Page 1 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
GOVERNMENT OF INDIA (MINISTRY OF RAILWAYS)
POWER SUPPLY & EMU DIRECTORATE
RESEARCH DESIGNS AND STANDARDS ORGANISATION MANAK NAGAR LUCKNOW – 226011
SPECIFICATION
OF
CCTV SURVEILLANCE AND TALK BACK SYSTEM
FOR EXISTING EMUs, MEMUs AND KOLKATA METRO RAKES
S.No. Month / Year of issue
Revision / Amendment
Page No.
Reason for Amendment
1 March’ 2018 Draft -- First Issue
2 June’2018 Final Draft -- --
SPECIFICATION No. RDSO/PE/SPEC/EMU/0191 (Final Draft) – June’ 2018
APPROVED BY
ED (PS & EMU)
Page 2 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
CONTENTS
Clause No.
DESCRIPTION Page No.
1.0 SCOPE 4 2.0 SYSTEM DESCRIPTION 4 3.0 SCOPE OF SUPPLY 5 4.0 ENVIRONMENTAL CONDITIONS 6 5.0 GENERAL DESIGN REUIREMENTS 7 6.0 TECHNICAL REQUIREMENTS 10 7.0 SOFTWARE REQUIREMENTS 14 8.0 INSPECTION AND TESTING 15 9.0 TRAINING 19
10.0 MARKING 20
Page 3 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
ABBREVIATION USED:
Abbreviation Detail
AGC Automatic Gain Control
BNC Bayonet Nut Connector or British Naval Connector
BLC Back Light Compensation
CCTV Close Circuit Television
CBR Constant Bit Rate
DM(Cars) Driving Motor Coaches
EMI Electromagnetic Interference
EMC Electromagnetic Compatibility
EN European Standards
ETB Emergency Talk Back Unit
FIFO First in, First out
FTP File Transfer Protocol
HMI Human Machine Interface
IP Internet Protocol
IR Infrared Radiation
MVB Multi Vehicle Bus
NVR Network Video Recorder
PoE Power Over Ethernet
SPAD Signal Passing At Danger
SMTP Simple Mail Transfer Protocol
SSD Solid State Drive
VBR Variable Bit Rate
WDR Wide Dynamic Range
WTB Wire Train Bus
Page 4 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
SPECIFICATION OF CCTV SURVEILLANCE AND TALK BACK SYSTEM FOR EXISTING EMUs, MEMUs AND KOLKATA METRO RAKES:
1.0 SCOPE:
This specification covers technical & functional requirements of Closed Circuit Television (CCTV) Surveillance and Emergency Talk Back system intended to be installed in existing EMU,MEMU and Kolkata Metro rakes.
2.0 SYSTEM DESCRIPTION: 2.1 System shall broadly consist of IP Dome saloon cameras, front and rear view platform
camera, Network Video Recorder, HMI Screen in Cabs, Talk Back Unit and
Interconnecting data and power cables along with inter vehicle connectors/couplers
complete for effective & meaningful surveillance.
2.2 Each coach shall be provided at least five (5) cameras devices at appropriate locations
to cover the complete area inside the coach(saloon) for effective surveillance. However
it shall be possible to provide additional two number of cameras by simple plug in to the
system after gaining field experience in future. Each driving cab shall be provided with
one surveillance camera with built-in MIC.
2.3 Each basic unit of the rake (consisting of 3 or 4 coaches) shall be provided with two
Network Video Recorder(NVRs) and each NVR will cater to about 50% cameras of all
the coaches of the basic unit for storing video images so that in case of failure of any of
the NVR, partial recording shall continue in all the coaches with the healthy NVR. In
such case the system shall generate a fault signal identifying the faulty NVR.
2.4 The Video data stored in the Network Video Recorder Unit shall be downloaded at the
EMU Car Shed/Metro depot or any intermediate station specified by the purchaser by
nominated staff through laptop/ exchange removable SSD drive.
2.5 Each coach shall be provided with minimum 4 talk back units, in case there are no
partitions with in the coach. In case of partitions, minimum 2 ETB unit per partition shall
be provided. In case of activation of talk back unit in any of the coach, the views from
camera provided near the location of activated talk back unit shall be displayed in the
HMI screen in the cabs. Moreover, the Driver/Guard shall also be able to select any
other camera, if required.
