2
M IN I S P LITS VRF PTAC SOLAR LE D LI G H T I N G YMGI Your Modern Green Idea YMGI Group • 601 Arrow Ln, O’Fallon, MO 63366 • [email protected] • ymgigroup.com • 866-833-3138 Submittal Data Sheet: WMMS-18KS-V2B(56) OUTDOOR UNIT WMMS-18CS-V2B(56) INDOOR UNIT ACCESSORIES ADVANCED HEALTHY KIT HEPA/Enzyme/Cold Catalyst Filter Anion Generator THERMOSTAT MOUNTING BRACKETS OOT RISERS COPPER/WIRE/ACC.SET LINESET COVERS WINTER WIND BAFFLE BRIDGE CONTROLLER Engineering Submittal Data Sheet: 11.01.2017 Document No. 2017.56.18K.001.A YMGI’s ductless 56 Series offers a quiet and efficient heating and cooling solution for any single room application with minimal impact to the environment. 56 Series units have a single zone mini split wall mounted unit and wall mount evaporator. The 56 Series can be wired directly to an array of solar panels (up to 5) to offset power consumption. The 56 Series create environmentally friendly comfortable living and working spaces. Includes U-Touch remote control. Specifications subject to change without notice Copyright © 2017 YMGI Group WMMS-18ES-V2B(56) WMMS-18PS-V2B(56) Connection Pipes Outer Diameter Liquid Pipe inches 1/4 Outer Diameter Gas Pipe inches 1/2 Max Distance ID Above ODU feet 50 Max Distance ID Below ODU feet 60 Max Distance Length feet 100 Dimensions & Weight Indoor Unit Dimensions-Net W x H x D inches 39.8 x 15.0 x 11.2 Net / Gross Weight lbs. 28.7 / 37.5 Dimensions & Weight Outdoor Unit Dimensions-Net W x H x D inches 35.0 x 27.6 x 13.4 Net /Gross Weight lbs. 110.1 / 121.1 Safety Certification ETL (C & US) Performance Certification AHRI Dimensions & Weight Solar Panel Dimension (W x H x D) inches 64.6 x 39.1 x 1.6 Net /Gross Weight lbs 37.0 / 52.9 COOLING HEATING System Model WMMS-18K-V2B(58)2 Power Source 208~230 / 1 / 60 Cooling Btu/h(L/M/H) 6000/18000/22350 Heating Btu/h(L/M/H) 4100/21000/24000 MCA Amp 13.2 Frequency (High / Medium / Low) Hz 80 / 57 / 15 75 / 65 / 15 Power Input (High / Medium / Low) W 1450 / 1000 / 120 1500 / 1200 / 220 Rated Current (High / Medium) A 7.0 / 5.2 7.5 / 6.0 SEER / HSPF Btu/h.w UP to 32 9.8 EER/COP Btu/h.w 15.1 4.1 Dehumidifying Volume Pints/Hr. 2.5 Outdoor Unit (ODU) Model WMMS-18C-V2B(58)2 Compressor Type Twin Rotary DC L.R.A. A 41 Compressor RLA A 8.4 Compressor Power Input W 1640 Overload Protector 1NT11L-3979 Throttling Method Electronic Expansion Valve HVAC Circuit Breaker A 30 Starting Method Transducer starting Recommended Working Ambient Temp Range °F 15°F ≤ T ≤115 °F 5°F ≤ T ≤ 86 °F Condenser Coil Type Aluminum fin-copper tube Fan Motor Speed (rpm) (H/L) 690 / 500 Output of Fan Motor W 60 Fan Motor RLA A 0.62 Fan Motor Capacitor uF 3 Air Flow Volume of Outdoor Unit CFM 1890 Defrosting Type Auto defrost Isolation I Moisture Protection IP24 MAX. Operating Pressure for Discharge Side PSIG 551 MAX. Operating Pressure for Suction Side PSIG 174 Sound Pressure Level (H/M/L) dBA 54 Sound Power Level dB (H/M/L) dBA 64 Indoor Unit (IDU) Model WMMS-18E-V2B(58)2 Fan Motor Speed (SH/H/M/L) RPM 1350 / 1200 / 1050 / 900 1420 /1250 / 1150 / 1050 Air Flow Volume (SH/H/M/L) CFM 500 / 460 / 383 / 324 Output of Fan Motor w 20 Fan Motor RLA A 0.25 Evaporator Coil Type Aluminum fin-copper tube Output of Swing Motor W 2.4 Fuse A PCB 3.15A Transformer 0.2A Sound Pressure Level (SH/H/M/L) dBA 40 / 36 / 32 / 26 Sound Power Level (SH/H/M/L) dBA 50 / 46 / 42 / 36 Solar Panel Model WMMS-18PS-V2B(56) Municipal Power Consumption, With No Solar Panels Installed Power Supply V/Ph/Hz 208-230/1/60 Power Input W(L/S/H) 300/1500/2500 335/1600/2550 Municipal Power Consumption, with Solar Panel Installed / tested at STC Solar Irradiance of 1000 W/m2 Power Input W (L/S/H) 30 / 400 / 650 30 / 500 / 700 Accepted Solar Panel - Power Data Ranges (All Panel of Same Model & Type) Open Circuit VoltageVoc (All PV Panels in Series) V 22~165 Short Circuit Current Isc (Per Panel) A 5~9 Nominal Power Output (STC Condition) Pmax (Per Panel) W 200 + (to 400) Power Output Tolerances (Per Panel) W -0 / +3 to +5 Allowed PV Panel W Mono-crystalline or Poly-silicon Allowed PV Panel Qty. in Series Pieces 1 to 5 (up to 1000 W) Recommended PV Panel Qty. Southern CA-FL / Northern CA, NC / OR-NY / WA-NE 2-4 / 3-5 / 4-5 / 5 Job Name: Tag #: Location Date: General Contractor: Mechanical Contractor: Sales Representative: Sales Engineer: Submitted by: Drawing #: Reference PO #:

