Technical specification
FLUXUS G722ST-HT
TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Features
• Exact and highly reliable measurement of superheated steam up to 752 °F
• Installation and start-up do not require any pipe work nor any process interruptions
• Volumetric and mass flow rate available without additional steam calculator
• Non-invasive and wear-free measurement without pressure loss
• Maintenance-free acoustic coupling using permanent cou-pling foil
• Bi-directional measurement over a wide turndown ratio - up to 25:1
• Advanced self-diagnosis and possibilities for event-based triggering of data recording
• Bidirectional communication and support of common bus technologies
• Transmitter and transducers are separately calibrated (trace-able to national standards)
• The measurement is zero point stable and drift free
Applications
• Process control
• Consumption metering
• Check metering
FLUXUS G722ST-HT (aluminum housing)
FLUXUS G722ST-HT (stainless steel housing)
WaveInjector
Superheated steam flow measurement
Permanently installed non-invasive ultrasonic measuring system
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus2
Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Measurement principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Calculation of volumetric flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72" pipe mounting kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Transducer selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Transducer order code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Transducer mounting fixture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Coupling materials for transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Connection systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Junction box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232" pipe mounting kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Clamp-on temperature probe (optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Fixation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Junction box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Technical specification FLUXUS G722ST-HT
3TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Function
Measurement principleThe flow velocity of the fluid is measured using the correlation principle. 2 pairs of ultrasonic transducers are mounted oneafter the other at a distance ∆x on the pipe. The transducer pairs form the measuring barriers A and B. Ultrasonic signalsare alternately emitted by the emitters A1 and B1 and received by the respective receivers A2 and B2. The ultrasonic signalsare modulated regarding amplitude and phase by the swirls of the turbulent flowing fluid. Since the swirls move with theflow, they pass the measuring barriers A und B with a time offset ∆t, so that the modulation patterns of the ultrasonic sig-nals of measuring barrier A and B are also offset by ∆t. This time offset ∆t is measured by means of cross correlation ofthe modulation signals.
Calculation of volumetric flow rate = A · v = A · kRe ·
where
Measuring setup
Time offset of the modulation patterns ∆t
- operating volumetric flow rate
A - cross-sectional pipe area
v - flow velocity
kRe - fluid mechanics calibration factor
∆x - distance between measuring barriers
∆t - time offset of the modulation patterns
A1 B1
A2 B2
∆x
A B
∆t time
mo
du
latio
n
V·xt-------
V·
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus4
Transmitter
Technical data
FLUXUS G722ST-NN0*A FLUXUS G722ST-NN0*S FLUXUS G722ST-A20*S FLUXUS G722ST-F20*S
design standard field devicenonEx
field devicewith stainless steel housingnonEx
field devicewith stainless steel housingzone 2
field devicewith stainless steel housingFM Class I Div. 2
application high-temperature steam measurement1
measurementmeasurement principle
cross correlation
flow velocity ft/s depending on the applicationrepeatability ±1 % MV (Re > 60 000)
±3 % MV (Re 10 000…60 000)Reynolds number Re > 10 000fluid saturated steam, superheated steamfluid pressure psia 15 to 1595fluid temperature °F 212 to 752measurement uncertainty (volumetric flow rate)measurement uncer-tainty at the measu-ring point
