41
1 SEWON MEDIX 2014 PRODUCT CATALOG

SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

1

SEWON MEDIX 2014 PRODUCT CATALOG

Page 2: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

2

www.sewonmedix.com

SEWONMEDIX INC. Head office #369-16, Deokpo-dong, Sasang-gu, Busan, 617-814, Korea, Republic of

Page 3: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

3

T : +82-51-303-1713 / F : +82-51-303-1714 / E : [email protected]

Homepage : www.sewonmedix.com

Page 4: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

4

Contents

Introduction

Sewon Medix Prosthetics System Introduction

IH System

EH System

IO System

Manual

IH System

IH System Prosthetic Flow Diagrams

Solid Abutment Components

Cemented Abutment Components

Angled Abutment Components

Multi-unit Components

EH System

EH System Prosthetic Flow Diagrams

Cemented Abutment Components

UCLA CCM Abutment Components

Angled Abutment Components

Multi-unit Components

IO System

IO System Prosthetic Flow Diagrams

Solid Abutment Components

Cemented Abutment Components

Angled Abutment Components

Octa Abutment Components

Multi-unit Components

KIT

Prosthetic Kit (being drafted)

Page 5: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

Introduction

IH System

• Internal hex & 11° Morse taper connection (Submerged type)

• cement retained restoration & screw-retained restoration

Page 6: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

6

Introduction

EH System

• External hex connection (Submerged type)

• cement retained restoration & screw-retained restoration

Page 7: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

7

Introduction

IO System

• Internal octa & Morse taper connection (non-Submerged type)

• cement retained restoration & screw-retained restoration

Page 8: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

8

Instructions for Use

1. PREPARATION 1) Asepsis operation room and aseptic clothing should be prepared. 2) Operators need to be well aware of the treatment plan, operating methods

concerning the product, clinical indications and cautions. 3) Operators should verify the dental hygiene of patients and make a plan

after diagnosis of the existence of biological and physiological factors that

affect the result. 4) Through X-ray and close observation, operators should verify if Fixture’s

osseointegration is appropriate for treatment. 5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw

bones and shape need to be considered for each patient. 6) Defect and abnormality of the product should be examined before the use,

and the product with overdue expiration date must not be used. 7) The packing should be opened when used and applied to a patient, and

when defect or abnormality is found, the product should not be used. 2. INSTRUCTINONS FOR USE 1) After recovering soft tissue(When use in One Stage surgery, it can be used

immediately after the removal of the healing abutment), the impression can

be obtained. 2) Compare the X-ray photos and the impression, and consider the adjacent

teeth, then the abutment model and size can be decided. 3) The product should be sterilized in an autoclave at 132℃ for minimum 15

minutes and dried for minimum 15 minutes. 4) The selected abutment is mounted to the fixation. 5) The impression needs to be obtained when the abutment is mounted, then

the final prosthetic is made. 6) For the Cement Retained Type, wax-up needs to be done on the abutment

using the plaster model, then the prosthetic is made. 7) The final prosthetic is set at the abutment or the planted platform and the

occlusion of the upper and lower jawbone should be identified, then the

prosthetic is completed. 8) The recommended torque for the screw is as follows: - Cylinder screw: 20N·cm - Abutment screw: 30N·cm 3. CAUTIONS 1) Inappropriate patient selection or procedure may harm on implant devices

or on adjacent osseous tissues, therefore, specialized doctor’s treatment is

required. 2) Re-use of the product may cause inflammation, failure of implant

osseointegration, prosthetic damage.

3) The product should be applied as of the purpose of the product, and the

defect or the damaged products should be replaced. 4) The product should be handled with care to prevent deformation or

damage. 5) The product should be handled under the aseptic environment with aseptic

clothing. 4. PROHIBITION 1) Treatment on patients who may cause instability on the implants, the

fixation failure or complications etc, due to patient’s psychological or physical

disabilities. 2) Treatment on patients with and acute disease such as cardiac seizure

history, arteriosclerosis,etc. 3) Treatment on patients under the status of influencing on osseous tissue

