25
Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 Features • Exact and highly reliable measurement of superheated steam up to 752 °F • Installation and start-up do not require any pipe work nor any process interruptions • Volumetric and mass flow rate available without additional steam calculator • Non-invasive and wear-free measurement without pressure loss • Maintenance-free acoustic coupling using permanent cou- pling foil • Bi-directional measurement over a wide turndown ratio - up to 25:1 • Advanced self-diagnosis and possibilities for event-based triggering of data recording • Bidirectional communication and support of common bus technologies • Transmitter and transducers are separately calibrated (trace- able to national standards) • The measurement is zero point stable and drift free Applications • Process control • Consumption metering • Check metering FLUXUS G722ST-HT (aluminum housing) FLUXUS G722ST-HT (stainless steel housing) WaveInjector Superheated steam flow measurement Permanently installed non-invasive ultrasonic measuring system

Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification

FLUXUS G722ST-HT

TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Features

• Exact and highly reliable measurement of superheated steam up to 752 °F

• Installation and start-up do not require any pipe work nor any process interruptions

• Volumetric and mass flow rate available without additional steam calculator

• Non-invasive and wear-free measurement without pressure loss

• Maintenance-free acoustic coupling using permanent cou-pling foil

• Bi-directional measurement over a wide turndown ratio - up to 25:1

• Advanced self-diagnosis and possibilities for event-based triggering of data recording

• Bidirectional communication and support of common bus technologies

• Transmitter and transducers are separately calibrated (trace-able to national standards)

• The measurement is zero point stable and drift free

Applications

• Process control

• Consumption metering

• Check metering

FLUXUS G722ST-HT (aluminum housing)

FLUXUS G722ST-HT (stainless steel housing)

WaveInjector

Superheated steam flow measurement

Permanently installed non-invasive ultrasonic measuring system

Page 2: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus2

Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Measurement principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Calculation of volumetric flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72" pipe mounting kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Transducer selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Transducer order code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Transducer mounting fixture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Coupling materials for transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Connection systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Junction box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232" pipe mounting kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Clamp-on temperature probe (optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Fixation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Junction box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Page 3: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

3TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Function

Measurement principleThe flow velocity of the fluid is measured using the correlation principle. 2 pairs of ultrasonic transducers are mounted oneafter the other at a distance ∆x on the pipe. The transducer pairs form the measuring barriers A and B. Ultrasonic signalsare alternately emitted by the emitters A1 and B1 and received by the respective receivers A2 and B2. The ultrasonic signalsare modulated regarding amplitude and phase by the swirls of the turbulent flowing fluid. Since the swirls move with theflow, they pass the measuring barriers A und B with a time offset ∆t, so that the modulation patterns of the ultrasonic sig-nals of measuring barrier A and B are also offset by ∆t. This time offset ∆t is measured by means of cross correlation ofthe modulation signals.

Calculation of volumetric flow rate = A · v = A · kRe ·

where

Measuring setup

Time offset of the modulation patterns ∆t

- operating volumetric flow rate

A - cross-sectional pipe area

v - flow velocity

kRe - fluid mechanics calibration factor

∆x - distance between measuring barriers

∆t - time offset of the modulation patterns

A1 B1

A2 B2

∆x

A B

∆t time

mo

du

latio

n

V·xt-------

Page 4: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus4

Transmitter

Technical data

FLUXUS G722ST-NN0*A FLUXUS G722ST-NN0*S FLUXUS G722ST-A20*S FLUXUS G722ST-F20*S

design standard field devicenonEx

field devicewith stainless steel housingnonEx

field devicewith stainless steel housingzone 2

field devicewith stainless steel housingFM Class I Div. 2

application high-temperature steam measurement1

measurementmeasurement principle

cross correlation

flow velocity ft/s depending on the applicationrepeatability ±1 % MV (Re > 60 000)

±3 % MV (Re 10 000…60 000)Reynolds number Re > 10 000fluid saturated steam, superheated steamfluid pressure psia 15 to 1595fluid temperature °F 212 to 752measurement uncertainty (volumetric flow rate)measurement uncer-tainty at the measu-ring point

