6
Shiley Flexible Adult Tracheostomy Tubes Next »

Shiley Flexible Adult Tracheostomy Tubes€¦ · TaperGuard ™ cuff, disposable inner cannula versus the Shiley DCT tracheostomy tube with disposable inner cannula at the same cuff

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Shiley Flexible Adult Tracheostomy Tubes€¦ · TaperGuard ™ cuff, disposable inner cannula versus the Shiley DCT tracheostomy tube with disposable inner cannula at the same cuff

Shiley™ Flexible Adult Tracheostomy Tubes

Next »

Page 2: Shiley Flexible Adult Tracheostomy Tubes€¦ · TaperGuard ™ cuff, disposable inner cannula versus the Shiley DCT tracheostomy tube with disposable inner cannula at the same cuff

SHILEY™ FLEXIBLE ADULT TRACHEOSTOMY SOLUTIONS

2 Covidien.com/ShileyFlexible

For more than 40 years, clinicians have counted on Shiley™ tracheostomy tubes to facilitate positive outcomes across the patient-care continuum. Today, the new generation of Shiley Flexible adult tracheostomy tubes builds on the brand’s heritage of quality and reliability with a range of product advances designed to enhance patient safety and simplify patient care.

THE NEW SHILEY™ FLEXIBLE TRACHEOSTOMY TUBES FOR ADULT PATIENTS

« Previous | Next »

Page 3: Shiley Flexible Adult Tracheostomy Tubes€¦ · TaperGuard ™ cuff, disposable inner cannula versus the Shiley DCT tracheostomy tube with disposable inner cannula at the same cuff

3Covidien.com/ShileyFlexible« Previous | Next »

WEANING

HELP ENABLE EASIER INSERTION AND REMOVAL• A thinner, less bulky cuff reduces insertion force by 39%.1 • A beveled tip on all product configurations eases percutaneous

insertion.

MAY ENHANCE PATIENT FIT AND COMFORT• The outer cannula is flexible enough to conform to the patient’s

airway, but rigid enough to maintain airway patency.• The tubes use sizing (I.D., O.D., length and tube curvature) that is

essentially equivalent with that used in earlier Shiley products.• Additional sizes have been added to improve patient fit when

needed.

INITIAL PLACEMENT

SKIN CAREMECHANICAL VENTILATION

WEANINGTRACHEA AND LUNG PROTECTION

MAY REDUCE THE RISK OF SKIN BREAKDOWN• The flange features a transparent, soft material designed to

conform to the patient’s clavicle to help reduce the risk of skin breakdown.

• The central portion of the flange has windows designed to improve airflow to sensitive skin. It is offset to help reduce contact with the patient’s skin.

HELP IMPROVE YOUR ABILITY TO PROVIDE MECHANICAL VENTILATION• The ability to titrate ventilator air leak is 65% greater

with the addition of TaperGuard™ cuff technology.2

HELP REDUCE WORK OF BREATHING• Airflow around the outer cannula when the

cuff is deflated has increased by an average of 242%.1

• Improved airflow may reduce the work of breathing required to speak and wean from a tracheostomy tube.5

HELP PROTECT THE LUNGS• With the TaperGuard™ cuff, the tube reduces fluid leakage by 99%.3

HELP REDUCE IMPACT ON THE TRACHEA• The tube exerts 18.6%4 less lateral wall pressure on the trachea.1

Page 4: Shiley Flexible Adult Tracheostomy Tubes€¦ · TaperGuard ™ cuff, disposable inner cannula versus the Shiley DCT tracheostomy tube with disposable inner cannula at the same cuff

SPECIFICATION OVERVIEW – PREVIOUS VERSUS NEW SHILEY FLEXIBLE TUBES

• Equivalent outer diameter and inner diameter sizing (with the inner cannula in place)

• Equivalent tube length across disposable inner cannula product lines

• Cuff resting diameter has changed due to the lower-profile cuff on the Shiley Flexible tracheostomy product line

• Additional sizes available in the Shiley Flexible tracheostomy product line

PRODUCT CODE LOGIC AND SIZING FOR SHILEY™ FLEXIBLE TRACHEOSTOMY TUBES

The first letters indicate a cuffed tube (CN) or uncuffed tube (UN)

The first number is the Jackson size

The second numbers indicate the ISO size as well as the inner diameter of the outer cannula

The last letter indicates disposable (H) inner cannula8 CN 85 H

Covidien.com/ShileyFlexible

SHILEY™ FLEXIBLE ADULT TRACHEOSTOMY SOLUTIONS

4 « Previous | Next »

Page 5: Shiley Flexible Adult Tracheostomy Tubes€¦ · TaperGuard ™ cuff, disposable inner cannula versus the Shiley DCT tracheostomy tube with disposable inner cannula at the same cuff

Shiley™ Flexible Adult Tracheostomy Tubes with Disposable Inner Cannula Previous Shiley™ Tracheostomy Tubes with Disposable Inner CannulaSIZE SKU# SPECIFICATIONS SKU# SPECIFICATIONS

Jackson ISO Cuffed Cuffless

Outer Cannula

Inner Diameter (mm I.D.)

