45
Strowger selector operation diagrams contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final selector - just after seizure 4 Final selector - vertical stepping 5 Final selector - end of vertical stepping 6 Final selector - switch over to rotary 7 Final selector - rotary stepping 8 Final selector - end of rotary steps 9 Subscriber’s uniselector with double homing arc 10 Final selector - called line is free 11 Final selector - ringing a free line 12 Final selector - call answered 13 Caller’s uniselector - lifting the handset 14 Caller’s uniselector - hunting for free group selector 15 Caller’s uniselector - free group selector found 16 Caller’s uniselector - call established 17 Caller’s uniselector - call terminates 18 Subscriber’s uniselector with single homing arc 19 Uniselector - incoming call 20 Uniselector - P guarding during ringing 21 Uniselector - caller lifts handset 22 Uniselector - free 1 st selector found 23 Uniselector - connected 24 Uniselector - end of call 25 UAX13 group selector - idle state 26 UAX13 group selector - moment of seizure 27 UAX13 group selector - preparing for dial pulses 28 UAX13 group selector - end of vertical stepping 29 UAX13 group selector - free next selector found 30 UAX13 group selector - connecting to next selector 31 Ordinary group selector 200 outlet 32 Ordinary group selector - moment of seizure 33 Ordinary group selector - vertical stepping 34 Ordinary group selector - end of vertical stepping 35 Ordinary group selector - first rotary step 36 Ordinary group selector - free outlet found 37 Ordinary group selector - connecting 38 Ordinary group selector - normal release 39 UAX13 group selector and ordinary final selector 40 When group and final selector are both UAX13 41 UAX13 group selector - moment of connection 42 UAX13 group selector - providing 150 Ohm battery 43 UAX13 group selector - external relay activation 44 UAX13 group selector - connection made 45

Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

  • Upload
    others

  • View
    25

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

Strowger selector operation diagrams – contents

1

Ordinary final selector - idle state 2

Final selector - moment of seizure 3

Final selector - just after seizure 4

Final selector - vertical stepping 5

Final selector - end of vertical stepping 6

Final selector - switch over to rotary 7

Final selector - rotary stepping 8

Final selector - end of rotary steps 9

Subscriber’s uniselector with double homing arc 10

Final selector - called line is free 11

Final selector - ringing a free line 12

Final selector - call answered 13

Caller’s uniselector - lifting the handset 14

Caller’s uniselector - hunting for free group selector 15

Caller’s uniselector - free group selector found 16

Caller’s uniselector - call established 17

Caller’s uniselector - call terminates 18

Subscriber’s uniselector with single homing arc 19

Uniselector - incoming call 20

Uniselector - P guarding during ringing 21

Uniselector - caller lifts handset 22

Uniselector - free 1st selector found 23

Uniselector - connected 24

Uniselector - end of call 25

UAX13 group selector - idle state 26

UAX13 group selector - moment of seizure 27

UAX13 group selector - preparing for dial pulses 28

UAX13 group selector - end of vertical stepping 29

UAX13 group selector - free next selector found 30

UAX13 group selector - connecting to next selector 31

Ordinary group selector 200 outlet 32

Ordinary group selector - moment of seizure 33

Ordinary group selector - vertical stepping 34

Ordinary group selector - end of vertical stepping 35

Ordinary group selector - first rotary step 36

Ordinary group selector - free outlet found 37

Ordinary group selector - connecting 38

Ordinary group selector - normal release 39

UAX13 group selector and ordinary final selector 40

When group and final selector are both UAX13 41

UAX13 group selector - moment of connection 42

UAX13 group selector - providing 150 Ohm battery 43

UAX13 group selector - external relay activation 44

UAX13 group selector - connection made 45

Page 2: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+

CD2200

N3

P wire

B2

A1

1300

B4

MR2

R2

200

B

CD1

5 700

B1

R3

1k2

E3

CD

N2

NR2

F6

1500E

E5

CD4

E1//D1

NR1

VM

H5

RM

Ordinary final selector – idle state

METER PULSE

CONNECTION

HERE

ROTARY

RELEASE

CONNECTION

TO F, H AND

J RELAYS

2

Page 3: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+

CD2200

N3

P

B2

A1

1300

B4

MR2

R2

B

CD1

5 700

B1

R3

E3

CD

N2

NR2

F6

E

E5

CD4

E1

NR1

VM

H5

RM

Final selector – moment of seizure – A operates and removes short-circuit of B

3

1500

CURRENT FLOW

IN RED

Page 4: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+CD2 200

N3

P

B2

A1

1300

B4

MR2

R2

B

CD1

5 700

B1

R3

E3

CD

N2

NR2

F6

1500E

E5

CD4

E1

NR1

VM

H5

RM

Final selector – just after seizure – A, B and CD operate

INCOMING

PRIVATE WIRE

EARTHED

4

Page 5: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+CD2 200

N3

P

B2

A1

1300

B4

MR2

R2

B

CD1

5 700

B1

R3

1k2

E3

CD

N2

NR2

F6

1500E

E5

CD4

E1

NR1

VM

H5

RM

Final selector – vertical stepping – A and VM are pulsing, B and CD are holding on short circuits

short-

circuit

5

Page 6: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+CD2 200

N3

P

B2

A1

1300

B4

MR2

R2

B

CD1

5 700

B1

R3

E3

CD

N2

NR2

F6

1500E

E5

CD4

E1

NR1

VM

H5

RM

Final selector – end of vertical stepping – A and B operate, CD releases, E slow to operate

6

Page 7: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+CD2 200

N3

P

B2

A1

1300

B4

MR2

R2

B

CD1

5 700

B1

R3

E3

CD

N2

NR2

F6

1500E

E5

CD4

E1

NR1

VM

H5

RM

Final selector – switch over to rotary – A, B and E operate, CD re-operates

short-circuit on

CD removed

7

Page 8: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+CD2 200

N3

P

B21300

B4

MR2

R2

B

CD1

5 700

B1

R3

1k2

E3

CD

N2

NR2

F6

1500E

E5

CD4

E1

NR1

VM

H5

RM

Final selector – rotary stepping – A and RM pulsing, B and CD holding, E operates

A1

8

Page 9: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+CD2 200

N3

P

B21300

B4

MR2

R2

B

CD1

5 700

B1

R3

E3

CD

N2

NR2

F6

1500E

E5

CD4

E1

NR1

VM

H5

RM

Final selector – end of rotary steps – A and B operate, CD and E release slowly, CD re-operates

A1

9

Page 10: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

_

+

700

DMdm

DM

Subscriber’s uniselector with DOUBLE homing arc – idle state

L

1300K

L2

K3

K5

L1x

H

K1

K2

P

H4

H3

+

_

M.D.F.LINE SIDE EXCH SIDE

M.D.F.

MULT. LOCALB3

CD3

H

P

FINAL SELECTOR

SUBSCRIBER’S UNISELECTOR

-50V

10

Page 11: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

_

+

700

DMdm

DM

Final selector – called line is free – CD releases, H (900 Ohm) and K operate, L is disconnected

L

1300K

L2

K3

K5

L1x

H

K1

K2

P

H4

H3

+

_

M.D.F.LINE SIDE EXCH SIDE

M.D.F.

MULT. LOCALB3

CD3

H

P

FINAL SELECTOR

(after last digit dialled)

CALLED SUBSCRIBER’S UNISELECTOR

900

PREPARED FOR RINGING

IF NOT ENGAGEDCALLED

PHONE11

Ringing current in green

Page 12: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

Final selector – ringing a free line – E releases slowly, CD, J and H (on 400 Ohm winding) operate

300

D

J3

RING TONE

TO CALLER

E4

F5

+

P

_

R1

400F

H400 900

H3

H4

F7

F8

F1F2

H1

B4

F4x

B3

CD3

H2

570 200A 200

N2

J800

J1

INT RING

TO CALLED

BELL

VM

D1

E

CD4

RING RTN

BATTERYHOLDING

UNISELECTOR

K RELAY

1500

12

Page 13: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

Final selector – call answered – CD, D, E and F operate, J releases (slowly) after meter pulse

300

D

J3

+

P

_

R1

400F

H400 900

H3

H4

F7

F8

F1F2

H1

B4

F4x

B3

H2

570 200A 200

N2

J800

J1

INT RING

E

VM

CD4

D1

VOICE CONNECTION

HOLDING

UNISELECTOR

K RELAY

CD3

RING TONE

TO CALLER

F5

E4

1500

13

Page 14: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

DMdmDM

Caller’s uniselector – lifting the handset – L operates slowly

1300K

L2

K3

K5

L1x

H

P

M.D.F.