formation, microcirculation or on blood. 4) Patients in pregnancy 5) Patients with uncontrolled high blood pressure or diabetes. 6) Patients with no consent 7) Patients with significantly lower immunity due to chemo or radio therapy. 8) Patients with excessive tobacco smoking or alcohol drinking. 9) Patients with inappropriate dental hygiene. 5. SIDE EFFECTS 1) Dehiscence, healing delay, anesthetic edema 2) Hematoma, infection, inflammation 3) General hypersensitive reaction 6. NOTICE 1) The product should be sterilized before applying to a patient. 2) When the final prosthetic is fixed, osseointegration by X-ray or by stability

test should be executed to verify. 3) Abutment screw fixation should follow the appropriate range of torque

suggested in the MANUAL FOR USE. Excessive torque, may damage the driver,

any function parts or the screw, and less torque than minimum may cause

loosening. 4) When the screw is fixed with Fixture, the fixing direction should be aligned

to the same direction, and over-pressure should not be applied until the firm

fixation is verified. When the fixation is not verified, the product may be

damaged. 5) The product is single-service product and should not be re-used. 6) Patients need to be careful not to apply over-masticatory pressure and

maintain clean dental hygiene.

SewonMedix Inc. 29, Sasang-ro 375beon-gil, Sasang-Gu, Busan,

Republic of Korea. (617-814)

Tel : +82-303-1713 Fax : +82-51-303-1714

www.sewonmedix.com

DongBang Acuprime

1 The Forrest Units, Hennock Road East,

Marsh Barton, Exeter EX2 8RU, U.K

Tel : +44 1392 829500 Fax: +44 1392 823232

Do not reuse

CAUTION

Manufacturer

EC Representative

NON STERILE

Consult Instructions for Use

Lot No.

Catalogue No.

Temperature

limitation Use by

Page 9: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

2

SEWON MEDIX SYSTEM IH Prosthetic System

Page 10: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

3

IH SYSTEM

007 IH System Prosthetic Flow Diagrams

010 Solid Abutment Components

020 Cemented Abutment Components

030 Angled Abutment Components

040 Multi-unit Abutment Components

Page 11: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

4

Prosthetic Flow Diagram for IH System Cement Retained Restoration - Solid & Cemented Abutment

Compatible with 11° Taper Internal Connection

Solid Lab Analog

Protect Cap

1.2 Hex Driver Solid Abutment Cemented Abutment 1.2 Hex Driver

Page 12: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

5

OSSTEM / DENTIUM / DENTIS / MEGAGEN / DIO / NEOBIOTECH

Prosthetic Flow Diagram for IH System Cement Retained Restoration - Cemented & Angled Abutment

Screw Retained Restoration – Temporary Abutment

Ti Abutment Screw 1.2 Hex Driver

Cemented Abutment [Hex] [Non-Hex]

Angled Abutment [A-type] [B-type] [Non-Hex]

Fixture Lab Analog

Pick-up Impression Coping [Hex] [Non-Hex] [Hex] [Non-Hex]

Transfer Impression Coping

Temporary Abutment [Hex] [Non-Hex]

Page 13: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

6

Prosthetic Flow Diagram for IH System Screw Retained Restoration – Multi-unit Abutment

Multi-unit Temporary Cylinder

Ti- Screw

Multi-unit CCM Cylinder Multi-unit Plastic Cylinder

Multi-unit Lab Analog

Multi-unit Pick-up Impression Coping Multi-unit Transfer Impression Coping

Multi-unit Abutment Screw(Star)

Multi-unit Abutment Star Driver

1.2 Hex Driver

1.2 Hex Driver

1.2 Hexr Driver

Page 14: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

7

Page 15: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

8

IH2 RBM Fixture

Feature of IH2 RBM Fixture

• Internal hex & conical connection, submerged type implant

• RBM(Resorbable Blast Media) surface(Ra:1.5~2.0㎛)

• Taper body offers high initial stability

• Self tapping skills

• Limited insertion torque : 40Ncm

We recommend that the fixture with over 4.5mm diameter is used for single case in Molar.

