9
CONTAINING COMPONENTS MADE OR SOLD BY MAZZEI. TITLE: SIZE: JOB NO.: DRAWING NUMBER: REV: SCALE: WEIGHT: WITHOUT THE WRITTEN PERMISSION OF 1 PL WWW.MAZZEI.NET MAZZEI INJECTOR CO., LLC INJECTOR; MODEL SSC2081-M B NA SSC02081MBB00-SUB NC NONE 1 OF 2 T. JOHNS APPROVALS DATE DRAWN: 4/12/2013 J. MILLAN P. BANKOWSKI - CHECKED: APPROVED: QA: CUSTOMER: 4/12/2013 4/12/2013 .1/2 PHONE: (661) 363-6500 FAX: (661)363-7500 DO NOT SCALE NA SHEET: SUBMITTAL NOTICE .060 3 PL - 500 ROOSTER DRIVE BAKERSFIELD, CA 93307 CUSTOMER APPROVAL: .125 2 PL MAZZEI IS STRICTLY PROHIBITED. CONFIDENTIALITY NOTICE INTERPRET DIM AND TOL PER .030 REPRODUCTION IN PART OR AS A WHOLE ASME Y14.5M-1994 MAZZEI INJECTOR COMPANY LLC. ANY DRAWING IS THE SOLE PROPERTY OF THIRD ANGLE PROJECTION THE INFORMATION CONTAINED IN THIS DRAWING MAY NOT BE PRINTED FULL SIZE UNLESS OTHERWISE SPECIFIED DIM ARE IN INCHES TOL ON ANGLE ANY RECOMMENDATIONS FOR PRODUCT AND/OR SYSTEM DESIGN, WHETHER CONTAINED IN A DOCUMENT, WITHIN THIS DRAWING, COMMUNICATED BY ELECTRONIC MEANS OR GIVEN VERBALLY, ARE INTENDED SOLELY AS GUIDELINES TO ACTUAL SYSTEM DESIGN. SAID RECOMMENDATIONS ARE BASED UPON INFORMATION SUPPLIED BY OTHERS, THE ACCURACY OF WHICH IS BEYOND VERIFICATION BY MAZZEI INJECTOR CO. LLC. THEREFOR MAZZEI CANNOT AND DOES NOT WARRANT THE SUITABILITY OF ITS PRODUCTS FOR A PARTICULAR SERVICE NOR THE PERFORMANCE OF ANY SYSTEM 6 LBS APPLICATIONS". INSTALLATION RECOMMENDATIONS FOR GAS TO LIQUID MIXING 10. MAZZEI RECOMMENDS INSTALLING THE INJECTOR IN A HORIZONTAL SUBMITTAL DRAWING "MAZZEI INJECTOR MAZZEI TECHNICAL BULLETIN No. 11; APPLICATIONS THIS MAY AFFECT PERFORMANCE. PLEASE REFER TO WITH THE LIQUID FLOW UPWARDS. HOWEVER, IN CERTAIN POSITION. INJECTORS MAY BE INSTALLED IN A VERTICAL POSITION (ISOMETRIC VIEW) (FOR REFERENCE ONLY) NOTES: MATERIAL OF CONSTRUCTION: CD3MN STAINLESS STEEL 1. MTR/HEAT NUMBERS ARE PROVIDED "AS BUILT" AND SHALL MEET 2. APPLICABLE MATERIAL SPECIFICATIONS. INLET/OUTLET CONNECTION: 3. 2" DIA., SANITARY TRI-CLAMP FITTING MATERIAL: CD3MN SPECIFICATION: ASME BPE-2009 SUCTION PORT CONNECTION: 4. 1.50" DIA., SANITARY TRI-CLAMP FITTING MATERIAL: CD3MN SPECIFICATION: ASME BPE-2009 WELDING JOINTS TO BE COMPLETE JOINT PENETRATION, WHERE 5. POSSIBLE. DYE PENETRANT TESTING IN ACCORDANCE WITH ASME B31.3 6. NORMAL SERVICE RECOMMENDATIONS WILL BE PERFORMED ON A MINIMUM OF 20% OF LINEAR LENGTH OF WELDS; OR HYDROSTATIC TESTING WILL BE PERFORMED AS PART OF MAZZEI'S NON- DESTRUCTIVE TESTING PROCEDURE. CLEANED FOR PASSIVATION PER ASTM A380 GUIDELINES. 7. PASSIVATED PER ASTM A967 SPECIFICATION. 8. WELD MAP, NON DESTRUCTIVE TESTING (NDT), CLEANING AND 9. INSPECTION REPORTS TO BE PROVIDED BY MAZZEI. REVISIONS REV. DESCRIPTION DATE APPROVED NC RELEASED FOR SUBMITTAL. 4/12/2013 P. BANKOWSKI

SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

CONTAINING COMPONENTS MADE OR SOLD BY MAZZEI.

TITLE:

SIZE: JOB NO.: DRAWING NUMBER: REV:

SCALE: WEIGHT:

WITHOUT THE WRITTEN PERMISSION OF

1 PL WWW.MAZZEI.NET

MAZZEI INJECTOR CO., LLC

INJECTOR; MODEL SSC2081-M

B NA SSC02081MBB00-SUB NCNONE 1 OF 2

T. JOHNS

APPROVALS DATEDRAWN:

4/12/2013J. MILLAN

P. BANKOWSKI-

CHECKED:

APPROVED:

QA:

CUSTOMER:

4/12/20134/12/2013

.1/2 PHONE: (661) 363-6500 FAX: (661)363-7500

DO NOT SCALENA

SHEET:

SUBMITTAL NOTICE

.060 3 PL

-

500 ROOSTER DRIVE BAKERSFIELD, CA 93307

CUSTOMER APPROVAL:

.125 2 PL

MAZZEI IS STRICTLY PROHIBITED.

CONFIDENTIALITY NOTICE

INTERPRET DIM AND TOL PER .030

REPRODUCTION IN PART OR AS A WHOLE ASME Y14.5M-1994MAZZEI INJECTOR COMPANY LLC. ANY

DRAWING IS THE SOLE PROPERTY OF

THIRD ANGLE PROJECTION

THE INFORMATION CONTAINED IN THIS

DRAWING MAY NOT BE PRINTED FULL SIZE

UNLESS OTHERWISE SPECIFIEDDIM ARE IN INCHES

TOL ON ANGLE ANY RECOMMENDATIONS FOR PRODUCT AND/OR SYSTEM DESIGN, WHETHER CONTAINED IN A DOCUMENT, WITHIN THIS DRAWING, COMMUNICATED BY ELECTRONIC

MEANS OR GIVEN VERBALLY, ARE INTENDED SOLELY AS GUIDELINES TO ACTUAL SYSTEM DESIGN. SAID

RECOMMENDATIONS ARE BASED UPON INFORMATION SUPPLIED BY OTHERS, THE ACCURACY OF WHICH IS

BEYOND VERIFICATION BY MAZZEI INJECTOR CO. LLC. THEREFOR MAZZEI CANNOT AND DOES NOT WARRANT THE SUITABILITY OF ITS PRODUCTS FOR A PARTICULAR

SERVICE NOR THE PERFORMANCE OF ANY SYSTEM 6 LBS

APPLICATIONS".INSTALLATION RECOMMENDATIONS FOR GAS TO LIQUID MIXING

10. MAZZEI RECOMMENDS INSTALLING THE INJECTOR IN A HORIZONTAL

SUBMITTAL DRAWING

"MAZZEI INJECTOR MAZZEI TECHNICAL BULLETIN No. 11; APPLICATIONS THIS MAY AFFECT PERFORMANCE. PLEASE REFER TO WITH THE LIQUID FLOW UPWARDS. HOWEVER, IN CERTAIN POSITION. INJECTORS MAY BE INSTALLED IN A VERTICAL POSITION

(ISOMETRIC VIEW)(FOR REFERENCE ONLY)

NOTES:

MATERIAL OF CONSTRUCTION: CD3MN STAINLESS STEEL1.