2.6 Additional camera shall be placed on outer side of the DM car(s) for gathering view of
platforms. The system display shall automatically switch to view of platform when the
train stops and will go back to default mode (saloon view) after the train leaves the
platform. Quantities of platform view cameras 2 nos. in leading and trailing motor
coaches (one each on either side) and 4 nos. in middle motor coaches (2 cameras on
either side).
Page 5 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
2.7 A front view camera shall be provided in front of both the driver cabs behind look out
glass to store the aspect of signal which will be useful in conducing inquiry related to
SPAD.
2.8 Each driver’s cab shall be provided with one HMI screen of size of not less than 10
inches. It shall be so placed in the cab that normally it does not cause distraction to the
driver/guard, but it shall be easy to view it by the driver/guard, if need so arise.
2.9 Provision shall also be made to relay CCTV surveillance recordings to the dedicated
remote server wirelessly through 3G/ 4G/ 5G/Wi-fi or any other mode. The cameras of
running train shall be accessible on real time basis as and when required from remote
server. SIM charges shall be borne by the contractor during warranty period.
2.10 Power supply voltage (nominal) available in the train is 110V dc (it may vary between 77
V dc to 140V dc). This supply shall be made available on one of the endwall panels of
each coach. Extension of this supply to the location of cameras, NVR, HMI screen etc.
will be under the scope of the specification. The contractor shall provide suitable device
to modify/convert this power supply to required voltage level for various devices.
Suitable protection shall be provided in the system in accordance with rolling stock
standards.
3.0 SCOPE OF SUPPLY:
Scope of supply covers design, development, supply, installation and commissioning of complete set of Closed Circuit Television (CCTV) Surveillance and Emergency Talk Back system in existing EMU, MEMU and Kolkata Metro rakes of Indian Railways. System shall broadly comprise of the following:
1. IP Dome Saloon Cameras 2. Front View Cameras 3. Platform View Cameras 4. Driver Cab camera with microphone 5 Network Video Recorder with SSD storage
6 Talk back system
7 HMI Screen in the driving Cabs
8 Managed switch with adequate no. of PoE/non-PoE port
9 Related Software
10 Redundant High speed Gigabit IP backbone( for making ring network) with Inter coach connecting cables, jumpers and connectors
11 Redundant GPS Antenna
12 ETB activated lamps outside on each coach
3.1 MANUFACTURER/CONTRACTOR RESPONSIBILITY:
Page 6 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
The manufacturer/Contractor shall be responsible for the overall design and engineering
of CCTV and talk back system in accordance with the Scope of Supply and Work.
Method of installation and locations of all the equipment including cameras shall be decided by the contractor in consultation with the purchaser, in order to avoid/minimize any mechanical interference with the other equipment of the vehicle. The location and size of the enclosures of equipment shall be decided jointly with the manufacturer/contractor and the purchaser. The manufacturer/contractor shall pre-inspect the rakes for space availability.
3.2 INFRINGEMENT OF PATENT RIGHT:
Indian Railways shall not be responsible for infringement of patent rights arising due to similarity in design, manufacturing process, components used in design, development and manufacturing equipment and any other factor, which may cause such dispute. The responsibility to settle any issue lies with the contractor.
3.3 COMMISSIONING AND FIELD TRIALS:
The commissioning trials shall be done jointly with purchaser for the correct working of
the entire system after installation of complete system on one rake. The contractor has to demonstrate the complete working of the system in a rolling stock during commissioning trials. Supply of equipment/system for other rakes shall be made only after the successful field trial of 2 months on the first rake.
3.4 GOVERNING SPECIFICATIONS
Contractor shall possess and follow the following standards in compliance of this specification:
Standard/ Specification
Description.
