Upload
others
View
8
Download
0
Embed Size (px)
Citation preview
Advanced MPPT Technology
Intelligent selection modes for High/Medium/Low
Power Cut Areas
Advanced DSP based Technology
Pure sine wave output
Temperature compensated charging
(ATC)
Built in energy meter
Highest efficiency in its class
Remote monitoring & data logging
Intelligent Mixing of Grid Current with Solar in case of Solar Energy Shortfall
LCD screen for user convenience
LCD
SOLAR OFF-GRID MPPT PCU ESM3K/48, ESM5K/96, ESM7K5/120, ESM10K/120
www.eastmangroup.co.in | www.eaplworld.com
THE CONTENT
01ABOUT US
02CORE PRODUCT FEATURES
033KVA SOLAR MPPT PCU
045KVA SOLAR MPPT PCU
08FAQ
0610KVA SOLAR MPPT PCU
07OPERATING MODES
057.5KVA SOLAR MPPT PCU
ABOUT US
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
01
, Ver.
1.0
The Eastman Global group began its journey in the year 1970
with presence in over 105 countries and a 2200+ loyal
distributor and dealer network across the world. Eastman Auto
& Power Limited instituted by Eastman group is a leading
manufacturer of Tall Tubular Batteries, Tubular Gel SMF
Batteries, Solar Batteries, E-Rickshaw Batteries & Automotive
Batteries, and offers a wide range of inverters, solar panels and
top of the line solar products that are widely known for their
innovative technology.
Established in1970
2000 CroreTurnover
2500+ HappyEmployees
Presence in 105Countries
OUR ACHIEVEMENTS
CORE PRODUCTFEATURES
1
2
3
4
5
6
7
8
Advanced MPPT Technology
Intelligent selection modes for High/Medium/Low
Power Cut Areas
Advanced DSP basedTechnology
Pure sine wave output
Built in energy meter
Highest efficiency in its class
Intelligent mixing of Grid current with solar in case of solar energy
shortfall during cloudy days
LCD screen for user convenience with
Configurable ParametersLCD
9Temperature compensated charging
Remote monitoring & data logging
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
02
, Ver.
1.0
10
3KVA SOLAR MPPT PCU
Eastman's advanced MPPT technology based 3KVA Solar Off-Grid PCU
has been manufactured in India using world class technology platform
and processes. It is a single integrated system with an inbuilt solar
charge controller, inverter and grid charger. This 3KVA unique hybrid
system provides intelligent mixing of grid current with solar in case of
solar energy shortfall during cloudy days for maximum solar utilization.
The advanced MPPT technology extracts maximum power from the
solar panel array giving highest tracking efficiency of >98%. Eastman's
3KVA Solar MPPT based PCU is best suited for residential homes and
small commercial establishments.
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
03
, Ver.
1.0
Advanced MPPT technology ensures upto 30%more energy extraction from Solar panel ascompared to PWM based technology
Hybrid/PCU/Smart selection mode for high/medium/low power cut areas
Pure sine-wave output
Advanced DSP based technology
LCD Screen for user convenience
User configurable parameters through front end wide screen LCD display
Faster change over time to run IT appliances without interruption
Grid bypass switch for running connected load in case of system failure
Extra safety protections through MCB/fuse
Intelligent mixing of Grid current with solar in case of solar energy shortfall during cloudy days
Highest efficiency in its class
Built-in energy meter for Mains, Battery, Solar andLoad
Temperature compensated (ATC) charging to enhance performance and life of battery upto 30%
USB/Ethernet based data logging with data storage facility
Grid charging Enable/Disable No load shut down Enable/DisableIT Mode Enable/Disable
FEATURES
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
04
, Ver.
1.0
Technical Specifications - 3KVA Solar Off-Grid MPPT PCU
48
43.2±0.4
42±0.4
INPUT PARAMETERS
Nominal I/P DC Voltage (V)
Low Battery Warning (V)
Low Battery Cut off (V)
120% for 60Sec.(3 Retry) & 150%
for 30Sec.(3 Retry) & 200%
for 2Sec.(No Retry)
OUTPUT PARAMETERS
Waveform
Voltage Regulation (From min. to max. battery voltage & no load
to full load) (V)
Frequency Regulation
Peak Efficiency of Inverter
Overload Capacity (Normal Load Selection)
Overload Capacity (IT Load Selection)110% for 60Sec. & 150%
for 30Sec. & 200% for 2Sec.
