Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
ACCURATE OR COMPLETE.
DRAWING TITLE:
PROJECT No:
SCALE SHEET No. REV.
QUALITY RECORD :
APPROVED
NBNCO APPROVAL RECORD:
DD
AB
WD
REV DATE DESCRIPTION
SIGNATURE DATE
IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS.
USE OF NBNCO LIMITED (ABN 86 136 533 741)THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE
NBNCO DISCLAIMER
NO WARRANTY IS GIVEN THAT THE INFORMATION IS
FOR USE IN MAINTAINING NBNCO FACILITIES.IT HAS NOT BEEN CREATED FOR ANY OTHER USE.
CADREF No:
NN KEY PLAN
OF
LimitedFSA:
STATE: REGION:
FSAM:
DRAFTER
FDA:
**ATTENTION** CONSTRUCTORSDO NOT change or alter job
specifications unless first checkingwith designer.
MAP1
MAP3 MAP4
MAP2
SHEET1
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
Stafford, QLD 4053204/6 Babarra Street
Fax: (07) 3872 5566Tel: (07) 3872 5555
E: [email protected]& ASSOCIATES PTY. LTD.
Robin
Russell
CONSULTING ENGINEERS - ELECTRICAL
www.robrus.com.au
A.B.N. 78 010 589 661
GAINSBOROUGH GREENS PRECINCT 7.2BYAWALPAH ROADPIMPAMA
QLD
AYCA-3QMMOS
B579
1:1000 1 1 C
A 13/09/2016 SHANE MILLS ORIGINAL K.R.
B 20/02/2017 SHANE MILLS REVISED CIVIL BASE K.R.
C 05/12/2017 A.C. AS BUILT S.M.
LEGEND: NBN CONDUITS & PITS
Fibre Distribution Hub (FDH) site - 1m x 1m
Fibre Access Node (FAN) site
Local Network PitPremises Connection (Houses an MPT)Boundary PitCross-Road & Other Premises Connection (No MPT)Local Network Connection PitPremises Connection & Fibre Splice ClosureDistribution Pitat entry/exit to estate; @ 250m ccs on distribution conduit
Fibre Distribution Hub (FDH) PitWithin 5m of FDH Site
FAN(2ARM)
Marker Post(Post to be numbered)
FDH-ID576
RC183A 22 Multi Dwelling Unit (MDU)
Descriptor Box(Description of type of work & Quantity involved)
DESCQTY
T Existing Telstra conduit trench layout(Proposed conduit indicated for comms cable)
Existing or proposed Energex pole (& pole ID)ID-001
Existing Telstra Exchange
Existing Telstra Pits (size 2,3,4,5,6,7,8 or 9)
Existing Telstra Manholes (Access Chambers)
Existing Traffic Signals Box
Existing network item to be removed/replaced
TransformerPad Mount / Pole Mount
PWR
Depth over alignment indicator(used with every Marker Post)
Proposed 100mm Main Conduit
Proposed 23mm Service Drop
TRF
Proposed shared trench
Proposed 50mm Lateral Conduit
Proposed length of bored conduit
Service Drop Access Pit
Existing NBN 100mm conduit
Existing Telstra P100 conduit
DEPTH-ALIGN -_._
_._
5
M01
PIT-XXX2
PIT-XXX5
PIT-XXX5
PIT-XXX8
PIT-XXX8
PIT-XXX9
P100 40
P50 25
P23 7
'C' communications marker plate
COM
1200mm
LV
A
B
GROUND LEVEL
SECTION VIEW
TAPE
LOCATION A
MINIMUM CONDUIT DEPTH *
Verge 450mm
Local Road 600mm
DTMR Road 800mm
B
750mm
Energex 800mm; Ergon 900mm
LV
100m
m
SHARED TRENCH DETAIL-NBN
PROP
ERTY
BOU
NDAR
Y
* supercedes Energex/Ergon requirements
PIT
PIT
Property Boundary
Kerb
ROAD
NO PITS IN THE SHADED AREA
MIN. 3m MIN. 1m
MIN.