IEC 61084 Equipment-Performance standards, Methods of Global Positioning system (GPS)- Receiver
IEC 60571 Electronic equipment used on rail vehicles IEC 61373 Shock and Vibration test IEC 61000 EMI/EMC compatibility test IEC 60529 Degree of protection provided by enclosures(IP code) IEC 60068 Environmental testing IEC 62580 Onboard multimedia and telematic subsystem for Railways – Video
surveillance/CCTV services EN 50121 EMI/EMC tests EN 45545 Fire protection on Railway vehicle EN 50155 Electronic equipment used on rail vehicles
4.0 ENVIRONMENTAL CONDITIOINS The equipment shall function satisfactorily under following conditions.
Page 7 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
Altitude : Up to an altitude of 1200 meters above Mean Sea level
Ambient temperature : -10 to +55C (temperature of stationary rake under sun may go as high as high as 70ºC) - The system shall be designed
accordingly. Relative Humidity : 98%
Ambient Condition : Full of dust, dirt, mist, torrential rain, heavy storms with thunder and lightning likely to generate electrical disturbances, presence of oil vapours and radiant heat etc., to which the rolling stock is normally exposed in service on Indian Railways. EMUs / MEMUs /Kolkata Metro trains also run in saline, salty mist and corrosive atmosphere in coastal areas. The maximum values of related parameters are as under (a) pH value : 8.5 Max. (b) Sulphate : 7 mg/litre (c) Concentration of chlorine : 6 mg/litre Max. (d) Conductivity : 130 micro-siemens/ cm Max. (e) Dust concentration : up to 1.6 mg/m3
4.1 ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY :
i) High degree of electromagnetic interference is expected in the EMU/MEMU/Kolkata metro motor coaches. The surveillance system shall be free from electromagnetic interference as well as interference from communication system between motorman-guard, and control.. The equipment shall be tested as per IEC 60571, EN 50155 & IEC–61000 for EMI & EMC compatibility.
ii) Signals generated by the system / equipment shall not cause interference to other
signal and telecommunication system on the EMUs/MEMUs/Kolkata Metro. 5.0 GENERAL DESIGN REQUIREMENTS:
5.1 NVR, ETB & cameras installed in basic unit shall be provided with unique digital
identification number. This shall be used as key identifier while offloading & analysis video data at shed.
5.2 NVR Unit shall provide encrypted and secured recording for evidence purposes and user authentication to protect data integrity.
5.3 In case of loss of video signal to NVR due to failure of any one or all the cameras for any
reason, there shall be alarm as well as popup blink on the HMI screen in the cab for
respective camera. In case of disconnection/disruption in the transmitting, the NVR shall
be able to resume the video data when network gets connected without any duplication
of video data.
Page 8 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
5.4 NVR shall have the facility to allow downloading of the recording at any intermediate
station by nominated staff through laptop/ exchange removable SSD drive.
5.5 The system i.e cameras and software(video management and video recording) shall be
compliant to global standards ONVIF Profile ‘S’ for the interface of the network video
product(ONVIF- Open Network Video Interface Forum). The quoted model should
appear on the ONVIF website and a confirmation certificate for the offered models to be
provided for the same.
5.6 NVR shall also record the video images captured by front view camera and rear view
platform camera.
5.7 The power supply of the equipment shall be conforming to IEC 60571/EN50155 & IEC 61000 and proven for rolling stock application.
5.8 Complete system viz. Power Supply, NVR Unit and other accessories shall be housed in concealed, powder coated metal enclosure with IP54(minimum) Ingress Protection for dust and water by providing gasket & sealing of cable entry/exit along with lock and key. Lock and key & hinges shall be of Southco/EMKA/Dirak/Jin Tay make.
5.9 All Surveillance Cameras, NVRs and all sub-systems shall be mounted as per sound
engineering practices duly complying with anti-theft & anti-vandalism requirements.
Cameras will be surface mounted whereas ETB shall be flush mounted on the wall of the
coach.
5.10 System shall facilitate clear face recognition for unambiguous identification of the target
person by giving high resolution images. Facial Recognition shall be in low light
condition.
5.11 The system should be based on open environment/protocol like Ethernet for ensuring
inter-changeability of cameras or system shall support at least 3 makes of cameras for
interchangeability of the cameras in complete rake. Contractor shall declare such makes
of cameras.
5.12 The system shall have self-diagnostics features and communicate the same suitably to
the driver/guard.
5.13 deleted.
5.14 deleted.
5.15 deleted.
5.16 Under normal operation, the images captured by each of the camera located in the
coaches shall be sequentially played in the HMI screens of both the driving cabs (driver
Page 9 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
& guard). Adequate controls shall be provided for necessary surveillance requirements
and priorities.
5.17 The visual images from each camera shall be recorded in non volatile memory in a video
recorder without any limitation of repetitive writing of the data. The record shall be easily
downloadable.