<3%
3:01
Provided
10 - 15
Pure Sinewave
50 Hz±1Hz
89%
195 - 220
Distortion(THD)
Crest factor
Short Circuit Protection
No load Shutdown (W)
ESM3K/48
3000
MODEL NO.
PCU VA
*Technical Specifications are subject to change without prior notice due to constant improvement in design and technology.
GRID USAGE
Grid Charge End Voltage
Change over Time from Mains to Inverter/Inverter to Mains
Grid I/P Voltage range Default (IT load)
Grid I/P Voltage range Default (Normal load)
Grid Charging Current Default
Charging Current Sharing
Depends on Mode Selection(Solar always on priority)
<10ms
56.8V (Settable from 52-58V)
255V-175V
280V-120V
12A (Settable from 8A-20A)
Provided
Available in Smart Mode
Grid Power usage
Grid Charge Current Enable/Disable
Night Grid Priority
Fan coolingCooling
Solar on priority, in case solar current is less,shortfall will be taken from grid
OTHER SPECIFICATIONS
2KV IP/OP with ground and 1.5KV between input and output
0°C to 50°C
-10°C to 70°C
≤50dB from one meter
95% Non-Condensing
490mm x 260mm x 445mm
45 KG
MPPT SOLAR CHARGE CONTROLLER
Technology
Solar Array
Max Solar Panel Wattage
Input DC Voltage Range (MPPT)
Bulk Voltage
Adjustable Bulk Voltage
Transition from float to bulk
DSP based MPPT charger
Single Array
Power Conversion Efficiency of Solar Charger Controller
Automatic Temperature compensation (Optional)
High Temperature Cut-OFF Inverter/ MPPT
High Temperature MPPT Charge Reconnect
3kWp
72V - 180V
58.4V (Settable from 54V-60V)
User Settable
Below float level
Pv Reverse Protection, Reverse Current Flow, High Temperature, Over Current,
Battery Overcharge Protedction
96%
-3mV/°C/ cell
102°C ± 5°C
85°C ± 5°C
Protection
Battery Voltage, Charging Current, Discharging Current,
Battery Low/High, Battery Charging Unit (kWh) ,
Battery Discharging Unit (kWh), Solar Voltage,
Solar Current, Solar Instantaneous Power,
Solar Commutative Energy Unit (kWh), Grid Voltage,
Grid Current, Grid Commutative Power (kWh),
Grid Instantaneous Power, Grid Frequency, Output Voltage,
Output Current, Cumulative Output Power(kWh),
Output Instantaneous Power, Output Frequency.
LCD Display Messages
System On, Inverter On, Solar Charging On, Grid Charging On,
Battery Low/high, Over Load/Heat, Mains Low/high/freqout,
Fault, MPPT Over Heat.
LED Indications
User Configurable
parameters through front
end LCD display
Battery Low Shutdown, Battery High Cut, Battery Charging
Voltage by Solar, Battery Charging Current by Solar, Battery
Charging Voltage by Grid, Battery Charging Current by Grid,
IT Mode/Normal Mode, Grid Charging Enable/Disable,
Operating Modes (PCU, Smart, Hybrid), No Load Shutdown,
Input Source (Grid/Genset Mode)
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
05
, Ver.
1.0Operating Temp.
Storage Temp.
Acoustic Noise
Relevent Humidity
Size (L x W x H)
Weight (approx.)
Dielectric Strength
*Technical Specifications are subject to change without prior notice due to constant improvement in design and technology.
5KVA SOLAR MPPT PCU
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
06
, Ver.
1.0
Eastman's advanced MPPT technology based 5KVA Solar Off-Grid PCU
has been manufactured in India using world class technology platform
and processes. It is a single integrated system with an inbuilt solar
charge controller and inverter and grid charger. This 5KVA unique
hybrid system adopts intelligent mixing of grid current with solar in case
of solar energy shortfall during cloudy days. The advanced MPPT
technology extracts maximum power from the solar panel array giving
highest tracking efficiency of greater than >98%. Eastman's 5KVA solar
MPPT based PCU is best suited for installing in petrol pumps, gas
stations, schools, commercial and residential applications.