±3 % MV (Re > 60 000)±4 % MV (Re 10 000…60 000)

transmitterpower supply • 100 to 230 V/50 to 60 Hz or

• 20 to 32 V DC or

• 11 to 16 V DCpower consumption W < 15number of measuring channels

1 (2 transducer pairs of the same type required according to measuring setup, see section "Measurement principle")

damping s 0 to 100 (adjustable)measuring cycle Hz 0.7 to 2 (depending on the application)response time s 10 to 35 (depending on the application)housing material aluminum, powder coated stainless steel 316Ldegree of protection IP65 IP65 IP66 IP65dimensions inch see dimensional drawingweight lb 11.9 11.2fixation wall mounting, optional: 2" pipe mountingambient temperature °F -4 to +131/140 -4 to +131/140 -40 to +140 (< -4 °F without

operation of the display)-4 to +131/140

display 128 x 64 dots, backlightmenu language English, German, French, Spanish, Dutch, Russian, Polish, Turkish, Italianexplosion protection• ATEX/IECExmarking - -

Ex nA nC ic IIC T4 GcEx tb IIIC T120 °C DbTa -40...+60 °C

-

certification ATEX - - IBExU11ATEX1015 -certification IECEx - - IECEx IBE 11.0008 -• FMmarking - - - G722**-F20*S2,

G722**-F20*S3:

NI/Cl. I,II,III/Div. 2/GP. A,B,C, D,E,F,G/T5

G722**-F20*S1:

NI/Cl. I,II,III/Div. 2/GP. A,B,C, D,E,F,G/T4A

measuring functionsphysical quantities operating volumetric flow rate, mass flow rate, flow velocitytotalizer volume, massdiagnostic functions crest factor, peak width, symmetry of amplification1 test measurement to validate the application required in advance2 outside the explosive atmosphere (housing cover open)3 with inputs and including parametrization of the transmitter

II3GII2D

0637

Page 5: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

5TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

communication interfacesservice interfaces measured value transmission, parametrization of the transmitter:

• USB2

• LAN2

process interfaces max. 1 option:

• RS485 (ASCII sender)

• Modbus RTU3

• BACnet MS/TP

• HART3

• Profibus PA3

• FF H13

• Modbus TCP3

• BACnet IP

max. 1 option:

• RS485 (ASCII sender)

• Modbus RTU3

• BACnet MS/TP

• HART3

• Profibus PA3

• FF H13

• Modbus TCP3

• BACnet IP

max. 1 option:

• RS485 (ASCII sender)

• Modbus RTU3

• BACnet MS/TP

• HART3

• Profibus PA3

• FF H13

• Modbus TCP3

• BACnet IP

max. 1 option:

• RS485 (ASCII sender)

• Modbus RTU3

• BACnet MS/TP

• HART3

• Profibus PA3

• FF H13

• Modbus TCP3

• BACnet IPaccessoriesdata transmission kit USB cablesoftware • FluxDiagReader: reading of measured values and parameters, graphical presentation

• FluxDiag (optional): reading of measurement data, graphical presentation, report generation, parametrization of the transmitterdata loggerloggable values all physical quantities, totalized physical quantities and diagnostic valuescapacity max. 800 000 measured valuesoutputs

The outputs are galvanically isolated from the transmitter.number on request• switchable current output

All switchable current outputs are jointly switched to active or passive.range mA 4 to 20 (3.2 to 22)accuracy 0.04 % MV ±3 μAactive output Rext < 350 Ωpassive output Uext = 8 to 30 V, depending on Rext (Rext < 1 kΩ at 30 V)• HARTrange mA 4 to 20accuracy 0.1 % MV ±15 μAactive output Uint = 24 V, Rext < 500 Ωpassive output Uext = 10 to 24 V DC, depending on Rext (Rext < 1 kΩ at 24 V)• voltage outputrange V 0 to 1 or 0 to 10accuracy 0 to 1 V: 0.1 % MV ±1 mV

