4
 STRUCTURE1 LAB REPORT BUCKLING TEST Name: Choomka Zaynab Student’s ID Number: SCM  014146 Course: BEng (Hons) Civil Engineering Subject Title: Structure 1 Subject Code: ECS 3213 Name of Lecturer: Dr. Kousay Due date: 21 st March 2012

STRUCTURE1 LAB REPORT buckling test

Embed Size (px)

Citation preview

7/27/2019 STRUCTURE1 LAB REPORT buckling test

http://slidepdf.com/reader/full/structure1-lab-report-buckling-test 1/4

 

STRUCTURE1 LAB REPORT

BUCKLING TEST

Name: Choomka Zaynab

Student’s ID Number: SCM – 014146

Course: BEng (Hons) Civil Engineering

Subject Title: Structure 1

Subject Code: ECS 3213

Name of Lecturer: Dr. Kousay

Due date: 21st

March 2012

7/27/2019 STRUCTURE1 LAB REPORT buckling test

http://slidepdf.com/reader/full/structure1-lab-report-buckling-test 2/4

Objective:

1. To determine critical buckling loads for columns with support.

2. To examination the Euler theory of buckling.

3. To investigate the influence of different material parameters.

Introduction:

All relevant buckling problems can be demonstrated with the WP 120test stand. Buckling, as opposed to simple strength problems such as

drawing, pressure, bending and shearing, is primarily a stability

 problem. Buckling problem number among the best-known technical

examples in stability theory. Buckling plays an important role in almost

every field of technology. Examples of this are:

- Columns and supports in construction and steel engineering

- Stop rods for valve actuation and connecting rods in motor 

construction

- Piston rods for hydraulic cylinders and

- Lifting spindles in lifting gear 

7/27/2019 STRUCTURE1 LAB REPORT buckling test

http://slidepdf.com/reader/full/structure1-lab-report-buckling-test 3/4

Results

Length of rod = 650 mm

Width of rod = 17.3 mm

Diameter of rod = 1.3 mm

Modulus of elasticity = 210 000 N/mm

Deflection/mm 0 0.3 0.46 0.65 0.88 1.14 1.40 1.67 2.06 2.5 3.05

Force/N 0 50 100 150 200 250 300 350 400 450 500

Critical buckling force (Euler formula),

Fkrit = /  

=()()

()

 

= 31.7 N

Slenderness,

λ =

 

=()

 

= 700

7/27/2019 STRUCTURE1 LAB REPORT buckling test

http://slidepdf.com/reader/full/structure1-lab-report-buckling-test 4/4

Safety precautions:

· The load cross arm can drop of the clamping screws are loosened!

· A drop could damage parts of the testing machine located underneath

the cross arm.

· Carefully support the cross arm by hand when loosening the clamping

screws!

· Before removing a rod specimen make sure that the clamping screws

are tightened securely! Pay attention to the top thrust piece whenremoving the rod specimen!

· The hazards mentioned do not apply when the test device is set up

horizontally.

· Caution when working with brittle materials!

· The rod specimen could break suddenly in this case. Pieces of 

specimen could fly around and cause injuries.