±3 % MV (Re > 60 000)±4 % MV (Re 10 000…60 000)
transmitterpower supply • 100 to 230 V/50 to 60 Hz or
• 20 to 32 V DC or
• 11 to 16 V DCpower consumption W < 15number of measuring channels
1 (2 transducer pairs of the same type required according to measuring setup, see section "Measurement principle")
damping s 0 to 100 (adjustable)measuring cycle Hz 0.7 to 2 (depending on the application)response time s 10 to 35 (depending on the application)housing material aluminum, powder coated stainless steel 316Ldegree of protection IP65 IP65 IP66 IP65dimensions inch see dimensional drawingweight lb 11.9 11.2fixation wall mounting, optional: 2" pipe mountingambient temperature °F -4 to +131/140 -4 to +131/140 -40 to +140 (< -4 °F without
operation of the display)-4 to +131/140
display 128 x 64 dots, backlightmenu language English, German, French, Spanish, Dutch, Russian, Polish, Turkish, Italianexplosion protection• ATEX/IECExmarking - -
Ex nA nC ic IIC T4 GcEx tb IIIC T120 °C DbTa -40...+60 °C
-
certification ATEX - - IBExU11ATEX1015 -certification IECEx - - IECEx IBE 11.0008 -• FMmarking - - - G722**-F20*S2,
G722**-F20*S3:
NI/Cl. I,II,III/Div. 2/GP. A,B,C, D,E,F,G/T5
G722**-F20*S1:
NI/Cl. I,II,III/Div. 2/GP. A,B,C, D,E,F,G/T4A
measuring functionsphysical quantities operating volumetric flow rate, mass flow rate, flow velocitytotalizer volume, massdiagnostic functions crest factor, peak width, symmetry of amplification1 test measurement to validate the application required in advance2 outside the explosive atmosphere (housing cover open)3 with inputs and including parametrization of the transmitter
II3GII2D
0637
Technical specification FLUXUS G722ST-HT
5TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
communication interfacesservice interfaces measured value transmission, parametrization of the transmitter:
• USB2
• LAN2
process interfaces max. 1 option:
• RS485 (ASCII sender)
• Modbus RTU3
• BACnet MS/TP
• HART3
• Profibus PA3
• FF H13
• Modbus TCP3
• BACnet IP
max. 1 option:
• RS485 (ASCII sender)
• Modbus RTU3
• BACnet MS/TP
• HART3
• Profibus PA3
• FF H13
• Modbus TCP3
• BACnet IP
max. 1 option:
• RS485 (ASCII sender)
• Modbus RTU3
• BACnet MS/TP
• HART3
• Profibus PA3
• FF H13
• Modbus TCP3
• BACnet IP
max. 1 option:
• RS485 (ASCII sender)
• Modbus RTU3
• BACnet MS/TP
• HART3
• Profibus PA3
• FF H13
• Modbus TCP3
• BACnet IPaccessoriesdata transmission kit USB cablesoftware • FluxDiagReader: reading of measured values and parameters, graphical presentation
• FluxDiag (optional): reading of measurement data, graphical presentation, report generation, parametrization of the transmitterdata loggerloggable values all physical quantities, totalized physical quantities and diagnostic valuescapacity max. 800 000 measured valuesoutputs
The outputs are galvanically isolated from the transmitter.number on request• switchable current output
All switchable current outputs are jointly switched to active or passive.range mA 4 to 20 (3.2 to 22)accuracy 0.04 % MV ±3 μAactive output Rext < 350 Ωpassive output Uext = 8 to 30 V, depending on Rext (Rext < 1 kΩ at 30 V)• HARTrange mA 4 to 20accuracy 0.1 % MV ±15 μAactive output Uint = 24 V, Rext < 500 Ωpassive output Uext = 10 to 24 V DC, depending on Rext (Rext < 1 kΩ at 24 V)• voltage outputrange V 0 to 1 or 0 to 10accuracy 0 to 1 V: 0.1 % MV ±1 mV
0 to 10 V: 0.1 % MV ±10 mVinternal resistance Rint = 500 Ω• digital outputFunction • frequency output
• binary output
• pulse outputnumber 3operating parame-ters
5 to 30 V/< 100 mA
frequency output• range kHz 0 to 5binary output• binary output as
alarm outputlimit, change of flow direction or error
pulse output• functions mainly for totalizing• pulse value units 0.01 to 1000• pulse width ms 0.05 to 1000
FLUXUS G722ST-NN0*A FLUXUS G722ST-NN0*S FLUXUS G722ST-A20*S FLUXUS G722ST-F20*S
1 test measurement to validate the application required in advance2 outside the explosive atmosphere (housing cover open)3 with inputs and including parametrization of the transmitter
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus6
inputsThe inputs are galvanically isolated from the transmitter.
