Page 1: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

Software rel. 2.3.x

RPM INDICATOR VERSION

Page 2: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

2

CONTENTS

● Legendofsymbols.....................................................................................................3INTRODUCTION ............................................................................................................4 Productdescription....................................................................................................4INTENDED USE .............................................................................................................4CONTENT OF THE PACKAGE .....................................................................................4PRECAUTIONS .............................................................................................................4RISKS AND PROTECTIONS BEFORE ASSEMBLY ....................................................5 Positioning..................................................................................................................5 Powersupplyandsensorconnection........................................................................5ASSEMBLY DIAGRAMS ...............................................................................................6CONTROLS IN THE MENU ...........................................................................................7 Firstswitchingon.......................................................................................................7 Controlsinthemenu..................................................................................................8MENU STRUCTURE ....................................................................................................10 RPMAlarms............................................................................................................. 11 Sensors....................................................................................................................12 Sensors>Manualcalibration...................................................................................13 Language.................................................................................................................14 Displaycontrast........................................................................................................14 Alarmtones..............................................................................................................15 Keytones..................................................................................................................15 Displaysettings........................................................................................................16 Operatingmode.......................................................................................................17 Setupmanagement..................................................................................................18 Testmenu.................................................................................................................20USE ..............................................................................................................................22 Partialtotalizerreset................................................................................................22MAINTENANCE / DIAGNOSTICS / REPAIRS ............................................................23 Troubleshooting........................................................................................................23END OF LIFE DISPOSAL ............................................................................................23TECHNICAL DATA ......................................................................................................24 Devicetechnicaldata...............................................................................................24 Setupmenu..............................................................................................................25GUARANTEE TERMS .................................................................................................26

Page 3: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

3

● Legendofsymbols

= Genericdanger

= Warning

This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for any future reference; ARAG reserves the right to modify product specifications and instructions at any moment and without notice.

Page 4: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

4

INTRODUCTION

Productdescription

VISIOisaverycompactandaccuratetop-notchmultifunctiondisplay,abletodisplayanykindofinformationconcerningagriculturaltreatments.Operatorcanselecttherequiredfunctionviasoftware.Itcandisplayseveraltypesofvalues,whichchangeaccordingtosetoperatingmodeandtypeofconnectedsensors.

INTENDED USE

This device is designed towork onagriculturalmachinery for spraying and cropsprayingapplications.ThemachineisdesignedandbuiltincompliancewithENISO14982standard(Electromagneticcompatibility-Forestryandfarmingmachines),harmonizedwith2014/30/UEDirective.

CONTENT OF THE PACKAGE

ThetablebelowindicatesthecomponentsthatyouwillfindintheVISIOpackage:

Legend:

1 VISIO2 Fixingkit3 Instructionmanual (onCD-ROM)4 Installationsheet

PRECAUTIONS

•Donotaimwaterjetsattheequipment.•Donotusesolventsorfueltocleanthecaseoutersurface.•Donotcleanequipmentwithdirectwaterjets.•Complywiththespecifiedpowervoltage(12VDC).•Incaseofvoltaicarcwelding,removeconnectorsfromVISIOanddisconnectthepowercables.•OnlyuseARAGgenuinesparepartsandaccessories.

P o w e r c a b l e ,s e n s o r s a n dconnection cablesto be connectedto VISIO must beorderedseparately.

Page 5: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

5

RISKS AND PROTECTIONS BEFORE ASSEMBLY

Allinstallationworksmustbedonewithbatterydisconnected,usingsuitabletoolsandanyindividualprotectionequipmentdeemednecessary.

Positioning

1) Set mounting rail in cabin and fasten it with the relevant screws (1), in a position where VISIO can be easily seen and at hands' reach, but away from any moving organs.2) Secure VISIO to rail and push down until locked in place.3) Fasten wiring so that it does not interfere with any moving parts.

