22
SMART EPC: Record of Inspection & Site Notes Inspection Surveyor E-Mail Address [email protected] Report Reference Patrick Mathiot Date of Inspection Property Address 109 Vardon Drive LEIGH-ON-SEA SS9 3SJ 1355824 13 October 2021 Property Photo Created On 12 October 2021

SMART EPC: Record of Inspection & Site Notes

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

SMART EPC: Record of Inspection & Site Notes

Inspection Surveyor

E-Mail Address [email protected]

Report Reference

Patrick Mathiot

Date of Inspection

Property Address 109 Vardon DriveLEIGH-ON-SEASS9 3SJ

1355824

13 October 2021

Property Photo

Created On 12 October 2021

General Property Information

Transaction Type Marketed Sale

Tenure Owner Occupied

Type of Property House

Detachment Semi-Detached

Habitable rooms Total: 4 Heated: 4 Un-Heated: 0

Number of extensions 1

Main property age 1930-1949

Established By· enquiries of owner

Extension 1 age 1930-1949

Established By· enquiries of owner

Room in Roof Main Building: Yes Extension 1: No

Conservatory Separated, fixed heaters

Terrain Suburban

Wind Turbines None

Internal/External measurements Internal

Ventilation method Natural ventilation

Has fixed air conditioning Yes

Dimensions

Area (m2) Height (m) Heat Loss (m) PWL (m)

Main Property

62.99Floor 0 22.832.5 6.38

Extension 1

20.16Floor 0 16.152.5 0

External Condition

Main Wall Solid Brick wall of 260mm thickness with insulation as built, U-Value Unknown

Observed external indicators of Solid Brick Construction:· consistent with build age

Observed internal indicators of Solid Brick Construction:· no indicators identified

Observed indicators of Solid Brick Construction in Roof Space:· No indicator of construction visible

Party wall construction type:· Solid / timber frame / system built

Extension Wall Solid Brick wall of 260mm thickness with insulation as built, U-Value Unknown

Observed external indicators of Solid Brick Construction:· consistent with build age

Observed internal indicators of Solid Brick Construction:· no indicators identified

Observed indicators of Solid Brick Construction in Roof Space:· No indicator of construction visible

Party wall construction type:· Not applicable

Total glazed area A typical amount

Proportion double glazed 100

Double glazing installed Unknown Period

Are the window frames PVC Yes

What size is the glazing gap 16mm or more

Internal Condition

Main Floor Ground Floor, Solid - Insulation Type As Built, Unknown U-Value

Extension 1 Floor Ground Floor, Suspended, timber - Insulation Type As Built, Unknown U-Value

Main Roof Construction: Pitched, loft access Insulation: Joists Thickness: 100mm U-Value: Unknown

Main Room In Roof Age Range: 1930-1949 Insulation: All Elements - 100mm Floor Area: 29.8

Extension 1 Roof Construction: Pitched, loft access Insulation: Joists Thickness: 100mm U-Value: Unknown

Number of open fireplaces 0

Rooms with bath and/or ANY shower 2

Rooms with MIXER shower AND bath 1

Rooms with MIXER shower and NO bath 1

Waste water heat recovery system type None

Number of external doors 2

Number of insulated external doors 0

Draughtproofing percentage 100

Primary system Boiler Id: 008577 System Type: 1998 or later - Standard, auto ignition Manufacturer: Potterton Original Manufacturer: Baxi Potterton Model: Suprima - 70L

Services

Electricity meter type Single

Mains gas available Yes

Heating type SEDBUK Boiler - Standard

Boiler type Boiler

Fan flue Fan

Flue type Not open flue

Emitters Radiators

Primary system

Model: Suprima - 70L Seasonal Eff: 78.6

Percentage of space provided 100%

Controls Programmer, room thermostat and TRVs

Central heating pump age Unknown

Boiler has a Flue Gas Heat Recovery System (F No

Secondary heating Fuel: Mains Gas System:Flush fitting live fuel effect open front fire, sealed to fireplace

Water Heating Type Regular

Water Heating From From main heating 1

Water heating storage Cylinder Size: Large (>170 litres) Insulation: Factory Fitted (50mm)

Water heating controls Thermostat

Solar Photovoltaic None

Solar Hot Water None

Total light fittings 21

Low energy lights 21

Addendum / Related Party Disclosure

Addendum None

Related part disclosure No related party