number max. 4, on request• temperature inputtype Pt100/Pt1000connection 4-wirerange °F -238 to +1040resolution K 0.01accuracy ±0.01 % MV ±0.03 K• current inputaccuracy 0.1 % MV ±10 μAactive input Uint = 24 V, Rint = 50 Ω, Pint < 0.5 W, not short-circuit proof• range mA 0 to 20passive input Rint = 50 Ω, Pint < 0.3 W• range mA -20 to +20• voltage inputrange V 0 to 1accuracy 0.1 % MV ±1 mVinternal resistance Rint = 1 MΩ
FLUXUS G722ST-NN0*A FLUXUS G722ST-NN0*S FLUXUS G722ST-A20*S FLUXUS G722ST-F20*S
1 test measurement to validate the application required in advance2 outside the explosive atmosphere (housing cover open)3 with inputs and including parametrization of the transmitter
Technical specification FLUXUS G722ST-HT
7TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Dimensions
*721**-****A
*721**-****S
3.7
12.6
thread: 6x M20 x 1.5 cable gland: max. 6x 1/2 NPT
10.
04
6.5
2
7.49
wall mount
0.35
x 0
.2ø0
.24
0.35 x 0.2
in inch
3.6
6
10.0
4
9.45
cable gland: max. 6x 1/2 NPS with counter nut
11.0
2
3.4
3
fixing holes for wall mounting
12.6
in inch
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus8
2" pipe mounting kit
*721**-****A
order code:ACC-PE-G721-/PMK4
*721**-****S
order code:ACC-PE-G721-/PMK6
Technical specification FLUXUS G722ST-HT
9TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Terminal assignment
*72*
power supply1
terminal connection (AC) connection (DC)PE earth earth
N(-) neutral -
L(+) phase +
transducers
transducer cable (transducers ****LI*), extension cable transducer cable (transducers *****52)measuring channel A measuring channel B measuring chan-
nel Ameasuring chan-nel B
terminal connection terminal connection transducer terminal connectionAV signal BV signal X_AV X_BV SMB connector
AVS shield BVS shield
ARS shield BRS shield X_AR X_BR SMB connector
AR signal BR signal
outputs1, 2
terminal connection terminal connection communication inter-face
P1+ to P4+P1- to P4-
current output, voltage output, HART (P1) A+ signal + • RS4851
• Modbus RTU1
• BACnet MS/TP1
• Profibus PA1
• FF H11
B- signal -
P5a to P7aP5b to P7b
digital output S shield
USB type BHi-Speed USB 2.0 Device
• service (FluxDiag/FluxDiagReader)
LAN RJ4510/100 Mbps Ethernet
• service (FluxDiag/FluxDiagReader)
• BACnet IP
• Modbus TCP
analog inputs1, 2
temperature probe passive sensor active sensorterminal direct connection connection with extension
cableconnection connection
T1a to T4a red white not connected not connectedT1A to T4A red black - +T1b to T4b white red + not connectedT1B to T4B white green not connected -S1, S3 shield - not connected not connected
binary inputs1, 2
terminalP1+ to P2+, P1- to P2-1 сable (by customer):
- e.g., flexible wires, with insulated wire ferrules, wire cross-section: AWG14 to 24- outer diameter of the cable (*721**-****S with ferrite nut): max. 0.3 inch