Powersupplyandsensorconnection

Sensorsandpowersupplymustbeinstalledandconnectedbyqualifiedpersonnel.VISIOmustbeexclusivelyconnectedtoARAGequipment.WHENARCWELDINGISREQUIRED,MAKESURETHATEQUIPMENTPOWER IS SWITCHED OFF; DISCONNECT POWER CABLES IF NEEDED.ARAGisnotliablefordamagetothesystem,persons,animalsorpropertycausedbyVISIOwrongorunsuitableassembly.Failuretoobservetheaboveinstructionsautomaticallyvoidsthewarranty.

Wirecolor (powercable) Connectionof

red positive

black negative

green countingabort-groundconnection

yellow countingabort-connection+12VDC

power supplysensors

Page 6: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

6

ASSEMBLY DIAGRAMS

Counting abortGround connection

(green wire)

5

3

4

+12Vdc

GND

Counting abortConnection

+12VDC

(yellow wire)

Legend:

1)Powercable2)Connectioncableforsinglesensor3)Connectioncablefordoublesensor*4)Rpmsensor15)Rpmsensor2**=optional, according to the selected configuration.

Page 7: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

7

CONTROLS IN THE MENU

Firstswitchingon

Atfirstswitchingon,VISIOwillrunaguidedprocedureallowingusertosetthedevice'sbasicsettings.

Press toscrollthroughitems,OKtosaveandmoveontonextsetting,orESCtogobacktoprevioussetting.

WARNING:Beforechangingoperatingmode,makesurethatallsensors/flowmetersareDISCONNECTEDfromthedevice.

Page 8: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

8

Controlsinthemenu

Inthefollowingpages,accordingtothesetoperatingmode,somemenuitemscouldslightlydifferfromtheshownones.

SWITCHING ONAPressfor1secondBPressthekeyafewtimestoviewthevariousvaluesinextendedmode,(ondisplaycentralpart)Everytimethedeviceisswitchedon,itwillshortlyshowapagewiththenameofdeviceandsoftwareversion.

SWITCHING OFFAPressfor2seconds

ACCESS TO SETUP MENUFromthemainpage,presskeysatthesametimefor2secondstoopentheSetupMenu.

Page 9: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

9

SELECTION AND ACCESS TO MENU ITEMS

APressafewtimestoscrollthroughitems(selecteditemisindicatedbyablackline)BPresstoopentheselectedmenuitem

Thethreedotsunderanitemindicatepresenceofanothersetupmenu.

EDITING A VALUE

APresstomovethroughdigitsBPressafewtimestoeditthehighlighteddigitCPresstoconfirm.ThedisplaygoesbacktopreviouspageDPresstoexitpagewithoutconfirmingmodification

Editedvaluemustfallwithintherangeshown.

Page 10: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

10

MENU STRUCTURE

0 rpm1

01

1

MIN

0 rpmMAX

rpm

Alarms

Sens. 1-2 min RpmSens. 1-2 max Rpm

Sensors

Rpm 1Rpm 2

Man. calibration

Options

Language

Data 1Data 2Data 3

Display contrast

Alarm tones

Keytones

Display settings

Rpm sensor 1-2Sens. 1-2 min RpmSens. 1-2 max RpmRpm sens. 1-2 time

}Operating mode

Setup management

Save setupLoad setup

Test

Firmware versionBattery voltageDisplayKeysSensors

Rpm

Page 11: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

11

RPMAlarms

SetthedesiredalarmdisplaythresholdsforminimumandmaximumRpmvalues.

1)OpenAlarmmenu(Setupmenu>Alarms).

MinimumandmaximumRpmalarmsaresetinthesameway.

Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

Thismenuallowssettingtwodifferentsensors(ifavailable).

Incaseonlyonesensorisused,useitemsrelatedtosensor1toperformthecorrectsettings.

2)Toactivatethealarm,press and

atthesametimeuntilmessage OFFgoesoffandtheRpmalarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 12: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

12

Sensors

1)OpenSensorsmenu(Setupmenu>Sensors).

Themenuitemsdisplayedbelowchangeaccordingtothesetoperationmode:whenmoreitemsareavailable,selectthedesiredoneandpressOKtoeditit.