• Set order code : Fixture + Cover screw = A+Product code (ex : AIH2FR4011)

X 5,000

Page 16: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

9

IH2 RBM Fixture Mini

Mini Ø3.5 D L

Ø3.5

8.5 IH2FM3508R

10.0 IH2FM3510R

11.5 IH2FM3511R

13.0 IH2FM3513R

15.0 IH2FM3515R

Regular

Regular Ø4.0 D L

Ø4.0

8.5 IH2FR4008R

10.0 IH2FR4010R

11.5 IH2FR4011R

13.0 IH2FR4013R

15.0 IH2FR4015R

Regular

Ø4.5 D L

Ø4.5

8.5 IH2FR4508R

10.0 IH2FR4510R

11.5 IH2FR4511R

13.0 IH2FR4513R

15.0 IH2FR4515R

Regular

Ø5.0 D L

Ø5.5

8.5 IH2FR5008R

10.0 IH2FR5010R

11.5 IH2FR5011R

13.0 IH2FR5013R

15.0 IH2FR5015R

L

D

L

D

L

D

L

D

Page 17: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

10

Cover screw Fixture Mini Regular

Color Purple Green

Code IHCSM IHCSR

• Packing unit : Lab Analog

• Use the 1.2 Hex Driver

Healing Abutment H

D 3.0 5.0 7.0

Mini Ø4.0 / Ø4.5

Ø4.0 IHHAM403 IHHAM405 IHHAM407

Ø4.5 IHHAM453 IHHAM455 IHHAM457

Regular Ø4.5 / Ø5.0 / Ø5.5 H

D 3.0 5.0 7.0

Ø4.5 IHHAR453 IHHAR455 IHHAR457

Ø5.0 IHHAR503 IHHAR505 IHHAR507

Ø5.5 IHHAR553 IHHAR555 IHHAR557

Ø6.0 / Ø6.5 H D

3.0 5.0 7.0

Ø6.0 IHHAR603 IHHAR605 IHHAR607

Ø6.5 IHHAR653 IHHAR655 IHHAR657

H

H

D

H

D

D

Page 18: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

11

IH Solid Abutment Components

Solid Abutment H

D G/H

Ø4.0 Ø4.5 Cement-retained restoration

Mini

Ø4.0 / Ø4.5

4.0

1.0 IHSAM4010S IHSAM4510S

2.0 IHSAM4020S IHSAM4520S

3.0 IHSAM4030S IHSAM4530S

4.0 IHSAM4040S IHSAM4540S

5.0 IHSAM4050S IHSAM4550S

5.5

1.0 IHSAM4010M IHSAM4510M

2.0 IHSAM4020M IHSAM4520M

3.0 IHSAM4030M IHSAM4530M

4.0 IHSAM4040M IHSAM4540M

5.0 IHSAM4050M IHSAM4550M

7.0

1.0 IHSAM4010L IHSAM4510L

2.0 IHSAM4020L IHSAM4520L

3.0 IHSAM4030L IHSAM4530L

4.0 IHSAM4040L IHSAM4540L

5.0 IHSAM4050L IHSAM4550L

• Packing unit : Solid abutment + Protect cap

• Use the 1.2 Hex Driver(Ø4.0 use the Solid outer driver)

• Screw torque : 30Ncm

• Set order code : Abutment + Protect cap = A+Product code (ex : AIHSAM4010S)