0 to 10 V: 0.1 % MV ±10 mVinternal resistance Rint = 500 Ω• digital outputFunction • frequency output

• binary output

• pulse outputnumber 3operating parame-ters

5 to 30 V/< 100 mA

frequency output• range kHz 0 to 5binary output• binary output as

alarm outputlimit, change of flow direction or error

pulse output• functions mainly for totalizing• pulse value units 0.01 to 1000• pulse width ms 0.05 to 1000

FLUXUS G722ST-NN0*A FLUXUS G722ST-NN0*S FLUXUS G722ST-A20*S FLUXUS G722ST-F20*S

1 test measurement to validate the application required in advance2 outside the explosive atmosphere (housing cover open)3 with inputs and including parametrization of the transmitter

Page 6: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus6

inputsThe inputs are galvanically isolated from the transmitter.

number max. 4, on request• temperature inputtype Pt100/Pt1000connection 4-wirerange °F -238 to +1040resolution K 0.01accuracy ±0.01 % MV ±0.03 K• current inputaccuracy 0.1 % MV ±10 μAactive input Uint = 24 V, Rint = 50 Ω, Pint < 0.5 W, not short-circuit proof• range mA 0 to 20passive input Rint = 50 Ω, Pint < 0.3 W• range mA -20 to +20• voltage inputrange V 0 to 1accuracy 0.1 % MV ±1 mVinternal resistance Rint = 1 MΩ

FLUXUS G722ST-NN0*A FLUXUS G722ST-NN0*S FLUXUS G722ST-A20*S FLUXUS G722ST-F20*S

1 test measurement to validate the application required in advance2 outside the explosive atmosphere (housing cover open)3 with inputs and including parametrization of the transmitter

Page 7: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

7TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Dimensions

*721**-****A

*721**-****S

3.7

12.6

thread: 6x M20 x 1.5 cable gland: max. 6x 1/2 NPT

10.

04

6.5

2

7.49

wall mount

0.35

x 0

.2ø0

.24

0.35 x 0.2

in inch

3.6

6

10.0

4

9.45

cable gland: max. 6x 1/2 NPS with counter nut

11.0

2

3.4

3

fixing holes for wall mounting

12.6

in inch

Page 8: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus8

2" pipe mounting kit

*721**-****A

order code:ACC-PE-G721-/PMK4

*721**-****S

order code:ACC-PE-G721-/PMK6

Page 9: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

9TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Terminal assignment

*72*

power supply1

terminal connection (AC) connection (DC)PE earth earth

N(-) neutral -

L(+) phase +

transducers

transducer cable (transducers ****LI*), extension cable transducer cable (transducers *****52)measuring channel A measuring channel B measuring chan-

nel Ameasuring chan-nel B

terminal connection terminal connection transducer terminal connectionAV signal BV signal X_AV X_BV SMB connector

AVS shield BVS shield

ARS shield BRS shield X_AR X_BR SMB connector

AR signal BR signal

outputs1, 2

terminal connection terminal connection communication inter-face

P1+ to P4+P1- to P4-

current output, voltage output, HART (P1) A+ signal + • RS4851

• Modbus RTU1

• BACnet MS/TP1

• Profibus PA1

• FF H11

B- signal -

P5a to P7aP5b to P7b

digital output S shield

USB type BHi-Speed USB 2.0 Device

• service (FluxDiag/FluxDiagReader)

LAN RJ4510/100 Mbps Ethernet

• service (FluxDiag/FluxDiagReader)

• BACnet IP

• Modbus TCP

analog inputs1, 2

temperature probe passive sensor active sensorterminal direct connection connection with extension

cableconnection connection

T1a to T4a red white not connected not connectedT1A to T4A red black - +T1b to T4b white red + not connectedT1B to T4B white green not connected -S1, S3 shield - not connected not connected

binary inputs1, 2

terminalP1+ to P2+, P1- to P2-1 сable (by customer):

- e.g., flexible wires, with insulated wire ferrules, wire cross-section: AWG14 to 24- outer diameter of the cable (*721**-****S with ferrite nut): max. 0.3 inch

