Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
ASMB-LEServer Management Board
i ii ii ii ii i
E1743E1743E1743E1743E1743
First edit ion V1First edit ion V1First edit ion V1First edit ion V1First edit ion V1November 2004November 2004November 2004November 2004November 2004
Copyright © 2004 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and software described in it, may be reproduced,transmitted, transcribed, stored in a retrieval system, or translated into any language in any formor by any means, except documentation kept by the purchaser for backup purposes, without theexpress written permission of ASUSTeK COMPUTER INC. (“ASUS”).
Product warranty or service will not be extended if: (1) the product is repaired, modified oraltered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2)the serial number of the product is defaced or missing.
ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHEREXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIESOR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.IN NO EVENT SHALL ASUS, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BELIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES(INCLUDING DAMAGES FOR LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USEOR DATA, INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS BEENADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT ORERROR IN THIS MANUAL OR PRODUCT.
SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHEDFOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIMEWITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS.ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS ORINACCURACIES THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTSAND SOFTWARE DESCRIBED IN IT.
Products and corporate names appearing in this manual may or may not be registeredtrademarks or copyrights of their respective companies, and are used only for identification orexplanation and to the owners’ benefit, without intent to infringe.
i i ii i ii i ii i ii i i
Contents
Contents ............................................................................................. iii
Notices ................................................................................................. v
Safety information .............................................................................. vi
About this guide ................................................................................ vii
Typography ....................................................................................... viii
ASMB-LE specifications summary ....................................................... ix
Chapter 1:Chapter 1:Chapter 1:Chapter 1:Chapter 1: Product introductionProduct introductionProduct introductionProduct introductionProduct introduction
1.1 Welcome! .............................................................................. 1-2
1.2 Package contents ................................................................. 1-2
1.3 Board layout ......................................................................... 1-3
1.4 System requirements ........................................................... 1-3
1.5 Network setup ...................................................................... 1-4
Chapter 2:Chapter 2:Chapter 2:Chapter 2:Chapter 2: Instal lationInstal lationInstal lationInstal lationInstal lation
2.1 Before you proceed .............................................................. 2-2
2.2 Hardware installation ............................................................ 2-2
2.3 Network configuration .......................................................... 2-5
2.3.1 Running the ASMC utility ........................................ 2-5
2.3.2 Configuring the LAN controller ............................... 2-6
2.3.3 Updating the ASMC-LE firmware ............................ 2-8
2.4 Software installation ............................................................ 2-9
2.4.1 Installing the ARC ................................................... 2-9
2.4.2 Launching ARC...................................................... 2-10
Chapter 3:Chapter 3:Chapter 3:Chapter 3:Chapter 3: Software supportSoftware supportSoftware supportSoftware supportSoftware support
3.1 ASUS Remote Console (ARC) ............................................... 3-2
3.1.1 ARC sections .......................................................... 3-2
3.1.2 Connecting to the remote server ........................... 3-5
3.1.3 Retrieving sensor information ................................. 3-7
3.1.4 Displaying all remote server sensors ...................... 3-9
3.1.5 Displaying FRU information ................................... 3-10
3.1.6 Displaying system event logs ............................... 3-11
3.1.7 Adjusting the monitoring settings ........................ 3-12
3.1.8 Controlling the remote server power ................... 3-13
3.1.9 Viewing PET information ....................................... 3-14
i vi vi vi vi v
Contents
3.2 ASUS Host Management Controller Setup .......................... 3-15
3.2.1 Installing and launching the ASUS HostManagement Controller Setup utility .................... 3-15
3.2.2 Command fields .................................................... 3-16
3.2.3 Initial ..................................................................... 3-16
3.2.4 View ...................................................................... 3-16
3.2.5 Set ........................................................................ 3-19
3.2.6 Monitor ................................................................. 3-20
3.2.7 Help ...................................................................... 3-20
Appendix:Appendix:Appendix:Appendix:Appendix: Reference informationReference informationReference informationReference informationReference information
A.1 LAN port for server management ........................................ A-2
A.2 BMC socket ........................................................................... A-4
A.3 Troubleshooting ................................................................... A-7
vvvvv
Notices
Federal Communications Commission StatementFederal Communications Commission StatementFederal Communications Commission StatementFederal Communications Commission StatementFederal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject tothe following two conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received including interferencethat may cause undesired operation.
This equipment has been tested and found to comply with the limits for aClass B digital device, pursuant to Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses and can radiate radiofrequency energy and, if not installed and used in accordance withmanufacturer’s instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will notoccur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined byturning the equipment off and on, the user is encouraged to try to correctthe interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that towhich the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Canadian Department of Communications StatementCanadian Department of Communications StatementCanadian Department of Communications StatementCanadian Department of Communications StatementCanadian Department of Communications Statement
This digital apparatus does not exceed the Class B limits for radio noiseemissions from digital apparatus set out in the Radio InterferenceRegulations of the Canadian Department of Communications.
This class B digital apparatus complies with CanadianThis class B digital apparatus complies with CanadianThis class B digital apparatus complies with CanadianThis class B digital apparatus complies with CanadianThis class B digital apparatus complies with CanadianICES-003.ICES-003.ICES-003.ICES-003.ICES-003.
