Standard RF ServicesTelecommunications Division of ©Praetorian Services Pty Ltd
RF Services Portfolio v1.13 Release 19/09/2019
MMIXX
PROPERTY OF ©PRAETORIAN SERVICES PTY LTD. DO NOT REPRODUCE, COPY, EDIT THIS DOCUMENT IN ANY WAY WITHOUT PERMISSION
2
About Us
©Praetorian Communications specialises in
Telecommunications design, build, integration, troubleshooting,
maintenance and site audit activities. We are experienced in
Minor and Major upgrade, Small Cell, IBC, Greenfield and
Brownfield Macro, Repeater and COW solutions.
The following is our standard RF Services which can be tailored
to your customer requirements. We offer competitive pricing
and industry leading quality ensuring first time right success.
We are experienced across all major Telcos, having serviced
Vodafone, Optus and Telstra for all their design requirements.
Our RF Designers have heavy SAED knowledge and experience
which delivers a higher quality output. This is achieved by
understanding the planning restrictions, POI’s, buildability and
more based on years of experience in Network Delivery.
Contents Page
3
RF Portfolio - ContentsAbout Us 2
I. SDB Site Design Brief 4
II. DCS Desktop Candidate Survey 5
III. SSV Site Scoping Visit 6
IV. CAR Candidate Assessment Ranking 7
V. FR RF Feasibility Report 8
VI. RFPDD Preliminary Detailed Design 9
VII. SDV Site Design Visit 10
VIII. STAD STAD 11
IX. ACMA ACMA Compliance 12
X. FA Form A 13
XI. FB Form B 14
XII. RFDD RF Engineering Build Pack 15
XIII. RFSA RF Site Audit 16
XIV. WTDT Walk Test Drive Test 17
Contact Us 18
4
I-SDB Site Design Brief
Define RF KPI Requirements
• Establish required RF Threshold level within a target
coverage polygon
• Primary & Secondary objectives
• RF site capacity Design Requirements
Requirements
• Operator high level RAN design (IE Antenna Config and
Technologies being deployed)
• Optional: Specific areas to cover. Special events, TIO,
known problem areas
• Optional: Existing Neighbouring Site information (Format;
Google Earth/Mapinfo/Excel/Site List)
• Optional: Capacity Report of surrounding sites
Contents Page
5
II-DCS Desktop Candidate Survey RF Preliminary Candidate Scoring
• Our desktop survey scores potential candidates remotely
based on each RF performance criteria comprised of
ACL, Azimuths, Clutter, Terrain Elevations, Lat/Longs,
EME risks, proximity to existing sites and likely RF
Design
• Includes Google Earth PD mark-ups on proposed
candidate locations
Requirements
• Candidates, RF HLD Ran Design, Achievable ACL.
• Optional: Surrounding Network Sites if available.
Contents Page
6
III-SSV Site Scoping Visit
Site Scoping Survey
• Identifies High Level RF Design feasibility including EME
POI's, existing surrounding clutter, proposed azimuths,
ACL heights for clear LoS to target areas
• Profile area to identify any high traffic area(s) of interest
IE Residential, Commercial, Highway, Train Line, Special
Event venues/locations.
• Drone survey in allowable fly zones.