Advanced MPPT technology ensures upto 30%more energy extraction from Solar panel ascompared to PWM based technology
Hybrid/PCU/Smart selection mode for high/medium/low power cut areas
Pure sine-wave output
Advanced DSP based technology
LCD Screen for user convenience
User configurable parameters through front end wide screen LCD display
Faster change over time to run IT appliances without interruption
Grid bypass switch for running connected load in case of system failure
Extra safety protections through MCB/fuse
Intelligent mixing of Grid current with solar in case of solar energy shortfall during cloudy days
Highest efficiency in its class
Built-in energy meter for Mains, Battery, Solar andLoad
Temperature compensated (ATC) charging to enhance performance and life of battery upto 30%
USB/Ethernet based data logging with data storagefacility
DC soft start switch
Grid charging Enable/Disable No load shut down Enable/DisableIT Mode Enable/Disable
FEATURES
ESM5K/96
5000
96
86.4±0.8
84±0.8
120% for 60Sec.(3 Retry) & 150%
for 30Sec.(3 Retry) & 200%
for 2Sec.(No Retry)
<10ms
113.6V (Settable from 104-116V)
255V-175V
280V-120V
12A (Settable from 8A-20A)
Provided
Available in Smart Mode
110% for 60Sec. & 150%
for 30Sec. & 200% for 2Sec.
<3%
3:01
Provided
15 - 20
Pure Sinewave
50 Hz±1Hz
89%
195 - 220
Fan cooling
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
07
, Ver.
1.0
Solar on priority, in case solar current is less,shortfall will be taken from grid
Technical Specifications - 5KVA Solar Off-Grid MPPT PCU
INPUT PARAMETERS
Nominal I/P DC Voltage (V)
Low Battery Warning (V)
Low Battery Cut off (V)
OUTPUT PARAMETERS
Waveform
Voltage Regulation (From min. to max. battery voltage & no load
to full load) (V)
Frequency Regulation
Peak Efficiency of Inverter
Overload Capacity (Normal Load Selection)
Overload Capacity (IT Load Selection)
Distortion(THD)
Crest factor
Short Circuit Protection
No load Shutdown (W)
MODEL NO.
PCU VA
GRID USAGE
Grid Charge End Voltage
Change over Time from Mains to Inverter/Inverter to Mains
Grid I/P Voltage range Default (IT load)
Grid I/P Voltage range Default (Normal load)
Grid Charging Current Default
Charging Current Sharing
Grid Power usage
Grid Charge Current Enable/Disable
Night Grid Priority
Cooling
Depends on Mode Selection(Solar always on priority)
*Technical Specifications are subject to change without prior notice due to constant improvement in design and technology.
DSP based MPPT charger
Single Array
5kWp
144V - 360V
116.8V (Settable from 108V-120V)
User Settable
Below float level
Pv Reverse Protection, Reverse Current Flow, High Temperature, Over Current,
Battery Overcharge Protedction
96%
-3mV/°C/ cell
102°C ± 5°C
85°C ± 5°C
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
08
, Ver.
1.0
Battery Voltage, Charging Current, Discharging Current,
Battery Low/High, Battery Charging Unit (kWh) ,
Battery Discharging Unit (kWh), Solar Voltage,
Solar Current, Solar Instantaneous Power,
Solar Commutative Energy Unit (kWh), Grid Voltage,
Grid Current, Grid Commutative Power (kWh),
Grid Instantaneous Power, Grid Frequency, Output Voltage,
Output Current, Cumulative Output Power(kWh),
Output Instantaneous Power, Output Frequency.
System On, Inverter On, Solar Charging On, Grid Charging On,
Battery Low/high, Over Load/Heat, Mains Low/high/freqout,
Fault, MPPT Over Heat.
Battery Low Shutdown, Battery High Cut, Battery Charging
Voltage by Solar, Battery Charging Current by Solar, Battery
Charging Voltage by Grid, Battery Charging Current by Grid,
IT Mode/Normal Mode, Grid Charging Enable/Disable,
Operating Modes (PCU, Smart, Hybrid), No Load Shutdown,
Input Source (Grid/Genset Mode)
2KV IP/OP with ground and 1.5KV between input and output
0°C to 50°C
-10°C to 70°C
≤50dB from one meter
95% Non-Condensing
647mm x 330mm x 580mm
60 KG
MPPT SOLAR CHARGE CONTROLLER
Technology
Solar Array
Max Solar Panel Wattage
Input DC Voltage Range (MPPT)
Bulk Voltage
Adjustable Bulk Voltage
Transition from float to bulk
Power Conversion Efficiency of Solar Charger Controller
Automatic Temperature compensation (Optional)
High Temperature Cut-OFF Inverter/ MPPT
High Temperature MPPT Charge Reconnect
Protection
OTHER SPECIFICATIONS
LCD Display Messages
LED Indications
User Configurable
parameters through front
end LCD display
Operating Temp.