MULT. LOCAL

B3

CD3

H

P

_

+

700

K1

K2

H4

H3

+

_

L

CALLER

LINE SIDE EXCH SIDE

CALLER’S UNISELECTORMULTIPLE FINAL SELECTORS

TO GROUP

SELECTORS

GUARDED

GROUP

SELECTORS

14

Page 15: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

DMdmDM

Caller’s uniselector – hunting for free group selector - L operates, DM pulsing

1300K

L2

K3

K5

L1x

HP

M.D.F.

MULT. LOCAL

B3

CD3

H

P

_

+

700

K1

K2

H4

H3

+

_

L

CALLER

LINE SIDE EXCH SIDE

CALLER’S UNISELECTORMULTIPLE FINAL SELECTORS

P WIRE

MULTIPLE

EARTHED

VIA HOMING

ARC HOME

POSITION

TO GROUP

SELECTORS

GUARDED

GROUP

SELECTORS

15

Page 16: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

DMdmDM

Caller’s uniselector – free group selector found – K operates, L releases slowly

1300K

L2

K3

K5

L1x

H

P

M.D.F.

MULT. LOCAL

B3

CD3

H

P

_

+

700

K1

K2

H4

H3

+

_

L

CALLER

LINE SIDE EXCH SIDE

CALLER’S UNISELECTORMULTIPLE FINAL SELECTORS

P WIRE

MULTIPLE

EARTHED

VIA HOMING

ARC

GUARDED

GROUP

SELECTORS

LOOP CURRENT

FROM GROUP

SELECTOR

L2 AND K3 PROVIDE

TEMPORARY EARTH

TO SEIZED SELECTOR

16

Page 17: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

DMdmDM

Caller’s uniselector – call established – K held by group selector P wire

1300K

L2

K3

K5

L1x

H

P

M.D.F.

MULT. LOCAL

B3

CD3

H

P

_

+

700

K1

K2

H4

H3

+

_

L

CALLER

LINE SIDE EXCH SIDE

CALLER’S UNISELECTORMULTIPLE FINAL SELECTORS

P WIRE

MULTIPLE

EARTHED

VIA HOMING

ARC

LOOP CURRENT

FROM GROUP

SELECTOR

SEIZED SELECTOR

RETURNS EARTH

17

Page 18: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

DMdmDM

Caller’s uniselector - call terminates - no loop current – K releases – DM steps home

1300K

L2

K3

K5

L1x

H

P

M.D.F.

MULT. LOCAL

B3

CD3

H

P

_

+

700

K1

K2

H4

H3

+

_

L

CALLER

LINE SIDE EXCH SIDE

CALLER’S UNISELECTORMULTIPLE FINAL SELECTORS

P WIRE

MULTIPLE

EARTHED

VIA HOMING

ARC

18

Page 19: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

_

+

700

DMdm

DM

Subscriber’s uniselector with SINGLE homing arc - idle state - H, K and L not operating

L

1300K

L2

K3

K5

L1

H

K1

K2

P

H4

H3

+

_

M.D.F.LINE SIDE EXCH SIDE

M.D.F.

MULT. LOCALB3

CD3

H

P

FINAL SELECTOR

SUBSCRIBER’S UNISELECTOR

900

400

BELL

LOOP

- 50V

19

Page 20: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

_

+

700

Uniselector – incoming call – H (900) operates on brief CD release, K operates, L releases

L

K1

K2H4

H3

+

_

M.D.F.LINE SIDE EXCH SIDE

M.D.F.

MULT. LOCALB3

CD3

H

P

FINAL SELECTOR

(last digit dialled)

CALLED SUBSCRIBER’S UNISELECTOR

900

PREPARED FOR RINGING

IF NOT ENGAGED

DMdm

DM

1300K

K3

K5

L1

H

P

L2

BELL

LOOP20

Page 21: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

_

+

700

Uniselector– P guarding during ringing – CD operates again, H(400) takes over from H(900)

L

K1

K2H4

H3

+

_

M.D.F.LINE SIDE EXCH SIDE

M.D.F.

MULT. LOCALB3

CD3

H

P

FINAL SELECTOR

CALLED SUBSCRIBER’S UNISELECTOR

900

PREPARED FOR RINGING

IF NOT ENGAGED

DMdm

DM

1300K

K3

K5

L1

H

P

L2

BELL

LOOP

H2

400

21

Page 22: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

_

+

700

DMdm

DM

Uniselector – caller lifts handset – L operates on caller loop, DM steps on DMdm

L

1300K

L2

K3

K5

L1

H

K1

K2

P

H4

H3

+

_

M.D.F.LINE SIDE EXCH SIDE

M.D.F.