5.18 deleted.
5.19 When the talk back unit is operated, a warning audio alarm shall sound in the
driver/guard cab and or indication shall be given to the guard of the location of the
operated device. There shall be provision of lamp outside the coaches to indicate the
location of ETB activation.
5.20 Views from surveillance cameras provided near the location of activated Talk Back
System shall be automatically displayed in the HMI screen in the driver/guard cab.
Thereafter bi-directional audio video communication will be established between
driver/guard and passenger.
5.21 Power cables used in the coach for CCTV surveillance system shall meet RDSO
specification ELRS/SPEC/ELEC/0019 Rev 3 or latest.
5.22 The contractor shall be fully responsible for supplying and laying of all the concealed
cables for communication, electrical connection along with their connectors conforming
to various standards of rolling stock. Cables shall be provided with ferrule marking for
easy identification.
5.23 The contractor shall be fully responsible for integrated testing and commissioning of the
complete CCTV and talk back system.
5.24 The manufacturer shall maintain the sufficient stock of CCTV system aggregates and
enabling Railways to procure the same as per requirements for at least 05 years from
the date of commission of CCTV and talk back system.
5.25 The complete CCTV surveillance system shall conform to IEC 62580.
5.26 The camera shall conform to Impact Rating IK-10 to IEC 62262.
5.27 MTBF (Mean Time Between Failure) for cameras shall be 80,000 hours and for
Recorder shall be 50,000 hours.
5.28 In the complete CCTV surveillance and talk back system, mostly dry type capacitor shall
be used, wherever necessary.
5.29 During installation and commissioning of the system, welding shall be completely
avoided for safety reasons except with the permission of the consignee..
Page 10 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
5.30 After the installation and commissioning of complete CCTV surveillance and talk back
system, all the coaches to be restored to its original condition in terms of electrically,
mechanically and aesthetically.
5.31 It shall be possible to filter, zoom and select images in off line mode for investigation
purpose. The images shall be with time stamping and it shall be possible to link them
with respective location of train.
5.32 The CCTV image quality of surveillance system will be level E as minimum at 100%
Rotakin/Norman measured according to EN 50132-7.
5.33 Commuter awareness instruction/warning stickers to be fixed in all coaches at 5 to 6
locations in three language i.e hindi, English and regional language.
5.34 The system shall be provided with GPS functionality however GPS mapping data
already available with the Railways shall be provided to the manufacturer. If the GPS
mapping has not been done by the Railways then the GPS mapping as a one time
activity shall be done by the contractor/manufacturer.
5.35 The contractor shall submit following documents:
i) Description of CCTV and talk back system along with drawings/schematic diagram.
ii) Relevant certificates and data sheets from OEM conforming to the required standards for the bought out items.
iii) Test certificates issued by reputed International Agencies/NABL accredited lab for Cameras, NVR, Cables and other bought out items as specified in the technical specifications.
iv) Interface plan v) Operation and maintenance manual (soft copy & hard copy @ 1 per
Rake) vi) Spare parts catalogue (soft copy & hard copy @ 1 per Rake) vii) Authorization letter from the OEM for respective units viii) All the integrated test documents, test procedures and check sheets. ix) The Do’s and Dont’s for the system shall be legislated. x) Diagnostics & Maintenance Software. xi) User Manual for Diagnostics & Maintenance Software. xii) Two backup copies of application software. xiii) Test Software
5.36 deleted.
6.0 TECHNICAL REQUIREMENTS
6.1 CCTV SURVEILLANCE SALOON CAMERA:
The camera shall be suitably selected to work in day/night in respect of resolution, clarity
of images and illumination condition for on-train application and shall be of proven
Page 11 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
design. The mounting of camera shall be unobtrusive, flushed with or recessed into the
interior panel and shall conform to suitable IP standard to prevent failures.
