7
T8 TYPE A+B GLASS TUBE Aluminum Cap & Plastic Cap Shatter-proof Coating Optional VIRTUTECH LED TUBE

T8 TYPE A+B GLASS TUBE

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: T8 TYPE A+B GLASS TUBE

T 8 T Y P E A + B G L A S S T U B E

Aluminum Cap & Plastic Cap

Shatter-proof Coating Optional

VIRTUTECH

LED TUBE

Page 2: T8 TYPE A+B GLASS TUBE

Wattage Length (ft)

CCT(Kelvin)

Luminous flux (lm)

CRI(Ra)

Pack Qty (Pcs)

ItemNumber

Beam Angle Dimming(W) (Degree)

* All data are related to the entire product

For technical information of other CCT, please contact our sales representative.

Due to the special conditions of the manufacturing processes of LED,the typical data of technical parameters can only reflect statistical figures anddo not necessarily correspond to the actual parameters of each single product which could differ from the typical value.

LED Tube T8 High Output

3000 / 4000 / 5000... G13 50,000 H

220°

BEAM ANGLE

T8 LED Tube For Car Parks

*

G=Glass

Version

SYHU

It can be A ,B,C,D

Model Instructions

Company Code Category

T8 =T8 Tube

Materia

AB=Type A+B

DLC Type Length

06=60cm=2ft12=120cm=4ft

Wattage

10=10W12=12W

15=15W18=18W

DiffuserCap Material

XXT8 G AB 06/12 10/12/15/18

T =Transparent“M”=Milky

A =AluminumP=Plastic

CCT

YY30=3000K35=3500K40=4000K45=4500K50=5000K.......

Z

Electrical and Photometric Characteristics*

S Y H U - T 8 G A B B E U L 0 6 1 0 X X - Y Y - Z

VER#:V2.1Revised: 2020-08-17

12 4 >80

15 4 >80

18 4 >80

25

25

25

> 220°

> 220°

> 220°

NO

NO

NO

10 2 3000/3500/4000/4500/50003000/3500/4000/4500/50003000/3500/4000/4500/50003000/3500/4000/4500/50003000/3500/4000/4500/5000

>80 25> 220° NO

SYHU-T8GABBEUL1212XX-YY-Z

SYHU-T8GABBEUL1218XX-YY-Z

SYHU-T8GABBEUL1215XX-YY-Z

SYHU-T8GABBEUL0610XX-YY-Z

Rate Wattage Luminous (lm)

12 12.515 15.818 18.9 2312

ItemNumber

SYHU-T8GABBEUL1212XX-YY-Z

SYHU-T8GABBEUL1218XX-YY-ZSYHU-T8GABBEUL1215XX-YY-Z

(W)10 10.6 1392SYHU-T8GABBEUL0610XX-YY-Z

Ballast Factor(W) 0.78

Ballast Factor(W) 0.88

Ballast Factor(W) 1.1

14.818.2221.28

12.31

16.519.522.1

14.210 10.6

173520882312

13921623

17352088

1623SYHU-T8GABBEUL1210XX-YY-Z 12.31 14.2

IP RatingIP20

Power Factor>0.9

Starting Time<1.0 s

Base TypeG13

Operating Temp.-20°C ~ +45°C

Non-dimmable

Lumen Maintenance50,000Hours

CRI>80

10 4 >80 25> 220° NOSYHU-T8GABBEUL1210XX-YY-Z

Nominal Voltage120V-277V

BE=Both end

Power mode

BE

Certificate

UF=UL +FCC

UL=UL

UL/UF

VIRTUTECH

Phone: +86-752-5331203 Web: www.virtuled.com E-mail: [email protected] | |

Page 3: T8 TYPE A+B GLASS TUBE

Luminous Intensity Distribution Diagram

Maximum overall length (mm) 4ft

8911A

2ft

588B 1205595

C 1213603

Dimension Diagram*

*

T8 LED Tube For Supermarket

2D Light Intensity Distribution Curve

Polar Graph

C Plane: C0.0γ Cone: γ5.0

0

30

60

90

120

150

180

210

240

270

300

330

0.0

87.9

175.8

263.7

351.6

439.5

Plane [50%Ang.] [10%Ang.]

C0.0: 209.5 343.1

4ft 5000K 18W 2100LM

)m(retemaiD)xl(E retneC)m(thgieH

1.0 434.40 -7.594

2.0 108.60 -15.188

3.0 48.27 -22.782

Beam Angle:209.5

CBA

VIRTUTECH

Phone: +86-752-5331203 Web: www.virtuled.com E-mail: [email protected] | |

Page 4: T8 TYPE A+B GLASS TUBE

T8 LED Tube For Industry

Package *

Size

2ft4ft

Qty/Carton

2525

Qty/Pallet

12502500

Container Container(with pallet)20’GP 40’GP 40’HQ 45’HQ

1140023325

20’GP 40’GP 40’HQ 45’HQ

2425049125

3187563875

3977579775

1000020000

2250045000

2287545750

2750055000

Size

2ft4ft

Net Weight/Pcs Gross Weight/CartonSize of CartonLxWxH (mm/in)

625x 195 x 195mm / 24.6”x 7.7”x 7.7”1235 x 195 x 195mm / 48.62”x 7.7”x 7.7”

0.11kg/0.24lbs0.19kg/0.42Ibs

3.3kg/7.26lbs5.64kg/12.43lbs

2ft 4ft100 Cartons 50 Cartons

20

00

mm

1 0 5 0 m m

1 2 6 0 mm

21

27

mm

* Note: The above full container load quantities are based on tube packages foam holders+outer carton.

