SYSMAC OPC Server
Data sheet
About SYSMAC OPC Server
The SYSMAC OPC Server is an app l ica t ion
des igned to opera te wi th Microsof t Windows2000/NT/98/95 as an OPC loca l / remote
server fo r OPC Data Access2.0 . And i t i sdes igned fo r use wi th the OMRON SYSMAC
C/CV/CS1 ser ies . OPC Server p rov idesSYSMAC communica t ion serv ice to OPCClient sof tware ( for example WonderwareInTouch, In te l lu t ion iF ix ,Rockwel l RS-View e tc ) .
A lso i t suppor ts OPC Automat ion in ter face touse f rom Microsof t V isua l Bas ic and
Excel(VBA).
Controller Link
Windows95/98/NT4.0
Ethernet
SYSMAC LINK
SYSMAC-C/CV/CS1
RS232C
OLEAutomation
Interface
SYSMACOPC Server
(SysmacExplorer)
OPC ClientVisualBASIC
EXCEL(VBA)
Custom I/F
OPC Client
DCOM
SYSMAC-C/CV/CS1 SYSMAC-C/CV/CS1
• ¡Feature and FunctionØ SYSMAC communication based FinsGatew ay
SYSMAC LINK
CONTROLLER LINK
ETHERNET
Serial Link
SYSMAC BOARD
SYSMAC NET
Ø SYSMAC C/CV/CS1 series support
Ø Free threading serverØ OPC Automation interface support
Ø Tag data import/export
Ø Au tomatic Tag reg is tr y
Ø Data Type
Boolean/WORD/Double WORD/REAL/STRING
Ø Scale convert
Ø Simulationmode
(RAMP/SIN/RANDOM/DUMMY)
Ø Tag monitorØ Communication log
System Requirement
PC system requirement
PC running Windows 2000 /NT/98/95.
A 200 MH z Pentium CPU or be tt er .
(Inte l brand CPU is required)
64 MB RAM total
Required Hard Drive Space:10 MB or more
Operating system
Windows2000/NT4.0 or Windows95/98
(For Windows 98/95, DCOM for Windows 98/95 is needed)
PLC System• ¡CPU System
FinsGateway compatible PLC system
(SYSMAC C/CV/CS1)
CommunicationsSYSMAC LINK
Ø Requires an OMRON SYSMAC LINK Support
Board (i.e., 3G8F5-SLK21)
Ø Only one SYSMAC LINK Support Board can be
installed in one computer.
Ø The software included with the Board cannot be
used with FinsGateway.
Ø The network gateway function cannot run.Controller Link
Ø Requires an OMRON Controller Link Support
Board (i.e., 3G8F5-CLK21)
Ø Only one Controller Link Support Board can be
installed in one computer.
Ø The software included with the Board cannot be
used with FinsGateway.
Ethernet
Ø Requires an Ethernet board which can be used
with WindowsNT or Windows95.
Ø TCP/IP must be installed. FINS communications
on the Ethernet use UDP/IP. TCP/IP is included inWindowsNT.
Ø Has a fixed IP address allocated.
Ø Cannot be used on a system with DHCP
configuration, because the Ethernet unit requires
a static IP address.
Serial Link
Ø A PC 95-compliant COM port which can be used
with WindowsNT or Windows95.
Ø The above COM port must be used exclusively by
FinsGateway. Other applications not using
FinsGateway cannot use the COM port
simultaneously.
Ø COM ports that can be specified by the serial
communications of FinsGateway are COM1 to
8/9/2019 Sysmacdatasheet Us
http://slidepdf.com/reader/full/sysmacdatasheet-us 2/4
-2-
SYSMAC OPC Server
Data sheet
COM4.
SYSMAC BoardØ OMRON SYSMAC Board (C200PC-ISA-01-DRM)
Ø The software included with the board cannot be
used with FinsGateway.
Ø Requires an OMRON SYSMAC NET Support
Board (i.e., 3G8F5-SNT31)
Ø Only for WindowsNT. Windows95 edition is
unavailable.
Ø The software included with the board cannot be
used with FinsGateway.
Ø Data link is not supported.
Ø Either binary code or ASCII code can be selected
as the send/receive code.
Ø Either FINS mode or C-mode can be selected as
the datagram format. If C-mode is selected, some
FINS commands are automatically changed to
those of the C-mode.