The use of shielded cables for connection of the monitor to the graphicscard is required to assure compliance with FCC regulations. Changes ormodifications to this unit not expressly approved by the partyresponsible for compliance could void the user’s authority to operatethis equipment.
v iv iv iv iv i
Safety information
Electrical safetyElectrical safetyElectrical safetyElectrical safetyElectrical safety
• To prevent electrical shock hazard, disconnect the power cable fromthe electrical outlet before relocating the server.
• When adding or removing devices to or from the server, ensure thatthe power cables for the devices are unplugged before the signal cablesare connected. If possible, disconnect all power cables from the existingserver before you add a device.
• Before connecting or removing signal cables from the server, ensurethat all power cables are unplugged.
• Seek professional assistance before using an adapter or extension cord.These devices could interrupt the grounding circuit.
• Make sure that your power supply is set to the correct voltage in yourarea. If you are not sure about the voltage of the electrical outlet youare using, contact your local power company.
• If the power supply is broken, do not try to fix it by yourself. Contact aqualified service technician or your retailer.
Operation safetyOperation safetyOperation safetyOperation safetyOperation safety
• Before installing any component to the server, carefully read all themanuals that came with the package.
• Before using the product, make sure all cables are correctly connectedand the power cables are not damaged. If you detect any damage,contact your dealer immediately.
• To avoid short circuits, keep paper clips, screws, and staples away fromconnectors, slots, sockets and circuitry.
• Avoid dust, humidity, and temperature extremes. Do not place theproduct in any area where it may become wet.
• Place the product on a stable surface.
• If you encounter technical problems with the product, contact a qualifiedservice technician or your retailer.
v i iv i iv i iv i iv i i
About this guide
This user guide contains the information you need when installing andconfiguring the server management card.
How this guide is organizedHow this guide is organizedHow this guide is organizedHow this guide is organizedHow this guide is organized
This manual contains the following parts:
••••• Chapter 1: Product introduct ionChapter 1: Product introduct ionChapter 1: Product introduct ionChapter 1: Product introduct ionChapter 1: Product introduct ion
This chapter describes the server management board features and thenew technologies it supports.
••••• Chapter 2: Insta l lat ionChapter 2: Insta l lat ionChapter 2: Insta l lat ionChapter 2: Insta l lat ionChapter 2: Insta l lat ion
This chapter provides instructions on how to install the board to theserver system and install the utilities that the board supports.
••••• Chapter 3: Software supportChapter 3: Software supportChapter 3: Software supportChapter 3: Software supportChapter 3: Software support
This chapter tells you how to use the software applications that theserver management board supports.
••••• Appendix: Troubleshoot ingAppendix: Troubleshoot ingAppendix: Troubleshoot ingAppendix: Troubleshoot ingAppendix: Troubleshoot ing
The Appendix lists the common problems that you may encounterwhen installing or usingthe server management board or any of thebundled utilities.
Where to find more informationWhere to find more informationWhere to find more informationWhere to find more informationWhere to find more information
Refer to the following sources for additional information and for productand software updates.
1 .1 .1 .1 .1 . ASUS webs itesASUS webs itesASUS webs itesASUS webs itesASUS webs ites
The ASUS website provides updated information on ASUS hardwareand software products. Refer to the ASUS contact information.
2 .2 .2 .2 .2 . Opt ional documentat ionOpt ional documentat ionOpt ional documentat ionOpt ional documentat ionOpt ional documentat ion
Your product package may include optional documentation, such aswarranty flyers, that may have been added by your dealer. Thesedocuments are not part of the standard package.
v i i iv i i iv i i iv i i iv i i i
Typography
Bo l d t e x tBo l d t e x tBo l d t e x tBo l d t e x tBo l d t e x t Indicates a menu or an item to select.
Italics Used to emphasize a word or a phrase.
<Key> Keys enclosed in the less-than and greater-than sign meansthat you must press the enclosed key.
Example: <Enter> means that you must press the Enter orReturn key.
<Key1+Key2+Key3> If you must press two or more keys simultaneously, the
key names are linked with a plus sign (+).
Example: <Ctrl+Alt+D>
Command Means that you must type the command exactly as shown,then supply the required item or value enclosed inbrackets.
Example: At the DOS prompt, type the command line:afudos /i[filename]afudos /iP5GD2.ROM
DANGER/WARNING: DANGER/WARNING: DANGER/WARNING: DANGER/WARNING: DANGER/WARNING: Information to prevent injury to yourselfwhen trying to complete a task.
CAUTION:CAUTION:CAUTION:CAUTION:CAUTION: Information to prevent damage to the componentswhen trying to complete a task.
NOTE: NOTE: NOTE: NOTE: NOTE: Tips and additional information to help you complete atask.
IMPORTANT: IMPORTANT: IMPORTANT: IMPORTANT: IMPORTANT: Instructions that you MUST follow to complete atask.
Conventions used in this guideConventions used in this guideConventions used in this guideConventions used in this guideConventions used in this guide
To make sure that you perform certain tasks properly, take note of thefollowing symbols used throughout this manual.
i xi xi xi xi x
ASMB-LE specifications summary
Specifications are subject to change without notice.