2 The number, type and terminal assignment are customized.

A+B-P1+P2+P3+P4+P5aP6aP7a

S S P1-P2-P3-P4-P5bP6bP7bX2 X3

X_AV X_AR X_BV X_BR

T1A

T1B

S1T2A

T2B

T3A

T3B

S3

T4B

T4A

T1a

T1b

S1T2a

T2b

T3a

T3b

S3

T4b

T4a

N(-)

PE L(+)

AV AVS

AGN

ARS

AR

BVBVS

BGN

BRS

BR

LAN USB

*72***-****S *72***-****Aequipotential bonding terminal

Page 10: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus10

Transducers

Transducer selection

transducer order code

GSG-E 5.9 7.9 35.4 51.2

GSK-E 2.4 3.1 14.2 20.5

GSM-E 1.3 1.6 7.1 10.2

GSP-E 0.63 0.79 3.5 5.1

GSQ-E 0.31 0.39 1.8 2.6

0.2 0.4 2 4 20 40

inner pipe diameter [inch]

transducer order code (zone 2 - FM Class I Div. 2 - nonEx)

GSG-E 212 338

GSG-N and WaveInjector 338 752

GSK-E 212 338

GSK-N and WaveInjector 338 752

GSM-E 212 450

GSM-N and WaveInjector 450 752

GSP-E 212 450

GSP-N and WaveInjector 450 752

GSQ-E 212 392

GSQ-N and WaveInjector 392 752

212 392 572 752max. pipe surface temperature [°F]

transducer order code (zone 1)

GSG-E 212 284

GSG-N and WaveInjector 284

GSK-E 212 284

GSK-N and WaveInjector 284

GSM-E 212 437

GSM-N and WaveInjector 437

GSP-E 212 437

GSP-N and WaveInjector 437

GSQ-E 212 392

GSQ-N and WaveInjector 392

212 392 572 752max. pipe surface temperature [°F]

recommended possible

Page 11: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

11TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Transducer order code

Each measuring system requires 2 sets of ultrasonic transducers of the same type.

1, 2 3 4 5, 6 7, 8 9 to 11 no. of character

tra

ns

du

cer

tran

sdu

cer

freq

uen

cy

- am

bie

nt

tem

pe

ratu

re

exp

los

ion

pro

tec

tio

n

co

nn

ec

tio

n s

ys

tem

- ext

en

sio

n c

able

/ op

tio

n

de

scr

ipti

on

GS set of ultrasonic flow transducers, shear waveG 0.2 MHzK 0.5 MHzM 1 MHzP 2 MHzQ 4 MHz

N normal temperature rangeE extended temperature range

NN not explosion-proofA2 ATEX zone 2/IECEx zone 2A1 ATEX zone 1/IECEx zone 1F2 FM Class I Div. 2

TS direct connection or connection via junction boxXXX 0 m: without extension cable

> 0 m: with extension cableLC long transducer cableOS housing with stainless steel 316

Page 12: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus12

Technical data

Shear wave transducers (zone 2 - FM Class I Div. 2 - nonEx, TS)

order code GSG-N**TS/** GSK-N**TS/** GSM-N**TS/** GSP-N**TS/** GSQ-N**TS/**technical type G(DL)G1N52 G(DL)K1N52 G(DL)M2N52 G(DL)P2N52 G(DL)Q2N52transducer frequency MHz 0.2 0.5 1 2 4inner pipe diameter dmin. extended inch 7.1 2.8 1.5 0.71 0.35min. recommended inch 9.4 3.9 1.9 0.94 0.47max. recommended inch 36.2 14.6 7.1 3.5 1.8max. extended inch 51.2 20.5 10.2 5.1 2.6pipe wall thicknessmin. inch 0.44 0.17 0.09 0.04 0.02materialhousing PEEK with stainless steel cover 304, ***-*****/OS: 316Lcontact surface PEEKdegree of protection NEMA 6transducer cabletype 1699length ft 16 13 9length (***-*****/LC) ft 29dimensionslength l inch 5.1 4.98 2.52 1.57width b inch 2.01 2.01 1.26 0.87height h inch 2.64 2.66 1.59 1dimensional drawing