Storage Temp.
Acoustic Noise
Relevent Humidity
Size (L x W x H)
Weight (approx.)
Dielectric Strength
*Technical Specifications are subject to change without prior notice due to constant improvement in design and technology.
7.5KVA SOLAR MPPT PCU
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
09
, Ver.
1.0
Eastman's Off-Grid MPPT based 7.5KVA Solar PCU has been
manufactured in India using world class technology platform and
processes. Inbuilt with advanced DSP based technology the Solar PCU
series has a rugged, strong and long lasting design. It provides
operational flexibility to its users to enjoy the benefits of advanced
monitoring and control features. The advanced MPPT technology
extracts maximum power from the solar panel array giving highest
tracking efficiency of >98%. It has been designed on intelligent thermal
management system suitable for installing in petrol pumps, gas
stations, schools, commercial and residential applications.
Advanced MPPT technology ensures upto 30%more energy extraction from Solar panel ascompared to PWM based technology
Hybrid/PCU/Smart selection mode for high/medium/low power cut areas
Pure sine-wave output
Advanced DSP based technology
LCD Screen for user convenience
User configurable parameters through front end wide screen LCD display
Faster change over time to run IT appliances without interruption
Grid bypass switch for running connected load in case of system failure
Extra safety protections through MCB/fuse
Intelligent mixing of Grid current with solar in case of solar energy shortfall during cloudy days
Highest efficiency in its class
Built-in energy meter for Mains, Battery, Solar andLoad
Temperature compensated (ATC) charging to enhance performance and life of battery upto 30%
USB/Ethernet based data logging with data storagefacility
DC soft start switch
Grid charging Enable/Disable No load shut down Enable/DisableIT Mode Enable/Disable
FEATURES
ESM7K5/120
7500
120
108±2
105±2
<10ms
142V (Settable from 130-145V)
255V-175V
280V-120V
12A (Settable from 8A-20A)
Provided
Available in Smart Mode
110% for 60Sec. & 150%
for 30Sec. & 200% for 2Sec.
<3%
3:01
Provided
20 - 25
Pure Sinewave
50 Hz±1Hz
89%
195 - 220
Fan cooling
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
10
, Ver.
1.0
120% for 60Sec.(3 Retry) & 150%
for 30Sec.(3 Retry) & 200%
for 2Sec.(No Retry)
Technical Specifications - 7.5KVA Solar Off-Grid MPPT PCU
INPUT PARAMETERS
Nominal I/P DC Voltage (V)
Low Battery Warning (V)
Low Battery Cut off (V)
OUTPUT PARAMETERS
Waveform
Voltage Regulation (From min. to max. battery voltage & no load
to full load) (V)
Frequency Regulation
Peak Efficiency of Inverter
Overload Capacity (Normal Load Selection)
Overload Capacity (IT Load Selection)
Distortion(THD)
Crest factor
Short Circuit Protection
No load Shutdown (W)
MODEL NO.
PCU VA
GRID USAGE
Grid Charge End Voltage
Change over Time from Mains to Inverter/Inverter to Mains
Grid I/P Voltage range Default (IT load)
Grid I/P Voltage range Default (Normal load)
Grid Charging Current Default
Charging Current Sharing
Grid Power usage
Grid Charge Current Enable/Disable
Night Grid Priority
Cooling
Solar on priority, in case solar current is less,shortfall will be taken from grid
Depends on Mode Selection(Solar always on priority)
*Technical Specifications are subject to change without prior notice due to constant improvement in design and technology.
