SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA Forum Inovasi Distribusi Jakarta, 23-24 Februari

SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

Embed Size (px)

DESCRIPTION

SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA. Forum Inovasi Distribusi. Jakarta, 23-24 Februari. Engineer. Blogger. Backpacker. Hiker. Love the smell of nature & urban spirit. Your Presenter Today!. ANGGA RAJASA. Assistant Engineer SCADA & IT @ DCC Semarang. This is Our Menu :. - PowerPoint PPT Presentation

Citation preview

Page 1: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

Forum Inovasi Distribusi

Jakarta, 23-24 Februari

Page 2: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

Your Presenter Today!

Assistant Engineer SCADA & IT @ DCC Semarang

ANGGA RAJASA

Blogger

Engineer

Hiker

Backpacker

Love the smell of nature & urban spirit

Page 3: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

This is Our Menu :Change!

Baking Simple Idea

How do we make it

Result !

What’s Next ?

Page 4: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

Change!

Waiting the Information

Getting the Information

THIS IS BUSINESS!Whose FASTER, They WIN!

Page 5: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

It’s SimpleIt’s Simple

It’s Simple

Server Robot Komunikasi

Data Center Logger Alarm

Remote Terminal Unit -Ethernet Based

Automatically Checking

USB Plugging

Baking the Simple IdeaUSB GSM Modem

Cell phone

Send Alarm

Send Alarm

Page 6: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

This is it!, How!START

DAFTAR IP RTUindex =1

Index >= total

daftar IP RTU ?

STOP

Cek Komunikasi

RTU via test PING

Data RTU alarm ada

di database

Cek RTU sama ada di alarm logger ?

index++

update set status RTU = Normal

Insert ke dalam logger alarm

Set waktu RTU alarm dan status RTU =

alarm

Membandingkan selisih waktu alarm RTU saat

pertama kali dengan saat robot berjalan

Selisih waktu alarm = setingan waktu ?

Kirim SMS ke Petugas

NOK

OK

Request Time Out

Replied

Ada Tidak Ada

Tidak Ada

Tidak Ada

Ada

Ada

Page 7: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

Result!

Anywhere

RelaxIt’s Going on Air!

Page 8: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

It’s leaping!

FromNOdata Into so MANY data!

Growing Faster!

Page 9: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

JULI AGUST SEPT OKT NOV DES0

100

200

300

400

500

600

Total Jam / Bulan

Total Jam / Bulan

Result

JULI AGUST SEPT OKT NOV DES0

1,000

2,000

3,000

4,000

5,000

6,000

7,000

8,000

Kali / Bulan

Kali / Bulan

0.00

10.00

20.00

30.00

40.00

50.00

60.00

Gangguan lebih dari 1 Jam

Dalam Jam

With More Data :

Much Easier

Reducing Manual

More Accurate

Page 10: SISTEM PERINGATAN DINI GANGGUAN KOMUNIKASI SCADA

What’s Next ?Has to be Measurable Evaluated

This is Remote Terminal Unit Fault This is Fault Response

Time of Response

Time of explaining to user after response

It’s Challenge!