D

H

G/H

Page 19: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

12

Regular

Ø4.5 / Ø5.0 / Ø5.5

H D

G/H Ø4.5 Ø5.0 Ø5.5

4.0

1.0 IHSAR4510S IHSAR5010S IHSAR5510S

2.0 IHSAR4520S IHSAR5020S IHSAR5520S

3.0 IHSAR4530S IHSAR5030S IHSAR5530S

4.0 IHSAR4540S IHSAR5040S IHSAR5540S

5.0 IHSAR4550S IHSAR5050S IHSAR5550S

5.5

1.0 IHSAR4510M IHSAR5010M IHSAR5510M

2.0 IHSAR4520M IHSAR5020M IHSAR5520M

3.0 IHSAR4530M IHSAR5030M IHSAR5530M

4.0 IHSAR4540M IHSAR5040M IHSAR5540M

5.0 IHSAR4550M IHSAR5050M IHSAR5550M

7.0

1.0 IHSAR4510L IHSAR5010L IHSAR5510L

2.0 IHSAR4520L IHSAR5020L IHSAR5520L

3.0 IHSAR4530L IHSAR5030L IHSAR5530L

4.0 IHSAR4540L IHSAR5040L IHSAR5540L

5.0 IHSAR4550L IHSAR5050L IHSAR5550L

Regular

Ø6.0 / Ø6.5

H D

G/H Ø6.0 Ø6.5

4.0

1.0 IHSAR6010S IHSAR6510S

2.0 IHSAR6020S IHSAR6520S

3.0 IHSAR6030S IHSAR6530S

4.0 IHSAR6040S IHSAR6540S

5.0 IHSAR6050S IHSAR6550S

5.5

1.0 IHSAR6010M IHSAR6510M

2.0 IHSAR6020M IHSAR6520M

3.0 IHSAR6030M IHSAR6530M

4.0 IHSAR6040M IHSAR6540M

5.0 IHSAR6050M IHSAR6550M

7.0

1.0 IHSAR6010L IHSAR6510L

2.0 IHSAR6020L IHSAR6520L

3.0 IHSAR6030L IHSAR6530L

4.0 IHSAR6040L IHSAR6540L

5.0 IHSAR6050L IHSAR6550L

• Packing unit : Solid abutment + Protect cap

• Use the 1.2 Hex Driver

• Screw torque : 30Ncm

• Set order code : Abutment + Protect cap = A+Product code (ex : AIHSAR5020S)

D

H

G/H

D

H

G/H

Page 20: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

13

Solid protect Cap

Mini / Regular

D

H Ø4.0 Ø4.5

4.0 IHPC40S IHPC45S

5.5 IHPC40M IHPC45M

7.0 IHPC40L IHPC45L

Regular

D

H Ø5.0 Ø5.5 Ø6.0 Ø6.5

4.0 IHPC50S IHPC55S IHPC60S IHPC65S

5.5 IHPC50M IHPC55M IHPC60M IHPC65M

7.0 IHPC50L IHPC55L IHPC60L IHPC65L

• Packing unit : Protect cap

• Locking function

Solid Lab Analog

Mini / Regular

D

H Ø4.0 Ø4.5

4.0 IHSLA40S IHSLA45S

5.5 IHSLA40M IHSLA45M

7.0 IHSLA40L IHSLA45L

Regular

D

H Ø5.0 Ø5.5 Ø6.0 Ø6.5

4.0 IHSLA50S IHSLA55S IHSLA60S IHSLA65S

5.5 IHSLA50M IHSLA55M IHSLA60M IHSLA65M

7.0 IHSLA50L IHSLA55L IHSLA60L IHSLA65L

• Packing unit : Lab analog

D

H

D

H

Page 21: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

14

IH Cement Abutment Components

Cement Abutment H

D G/H

Ø4.5

Cement-retained restoration Hex Non-Hex

Mini

Ø4.5

5.5

1.0 IHCAMH4510M IHCAMN4510M

2.0 IHCAMH4520M IHCAMN4520M

3.0 IHCAMH4530M IHCAMN4530M

4.0 IHCAMH4540M IHCAMN4540M

5.0 IHCAMH4550M IHCAMN4550M

Abutment screw IHASM

• Packing unit : Cement Abutment + Abutment screw

• Use the1.2 Hex driver

• Screw torque : 20Ncm

• Set order code : Abutment + Abutment screw = A+Product code (ex : AIHCAMH4510S)

D

H

G/H

Hex Non-Hex

Page 22: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

15

Regular

Ø4.5

H D

G/H

Ø4.5

Hex Non-Hex

5.5

1.0 IHCARH4510M IHCARN5010M

2.0 IHCARH4520M IHCARN5020M

3.0 IHCARH4530M IHCARN5030M

4.0 IHCARH4540M IHCARN5040M

5.0 IHCARH4550M IHCARN5050M

Abutment screw IHASR

Ø5.0

H D

G/H

Ø5.0

Hex Non-Hex

4.0

1.0 IHCARH5010S IHCARN5010S

2.0 IHCARH5020S IHCARN5020S

3.0 IHCARH5030S IHCARN5030S

4.0 IHCARH5040S IHCARN5040S

5.0 IHCARH5050S IHCARN5050S

5.5

1.0 IHCARH5010M IHCARN5010M

2.0 IHCARH5020M IHCARN5020M

3.0 IHCARH5030M IHCARN5030M

4.0 IHCARH5040M IHCARN5040M

5.0 IHCARH5050M IHCARN5050M

7.0

1.0 IHCARH5010L IHCARN5010L

2.0 IHCARH5020L IHCARN5020L

3.0 IHCARH5030L IHCARN5030L

4.0 IHCARH5040L IHCARN5040L

5.0 IHCARH5050L IHCARN5050L

• Packing unit : Cement abutment + Abutment screw

• Use the 1.2 Hex Driver

• Screw torque : 30Ncm

• Set order code : Abutment + Abutment screw = A+Product code (ex : AIHCARH5020S)