MTR/HEAT NUMBERS ARE PROVIDED "AS BUILT" AND SHALL MEET 2.APPLICABLE MATERIAL SPECIFICATIONS.

INLET/OUTLET CONNECTION:3.2" DIA., SANITARY TRI-CLAMP FITTINGMATERIAL: CD3MNSPECIFICATION: ASME BPE-2009

SUCTION PORT CONNECTION:4.1.50" DIA., SANITARY TRI-CLAMP FITTINGMATERIAL: CD3MNSPECIFICATION: ASME BPE-2009

WELDING JOINTS TO BE COMPLETE JOINT PENETRATION, WHERE 5.POSSIBLE.

DYE PENETRANT TESTING IN ACCORDANCE WITH ASME B31.3 6.NORMAL SERVICE RECOMMENDATIONS WILL BE PERFORMED ON A MINIMUM OF 20% OF LINEAR LENGTH OF WELDS; OR HYDROSTATIC TESTING WILL BE PERFORMED AS PART OF MAZZEI'S NON-DESTRUCTIVE TESTING PROCEDURE.

CLEANED FOR PASSIVATION PER ASTM A380 GUIDELINES.7.

PASSIVATED PER ASTM A967 SPECIFICATION.8.

WELD MAP, NON DESTRUCTIVE TESTING (NDT), CLEANING AND 9.INSPECTION REPORTS TO BE PROVIDED BY MAZZEI.

REVISIONSREV. DESCRIPTION DATE APPROVEDNC RELEASED FOR SUBMITTAL. 4/12/2013 P. BANKOWSKI

Page 2: SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

FLOW

2 OF 2

TITLE:

SIZE: JOB NO.: DRAWING NUMBER: REV:

SCALE: WEIGHT: SHEET:1:2NC

WWW.MAZZEI.NET

MAZZEI INJECTOR CO., LLC

INJECTOR; MODEL SSC2081-M

B NA SSC02081MBB00-SUB

500 ROOSTER DRIVE BAKERSFIELD, CA 93307PHONE: (661) 363-6500 FAX: (661)363-7500

6 LBS

SUCTION PORT

(SIDE VIEW)

INLETOUTLET

3.93

12.41 (OVERALL)

(END VIEW)

3.00

4.26(OVERALL)

Page 3: SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

WELD MAP, NON DESTRUCTIVE TESTING (NDT), CLEANING AND 10.

SUBMITTAL DRAWING

INSPECTION REPORTS TO BE PROVIDED BY MAZZEI.

MAZZEI RECOMMENDS INSTALLING THE INJECTOR IN A HORIZONTAL 11.POSITION OR IN A VERTICAL POSITION WITH THE LIQUID FLOW UP. MAZZEI DOESN'T HAVE ANY PREFERENCE FOR THE POSITION OF THE GAS CONNECTION, IT CAN POINT IN ANY DIRECTION, TOP, BOTTOM OR ON THE SIDE.

NOTES:

MATERIAL OF CONSTRUCTION: CD3MN/2205 DUPLEX STAINLESS 1.STEEL

MTR/HEAT NUMBERS ARE PROVIDED "AS BUILT" AND SHALL MEET 2.APPLICABLE MATERIAL SPECIFICATIONS.

FLANGE BOLTS HOLES TO STRADDLE COMMON CENTERLINES, 3.UNLESS OTHERWISE NOTED.

INLET/OUTLET CONNECTION:4.2" DIA., ANSI B16.5, CLASS 150, SCHED. 40, RAISED FACE - WELD NECK FLANGE.

SUCTION PORT CONNECTION:5.1.25" DIA., ANSI B16.5, CLASS 150, SCHED. 40, RAISED FACE - WELD NECK FLANGE.