Inner Cannula

Inner Diameter (mm I.D.)

Cannula Outer

Diameter (mm O.D.)

Length (mm)

Cuff Resting

Diameter (mm) Cuffed Cuffless

Inner Cannula

Inner Diameter (mm I.D.)

Outer Cannula

Outer Diameter

(mm O.D.)Length

(mm)

Cuff Resting

Diameter (mm)

4 6.5 4CN65H 4UN65H 6.5 5.5 9.4 62 20.6 4DCT 4DCFS 5.0 9.4 62 20.0

5 7.0 5CN70H 5UN70H 7.0 6.0 10.1 68 23.0

6 7.5 6CN75H 6UN75H 7.5 6.5 10.8 74 25.4 6DCT 6DCFS 6.4 10.8 74 24.0

7 8.0 7CN80H 7UN80H 8.0 7.0 11.4 77 25.4

8 8.5 8CN85H 8UN85H 8.5 7.5 12.2 79 26.6 8DCT 8DCFS 7.6 12.2 79 27.0

9 9.0 9CN90H 9UN90H 9.0 8.0 12.7 79 27.6

10 10.0 10CN10H 10UN10H 10.0 9.0 13.8 79 28.6 10DCT 10DCFS 8.9 13.8 79 29.0

SPECIFICATION OVERVIEW – PREVIOUS VERSUS NEW SHILEY FLEXIBLE TUBES

SHILEY™ FLEXIBLE ADULT TRACHEOSTOMY SOLUTIONS

5Covidien.com/ShileyFlexible« Previous | Next »

Page 6: Shiley Flexible Adult Tracheostomy Tubes€¦ · TaperGuard ™ cuff, disposable inner cannula versus the Shiley DCT tracheostomy tube with disposable inner cannula at the same cuff

References1. Based on internal testing comparing the Shiley™ Flexible adult tracheostomy tube with TaperGuard™

cuff to the Shiley™ DCT tracheostomy tube cuffed.2. Internal bench-top testing. Results reflect the Shiley™ Flexible adult tracheostomy tube with

TaperGuard™ cuff, disposable inner cannula tubes ability to titrate / control ventilator air leak in comparison to the Shiley™ tracheostomy tube cuffed with disposable inner cannula (DCT).

3. Internal bench-top. Results reflect testing the Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff, disposable inner cannula versus the Shiley™ DCT tracheostomy tube with disposable inner cannula at the same cuff pressure of 25 cm H2O.

4. Internal testing results. Results reflect measurements taken for size 7.5 Shiley Flexible adult tracheostomy tube compared to the Shiley 6DCT tracheostomy tube at 20 cm H20.

5. Mullins JB, Templer JW, Kong J, et al. Airway resistance and work of breathing in tracheostomy tubes. Laryngoscope. 1993;103(12):1367-1372.

COVIDIEN, COVIDIEN with logo, Covidien logo and positive results for life are U.S. and internationally registered trademarks of Covidien AG. Other brands are trademarks of a Covidien company. ©2015 Covidien. 14-AW-0122a(1) (US)

ORDERING INFORMATION

SIZE SKU#

Jackson ISO Cuffed Trach Tube Inner Cannula Cuffless Trach Tube Inner Cannula4 6.5 4CN65H 4IC65 4UN65H 4IC655 7.0 5CN70H 5IC70 5UN70H 5IC706 7.5 6CN75H 6IC75 6UN75H 6IC757 8.0 7CN80H 7IC80 7UN80H 7IC808 8.5 8CN85H 8IC85 8UN85H 8IC859 9.0 9CN90H 9IC90 9UN90H 9IC9010 10.0 10CN10H 10IC10 10UN10H 10IC10

Shiley™ Flexible Adult Tracheostomy Tubes with Disposable Inner Cannula1. Ability to ventilate with or

without the inner cannula in place

2. Suture holder on flange

3. Color coding by size (disposable inner cannula products only)

4. Citrate based plasticizer

1

2

3

4

6135 Gunbarrel Avenue • Boulder, CO 80301 • 800-635-5267 covidien.com/rms