weight (without cable)

lb 1 0.79 0.15 0.04

pipe surface temperaturemin. °F -40max. °F +266ambient temperaturemin. °F -40max. °F +266temperature com-pensation

x

explosion protection• ATEX/IECExorder code GSG-NA2TS/** GSK-NA2TS/** GSM-NA2TS/** GSP-NA2TS/** GSQ-NA2TS/**pipe surface temperature (Ex)• min. °C -55• max. °C gas: +190, dust: +180marking

Ex nA IIC T6...T3 GcEx tb IIIC T80 °C...T185 °C Db

certification ATEX IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X• FMorder code GSG-NF2TS/** GSK-NF2TS/** GSM-NF2TS/** GSP-NF2TS/** GSQ-NF2TS/**pipe surface temperature (Ex)• min. °F -40• max. °F +257 +374degree of protection IP66marking NI/Cl. I,II,III/Div. 2 /

GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

l

hb

l

hb

l

hb

l

hb

II3GII2D0637

Page 13: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

13TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Shear wave transducers (zone 2 - FM Class I Div. 2 - nonEx, TS, extended temperature range)

order code GSG-ENNTS/** GSK-ENNTS/** GSM-E**TS/** GSP-E**TS/** GSQ-E**TS/**technical type G(DL)G1E52 G(DL)K1E52 G(DL)M2E52 G(DL)P2E52 G(DL)Q2E52transducer frequency MHz 0.2 0.5 1 2 4inner pipe diameter dmin. extended inch 5.9 2.4 1.3 0.63 0.31min. recommended inch 7.9 3.1 1.6 0.79 0.39max. recommended inch 35.4 14.2 7.1 3.5 1.8max. extended inch 51.2 20.5 10.2 5.1 2.6pipe wall thicknessmin. inch 0.44 0.17 0.09 0.04 0.02materialhousing PPSU with stainless steel cover 304

, ***-*****/OS: 316L PI with stainless steel cover 304, ***-*****/OS: 316L

contact surface PPSU PIdegree of protection IP65 NEMA 4transducer cabletype 1699 6111length ft 16 13 9length (***-*****/LC) ft 29 29dimensionslength l inch 5.1 2.52 1.57width b inch 2.01 1.26 0.87height h inch 2.64 1.59 1dimensional drawing

weight (without cable)

lb 1.8 0.15 0.04

pipe surface temperaturemin. °F 212 212 212max. °F 338 4501 392ambient temperaturemin. °F -40 -22 -22max. °F +338 +104

+1402

+3923

+392

temperature com-pensation

x x

explosion protection• ATEX/IECExorder code - - GSM-EA2TS/** GSP-EA2TS/** GSQ-EA2TS/**pipe surface temperature (Ex)• min. °C - - -45• max. °C - - gas: +2351, dust: +2251

marking - -

Ex nA IIC T6...T2 GcEx tb IIIA T80 °C...230 °C Db

certification ATEX - - IBExU10ATEX1163 Xcertification IECEx - - IECEx IBE 12.0005X• FMorder code - - GSM-EF2TS/** GSP-EF2TS/** GSQ-EF2TS/**pipe surface temperature (Ex)• min. °F - - -40• max. °F - - +4551

degree of protection - - IP66marking - - NI/Cl. I,II,III/Div. 2 /

GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

1 > +200 °C/+392 °F:PermaLok without cover; quick release clasps and tension straps (nonEx)observe the insulation instructionEx: ambient temperature max. +40 °C/+104 °F