(* This data Based on the 40’GP)

Package Dimension

Package Information

Pallet Packing Information

≈≈

≈≈

≈≈

≈≈

≈≈

≈≈

≈≈

≈≈

≈≈

VIRTUTECH

Phone: +86-752-5331203 Web: www.virtuled.com E-mail: [email protected] | |

Page 5: T8 TYPE A+B GLASS TUBE

Installation Diagram*

Installation Guide:

1. Turn off the power2. Remove diffuser ( if provided).

(if provided).

1. Turn off the power2. Remove diffuser ( if provided).

Remove the fluorescent tubes. Please dispose of these items properly as they contain mercury.Put led tube in the lig ng fixture.Install the led tubes, close the diffuserTurn on the power.

3.4.5.6.

“Plug” and “Play” procedure

Retrofit Procedure

WARNING

Remove the fluorescent tubes. Please dispose of these items properly as they contain mercury.Cut the wires as shown in the diagram.Make the new wire connect to branch circuit as shown. Replace the cover over the wiring chanel. Install the led tubes, close the diffuser.Turn on the power.

3.4.5.6.7.8.

(UL TypeA)

E479498LISTED

suitable for wet loca on.Direct replacement for 32W*48T8(4 ) fluorescent G13 base lamps.

*

IF US

ING

SINGL

E END

ED

E479498LISTED

suitable for wet loca on.Direct replacement for 32W*48T8(4 ) fluorescent G13 base lamps.

*

IF US

ING

SINGL

E END

EDE479498LISTED

suitable for wet loca on.Direct replacemen or 32W*48T8 (4 ) fluorescent G13 base lamps.

*

IF US

ING

SINGL

E END

ED

E479498LISTED

suitable for wet loca on.Direct replacement for 32W*48T8(4 ) fluorescent G13 base lamps.

*

IF US

ING

SINGL

E END

ED

Before After

1. These lamps should be installed by a licensed electrician.2. These lamps should be used indoors(damp or dry locations only).Not suitable for wet location.3. Make sure tombstones/lampholder are still in good condition and not defected before installation.4. Ensure the brand and model no. of the ballast of replacement tube are in our compatible ballast list.5. Make sure the ballast is working and still under warranty before installation.6. Put LED tubes/G13 pins into right position of the socket, install properly.7. This device is not suitable for using with emergency exits.8. These lamps are not suitable to be used with a light dimmer.If the LED lamp damaged by any one you didn’t comply with above warning. We’ll not responsible for that.

Before

(UL TypeB)

E479498LISTED

suitable for wet loca on.Direct replacemen or 32W*48T8(4 ) fluorescent G13 base lamps.

*

IFU

SIN

GSI

NGL

E EN

DED

C O

E479498LISTED

suitable for wet loca on.Direct replacemen or 32W*48T8(4 ) fluorescent G13 base lamps.

*

IFU

SIN

GSI

NGL

E EN

DED

CO

E479498LISTED

suitable for wet loca on.Direct replacemen or 32W*48T8(4 ) fluorescent G13 base lamps.

*

IFU

SIN

GSI

NGL

E EN

DED

CO

Single End Double End

BeforeE479498LISTED

suitable for wet loca on.Direct replacemen or 32W*48T8(4 ) fluorescent G13 base lamps.

*

IFU

SIN

GSI

NGL

E EN

DED

CO

VIRTUTECH

Phone: +86-752-5331203 Web: www.virtuled.com E-mail: [email protected] | |

Page 6: T8 TYPE A+B GLASS TUBE

Ballast List For T8 LED Tube*

ACCUPROAP-432IP-UNV

ADVANCEIOPA-4P32-LW-N

ESPENVE232MVHIPLEVE232MVHIPEVE432MVHIPEVE432MVHIPLEVE432120HIP

GEGE232MAX-L/Ultra

HalcoEP232IS/L/MV/HE

HOWARD INDUSTRIESEP3/32IS/MV/MC/HE

Pacific FluorescentEB-232IS-120-RES

GE332MAX-N/Ultra

KEYSTONEKTEB-232RIS-1-TP-SLKTEB-232RIS-1-TP-SL/Ga

GE232MAX347-N

OSRAMQHE 2x32T8/UNV ISN-SCQHE 3x32T8/UNV ISN-SCQHE 3x32T8/UNV PSN-SC

GE432MAX347-NGE232-MVPS-NGE332-MVPS-NGE432-MVPS-NGE432-120RESDIYB

PHILIPSICN-2P32-NICN-3P32-NICN-2S40-NIOP-4P32-LW-NIOPA-1P32-NIOPA-4P32-NIOPA-2P32-LW-N

SYLVANIAQHE 1x32T8/UNV ISN-SCQHE 3x32T8/UNV ISL-SCQTP 2x32T8/UNV ISL-SCQT 4X32/120 LP

TRIADB232IUNVHP-NB332IUNVHP-AB432IUNVHP-AB232IUNVHP-B

QT 2x32 T8/347 ISL-SCQHE 4x32T8/347 ISN-SCQHE 4x32T8/347 ISL-SC

UNIVERSALB332IUNVHE-AB432IUNVHE-A

WORK HORSEWH3-120-CWH3-120-L

B232IUNVEL-NB332IUNVEL-AB232IUNVHEH-AB332PUNVHE-AB4321UNVEL-A

IOP-3P32-N

GE-240-RS-MV-NGE232-N-347GE132MAX-H/ULTRA

AP-332IP-UNV-M

VIRTUTECH

Phone: +86-752-5331203 Web: www.virtuled.com E-mail: [email protected] | |

Page 7: T8 TYPE A+B GLASS TUBE

© 2020 Virtutech rights reserved. This document contains information relating to Virtutech product portfolio. Note that the information provided is subject to change. Virtutech does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. Virtutech or their respective owners.