SL1500 Wind Turbine Technical Data Sheet
TYPE SL1500/70 SL1500/77 SL1500/82 Wind turbine class IEC Ⅱ/Ⅲ/S IEC Ⅲ IEC Ⅱ/Ⅲ Rated power(kW) 1500 1500 1500 Cut-in wind speed(m/s) 3 3 3 Rated wind speed(m/s) 12 11 10.5 Cut-out wind speed(m/s) 25 20 20 Survival wind speed(m/s) 59.5/52.5 59.5/52.5 59.5/52.5
Normal temperature type
Low temperature type
Normal temperature type
Low temperature type
Normal temperature type
Low temperature type
Operating temperature range ()
-15~+45 -30~+45 -15~+45 -30~+45 -15~+45 -30~+45 Survival temperature () -25~+45 -45~+45 -25~+45 -45~+45 -25~+45 -45~+45 Longevity of design (year) 20 20 20
Operation
Averaged availability of wind farm (%)
≥95 ≥95 ≥95
Rotor diameter(m) 70.4 77.4 82.9 Swept area(m2) 3892.5 4657 5398 Rated rotational speed/range(rpm)
20.1/11.5~21.2 17.4/9.7~19 17.4/9.7~19
Number of blades 3 3 3
Rotor
Rotational direction (from up wind)
Clockwise clockwise clockwise
PROPRIETARY INFORMATION For use pursuant to the terms of the applicable Sinovel Agreement
Cone angle (°) 0 0 0 Tilt angle (°) 4.5 4.5 4.5 Power Regulation pitch Pitch pitch Blade length (m) 34 37.5 40.25
Blades Material
GRP (glass reinforced plastic)
GRP (glass reinforced plastic)
GRP (glass reinforced plastic)
Type Double-fed induction generator
Double-fed induction generator
Double-fed induction generator
Number of Phase 3 3 3 Rated power(kW) 1520 1520 1520 Rated output voltage(V) 690 690 690 Frequency(Hz) 60 60 60 Rated rotational speed/range (rpm)
2096/1200~2400 2096/1200~2400 2096/1200~2400
Power factor Capacitive 0.95 ~ inductive 0.9 Rated: 1
Capacitive 0.95 ~ inductive 0.9 Rated: 1
Capacitive 0.95 ~ inductive 0.9 Rated: 1
Protection level IP54 IP54 IP54 Insulation level F F F
Transformer rating
35kV/0.69kV 35kV/0.69kV 35kV/0.69kV
Number of transformer
1 1 1
Generator
Generator Step-up transformer data
Winding Dyn11 Dyn11 Dyn11
PROPRIETARY INFORMATION For use pursuant to the terms of the applicable Sinovel Agreement
Connection Impedance 7% 7% 7%
Drive stage 3 3 3 Drive ratio 1:104 1:120 1:120 Gearbox Rated power (kW) 1700 1700 1700 Major brake system Air-braking Air-braking Air-braking
Brake system Minor brake system mechanical braking mechanical braking mechanical braking
Control system Type PLC PLC PLC Capacity (KVA) 500 500 500 input/output voltage (VAC) 690/0~700 690/0~700 690/0~700 Input/output current (A) 200/500 200/500 200/500 Converter Range of input/output frequency (Hz)
60±1% / 0~20 60±1% / 0~20 60±1% / 0~20
type tubular steel tower tubular steel tower tubular steel tower Tower
Hub height (m) 65/70/80 65/70/80/100 70/80 Active Active Active
Type/design Sliding bearing with pre-friction
Sliding bearing with pre-friction
Sliding bearing with pre-friction
Drive Multistage planetary gear driven by conversion asynchronous motor
Multistage planetary gear driven by conversion asynchronous motor
Multistage planetary gear driven by conversion asynchronous motor
Yaw system
Range of yaw speed (°/min) 18.3~23.2 18.3~23.2 18.3~23.2
Pitch bearing type 4 points contact ball bearing4 points contact ball bearing
4 points contact ball bearing Pitch system
Pitch drive Multistage planetary gear Multistage planetary gear Multistage planetary gear
PROPRIETARY INFORMATION For use pursuant to the terms of the applicable Sinovel Agreement
driven by conversion asynchronous motor
driven by conversion asynchronous motor
driven by conversion asynchronous motor
Design standard IEC61024 and local ambient
IEC61024 and local ambient
IEC61024 and local ambient Lightning protection
Resistance of earthing (Ω) ≤4 ≤4 ≤4 Nacelle (kg) 55614 55614 55614 Rotor (kg) 16462 16462 16462 Weight Blades (kg) 3×5500 3×5900 3×6300
If annual mean wind speed is about 6 to 7 m/s in local wind farm, we suggest that SL1500/77 or SL1500/82 wind turbines may be installed here. Especially, the later one is a better choice.