2KV IP/OP with ground and 1.5KV between input and output
0°C to 50°C
-10°C to 70°C
≤50dB from one meter
95% Non-Condensing
647mm x 330mm x 580mm
70 KG
DSP based MPPT charger
Single Array
7.5kWp
180V - 450V
146V (Settable from 135V-150V)
User Settable
Below float level
Pv Reverse Protection, Reverse Current Flow, High Temperature, Over Current,
Battery Overcharge Protedction
-3mV/°C/ cell
102°C ± 5°C
85°C ± 5°C
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
11
, Ver.
1.0
Battery Voltage, Charging Current, Discharging Current,
Battery Low/High, Battery Charging Unit (kWh) ,
Battery Discharging Unit (kWh), Solar Voltage,
Solar Current, Solar Instantaneous Power,
Solar Commutative Energy Unit (kWh), Grid Voltage,
Grid Current, Grid Commutative Power (kWh),
Grid Instantaneous Power, Grid Frequency, Output Voltage,
Output Current, Cumulative Output Power(kWh),
Output Instantaneous Power, Output Frequency.
System On, Inverter On, Solar Charging On, Grid Charging On,
Battery Low/high, Over Load/Heat, Mains Low/high/freqout,
Fault, MPPT Over Heat.
Battery Low Shutdown, Battery High Cut, Battery Charging
Voltage by Solar, Battery Charging Current by Solar, Battery
Charging Voltage by Grid, Battery Charging Current by Grid,
IT Mode/Normal Mode, Grid Charging Enable/Disable,
Operating Modes (PCU, Smart, Hybrid), No Load Shutdown,
Input Source (Grid/Genset Mode)
96%
MPPT SOLAR CHARGE CONTROLLER
Technology
Solar Array
Max Solar Panel Wattage
Input DC Voltage Range (MPPT)
Bulk Voltage
Adjustable Bulk Voltage
Transition from float to bulk
Protection
OTHER SPECIFICATIONS
LCD Display Messages
LED Indications
User Configurable
parameters through front
end LCD display
Operating Temp.
Storage Temp.
Acoustic Noise
Relevent Humidity
Size (L x W x H)
Weight (approx.)
Dielectric Strength
Power Conversion Efficiency of Solar Charger Controller
Automatic Temperature compensation (Optional)
High Temperature Cut-OFF Inverter/ MPPT
High Temperature MPPT Charge Reconnect
*Technical Specifications are subject to change without prior notice due to constant improvement in design and technology.
10KVA SOLAR MPPT PCU
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
12
, Ver.
1.0
Advanced MPPT technology ensures upto 30%more energy extraction from Solar panel ascompared to PWM based technology
Hybrid/PCU/Smart selection mode for high/medium/low power cut areas
Pure sine-wave output
Advanced DSP based technology
LCD Screen for user convenience
User configurable parameters through front end wide screen LCD display
Faster change over time to run IT appliances without interruption
Grid bypass switch for running connected load in case of system failure
Extra safety protections through MCB/fuse
Intelligent mixing of Grid current with solar in case of solar energy shortfall during cloudy days
Highest efficiency in its class
Built-in energy meter for Mains, Battery, Solar andLoad
Temperature compensated (ATC) charging to enhance performance and life of battery upto 30%
USB/Ethernet based data logging with data storagefacility
DC soft start switch
Grid charging Enable/Disable No load shut down Enable/DisableIT Mode Enable/Disable
FEATURES
Eastman's Off-Grid MPPT based 10KVA Solar PCU has been
manufactured in India using world class technology platform and
processes. Inbuilt with advanced DSP based technology the Solar PCU
series has a rugged, strong and long lasting design. It provides
operational flexibility to its users to enjoy the benefits of advanced
monitoring and control features. The advanced MPPT technology
extracts maximum power from the solar panel array giving highest
tracking efficiency of >98%. It has been designed on intelligent thermal
management system suitable for installing in petrol pumps, gas
stations, schools, commercial and residential applications.
ESM10K/120
10000
120
108±2
105±2
<10ms
142V (Settable from 130-145V)
255V-175V
280V-120V
12A (Settable from 8A-20A)
Provided
Available in Smart Mode
110% for 60Sec. & 150%
for 30Sec. & 200% for 2Sec.
<3%
3:01
Provided
25 - 30
Pure Sinewave
50 Hz±1Hz
89%
195 - 220
Fan cooling
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
13
, Ver.