2 pipe surface temperature +200 to +232 °C/+392 to +450 °F: quick release clasps and tension straps3 pipe surface temperature max. +200 °C/+392 °F

l

bh

l

hb

l

hb

II3GII2D0637

Page 14: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus14

Shear wave transducers (zone 1, TS)

order code GSG-N*1TS/** GSK-N*1TS/** GSM-N*1TS/** GSP-N*1TS/** GSQ-N*1TS/**technical type G(DL)G1N81 G(DL)K1N81 G(DL)M2N81 G(DL)P2N81 G(DL)Q2N81transducer frequency MHz 0.2 0.5 1 2 4inner pipe diameter dmin. extended inch 7.1 2.8 1.5 0.71 0.35min. recommended inch 9.4 3.9 1.9 0.94 0.47max. recommended inch 36.2 14.6 7.1 3.5 1.8max. extended inch 51.2 20.5 10.2 5.1 2.6pipe wall thicknessmin. inch 0.44 0.17 0.09 0.04 0.02materialhousing PEEK with stainless steel cover 304 , ***-*****/OS: 316L contact surface PEEKdegree of protection IP65 IP66 IP65transducer cabletype 1699length ft 16 13 9length (***-*****/LC) ft 29dimensionslength l inch 5.1 4.98 2.52 1.57width b inch 2.01 2.01 1.26 0.87height h inch 2.64 2.66 1.59 1dimensional drawing

weight (without cable)

lb 1 0.79 0.15 0.04

pipe surface temperaturemin. °F -40max. °F +266ambient temperaturemin. °F -40max. °F +266temperature com-pensation

x

explosion protection• ATEX/IECExorder code GSG-NA1TS/** GSK-NA1TS/** GSM-NA1TS/** GSP-NA1TS/** GSQ-NA1TS/**pipe surface temperature (Ex)• min. °C -55• max. °C +180marking

Ex q IIC T6...T3 GbEx tb IIIC T80 °C...T185 °C Db

certification ATEX IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X

l

bh

l

bh

l

bh

l

bh

0637 II2GII2D

Page 15: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

15TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Shear wave transducers (zone 1, TS, extended temperature range)

order code GSG-E*1TS/** GSK-E*1TS/**technical type G(DL)G1E83 G(DL)K1E83transducer frequency MHz 0.2 0.5inner pipe diameter dmin. extended inch 5.9 2.4min. recommended inch 7.9 3.1max. recommended inch 35.4 14.2max. extended inch 51.2 20.5pipe wall thicknessmin. inch 0.44 0.17materialhousing PPSU with stainless steel cover 304

, ***-*****/OS: 316L contact surface PPSUdegree of protection IP65transducer cabletype 1699length ft 16length (***-*****/LC) ft 29dimensionslength l inch 5.1width b inch 2.01height h inch 2.64dimensional drawing

weight (without cable)

lb 1.8

pipe surface temperaturemin. °F 212max. °F 338ambient temperaturemin. °F -40max. °F +338temperature com-pensation

x

explosion protection• ATEX/IECExorder code GSG-EA1TS/** GSK-EA1TS/**pipe surface temperature (Ex)• min. °C -50• max. °C +140marking

Ex q IIC T6...T3 GbEx tb IIIC T80 °C...T145 °C Db

certification ATEX IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X

l

bh

II2GII2D0637

Page 16: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus16

Shear wave transducers (zone 1, TS, extended temperature range)

order code GSM-E*1TS/** GSP-E*1TS/** GSQ-E*1TS/**technical type G(DL)M2E85 G(DL)P2E85 G(DL)Q2E85transducer frequency MHz 1 2 4inner pipe diameter dmin. extended inch 1.3 0.63 0.31min. recommended inch 1.6 0.79 0.39max. recommended inch 7.1 3.5 1.8max. extended inch 10.2 5.1 2.6pipe wall thicknessmin. inch 0.09 0.04 0.02materialhousing PI with stainless steel cover 304, ***-*****/OS: 316Lcontact surface PIdegree of protection IP66 IP56transducer cabletype 6111length ft 13 9length (***-*****/LC) ft 29dimensionslength l inch 2.52 1.57width b inch 1.26 0.87height h inch 1.59 1dimensional drawing

weight (without cable)

lb 0.15 0.04

pipe surface temperaturemin. °F 212 212max. °F 4501 392ambient temperaturemin. °F -22 -22max. °F +104

