.00.900 3 D Wand-/Deckenbefestigung

782.10.006 Tragprofil

782.15.060 Profilverbinder782.11.006 Bodenprofil

ca. 1

00m

aim

al 8

64 m

mm

aim

al 8

64 m

mca

.100

Schnitt B

Wandabstand>11 mm

ma

imal

er A

bsta

nd 9

60

Schnitt B

Sc hnit t A

For panel widths over 1000 mm or special surface loadswe recommend an additional, centrally arranged support profile.

Default values according to factory specification

Stud wall cladding without floor connection

Data sheet

Do not treat Keku fittings with chemical solutions and aggressive greasesDo not adjust by hammeringUse at least 4 Keku fittings per panelSelect dowels and fixing materials in accordance with the respectiverequirementsPay attention to the panel manufacturer’s informationPay attention to tensile load tableCarry out screw fixing tests if necessary

The distance between the TRAGPROFILEdepends on:Plate format and joint divisionboard properties

Width of the plate depends on:Plate properties (deflection)

zurück

Quality assurance

The authenticity of our fittings, which are protected by trade mark, can be verified by the following markings:Cacity, material, year of manufacture, month of manufacture and make

1: Cavity2: Material 3: Year4: Month5: Make

A certified quality assurance system monitors all manufacturing processes.

The basic material for the keku fittings is a polycarbonate (PC)

A structural FEM calculation confirms that the assemblies have been made using the materialthat we have specified.

The Keku fittings and the Keku R room system fulfil all requirements of the latest version of theREACH and RoHs legislation.

The legal SCCP limit - short chain chlorinated paraffins - is complied with.

The Keku fittings are made in Germany.

zurück

Kusanke Fon: +49(0) 2351 9508-0Beschlagtechnik GmbH & Co.KG Fax: +49(0) 2351 9508-20Im Wiesental 37 E-Mail: [email protected] Lüdenscheid Web: www.keku.de

Type Keku® Suspension fittings Unhook stroke Inspection of fittings

Type Hospa Varianta Material Standard-Type Temperatur range up Wall panel Floor panel Ceiling panel tension and compression

Frame component EHS 262.49.367 262.49.368 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 Kg 30 Kg 8 Kg 300 N

Frame component EH 262.49.365 262.49.366 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 Kg 30 Kg 8 Kg 300 N

Frame component groove 262.49.360 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 Kg 30 Kg 8 Kg 300 N

Panel component 262.49.356 262.49.357 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 Kg 30 Kg 8 Kg 300 N

Panel component w. lip 262.49.350 262.49.351 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 Kg 30 Kg not suitable 300 N

Area component EH 262.49.358 262.49.359 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 15 kg not suitable not suitable 300 N

Area component EHS 262.49.369 262.49.370 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 15 kg not suitable not suitable 300 N

Type Keku® Push-in fittings Unhook stroke Inspection of fittings

Type Hospa Varianta Material Standard-Type Temperatur range Forward Wall panel Floor panel Ceiling panel tension and compression

Frame component AS 262.50.368 262.50.377 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 kg 20 kg not suitable 300 N

Frame component ASR 262.50.390 262.50.391 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 kg 20 Kg not suitable 300 N

Panel component AS 262.50.359 262.50.358 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 kg 20 kg not suitable 300 N

Type Keku® Double partition fitting Unhook stroke Inspection of fittings

Type Hospa Varianta Material Standard-Type Temperatur range up Wall panel Floor panel Ceiling panel tension and compression

Angled component AD15 262.51.380 262.51.381 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 kg not suitable not suitable 300 N

Angled component AD30 262.51.390 262.51.391 Polycarbonat 2600/2800 -100 bis +135°C 25 mm 20 kg not suitable not suitable 300 N

max. load capacity of a pair of fittings

max. load capacity of a pair of fittings

max. load capacity of a pair of fittings

The fire class of the components depends on the materials of the processed panelling and cladding

materials.The Keku® R aluminium room system is regarded as not flammable. Fire class According to a

uniform statement from the material testing institutes, fittings must generally only be assessed with

regard to fire resistance in accordance with DIN 4102 in the installed condition and in connection with

a component.This means that the Keku® fittings are also not tested as individual components in the

non-installed condition and are not regarded as materials such as the sub-construction or the panelling

and finishing material, which is evaluated in accordance with fire protection class A1, A2 (not

flammable) or B1 (hardly inflammable), B2 (normally inflammable) or B3 (easily flammable).

The processing of the Keku® system requires conscientious, skilful handling. Trial assemblies are recommended for

special loads and unusual designs. Persons unfamiliar with the trade and maintenance personnel must be provided

with instruction about the handling of the inspection panels.. At least 4 pairs of fittings are required when hanging a

rectangular panel. The spacing depends on the panel thickness as well as the arrangement of attachment points and

should not exceed 600 mm. For uniform distribution of the load, the fittings must be positioned precisely.

Regarding the number of different applications, we recommend that the worker performs a trial assembly. Load

carrying plastic fittings should not be treated with chemical solutions or aggressive greases. The basic material for

the Keku® suspension, slide-on and double partition fittings is a polycarbonate (PC). A certified quality assurance

system monitors all manufacturing processes. A structural FEM calculation confirms that the assemblies have been

made using the material that we have specified. The Keku® fittings and the Keku® R room system fulfil all

requirements of the latest version of the REACH and RoHs legislation. The legal SCCP limit - short chain chlorinated

paraffins - is complied with.

zurück

zurück

Object advice

KUSANKE Beschlagtechnik GmbH & Co. KG Im Wiesental 37 58513 Lüdenscheid Telefon: +49 (0) 2351 – 9508 - 0 Telefax: +49 (0) 2351 – 9508 - 20E-Mail: [email protected]

Distribution

Keku® Fitting and room system

SIMPLY PERFECT

HÄFELE GmbH & Co KG Postfach 1237 72192 NagoldTelefon: +49 (0) 7452 – 95 - 0 Telefax: +49 (0) 7452 – 95 - 200E-Mail: [email protected]