1.0
120% for 60Sec.(3 Retry) & 150%
for 30Sec.(3 Retry) & 200%
for 2Sec.(No Retry)
INPUT PARAMETERS
Nominal I/P DC Voltage (V)
Low Battery Warning (V)
Low Battery Cut off (V)
OUTPUT PARAMETERS
Waveform
Voltage Regulation (From min. to max. battery voltage & no load
to full load) (V)
Frequency Regulation
Peak Efficiency of Inverter
Overload Capacity (Normal Load Selection)
Overload Capacity (IT Load Selection)
Distortion(THD)
Crest factor
Short Circuit Protection
No load Shutdown (W)
MODEL NO.
PCU VA
GRID USAGE
Grid Charge End Voltage
Change over Time from Mains to Inverter/Inverter to Mains
Grid I/P Voltage range Default (IT load)
Grid I/P Voltage range Default (Normal load)
Grid Charging Current Default
Charging Current Sharing
Grid Power usage
Grid Charge Current Enable/Disable
Night Grid Priority
Cooling
Technical Specifications - 10KVA Solar Off-Grid MPPT PCU
Solar on priority, in case solar current is less,shortfall will be taken from grid
Depends on Mode Selection(Solar always on priority)
*Technical Specifications are subject to change without prior notice due to constant improvement in design and technology.
2KV IP/OP with ground and 1.5KV between input and output
0°C to 50°C
-10°C to 70°C
≤50dB from one meter
95% Non-Condensing
660mm x 330mm x 665mm
100 KG
DSP based MPPT charger
Single Array
10kWp
180V - 450V
146V (Settable from 135V-150V)
User Settable
Below float level
Pv Reverse Protection, Reverse Current Flow, High Temperature, Over Current,
Battery Overcharge Protedction
96%
-3mV/°C/ cell
102°C ± 5°C
85°C ± 5°C
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
14
, Ver.
1.0
Battery Voltage, Charging Current, Discharging Current,
Battery Low/High, Battery Charging Unit (kWh) ,
Battery Discharging Unit (kWh), Solar Voltage,
Solar Current, Solar Instantaneous Power,
Solar Commutative Energy Unit (kWh), Grid Voltage,
Grid Current, Grid Commutative Power (kWh),
Grid Instantaneous Power, Grid Frequency, Output Voltage,
Output Current, Cumulative Output Power(kWh),
Output Instantaneous Power, Output Frequency.
System On, Inverter On, Solar Charging On, Grid Charging On,
Battery Low/high, Over Load/Heat, Mains Low/high/freqout,
Fault, MPPT Over Heat.
Battery Low Shutdown, Battery High Cut, Battery Charging
Voltage by Solar, Battery Charging Current by Solar, Battery
Charging Voltage by Grid, Battery Charging Current by Grid,
IT Mode/Normal Mode, Grid Charging Enable/Disable,
Operating Modes (PCU, Smart, Hybrid), No Load Shutdown,
Input Source (Grid/Genset Mode)
MPPT SOLAR CHARGE CONTROLLER
Technology
Solar Array
Max Solar Panel Wattage
Input DC Voltage Range (MPPT)
Bulk Voltage
Adjustable Bulk Voltage
Transition from float to bulk
Protection
Power Conversion Efficiency of Solar Charger Controller
Automatic Temperature compensation (Optional)
High Temperature Cut-OFF Inverter/ MPPT
High Temperature MPPT Charge Reconnect
OTHER SPECIFICATIONS
LCD Display Messages
LED Indications
User Configurable
parameters through front
end LCD display
Operating Temp.
Storage Temp.
Acoustic Noise
Relevent Humidity
Size (L x W x H)
Weight (approx.)
Dielectric Strength
*Technical Specifications are subject to change without prior notice due to constant improvement in design and technology.
OPERATING MODES
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
15
, Ver.
1.0
A. Load Runs on Solar + Battery (If Batt. volt. = 13.5V & 100% Battery
Charging Current (as set by user) from solar or = 14.5V for 2Mins)
B. Load Runs on Grid + Battery Charging By Solar or Grid + Solar
(If Otherwise)
A. Load Runs on Battery (If Batt. volt. >11.5V)
B. Load Runs on Grid + Battery Charging By Grid
(If Otherwise)
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Absent Grid Present
CASE - 02
A. Load Runs on Battery
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Absent Grid Absent
CASE - 03
A. Load Runs on Solar + Battery Charging on Solar (If Solar Power > Load Power)
B. Load Runs on Solar + Battery (If Otherwise)
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Present Grid Absent
CASE - 04
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Present Grid Present
CASE - 01
PCU MODE
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
16
, Ver.