Submittal Data Sheet: WMMS-18KS-V2B(56) · YMGI Group • 601 Arrow Ln, O’Fallon, MO 63366 • [email protected] • ymgigroup.com • 866-833-3138 Submittal Data Sheet: WMMS-18KS-V2B(56)

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Submittal Data Sheet: WMMS-18KS-V2B(56) · YMGI Group • 601 Arrow Ln, O’Fallon, MO 63366 • info@ymgigroup.com • ymgigroup.com • 866-833-3138 Submittal Data Sheet: WMMS-18KS-V2B(56)

MINI SPLITS • VRF • PTAC • SOLAR • LED LIGHTING

YMGIYour Modern Green Idea

YMGI Group • 601 Arrow Ln, O’Fallon, MO 63366 • [email protected] • ymgigroup.com • 866-833-3138

Submittal Data Sheet: WMMS-18KS-V2B(56)

OUTDOOR UNIT

WMMS-18CS-V2B(56)

INDOOR UNIT

ACCESSORIES

ADVANCED HEALTHY KIT HEPA/Enzyme/Cold Catalyst Filter Anion Generator

THERMOSTAT MOUNTING BRACKETS OOT RISERS COPPER/WIRE/ACC.SET LINESET COVERS WINTER WIND BAFFLE BRIDGE CONTROLLER

Engineering Submittal Data Sheet: 11.01.2017

Document No. 2017.56.18K.001.A

YMGI’s ductless 56 Series offers a quiet and efficient heating and cooling solution for any single room application with minimal impact to the environment. 56 Series units have a single zone mini split wall mounted unit and wall mount evaporator. The 56 Series can be wired directly to an array of solar panels (up to 5) to offset power consumption. The 56 Series create environmentally friendly comfortable living and working spaces. Includes U-Touch remote control.

Specifications subject to change without notice Copyright © 2017 YMGI Group

WMMS-18ES-V2B(56)

WMMS-18PS-V2B(56)

Connection PipesOuter Diameter Liquid Pipe inches 1/4

Outer Diameter Gas Pipe inches 1/2

Max Distance ID Above ODU feet 50

Max Distance ID Below ODU feet 60

Max Distance Length feet 100

Dimensions & Weight Indoor UnitDimensions-Net W x H x D inches 39.8 x 15.0 x 11.2

Net / Gross Weight lbs. 28.7 / 37.5

Dimensions & Weight Outdoor UnitDimensions-Net W x H x D inches 35.0 x 27.6 x 13.4

Net /Gross Weight lbs. 110.1 / 121.1

Safety Certification ETL (C & US)