2 The number, type and terminal assignment are customized.
A+B-P1+P2+P3+P4+P5aP6aP7a
S S P1-P2-P3-P4-P5bP6bP7bX2 X3
X_AV X_AR X_BV X_BR
T1A
T1B
S1T2A
T2B
T3A
T3B
S3
T4B
T4A
T1a
T1b
S1T2a
T2b
T3a
T3b
S3
T4b
T4a
N(-)
PE L(+)
AV AVS
AGN
ARS
AR
BVBVS
BGN
BRS
BR
LAN USB
*72***-****S *72***-****Aequipotential bonding terminal
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus10
Transducers
Transducer selection
transducer order code
GSG-E 5.9 7.9 35.4 51.2
GSK-E 2.4 3.1 14.2 20.5
GSM-E 1.3 1.6 7.1 10.2
GSP-E 0.63 0.79 3.5 5.1
GSQ-E 0.31 0.39 1.8 2.6
0.2 0.4 2 4 20 40
inner pipe diameter [inch]
transducer order code (zone 2 - FM Class I Div. 2 - nonEx)
GSG-E 212 338
GSG-N and WaveInjector 338 752
GSK-E 212 338
GSK-N and WaveInjector 338 752
GSM-E 212 450
GSM-N and WaveInjector 450 752
GSP-E 212 450
GSP-N and WaveInjector 450 752
GSQ-E 212 392
GSQ-N and WaveInjector 392 752
212 392 572 752max. pipe surface temperature [°F]
transducer order code (zone 1)
GSG-E 212 284
GSG-N and WaveInjector 284
GSK-E 212 284
GSK-N and WaveInjector 284
GSM-E 212 437
GSM-N and WaveInjector 437
GSP-E 212 437
GSP-N and WaveInjector 437
GSQ-E 212 392
GSQ-N and WaveInjector 392
212 392 572 752max. pipe surface temperature [°F]
recommended possible
Technical specification FLUXUS G722ST-HT
11TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Transducer order code
Each measuring system requires 2 sets of ultrasonic transducers of the same type.
1, 2 3 4 5, 6 7, 8 9 to 11 no. of character
tra
ns
du
cer
tran
sdu
cer
freq
uen
cy
- am
bie
nt
tem
pe
ratu
re
exp
los
ion
pro
tec
tio
n
co
nn
ec
tio
n s
ys
tem
- ext
en
sio
n c
able
/ op
tio
n
de
scr
ipti
on
GS set of ultrasonic flow transducers, shear waveG 0.2 MHzK 0.5 MHzM 1 MHzP 2 MHzQ 4 MHz
N normal temperature rangeE extended temperature range
NN not explosion-proofA2 ATEX zone 2/IECEx zone 2A1 ATEX zone 1/IECEx zone 1F2 FM Class I Div. 2
TS direct connection or connection via junction boxXXX 0 m: without extension cable
> 0 m: with extension cableLC long transducer cableOS housing with stainless steel 316
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus12
Technical data
Shear wave transducers (zone 2 - FM Class I Div. 2 - nonEx, TS)
order code GSG-N**TS/** GSK-N**TS/** GSM-N**TS/** GSP-N**TS/** GSQ-N**TS/**technical type G(DL)G1N52 G(DL)K1N52 G(DL)M2N52 G(DL)P2N52 G(DL)Q2N52transducer frequency MHz 0.2 0.5 1 2 4inner pipe diameter dmin. extended inch 7.1 2.8 1.5 0.71 0.35min. recommended inch 9.4 3.9 1.9 0.94 0.47max. recommended inch 36.2 14.6 7.1 3.5 1.8max. extended inch 51.2 20.5 10.2 5.1 2.6pipe wall thicknessmin. inch 0.44 0.17 0.09 0.04 0.02materialhousing PEEK with stainless steel cover 304, ***-*****/OS: 316Lcontact surface PEEKdegree of protection NEMA 6transducer cabletype 1699length ft 16 13 9length (***-*****/LC) ft 29dimensionslength l inch 5.1 4.98 2.52 1.57width b inch 2.01 2.01 1.26 0.87height h inch 2.64 2.66 1.59 1dimensional drawing
weight (without cable)
lb 1 0.79 0.15 0.04
pipe surface temperaturemin. °F -40max. °F +266ambient temperaturemin. °F -40max. °F +266temperature com-pensation
x
explosion protection• ATEX/IECExorder code GSG-NA2TS/** GSK-NA2TS/** GSM-NA2TS/** GSP-NA2TS/** GSQ-NA2TS/**pipe surface temperature (Ex)• min. °C -55• max. °C gas: +190, dust: +180marking