MULT. LOCALB3

CD3

H

P

FINAL SELECTOR

CALLING SUBSCRIBER’S UNISELECTOR

900

400

CALLER

LOOP22

Page 23: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

_

+

700

DMdm

DM

Uniselector – free 1st selector found – K operates, L releases slowly

L

1300K

L2

K3

K5

L1

H

K1

K2

P

H4

H3

+

_

M.D.F.LINE SIDE EXCH SIDE

M.D.F.

MULT. LOCALB3

CD3

H

P

FINAL SELECTOR

CALLING SUBSCRIBER’S UNISELECTOR

900

400

CALLER

LOOP

FREE 1st

SELECTOR

1st

SELECTOR

LOOP

23

Page 24: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

_

+

700

DMdm

DM

Uniselector – connected – K operates on 1st selector earth

L

1300K

L2

K3

K5

L1

H

K1

K2

P

H4

H3

+

_

M.D.F.LINE SIDE EXCH SIDE

M.D.F.

MULT. LOCALB3

CD3

H

P

FINAL SELECTOR

CALLING SUBSCRIBER’S UNISELECTOR

900

400

CALLER

LOOP

FREE 1st

SELECTOR

EARTH

RETURNED

1st

SELECTOR

LOOP

24

Page 25: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

_

+

700

DMdm

DM

Uniselector – end of call – P earth removed, K releases, DM steps home

L

1300K

L2

K3

K5

L1

H

K1

K2

P

H4

H3

+

_

M.D.F.LINE SIDE EXCH SIDE

M.D.F.

MULT. LOCALB3

CD3

H

P

FINAL SELECTOR

CALLING SUBSCRIBER’S UNISELECTOR

900

400

OPEN

LOOP

FREE 1st

SELECTOR

EARTH

REMOVED

25

Page 26: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+

200

P

B1

2000 2000

2000

YC

2k

C

1300B

VMRM

UAX13 group selector – idle state

RELEASE

RELAY

_

+

M

P

570M

3 1000

11

1000

MRA

VMB

CBO

CB

NR1

H

N3

S1

TM1

B2B5

C3

H2HX1

CC4

H4

R1

N1

200

QA

N2

CC

HX

B3

H3 B4

CC3

TM2

TM

YA

150 YB

500

CC2

H1

C2

CC1

H5H6

S2

S3CC5

H7

TP

HOLD

TP

STARTRELEASE

ALARM

EARTH

TP RELEASE

DIAL TONE EARTH

N.U. TONE EARTH

BUSY TONE EARTH

INT BATT & EARTH

A1

C1

(AT BATT LEVEL)

26

Page 27: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+

200

P

B1

2000 2000

2000

YC

2k

C

1300B

VMRM

UAX13 group selector – moment of seizure – A and B operate

RELEASE

RELAY

_

+

M

P

570M

3 1000

11

1000

MRA

VMB

CBO

CB

NR1

H

N3

S1

TM1

B2B5

C3

H2HX1

CC4

H4

R1

N1

200

QA

N2

CC

HX

B3

H3 B4

CC3

TM2

TM

YA

150 YB

500

CC2

H1

C2

CC1

H5H6

S2

S3CC5

H7

TP

HOLD

TP

STARTRELEASE

ALARM

EARTH

TP RELEASE

DIAL TONE EARTH

N.U. TONE EARTH

BUSY TONE EARTH

INT BATT & EARTH

A1

C1

(AT EARTH LEVEL)

27

Page 28: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+

200

P

B1

2000 2000

2000

YC

2k

C

1300B

VMRM

UAX13 group selector – preparing for dial pulses – C and CC operate

RELEASE

RELAY

_

+

M

P

570M

3 1000

11

1000

MRA

VMB

CBO

CB

NR1

H

N3

S1

TM1

B2B5

C3

H2HX1

CC4

H4

R1

N1

200

QA

N2

CC

HX

B3

H3 B4

CC3

TM2

TM

YA

150 YB

500

CC2

H1

C2

CC1

H5H6

S2

S3CC5

H7

TP

HOLD

TP

STARTRELEASE

ALARM

EARTH

TP RELEASE

DIAL TONE EARTH

N.U. TONE EARTH

BUSY TONE EARTH

INT BATT & EARTH

A1

C1

28

Page 29: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+

200

P

B1

2000 2000

2000

YC

2k

C

1300B

VMRM

UAX13 group selector – end of vertical stepping – C, CC release, hunting for free outlet