Page 13: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

13

Sensors>Manualcalibration

VISIOprocesses the rotationspeed information related toaspecificpart throughthepulsesfromtheRpmsensor.ThemanualcalibrationallowsenteringtheRpmconstantvalue.

1)OpenSensorsmenu(Setupmenu>Sensors).

2)Presstoopenmanualcalibrationmode.

Thismenuallowssettingtwodifferentsensors(ifavailable).Incaseonlyonesensorisused,useitemsrelatedtoRpm1toperformthesettings.

3)SettheRpmconstantvalue,i.e.thenumberofdetectionpoints,suchasmagnetsorboltsfittedontherotatingshaftwhoserotationspeedshallbedetected:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C) Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 14: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

14

Language

Setthedesiredlanguage.

Alarm tones

Display contrast

Openlanguagesettingmenu(Setupmenu>Options>Language).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectthelanguage.

2 1

2

Language

English

ČeskDeutsch

Español

1)Selectalanguagethrough .

2)PressOKtosave,orESCtoquitwithoutsaving.

Displaycontrast

Setdisplaycontrast.

Options

Language

Alarm tones

Display contrast50%

Opendisplaycontrastmenu(Setupmenu>Options>Displaycontrast).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

1)Setavaluethrough .Everytime

youpressit,valuewillincreaseby5%up

to100%.Use keytodecreasevalue

by5%.2)PressOKtosave,orESCtoquitwithoutsaving.

Page 15: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

15

Alarmtones

Enable/disablethealarmtones.

OpenAlarmtonesmenu(Setupmenu>Options>Alarmtones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

1)Setstatusthrough key.

2)PressOKtosave,orESCtoquitwithoutsaving.

Keytones

Enable/disablekeytones.

1)Openkeytonesmenu(Setupmenu>Options>Keytones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

1)Setstatusthrough .

2)PressOKtosave,orESCtoquitwithoutsaving.

Page 16: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

16

Displaysettings

Themain page shows the display dividedinto three horizontal parts, which can beseparatelyreset(accordingtothevalue).Everysectorcanbeassignedthedesiredvalue:

-Rpmsensor1-2=Rpmlivereading;-Min.Rpmsens.1-2=minimumdetectedRpm;-Max.Rpmsens.1-2=maximumdetectedRpm;-Rpmsens.1-2time=value,measuredinseconds,duringwhichVISIOhasdetectedamovementdifferentfrom0.

OpenDisplaysettingsmenu(Setupmenu>Options>Displaysettings).Press OK toedittheselectedmenuitem.

1)Selectvaluethrough .

2)PressOKtoedit,orESCtoquitwithoutsaving.

1)Setsectortotherequiredvalue

through .

2)PressOKtosave,orESCtoquitwithoutsaving.Carryoutthesameprocedurefortheother2values.

Page 17: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

17

Operatingmode

Setrequiredoperatingmode.

Openoperatingmodemenu(Setupmenu>Options>Operatingmode).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK tochangetheoperatingmode.

1)Selecttherequiredoperatingmode

through .

2)PressOK tosave,orESC toquitwithoutsaving.

WARNING:OnceOKispressed,thepageontwhesidewillbedisplayed.Beforechangingoperatingmode,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmchanges.ConnectthesensorsREQUIREDFORTHE SET OPERATING MODE.

Page 18: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

18

Setupmanagement

VISIOsettingscanbeloadedfromorsavedonaUSBpendriveinordertoreconfigureit ifrequired,fixproblemsorsetanotherVISIOwithnoneedtorepeatallmanualoperations.Onceinstallationiscompleted,andVISIOoperationhasbeenchecked,werecommendtosaveallsettingsontoaUSBpendrive.TobeabletousethefollowingfunctionsitisnecessarytoinsertaUSBpendriveintherelevantportatthebottomofVISIO.

1)OpenSetupmanagementmenu(Setupmenu>Setupmanagement).

PressOK toedittheselectedmenuitem.

Load setupAllowstoselectaconfigurationfilesavedintheUSBpendriveandtosetVISIOagain.WARNING:ByloadingtheSETUP.BIN filecontainedintheUSBpendriveontotheVISIO,allcurrentsettingswillbelost.

1)Selectthedesiredcontrolthrough key.2)PressOK toconfirmloading,orESC toquitwithoutsaving.

TheSETUP.BINfilecanbeloadedonlyifitissavedintheUSBpendriverootdirectory.Ifsetupdownloadinvolveschangingoperatingmodeandusingdifferentsensorsthantheonesinuse,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmloading.Reconnectsensors.

Page 19: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

19

Save setupAllowssavingVISIOconfigurationfileontheUSBpendrive:itwillbepossibletoloaditagainanytimethesamesettingsneedtoberetrieved.

1)Selectthedesiredcontrolthrough

key.2)PressOK toconfirmsaving,orESC toquitwithoutsaving.

IfaSETUP.BINfileisalreadypresentintheUSBpendriverootdirectory,thefilewillbeoverwritten.

Page 20: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

20

Testmenu

ThismenuallowsusertoviewsomedataandcarryoutanoperationtestofVISIO:-Firmwareversion:thedisplayshowsthefirmwareversioninstalled.-Batteryvoltage:thedisplayshowsthepowervoltageofthedevice.

Display test

Displaytestchecksthedevicedisplaycorrectoperation.

1)Opendisplaytestmenu(Setupmenu>Test>Display).Press OK toperformthetest.

Allpixelsondisplayareturnedon.PressESCtogobacktopreviouspage.

Keys test

Keystestchecksthedevicekeyscorrectoperation.

Openkeystestmenu(Setupmenu>Test>Keys).

Press OK toperformthetest.

1)Pressanykeyandthecorrespondingdisplayareawillturnon.PressESC toquit:assoonasyouacknowledgetheswitch-ononofthecorrespondingareaonthedisplay,devicewillgobacktopreviouspage.

Page 21: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

21

Sensors test

Sensorstestcheckscorrectoperationofthesensorsconnectedtothedevice.

Opensensorstestmenu(Setupmenu>Test>Sensors).

Press OK toperformthetest.

Thedisplaywillshowthecurrentsensorreadingbelowtheselecteditem.1)Severalsensorscouldbedisplayed,dependingonthesetoperatingmode.Inthiscase,selectrequiredsensor

through .

2)PressESCtoquit.

Page 22: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

22

USE

Activatetherotatingpart.Thedisplaywillstartshowingthedetectedvalue.

Partialtotalizerreset

Toresetatotalizeryoumustviewitinextendedmode.Presskeyseveraltimesuntilvaluetoberesetisatthecentralareaofthedisplay.

Press keyfortwoseconds.

Totalizerresets.

Symbol-----indicatesthatthevalueexceedsthemaximumvaluethatcanbedisplayed.Totalizersdisplaymaximum4digits.

Page 23: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

23

MAINTENANCE / DIAGNOSTICS / REPAIRS

•Cleanonlywithasoftwetcloth.•Donotuseaggressivedetergentsorproducts.•Donotcleanequipmentwithdirectwaterjets.

Troubleshooting

FAULT CAUSE REMEDY

VISIOisoffordoesnotswitchon

Nopowersupply Checkpowercableconnections

DeviceisOFF PresstheONkey

VISIOshowswrongdata

Wrongsetup Checkdisplayeddatasetup

Sensorfault ContactthenearestAssistanceCenterVISIOfault

Fillingpump(ifany)doesnotstart

PumpStopModulenotpowered

Checkpowersupplyconnection

END OF LIFE DISPOSAL

Disposeofthesystemincompliancewiththeestablishedlegislationinthecountryofuse.