Ex nA IIC T6...T3 GcEx tb IIIC T80 °C...T185 °C Db
certification ATEX IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X• FMorder code GSG-NF2TS/** GSK-NF2TS/** GSM-NF2TS/** GSP-NF2TS/** GSQ-NF2TS/**pipe surface temperature (Ex)• min. °F -40• max. °F +257 +374degree of protection IP66marking NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/Temp. Codes dwg 3860
l
hb
l
hb
l
hb
l
hb
II3GII2D0637
Technical specification FLUXUS G722ST-HT
13TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Shear wave transducers (zone 2 - FM Class I Div. 2 - nonEx, TS, extended temperature range)
order code GSG-ENNTS/** GSK-ENNTS/** GSM-E**TS/** GSP-E**TS/** GSQ-E**TS/**technical type G(DL)G1E52 G(DL)K1E52 G(DL)M2E52 G(DL)P2E52 G(DL)Q2E52transducer frequency MHz 0.2 0.5 1 2 4inner pipe diameter dmin. extended inch 5.9 2.4 1.3 0.63 0.31min. recommended inch 7.9 3.1 1.6 0.79 0.39max. recommended inch 35.4 14.2 7.1 3.5 1.8max. extended inch 51.2 20.5 10.2 5.1 2.6pipe wall thicknessmin. inch 0.44 0.17 0.09 0.04 0.02materialhousing PPSU with stainless steel cover 304
, ***-*****/OS: 316L PI with stainless steel cover 304, ***-*****/OS: 316L
contact surface PPSU PIdegree of protection IP65 NEMA 4transducer cabletype 1699 6111length ft 16 13 9length (***-*****/LC) ft 29 29dimensionslength l inch 5.1 2.52 1.57width b inch 2.01 1.26 0.87height h inch 2.64 1.59 1dimensional drawing
weight (without cable)
lb 1.8 0.15 0.04
pipe surface temperaturemin. °F 212 212 212max. °F 338 4501 392ambient temperaturemin. °F -40 -22 -22max. °F +338 +104
+1402
+3923
+392
temperature com-pensation
x x
explosion protection• ATEX/IECExorder code - - GSM-EA2TS/** GSP-EA2TS/** GSQ-EA2TS/**pipe surface temperature (Ex)• min. °C - - -45• max. °C - - gas: +2351, dust: +2251
marking - -
Ex nA IIC T6...T2 GcEx tb IIIA T80 °C...230 °C Db
certification ATEX - - IBExU10ATEX1163 Xcertification IECEx - - IECEx IBE 12.0005X• FMorder code - - GSM-EF2TS/** GSP-EF2TS/** GSQ-EF2TS/**pipe surface temperature (Ex)• min. °F - - -40• max. °F - - +4551
degree of protection - - IP66marking - - NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/Temp. Codes dwg 3860
1 > +200 °C/+392 °F:PermaLok without cover; quick release clasps and tension straps (nonEx)observe the insulation instructionEx: ambient temperature max. +40 °C/+104 °F
2 pipe surface temperature +200 to +232 °C/+392 to +450 °F: quick release clasps and tension straps3 pipe surface temperature max. +200 °C/+392 °F
l
bh
l
hb
l
hb
II3GII2D0637
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus14
Shear wave transducers (zone 1, TS)
order code GSG-N*1TS/** GSK-N*1TS/** GSM-N*1TS/** GSP-N*1TS/** GSQ-N*1TS/**technical type G(DL)G1N81 G(DL)K1N81 G(DL)M2N81 G(DL)P2N81 G(DL)Q2N81transducer frequency MHz 0.2 0.5 1 2 4inner pipe diameter dmin. extended inch 7.1 2.8 1.5 0.71 0.35min. recommended inch 9.4 3.9 1.9 0.94 0.47max. recommended inch 36.2 14.6 7.1 3.5 1.8max. extended inch 51.2 20.5 10.2 5.1 2.6pipe wall thicknessmin. inch 0.44 0.17 0.09 0.04 0.02materialhousing PEEK with stainless steel cover 304 , ***-*****/OS: 316L contact surface PEEKdegree of protection IP65 IP66 IP65transducer cabletype 1699length ft 16 13 9length (***-*****/LC) ft 29dimensionslength l inch 5.1 4.98 2.52 1.57width b inch 2.01 2.01 1.26 0.87height h inch 2.64 2.66 1.59 1dimensional drawing