RELEASE

RELAY

_

+

M

P

570M

3 1000

11

1000

MRA

VMB

CBO

CB

NR1

H

N3

S1

TM1

B2B5

C3

H2HX1

CC4

H4

R1

N1

200

QA

N2

CC

HX

B3

H3 B4

CC3

TM2

TM

YA

150 YB

500

CC2

H1

C2

CC1

H5H6

S2

S3CC5

H7

TP

HOLD

TP

STARTRELEASE

ALARM

EARTH

TP RELEASE

DIAL TONE EARTH

N.U. TONE EARTH

BUSY TONE EARTH

INT BATT & EARTH

A1

C1

E.G. DIALLED 6

E.G. NR 3 IS FREE

29

Page 30: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+

200

P

B1

2000 2000

2000

YC

2k

C

1300B

VMRM

UAX13 group selector – free next selector found – HX operates on P wire battery(!)

RELEASE

RELAY

_

+

M

P

570M

3 1000

11

1000

MRA

VMB

CBO

CB

NR1

H

N3

S1

TM1

B2B5

C3

H2HX1

CC4

H4

R1

N1

200

QA

N2

CC

HX

B3

H3 B4

CC3

TM2

TM

YA

150 YB

500

CC2

H1

C2

CC1

H5H6

S2

S3CC5

H7

TP

HOLD

TP

STARTRELEASE

ALARM

EARTH

TP RELEASE

DIAL TONE EARTH

N.U. TONE EARTH

BUSY TONE EARTH

INT BATT & EARTH

A1

C1

E.G. DIALLED 6

E.G. NR 3 IS FREE

P wire

on batt !!

30

Page 31: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

200A

_

+

200

P

B1

2000 2000

2000

YC

2k

C

1300B

VMRM

UAX13 group selector – connecting to next selector – H operates, HX, A and B release

RELEASE

RELAY

_

+

M

P

570M

3 1000

11

1000

MRA

VMB

CBO

CB

NR1

H

N3

S1

TM1

B2B5

C3

H2HX1

CC4

H4

R1

N1

200

QA

N2

CC

HX

B3

H3 B4

CC3

TM2

TM

YA

150 YB

500

CC2

H1

C2

CC1

H5H6

S2

S3CC5

H7

TP

HOLD

TP

STARTRELEASE

ALARM

EARTH

TP RELEASE

DIAL TONE EARTH

N.U. TONE EARTH

BUSY TONE EARTH

INT BATT & EARTH

A1

C1

E.G. DIALLED 6

E.G. NR 3 IS FREE

P wire

earthed

31

Page 32: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

1500

A

_

+

750

Ordinary group selector 200 outlet – idle state_

+

P1

400

S2

CD5

200

N1

DIAL TONE EARTH

BUSY TONE EARTH

200

570

HA5

B6

CD6

NR2

NR3

HA2

_

+

P2

HA1

B4

B3

HB7

HB6

HB

1500 750 400

HB1

HA7

HB2

P

B5RM1

HA4HB5

NR1

RLSE

ALM

EARTH

B7

CD4

1300N2 B1

CD3

5700

RM

VM

CD2

B2

NR4

CD1

CD

B

A1

HA6HA3HB3

R2 200

R1 800

LP1

HA

R4 300

R3 500

C1

S1

32

Page 33: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

1500

A

_

+

750

Ordinary group selector – moment of seizure – A, B and CD operate_

+

P1

400

S2

CD5

200

N1

DIAL TONE EARTH

BUSY TONE EARTH

200

570

HA5

B6

CD6

NR2

NR3

HA2

_

+

P2

HA1

B4

B3

HB7

HB6

HB

1500 750 400

HB1

HA7

HB2

P

B5RM1

HA4HB5

NR1

RLSE

ALM

EARTH

B7

CD4

1300N2 B1

CD3

5700

RM

VM

CD2

B2

NR4

CD1

CD

B

A1

HA6HA3HB3

R2 200

R1 800

LP1

HA

R4 300

R3 500

C1

S1

33

Page 34: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

1500

A

_

+

750

Ordinary group selector – vertical stepping – N1, N2, HA and HB (750 Ohm) operate _