The Camera shall conform to the following specification:
Parameter Specification Type IP Dome camera(Vandal proof) Image Sensor 1/2.7” to 1/3” C-MOS or better Lens As per coverage area
Resolution Min.1280 x 720 at 25 FPS or higher Compression H.264, H.265 or better compression Min. Illumination 0.2 lux (Colour) Day & Night Day/Night recording Protocol Suitable and Required network protocol
Back Light Compensation
Yes
White Balance Yes Wide Dynamic Range 120dB Edge storage MicroSD slot supporting memory card for min. 128 GB
Power Supply PoE as per 802.3af with M12/M23 connector or military grade connector
IP Protection IP54
6.2 FRONT VIEW CAMERA
Image Sensor High quality 1/2.7”-1/3” CMOS or better Lens As per coverage area Video H.264 : 25 fps at 1920 x 1080
MPEG4 :25 fps at 1920 x 1080 MJPEG : 25 fps at 1920 x 1080 Compression :H 264, MPGE-4 & MJPEG Streaming: Triple Codac (H.264, MPEG4, JPEG) Selectable
Image settings Adjustable image size, quality Configurable brightness, contrast, saturation, sharpness, while balance and exposure.
Networking Interface 10/100 Mbps Ethernet, M12 Protocol Suitable and Required network protocol
I/O M12 Ethernet Micro SD slot, Default button.
Other feature Sunlight protection, High dynamic range(HDR), protection against cab window glass reflection, protection against rapid changing light conditions, clear image in rain and fog condition
IP Protection IP67
Page 12 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
6.3 PLATFORM VIEW CAMERA
Image Sensor High quality 1/2.7”-1/3” or better CMOS Image Sensor Support 1920 x 1080 at 25 fps
Lens: As per coverage area
Lux Min. 0.2 Lux BLC Auto AGC Auto WDR 120db Can quickly adapt to changes in light Video H.264 : 1920x1080 at 25 fps
Compression :H 264, MJPEG Streaming (or better) (H.264 MPEG4 : JPEG) Selectable Support simultaneous multiple streams
Image settings Adjustable image size & quality Configurable brightness, contrast, saturation, sharpness, while balance and exposure.
Networking Interface 10/100 Mbps Ethernet, M12 Protocol Suitable and Required network protocol
Output IO M12 MicroSD slot supports up to 128 GB
IP Protection IP67 Other feature clear image in rain and fog condition, rear view automatic
swapping
6.4 CABLE and connectors FOR CCTV CAMERA & TALK BACK SYSTEM
The cable and their connectors shall be suitable for use in Rolling Stock. The
specification of Cable for CCTV camera & talk back system is given below:
Description specification DATA CABLE
CAT 7 or better (100 ohm or latest) for Gigabit IP Backbone application, Cat 5( 120 Ohm or latest) for Intra-coach application Compliant to relevant standard for rolling stock Complaint to IEC 60332-1, 60332-2 & 60332-3 /EN45545 for fire safety
6.5 NETWORK VIDEO RECORDER (NVR)
Page 13 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
The Network Video Recorder (NVR) shall be of rugged design with high resistance to
vibration and impact dust-resistant in a metal enclosure. The Network Video Recorder
(NVR) shall conform to the following specification:
Parameter Requirement Video Shall Support minimum 16 cameras Recording Playback
Shall Support Real time video recording & Playback
Storage Each basic unit shall be provided with two NVR in which each NVR will share 50% cameras of the basic Unit. Each NVR shall have one SSD with minimum capacity of 2 TB to record maximum resolution videos for
15 days minimum @24 hours per day. However, event based data shall
be recorded for the longer duration i.e 30 days. Each NVR will cater to about 50% cameras of all the coaches of the basic unit for storing video images so that in case of failure of any of the NVR, partial recording shall continue in all the coaches with the healthy NVR. In such case the system shall generate a fault signal identifying the faulty NVR.
Interface 1)Power input 2)Network interface 3) M12/M23 connector or military grade connectors 4)USB Port 5)Serial Interface, I/O Terminal 6)GPS/3G/4G/LTE/Wi-fi communication
Throughput at least 80 Mbps Protection SSD in a box with lock Operating method
via software in laptop
Anti-Vibration
shock & Vibration conform to IEC 61373
IP protection
IP54
Other feature
Control shall be from any point in the network via laptop
6.6 HMI SCREEN IN THE CAB
Each driver’s cab shall be provided with one touch screen HMI screen of size not less
than 10 inches. The HMI screen shall be large enough to accommodate with acceptable
clarity the simultaneous view of up to four (selectable) front view/rear view/saloon
cameras. Under normal operation, the views gathered from each of the camera located
in the train shall be sequentially played in the monitor screens of both the cabs.