weight (without cable)
lb 1 0.79 0.15 0.04
pipe surface temperaturemin. °F -40max. °F +266ambient temperaturemin. °F -40max. °F +266temperature com-pensation
x
explosion protection• ATEX/IECExorder code GSG-NA1TS/** GSK-NA1TS/** GSM-NA1TS/** GSP-NA1TS/** GSQ-NA1TS/**pipe surface temperature (Ex)• min. °C -55• max. °C +180marking
Ex q IIC T6...T3 GbEx tb IIIC T80 °C...T185 °C Db
certification ATEX IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X
l
bh
l
bh
l
bh
l
bh
0637 II2GII2D
Technical specification FLUXUS G722ST-HT
15TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Shear wave transducers (zone 1, TS, extended temperature range)
order code GSG-E*1TS/** GSK-E*1TS/**technical type G(DL)G1E83 G(DL)K1E83transducer frequency MHz 0.2 0.5inner pipe diameter dmin. extended inch 5.9 2.4min. recommended inch 7.9 3.1max. recommended inch 35.4 14.2max. extended inch 51.2 20.5pipe wall thicknessmin. inch 0.44 0.17materialhousing PPSU with stainless steel cover 304
, ***-*****/OS: 316L contact surface PPSUdegree of protection IP65transducer cabletype 1699length ft 16length (***-*****/LC) ft 29dimensionslength l inch 5.1width b inch 2.01height h inch 2.64dimensional drawing
weight (without cable)
lb 1.8
pipe surface temperaturemin. °F 212max. °F 338ambient temperaturemin. °F -40max. °F +338temperature com-pensation
x
explosion protection• ATEX/IECExorder code GSG-EA1TS/** GSK-EA1TS/**pipe surface temperature (Ex)• min. °C -50• max. °C +140marking
Ex q IIC T6...T3 GbEx tb IIIC T80 °C...T145 °C Db
certification ATEX IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X
l
bh
II2GII2D0637
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus16
Shear wave transducers (zone 1, TS, extended temperature range)
order code GSM-E*1TS/** GSP-E*1TS/** GSQ-E*1TS/**technical type G(DL)M2E85 G(DL)P2E85 G(DL)Q2E85transducer frequency MHz 1 2 4inner pipe diameter dmin. extended inch 1.3 0.63 0.31min. recommended inch 1.6 0.79 0.39max. recommended inch 7.1 3.5 1.8max. extended inch 10.2 5.1 2.6pipe wall thicknessmin. inch 0.09 0.04 0.02materialhousing PI with stainless steel cover 304, ***-*****/OS: 316Lcontact surface PIdegree of protection IP66 IP56transducer cabletype 6111length ft 13 9length (***-*****/LC) ft 29dimensionslength l inch 2.52 1.57width b inch 1.26 0.87height h inch 1.59 1dimensional drawing
weight (without cable)
lb 0.15 0.04
pipe surface temperaturemin. °F 212 212max. °F 4501 392ambient temperaturemin. °F -22 -22max. °F +104
+3922+392
temperature com-pensation
x
explosion protection• ATEX/IECExorder code GSM-EA1TS/** GSP-EA1TS/** GSQ-EA1TS/**pipe surface temperature (Ex)• min. °C -45• max. °C +2251
marking
Ex q IIC T6...T2 GbEx tb IIIA T80 °C...T230 °C Db
certification ATEX IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X1 > +200 °C/+392 °F:
PermaLokobserve the insulation instructionambient temperature max. +40 °C/+104 °F
2 pipe surface temperature max. +200 °C/+392 °F
l
hb
l
hb
II2GII2D0637
Technical specification FLUXUS G722ST-HT
17TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Transducer mounting fixture
Order code
1, 2 3 4 5 6 7 to 9 no. of charactertr
ansd
uce
r m
ou
nti
ng
fi
xtu
re
tra
ns
du
cer
- me
as
ure
me
nt
arr
an
ge
men
t
siz
e
- fix
ati
on
ou
ter
pip
e d
iam
eter
/ op
tio
n
de
scr
ipti
on
PL PermaLokWI transducer box for WaveInjector
K transducers with transducer frequency G, KM transducers with transducer frequency M, PQ transducers with transducer frequency Q
D diagonal arrangement/direct modeS smallL large
S tension strapsSK1 0.5 to 2.5 inchSK2 3 to 6 inch
SK3 8 to 10 inch
SK4 12 to 18 inch
SK5 20 to 36 inch
SK6 42 to 100 inch
IP68 for transducers with degree of protection IP68OS housing with stainless steel 316Z special design
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus18
PermaLok PL
material: stainless steel 316
quick release clasps and tension straps
material: stainless steel 410, 200
transducer box WI for WaveInjector
see Technical specificationTSWaveInjectorVx-x
transducer box
Technical specification FLUXUS G722ST-HT
19TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Coupling materials for transducers
type ambient temperature remark
°Fcoupling pad type VT 14 to +392 fluid temperature 392 °F: min. 2 years
coupling pad type TF 392 to 464
coupling compound type E -22 to +392 in combination with type VT only
coupling compound type H -22 to +482 in combination with type TF only
coupling pad type A max. 536 WaveInjector
coupling pad type B 536 to 752 WaveInjector
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus20
Connection systems
Cable
connection system TS
connection with extension cable direct connection transducerstechnical type*****8*
*****52
transducer cable
type 1699 6111weight lb/ft 0.06 0.06ambient temperature °F -67 to +392 -148 to +437propertiescable jacketmaterial PTFE PFAouter diameter inch 0.11 0.11thickness inch 0.01 0.02color brown whiteshield x xsheathmaterial stainless steel 304 stainless steel 304
option OS: 316Ti option OS: 316Tiouter diameter inch 0.31 0.31
extension cable
type 2615 5245weight lb/ft 0.12 0.26ambient temperature °F -22 to +158 -22 to +158properties halogen free
fire propagation test according to IEC 60332-1
combustion test according to IEC 60754-2
halogen free
fire propagation test according to IEC 60332-1
combustion test according to IEC 60754-2
cable jacketmaterial PUR PURouter diameter inch max. 0.47 max. 0.47thickness inch 0.08 0.08color black blackshield x xsheathmaterial - steel wire braid with copolymer
sheathouter diameter inch - max. 0.61
tra
nsm
itte
r
JB01 x
l
tra
nsm
itte
r
x
tra
nsm
itter
JB02, JB03, JB04x
l
tran
smitt
er
x
Technical specification FLUXUS G722ST-HT
21TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Cable length
transducer frequency
F, G, H, K M, P Q S
connection system TStransducerstechnical type
x l x l x l x l
*(DR)***8* ft 16 ≤ 984 13 ≤ 984 9 ≤ 295 - -option LC:*(LT)***8*
ft 29 ≤ 984 29 ≤ 984 29 ≤ 295 - -
*(DR)***5* ft 16 ≤ 984 13 ≤ 984 9 ≤ 295 6 ≤ 131option LC:*(LT)***5*
ft 29 ≤ 984 29 ≤ 984 29 ≤ 295 - -
x = transducer cable length
l = max. length of extension cable (depending on the application)
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus22