Performance Certification AHRI

Dimensions & Weight Solar PanelDimension (W x H x D) inches 64.6 x 39.1 x 1.6

Net /Gross Weight lbs 37.0 / 52.9

COOLING HEATINGSystem Model WMMS-18K-V2B(58)2Power Source 208~230 / 1 / 60Cooling Btu/h(L/M/H) 6000/18000/22350Heating Btu/h(L/M/H) 4100/21000/24000MCA Amp 13.2Frequency (High / Medium / Low) Hz 80 / 57 / 15 75 / 65 / 15Power Input (High / Medium / Low) W 1450 / 1000 / 120 1500 / 1200 / 220Rated Current (High / Medium) A 7.0 / 5.2 7.5 / 6.0SEER / HSPF Btu/h.w UP to 32 9.8EER/COP Btu/h.w 15.1 4.1Dehumidifying Volume Pints/Hr. 2.5Outdoor Unit (ODU) Model WMMS-18C-V2B(58)2Compressor Type Twin Rotary DCL.R.A. A 41Compressor RLA A 8.4Compressor Power Input W 1640Overload Protector 1NT11L-3979 Throttling Method Electronic Expansion ValveHVAC Circuit Breaker A 30Starting Method Transducer startingRecommended Working Ambient Temp Range °F 15°F ≤ T ≤115 °F 5°F ≤ T ≤ 86 °FCondenser Coil Type Aluminum fin-copper tubeFan Motor Speed (rpm) (H/L) 690 / 500Output of Fan Motor W 60Fan Motor RLA A 0.62Fan Motor Capacitor uF 3Air Flow Volume of Outdoor Unit CFM 1890Defrosting Type Auto defrostIsolation IMoisture Protection IP24MAX. Operating Pressure for Discharge Side PSIG 551MAX. Operating Pressure for Suction Side PSIG 174Sound Pressure Level (H/M/L) dBA 54Sound Power Level dB (H/M/L) dBA 64Indoor Unit (IDU) Model WMMS-18E-V2B(58)2Fan Motor Speed (SH/H/M/L) RPM 1350 / 1200 / 1050 / 900 1420 /1250 / 1150 / 1050Air Flow Volume (SH/H/M/L) CFM 500 / 460 / 383 / 324Output of Fan Motor w 20Fan Motor RLA A 0.25Evaporator Coil Type Aluminum fin-copper tubeOutput of Swing Motor W 2.4Fuse A PCB 3.15A Transformer 0.2ASound Pressure Level (SH/H/M/L) dBA 40 / 36 / 32 / 26Sound Power Level (SH/H/M/L) dBA 50 / 46 / 42 / 36Solar Panel Model WMMS-18PS-V2B(56)Municipal Power Consumption, With No Solar Panels InstalledPower Supply V/Ph/Hz 208-230/1/60Power Input W(L/S/H) 300/1500/2500 335/1600/2550Municipal Power Consumption, with Solar Panel Installed / tested at STC Solar Irradiance of 1000 W/m2Power Input W (L/S/H) 30 / 400 / 650 30 / 500 / 700Accepted Solar Panel - Power Data Ranges (All Panel of Same Model & Type)Open Circuit VoltageVoc (All PV Panels in Series) V 22~165Short Circuit Current Isc (Per Panel) A 5~9Nominal Power Output (STC Condition) Pmax (Per Panel) W 200 + (to 400)Power Output Tolerances (Per Panel) W -0 / +3 to +5Allowed PV Panel W Mono-crystalline or Poly-siliconAllowed PV Panel Qty. in Series Pieces 1 to 5 (up to 1000 W)Recommended PV Panel Qty.Southern CA-FL / Northern CA, NC / OR-NY / WA-NE 2-4 / 3-5 / 4-5 / 5

Job Name: Tag #:

Location Date:

General Contractor: Mechanical Contractor:

Sales Representative: Sales Engineer:

Submitted by: Drawing #:

Reference PO #:

Page 2: Submittal Data Sheet: WMMS-18KS-V2B(56) · YMGI Group • 601 Arrow Ln, O’Fallon, MO 63366 • info@ymgigroup.com • ymgigroup.com • 866-833-3138 Submittal Data Sheet: WMMS-18KS-V2B(56)

W

W1

D

D1

H

D2

W2

Submittal Data Sheet: WMMS-18KS-V2B(56)

MINI SPLITS • VRF • PTAC • SOLAR • LED LIGHTING

YMGIYour Modern Green Idea

YMGI Group • 601 Arrow Ln, O’Fallon, MO 63366 • [email protected] • ymgigroup.com • 866-833-3138Specifications subject to change without notice Copyright © 2017 YMGI Group

(Top view)

(Bottom view)Tube exit option-right

(Right view)(Left view)(Front view)

D

Tube exit option-left

18K27.3 In

11.4 In

OUTDOOR UNIT

INDOOR UNIT

MOUNTING PLATE

Dimensions (inches)

W 30”

W1 33 13/32”

W2 21 5/16”

H 21 5/16”

D 10 3/32”

D1 12 19/32”

D2 11 5/16”

Dimensions (inches)

W 33 5/16”

H 10 13/16”

D 7 3/32”

YMGI Group 601 Arrow Ln, O’Fallon, Missouri 63366Phone: 1-866-833-3138Fax: 1-866-377-3355ymgigroup.com

Sales Representative or Distributor:

FEATURES• Minimized municipal power usage. As low as 30W. • PV panel DC power, supplemented by municipal power.

(Municipal electricity is required for stable power source.)• Advanced temperature, comfort and safety control• Can be integrated to work with existing solar panels• R410A refrigerant and constructed from environment friendly materials.• Solar panel installations eligible for Federal tax credit and/or State and/or

utility company’s rebate/incentive programs • Quiet and efficient heating & cooling• LED display shows set temperature & operating modes• Motorized louver system quietly distributes air evenly • “U-TOUCH” Remote Control

• DC Inverter technology • Wide working ambient temperature ranges • Stylish system design• Compact outdoor unit with side discharge • Outdoor unit ships pre-charged. • High quality compressors• Durable powder coated cabinet • Default flare brass connection valves • Knock-outs for refrigerant pipes and wiring• Built to ETL/UL/CSA/ARI standards• Easy installation and maintenance

W

L

D

SOLAR PANELDimensions (inches)

L 6419/32”

W 39 3/32”

D 1 19/32”

TERMINAL BLOCK

L1 L2 S L+ L-

Solar power input