D

H

G/H

Hex Non-Hex

D

H

G/H

Page 23: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

2

Regular

Ø5.5

H D

G/H

Ø5.5

Hex Non-Hex

4.0

1.0 IHCARH5510S IHCARN5510S

2.0 IHCARH5520S IHCARN5520S

3.0 IHCARH5530S IHCARN5530S

4.0 IHCARH5540S IHCARN5540S

5.0 IHCARH5550S IHCARN5550S

5.5

1.0 IHCARH5510M IHCARN5510M

2.0 IHCARH5520M IHCARN5520M

3.0 IHCARH5530M IHCARN5530M

4.0 IHCARH5540M IHCARN5540M

5.0 IHCARH5550M IHCARN5550M

7.0

1.0 IHCARH5510L IHCARN5510L

2.0 IHCARH5520L IHCARN5520L

3.0 IHCARH5530L IHCARN5530L

4.0 IHCARH5540L IHCARN5540L

5.0 IHCARH5550L IHCARN5550L

Abutment screw IHASR

Ø6.0

H D

G/H

Ø6.0

Hex Non-Hex

4.0

1.0 IHCARH6010S IHCARN6010S

2.0 IHCARH6020S IHCARN6020S

3.0 IHCARH6030S IHCARN6030S

4.0 IHCARH6040S IHCARN6040S

5.0 IHCARH6050S IHCARN6050S

5.5

1.0 IHCARH6010M IHCARN6010M

2.0 IHCARH6020M IHCARN6020M

3.0 IHCARH6030M IHCARN6030M

4.0 IHCARH6040M IHCARN6040M

5.0 IHCARH6050M IHCARN6050M

7.0

1.0 IHCARH6010L IHCARN6010L

2.0 IHCARH6020L IHCARN6020L

3.0 IHCARH6030L IHCARN6030L

4.0 IHCARH6040L IHCARN6040L

5.0 IHCARH6050L IHCARN6050L

• Packing unit : Cement abutment +Abutment screw

• Use the 1.2 Hex Driver

• Screw torque : 30Ncm

• Set order code : Abutment + Abutment screw = A+Product code (ex : AIHCARH5020S)

Hex Non-Hex

D

H

G/H

D

H

G/H

Page 24: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

3

Regular

Ø6.5

H D

G/H

Ø6.5

Hex Non-Hex

4.0

1.0 IHCARH6510S IHCARN6510S

2.0 IHCARH6520S IHCARN6520S

3.0 IHCARH6530S IHCARN6530S

4.0 IHCARH6540S IHCARN6540S

5.0 IHCARH6550S IHCARN6550S

5.5

1.0 IHCARH6510M IHCARN6510M

2.0 IHCARH6520M IHCARN6520M

3.0 IHCARH6530M IHCARN6530M

4.0 IHCARH6540M IHCARN6540M

5.0 IHCARH6550M IHCARN6550M

7.0

1.0 IHCARH6510L IHCARN6510L

2.0 IHCARH6520L IHCARN6520L

3.0 IHCARH6530L IHCARN6530L

4.0 IHCARH6540L IHCARN6540L

5.0 IHCARH6550L IHCARN6550L

Abutment screw IHASR

• Packing unit : Cement abutment +Abutment screw

• Use the 1.2 Hex Driver

• Screw torque : 30Ncm

• Set order code : Abutment + Abutment screw = A+Product code (ex : AIHCARH6520S)