Junction box
Technical data
JB01S4E3M, JBP2, JBP3
weight lb 2.6 lbfixation wall mounting
optional: 2" pipe mountingmaterialhousing stainless steel 316Lgasket siliconedegree of protection NEMA 6ambient temperaturemin. °F -40max. °F +176explosion protection• ATEX/IECEx (zone 1)junction box JB01S4E3Mmarking
Ex eb mb IIC T6...T4 GbEx tb IIIC T100 °C DbTa -40...+70/80 °C
certification ATEX IBExU06ATEX1161certification IECEx IECEx IBE 08.0006type of protection gas: increased safety
decoupled network: encapsula-tion
dust: protection by enclosure• ATEX (zone 2)junction box JBP2marking
II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C
JB02, JB03, JB04
weight lb 2.6 lbfixation wall mounting
optional: 2" pipe mountingmaterialhousing stainless steel 316Lgasket siliconedegree of protection IP67ambient temperaturemin. °F -40max. °F +176explosion protection• ATEXjunction box JB02marking
II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C
• FMjunction box JB04marking NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/T6 Ta = -40...+60 °C
Connection
Transducers
Extension cable
terminal strip terminal connection transducer
KL1 V signalVS internal shieldRS internal shieldR signal
terminal strip terminal connection
KL2 TV signalTVS internal shieldTRS internal shieldTR signal
II2GII2D0637
Connection
Transducers
Extension cable
terminal connection transducer
XV SMB connector
XR SMB connector
terminal strip terminal connection
KL2 TV signalTVS internal shieldTRS internal shieldTR signal
Technical specification FLUXUS G722ST-HT
23TSFLUXUS_G722ST-HTV1-0US_Lus, 2020-10-01
Dimensions
2" pipe mounting kit
JB0*, JBP*
JB**
order code:ACC-PE-GNNN-/JBPMK4
6.85
4.69
0.08
wall mounting holder
2.76
6.44
6.1
4Ø 0.35
thread: 3x M20 x 1.5cable gland: max. 2x 1/2 NPT
in inch
FLUXUS G722ST-HT Technical specification
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus24
Clamp-on temperature probe (optional)
Technical data
Fixation
Junction box
PT13N
design clamp-ontype Pt1000connection 4-wiremeasuring range °F -40 to +392accuracy T ±(0.27 °F + 2 . 10-3 . (|T [°F]| -
32 °F))class A
accuracy ∆T(2x Pt matched according to EN 1434-1)
≤ 0.03 °F (at 50 °F)
housing 360 brass alloydegree of protection NEMA 4dimensions
length l inch 0.79width b inch 0.59height h inch 0.49dimensional drawing
weight lb 0.437accessories
thermal conductivity foil 482 °F
x
tension strap PT13N
material: stainless steel 301, 410
thermal insulation necessary
Connection system
Connection
Cable
connection with extension cable direct connection
temperature probe
red
red
white
white
temperature probe extension cable
type 4 x 24 AWG 4 x 18 AWGstandard length ft 20 -max. length ft - 656cable jacket PTFE LS PVC
junction box
extension cable
h
lb
4.72”
½” NPT
1.34"
1.18”1.18”
Top View
Side View
Connection
temperature probe extension cable
red whitered blackwhite greenwhite red
FLEXIM AMERICAS CorporationEdgewood, NY 11717
USA
Tel.:(631) 492-2300Fax:(631) 492-2117
internet: www.flexim.come-mail: [email protected]
1-888-852-7473
Subject to change without prior notice.Errors excepted.
FLUXUS is a registered trademark of FLEXIM GmbH.
Copyright (©) FLEXIM GmbH 2020
2020-10-01, TSFLUXUS_G722ST-HTV1-0US_Lus