1mMI
N. 3m
ROADFOOTPATH
AS CONSTRUCTED
1053
//
//
//
//
//
ROAD 1
ROAD 1
MOWBRAY
ST
MTROYAL
ST
CONIMBLA ST
KOSCIUSZKO CCT
GOLD COAST RAILWAY LINE
GOLD COAST RAILWAY LINE
(DUPLEX)
(DUPLEX)
BUTTERFEAF CR
KUMBATINE
ST
MT ROYAL ST
BARAKEE ST
BUTTERFEAF CR
GREAT
SANDY CCT
GREAT SANDY CCT
GREAT SANDY CCT
GREAT SANDY CCT
TOONUMBA ST
BUTTERLE
AF CRNANGAR ST
NANGAR ST
BUTTERFEAF CR
DUPLEX
DUPLEX
DUPLEX
DUPLEX
DUPLEX
PIT-0048
PIT-0055
PIT-0062
PIT-0072
PIT-0085PIT-0092PIT-0105
PIT-0112PIT-0125
PIT-0138
PIT-0148
PIT-0158
PIT-0165
PIT-0175
PIT-0185
PIT-01
92
PIT-0205
PIT-0218
PIT-0225
PIT-0235
PIT-0245
PIT-0252
PIT-0265
PIT-0272
PIT-028
PIT-0335
PIT-0348
PIT-0355
PIT-0368
PIT-0375
PIT-0388
PIT-0395
PIT-0405
PIT-0415
PIT-0428
PIT-0435
PIT-0442 PIT-0455
PIT-0462 PIT-
0475
PIT-0485
PIT-0492
PIT-0505
PIT-0518
160.3
P100
41.1
P100
P100
38.5
P100
42.9
P100
34.1
P100
50.8
P100
52.6P100
43.6P100
27.8
P100
45.0
P10012.2
P100
42.2
P100
27.7
P10015.5
P100
33.7
P50
53.0
P100
39.6
P100
33.6
P100
26.0
P100
33.5
P100
42.9
P100
35.5
P100
24.7
P100
33.2
P100
18.2
P100
40.0
P50
28.1
P1001.0
P10012.4
P100
26.2
P5017.3
P100
27.4
P100
26.7
P100
26.2
P100
18.6
P10013.7
P50
29.7
Development InformationDevelopment Name: Developer Company:
Authorised Rep:
Development Adress:
CRM ID: Stage Number:
Phone:E-Mail:
GAINSBOROUGH GREENS MIRVAC PACIFIC P/L
YAWALPAH ROAD, PIMPAMA
AYCA-3QMMOS PRECINCT 7.2B
TOM ALLISON07 3859 [email protected]
1035
1036
1037
1038
1039
1040
1041
1047
1042
1043
1044
1045
1046
1048
1049
1050
1051
1052
1053
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1019
1020
1021
1022
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1113
1128
1114
1115
1116
1117
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2013.0
P2017.0
P203.0
P203.0
P206.0
P2017.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2017.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2011.0
P203.0
P203.0
P203.0
PIT-0539
P1002.0
FDH-XXX
P1005.0
P100
46.0
P100
24.6
P50
19.3
P100
23.0
P100
25.8
P5017.1
P50 18.6
P50
29.8
P50
34.8
P5017.2
P50
17.6
P100
36.4
P100
23.7
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2014.0
P203.0
P2016.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P20
P50
19.2
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1172
1173
1174
1165
1166
1167
1158
1159
1160
1161
1162
1146
1147
1148
1149
1082
1083
1084
1085
1086
1087
1088
1089
1090
1139
1140
1141
1142
1143
1144
1145
1150
1151
1152
1153
1154
1168
1169
1170
1171
1080
1081
PIT-00
15
PIT-00
25
PIT-00
35
PIT-00
45
PIT-0
055
PIT-0
065
PIT-0075PIT-00