I P M II P M II P M II P M II P M I featu res featu res featu res featu res featu res
C P UC P UC P UC P UC P U
Ch ipsetCh ipsetCh ipsetCh ipsetCh ipset
Externa l BusExterna l BusExterna l BusExterna l BusExterna l BusAddress RangeAddress RangeAddress RangeAddress RangeAddress Range
Inte rna l RAMInterna l RAMInterna l RAMInterna l RAMInterna l RAM
Externa l RAMExterna l RAMExterna l RAMExterna l RAMExterna l RAM
F lash ROMF lash ROMF lash ROMF lash ROMF lash ROM
Inte r ruptIn te r ruptIn te r ruptIn te r ruptIn te r rupt
T imersT imersT imersT imersT imers
Sys temSystemSystemSystemSystemInte r faceIn te r faceIn te r faceIn te r faceIn te r face
Ser ia l /ModemSer ia l /ModemSer ia l /ModemSer ia l /ModemSer ia l /ModemInte r faceIn te r faceIn te r faceIn te r faceIn te r face
LAN Inte r faceLAN Inte r faceLAN Inte r faceLAN Inte r faceLAN Inte r face
B u sB u sB u sB u sB u s
Featu resFeatu resFeatu resFeatu resFeatu res
Sof twareSof twareSof twareSof twareSof twaresuppor tsuppor tsuppor tsuppor tsuppor t
IPMI 1.5-compliant and supports:- Auto monitoring sensor and event logging- IPMI Host I/O interface- Receiving and logging of event messages- IPMB/I2C system interface- System Watchdog Timer (ASR)
8-bit (80C32) 40 MHz
Winbond 83910
64 Kbyte (4-bank)
256 bytes
32 Kbytes
128 Kbytes
I2C, Timer, UART, RTC, LPC
16-bit system timerWatchdog timerReal Time Clock (RTC)
Low Pin CountSupports Keyboard Controller Style (KCS), ServerManagement Interface Chip (SMIC), and Block Transfer(BT) interfaces
Basic Mode and Terminal Mode
IPMI 1.5 Shared LAN
Four I2C busOne IPMB busTwo UART bus
Remote power on/offRemote rebootUpgradeable firmwareSNMP TrapDOS-based utility
ASUS Remote Console (ARC)ASUS Host Management Controller Utility (DOS-based)
xxxxx
1Productintroduction
This chapter describes the servermanagement board features and the newtechnologies it supports.
1 - 21 - 21 - 21 - 21 - 2 Chapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ion
1.1 Welcome!
Thank you for buying an ASUSThank you for buying an ASUSThank you for buying an ASUSThank you for buying an ASUSThank you for buying an ASUS®®®®® ASMB-LE server management ASMB-LE server management ASMB-LE server management ASMB-LE server management ASMB-LE server managementboard !board !board !board !board !
The ASUS ASMB-LE is an Intelligent Platform Management Interface (IPMI)1.5-compliant board that allows you to monitor, control, and manage aremote server from the local or central server in your local area network(LAN).
With the proprietary ASUS Remote Console interface, ASMB-LE offersround-the-clock remote server monitoring through component sensorsincluding CPU(s) temperature(s), system temperature, fan rotations, andpower supply voltages. The ASMB-LE also records each remote serversystem event for accurate and efficient troubleshooting.
The ASMB-LE comes with a power management feature that allows you topower on/off or reset the remote server giving you full control of power incritical situations. The server management board also comes with a FieldReplaceable Unit (FRU) information feature that gathers information onreplaceable system components or modules such as the motherboard orbackplane model name, serial number, manufacturer, etc. You can use theFRU information when reporting and/or replacing server systemcomponents.
Before you start installing the server management board check the items inyour package with the list below.
If any of the above items is damaged or missing, contact your retailer.
1.2 Package contents
Check your server management board package for the following items.
� ASUS ASMB-LE board
� Support CD
� User guide
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 1 - 31 - 31 - 31 - 31 - 3
1.3 Board layout
The ASUS ASMB-LE comes in a BMC package. The illustration below showsthe major components of the server management board.
LED indicatorsLED indicatorsLED indicatorsLED indicatorsLED indicators
The ASMB-LE board comes with two LED indicators: BMC heartbeat LEDand Power LED. Refer to the table below for the LED indications.
1.4 System requirements
Before you install the ASMB-LE board, check if your server system meetsthe following requirements:
• ASUS server motherboard with Baseboard Management Controller(BMC) socket*
• LAN (RJ-45) port for server management**
• Microsoft® Internet Explorer 5.5 or later
* Visit the ASUS website (www.asus.com) for an updated list of servermotherboards that support the ASMB-LE board.
** Refer to the Appendix section for details.
L E DL E DL E DL E DL E D N a m eN a m eN a m eN a m eN a m e S t a t u sS t a t u sS t a t u sS t a t u sS t a t u s Desc r i p t i onDesc r i p t i onDesc r i p t i onDesc r i p t i onDesc r i p t i on
L ED1LED1LED1LED1LED1 B M CB M CB M CB M CB M C Blinking ASMB-LE firmware is in execution.Hear tbeatHear tbeatHear tbeatHear tbeatHear tbeat Off The ASMB-LE firmware is corrupted or the
server system standby-power is off.
L ED2LED2LED2LED2LED2 Powe rPowe rPowe rPowe rPowe r On The managed server system is on.Off The managed server system is off.
S e r v e rS e r v e rS e r v e rS e r v e rS e r v e rmanagementmanagementmanagementmanagementmanagementc h i pc h i pc h i pc h i pc h i p
Boa rd connec to r sBoa rd connec to r sBoa rd connec to r sBoa rd connec to r sBoa rd connec to r s
F i rmwa re ch i pF i rmwa re ch i pF i rmwa re ch i pF i rmwa re ch i pF i rmwa re ch i p
Powe r LEDPowe r LEDPowe r LEDPowe r LEDPowe r LED
BMC hea r tbea t LEDBMC hea r tbea t LEDBMC hea r tbea t LEDBMC hea r tbea t LEDBMC hea r tbea t LED
* Connects to anIPMB connector onthe motherboard,when available.