+3922+392

temperature com-pensation

x

explosion protection• ATEX/IECExorder code GSM-EA1TS/** GSP-EA1TS/** GSQ-EA1TS/**pipe surface temperature (Ex)• min. °C -45• max. °C +2251

marking

Ex q IIC T6...T2 GbEx tb IIIA T80 °C...T230 °C Db

certification ATEX IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X1 > +200 °C/+392 °F:

PermaLokobserve the insulation instructionambient temperature max. +40 °C/+104 °F

2 pipe surface temperature max. +200 °C/+392 °F

l

hb

l

hb

II2GII2D0637

Page 17: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

17TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Transducer mounting fixture

Order code

1, 2 3 4 5 6 7 to 9 no. of charactertr

ansd

uce

r m

ou

nti

ng

fi

xtu

re

tra

ns

du

cer

- me

as

ure

me

nt

arr

an

ge

men

t

siz

e

- fix

ati

on

ou

ter

pip

e d

iam

eter

/ op

tio

n

de

scr

ipti

on

PL PermaLokWI transducer box for WaveInjector

K transducers with transducer frequency G, KM transducers with transducer frequency M, PQ transducers with transducer frequency Q

D diagonal arrangement/direct modeS smallL large

S tension strapsSK1 0.5 to 2.5 inchSK2 3 to 6 inch

SK3 8 to 10 inch

SK4 12 to 18 inch

SK5 20 to 36 inch

SK6 42 to 100 inch

IP68 for transducers with degree of protection IP68OS housing with stainless steel 316Z special design

Page 18: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus18

PermaLok PL

material: stainless steel 316

quick release clasps and tension straps

material: stainless steel 410, 200

transducer box WI for WaveInjector

see Technical specificationTSWaveInjectorVx-x

transducer box

Page 19: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

19TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Coupling materials for transducers

type ambient temperature remark

°Fcoupling pad type VT 14 to +392 fluid temperature 392 °F: min. 2 years

coupling pad type TF 392 to 464

coupling compound type E -22 to +392 in combination with type VT only

coupling compound type H -22 to +482 in combination with type TF only

coupling pad type A max. 536 WaveInjector

coupling pad type B 536 to 752 WaveInjector

Page 20: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus20

Connection systems

Cable

connection system TS

connection with extension cable direct connection transducerstechnical type*****8*

*****52

transducer cable

type 1699 6111weight lb/ft 0.06 0.06ambient temperature °F -67 to +392 -148 to +437propertiescable jacketmaterial PTFE PFAouter diameter inch 0.11 0.11thickness inch 0.01 0.02color brown whiteshield x xsheathmaterial stainless steel 304 stainless steel 304

option OS: 316Ti option OS: 316Tiouter diameter inch 0.31 0.31

extension cable

type 2615 5245weight lb/ft 0.12 0.26ambient temperature °F -22 to +158 -22 to +158properties halogen free

fire propagation test according to IEC 60332-1

combustion test according to IEC 60754-2

halogen free

fire propagation test according to IEC 60332-1

combustion test according to IEC 60754-2

cable jacketmaterial PUR PURouter diameter inch max. 0.47 max. 0.47thickness inch 0.08 0.08color black blackshield x xsheathmaterial - steel wire braid with copolymer

sheathouter diameter inch - max. 0.61

tra

nsm

itte

r

JB01 x

l

tra

nsm

itte

r

x

tra

nsm

itter

JB02, JB03, JB04x

l

tran

smitt

er

x

Page 21: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

21TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Cable length

transducer frequency

F, G, H, K M, P Q S

connection system TStransducerstechnical type

x l x l x l x l

*(DR)***8* ft 16 ≤ 984 13 ≤ 984 9 ≤ 295 - -option LC:*(LT)***8*

ft 29 ≤ 984 29 ≤ 984 29 ≤ 295 - -

*(DR)***5* ft 16 ≤ 984 13 ≤ 984 9 ≤ 295 6 ≤ 131option LC:*(LT)***5*

ft 29 ≤ 984 29 ≤ 984 29 ≤ 295 - -

x = transducer cable length

l = max. length of extension cable (depending on the application)