Requirements
• II-DCS
• Preferred: Access to site
Contents Page
7
IV-CAR
Candidate Assessment Ranking Candidate Assessment Scoring
• Provides RF Simulation plots and scoring based off of
achievable ACL, Proposed Azimuths, E/M Tilts, HL RF
design,
• Penalize candidates for higher EME risks, dense
surrounding clutter, step back from Target RF Design
• Reward candidates that can provide balanced capacity
distribution
Requirements
• III-SSV
• Panoramic Site Visit photos of proposed antenna locations
• Preferred/Optional: Access to Carrier Simulation Tool
• Optional: Capacity Congestion Data related to neighbouring
sites
Contents Page
8
V-FR RF Feasibility Report
Proposed RF Design on Primed Candidate
Includes;
• RF Objectives Summary
• EME Risk Assessment
• RF Antenna System Design (Plumbing)
• RF HLD (ACL, Azimuths, E/M Tilts)
Requirements
• IV-CAR
• I-SDB
• Preferred Material List – RAN and Passive
Contents Page
9
VI-RFPDD
Preliminary Detailed DesignLow Level RF Design Detail
Includes:
• Site RF HLND
• RF component models
• Interconnection diagram
• BTS Config Layout
• BOM
Requirements
• V-FR
• Preliminary EBP Template
• Preferred Material List – Passive and Active components
• Spec Sheets for components
Contents Page
10
VII-SDV Site Design Visit
RF Design Visit
• Confirmation of Antenna system placement per
sector, clutter clearance, EME Risk Assessment
including measurement of distances to adjoining
properties and POIs
• Identifying any EME mitigation options if available
• Drone Survey if in permitted Fly zone
• Confirmation on feeder/hybrid runs and placement
of ODU/Shelter as applicable
Requirements
• VI-RFPDD
• Access to site
Contents Page
11
VIII-STAD Proposed STAD
RFNSA STAD Update
• RFNSA Site ID and structure creation
• Proposal of RFNSA STADs
Requirements
• V-FR
• Power Settings for Technologies
• RF NSA Write Access for Carrier
Contents Page
12
IX-ACMA ACMA Compliance
ARPANSA Compliance Report
• Photo pack showing ACMA compliance
• Environmental EME Report
Requirements
• VIII-STAD
Contents Page
13
X-FA Form A
Form A
• Form A is a preliminary EME review, checking whether
MCF guideline has passed
• Required when site is suspected of being in breach of MCF
guideline or where customer requires as part of deliverable
• Highlights what and where the potential MCF guideline
breach is and grades the EME risk
Requirements
• VIII-SDV
• Site Photos
• PD or NFC drawings
Contents Page
14
XI-FB Form B
Form B
• Conducted upon Form A review where MCF
guidelines are in breach. Form B proposes the
necessary EME mitigation strategy required to be
implemented on site for EME compliance
Requirements
• VIII-SDV
• Site Photos
• PRD
• PD or NFC drawings
Contents Page
15
XII-RFDD
RF Engineering Build Pack Low Level RF Design - Final
Includes updates on all:
• Site RF HLND
• RF component models
• Interconnection diagram
• BTS Config Layout
• BOM
Requirements
• FC
• Final EBP Template
• Spec Sheets for components
• Preferred Material List – Passive and Active components
Contents Page
16
XIII-RFSA RF Site Audit As-built RF Audit
• Physical audit verifying as-built redline
matches physical install, including
heights, azimuths, tilts and component
models
• Workmanship audit on RF components
and installation
• EME Audit verifying any Form B’s are
implemented
Requirements
• XII-RFDD
• Access
• FC Redline
• Build Scope
• Form A/B or PRD
Contents Page
17
XIV-WTDT Walk Test Drive TestWalk Test
• Our Walk tests are conducted via Smart Handheld Devices
with RF signal recording software to enable our engineers
to trace the RF environment experienced by handheld
users. These walk tests can be conducted in any indoor or
outdoor environments such shopping malls, office spaces,
warehouses, Stadiums, even on trainlines.
Contents Page
Drive Test
• Whereas our drive tests focus primarily in fast
fading outdoor environments where traffic mobility
is important. The drive data captured by our
scanners and smart handheld devices also allow us
to identify what cell towers are serving your users
and which sites are faulty or underperforming.
18
Contact Us
©Praetorian Services Pty Ltd
©Praetorian Communications
www.praetorianservices.com.au
ACN: 633 855 704
ABN: 28 633 855 704
(02) 8377 7555
Sales Enquiries
Information Enquiries
Contents Page
“Protecting your Investment”