Adequate controls shall be provided for necessary surveillance requirements and
priorities. HMI shall be IP 54 protected.
Page 14 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
6.7 TALK BACK UNIT
Talk back unit allows the passengers to initiate a call request to the Guard in case of an
emergency. Guard shall manage the call through Talk back console provided on the
driver/guard cab. The call starts upon acceptance by the Guard and terminated as per
Guard’s choice. The system offers a complete call queue management on FIFO basis.
On multiple call requests the guard can scroll through the list of calls and answer the one
he deems most urgent. The Talk back unit has provision for activating the indication
lamps fitted outside the coach for indicating activation of talk back unit in a particular
coach.
Talk back unit shall comply following requirements:
i) Compact Anti-vandal powder coated Stainless Steel enclosure unit for mounting flush on the coach wall.
ii) Inbuilt recessed Emergency Call button. iii) Inbuilt Directional Microphone , speaker and Amplifier. iv) Inbuilt power supply compliant to IEC 60571. v) Communication interface 10/100 mbps. vi) Interface for the audio recording during conversation of talk back vii) full duplex voice communication. viii) In-built relay interlocks for activating Emergency Indicator lamps outside the
coach ix) LCD display x) LED indication xi) Interface for provision of audio recording in ETB console at the driver’s cab.
7.0 SOFTWARE REQUIRMENTS 7.1 Software shall be able to playback recorded video stream.
7.2 One or more video streams can be selected and shown simultaneously in a multiple
display.
7.3 The sequences of interest can be flagged with markings on the time bar. These sequences can then be exported by the software and either written to the analysis PC in a file or copied onto CD-ROM or DVD or USB storage.
7.4 Enlarging the images to emphasize key details shall be possible.
7.5 Software shall have the GPS interface to enable system to get the information regarding Train Location, Speed etc.
7.6 In case of operation of Talk back system, video streaming should be automatically activated in Guard/Motorman cab screen.
Page 15 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
7.7 The Software shall support continuous image recording, activity control recording, motion detection recording and Alarm and Trigger input recording etc.
7.8 In case NVR unit operation is interrupted, like power disconnection, the NVR unit shall automatically resume recording of cameras on restoration of power.
7.9 The system software shall support network fault-tolerant recording such that if the network connection between Video Recorder Unit and Camera is unavailable, the Video Recorder Unit shall automatically recover when the connection is restored.
7.10 The system software shall support selective recording search by camera, date and time, events etc. and support export of selected video clips of desired duration to laptop.
7.11 The system software shall maintain system log such as alarms, events and operator log and any other information considered necessary to record.
7.12 The system software shall support user management such as authentication of user login, configuration of users and user access rights.
7.13 The contractor shall provide the required software for accessing the audio-video feed from a remote location through GSM/wi-fi connection. The software should be accessed only by the authorized personnel through login-id and password. The software based on non-proprietary open architecture where it can work and integrate with any make of IT hardware.
7.14 deleted
8.0 INSPECTION AND TESTING: 8.1 TYPE TEST 8.1.1 Only after the detailed drawings and the design have been approved and the clearance
given to this effect, the contractor shall take up the manufacture of the prototype. It is to be clearly understood that any changes, required to be done in the prototype or any additional tests other than specified herein are required to be conducted on the prototype unit or its components, they shall be done expeditiously. During the process of manufacture of the equipment, if the purchaser so desires, he may conduct/repeat any of the routine or additional tests to satisfy himself that the quality of the module being manufactured is of the required standards.
8.1.2 Subject to agreement between user and contractor, RDSO/purchaser shall repeat some
or all type tests once in three years on sample basis, so as to confirm the quality of the product to meet the specified requirements.
8.1.3 The type tests shall be carried out by RDSO representative on prototype unit either
totally or in part under the following conditions without any additional cost:
A manufacturer undertakes to manufacture for the first time.
An important change in design details of machines has been introduced.
Page 16 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
Specification is modified necessitating re-designing of equipment.
Unsatisfactory performance reported from user Railways.
Resumption of production after an interruption of more than two years. 8.1.4 One no. of each item i.e. IP dome Camera, front view camera, rear view platform
camera, HMI screen in cab and Network video recorder(NVR), Talk back unit, Talk back unit console in the cab, shall be subjected to Type Test. The contractor/manufacturer shall submit relevant certificates from OEM conforming to required standards for the bought out items viz. SSD drive, cameras, GPS antenna, HMI, Ethernet switches, cable/connectors etc.