WELDING JOINTS TO BE COMPLETE JOINT PENETRATION, WHERE 6.POSSIBLE.

DYE PENETRANT TESTING IN ACCORDANCE WITH ASME B31.3 7.NORMAL SERVICE RECOMMENDATIONS WILL BE PERFORMED ON A MINIMUM OF 20% OF LINEAR LENGTH OF WELDS; OR HYDROSTATIC TESTING WILL BE PERFORMED AS PART OF MAZZEI'S NON-DESTRUCTIVE TESTING PROCEDURE.

CLEANED FOR PASSIVATION PER ASTM A380 GUIDELINES.8.

PASSIVATED PER ASTM A967 SPECIFICATION.9.

REVISIONSREV. DESCRIPTION DATE APPROVEDNC RELEASED FOR SUBMITTAL. 11/9/2012 P. BANKOWSKI

CONTAINING COMPONENTS MADE OR SOLD BY MAZZEI.

TITLE:

SIZE: JOB NO.: DRAWING NUMBER: REV:

SCALE: WEIGHT: SHEET:

.1/2WWW.MAZZEI.NET

MAZZEI INJECTOR CO., LLC

INJECTOR; MODEL SSC2081-M

B NA SSC02081MAA00-SUB NCNONE 1 OF 2

T. JOHNS

APPROVALS DATEDRAWN:

11/9/2012J. BENNETT

P. BANKOWSKI-

CHECKED:

APPROVED:

QA:

CUSTOMER:

11/9/201211/9/2012

NA

PHONE: (661) 363-6500 FAX: (661)363-7500

DO NOT SCALE

THIRD ANGLE PROJECTION

DRAWING MAY NOT BE PRINTED FULL SIZE

500 ROOSTER DRIVE BAKERSFIELD, CA 93307

REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF

1 PL

SUBMITTAL NOTICE

-

.125 2 PL

CUSTOMER APPROVAL:

THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OF

MAZZEI INJECTOR COMPANY LLC. ANYASME Y14.5M-1994

CONFIDENTIALITY NOTICE

INTERPRET DIM AND TOL PER .030 .060 3 PL

MAZZEI IS STRICTLY PROHIBITED.

UNLESS OTHERWISE SPECIFIEDDIM ARE IN INCHES

TOL ON ANGLE ANY RECOMMENDATIONS FOR PRODUCT AND/OR SYSTEM DESIGN, WHETHER CONTAINED IN A DOCUMENT, WITHIN THIS DRAWING, COMMUNICATED BY ELECTRONIC

MEANS OR GIVEN VERBALLY, ARE INTENDED SOLELY AS GUIDELINES TO ACTUAL SYSTEM DESIGN. SAID

RECOMMENDATIONS ARE BASED UPON INFORMATION SUPPLIED BY OTHERS, THE ACCURACY OF WHICH IS

BEYOND VERIFICATION BY MAZZEI INJECTOR CO. LLC. THEREFOR MAZZEI CANNOT AND DOES NOT WARRANT THE SUITABILITY OF ITS PRODUCTS FOR A PARTICULAR

SERVICE NOR THE PERFORMANCE OF ANY SYSTEM 21 LBS

(ISOMETRIC VIEW)(FOR REFERENCE ONLY)

Page 4: SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

FLOW

(END VIEW)

4.56

7.56(OVERALL)

(TOP VIEW)

2 OF 2

TITLE:

SIZE: JOB NO.: DRAWING NUMBER: REV:

SCALE: WEIGHT: SHEET:1:4NC

WWW.MAZZEI.NET

MAZZEI INJECTOR CO., LLC

INJECTOR; MODEL SSC2081-M

B NA SSC02081MAA00-SUB

500 ROOSTER DRIVE BAKERSFIELD, CA 93307PHONE: (661) 363-6500 FAX: (661)363-7500

21 LBS

OUTLETINLET

(SIDE VIEW)

SUCTION PORT

10.53 5.93

16.45 (OVERALL)