Non-Hex Hex

D

H

G/H

Page 25: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

4

Fixture Lab Analog Mini Regular

Code IHFLAM IHFLAR

• Packing unit : Lab Analog

Fixture pick-up impression coping

Mini

L D

Type Ø4.0

11 Hex IHPIMH4011

Non-Hex IHPIMN4011

Guide Pin

(H) 0 - IHPIGPM100

5.0 - IHPIGPM150L

15 Hex IHPIMH4015

Non-Hex IHPIMN4015

Guide Pin

(H) 0 - IHPIGPM150

5.0 - IHPIGPM190L

Regular L D

Type Ø4.5 Ø5.0 Ø6.0

11 Hex IHPIRH4511 IHPIRH5011 IHPIRH6011

Non-Hex IHPIRN4511 IHPIRN5011 IHPIRN6011

Guide Pin

(H) 0 - IHPIGPR100

5.0 - IHPIGPR150L

15 Hex IHPIRH4515 IHPIRH5015 IHPIRH6015

Non-Hex IHPIRN4515 IHPIRN5015 IHPIRN6015

Guide Pin

(H) 0 - IHPIGPR140

5.0 - IHPIGPR190L

• Packing unit : Impression coping body +Guide pin

• Use the 1.2 Hex Driver

• Pick-up type for taking an impression using a customized tray

L

11 15 D

H

L

H

11 15

D

Page 26: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

5

Fixture Transfer impression coping

Mini

Regular

L D

Type Ø4.0

11 Hex IHTIMH4011

Non-Hex IHTIMN4011

14 Hex IHTIMH4014

Non-Hex IHTIMN4014

L D

Type Ø4.5 Ø5.0

11 Hex IHTIRH4511 IHTIRH5011

Non-Hex IHTIRN4511 IHTIRN5011

14 Hex IHTIRH4514 IHTIRH5014

Non-Hex IHTIRN4514 IHTIRN5014

L D

Type Ø6.0 Ø7.0

11 Hex IHTIRH6011 IHTIRH7011

Non-Hex IHTIRN6011 IHTIRN7011

14 Hex IHTIRH6014 IHTIRH7014

Non-Hex IHTIRN6014 IHTIRN7014

• Packing unit : Impression coping body + Guide pin[Hex type]

Impression coping[Non-Hex type]

• Use the 1.2 Hex Driver

• Transfer type for taking an impression using a ready-made tray

• Hex type Two-piece, Non-Hex type One-piece

D

L

aHex Non-Hex

11 14

Hex Non-Hex

D

L

Hex Non-Hex

11 14

Hex Non-Hex

Page 27: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

6

Temporary Abutment

Mini

Regular

G/H D

Type Ø4.0

1.0 Hex IHTAMH4010

Non-Hex IHTAMN4010

3.0 Hex IHTAMH4030

Non-Hex IHTAMN4030

Abutment Screw IHASM

L D

Type Ø4.5

1.0 Hex IHTARH4510

Non-Hex IHTARN4510

3.0 Hex IHTARH4530

Non-Hex IHTARN4530

Abutment Screw IHASR

• Packing unit : Temporary abutment + Abutment screw

• Use the 1.2 Hex Driver

• Screw torque : 15Ncm

D

G/H

D

G/H

Page 28: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

7

Angled Abutment

Mini

Regular

Ø5.0

G/H D

Type

Ø4.5

15° 25°

2.0

Hex_A-type IHAAMA452015 IHAAMA452025

Hex_B-type IHAAMB452015 IHAAMB452025

Non-Hex IHAAMN452015 IHAAMN452025

3.0

Hex_A-type IHAAMA453015 IHAAMA453025

Hex_B-type IHAAMB453015 IHAAMB453025

Non-Hex IHAAMN453015 IHAAMN453025

4.0

Hex_A-type IHAAMA454015 IHAAMA454025

Hex_B-type IHAAMB454015 IHAAMB454025

Non-Hex IHAAMN454015 IHAAMN454025

Abutment Screw IHASM

G/H D

Type

Ø5.0

15° 25°

2.0

Hex_A-type IHAAMA502015 IHAAMA502025

Hex_B-type IHAAMB502015 IHAAMB502025

Non-Hex IHAAMN502015 IHAAMN502025

3.0

Hex_A-type IHAAMA503015 IHAAMA503025

Hex_B-type IHAAMB503015 IHAAMB503025

Non-Hex IHAAMN503015 IHAAMN503025

4.0

Hex_A-type IHAAMA504015 IHAAMA504025

Hex_B-type IHAAMB504015 IHAAMB504025

Non-Hex IHAAMN504015 IHAAMN504025

Abutment Screw IHASR

• Packing unit : Angled abutment + Abutment screw

• Use the 1.2 Hex Driver

• Screw torque : 20Ncm(mini), 30Ncm(regular)

