Upload
doanh
View
247
Download
5
Embed Size (px)
Citation preview
C O M M E R C I A L
State Commercial Storage Tanks are ideal for increasing storage capacitywhen used along with water heaters and domestic hot water heating boilers.
Meets or Exceeds the thermal efficiency and/or standbyloss requirements of the U.S. Department of Energy andcurrent edition of ASHRAE/IESNA 90.1
Foam Insulation - Thick foam insulation reduces stand-by heat loss andsaves energy.
Glass-Lined Tank - Alkaline borosilicate composition is permanently fusedto steel by firing at a temperature of 1600°F, and will provide years ofcorrosion protection and dependable use at water storage temperatures upto 180°F.
Heavy-Gauge Steel Jacket - With baked enamel finish.
Threaded Openings - All tanks furnished with threaded openings forthermometer, relief valve, 2˝ recirculation lines (2-1/2˝ openings are optionalon 119 gallon and 175 gallon models), tankstat, and drain valve.
Five-Year Warranty
Anode Rod - To provide additional corrosion protection and extra years ofservice, all 80 and 120 gallon models are equipped with an anode rod.Model PVG 0200 OVSA125 has two anode rods.
Installation - Sized to fit space restrictive installations, all 80 and 120gallon models fit through 30˝ doorways. Model PVG 0200 OVSA125 fitsthrough a 33˝ doorway.
Suggested SpecificationsStorage tank shall be a State glass-lined storage tank. Tank shall be _______˝ x _______˝ and have a nominal capacity of _____ gallons. Tank(s) shall have threadedopenings as shown on drawings. Interior of tank(s) shall be glass-lined with an alkaline borosilicate composition which has been fused to the steel by firing at atemperature of 1600˚F. Glass coating shall be continuous over the entire inner surface of the tank. Outer jacket shall have a baked enamel finish. Foam insulation tomeet or exceed ASHRAE current efficiency requirements. Cathodic protection shall be provided. Tank shall have a working pressure of ____ psi. Meets or exceedsthe thermal efficiency and/or standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1
Storage TanksStandard Jacketed Storage Tanks
For more information on State® contact:State Water Heaters500 Tennessee Waltz Parkway, Ashland City, TN 37015800.365.0024 Toll-free USAwww.statewaterheaters.com
STMSS00307 August 2008R ©2008 State Industries, Inc.
193579_STMSS00307.indd 1193579_STMSS00307.indd 1 8/18/08 11:40:14 AM8/18/08 11:40:14 AM
C O M M E R C I A L
5 erugiF4 erugiF3 erugiF
2 erugiF1 erugiF
A B
C
D
E
F
F
3⁄4˝NPT
1˝ NPT
HANDHOLECLEANOUT
3⁄4˝ NPTPLUG ANODE
CLEANOUT
T&P OPENING
F
3⁄4˝ NPTPLUG ANODE
CIRCULATINGFITTINGS
DRAIN &AQUASTAT 30°
15°15°
A B
C
D
E
F
F
F
3⁄4˝NPT
31⁄2˝
111⁄2˝
G
1˝ NPT
11⁄4˝ NPTPLUG ANODE
ASME PLATE(ON PVG 01200 OVTA)
T&P OPENING
F
1˝ NPT(PVG 01200 OVTA)
30° 45°
SPECIFICATIONSNominal Standard Approx. Refer Dimensions In Inches
Model Gallon ASME Working toCapacity Pressure Ship. Wt. Figure A B C D E F G
PVG 0080 0OVT - Jacketed Vertical Only 2 —
A B
C
D
E
F
F
F
3⁄4˝NPT
10˝
111⁄2˝G
1˝ NPT
11⁄4˝ NPTPLUG ANODE
T&P OPENING
F
1˝ NPT(PVG 01200 OVTA)
30° 45°
ASME PLATE(ON PVG 01200 OVTA)
A
C
D
E
F
F
ANODE
F
INSULATED JACKET
3⁄4˝
DATA PLATEUNDER COVER
B
E
F
F
FINSULATED JACKET
3⁄4˝
B
1˝
ASME PLATE
A
CD
3⁄4˝(REAR)
3⁄4˝(REAR)
3⁄4˝
Storage TanksStandard Jacketed Storage Tanks
For more information on State® contact:State Water Heaters500 Tennessee Waltz Parkway, Ashland City, TN 37015800.365.0024 Toll-free USAwww.statewaterheaters.com
STMSS00307 August 2008R ©2008 State Industries, Inc.
PVG 0080 0OVT - JacketedVertical Only
PVG 0120 0OVT - JacketedVertical Only
PVG 0080 0OVTA125
PVG 0120 0OVTA125
PVG 0200 0OVTA125
80 63-1/2 25-1/2 2361.74
119 62 29-1/2 3203.00
80 50-1/2 25-1/4 369-
120 63-1/4 28 411-
175 77 32 560-
Model # Gal Cap A Dim B Dim Weight
PVG 0120 0OVT - Jacketed Vertical OnlyPVG 0080 0OVTA125PVG 0120 0OVTA125PVG 0200 0OVSA125
62
501⁄2
631⁄2
631⁄477
291⁄2
251⁄4
251⁄2
41⁄8
103⁄4 423⁄4
441⁄2
54
35⁄8
553⁄4631⁄2
441⁄ 2
42
2832
16
1112
6 7⁄86
6 7⁄8
9 3⁄4 2 —
21⁄2 —
2
2
80
119
80120175 Yes
YesYes
No
No 150
150
150150150
236
320
369411560
1
3
245
193579_STMSS00307.indd 2193579_STMSS00307.indd 2 8/18/08 11:40:16 AM8/18/08 11:40:16 AM