8.1.5 Investigation tests are intended to obtain additional information regarding the performance of the product. They shall be specially requested either by the RDSO or by the purchaser and shall be done at no extra cost.
8.1.6 RDSO may conduct surprise check on manufacturing process and quality control along
with any of the tests to ensure quality of product and its conformance to RDSO specification.
8.1.7 After prototype test and commissioning trials, the system shall be put on field trial for 2
months before final approval and clearance for series supply is granted. 8.1.8 The tests shall be carried out at the works of the contractor/OEM or a reputed testing
laboratory in presence of Indian Railway representative on the prototype unit of the CCTV and talk back system as per relevant governing specifications . The contractor shall have all possible necessary arrangement for testing of complete system.
8.1.9 The test protocol indicating relevant clause of the specification/standard, condition of the
test, specified value and observed value of the parameter for CCTV and talk back system shall be submitted by the firm before offering the sample for testing.
8.1.10 The system shall successfully pass all the type tests for proving conformity with this
specification. If any one of the equipment fails in any of the type tests, the type testing agency at his discretion, may call for another equipment/card(s) of the same type and subject it to all tests or the test(s) in which failure occurred. No failure shall be permitted in the repeat test(s). The prototype set of equipment/assemblies shall be used for commissioning trials on one of the rake. Final clearance shall be given by RDSO after successful completion of above trials.
8.2 ROUTINE TEST 8.2.1 Routine tests are to be carried out on each unit to verify that properties & design of the
product correspond to those measured during type test. Proper documentation of routine test results shall be available with the firm and shall be produced before inspecting official on demand.
8.3 ACCEPTANCE TEST 8.3.1 Each offered lot of supply shall be subjected to acceptance tests as per RDSO approved
sampling plan or as per sampling plan specified in IS 2501, at manufacturer’s works.
Page 17 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
Acceptance test shall be witnessed by inspecting official nominated by purchaser/RDSO. Manufacturer on demand by inspecting official shall produce the internal/routine test report carried out by manufacturer.
8.4 SCHEDULE OF TESTS: schedule of tests to be conducted is as below:
S.No
Description of test Clause No. Type test Acceptance test
Routine test
1 Visual check
As per clause 8.5.1 of this specification
Yes Yes Yes
2 Performance and Function test
As per clause 8.5.2 of this specification
Yes Yes Yes
3 Reverse Polarity test
As per clause-8.5.3 of this specification
Yes Yes Yes
4 Software burn in test A per clause--8.5.4 of this specification
Yes Yes No
5 5
Burn-in(stress screening) test
A per clause-8.5.5 of this specification
Yes No No
6
Electromagnetic compatibility Test.
A per clause-8.5.6 of this specification
Yes No No
7
Enclosure Test
A per clause--8.5.7 of this specification
Yes No No
8
Vibration and Shock test
A per clause--8.5.8 of this specification
Yes No No
9
Bill of Material Test A per clause--8.5.9 of this specification
Yes Yes Yes
10
Endurance test A per clause--8.5.10 of this specification
Yes No No
1 Insulation test As per IEC 60571 Yes Yes Yes
12
Dry heat test
As per IEC 60571 Yes No No
13
Damp heat test
As per IEC 60571 Yes No No
14
Salt mist test for 48 hours
As per IEC 60571 Yes No No
Page 18 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
15
Supply over voltage test
As per IEC 60571 Yes No No
16
Supply Interruption test
As per IEC 60571 Yes No No
8.5 TEST DESCRIPTION: 8.5.1 VISUAL CHECK: During visual check general workmanship, connector, cable and
wiring shall be checked. Dimensions shall be as per approved drawing. Powder coating thickness shall be minimum 60 micron.
8.5.2 PERFORMANCE & FUNCTION TEST: 8.5.2.1 The input current, visibility of display, power consumption, etc. shall be recorded at
input voltage of 77 V dc, 110V dc and 140 V dc. 8.5.2.2 The test set up shall consist of a PC based testing jig for performance integration
testing at contractor premises.. 8.5.2.3 During the performance test conducted as a part of the system shall be connected to
the PC based testing bench and a comprehensive check shall be made during type testing for verifying the functions as per clause 5.0, 6.0, 7.0 and sub-clauses thereof.