D

G/H

15 25

A type B type Non-Hex type

G/H

15 25

A type B type Non-Hex type D

Page 29: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

8

Regular

Ø5.5 / Ø6.0

G/H D

Type

Ø5.5

15° 25°

2.0

Hex_A-type IHAAMA552015 IHAAMA552025

Hex_B-type IHAAMB552015 IHAAMB552025

Non-Hex IHAAMN552015 IHAAMN552025

3.0

Hex_A-type IHAAMA553015 IHAAMA553025

Hex_B-type IHAAMB553015 IHAAMB553025

Non-Hex IHAAMN553015 IHAAMN553025

4.0

Hex_A-type IHAAMA554015 IHAAMA554025

Hex_B-type IHAAMB554015 IHAAMB554025

Non-Hex IHAAMN554015 IHAAMN554025

G/H D

Type

Ø6.0

15° 25°

2.0

Hex_A-type IHAAMA602015 IHAAMA602025

Hex_B-type IHAAMB602015 IHAAMB602025

Non-Hex IHAAMN602015 IHAAMN602025

3.0

Hex_A-type IHAAMA603015 IHAAMA603025

Hex_B-type IHAAMB603015 IHAAMB603025

Non-Hex IHAAMN603015 IHAAMN603025

4.0

Hex_A-type IHAAMA604015 IHAAMA604025

Hex_B-type IHAAMB604015 IHAAMB604025

Non-Hex IHAAMN604015 IHAAMN604025

Abutment Screw IHASR

• Packing unit : Angled abutment + Abutment screw

• Use the 1.2 Hex Driver

• Screw torque : 30Ncm

15 25

A type B type Non-Hex type

D

G/H

Page 30: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

9

IH Multi-unit Abutment Components

Multi-unit Abutment Screw retained restoration

A

G/H

17°

Hex Non-Hex

2.5 IHMARH2517 IHMARN2517

3.5 IHMARH3517 IHMARN3517

30°

3.5 IHMARH3530 IHMARN3530

4.5 IHMARH4530 IHMARN4530

Abutment Screw IHMASR200

• Packing unit : Multi-unit abutment + Abutment screw

• Use the 1.2 Hex Driver

• Screw torque : 30Ncm

Healing Cap

D

H Ø4.8

5.0 MHC480

• Packing unit : Healing cap

• Use the 1.2 Hex Driver

• Screw torque : 20Ncm

• Use for the healing cap of the multi-unit abutment on the oral cavity and to

minimize the patient's discomfort.

Hex Non-Hex

17°

Hex Non-Hex

30°

G/H

H

D

Page 31: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

10

CCM Cylinder

D

H Ø4.8

12.0 MCC100

Cylinder Screw CS200

• Packing unit : CCM cylinder + Cylinder screw

• Use the 1.2 Hex Driver

• Screw torque : 20Ncm

• The prosthesis is made of Alloy Casting

Plastic Cylinder

D

H Ø4.8

12.0 MPC100

Cylinder Screw CS200

• Packing unit : Plastic cylinder + Cylinder screw

• Use the 1.2 Hex Driver

• Screw torque : 20Ncm

• The prosthesis is made of Alloy Casting.

H

D

H

D

Page 32: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

11

Temporary Cylinder

D

H Ø4.8

12.0 MTC100

Cylinder Screw CS200

• Packing unit : Temporary cylinder + Cylinder screw

• Use the 1.2 Hex Driver

• Screw torque : 15Ncm

• Multi-unit Abutment used in the making of a temporary prosthesis

Transfer Impression Coping

D

H Ø4.8

8.0 MTIC480

• Packing unit : Impression coping

• Multi-unit abutment only preliminary impression coping

• Transfer type for taking an impression using a ready-made tray

H

D

D

H

Page 33: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

12

Pick-up Impression Coping

D

H Ø4.8

8.0 MPIC480

Guide Pin MTIGP120

• Packing unit : Impression coping body + Guide pin

• Use the 1.2 hex Driver

• Final impression coping only for Multi-unit Abutment

• Pick-up type for taking an impression using a customized tray

Lab Analog

Code MLA480

• Packing unit : Lab analog

• Make Multi-unit abutment on a working model

D

H

Page 34: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

13

Multi-unit Abutment System Prosthetic Flow Diagrams for Multi-unit Abutment

Multi-unit Temporary Cylinder

Ti- Screw

Multi-unit CCM Cylinder

Multi-unit Plastic Cylinder

Multi-unit Temporary Cylinder

Multi-unit Pick-up Impression Coping

Multi-unit Transfer Impression Coping

Multi-unit Abutment Screw(TG)

Multi-unit Abutment TG Driver

Hex Driver

Page 35: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

14

Multi-unit Abutment screw-retained restorations

•Implant fixing angle can be adjusted with simple prosthetic.