82
PIT-0098
PIT-0108PIT-0118
PIT-0125
PIT-0132
PIT-0142
PIT-0155
PIT-0165
PIT-0
175
PIT-0
185
PIT-01
95
PIT-02
0
2
PIT-02
1
8
PIT-02
2
5
PIT-0238
PIT-0245
PIT-0252
PIT-0262
PIT-0275
PIT-0288
PIT-0295
PIT-0305
PIT-0315
PIT-0325
P100
16
P100
31.7
P100
38
P100
39.6
P100
36.8
P100
34.4
P50
35.6
P100
47
P100
31.9
P10017.9
P50
33.5
P5018.7
P100
29.3
P1001
P100
49.2
P100
35.6
P1001
P501
P100
13.9
P100
23.6
P100
25.8
P5017.7
P100
27.9
P100
48.1
P100
37.4
P50
29.3
P10017.3
P100
27.6
P100
16.9
P203
P2010
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P2015
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P10017.6
P203
P203
P203
P2012
P203
P203
P203
P203
P203
P203
P203
P203
CONNECT TO EXISTINGNBN CONDUIT
CONNECT TO EXISTINGNBN CONDUIT
7Pit
PWR
PWR
PWR
EXISTING PRECINCT 7.2ARR&A # B578AYCA-2RECL1
P100
P5047.0
53
59
52
41 64
144
153
154
162
167139
36
31 74
129
134 172
177
179
26
79
EL (Y
ELLO
W)
EL (YE
LLOW
)
180
125
22
17
119
185
190
87
114
12
195
92
109
97
7
103
8
1
104
EL (Y
ELLO
W)
EL (YELLOW)
PIT-033
5
P100
68.5
P100
41.5
P100
73
P100
34.7
P50
20.2
P50
32
P100
27.2
P10011.3
P100
14.5
BILL OF MATERIAL
PITSSIZE2589
QTYDUCTS
SIZE QTY MTRSP100P50P23
TOTAL NUMBER OF PITS:TOTAL NUMBER OF CONDUITS:TOTAL LENGTH OF CONDUITS:
NO OF LOTS:
62160
31 936.28 18856 196
33951320.2
54
DRAWING TITLE:
PROJECT No:
SCALE SHEET No. REV.
QUALITY RECORD :
APPROVED
NBNCO APPROVAL RECORD:
DD
AB
WD
REV DATE DESCRIPTION
SIGNATURE DATE
CADREF No:
NN KEY PLAN
OF
LimitedFSA:
STATE: REGION:
FSAM:
DRAFTER
FDA:
**ATTENTION** CONSTRUCTORSDO NOT change or alter job
specifications unless first checkingwith designer.
MAP1
MAP3 MAP4
MAP2
SHEET1
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
Stafford, QLD 4053204/6 Babarra Street
Fax: (07) 3872 5566Tel: (07) 3872 5555
E: [email protected]& ASSOCIATES PTY. LTD.
Robin
Russell
CONSULTING ENGINEERS - ELECTRICAL
www.robrus.com.au
A.B.N. 78 010 589 661ACCURATE OR COMPLETE.
IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS.
USE OF NBNCO LIMITED (ABN 86 136 533 741)THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE
NBNCO DISCLAIMER
NO WARRANTY IS GIVEN THAT THE INFORMATION IS
FOR USE IN MAINTAINING NBNCO FACILITIES.IT HAS NOT BEEN CREATED FOR ANY OTHER USE.
GAINSBOROUGH GREENS PRECINCT 7.2AYAWALPAH ROADPIMPAMA
QLD
AYCA-2RECL1
B578
1:1000 1 1 E
A 04/12/2015 SHANE MILLS ORIGINAL K.R.
B 22/02/2016 SHANE MILLS FDH ADDED TO STAGE K.R.
C 08/09/2016 SHANE MILLS REVISED ZERO LOT BOUNDARIES K.R.
D 18/02/2017 SHANE MILLS REVISED CIVIL BASE K.R.
E 07/12/2017 A.C. AS BUILT S.M.