1 - 41 - 41 - 41 - 41 - 4 Chapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ion
1.5 Network setup
The ASMB-LE server management board installed on the remote hostconnects to a local/central server via direct LAN connection or through anetwork hub. Below are the supported server management configurations.
Remote hos tRemote hos tRemote hos tRemote hos tRemote hos tw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LE
Loca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hASUS RemoteASUS RemoteASUS RemoteASUS RemoteASUS RemoteCont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)
Hub o r r ou te rHub o r r ou te rHub o r r ou te rHub o r r ou te rHub o r r ou te r
Direct LAN connectionDirect LAN connectionDirect LAN connectionDirect LAN connectionDirect LAN connection
LAN connection through a network hubLAN connection through a network hubLAN connection through a network hubLAN connection through a network hubLAN connection through a network hub
Remote hos tRemote hos tRemote hos tRemote hos tRemote hos tw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LE
RJ -45 cab l eR J -45 cab l eR J -45 cab l eR J -45 cab l eR J -45 cab l e
Loca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hASUS RemoteASUS RemoteASUS RemoteASUS RemoteASUS RemoteCont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)
2Installation
This chapter provides instructions onhow to install the board to the serversystem and install the utilities that theboard supports.
2 - 22 - 22 - 22 - 22 - 2 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion
2.2 Hardware installation
To install the server management board:
1. Remove the server systemcover, then locate theBaseboard ManagementController (BMC) socket on themotherboard.
2.1 Before you proceed
Take note of the following precautions before you install the servermanagement board to the server system.
• Unplug the server system power cord from the wall socket beforetouching any component.
• Use a grounded wrist strap or touch a safely grounded object or toa metal object, such as the power supply case, before handlingcomponents to avoid damaging them due to static electricity.
• Hold components by the edges to avoid touching the ICs on them.
• Whenever you uninstall any component, place it on a groundedantistatic pad or in the bag that came with the component.
• Before you insta l l o r remove any component , ensureBefore you insta l l o r remove any component , ensureBefore you insta l l o r remove any component , ensureBefore you insta l l o r remove any component , ensureBefore you insta l l o r remove any component , ensurethat the power supp ly i s sw itched off or the powerthat the power supp ly i s sw itched off or the powerthat the power supp ly i s sw itched off or the powerthat the power supp ly i s sw itched off or the powerthat the power supp ly i s sw itched off or the powercord i s detached f rom the power supp ly . cord i s detached f rom the power supp ly . cord i s detached f rom the power supp ly . cord i s detached f rom the power supp ly . cord i s detached f rom the power supp ly . Failure to do somay cause severe damage to the motherboard, peripherals, and/orcomponents.
2. Position the board at a 30º-45ºangle, then match the notch onthe board with the break on thesocket.
Refer to the Appendixsection for the location ofthe BMC socket on supportedmotherboards.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 2 - 32 - 32 - 32 - 32 - 3
3. Carefully push the board to thesocket until its connectors(golden fingers) arefully-inserted to the socket.
4. Press the board firmly until theBMC socket retaining clips snapback and secure the board inplace.
When installed, the boardappears as shown.
5. Re-install the server system cover, then connect the power plug to agrounded wall socket.
6. Insert the LAN cable plug to the LAN port for server management.
Refer to the Appendix for the location of the LAN port for servermanagement on various server motherboards.
7. For direct LAN configuration, connect the other end of the LAN cableto the local/central server LAN port.
For connection to a network hub or router, connect the other end ofthe LAN cable to the network hub or router.
2 - 42 - 42 - 42 - 42 - 4 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion
To uninstall the board:
1. Simultaneously press the BMCsocket retaining clips outwarduntil the board tilts up.
2. Carefully pull the board outfrom the BMC socket, then setaside.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 2 - 52 - 52 - 52 - 52 - 5
2.3 Network configuration
You must configure the network settings of both the remote server andthe local/central server to establish communication and monitor or controlthe remote server. Prepare the support CD and a bootable floppy disk toconfigure the network settings.
2.3.12.3.12.3.12.3.12.3.1 Running the ASMC utilityRunning the ASMC utilityRunning the ASMC utilityRunning the ASMC utilityRunning the ASMC utility
The ASUS Server Management Card Utility allows you to know the MACaddress of the server motherboard and to set the IP address. This utility isavailable from the support CD that came with the package.
To run the ASMC utility:
1. Restart the remote server, then place the support CD to theoptical drive.
2. Press <1> (FreeDOS command prompt) when the screen prompts youto select from available boot options.
3. When the A:> prompt appears, type X: (where X is the drive letter ofthe optical drive).
4. When the X:> prompt appears, type cd\asms\asmc\le\dostool,then press <Enter>.
5. At the prompt, type asmc ?, then press <Enter> to display the ASMCUtility Help Menu. The screen appears as shown.
+-----------------------------------------------------+| ASUS Server Management Card Utility 1.00 Help Menu |+-----------------------------------------------------+Usage:ASMC -flash -save filenameASMC -flash -load filenameASMC -i2c_read bus_num dev_num offsetASMC -i2c_write bus_num dev_num offset data
ASMC -sdr -save filenameASMC -sdr -load filenameASMC -kcs[smic/bt/pci_smic] NetFn command data....ASMC -tco enable[disable]ASMC -bmc_ip ip_addr[10.10.10.20]ASMC -bmc_macASMC -pet_ip_mac ip_addr[10.10.10.20] mac_addr[010203040506]ASMC -bmc_info
Refer to the table on the next page for a description of the help menuoptions.
2 - 62 - 62 - 62 - 62 - 6 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion
2.3.22.3.22.3.22.3.22.3.2 Configuring the LAN controllerConfiguring the LAN controllerConfiguring the LAN controllerConfiguring the LAN controllerConfiguring the LAN controller
Before you can establish connection to the ASMB-LE board, you mustconfigure the LAN port for server management being used by the remoteserver to connect to the local/central server.
To configure the LAN port of the remote server:
1. On the prompt, type asmc -tco enableasmc -tco enableasmc -tco enableasmc -tco enableasmc -tco enable, then press <Enter>. Thescreen displays the auto-detected information including themotherboard name, vendor-device code, and the physical address(MAC) of the remote server.
A:\>asmc -tco enableDetect MotherBoard -> (PSCH-LR)Detect KCS Interface
Bus Dev Fun Vendor-Device MAC======== ====== ======= ====== ============== ===================PSCH-LR 01 01 00 8086 - 1075 00-11-2F-0F-A2-21
Please shutdown the system (Standby power) to enable TCO mode!
A:\>
ASMC Help Menu optionsASMC Help Menu optionsASMC Help Menu optionsASMC Help Menu optionsASMC Help Menu options
Opt i o n sOp t i o n sOp t i o n sOp t i o n sOp t i o n s Desc r i p t i onDesc r i p t i onDesc r i p t i onDesc r i p t i onDesc r i p t i on
-flash -save filename Save the current firmware to a file
-flash -load filename Update the ASMB-LE firmware
-i2c_read bus_num dev_num offset Send the read I2C command
-i2c_write bus_num dev_num offset data Send the written I2C command
-sdr -save filename Save the SDR data to file
-sdr -load filename Update the SDR data from file
-kcs[smic/bt/pci_smic] NetFn command data.... Send IPMI command
-tco enable[disable] Enable or disable TCO mode
-bmc_ip ip_addr[10.10.10.20] Write the BMC IP address
-bmc_mac Auto-write the BMC MAC addresses
-pet_ip_mac ip_addr[10.10.10.20] mac_addr[010203040506] Write the PET destination IP and MAC addresses
-bmc_info Displays the BMC and PET IP and MACaddresses
2. Shutdown the remote server, then disconnect the power plug from theelectrical socket to enable the TCO mode.
3. Restart the remote server from the support CD.
The TCO (Total Cost Ownership) interface for Intel® Fast Ethernet andGigabit LAN controllers allows you to manage the remote server systemeven when its operating system is not fully functional.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 2 - 72 - 72 - 72 - 72 - 7
A:\>asmc -bmc_ip 169.254.137.105Detect MotherBoard -> (PSCH-LR)Detect KCS InterfaceNew BMC IP : 169.254.137.105
A:\>
4. Run the ASMC utility from the support CD following the instructions inthe previous section.
5. Type asmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxx, then press <Enter> toassign any IP address to the remote server LAN port. The screendisplays the request and response buffer. Write the remote server IPaddress in a piece of paper for reference.
A:\>asmc -bmc_macDetect MotherBoard -> (PSCH-LR)Detect KCS Interface
Bus Dev Fun Vendor-Device MAC======== ====== ======= ====== ============== ===================PSCH-LR 01 01 00 8086 - 1075 00-11-2F-0F-A2-21New BMC MAC: 00 11 2F 0F A2 21
A:\>
6. Type asmc -bmc_mac asmc -bmc_mac asmc -bmc_mac asmc -bmc_mac asmc -bmc_mac on the prompt, then press <Enter>. Thescreen displays the physical address (MAC) of the remote server.Write the MAC address in a piece of paper for reference.
When finished, the utility returns to the DOS prompt.
Make sure that the assigned IP address for both remote and local/centralservers are in the same subnet. You can use the network settings utilityin your OS to check.
7. Type asmc -bmc_info asmc -bmc_info asmc -bmc_info asmc -bmc_info asmc -bmc_info on the prompt, then press <Enter> todisplay the IP and MAC addresses of the BMC and PET.
8. Restart the remote server, enter the BIOS setup, then boot from thehard disk drive.
9. Adjust the local/central server network settings, if necessary.
A:\>asmc -bmc_macDetect MotherBoard -> (PSCH-LR)Detect KCS InterfaceBMC IP : 169.254.137.105BMC MAC: 00 11 2F 0F A2 21PET IP : 169.254.137.106PET MAC: 00 E0 18 9B BB 44
A:\>
2 - 82 - 82 - 82 - 82 - 8 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion
2.3.32.3.32.3.32.3.32.3.3 Updating the ASMC-LE firmwareUpdating the ASMC-LE firmwareUpdating the ASMC-LE firmwareUpdating the ASMC-LE firmwareUpdating the ASMC-LE firmware
You can use the ASUS System Web-based Management (ASWM) applicationto update the ASMC-LE firmware. To do this:
1. Download the latest ASMB-LE firmware from the ASUS website(www.asus.com), then save the firmware file to the server.
2. Launch the ASWM application. If ASWM is not yet installed on yourserver system, use the support CD to install the application.
3. Click the Conf igurat ion Conf igurat ion Conf igurat ion Conf igurat ion Conf igurat ion link, then select IPMI F lash IPMI F lash IPMI F lash IPMI F lash IPMI F lash from the menu.
4. Click Browse Browse Browse Browse Browse to locate the latest firmware you downloaded earlier.When selected, the firmware path and filename appears in theF i rmware Image Name F i rmware Image Name F i rmware Image Name F i rmware Image Name F i rmware Image Name field.
5. Click App ly App ly App ly App ly App ly to update the ASMC-LE firmware.
33333
44444
55555
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 2 - 92 - 92 - 92 - 92 - 9
2.4 Software installation
You can monitor, control, or manage the remote server from thelocal/central server using the ASUS Remote Console (ARC). The ARC is aweb-based application available from the support CD that came with theASMB-LE package. You must install the ARC on the local/central server toaccess the remote server.
2.4.12.4.12.4.12.4.12.4.1 Installing the ARCInstalling the ARCInstalling the ARCInstalling the ARCInstalling the ARC
To install the ARC to the local/central server:
1. Place the support CD to the optical drive. The CD automaticallydisplays the Dr iversDr iversDr iversDr iversDr ivers menu if Autorun is enabled in your computer.
If Autorun is NOT enabled in your computer, browse the contents of thesupport CD to locate the file ASSETUP.EXE from the BIN folder.Double-click the ASSETUP.EXE to run the CD.
2. Click the Management SoftwareManagement SoftwareManagement SoftwareManagement SoftwareManagement Software tab, then click the item Insta l l Insta l l Insta l l Insta l l Insta l lASUS IPMI Remote Console ut i l i tyASUS IPMI Remote Console ut i l i tyASUS IPMI Remote Console ut i l i tyASUS IPMI Remote Console ut i l i tyASUS IPMI Remote Console ut i l i ty.
2 -102 -102 -102 -102 -10 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion
3. Follow the installation wizard instructions to install the utility.
2.4.22.4.22.4.22.4.22.4.2 Launching ARCLaunching ARCLaunching ARCLaunching ARCLaunching ARC
To launch the ARC utility:
Click Start Start Start Start Start > Al l Programs Al l Programs Al l Programs Al l Programs Al l Programs > ASUS Remote Console ASUS Remote Console ASUS Remote Console ASUS Remote Console ASUS Remote Console > ASUSASUSASUSASUSASUSRemote ConsoleRemote ConsoleRemote ConsoleRemote ConsoleRemote Console from the Windows® desktop.
or
Double-click the ASUS RemoteConsole icon on the Windows®
desktop.
3Softwaresupport
This chapter tells you how to use thesoftware applications that the servermanagement board supports.
3 - 23 - 23 - 23 - 23 - 2 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
3.1 ASUS Remote Console (ARC)
The ASUS Remote Console (ARC) is a web-based utility that allows you tomonitor the remote host’s hardware information including temperatures,fan rotations, voltages, and power. This application also lets you instantlypower on/off or reset the remote server.
The ARC window is made up of six sections: Menu Menu Menu Menu Menu bar, Tool Tool Tool Tool Tool bar,Navigation Navigation Navigation Navigation Navigation window, Detai l/SEL Detai l/SEL Detai l/SEL Detai l/SEL Detai l/SEL window, Event Event Event Event Event window, and Status Status Status Status Status bar.
3.1.13.1.13.1.13.1.13.1.1 ARC sectionsARC sectionsARC sectionsARC sectionsARC sections
Menu barMenu barMenu barMenu barMenu bar
The Menu bar contains all the commands for the ARC application. Click on amenu to display a list of available commands.
Menu ba rMenu ba rMenu ba rMenu ba rMenu ba rToo l b a rToo l b a rToo l b a rToo l b a rToo l b a r
Nav i ga t i onNav i ga t i onNav i ga t i onNav i ga t i onNav i ga t i onw i n d o ww i n d o ww i n d o ww i n d o ww i n d o w
Deta i l /SEL w i ndowDeta i l /SEL w i ndowDeta i l /SEL w i ndowDeta i l /SEL w i ndowDeta i l /SEL w i ndow
Even t w i ndowEven t w i ndowEven t w i ndowEven t w i ndowEven t w i ndow
Sta tu s ba rS t a tu s ba rS t a tu s ba rS t a tu s ba rS t a tu s ba r
M e n uM e n uM e n uM e n uM e n u Ava i l ab l e commandsAva i l ab l e commandsAva i l ab l e commandsAva i l ab l e commandsAva i l ab l e commands
S e r v e rS e r v e rS e r v e rS e r v e rS e r v e r add, delete, connect, disconnect server or change the server settings
V i e wV i e wV i e wV i e wV i e w show or hide the tool bar, status bar, navigation, and PET windows
Con t r o lCon t r o lCon t r o lCon t r o lCon t r o l turn on/off or reset the remote server
E d i tE d i tE d i tE d i tE d i t delete the System Event Log (SEL) or PET log
H e l pH e l pH e l pH e l pH e l p view information about the ARC application
Tool barTool barTool barTool barTool bar
The Tool bar contains buttons corresponding to the most commonly usedcommands. The Tool bar offers faster access and execution of thesecommands. Move the mouse pointer over a button to display its function.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 - 33 - 33 - 33 - 33 - 3
Navigation windowNavigation windowNavigation windowNavigation windowNavigation window
The Navigation window displays the directory ofconnected and disconnected remote server(s).For multiple monitoring, this window allows you tonavigate through the remote servers. Click theAl l Servers Al l Servers Al l Servers Al l Servers Al l Servers root directory to display allconnected and disconnected servers, then clickon the server you want to monitor or control.