Page 22: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus22

Junction box

Technical data

JB01S4E3M, JBP2, JBP3

weight lb 2.6 lbfixation wall mounting

optional: 2" pipe mountingmaterialhousing stainless steel 316Lgasket siliconedegree of protection NEMA 6ambient temperaturemin. °F -40max. °F +176explosion protection• ATEX/IECEx (zone 1)junction box JB01S4E3Mmarking

Ex eb mb IIC T6...T4 GbEx tb IIIC T100 °C DbTa -40...+70/80 °C

certification ATEX IBExU06ATEX1161certification IECEx IECEx IBE 08.0006type of protection gas: increased safety

decoupled network: encapsula-tion

dust: protection by enclosure• ATEX (zone 2)junction box JBP2marking

II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C

JB02, JB03, JB04

weight lb 2.6 lbfixation wall mounting

optional: 2" pipe mountingmaterialhousing stainless steel 316Lgasket siliconedegree of protection IP67ambient temperaturemin. °F -40max. °F +176explosion protection• ATEXjunction box JB02marking

II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C

• FMjunction box JB04marking NI/Cl. I,II,III/Div. 2 /

GP A,B,C,D,E,F,G/T6 Ta = -40...+60 °C

Connection

Transducers

Extension cable

terminal strip terminal connection transducer

KL1 V signalVS internal shieldRS internal shieldR signal

terminal strip terminal connection

KL2 TV signalTVS internal shieldTRS internal shieldTR signal

II2GII2D0637

Connection

Transducers

Extension cable

terminal connection transducer

XV SMB connector

XR SMB connector

terminal strip terminal connection

KL2 TV signalTVS internal shieldTRS internal shieldTR signal

Page 23: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

Technical specification FLUXUS G722ST-HT

23TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01

Dimensions

2" pipe mounting kit

JB0*, JBP*

JB**

order code:ACC-PE-GNNN-/JBPMK4

6.85

4.69

0.08

wall mounting holder

2.76

6.44

6.1

4Ø 0.35

thread: 3x M20 x 1.5cable gland: max. 2x 1/2 NPT

in inch

Page 24: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLUXUS G722ST-HT Technical specification

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus24

Clamp-on temperature probe (optional)

Technical data

Fixation

Junction box

PT13N

design clamp-ontype Pt1000connection 4-wiremeasuring range °F -40 to +392accuracy T ±(0.27 °F + 2 . 10-3 . (|T [°F]| -

32 °F))class A

accuracy ∆T(2x Pt matched according to EN 1434-1)

≤ 0.03 °F (at 50 °F)

housing 360 brass alloydegree of protection NEMA 4dimensions

length l inch 0.79width b inch 0.59height h inch 0.49dimensional drawing

weight lb 0.437accessories

thermal conductivity foil 482 °F

x

tension strap PT13N

material: stainless steel 301, 410

thermal insulation necessary

Connection system

Connection

Cable

connection with extension cable direct connection

temperature probe

red

red

white

white

temperature probe extension cable

type 4 x 24 AWG 4 x 18 AWGstandard length ft 20 -max. length ft - 656cable jacket PTFE LS PVC

junction box

extension cable

h

lb

4.72”

½” NPT

1.34"

1.18”1.18”

Top View

Side View

Connection

temperature probe extension cable

red whitered blackwhite greenwhite red

Page 25: Technical specification FLUXUS G722ST-HT...Technical specification FLUXUS G722ST-HT TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01 3 Function Measurement principle The flow velocity of the

FLEXIM AMERICAS CorporationEdgewood, NY 11717

USA

Tel.:(631) 492-2300Fax:(631) 492-2117

internet: www.flexim.come-mail: [email protected]

1-888-852-7473

Subject to change without prior notice.Errors excepted.

FLUXUS is a registered trademark of FLEXIM GmbH.

Copyright (©) FLEXIM GmbH 2020

2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus