Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 1/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5 SPEC table5.1 Function SPEC
Legend(**H:Hex, ****B:Binary, No-mark:Decimal00H:Without,01H:With)Address LABEL
DATA DESCRIPTION Default
0000H Door_Reopen_Time 00 / 01When SES, PSES, OPEN B/T activated, itpermits door time SPEC.(V4.03 , VT3.00 )
00
0002H Crt_id * H CRT Supervisory panel ID ( E/L No .ID) 01H
0004H Housing_Corp 00 / 01 Special Option (Korea) 00H
0006H Observation 00 / 01 Observation E/L : 01 00H
0008H Car_Door_Lock 00 / 01 Car Door Locking Device Option : 01 00H
000AH Anti Crime Operation 00 or 01In case security operation is applied toSPEC, set 0x01H
00H
BH - EH Unused 00H
0010H Earthquake_Slow 00 / 01 Unused 00H
0012H Earthquake 00 / 01 Earthquake Control operation 00H
0014H Voice_to_RS232 00 or 01In case DOV-200 is applied to CP, set 01H(V2.05 )
00H
0016H Rope_Compen 00 / 01 Slack rope compen.:01 00H
0018H Weight Sensor * H
Load Sensor Type + Number of sensor
Pontio-Meter:40H, Weighing Device: 00Hex) Two PTM installed: 42H
One PTM installed: 41H
41H
001AH ESMI_ID *H ESMI ID Setting ( Korea Domestic only) 00H
001CH ESMI_Operation 00 / 01 ESMI Operation ( Korea Domestic only) 00H
001EH ARD(ALP)_Operation 00 / 01 ARD(ALP)_Operation 00H
0020H CRT_Operation 00 / 01 Supervisory panel applied : 01 00H
0022H Running_Open 00 / 01 RUNNING OPEN function :01 00H
0024H Mis_Call_Cancel 00 / 01Anti-nuisance control(Control spec: 015A setting)
00H
0026H Call_Cancel * HCar call cancel function(00:No function., 01:One touch, 02:TwoTouch, 04:One Touch Holding)
01H
0028H Hall_Chime_Gong 00 / 01 Chime attached to hall :01 00H
002AH Hall_Call_Cancel * HHall call cancel function( 00:No function., 01:One Touch, 02:TwoTouch)
00H
002CH Fireman_Drive 00 / 01 Fireman operation function :01 (V2.03 ) 00H
002EH Fireman_Open_Cut 00 / 01Door close standby when firemanoperation arriving(When Door open B/T
pressed OPEN :01H)
01H
0030HCall_Cancel_Non_Stop_SW
00 / 01Call deletion function by Non Stop switchOn.
01H
0032H Auto_Private_Power 00 / 01 Generator power operation: 01 00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
2/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 2/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex, ****B:Binary, No-mark:Decimal00H:Without,01H:With)Address LABELDATA DESCRIPTION Default
1 bit : DOWN 0 bit: UP3 bit : Getting off 2 bit: Door closing5 bit : Overload 4 bit: Full (80%)
0034H Voice_Guide_Spec1
1 Announ.Assigned
per1 bit 7 bit : VIP 6 bit: Service floor
FFH
1 bit : Power fail 0 bit : Fire detec.3 bit : Failure 2 bit : Auto rescue5 bit : Standbypower operation
4 bit : Parking0036H Voice_Guide_Spec2
1Announ.Assigned
per
1 bit 6 bit : Earthquake
FFH
0038H Chime_RTC_Spec 00/01Night chime prohibition function (When itapplied:Volume, Chime Cut)(Time control function spec setting)
00H
003AH Ref_FL_RTC_Spec 00 / 01
Function of changing reference floor 1stor2ndAccording to the traffic.(Time control function spec setting)
00H
003CHForce_Stop_Operation
00 / 01Compulsion stop FL function(01H)(Compulsion stop floor spec setting)
00H
003EH OBS_Operation 00 / 01 OBS switch function :01 01H
0040H Heavy_Wind_Oper 00 / 01 Heavy wind operation function : 01 00H
0042H Russia_Code 00 / 01 Russia Code 00H
0044H Rope_Gripper 00 / 01 Rope Gripper 01H
0046H Load_Auto_Adjust 00 / 01 Load auto compensation function(01H) 01H
0048H Exit Floor Fire Detect 00/01Exit Floor Fire Detect(Second exit floor)
For UAE (V2.03 )00H
004EH Dir_Reverse 00 / 01Cut the priority service for operationdirection by car call
01H
0050H Photo_Shoe 00 / 01 Photo Shoe (01H) 01H
0052H Housing Corp.Local CRT 00 / 01 Housing Corp Local CRT(KOREA) 00H
0054H Hall_Lantern 00 / 01 Hall Lantern (01H) 00H
0056H Voice_Output_Time * HAnnunc. Starting time for arrival(Unit:sec)* Available range(2~5sec)
02H
0058H Chime_Output_Time * HChime Starting time for arrival (Unit: sec)* In case that the Annunc. Is applied4sec, is not applied 2sec
04H
005AH Multi_Step_Decel 00 / 01Multi_Step_Deceleration functionAddress 011AH, 0422H, 0424H set
00H
005CHHousing_Corp_Fire_Option
00 / 01 Special fire option (Korea) 00H
005EH Cooler operation 00 / 01 Operation for draining water from Air-conditioner 00H
0060H Chime_Removal_Time23 hour isregistered
Chime/Gong prohibition startingtime(Hour)
22H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
3/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 3/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex, ****B:Binary, No-mark:Decimal00H:Without,01H:With)Address LABELDATA DESCRIPTION Default
0062H Chime_Removal_TimeChime/Gong prohibition starting time(Minute)
00H
0064H Chime_Removal_TimeChime/Gong prohibition finishing time( Hour)
06H
0066H Chime_Removal_Time
as 23H(ex)Toprohibitsound for23:30~06:300060H: 23H0062H: 30H0064H: 06H
0066H: 30H Chime/Gong prohibition finishing time(Minute)
00H
0068H Ref1_Select_TimeStart time for using 1streferencefloor(Hour)
18H
006AH Ref1_Select_TimeStart time for using 1streference floor(Minute)
00H
006CH Ref1_Select_TimeFinish time for using 1streference floor(Hour)
19H
006EH Ref1_Select_Time
Same asabove
Finish time for using 1
st
reference floor(Minute) 00H
0070H Ref2_Select_TimeStart time for using 2nd reference floor(Hour)
07H
0072H Ref2_Select_TimeStart time for using 2ndreference floor(Minute)
00H
0074H Ref2_Select_TimeFinish time for using 2ndreference floor(Hour)
08H
0076H Ref2_Select_Time
Same asabove
Finish time for using 2ndreference floor(Minute)
00H
00C8H User Velocity Adjust 00 or 01Approval of speed compensation: 0x01(Need to reduce or increase the speed by
1m/min unit)
00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
4/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 4/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.2 Control SPECLegend(**H:Hex, ****B:Binary, No-mark:Decimal00H:Without,01H:With)Addres
sLABEL
DATA DESCRIPTION Default
Capacity CODE
Persons 6 8 9 10 11
Code 06H 08H 09H 0AH 0BHPersons 13 15 17 20 24
0100H Capacity
*H
*(16=17persons)
Code 0DH 0FH 11H 14H 18HMOTOR CODE
kW 4.5 5.5 7.5 9.50102H Motor * HData 01H 02H 03H 04HkW 11 15 18 22
Data 05H 06H 07H 08H(Motor for modernization)
kW 7.5 11 15 22Data
Sigma MotorkW 4.5 5.5 7.5 9.5 11
Data 21H 22H 23H 24H 25HkW 13 15 18 22
Data 26H 27H 28H 29HRated speed CODE (m/min)
Speed 15 30 45 60Code 01H 02H 03H 04H
Speed 75 90 1050104H Contract_Velocity * H
Code 05H 06H 07H
0106H TM_Gear *HWorm Gear Type:01H
Helical Gear Type:02H01H
T/M M/C CODE(Worm Gear Type)
TKXS
38.5
TKXS
22.67
TKM
38.5
TKM
22.67
TKL
4701H 02H 03H 04H 05H
TKL
26.67
TKXL
47
TKXL
26.67
TYS
31.33
TYM
38
06H 07H 08H 09H 0AH
TYS
56
TYS
56
TYS
28.33
TYM
67
TKXL
26.67
0BH 0CH 0DH 0EH 0FH
TKL
25.33
TKM
30.33
TKM
45.5
TKM
62
EM
65
10H 11H 12H 13H 14HTKL
31.33
TKL
37.5
TKL
55
TKL
75
TYS
31.33
0108H Traction_Machine_code
15H 16H 17H 18H 19H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
5/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 5/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex, ****B:Binary, No-mark:Decimal00H:Without,01H:With)Address
LABELDATA DESCRIPTION Default
TYS
37
TYS
37.5
EM
56
TYS
42
TKM
67
1AH 1BH 1CH 1DH 1EH
TKM
17.25
EM
24.5
WLC-2
24
WLC-2
26
WLC-232.67
1FH 20H 21H 21H 23HWMC-2
22
WMC-2
25.67
WMC-2
38.5
EM
27.67
EM
53
24H 25H 26H 27H 28HTYS
21.75
TYS
33.33
DL
49
DL
27.5
29H 2AH 2BH 2CH
TYS
37
TYS
42
TKL
23.25
30H 31H 32H
TR M/C CODE Helical Gear)
H437C
36.41
H439C
38.68
H438B-S
37.85
H422B-S
21.9201H 02H 03H 04H
H322C
21.69
H421C
20.98
H317C
17.371
H309B
9.0
05H 06H 07H 08H
HYS
8.98
H438B-2
37.85
H422B-2
21.92
H438B-D
37.85
09H 0AH 0BH 0CHH422B-D
21.92
0DH IGBT Capacity (A)50, 75 100 150 200010AH IGBT * H01H 02H 03H 04H
03H
1 Turn(13Kw more than) 01H010CH CT_Turn * H
2 Turn(11Kw more less) 02H01H
Encoder pulse count72 512 1024 3600 8192010EH Encoder * H
01H 02H 03H 04H 05H03H
ROPING CODE
1 : 1 2 : 1 4 : 10110H Roping * H
01H 02H 04H
01H
0112H Maint_Velocity * HMaintenance and floor heightmeasurement operation speed CODE15m/min01H
01H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
6/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 6/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex, ****B:Binary, No-mark:Decimal00H:Without,01H:With)Address
LABELDATA DESCRIPTION Default
0114H Brake_C_Cntl 00 / 01 Brake current control function 01H0116H Brake_Current * H 00H0118H Unused
011AH Second_Ref_V *H2nd uniform velocity data (When appliedMulti-step deceleration function)* Refer to the Rated speed code
00H
011CH High_FHM-V *H
High FHM speed code* Refer to the Rated speed codeCaution: Set the data smaller thanpermitted speed that lift crash into buffer
00H
011EH Two_Speed_Err_Run 00 / 01Permitting normal operation after 2nd
deceleration error occurrence (01H)00H
00H0142H-0144H
Compen_Rope_Adjust * HCompensation chain/T-cable loadcompen. (for strain gauge type) 00H
00H0146H-0148H
No_Load_Point * HNo load Offset point- Field setting 00H
00H014AH-014CH
Full_Load_Point * HFull load Offset point- Field setting 00H
014EH 0150H
Half_Load_Point * H Half load Offset point- Field setting
00H
0152H Inv_Noload_Cur No load current compensation data 00H
0154H Inv_Slip_CMotor 2nd time constant compensation
data00H
0156H Unused
0158HFull_Load_Detect_
Percent* H Bypass point of load (80% => 50) 50H
015AH No_Of_Mis_Call *HNuisance call detection count: HEX
ex) Total 10 floors B/D 10*0.8=8
00H
015CH-
0162HLDC_Point.On * H LDC ON DELAY PULSE COUNT 00H
0164H -
016AHLDC_Point.Off * H LDC OFF DELAY PULSE COUNT 00H
016CH
0172HLDU_Point.On * H LDU ON DELAY PULSE COUNT 00H
0174H-
017AHLDU_Point.Off * H LDU OFF DELAY PULSE COUNT 00H
017CH-
0182H LDD_Point.On * H LDD ON DELAY PULSE COUNT 00H0184H-
018AHLDD_Point.Off * H LDD OFF DELAY PULSE COUNT 00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
7/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 7/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.3 Inverter SPECLegend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABEL
DATA DESCRIPTION Default
0200H INV_V_PI_Gain *H Input data within 46H ~ 82H(70~130) 64H0202H Inv_Linear_10 *H Speed command when level before
10mm07H
0204H Inv_Comp_Dist *H Advanced distance adjusting value forleveling control
06H
0206H Inv_Adj_125 *H Compen. value of distance 125mm 0FH0208H Load_Compen_Gain
* Reverse shock Adj.1. Opposite side:
2. Straight side:
*H Load compen. value gain(E/L speed; 60m/min -> 30HE/L speed ; 90~105m/min->50H)
30H
OR50H
020AHLoad_Regen_Factor *H
Gain value during regeneration.(E/L speed; 60m/min -> 07HE/L speed ; 90~105m/min->1EH)
07HOR1EH
020CH Load_Compen_Offset[0]
*H Higher floor rope compensation.(Not applied compen. Chain)
00H
020EH Load_Compen_Offset[1]
*H Intermediate floor rope compensation.(Not applied compen. Chain)
00H
0210H Load_Compen_Offset[
2]
*H Lower floor rope compensation.
(Not applied compen. Chain)
00H
0212H Pgc_Gain *HProfile deceleration specificationposition gain (Long distance traveling)
10H
0214H Short_Pgc_Gain *HProfile deceleration specificationposition gain (Shot distance traveling)
00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
8/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 8/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.4 Floor SPECLegend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
0300H Total * H Total floor (Number of shelter plate installed) 80306H Display_Char[0][0] 20H Unused 20H0308H Display_Char[0][1] 20H Unused 20H
030AH Display_Char[1][0] * H1FL 2-figures indicating character(Nothing:20H)
B
030CH Display_Char[1][1] * H 1FL 1-figure indicating character 1030EH Display_Char[2][0] * H 2FL 2-figures ASCII CODE
0310H Display_Char[2][1] * H 2FL 1-figure "0" 30H "A" 41H 10312H Display_Char[3][0] * H 3FL 2-figures "1" 31H "B" 42H 0314H Display_Char[3][1] * H 3FL 1-figure "2" 32H "C" 43H 20316H Display_Char[4][0] * H 4FL 2-figures "3" 33H "D" 44H 0318H Display_Char[4][1] * H 4FL 1-figure "4" 34H "E" 45H 3031AH Display_Char[5][0] * H 5FL 2-figures "5" 35H "F" 46H 031CH Display_Char[5][1] * H 5FL 1-figure "6" 36H "G" 47H 5031EH Display_Char[6][0] * H 6FL 2-figures "7" 37H "H" 48H 0320H Display_Char[6][1] * H 6FL 1-figure "8" 38H "L" 4CH 60322H Display_Char[7][0] * H 7FL 2-figures "9" 39H "M" 4DH 0324H Display_Char[7][1] * H 7FL 1-figure "U" 55H "P" 50H 7
0326H Display_Char[8][0] * H 8FL 2-figures Nothing 20H - 2DH
0328H Display_Char[8][1] * H 8FL 1-figure 8032AH Display_Char[9][0] * H 9FL 2-figures 032CH Display_Char[9][1] * H 9FL 1-figure 9032EH Display_Char[10][0] * H 10FL2-figures 0330H Display_Char[10][1] * H 10FL 1-figure 80332H Display_Char[11][0] * H 11FL 2-figures 0334H Display_Char[11][1] * H 11FL 1-figure 90336H Display_Char[12][0] * H 12FL 2-figures 10338H Display_Char[12][1] * H 12FL 1-figure 0033AH Display_Char[13][0] * H 13FL 2-figures 1033CH Display_Char[13][1] * H 13FL 1-figure 1033EH Display_Char[14][0] * H 14FL 2-figures 10340H Display_Char[14][1] * H 14FL 1-figure 20342H Display_Char[15][0] * H 15FL 2-figures 10344H Display_Char[15][1] * H 15FL 1-figure 30346H Display_Char[16][0] * H 16FL 2-figures 10348H Display_Char[16][1] * H 16FL 1-figure 4034AH Display_Char[17][0] * H 17FL 2-figures 1034CH Display_Char[17][1] * H 17FL 1-figure 5034EH Display_Char[18][0] * H 18FL 2-figures 10350H Display_Char[18][1] * H 18FL 1-figure 60352H Display_Char[19][0] * H 19FL 2-figures 10354H Display_Char[19][1] * H 19FL 1-figure 70356H Display_Char[20][0] * H 20FL 2-figures 1
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
9/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 9/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
0358H Display_Char[20][1] * H 20FL 1-figure 8
035AH Display_Char[21][0] * H 21FL 2-figures 1035CH Display_Char[21][1] * H 21FL 1-figure 9035EH Display_Char[22][0] * H 22FL 2-figures 20360H Display_Char[22][1] * H 22FL 1-figure 10362H Display_Char[23][0] * H 23FL 2-figures 20364H Display_Char[23][1] * H 23FL 1-figure 20366H Display_Char[24][0] * H 24FL 2-figures 2
0368H Display_Char[24][1] * H 24FL 1-figure 3036AH Display_Char[25][0] * H 25FL 2-figures 2036CH Display_Char[25][1] * H 25FL 1-figure 4
0386H Display_Char[32][0] * H 32FL 2-figures 30388H Display_Char[32][1] * H 32FL 1-figure 203CEH Display_Char[3][1] * H 1FL 3-figures 3-DIGIT applied 03D0H Display_Char[3][2] * H 2FL 3-figures 03D2H Display_Char[3][3] * H 3FL 3-figures 03D4H * H 4FL 3-figures 03D6H * H 5FL 3-figures 03D8H * H 6FL 3-figures 03DAH * H 7FL 3-figures 03DCH * H 8FL 3-figures 03DEH * H 9FL 3-figures 03E0H * H 10FL 3-figures 03E2H * H 11FL 3-figures 03E4H * H 12FL 3-figures 03E6H * H 13FL 3-figures 03E8H * H 14FL 3-figures 03EAH * H 15FL 3-figures 03ECH * H 16FL 3-figures 03EEH * H 17FL 3-figures 03F0H * H 18FL 3-figures 040AH * H 31FL 3-figures 04ACH * H 32FL 3-figures
038AH Service_Inform[0][0] Unused
038CHService_Inform[0][1]
* HService information on 1st FLLDC-installed stop floor and LDC-installed non-stop floor to be classified (Include rear door)
C1H
With shelter plate
B7 B6B5B0
1 0
038EH
* H
Non-stop FL->
Stop FL -> 1 1
FloorData
C2HC3H
C8H00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
10/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 10/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
03C8H Ex) 2 FL non-stop : 82H = 10000010B3 FL stop : C3H = 11000011B
03CAHService_Inform[0][32]
* HService information on 32nd FL(Non-stop floor does not need marking)
00H
03CCH- 00 / 01 3-DIGIT applied (V2.0 ~) 00
040EH Parking * H If use PARKING floor (01H) 01H0410H Reference1 * H Reference FL(If '0', no return to reference FL) 01H0412H Reference2 * H 2ndreference FL 00H
0414H Exit1 * H Escape floor 01H0416H Exit2 * H 2ndescape floor 00H
0418H Dispersion1 * HDispersion FL during DUPLEX (If 0,no dispersion)
* Dispersion FL =( reference FL +top FL)/200H
041AH Dispersion2 * H Unused041CH Top * H Top floor 08H041EH Middle * H Intermediate FL 04H0420H Bottom * H Bottom floor 01H
0422H Up_Decel_Zone *HMulti-step deceleration start floor in up direction(Two rows shelter plate installed floor)
(V2.02 ~)
00H
0424HDown_Decel_Zon
e*H
Multi-step deceleration start floor in downdirection(Two rows shelter plate installed floor)(V2.02 ~)
00H
042CH Hall_Lantern_Dir 00 / 01 Lantern with direction lamp function 00H042EH Security _Option 00 / 01 Security Floor Option (NV 4.01~) 042EH
0430H Security _Floor[1] *H 1~8 Floor Security Floorset(NV 4.01~) 0430H
0432H Security _Floor[2] *H 9~16 Floor Security Floorset (NV 4.01~) 0432H
0434H Security _Floor[3] *H 17~24 Floor Security Floorset (NV 4.01~) 0434H
0436H Security _Floor[4] *H 25~32 Floor Security Floorset (NV 4.01~) 0436H
0434H -047EH
Unused
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
11/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 11/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.5 Car node SPECLegend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
0500H DCL_ID 00 / 01 ID No.1 OPB (Main DCL applied) 01H
0502H Installed_Node[1] 00 / 01 ID No.2 OPB (Sub 1 DCL applied) 00H
0504H Installed_Node[2] 00 / 01 ID No.3 OPB (Sub 2 DCL applied) 00H
0506H Installed_Node[3] 00 / 01 ID No.4 OPB (Sub 3 DCL applied) 00H
0508H Installed_Node[4] 00 / 01ID No.5 Rear OPB (Rear Main DCL applied)
VT3.00 ~
00H
050CH Bt_Bz_Cut 00 / 01 Cage Button BZ sound Cut (V2.03~) 00H050EH Bt_Bz_Toggle 00 / 01 EFO(Russia) BZ sound applied(V2.03~) 00H0510H DML_Indi 00 / 01 DML CPI 01H0512H Lamp_Indi 00/01 Lamp type CPI applied :01 00H
Setting usage of additional CPI lamp 1 06H
Without
Full
Inspect
Emergency
VIP
0H 1H 2H 3H 4H
Inuse
Auto
Full
Safety
Off
0514H Sub_Lamp1 *H
6H 7H 8H 9H
0516H Sub_Lamp2 *H Setting usage of additional CPI lamp 2 01H
0518H Sub_Lamp3 *H Setting usage of additional CPI lamp 3 02H
051AH Sub_Lamp4 *H Setting usage of additional CPI lamp 4
051CH 051EH
Unused
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
12/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 12/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.6 Hall Node SPECLegend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
0600H *H Two lines of Hall net ex) Duplex 00H
0602H~0608H
Use_Bside Unused
VIP B/T Installed FL (Max. 3 FL)060AH
1 - 8 FL 5000060AH Add 00H060CH 9 - 16FL 5000060CH Add 00H060EH 17 - 24FL 5000060EH Add 00H
0610H
VIP_Button * B
25 - 32FL 50000610H Add 00H
0612H -0632H
Unused
0634H DML Indi 00 / 01 DML Indi applied 01H
0636H Double DHG 00 / 01When 1 of DHG-161 PCB is used for 2 floors01H
01H
Setting usage of additional indicator lamp 1 01H
With
out
Fu
ll
Insp
ect
Emergency
VIP
Sta
rt
0H 1H 2H 3H 4H 5H
Inuse
Auto
Full
Safety
Off
0638H Sub_Lamp1 *H
6H 7H 8H 9H
063AH Sub_Lamp2 *H Setting usage of additional indicator lamp 2 02H
063CH Sub_Lamp3 *H Setting usage of additional indicator lamp 3 00H
063EH Sub_Lamp4 *H Setting usage of additional indicator lamp 4 00H
0640H Unused
0642HButton_Jam_Detect_ Time
* HButton Jam Detecting time Unit : secex) In case 180sec (3 min) => 0xB4
B4H
0644H 064AH
Unused
064CH Lamp_Indi 00 / 01 Lamp Type INDI 00H
064EHCall_Related_INDI
00 / 01 B/T call related Indicator (VIX-532) 00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
13/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 13/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
Indi_On_Floor * B B/T call related Indicator usually on floor
0650H 1 ~ 8FL 00H0652H 9 ~ 16FL 00H0654H 17 ~ 24FL 00H
0650H -0656H
0656H 25 ~ 32FL 00H0658H -0676H
Unused
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
14/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 14/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.7 Door SPECLegend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABEL
DATA DESCRIPTION Default
0700H 00 / 01V2.06 more than : UnusedV2.05 more less : DAV Door applied
00H
0702H Nudging 00 / 01 Nudging device 00H0704H Unused 00 / 01 00H
0706HDoor_Lock_Magnet
00 / 01 Car door locking 00H
0708H Close_Buzzer 00 / 01 Close buzzer 00H
070AH Open_Bt_Flick 00 / 01 Open button lighting ON 01H
070CHEarthquake_Door_Close
00 / 01Door closing after completion
of earthquake control operation00H
070EH Fire_Door_Close 00 / 01Door closing after completion
of fire control operation00H
0710HAuto_Private_Power_Door_Close
00 / 01Door closing after completion
of private power control operation00H
0712H Unused
0714HClose_Lock_Limit_Count
* HDoor operation count for detecting CloseLock
0CH
0718HDoor Type
(Through type)*H
In case of through typeV2.06 more than : UnusedV2.05 more less : SAV & MAV => 01
00H
0798H Open_Time[0] FFH FFH079AH Open_Time[1] 00H Unspecified Door Time 00H
079CH Open_Time[2] * HDoor Opening Time for hall call (sec)3 sec=03H, 2 sec = 02H, 1sec = 01H
03H
079EH Open_Time[3] * H Door Opening Time for car call (sec) 02H
07A0H Open_Time[4] * HDoor Opening Time of non-condition(sec)
05H
07A2H Open_Time[5] * H Opening Time for disabled persons (sec) 05H
07A4H Open_Time[6] * H Opening Time for Control operation (sec) 0FH07A6H Unused 00H07A8H Open Time[8] * H Door open time of reference floor(sec) 05H07AA~
07B6HUnused
07B8H Door Type * H
Door TypeV2.06 more than:SBD => 00HADS_K => 01H,SAV & MAV => 02HDAV => 03HV2.5 more less: Unused
02H
07BAHUse_Ref_Base_FL_Door Time
00 / 01
When door time for reference floor isapplied, set 0x01(In case this function is applied to system,address 07B8 also be set)
00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
15/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 15/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
07CAH Unused 00 / 01 In case of Russia Apartment (TCD-240) 00H07CCH Return Floor Auto
Open00 / 01 Door open automatically, arrived at escape
floor under fire operation.(Russia)00H
07CEHPhoto_Reopen_Cut_Cnt
* H Max. Reopen count by Photo sensor 05H
07D0H Photo_Cut_Buzzer 00 / 01 Buzzer work when photo beam cut (close) 01H07D2H Photo_Cut_Limit * H Photo beam cut limit time (sec) 20H07D4H LDS_Off_BZ_Time * H Landing Door open detecting time(sec) 0AH
07D6H CLS_Hold CLS contact holding DMC Cut(Only for SBD1 door_DCD210 applied) 00H
07D8H Photo_Non_Cut 00 / 01In case photo sensor function must beignored during nudging close, set 0x01
00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
16/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 16/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.8 Call service SPECLegend(**H:Hex, ****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABEL
DATA DESCRIPTION Default0800H -0808H
Unused
080AHNon_Stop1_Trigger_Cond
00 / 01 NON STOP1 Switch 01H
080CHNon_Stop2_Trigger_Cond
00 / 01 NON STOP2 Switch 01H
080EH -
081CH
Unused 00H
081EH 7FH0820H 00H0822H 00H0824H
Hall_Up_Call * B Setting in HALL UP CALL available FL bit
00H
0826H FEH
0828H 00H082AH 00H082CH
Hall_Down_Call * BSetting in HALL DOWN CALL available FLbit
00H082EH FFH0830H 00H
0832H 00H0834H
A_Cage_Call_Patt * BSetting in E/L #1 A type(front side) CAR
CALL available bit00H
0836H -083CH
Unused 00H
083EH FFH0840H 00H0842H 00H0844H
B_Cage_Call_Patt * BSetting in E/L #1 B type(rear side) CARCALL available bit
00H
0846H -084CH
Unused
084EH 55H
0850H 55H
0852H 55H
0854H
Non_Stop_1 * BSetting in NON STOP1 specified FL bit Svcpattern used when switch input.* Set to service FL
55H
0856H ABH0858H 00H085AH 00H085CH
Non_Stop_2 * B
Setting in NON STOP2 specified FL bit Svcpattern used when switch input.* Set to service FL
00H
Setting in compulsion stop FL bit for UPdirection
085EH
Force_Stop[0] * B
085EH 1 ~ 8FL 00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
17/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 17/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex, ****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
0860H 0860H 9 ~ 16FL 00H
0862H 0862H 17 ~ 24FL 00H
0864H 0864H 25 ~ 32FL 00H
Setting in compulsion stop FL bit for DOWNdirection
0866H 0866H 1 ~ 8FL 00H
0868H 0868H 9 ~ 16FL 00H
086AH 086AH 17 ~ 24FL 00H
086CH
Force_Stop[1] * B
086CH 25 ~ 32FL 00H
086EH- Car_Call_Priority 00 / 01 Priority service for car call (V2.09 ) 00H
08D8H Single_Service_M
ap[1] * H A_Side General call service MAP(DSKA--SKA)81H
08DAH Single_Service_M
ap[2] * HB_Side General call service MAP(DSKA--SKA)
42H
08DCH Single_Service_M
ap[3]* H A_Side Disable call service MAP(DSKA--SKA)
21H
08DEH Single_Service_M
ap[4] * HB_Side Disable call service MAP(DSKA--SKA)
12H
08E0HHall_Service_Map[0]
* H General call service map 83H
08E2H Hall_Service_Map[1]
* H General call service map for rear side doorIn case fo through type : 41H
41H
08E4HHall_Service_Map[2]
* H Disabled person call service map 23H
08E6HHall_Service_Map[3]
* HDisabled person call service map for rearSide door
00H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
18/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 18/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex, ****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
Definition of service map
7 6 5 4 3 2 1 0A
TypeB/T
BTypeB/T
CTypeB/T
DTypeB/T
HoldFlag
E/LNo.2
E/LNo.1
* Hold Flag : In case hall call is registered , even if service type is changed tonon-stop floor, it will service before reset.
A Type B/T : HALL NET 1 line DHG HU/HD
B Type B/T : HALL NET 2 lines DHG HU/HD C Type B/T : HALL NET 1 line DHG HUC/HDC D Type B/T : HALL NET 2 lines DHG HUC/HDC) 83HA Type B/T setting for E/L No. 1 and 2
21HC Type B/T setting for E/L No. 108E8H
~08EAHButton_Pattern[0] * B Front side Hall call floor Bit Set 00H
08F0H~ 08F2
Button_Pattern[1] * B Rear side Hall call floor Bit Set 00H
08F8H Hall_Call_Inform[0
]
00 / 01 Through type applied (VT3.0~) SET : 01 00H
08FCH Hall_Call_Inform[2]
00 / 01 Through type applied (VT3.0~) SET : 01 00H
0900H * H
0902H * H
0904H * H
0906H
Aside_Hall_Station
* H
In case that 2 floors are under control of 1DHG-161(V2.06 , VT3.01 , DHG V4.01 )A type of hall call floor(7thpin of dip SW1 on DHG-161 is OFF)(1st ~ 32nd floor)
0908H * H
090AH * H
090CH * H
090EH
Bside_Hall_Station
* H
In case that 2 floors are under control of 1DHG-161(V2.06 , VT3.01 , DHG V4.01 )B type of hall call floor(7thpin of dip SW1 on DHG-161 is ON)(1st ~ 32nd floor)
091F -09FCH
Unused Unused
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
19/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 19/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.9 Dispatch SPECLegend(**H:Hex, ****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
0A00H *H 32H
0A02HRef_Fl_Wait_Car
*H
Addition value for stand-by lift atreference floor0032H = 50Delay time = 50 * 100 ms = 5 s
00H
0A04H *H 32H
0A06HNon_Dir_Car
*H
Addition value for stand-by lift withoutdirection5sec 00H
0A08H *H 03H0A0AH Closed_Car *H
Subtraction value for door closed lift300ms 00H
0A0CH *H 02H
0A0EHReady_To_Run_Car
*HSubtraction value for ready to running200 ms 00H
0A10H * H 00H0A12H
Run_Car* H
Subtraction value for running lift00H
0A14H * H 00H0A16H
Unused* H 00H
5.10 Parallel running specLegend(**H:Hex, ****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION Default
0A80H SPD_Nplex_Timer[0] *HAssistance operation detecting timer(sec)Setting time :28H(40sec)~78H(120sec)
32H(50sec)
0A82H SPD_Nplex_Timer[1] *HStart of dispersion delay timer (sec)Setting time :00H ~ 3CH(60sec)
1EH(30sec)
0A84H SPD_Nplex_Timer[2] *HStart of dispersion delay timer (Min)Setting time :00H ~ 3CH(60Min)
V2.05
00H
0A86H SPD_Nplex_Timer[3] *H Unused FFH
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
20/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 20/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.11 Virtual input SPECLegend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABEL
DATA VIRTUAL INPUT SPEC
0B00H -0B2EH
Fixed input area
0B30H VID_Vi_Map[0][12][0] VI_SD2U0B32H VID_Vi_Map[0][12][1] 01H0B34H VID_Vi_Map[0][13][0] VI_SD2D0B36H VID_Vi_Map[0][13][1] 01H
0B38H -0B52H
Fixed input area
VID_Vi_Map[port no.][bit no.][0] : inputspecificationVID_Vi_Map[port no][ bit no.][][1] : statespecificationstate specification) 01Hreverse (B-CON)
00H normal (A-CON)ex) VID_Vi_Map[0][3][0] = VI_DLD
VID_Vi_Map[0][3][0] = 00HBit 3 of port No. 0 is used DLD input,input state is A-CON
0B54H VID_Vi_Map[1][5][0] VI_LDU 00H VI_NULL 16H VI_R4HW
0B56H VID_Vi_Map[1][5][1] 01H 01H VI_R5SC 17HVI_MAINT_C
0B58H VID_Vi_Map[1][6][0] VI_LDD 02H 18H0B5AH VID_Vi_Map[1][6][1] 01H 03H VI_UL 19H0B5CH VID_Vi_Map[1][7][0] VI_R4FM 04H VI_DL 1AH0B5EH VID_Vi_Map[1][7][1] 00H 05H VI_R5SCS 1BH
06H 1DH0B60H -0B62H
Fixed input area07H 1EH
0B64H VID_Vi_Map[1][9][0] VI_R4EQ 08H 1FH
0B66H VID_Vi_Map[1][9][1] 00H 09H 20H0B68H VID_Vi_Map[1][10][0] VI_R7NP 0AH 21H VI_SD1U
0B6AH VID_Vi_Map[1][10][1] 01H 0BH 22H VI_SD2U
0B6CH VID_Vi_Map[1][11][0] VI_R4GS 0CH 23H VI_SD1D
0B6EH VID_Vi_Map[1][11][1] 00H 0DH 24H VI_SD2D
0B70H VID_Vi_Map[1][12][0] VI_R4CT 0EH 25H VI_LDC0B72H VID_Vi_Map[1][12][1] 00H 0FH 26H0B74H VID_Vi_Map[1][13][0] VI_R2UL 10H VI_V48 27H VI_LDU
0B76H VID_Vi_Map[1][13][1] 00H 11H VI_R5SX 28H VI_LDD0B78H VID_Vi_Map[1][14][0]
VI_PARKING
12H VI_MAINT_M 29H VI_C1BR
0B7AH VID_Vi_Map[1][14][1] 00H 13H VI_R1MU 2AH VI_C1ST0B7CH VID_Vi_Map[1][15][0] 00H 14H VI_R1MD 2BH VI_CDS0B7EH VID_Vi_Map[1][15][1] 00H 15H 2CH VI_LDS0B80H VID_Vi_Map[2][0][0] VI_ERO 2DH VI_DOLS 4DH0B82H VID_Vi_Map[2][0][1] 00H 2EH VI_DCLS 4EH VI_R4GS
0B84H VID_Vi_Map[2][1][0] 00H 2FHVI_SAFETY_SHOE
4FH VI_R4CT
0B86H VID_Vi_Map[2][1][1] 00H 30H 50H
0B88H VID_Vi_Map[2][2][0] VI_DB 31H 51H0B8AH VID_Vi_Map[2][2][1] 01H 32H 52H0B8CH VID_Vi_Map[2][3][0] VI_6LS 33H 53H0B8EH VID_Vi_Map[2][3][1] 01H 34H 54H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
21/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 21/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA VIRTUAL INPUT SPEC
0B90H VID_Vi_Map[2][4][0] VI_C1SW0B92H VID_Vi_Map[2][4][1] 01H
35H 55H
36H 56H0B94H VID_Vi_Map[2][5][0] 00H 37H 57H0B96H VID_Vi_Map[2][5][1] 00H 38H 58H
39H 59H0B98H -0B9AH
Fixed input area3AH 5AH
0B9CH VID_Vi_Map[2][7][0] 00H 3BH 5BH
0B9EH VID_Vi_Map[2][7][1] 00H 3CH 5CH
3DH 5DHVI_1ST_FIRE0BA0H -
0BBEHUnused
3EH 5EHVI_2ND_FIRE
3FH 5FH VI_R1MM40H 60H VI_RDMC
41H VI_R7NP 61HVI_PARKING
42H 62H43H VI_R7RD 63H VI_HIGH
44H VI_R4FM 64H VI_ERO45H VI_R4FS 65H VI_BD
46H VI_EQ 66H VI_C1SW
47H 67H VI_6LS
48H 68HVI_RR_THB
49H
4AH
4BH
4CH
* mark is fixed input (cant be edited)
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
22/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 22/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.12 Virtual output SPEC
Legend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA VIRTUAL INPUT SPEC
0C00H -0C52H
Fixed output area
0C54H VID_Vo_Map[14][0] 00H0C56H VID_Vo_Map[14][1] 00H0C58H VID_Vo_Map[14][2] 00H
0C5AH VID_Vo_Map[15][0] 00H0C5CH VID_Vo_Map[15][1] 00H
0C5EH VID_Vo_Map[15][2] 00H
VID_Vo_Map[Variable][0] : Output port specificationVID_Vo_Map[Variable][1] : Output bit specificationVID_Vo_Map[Variable][2] : Output state specificationstate specification) 01Hreverse (B-CON)
00Hnormal (A-CON)ex) VID_Vo_Map[0][0] = 1H
VID_Vo_Map[0][1] = 0HVID_Vo_Map[0][2] = 0H
Bit 0 of port No. 1 is used C1BR output, non-reverse.
0C60H VID_Vo_Map[16][0] 00H Variable Description0C62H VID_Vo_Map[16][1] 00H 0 VO_C1BR0C64H VID_Vo_Map[16][2] 00H 1 VO_C1ST0C66H VID_Vo_Map[17][0] 01H 2 VO_R5SC0C68H VID_Vo_Map[17][1] 0DH 3 VO_OPEN0C6AH VID_Vo_Map[17][2] 00H 4 VO_CLOSE0C6CH VID_Vo_Map[18][0] 02H 5 VO_WHEEL_CHAIR_DOOR
0C6EH VID_Vo_Map[18][1] 05H 6 VO_NUDGING0C70H VID_Vo_Map[18][2] 00H 7 VO_R1ML
8 VO_COOLER0C72H -0C76H
Fixed output (R1HI)9 VO_CAR_LIGHT
0C78H VID_Vo_Map[20][0] 02H 10 VO_CAR_FAN
0C7AH VID_Vo_Map[20][1] 03H 11 VO_INV_FAN
0C7CH VID_Vo_Map[20][2] 00H 12 VO_R4F1
0C7EH VID_Vo_Map[21][0] 02H 13 VO_R4F2
0C80H VID_Vo_Map[21][1] 02H 14 VO_EQ_RESET
0C82H VID_Vo_Map[21][2] 01H 15 VO_V_WAVE_RESET
0C90H VID_Vo_Map[24][0]VO_RT
D16 VO_RESCUE_RETURN
0C92H VID_Vo_Map[24][1] 00H 17 VO_R2DM
0C94H VID_Vo_Map[24][2] 00H 18 VO_R4RF
0C96H VID_Vo_Map[25][0]VO_RR
D19 VO_R1H1
0C98H VID_Vo_Map[25][1] 00H 20 VO_ROPE_GRIPPER0C9AH VID_Vo_Map[25][2] 00H 21 VO_R4FSX
22 VO_LDS_OFF_BUZZER
23 VO_RDZ24 VO_RTD0CBEH VID_Vo_Map[31][2]25 VO_RRD
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
23/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 23/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.13 Timer SPEC
Legend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABEL
DATA DESCRIPTION
0D00H -0D30H
Fixed Timer area
0D38H Direction error detecting 5400D40H R5SC On/Off error detecting 5400D48H C1ST On/Off error detecting 540
0D50H Operation mode input errordetecting
990
0D58H -0D60H
Fixed Timer area
0D68H 0D6E
C1BR Off error detecting 540
0D80H C1BR On error detecting 1200
0D88HSuppress On/Off errordetecting
360
0D90H 0D98H
Fixed Timer area
0DA0H C1SW On/Off error detecting0DD0H VOICE_CLOSE_START_T 990
0DD8H 0E08H
Fixed Timer area
0E10H Car FAN Off Timer 50000E18H Unused0E20H Unused0E28H Cooler draining timer 30060
0E30H -0E48H
Fixed Timer area
0E50H Unused0E58H Unused0E60H Unused0E68H Extend Open timer 180000
0E70H -0E78H
Fixed Timer area
0E80H CLOSE_LOCK_DETECT_T 100800E88H CLOSE_LOCK_50SEC_T 500400E90H OPEN_LOCK_DETECT_T 10080
0E98HDOOR_THERMO_DETECT_T
30060
0EA0H BACKUP_OP_DETECT_T 100800EA8H -0ED0H
Fixed Timer area
0ED8H POSI_OFF_ERR_T 2070
m sec. is indicated according to timer spec.timer value is 4 byte variable.Value is specified in address and reverseorder in EEPROM.Ex.) TM_PHOTO_OFF_DETECT isdisplayed by
$50000D10H |($50000D12H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
24/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 24/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
Legend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABELDATA DESCRIPTION
0EE0H Encoder broken wire detecting 16200EE8H BRAKE_OFF_DETECT_T 30600EF0H -0FA0H
Fixed Timer area
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
25/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 25/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.14 In car Virtual input SPEC
Legend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABEL
DATA VIRTUAL INPUT SPEC
1000H -101AH
Fixed input area
101CH CND_I_Map[0][7][0] 00H101EH CND_I_Map[0][7][1] 00H
1020H -1036H Fixed input area
1038H CND_I_Map[1][6][0] 00H103AH CND_I_Map[1][6][1] 00H
CND_I_Map[port no.][bit no.][0] : input specificationCND_I_Map[port no.][bit no.][1] : state specificationex) 01Hreverse (B-CON)
00Hnormal (A-CON)ex) CND_I_Map[0][3][0] = CN_UP
CND_I_Map[0][3][1] = 00HBit 3 of port No. 0 is UP input, state is reversed.
spec Description spec Description103CH -104AH
Fixed input area00H CN_NULL 16H CN_NON_STOP1
104CH CND_I_Map[2][3][0] 00H 01H CN_HIGH 17H CN_NON_STOP2104EH CND_I_Map[2][3][1] 00H 02H CN_IN_CAR 18H CN_P_SHOE
1050H CND_I_Map[2][4][0] 00H 03H CN_ON_CAR 19HCN_CALL_PRIORITY
1052H CND_I_Map[2][4][1] 00H 04H CN_ATT 1AH CN_1ST_FIRE
1054H 05H CN_INDP 1BH CN_2ND_FIRE1056H
Fixed input area06H CN_PARK 1CH
1058H CND_I_Map[2][6][0] 00H 07H CN_EFS 1DH
105AH CND_I_Map[2][6][1] 00H 08H CN_OPEN 1EH
09H CN_E_OPEN 1FH105CH -1072H
Fixed input area0AH CN_CLOSE 20H CN_WATER_FULL
1074H CND_I_Map[3][5][0] CN_LW2 0BH CN_UP 21H CN_DCPU
1076H CND_I_Map[3][5][1] 01H 0CH CN_DOWN 22H CN_DERR2
1078H CND_I_Map[3][6][0] CN_LW8 0DH CN_START 23H CN_DERR1107AH CND_I_Map[3][6][1] 00H 0EH CN_BY_PASS 24H CN_DERR0
107CH CND_I_Map[3][7][0] CN_LW11 0FH CN_DCO 25H CN_CLS
107EH CND_I_Map[3][7][1] 01H 10H CN_LW2 26H CN_MON
11H CN_LW8
12H CN_LW11
13HCN_ON_CAR_CLOSE
14HCN_ON_CAR
_UP15H
CN_ON_CAR_DOWN
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
26/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 26/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.15 Hall call service permitted code SPEC
Legend(**H:Hex, ****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABEL
DATA DESCRIPTION
1560HSPD_Hall_Svc_Option_Spec[NORMAL_SVC]
01H Normal call service permitted 01H
1562HSPD_Hall_Svc_Option_Spec[BSIDE_SVC]
00H Rear call service permitted 01H
1564HSPD_Hall_Svc_Option_Spec[WHEEL_SVC]
01H Disabled persons call service permitted 01H
bit 0 VIP service
bit 1When this bit is set, car callcanceled
immediately
bit 2
0 : VIP mode is canceled during deceleration for last car call1 : VIP mode is canceled afterdoor close