Click before the server connection to display available remote serverinformation including the Sensor Data Record (SDR), Field Replaceable Unit(FRU), and System Event Log (SEL).
Some remote server information (such as the SDR) contains several sensorgroups such as TemperatureTemperatureTemperatureTemperatureTemperature, Vo l tageVo ltageVo ltageVo ltageVo ltage, F a nF anFanFanFan, and Chass is Intrus ionChass is Intrus ionChass is Intrus ionChass is Intrus ionChass is Intrus ion.Click before the remote server information to display the sensor groups.
Click before a sensor group to display individual sensors. For example,clicking before the sensor group Temperature Temperature Temperature Temperature Temperature displays the CPU1 andsystem temperatures.
You can also change the server directorydisplay by clicking the buttons on top of thewindow. For example, clicking the I P I P I P I P I P buttondisplays the remote server IP address insteadof the remote server name (NNNNN). Selecting I DI DI DI DI Ddisplays the remote server ID instead of theserver name or IP address.
Senso r g roupsSenso r g roupsSenso r g roupsSenso r g roupsSenso r g roups SensorsSensorsSensorsSensorsSensors
3 - 43 - 43 - 43 - 43 - 4 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
Event windowEvent windowEvent windowEvent windowEvent window
The Event window displays the Platform Event Trap (PET) received by theARC. The PET information includes the event index, source IP address,enterprise, community, generic and specific traps, and time ticks. The PETinformation is a system management alert in SNMP Trap format and is usedis used for IPMI alerting as well as alerts using the ASF specification.
Status barStatus barStatus barStatus barStatus bar
The Status bar located at the bottom of the ARC window displays theconnection status to the remote server, connection duration, IP address ofthe remote server, and the progress of SDR/SEL/FRU informationdownload.
Detail/SEL windowDetail/SEL windowDetail/SEL windowDetail/SEL windowDetail/SEL window
The Detail/SEL window displays the detailed SDR and FRU information, andthe System Event Log (SEL). The window provides the link for detailedsensor information or system events and allows you to adjust the sensorthreshold values.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 - 53 - 53 - 53 - 53 - 5
3.1.23.1.23.1.23.1.23.1.2 Connecting to the remote serverConnecting to the remote serverConnecting to the remote serverConnecting to the remote serverConnecting to the remote server
To connect to the remote server:
1. From the menu bar, clickServerServerServerServerServer, then select NewNewNewNewNew. AnAdd new serverAdd new serverAdd new serverAdd new serverAdd new serverconnect ion connect ion connect ion connect ion connect ion window appears.
2. Type the remote server nameand IP address on the fields.Click Save Defau ltSave Defau ltSave Defau ltSave Defau ltSave Defau lt to set theremote server connection asthe default. Otherwise, clickO KO KO KO KO K to continue or Cance l Cance l Cance l Cance l Cance l toclose the window.
The default server connection name and IP address are automaticallydisplayed everytime you add a new server connection.
3. When prompted, select I PM II PM II PM II PM II PM IServerServerServerServerServer, then click Cont inueCont inueCont inueCont inueCont inue.
3 - 63 - 63 - 63 - 63 - 6 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
The navigation window displays the remote server. The available remoteserver information are displayed on the Detail/SEL window.
4. Click before the remote server to display the remote serverinformation, then select from the list. You can also double-click aremote server information from the Detail/SEL window.
5. When prompted, enter thedefault user name (adm) andpassword (asusadm).
6. Set the connection requestlevel authentication andprivilege, then click O KO KO KO KO K.
The default connection request level authentication is MD2 MD2 MD2 MD2 MD2 (MessageDigest Algorithm 2) with Admin i s t rator Admin i s t rator Admin i s t rator Admin i s t rator Admin i s t rator privileges. You may changethese configuration according to your network settings or preference.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 - 73 - 73 - 73 - 73 - 7
3.1.33.1.33.1.33.1.33.1.3 Retrieving sensor informationRetrieving sensor informationRetrieving sensor informationRetrieving sensor informationRetrieving sensor information
The Sensor Data Record (SDR) provides remote server system informationthrough available sensors including CPU/system/power temperatures,voltages, fan speeds, chassis intrusion, etc. The SDR also providesinformation on the sensor location (e.g. CPU1, CPU2, FAN1), eventgeneration, and access information.
To retrieve a sensor information:
1. From the navigation window, click before the server name todisplay the remote server information.
2. Click before the SDR SDR SDR SDR SDR to display the sensor groups (e.g.Temperature), then click before a sensor group to display theindividual sensors. Select a sensor (e.g. CPU1 THERMAL) to display itsvalues in the Detail/SEL window.
The Detail/SEL window displays the sensor data attributes, values,and meanings. From this window, you can adjust the sensor thresholdvalues by clicking the up/down arrow button after each value.
3 - 83 - 83 - 83 - 83 - 8 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
3. Click Mo reMoreMoreMoreMore. A sensor windowappears displaying additionalinformation on the sensor.
The Informat ion Informat ion Informat ion Informat ion Informat ion tab displaysbasic sensor informationincluding the sensor name,current status, current value,and sensor type.