+

P1

400

S2

CD5

200

N1

DIAL TONE EARTH

BUSY TONE EARTH

200

570

HA5

B6

CD6

NR2

NR3

HA2

_

+

P2

HA1

B4

B3

HB7

HB6

HB

1500 750 400

HB1

HA7

HB2

P

B5RM1

HA4HB5

NR1

RLSE

ALM

EARTH

B7

CD4

1300N2 B1

CD3

5700

RM

VM

CD2

B2

NR4

CD1

CD

B

A1

HA6HA3HB3

R2 200

R1 800

LP1

HA

R4 300

R3 500

C1

S1

34

Page 35: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

1500

A

_

+

750

Ordinary group selector – end of vertical stepping – CD releases slowly, RM operates_

+

P1

400

S2

CD5

200

N1

DIAL TONE EARTH

BUSY TONE EARTH

200

570

HA5

B6

CD6

NR2

NR3

HA2

_

+

P2

HA1

B4

B3

HB7

HB6

HB

1500 750 400

HB1

HA7

HB2

P

B5RM1

HA4HB5

NR1

RLSE

ALM

EARTH

B7

CD4

1300N2 B1

CD3

5700

RM

VM

CD2

B2

NR4

CD1

CD

B

A1

HA6HA3HB3

R2 200

R1 800

LP1

HA

R4 300

R3 500

C1

S1

35

Page 36: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

1500

A

_

+

750

Ordinary group selector – first rotary step – RM1 breaks RM and HA/HB (750) circuits_

+

P1

400

S2

CD5

200

N1

DIAL TONE EARTH

BUSY TONE EARTH

200

570

HA5

B6

CD6

NR2

NR3

HA2

_

+

P2

HA1

B4

B3

HB7

HB6

HB

1500 750 400

HB1

HA7

HB2

P

B5RM1

HA4HB5

NR1

RLSE

ALM

EARTH

B7

CD4

1300N2 B1

CD3

5700

RM

VM

CD2

B2

NR4

CD1

CD

B

A1

HA6HA3HB3

R2 200

R1 800

LP1

HA

R4 300

R3 500

C1

ASSUME BOTH P1

AND P2 EARTHED

ON FIRST OUTLET:

HA AND HB HOLD

ON 400 OHM COIL

S1

36

Page 37: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

1500

A

_

+

750

Ordinary group selector – free outlet found – HA and HB release, CD re-operates _

+

P1

400

S2

CD5

200

N1

DIAL TONE EARTH

BUSY TONE EARTH

200

570

HA5

B6

CD6

NR2

NR3

HA2

_

+

P2

HA1

B4

B3

HB7

HB6

HB

1500 750 400

HB1

HA7

HB2

P

B5RM1

HA4HB5

NR1

RLSE

ALM

EARTH

B7

CD4

1300N2 B1

CD3

5700

RM

VM

CD2

B2

NR4

CD1

CD

B

A1

HA6HA3HB3

R2 200

R1 800

LP1

HA

R4 300

R3 500

C1

ASSUME BOTH P1

AND P2 ARE FREE

ON SECOND

OUTLET

S1

37

Page 38: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

1500

A

_

+

750

Ordinary group selector – connecting – A and B release, HA operates on 1500 Ohm coil _

+

P1

400

S2

CD5

200

N1

DIAL TONE EARTH

BUSY TONE EARTH

200

570

HA5

B6

CD6

NR2

NR3

HA2

_

+

P2

HA1

B4

B3

HB7

HB6

HB

1500 750 400

HB1

HA7

HB2

P

B5RM1

HA4HB5

NR1

RLSE

ALM

EARTH

B7

CD4

1300N2 B1

CD3

5700

RM

VM

CD2

B2

NR4

CD1

CD

B

A1

HA6HA3HB3

R2 200

R1 800

LP1

HA

R4 300

R3 500

C1

HA HOLDING ON

P WIRE EARTH

OF SUCCEEDING

SELECTOR

S1

38

Page 39: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

1500

A

_

+

750

Ordinary group selector – normal release – HA and CD release, RM steps home

P1

400

S2

CD5

200

N1

DIAL TONE EARTH

BUSY TONE EARTH

200

570

HA5

B6

CD6

NR2

NR3

HA2

P2

HA1

B4

B3

HB7

HB6

HB

1500 750 400

HB1

HA7

HB2

P

B5RM1

HA4HB5

NR1

RLSE

ALM

EARTH

B7

CD4

1300N2 B1

CD3

5700

RM

VM

CD2

B2

NR4

CD1

CD

B

A1

HA6HA3HB3

R2 200

R1 800

LP1

HA

R4 300

R3 500

C1

HA RELEASES ON

FREEING OF P

WIRE OF

SUCCEEDING

SELECTOR

S1

_

+

P1

_

+

P2

39

Page 40: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

P

2000 2000

RM

UAX13 Group Selector connected to an Ordinary Final Selector(Example: ATW 600670 connected to ATW 52160)