completion of last car callbit 3 Lock Type Buttonbit 4bit 5bit 6
1566HSPD_Hall_Svc_Option_Spec[VIP_SVC]
Notpermit00H
permit07H
bit 7
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
27/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 27/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.16 Parallel Operation Mode Permit Code SPEC
Legend(**H:Hex, ****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABEL
DATA DESCRIPTION1570H NCD_Bit_Acd[0].Operation 0 Operation bit definition
1572H NCD_Bit_Acd[0].Ref_Fl 0 bit 0Anti-nuisance controlfunction stopped
1574H NCD_Bit_Acd[0].Dis_Fl
Non-controlmode
0 bit 1Hall floor, directionIndication stopped
1576H NCD_Bit_Acd[1].Operation 0 bit 2 Lantern function stopped
1578H NCD_Bit_Acd[1].Ref_Fl 59H bit 3 Chime /gong functionstopped
157AH NCD_Bit_Acd[1].Dis_Fl
ATTmode
0 bit 4 Assistance operation valid157CH NCD_Bit_Acd[2].Operation 23H bit 5 Close B/T invalid
157EH NCD_Bit_Acd[2].Ref_Fl 0 bit 6Specified floor returnpermitted
1580H NCD_Bit_Acd[2].Dis_Fl
VIPstandbymode
0 bit 7Dispersion start delaypermitted
1582H NCD_Bit_Acd[3].Operation 0FH1584H NCD_Bit_Acd[3].Ref_Fl 0
Ref_Fl( Dis_Fl ) bit definition
1586H NCD_Bit_Acd[3].Dis_Fl
VIPrunningmode 0 bit 0 Non-Inter-Lock
1588H NCD_Bit_Acd[4].Operation 10H bit 1 Zone dispersion158AH NCD_Bit_Acd[4].Ref_Fl 55H bit 2
Start floor advance controlpermitted
158CH NCD_Bit_Acd[4].Dis_Fl
Officeattendance mode
0 bit 3Door open after dispersioncomplete
158EH NCD_Bit_Acd[5].Operation 80H bit 4UP direction whendispersion
1590H NCD_Bit_Acd[5].Ref_Fl 51H bit 5DOWN direction whendispersion
1592H NCD_Bit_Acd[5].Dis_Fl
Singlemode
0 bit 6Dispersion operationpermitted
1594H NCD_Bit_Acd[6].Operation 90H bit 71596H NCD_Bit_Acd[6].Ref_Fl 50H1598H NCD_Bit_Acd[6].Dis_Fl
Parallelmode
42H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
28/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 28/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.17 Floor height TableLegend(**H:Hex,****B:Binary,No-mark:Decimal00H:without,01H:with)Address LABEL
DATA DESCRIPTION Default1A00H 1A08H
1A0AH 1A10H
Floor height measured data for 1stfloor
1A12H 1A1AH
Floor height measured data for 2ndfloor
1A1CH
1A24H
Floor height measured data for 3rdfloor
1B10H-1B16H
FHT_SUM * H Floor height table sum data
5.18 Performance SPEC
Legend(**H:Hex,****B:Binary,No-
mark:Decimal00H:without,01H:with)Address LABEL DATA DESCRIPTION Default
3E00H Velocity_Adjust * H
Parameter ( Rated velocity adjust )* Max. adjust range4 m/min
speed-down : 001H, 002H, 003H,
004H
Speed-up : 081H, 082H, 083H, 0
84H
00H
3E02H Time 9 * H
Time setting of 1st deceleration zonevelocity
: Rising Time Set (Multi-stepdecelerationfunction)
ex) 1sec : 010 1.5sec : 015
10H
3E04H Time 10 * H
Time setting of 1st deceleration zoneuniformvelocity (Multi-step deceleration
function)ex) 0.5sec : 005 2sec : 020
05H
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
29/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 29/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
5.19 Button type
Explanation of Service Map
Ex)
A B/T B B/T C B/T D B/T Hold No.2 No.1
Front normalHall call
1 1 1
Rear normalHall call
1 1
Front Disable
call
1 1
Rear Disablecall
In case of above
Front normal hall call Call will registered by A B/T input line, and E/L No.1,2 are able to
service.
Rear normal hall call Call will registered by A B/T input line, and E/L No.1 able to service.
Front disable call Call will registered by C B/T input line, and E/L No.1 is able to service.
Rear disable call Service is impossible because (there is no designated service lift and input
B/T)..
* The function of hold bit is for maintain the old registered Hall call and service when it
changes to Non-stop FL.
(Standard data is 0)
VIP call service depends on VIP floor pattern setting.
* B/T Type
Type DIP S/W 7 DHG B/T Connector STANDARD
A OFF HU/HD Front normal
B ON HU/HD Rear normal
C OFF HUC/HDC Front Disable
D ON HUC/HDC Rear Disable
*In case of parallel operation, hall network should be set same as simplex operation,
because each E/L has it own hall network configuration.
5.20 Floor SPEC and Dip S/W settingEx 1) DUPLEX operation: E/L No.1 information: (8/8, B3, B2, B1, 1~5), E/L No.2
7/25/2019 SIGMA LG-OTIS Di1(Si210) SPEC Table (Programacion)
30/30
Part SPEC tablen Di1(Si210) Elevator
Ctrl. No. SI-SR-01-1
Page 30/30FODOverseas Support Team
Start-up RoutineDate Nov. 2006
information: (6/6, B11~5) 2 hall line application
- Floor SPEC
ADDRESS LABEL No.1 DATA No.2 DATA Remark
0300H TOTAL 08H 06H
038CH S. INFOR C1H C3HNo.2 first shelter plate isStart from 3rdfloor
038EH C2H C4H
0390H C3H C5H
0392H C4H C6H
0394H C5H C7H0396H C6H C8H
0398H C7H 00H
039AH C8H 00H
0410H REFERENCE 1 04H 04H
0418H DISPERSION 1 07H 07H
041CH TOP 08H 08H
041EH MIDDLE 05H 05H
0420H BOTTOM 01H 03H081EH H_UP_CALL 7FH 7FH
0826H H_DN_CALL FEH FEH
082EH C_CAL_PATT FFH FFH
- Dip Switch setting of DHG 161 PCB
Floor No.1 No.2
5
4
3
2
1
B1
B2 N/A
B3 N/A
SW1 SW2
SW1 SW2
SW1 SW2
SW1 SW2
On 8 On 4
On 8 On 4
On 8 On 4
On 8 On 4
SW1 SW2
SW1 SW2
SW1 SW2
On 8 On 4