LEGEND: NBN CONDUITS & PITS
Fibre Distribution Hub (FDH) site - 1m x 1m
Fibre Access Node (FAN) site
Local Network PitPremises Connection (Houses an MPT)Boundary PitCross-Road & Other Premises Connection (No MPT)Local Network Connection PitPremises Connection & Fibre Splice ClosureDistribution Pitat entry/exit to estate; @ 250m ccs on distribution conduit
Fibre Distribution Hub (FDH) PitWithin 5m of FDH Site
FAN(2ARM)
Marker Post(Post to be numbered)
FDH-ID576
RC183A 22 Multi Dwelling Unit (MDU)
Descriptor Box(Description of type of work & Quantity involved)
DESCQTY
T Existing Telstra conduit trench layout(Proposed conduit indicated for comms cable)
Existing or proposed Energex pole (& pole ID)ID-001
Existing Telstra Exchange
Existing Telstra Pits (size 2,3,4,5,6,7,8 or 9)
Existing Telstra Manholes (Access Chambers)
Existing Traffic Signals Box
Existing network item to be removed/replaced
TransformerPad Mount / Pole Mount
PWR
Depth over alignment indicator(used with every Marker Post)
Proposed 100mm Main Conduit
Proposed 23mm Service Drop
TRF
Proposed shared trench
Proposed 50mm Lateral Conduit
Proposed length of bored conduit
Service Drop Access Pit
Existing NBN 100mm conduit
Existing Telstra P100 conduit
DEPTH-ALIGN -_._
_._
5
M01
PIT-XXX2
PIT-XXX5
PIT-XXX5
PIT-XXX8
PIT-XXX8
PIT-XXX9
P100 40
P50 25
P23 7
'C' communications marker plate
COM
1200mm
LV
A
B
GROUND LEVEL
SECTION VIEW
TAPE
LOCATION A
MINIMUM CONDUIT DEPTH *
Verge 450mm
Local Road 600mm
DTMR Road 800mm
B
750mm
Energex 800mm; Ergon 900mm
LV
100m
m
SHARED TRENCH DETAIL-NBN
PROP
ERTY
BOU
NDAR
Y
* supercedes Energex/Ergon requirements
PIT
PIT
Property Boundary
Kerb
ROAD
NO PITS IN THE SHADED AREA
MIN. 3m MIN. 1m
MIN.
1mMI
N. 3m
ROADFOOTPATH
AS CONSTRUCTED
PIT-0028
PIT-0038
PIT-0048
PIT-0055
PIT-0062
PIT-0072
PIT-0085PIT-0092PIT-0105
PIT-0112PIT-0125
PIT-0138
PIT-0148
PIT-0158
PIT-0165
PIT-0175
PIT-0185
PIT-01
92
PIT-0205
PIT-0218
PIT-0225
PIT-0235
PIT-0245
PIT-0252
PIT-0265
PIT-0272
PIT-0282
PIT-02
98
PIT-0308
PIT-0315
PIT-0335
PIT-0348
PIT-0355
PIT-0368
PIT-0375
PIT-0388
PIT-0395
PIT-0405
PIT-0415
PIT-0428
PIT-0435
PIT-0442 PIT-0455
PIT-0462 PIT-
0475
PIT-0485
PIT-0492
PIT-0505
PIT-0518
P100 17.0
P10019.1
P100
54.5
P100
35.1
P100
24.6
P100
38.5
P100
42.9
P100
52.6
P100
27.8
P10012.2
P100
42.2
P100
27.7
P100
33.7
P100
33.6
P100
26.0
P100
33.5
P100
35.5
P100
24.7
P100
40.0
P50
28.1
P10012.4
P100
26.2
P5017.3
P100
26.2
1035
1036
1037
1038
1039
1040
1041
1047
1042
1043
1044
1045
1046
1048
1049
1050
1051
1052
1053
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1014
1015
1016
1017
1018
1019
1020
1021
1022
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1113
1128
1114
1115
1116
1117
PWR
PWR
PIT-0528
P100
21.6
P100 35.9
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2014.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2013.0
P2017.0
P203.0
P203.0
P206.0
P2017.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2017.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2011.0
P203.0
P203.0
P203.0
GOLD COAST RAILWAY LINE
GOLD COAST RAILWAY LINE
1231
1232
1233
1234
1235
1236
1237
1238
1239
1108
1107
1112
1111
1110
1109
1118
1127
1126
1119
1120
1125
1124
1123
1121
1122
1129
1130
1131
1132
1133
1134 1140
1141
1142
1143
1144
1145
1149
1148
1147
1082 1076
1075
1083
1084 1074
1073
1085
1086
1072
1071
1087
1088
1070
1069
1089
1090
1068
1150
1139 1135
DUPLEX
DUPLEX
DUPLEX
DUPLEX
5.5mRd-X
ing
STAND ALONE NBNTRENCH - 19m
STAND ALONE NBNTRENCH - 22m
15m
PIT-0539
P1002.0
FDH-XXX
P1005.0
FDH-Cnr
FDH CONDUITCONTRACTOR SHALL INSTALL AND CAP100mm FDH CONDUIT FROM C9 FDH PIT
TO EDGE OF FUTURE FDH PLINTH.NBN CO WILL INSTALL VERTICAL BEND.