P

11

NR1

H

N2

S1

B3

H6HX1

N3

HX

B5

150

H7

A UAX13 GROUP SELECTOR EXPECTS A 150 OHM BATTERY

ON THE P WIRE OF A FREE FINAL SELECTOR TO OPERATE

RELAY HX.

A FREE ORDINARY FINAL SELECTOR DOES NOT PROVIDE

POWER ON ITS INCOMING P WIRE

U9

U10

U25

to Final Selector

40

Page 41: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

P

2000 2000

RM

When group selector and final selector are both UAX13 – HX operates on 150 Ohm P wire battery

P

11

NR1

H

N2

S1

B3

H6HX1

N3

HX

B5

150

H7

P wire

on batt !!

CURRENT FLOW SHOWN IN RED, JUST

AFTER HX OPERATES ON P WIRE

BATTERY

H CONTACTS NOT YET ACTIVATED

U9

U10

U25

41

Page 42: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

2000 2000

RM

UAX13 group selector – connecting to next selector – H operates, B and HX release

P

11

NR1

H

N2

S1

B3

H6HX1

N3

B5

150

H7

P wire gets

earthed

B RELEASES, P WIRE IS EARTHED BY

NEXT SELECTOR

H6 TAKES OVER FROM HX1

HX

P

U9

U10

U25

42

Page 43: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

P

2000 2000

RM

Providing 150 Ohm battery

P

11

NR1

H

N2

S1

B3

H6HX1

N3

HX

B5

150

H7

TEMPORARY BATTERY CAN BE ARRANGED BY

CONNECTING AN ADDITIONAL RELAY HY BETWEEN POINTS

U9 AND U10.

RELAY B (NOT SHOWN HERE) OPERATES WHEN THE

GROUP SELECTOR IS SEIZED. IT PUTS AN EARTH TO U9.

A 150 OHM BATTERY IS ALREADY AVAILABLE ON POINT U25.

HY1 CONNECTS THE BATTERY TO THE P BANK.

THE EXTERNAL RELAY IS ACTIVATED WHEN HX OPERATES

ON TESTING A FREE FINAL SELECTOR. THAT DISCONNECTS

THE BATTERY FROM THE P WIRE. BY THAT TIME THE FREE

FINAL SELECTOR IS SEIZED.

A CAPACITOR HAS BEEN ADDED TO DELAY THE SEQUENCE.

A RELAY WITH A SLUG MAY ALSO BE USED.

U9

U10

U25

to Final Selector

HY

HY1

47uF

160V

43

Page 44: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

P

2000 2000

RM

UAX13 group selector – additional external relay HY to provide temporary batt on P wire

P

11

NR1

H

N2

S1

B3

H6HX1

N3

HX

B5

150

H7

P wire

on batt !!

CURRENT FLOW SHOWN IN RED, JUST

AFTER HX OPERATES ON P WIRE

BATTERY

H CONTACTS AND HY1 NOT YET

ACTIVATED

RELAY HY: SONGLE SRD-48VDC-SL-C

ADDED 47uF CAPACITOR TO CONTACTS

TO SLOW THE RESPONSE

U9

U10

U25

HY1

HY

47uF

160V

44

Page 45: Strowger selector operation diagrams contents · Strowger selector operation diagrams –contents 1 Ordinary final selector - idle state 2 Final selector - moment of seizure 3 Final

2000 2000

RM

UAX13 group selector – connecting to ordinary selector – H and HY operate, B and HX release

P

11

NR1

H

N2

S1

B3

H6HX1

N3

B5

150

H7

P wire gets

earthed

CURRENT FLOW SHOWN IN RED, JUST

AFTER H OPERATES

B RELEASES, P WIRE EARTED BY NEXT

SELECTOR

H6 TAKES OVER FROM HX1

HX

P

U9

U10

U25

HY1

HY

47uF

160V

45