1.0
HYBRID MODE
A. Load Runs on Grid
B. Battery Charging By Solar or Solar + Grid
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Present Grid Present
CASE - 01
A. Load Runs on Grid
B. Battery Charging By Grid
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Absent Grid Present
CASE - 02
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Absent Grid Absent
A. Load Runs on Battery
CASE - 03
A. Load Runs on Solar + Battery Charging on Solar
(If Solar Power > Load Power)
B. Load Runs on Solar + Battery (If Otherwise)
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Present Grid Absent
CASE - 04
SMART MODE
NOTE - Battery charging by grid will only take place if grid charging is enabled.
A. Load Runs on Solar or Solar + Battery (If Batt. volt. = 13.5V &
100% Battery Charging Current (as set by user) from Solar
or 14.5V for 2Mins)
B. Load Runs on Grid + Battery Charging By Solar (If Otherwise)
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Present Grid Present
CASE - 01
A. Load Runs on Grid (If Batt. volt. >11.2V)
B. Load Runs on Grid + Battery Charging Upto 14.2V (If Otherwise)
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Absent Grid Present
CASE - 02
A. Load Runs on Battery
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Absent Grid Absent
CASE - 03
A. Load Runs on Solar + Battery Charging on Solar
(If Solar Power > Load Power)
B. Load Runs on Solar + Battery (If Otherwise)
Grid SupplySolar Power
LoadBatteryBackup
Solar PCU
Solar Present Grid Absent
CASE - 04
FREQUENTLY ASKED QUESTIONS
SO
LAR
OFF
-GR
ID M
PP
T P
CU
, PA
GE
17
, Ver.
1.0
01 What is an Off-Grid Solar System?
An Off-Grid Solar System consists of solar panels, solar inverter, charge controller and batteries. When sun rays fall
on solar panels, DC power is generated. This DC power is then converted into usable AC power to run the connected
appliances. The surplus DC power is stored in batteries to be used during power cuts. The inbuilt solar charge
controller ensures proper battery charging and prevents reverse flow of current to the solar panels.
02 What is Maximum Power Point Tracking?
A maximum power point tracker is a DC to DC converter that optimizes the power conversion between the solar
panels and battery bank or utility grid. The charge controller checks the output of the panels, and compares it to the
battery voltage. It then decides the best power that the panel can put out to charge the battery. The MPPT solar
charge controller then converts it to best voltage to get maximum current into the battery.
03 How is PWM based solar charge controllers different from MPPT based?
There are two types of solar charge controllers– PWM (Pulse Width Modulation) and MPPT (Maximum Power Point
Tracking). The MPPT is a more advanced technology charger than PWM and is meant to extract maximum power
from the solar panel to provide the best charging current to the battery. They convert extra voltage of panel into
current which increases the output current (Im + Difference due to conversion of extra voltage into current) from
the solar system. PWM on the other hand would simply deliver the amount of current equivalent to Im to the battery.
04 How are MPPT based charge controllers better than PWM?
As one can figure out an on-grid solar system is 'always connected to the grid'. There is no provision of battery
storage in an on-grid system. The connected appliances are powered through available solar and unused solar
power is exported to the grid. In an off grid solar system there is a provision of battery backup.
05 How is ATC technology beneficial for me?
ATC means automatic temperature compensation. This technology enables your Off grid PCU to detect the ambient
temperature surrounding the battery. All batteries require 25 degrees room temperature to function optimally. In
case of summers the ambient temperature is high which may lead to overheating and overcharging of the battery. To
maintain battery temperature the ATC sensor adjusts the bulk boost voltage of the battery to ensure optimum
battery charging and enhance battery performance in all weather conditions.
INDIA
CORPORATE OFFICE EASTMAN AUTO & POWER LTD.547, Udyog Vihar, Phase-V, Gurgaon-122016, Haryana, India.India Toll Free No. 1800 419 8610
DUBAI OFFICE AMPS MIDDLE EAST FZE P.O. Box - 56473, Ras Ali Khaimah, United Arab Emirates
+91 124 4682600/2610 | [email protected]