Page 24: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

24

TECHNICAL DATA

Devicetechnicaldata

Description VISIO

Display GraphicLCD,128x64pixels,back-lighting

Powersupplyvoltage 9÷16Vdc

Protectionagainstshort-circuit •

Protectionagainstpolarityinversion •

Max.frequency 1.2KHz

Analoginputs 4÷20mA

Digitaloutput-Maxcurrent 100mA

Maximumpowerinput(withnosensorsconnected) 160mA

Operatingtemperature -20°C÷70°C-4°F÷+158°F

Storagetemperature -30°C÷80°C-22°F÷+176°F

Size 126x79x66mm

Weight 245g

Page 25: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

25

Setupmenu

Data Min. Max. Default UoM Notes

Sensor Calibration 1.0 200.0 60.0 pls/l --

Rpm alarms

Min.RPM 1 9999 OFF RPM Alarmcanbedisabledbysettingvalueto"OFF"

Max.RPM 1 9999 OFF RPM Alarmcanbedisabledbysettingvalueto"OFF"

Display Contrast 0 100 50 % --

Options Language - - English -

Availablelanguages:Italiano,English,Español,Português,Français,Deutsch,Cesky,Polski,Русский,Magyar,ニホン .

Page 26: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

26

GUARANTEE TERMS

1. ARAGs.r.l.guaranteesthisapparatusforaperiodof360days(1year)fromthedateofsaletotheclientuser(dateofthegoodsdeliverynote).Thecomponentsoftheapparatus,thatintheunappealableopinionofARAGarefaultyduetoanoriginaldefectinthematerialorproductionprocess,willberepairedorreplacedfreeofchargeatthenearestAssistanceCenteroperatingatthemomenttherequestforinterventionismade.Thefollowingcostsareexcluded:

- disassemblyandreassemblyoftheapparatusfromtheoriginalsystem;- transportoftheapparatustotheAssistanceCenter.2. Thefollowingarenotcoveredbytheguarantee:- damagecausedbytransport(scratches,dentsandsimilar);- damageduetoincorrectinstallationortofaultsoriginatingfrominsufficientor

inadequatecharacteristicsoftheelectricalsystem,ortoalterationsresultingfromenvironmental,climaticorotherconditions;

- damageduetotheuseofunsuitablechemicalproducts,forspraying,watering,weedkillingoranyothercroptreatment,thatmaydamagetheapparatus;

- malfunctioningcausedbynegligence,mishandling,lackofknowhow,repairsormodificationscarriedoutbyunauthorizedpersonnel;

- incorrectinstallationandregulation;- damageormalfunctioncausedbythelackofordinarymaintenance,suchascleaning

offilters,nozzles,etc.;- anythingthatcanbeconsideredtobenormalwearandtear.3. Repairingtheapparatuswillbecarriedoutwithintimelimitscompatiblewiththe

organizationalneedsoftheAssistanceCenter.Noguaranteeconditionswillberecognizedforthoseunitsorcomponentsthathavenotbeenpreviouslywashedandcleanedtoremoveresidueoftheproductsused;

4. Repairscarriedoutunderguaranteeareguaranteedforoneyear(360days)fromthereplacementorrepairdate.

5. ARAGwillnotrecognizeanyfurtherexpressedorintendedguarantees,apartfromthoselistedhere.NorepresentativeorretailerisauthorizedtotakeonanyotherresponsibilityrelativetoARAGproducts.Theperiodoftheguaranteesrecognizedbylaw,includingthecommercialguaranteesandallowancesforspecialpurposesarelimited,inlengthoftime,tothevaliditiesgivenhere.InnocasewillARAGrecognizelossofprofits,eitherdirect,indirect,specialorsubsequenttoanydamage.

6. ThepartsreplacedunderguaranteeremainthepropertyofARAG.7. Allsafetyinformationpresentinthesalesdocumentsregardinglimitsinuse,

performanceandproductcharacteristicsmustbetransferredtotheenduserasaresponsibilityofthepurchaser.

8. AnycontroversymustbepresentedtotheReggioEmiliaLawCourt.

Page 27: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

CONFORMITY DECLARATION

1. ARAGs.r.l.guaranteesthisapparatusforaperiodof360days(1year)fromthedateof

Page 28: Software rel. 2.3 · 2020. 4. 8. · The machine is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and farming machines), harmonized

42048 RUBIERA (Reggio Emilia) - ITALYVia Palladio, 5/ATel. +39 0522 622011Fax +39 0522 [email protected]

Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the internet address www.aragnet.com

D20

287_

GB

-m04

03/2

017