Page 5: SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

Mazzei Injector Company, LLC

Tel: 661.363.6500 Fax: 661.363.7500500 Rooster Drive, Bakers�eld, CA 93307

Page 6: SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

7/22/2004

InjectorInlet

InjectorOutlet

MotiveFlow GPM

WaterSuction

GPH

InjectorInlet

InjectorOutlet

MotiveFlow GPM

WaterSuction

GPH0 630 0 6311 630 5 6312 630 10 6313 215 15 6314 136 20 6310 630 30 6002 630 35 5095 468 40 3817 149 45 217

13600380 631 5 6315 623 10 6317 576 15 631

10 213 20 63112 77 30 6310 631 40 5295 631 45 440

10 468 50 32612 299 55 14215 152 0 6310 631 5 6315 631 10 631

10 627 15 63115 404 20 63120 134 30 6310 631 40 6045 631 50 506

10 631 60 27015 511 65 6120 341 0 631

136526520 631 10 6315 631 20 631

10 631 30 63115 627 40 63120 460 50 60225 256 60 4590 631 70 1795 631 75

10 631 0 63115 631 5 63120 524 10 63125 394 20 63130 169 30 6310 631 40 6315 631 50 622

10 631 60 59415 631 70 41220 607 80 12125 508 0 63130 341 5 63135 149 10 6310 631 20 6315 631 30 631

10 631 40 63115 631 50 63120 631 60 61225 588 70 59530 453 80 52335 300 90 30940 115 100

119

70 128

80 137

Mazzei Injector Company, LLC- Injector Performance TableInjector Model

40

Water Suction

5

10

60

Operating Pressure PSIG

2081

91

Water Suction Operating Pressure PSIG

153

145

34

48

100

97

90

68

158

25

30

35

77

84

103

50 108

45

120

15

20

59

Copyright Mazzei Injector Company, LLC June 2010500 Rooster Dr Bakersfield CA USA 661-363-6500 FAX 661-363-7500

Page 7: SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

7/22/2004

InjectorInlet

InjectorOutlet

MotiveFlowl/min

WaterSuction

LPH

InjectorInlet

InjectorOutlet

MotiveFlowl/min

WaterSuction

LPH0.00 2384 0.00 23870.07 2384 0.35 23870.14 2384 0.70 23870.21 812 1.05 23870.28 514 1.41 23870.00 2384 2.11 22730.14 2384 2.46 19250.35 1770 2.81 14410.49 565 3.16 8200.56 114 0.00 23870.00 2387 0.35 23870.35 2359 0.70 23870.49 2182 1.05 23870.70 807 1.41 23870.84 290 2.11 23870.00 2387 2.81 20020.35 2387 3.16 16670.70 1772 3.52 12350.84 1130 3.87 5381.05 574 0.00 23870.00 2387 0.35 23870.35 2387 0.70 23870.70 2372 1.05 23871.05 1529 1.41 23871.41 508 2.11 23870.00 2387 2.81 22870.35 2387 3.52 19150.70 2387 4.22 10201.05 1935 4.57 2301.41 1292 0.00 23871.76 234 0.35 23870.00 2387 0.70 23870.35 2387 1.41 23870.70 2387 2.11 23871.05 2372 2.81 23871.41 1741 3.52 22781.76 968 4.22 17360.00 2387 4.92 6780.35 2387 5.270.70 2387 0.00 23871.05 2387 0.35 23871.41 1982 0.70 23871.76 1493 1.41 23872.11 639 2.11 23870.00 2387 2.81 23870.35 2387 3.52 23530.70 2387 4.22 22471.05 2387 4.92 15611.41 2296 5.62 4571.76 1921 0.00 23872.11 1292 0.35 23872.46 564 0.70 23870.00 2387 1.41 23870.35 2387 2.11 23870.70 2387 2.81 23871.05 2387 3.52 23871.41 2387 4.22 23171.76 2225 4.92 22532.11 1714 5.62 19802.46 1135 6.33 11712.81 436 7.03