CIVIL CONTRACTORPLEASE ENSURE A 1m x 1m FLAT, LEVEL
SITE AT THE BACK OF THE VERGE,FOR THE NBN FIBRE DISTRIBUTION HUB.
GREAT SANDY CCT
GREAT SANDY CCT
MT ROYAL ST
KUMBATINE ST
MOWBRAY ST
GREAT SANDY CCT
BUTTERLEAF CR
BARAKEE ST
GREAT SANDY CCT
KOSCIUSZKO CCTKOSCIUSZKO CCT
GOLD COAST RAILWAY LINE
GOLD COAST RAILWAY LINE
MEBBIN ST
GREAT SANDY CCT
BUTTERLEAF CR
CONIMBLA ST
KOSCIUSZKO CCT
MEBBIN ST
KOSCIUSZKO CCT
P50
19.3
P100
23.0
P5017.1
P50 18.6
P50
29.8
P50
34.8
P5017.2
P50
17.6
P100
23.7
P100
34.1
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2014.0
P203.0
P2016.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P50
19.2
53
59
52
41 64
144
153
154
162
167139
36
31 74
129
134 172
177
179
26
79
EL (YE
LLOW
)
180
125
22
17
119
185
190
87
114
12
195
92
109
97
7
103
8
1
104
PIT-0585
PIT-0575
PIT-0565
PIT-0558
PIT-0632
PIT-0548
P100
46.8
P5047.
0
P10048.8
P100
63.6
P100
78.8
P100
12.0
P100
41.5
P203.0
P203.0
P203.0
P2012.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P1001.0
P1007.0
P100
39.0
P2023.0
PIT-0325
Development InformationDevelopment Name: Developer Company:
Authorised Rep:
Development Adress:
CRM ID: Stage Number:
Phone:E-Mail:
GAINSBOROUGH GREENS MIRVAC PACIFIC P/L
YAWALPAH ROAD, PIMPAMA
AYCA-2RECL1 PRECINCT 7.2A
TOM ALLISON07 3859 [email protected]
P100
63.5
P100
26.5
P100
22.4
P100
27.4
P50
31.8
P100
28.1
P100
26.4
P100
50.3
P100
31.5
P100
45.0
P100
33.6
P100
52.0
P100
47.0
P100
45.3
P100
34.6
P50
39.4
P100
35.9 P100
167.0
P100
27.2
P100
18.0P100
34.6
P50
50.7
P100
25.9
P5021.4
P100
30.5
P100
31.8
P100
40.1
P100
33.6
BILL OF MATERIAL
PITSSIZE2589
QTYDUCTS
SIZE QTY MTRSP100P50P23
TOTAL NUMBER OF PITS:TOTAL NUMBER OF CONDUITS:TOTAL LENGTH OF CONDUITS:
NO OF LOTS:
1231191
67 2102.415 409.379 327.0
631612838.7
76
96
97
98
99
77
78
79
330
PIT-0018
PIT-0028
PIT-0038
P1007.0
P100 17.0
P10019.1
P100
54.5
PIT-0528
P100
21.6
P100 35.9
103
PARK
102
101
88
89
90
91
92
93
94
95
80
81
82
83
84
85
86
87
68
69
70 71
EXISTING STAGE
DO NOT CONNECT TOANY EXISTING PITS OR
CONDUITS.