•Handles will be provided with abutments for guidance of correct seating.

•Collar height and angle (17°or 30°), Hex or Non-Hex can be selected.

※Note:

1) We do not recommend 30°Multi-unit Abutment for fixture of Mini size.

2) 25~30N/cm of screw torque for abutment screw is recommended.

Page 36: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

15

EH Multi-unit AbutmentComponents

Multi-unit Abutment

Mini

Angle G/H Hex Non-Hex

17°

2.0 EHMAMH1720 EHMAMN1720

3.0 EHMAMH1730 EHMAMN1730

Regular

• Packing unit : Abutment + Ti Screw

• Screw-retained restorations prosthetic

•Use the Triangle(TG)driver

•Screw torque : 30Ncm

Angle G/H Hex type Non-Hex type

17°

2.0 EHMARH1720 EHMARN1720

3.0 EHMARH1730 EHMARN1730

4.0 EHMARH1740 EHMARN1740

30° 4.0 EHMARH3040 EHMARN3040

5.0 EHMARH3050 EHMARN3050

Ø4.8

30°

G/H

Ø4.8

17°

G/H

G/H

Ø4.1

Ø3.5

G/H

Page 37: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

16

Multi-unit Healing Cap

Multi-unit CCM Cylinder

Multi-unit Plastic Cylinder

D

H Ø4.8

5.0 MHC480

• Packing unit : Healing Cap

•Use for the healing cap of the multi-unit abutment on the

oral cavity and to minimize the patient's discomfort.

•Use the 1.2 hex driver

•Screw torque : 20Ncm

D

H Ø4.8

12.0 MCC100

• Packing unit : Cylinder + Ti Screw

•The prosthesis is made of Alloy Casting.

•Use the 1.2 hex driver

•Screw torque : 20Ncm

D

H Ø4.8

12.0 MPC100

• Packing unit : Cylinder + Ti Screw

•The prosthesis is made of Alloy Casting.

•Use the 1.2 hex driver

•Screw torque : 20Ncm

1.2

H

D

H

1.2

D

H

1.2

D

Page 38: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

17

Multi-unit Temporary Cylinder

Multi-unit Transfer Impression Coping

Multi-unit Pick-up Impression Coping

D

H Ø4.8

12.0 MTC100

• Packing unit : Cylinder + Ti Screw

•Multi-unit Abutment used in the making of a temporary

prosthesis

• Use the 1.2 hex driver

•Screw torque : 15Ncm

D

H Ø4.8

8.0 MTIC480

• Packing unit : Impression Coping

•Multi-unit Abutment only preliminary impression coping

•Transfer typefor taking an impression using a ready-made

tray

D

H Ø4.8

8.0 MPIC480

• Packing unit : Impression coping body + Guide Screw

•Final impression coping only for Multi-unit Abutment

• Pick-up type for taking an impression using a customized

tray

•Use the 1.2 hex Driver

H

1.2

D

H

D

1.2

D

H

Page 39: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

18

Multi-unit Lab Analog

Code MLA480

• Packing unit : Lab analog

•Make Multi-unit abutment on a working model

Page 40: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

19

Instruments

Machine Screw Driver

Torque Driver

Ratchet Driver

Type Short(6mm) Long(11mm)

Hex Star

Hex MHD12S MHD12L

Triangle MTD12S MTD12L

• Packing unit :Machine Screw Driver

•Holding function

•Used with engine

Type Short(10mm) Long(15mm)

Hex Star

Hex THD12S THD12L

Triangle TTD12S TTD12L

• Packing unit :Torque Driver

•Holding function

•Torque wrench driver

Type Short(10mm) Long(15mm)

Hex Star

Hex RHD12S RHD12L

Star RTD12S RTD12L

• Packing unit : Torque Driver

•Holding function

•Rarchet wrench driver

L

L

L

Page 41: SEWON MEDIX - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h3e/...5) Planted Fixture’s size, height of soft tissue, gradient, distance between jaw bones and shape

20

Driver Handle

Code ATDHS

• Packing unit : Driver Handle

•Used by connecting with Torque Driver