MEMO
Supported Device and Access Range
Protocol and Access Range
C series
Chann el Variable name Range
R Relay area 0• `255
HR Keeping relay 0• `99
AR Sub-memory re lay 0• `27
LR Link relay 0• `63
DM Data memory 0• `9999
EMExpansion data
memory0• `9999
CV series
Chann el Variable name Range
R Relay area 0• `2555
AR Sub-memory re lay 0• `51 1
DM Data memory 0• `24575
EMExpansion data
memory0• `32765
CS1 series
Chann el Variable name Range
R Relay area 0• `6143
HR Keeping relay 0• `511
AR Sub-memory re lay 0• `95 9
WR Inner sub relay 0• `511
DM Data memory 0• `32767
EMExpansion data
memory0• `32767
* Variable range is defined by each PC. Referto the user’s manual of your using CPU.
* C/CV series you are unable to write in by Bit.
Tag registration does not check the range.You should set the range adapted to the PLC
system you use.
8/9/2019 Sysmacdatasheet Us
http://slidepdf.com/reader/full/sysmacdatasheet-us 3/4
-3-
SYSMAC OPC Server
Data sheet
OPC Custom interfaceData type
VT_BOOL Boolean
VT_I2 Word
VT_I4 Double word
VT_R4 Real
VT_BSTR String
OPC interfaceOPCServer Object
IOPCCommonMember Support
SetLocaleID Active
GetLocaleID Active
QueryAvailableLocalIDs Active
GetErrorString Active
SetClientName Active
IOPCServerMember Support
AddGroup Active
GetErrorString Active
GetGroupByName Active
GetStatus Active
RemoveGroup Active
CreateGroupEnumerator Active
IOPCServerPublicGroups (Option)
Member Support
GetPublicGroupByName Inactive
RemovePublicGroup Inactive
IOPCBrowseServerAddressSpace (Option)
Member Support
QueryOrganization Active
(OPC_NS_HIERARCHIAL willbe return)
ChangeBrowsePosition Active
BrowseOPCItemIDs Active
GetItemID Active
BrowseAccessPaths Inactive (
E_NOTIMPwill be return)
IPersistFile (Option)
Member SupportIsDirty Inactive
Load Inactive
Save Inactive
SaveCompleted Inactive
GetCurFile Inactive
IOPCItemPropertiesMember Support
QueryAvailableProperties Active
GetItemProperties Active
LookutItemIDs Active
IConnectionPointContainerMember Support
EnumConnectionPoints Active
FindConnectionPoints Active
OPCGroup Object
IOPCGroupStateMgtMember Support
GetState Active
SetState ActiveSetName Active
CloneGroup Active
IOPCPublicGroupStateMgtMember Support
GetState Inactive
MoveToPublic Inactive
IOPCSyncIOMember Support
Read ActiveWrite Active
IOPCAsyncIO (Old)Member Support
Read Active
Write Active
Refresh Active
Cancel Inactive (E_NOTIMP willbe return)
8/9/2019 Sysmacdatasheet Us
http://slidepdf.com/reader/full/sysmacdatasheet-us 4/4
-4-
SYSMAC OPC Server
Data sheet
IOPCItemMgt
Member Support AddItems Active
ValidateItems Active
RemoveItems Active
SetActiveState Active
SetClientHandles Active
SetDatatypes Active
CreateEnumerator Active
IDataObject (Old)Member Support
DAdvise Active
DUnadvise Active
IOPCASyncIO2Member Support
Read Active
Write ActiveRefresh Active
Cancel2 Active
SetEnable Active
GetEnable Active
IConnectionPointContainer
Member SupportEnumConnectionPoints Active
FindConnectionPoint Active
OPC Enum ObjectIEnumOPCItemAttributes
Member Support
Next Active
Skip Active
Reset Active
Clone Active
OPC Automation interface support
OPC Automation interface wrap OPC Custom
interface. Generally, It provides same function with
OPC Custom interface. You can download OPC
Automation in terface sp ecif icat ions from fo llowing
OPC Foundation web site.
URL http://www.opcfoundation.org/
ContactTakebishi Electric Sales Corporation29 Mamedacho Nishikyougoku Ukyo-ku Kyoto
Japan 615-8501Phone +81(75)325-2171 FAX +81(75)325-2273Email [email protected]
URL http://www.faweb.net
OPC Data Access
Automation interface
OPC Data AccessCustom
interface
Visual C++
Visual BasicVBA(Excel,
Access)