FLINDERS STGAINSBOROUGH
DRIVE
SALTWATER ST
WRAIGHT ST
KOSCIUSZKO CCT
MEBBIN ST
WRAIGHT ST
MEBBIN ST
PIT-0625
PIT-0615
PIT-0605
PIT-0598
PIT-0585
PIT-0575
PIT-0565
PIT-0558
PIT-0632
P100
48.8
P100
63.6
P100
36.4
P100
78.8
P10017.7
P2012.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2014.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2012.0
P1007.0
P2023.0
P100
63.5
P100
26.5
P100
22.4
P100
27.4P100
43.7
P100
28.8
P100
27.0
P5021.4
P100
39.6
ACCURATE OR COMPLETE.
DRAWING TITLE:
PROJECT No:
SCALE SHEET No. REV.
QUALITY RECORD :
APPROVED
NBNCO APPROVAL RECORD:
DD
AB
WD
REV DATE DESCRIPTION
SIGNATURE DATE
IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS.
USE OF NBNCO LIMITED (ABN 86 136 533 741)THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE
NBNCO DISCLAIMER
NO WARRANTY IS GIVEN THAT THE INFORMATION IS
FOR USE IN MAINTAINING NBNCO FACILITIES.IT HAS NOT BEEN CREATED FOR ANY OTHER USE.
CADREF No:
NN KEY PLAN
OF
LimitedFSA:
STATE: REGION:
FSAM:
DRAFTER
FDA:
**ATTENTION** CONSTRUCTORSDO NOT change or alter job
specifications unless first checkingwith designer.
MAP1
MAP3 MAP4
MAP2
SHEET1
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
Stafford, QLD 4053204/6 Babarra Street
Fax: (07) 3872 5566Tel: (07) 3872 5555
E: [email protected]& ASSOCIATES PTY. LTD.
Robin
Russell
CONSULTING ENGINEERS - ELECTRICAL
www.robrus.com.au
A.B.N. 78 010 589 661
GAINSBOROUGH GREENS PRECINCT 7.2C YAWALPAH ROADPIMPAMA
QLD
AYCA-3QMMPI
B580
1:1000 1 1 C
A 03/10/2016 SHANE MILLS ORIGINAL K.R.
B 21/02/2017 SHANE MILLS REVISED LOT BOUNDARIES 1215-1216 K.R.
C 31/10/2017 A.C. AS BUILT S.M.
LEGEND: NBN CONDUITS & PITS
Fibre Distribution Hub (FDH) site - 1m x 1m
Fibre Access Node (FAN) site
Local Network PitPremises Connection (Houses an MPT)Boundary PitCross-Road & Other Premises Connection (No MPT)Local Network Connection PitPremises Connection & Fibre Splice ClosureDistribution Pitat entry/exit to estate; @ 250m ccs on distribution conduit
Fibre Distribution Hub (FDH) PitWithin 5m of FDH Site
FAN(2ARM)
Marker Post(Post to be numbered)
FDH-ID576
RC183A 22 Multi Dwelling Unit (MDU)
Descriptor Box(Description of type of work & Quantity involved)
DESCQTY
T Existing Telstra conduit trench layout(Proposed conduit indicated for comms cable)
Existing or proposed Energex pole (& pole ID)ID-001
Existing Telstra Exchange
Existing Telstra Pits (size 2,3,4,5,6,7,8 or 9)
Existing Telstra Manholes (Access Chambers)
Existing Traffic Signals Box
Existing network item to be removed/replaced
TransformerPad Mount / Pole Mount
PWR
Depth over alignment indicator(used with every Marker Post)
Proposed 100mm Main Conduit
Proposed 23mm Service Drop
TRF
Proposed shared trench
Proposed 50mm Lateral Conduit
Proposed length of bored conduit
Service Drop Access Pit
Existing NBN 100mm conduit
Existing Telstra P100 conduit
DEPTH-ALIGN -_._
_._
5
M01
PIT-XXX2
PIT-XXX5
PIT-XXX5
PIT-XXX8
PIT-XXX8
PIT-XXX9
P100 40
P50 25
P23 7
'C' communications marker plate
COM
1200mm
LV
A
B
GROUND LEVEL
SECTION VIEW
TAPE
LOCATION A
MINIMUM CONDUIT DEPTH *
Verge 450mm
Local Road 600mm
DTMR Road 800mm
B
750mm
Energex 800mm; Ergon 900mm
LV
100m
m
SHARED TRENCH DETAIL-NBN
PROP
ERTY
BOU
NDAR
Y
* supercedes Energex/Ergon requirements
PIT
PIT
Property Boundary
Kerb
ROAD
NO PITS IN THE SHADED AREA
MIN. 3m MIN. 1m
MIN.