8.5.2.4 Data retention of the system shall be checked by interrupting the power supply and
resuming system function. There should be no corruption or loss of data after power interruption.
8.5.2.5 During Routine and Acceptance performance test, the system performance shall be
verified.
8.5.2.6 Function shall be checked as per the specification requirement.
8.5.3 REVERSE POLARITY TEST:
The unit should have built-in reverse polarity protection. The equipment shall function normal after the reverse polarity at input terminals is removed. The reverse polarity shall be tested for at least 1 minute within specified voltage range.
8.5.4 SOFTWARE BURN-IN TEST:
Correct burn-in of embedded software version shall be verified for each unit. 8.5.5 BURN-IN (STRESS SCREENING) TEST:
Burn-in test shall be done on populated PCB in accordance with RDSO specification ELRS/SPEC/SI/0015.
8.5.6 ELECTROMAGNETIC COMPATIBILITY TEST:
Page 19 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
The CCTV and talk back system shall be designed such that there will not be any Electromagnetic Interference and the test shall be conducted for EMI/EMC with relevant clauses of IEC 61000 as under:-
i) Electrical Fast Transient/Burst immunity test The test shall be carried out as per IEC :61000-4-4
Power lines Communication and signal lines
Pulse repetition rate
2.5 KHz 5 KHz
Voltage peak 4 KV 2 KV ii) Surge Test
The test shall be carried out as per IEC:61000-4-5. Installation class:4. Test level : 4 KV
iii) Electrostatic discharge: The test shall be carried out as per IEC-61000-4-2
a) Enclosure conductive part-contact discharge test at 6 KV b) Enclosure insulated part-air discharge test at 8 KV
iv) Radiated susceptibility test : As per IEC-61000-4-3 8.5.7 ENCLOSURE TEST:
This test shall be done for IP67 for Front/Platform view Camera, IP54 for Saloon camera, HMI and NVR (As per IEC 60529).
8.5.8 VIBRATION AND SHOCK TEST:
The Equipment shall be subjected to vibration, shock and simulated long life testing as per IEC 61373 latest version.
Random vibration test as per clause 8 Table 1 , category 1 ,Class B
Simulated long life and random vibration test as per clause 9, Table 2 , category 1, Class B
Shock test as per clause 10, Table 3 , category 1 Class B
8.5.9 Inspecting authority shall check the bill of material of offered sample with the design document and QAP.
8.5.10 ENDURANCE TEST:
Endurance test shall be conducted on one complete system for continuous operation which shall be 72 hrs at ambient room temperature without giving any deterioration of equipment performance.
9.0 TRAINING:
The contractor shall provide free of cost training to Railway personnel/staff of Users Railways in the operation and maintenance of CCTV and talk back system and
Page 20 of 20 RDSO/PE/SPEC/EMU/0191 (Final Draft) June, 2018
Prepared By
(SSE/PS & EMU)
Checked By
(DSE/Conv. EMU System Design)
software. One day training for three persons per depot/workshop is to be arranged by the manufacturer in the field of maintenance and trouble shooting to the Railway staff which shall include complete assembly of the system through the use of various modules, integration of hardware, loading of software and complete operation of the system. The manufacturer shall furnish the syllabus and schedule of training programme to RDSO as part of design proposal. Suitable training material will also be supplied to the participants.
10.0 MARKING: 10.1 All the individual units shall be provided with a name/rating plate on the enclosure. 10.2 The name/identification plates shall be of bright anodized aluminum with black letters
embossed or etched on white background. These plates shall be fitted by riveting. 10.3 The following information shall be clearly marked at a suitable place on each
equipment: a) Name and Address of the manufacturer. b) Year of the manufacturer. c) Serial number of Equipment d) Specification number e) Software and hardware version f) Schematic diagram of the equipment on the side of the cover.
The first two digits shall indicate the year of manufacture, next two digits month and Next three digits for manufacturing serial number.
10.4 Following description shall be etched / engraved / laser printed etc. on the component side of the PCB:
Component outline in the proximity of the component;
Manufacturer’s name.
PCB name.
Part number.
The manufacturing serial number.
Month and year of manufacture