598

1.76

2.11

2.46

290

317

389

7.03

3.16

8.44

Operating Pressure kg/cm2 Water Suction Operating Pressure

kg/cm2

579

550

130

183

1.05

1.41

224

3.52 410

Mazzei Injector Company, LLC - Injector Performance TableInjector Model

2.81

Water Suction

0.35

0.70

4.22 449

2081

343

366

6.33

259

4.92 485

5.62 518

Copyright Mazzei Injector Company, LLC June 2010500 Rooster Dr Bakersfield CA USA 661-363-6500 FAX 661-363-7500

Page 8: SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

10/1/2010

InjectorInlet

InjectorOutlet

MotiveFlowGPM

AirSuctionSCFH

InjectorInlet

InjectorOutlet

MotiveFlowGPM

AirSuctionSCFH

64010056851766012224513103024

0 422 30 1522 230 35 1395 61 40 1277 48 45 1058 33 0 11290 523 5 9555 150 10 7907 80 15 56810 63 20 40512 41 30 1980 606 40 1525 244 45 14110 88 50 12512 79 55 9615 61 0 12020 670 5 10315 365 10 89410 137 15 69715 88 20 48520 52 30 2810 734 40 1755 468 50 15310 211 60 12015 107 65 8520 89 025 43 50 798 105 559 2010 287 3015 140 4020 107 5025 89 600 853 705 634 7510 344 015 199 520 124 1025 109 2030 85 300 899 405 696 5010 433 6015 259 7020 144 8025 12330 10935 800 9545 76110 51915 32120 19525 13930 12535 10940 74

50 104

35 87

40 93

100 147

45 98

20 66

80 131

25 73

30 80

90 139

5 33

60 114

10 46

Mazzei Injector Company, LLC - Injector Performance TableInjector Model 2081

Operating Pressure PSIG Air Suction Operating Pressure

PSIG Air Suction

70 123

15 57

Copyright Mazzei Injector Company, LLC June 2010500 Rooster Dr., Bakersfield, CA USA TEL 661-363-6500 FAX 661-363-7500

Page 9: SUBMITTAL NOTICE CONFIDENTIALITY NOTICE MAZZEI …€¦ · 1.25" dia., ansi b16.5, class 150, sched. 40, raised face - weld ... beyond verification by mazzei injector co. llc. therefor

10/1/2010

Injector Inlet InjectorOutlet

Motive Flow l/min

Air Suctionl/min Injector Inlet Injector

OutletMotive Flow

l/minAir Suction

l/min49400.000.080453.070.051307.041.099150.112.024114.182.02711.299100.06664.280141.00618.29253.09461.33294.033500.06165.015453.074200.037307.01753.086250.18394.019114.10307.03911.29148.02718.268200.07661.351153.09525.32407.05478.37348.076500.09250.178453.061300.022407.027153.092350.15607.092214.11450.123111.25214.13818.264300.02725.312253.07522.400107.00475.40550.1

00.02414.153.00267.107.077300.014.146253.011.253107.018.26650.125.31514.122.42467.129.430400.072.599253.000.026107.053.04950.107.09514.114.11567.111.20411.218.242400.025.392353.022.440207.029.422150.126.58614.1

8567.11511.28364.205400.095353.054207.025150.12914.16667.19511.22564.25318.2

3.52 394

2.46 329

2.81 352

7.03 556

3.16 371

1.41 250

5.62 496

1.76 276

2.11 303

6.33 526

0.35 125

4.22 431

0.7 174

4.92 466

1.05 216

Mazzei Injector Company, LLC - Injector Performance Table1802ledoM rotcejnI

Operating PressureKg/cm2 Air Suction Operating Pressure

Kg/cm2 Air Suction

Copyright Mazzei Injector Comnpany, LLC June 2010500 Rooster Dr., Bakersfield, CA USA TEL 661-363-6500 FAX 661-363-7500