1mMI
N. 3m
ROADFOOTPATH
AS CONSTRUCTED
1174
1179
1180
1181
11821183
1184
1185
1186
1187
1188
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203120412051206
1207
1208
1209
1210
1211
1212
1213
1214
1178
1177
1189
1175
1176
1163
1164
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1107
1108
1155
1156
1157
1109
1110
1111
1112
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
PIT-0175
PIT-01
92
PIT-0205
PIT-0218
PIT-0395
PIT-0405
PIT-0415
PIT-0428
PIT-0535
PIT-0542 PIT-0455
PIT-0462 PIT-
0475
PIT-0485
PIT-0552
PIT-0505
PIT-0518
42.2
P10015.5
P100
33.7
P50
53.0
P100
39.6
P100
24.7
P100
P100
18.2
P100
40.0
P50
28.1
P1001.0
P10012.4
P100
26.2
P5017.3
P100
27.4
P100
26.7
P100
26.2
P100
18.6
P10013.7
P50
29.7
Development InformationDevelopment Name: Developer Company:
Authorised Rep:
Development Adress:
CRM ID: Stage Number:
Phone:E-Mail:
GAINSBOROUGH GREENS MIRVAC PACIFIC P/L
YAWALPAH ROAD, PIMPAMA
AYCA-3QMMPI PRECINCT 7.2C
TOM ALLISON07 3859 [email protected]
P203.0
P203.0
P203.0
P203.0
P203.0
P206.0
P2017.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2017.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P203.0
P2011.0
P203.0
P203.0
PIT-0539
P1002.0
P1004.7
P100
46.0
P100
24.6
19.2
PIT-00
15
PIT-00
25
PIT-00
35
PIT-00
45
PIT-0
055
PIT-0
065
PIT-0075PIT-00
82
PIT-0098
PIT-0108PIT-0118
PIT-0125
PIT-0132
PIT-0142
PIT-0155
PIT-0495
PIT-0
175
PIT-0
185
PIT-01
95
PIT-02
02
PIT-02
18
PIT-02
25
PIT-0238
PIT-0245
PIT-0252
PIT-0262
PIT-0275
PIT-0288
PIT-0295
PIT-0505
PIT-0315
PIT-0515
P100
19.7
P100
16
P100
31.7
P100
38
P100
39.6
P100
36.8
P100
34.4
P50
35.6P100
47
P100
31.9P100
45.1
P100
67.4
P10017.9
P50
33.5
P100
30
P5018.7
P100
29.3
P1001
P100
49.2
P100
66.3
P1001
P100
13.9
P100
23.6
P100
25.8
P5017.7
P100
27.9
P100
32.2
P1009.6
P100
48.1
P100
37.4
P50
29.3
P10017.3
P100
27.6
P100
16.9
P203
P2010
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P2015
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P10017.6
P50
30.2
P203
P203
P203
P2012
P203
P203
P203
P203
P203
P203
P203
CONNECT TO EXISTINGNBN CONDUIT
PIT-0015
PIT-0022
PIT-0
035
PIT-0
042
PIT-00
55
PIT-00
62
PIT-00
78
PIT-00
85
PIT-00
95
PIT-01
05
PIT-0
115
PIT-0
122
PIT-0
135
PIT-0
145
PIT-0
152
PIT-0
165
PIT-0175
PIT-0185
PIT-0195
PIT-0205
PIT-0
215
PIT-0
222
PIT-0
235
PIT-0
242
PIT-0255
PIT-02
65
PIT-02
75
PIT-02
82PIT
-030
8
PIT-0315
PIT-03
25
PIT-0
335
PIT-0
345
PIT-03
52
PIT-0365PIT-0372
PIT-03
8
8
PIT-03
9
5
PIT-04
02
PIT-0415
PIT-04
2
2
PIT-0435
PIT-0445
PIT-0452
PIT-0462
P50
36.4
P5017.4
P5020.2
P100
27.8
P5021.1
P100
21.8
P100
22.4
P100 27.9
P50
18.2
P10029.2
P100
19
P100
28.8
P50
21.4
P100
28.3
P100
66
P100
39
P5018.1
P100
44.4
PIT-0475
P100
47.8
P100
24.3
P100
41.7
P100
24.1
P100
25.4
P100
24.6
PIT-0485
P50
36.4
P100
26.4
P50 19.8
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203P20
3
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P2014
P203
P2014
P203
P203
P203
P203
P203
P203
P2016 P20
3
P203
P203
P203
P203
P203
P203
P203
P2016
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P2016
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P2020
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
P203
PIT-0525 P203
P100
43.9
P50
33.6
P203
P2020
P203
PWR
PWR
105310531061
1062
1063
1064
1065
1066
1067
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1106
1113
1128
1114
1115
1116
1117
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1172
1173
1174
1165
1166
1167
1158
1159
1160
1161
1162
1146
1147
1148
1149
1082
1083
1084
1085
1086
1087
1088
1089
1090
1139
1140
1141
1142
1143
1144
1145
1150
1151
1152
1153
1154
1168
1169
1170
1171
1080
1081
CONNECT TO EXISTINGNBN CONDUIT
CONNECT TO EXISTINGNBN CONDUIT
CONNECT TO EXISTINGNBN CONDUIT
CONNECT TO EXISTINGNBN CONDUIT
CONNECT TO EXISTINGNBN CONDUIT
CONNECT TO EXISTINGNBN CONDUIT
FDH-XXX
CONIMBLA
BUTTERFEAF CR
BARAKEE ST
BUTTERFEAF CR
GREAT
SANDY CCT
GREAT SANDY CCT
GREAT SANDY CCT
GREAT SANDY CCT
TOONUMBA ST
BUTTERLE
AF CRNANGAR ST
NANGAR ST
BUTTERFEAF CR
ST
GREAT SANDY CCT
GREAT SANDY CCT
GREAT SANDY CCT
GREAT SANDY CCT
SUND
OWN
CCT
SUND
OWN
CCT
(DUPLEX)
(DUPLEX)
906
DUPLEX
DUPLEX
DUPLEX
EXISTING PRECINCT 7.2ARR&A # B578AYCA-2RECL1
EXISTING PRECINCT 7.2BRR&A # B579AYCA-3QMMOS
STAND ALONE NBNTRENCH - 18m
@ 3m ALIGNMENT.
STAND ALONE NBNTRENCH - 26m
@ 3m ALIGNMENT.
STAND ALONE NBNTRENCH - 29m
@ 3m ALIGNMENT.
P203
P10015.3
P10013.8
P100
41
P50
13.1
P100
45.4
P100
49.8
P5035
P100
40.5
P50
36.6
P100
34.2
P100
24.1
P1009.3
P50
28.4
P100
16.2
P100
23.4
P100
16.6
P100
23.8
P100
63.1
P100
41.9
P5018.7
P100
36.4
P100
24.7
P10025.5
P100
34.1
P100
36.6
BILL OF MATERIAL
PITSSIZE2589
QTYDUCTS
SIZE QTY MTRSP100P50P23
TOTAL NUMBER OF PITS:TOTAL NUMBER OF CONDUITS:TOTAL LENGTH OF CONDUITS:
NO OF LOTS:
143230
38 1192.115 374.498 397
491511963.5
96