The tab also displays thesensor record ID and SDRversion.
4. Click the Sett ings Sett ings Sett ings Sett ings Sett ings tab toadjust the sensor thresholdvalues. Click on the up/downarrow button after eachthreshold value to adjust.
Click O K O K O K O K O K to close the window.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 - 93 - 93 - 93 - 93 - 9
3.1.43.1.43.1.43.1.43.1.4 Displaying all remote server sensorsDisplaying all remote server sensorsDisplaying all remote server sensorsDisplaying all remote server sensorsDisplaying all remote server sensors
To display all remote server sensors in graphical format:
1. From the navigation window, click before the server name to openthe remote server information.
2. Click Al l Sensors va lueAl l Sensors va lueAl l Sensors va lueAl l Sensors va lueAl l Sensors va lue. All remote server sensors are displayed onthe Information window in graphical format.
The color bar represents the upper/lower threshold values of eachsensor. The green pointer indicates the current value of the sensor.
3 -103 -103 -103 -103 -10 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
3.1.53.1.53.1.53.1.53.1.5 Displaying FRU informationDisplaying FRU informationDisplaying FRU informationDisplaying FRU informationDisplaying FRU information
The Field Replaceable Unit (FRU) information provides the manufacturer,product name, and/or serial number of various modules and componentsinstalled on the remote server. For example, the FRU feature can displaythe remote server motherboard name, model, and serial number. You canuse this feature when retrieving information on a module or componentinstalled on the remote server.
The FRU information feature allows you to obtain component or moduleinformation even when the remote server is down or off.
To display the FRU information:
1. From the navigation window, click before the server name to openthe remote server information.
2. Click before the FRU FRU FRU FRU FRU to display available FRU information, then click before the module/component. Select a module or component from
the list to display the FRU information in the Detail/SEL window.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -113 -113 -113 -113 -11
3.1.63.1.63.1.63.1.63.1.6 Displaying system event logsDisplaying system event logsDisplaying system event logsDisplaying system event logsDisplaying system event logs
The System Event Log (SEL) is a non-volatile storage area where all remoteserver system events are stored for real-time tracking or later retrieval.The ARC application can display system events for efficient remote servermonitoring and troubleshooting.
To display the sytem events:
1. From the navigation window, click before the server connection,then click S ELSELSELSELSEL. The status bar displays the progress of the SELdownload. When finished, the Detail/SEL window displays the systemevents in chronological order.
2. Double-click an event todisplay an EventEventEventEventEventInformat ion Informat ion Informat ion Informat ion Informat ion window.
This window displays thesensor type and record ID,event message, current andthreshold values, and othersystem event information.
3. Click OK to close the window.
3 -123 -123 -123 -123 -12 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
3.1.73.1.73.1.73.1.73.1.7 Adjusting the monitoring settingsAdjusting the monitoring settingsAdjusting the monitoring settingsAdjusting the monitoring settingsAdjusting the monitoring settings
The ARC application allows you to adjust the remote server monitoringsettings including SEL polling, SDR reading, ASF, and PET.
To adjust the monitoring settings:
1. Click Server Server Server Server Server on the menu bar,then select Sett ing Sett ing Sett ing Sett ing Sett ing from thedrop-down menu. A ServerServerServerServerServerSett ing Sett ing Sett ing Sett ing Sett ing window appears.
2. Click on the up/down arrowbutton after each setting toadjust the value.
3. Click O K O K O K O K O K to save your changesand close the window.
Otherwise, click Cance lCance lCance lCance lCance l toignore your changes.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -133 -133 -133 -133 -13
3.1.83.1.83.1.83.1.83.1.8 Controlling the remote server powerControlling the remote server powerControlling the remote server powerControlling the remote server powerControlling the remote server power
The ASMB-LE board through the ARC application allows you to power up,power down, or reset the remote server using the power menu.
2. Click Yes Yes Yes Yes Yes when the Conf i rmConf i rmConf i rmConf i rmConf i rmpower down power down power down power down power down window appears.
3. The remote server is turned off.Click O K O K O K O K O K to close the window.
Use the same instructions asreference when powering up orresetting the remote server.
Before turning off or resetting the remote server, make sure that it isnot being used and that no application is currently running to avoid dataloss.
To power down the remote server:
1. Click Contro l Contro l Contro l Contro l Contro l on the menu bar,then select Power downPower downPower downPower downPower downfrom the drop-down menu.
O RO RO RO RO R
Click the power down button onthe tool bar.
3 -143 -143 -143 -143 -14 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
3.1.93.1.93.1.93.1.93.1.9 Viewing PET informationViewing PET informationViewing PET informationViewing PET informationViewing PET information
The Platform Event Trap or PET is an SNMP trap used for systemmanagement alerts. When the ARC receives a PET, it displays a pop-upwindow notifying you of the alert and its source (IP address). Right-clickthe window to close.
You need to install an SNMP service to the remote server to receivePET information.
Important not ice for WindowsImportant not ice for WindowsImportant not ice for WindowsImportant not ice for WindowsImportant not ice for Windows®®®®® XP (Serv ice Pack 2) users XP (Serv ice Pack 2) users XP (Serv ice Pack 2) users XP (Serv ice Pack 2) users XP (Serv ice Pack 2) users
If the remote server system is behind a firewall, you must create a UDPport to receive PET information.
To create a UDP port:
1. Double-click the My ComputerMy ComputerMy ComputerMy ComputerMy Computer icon from the Windows® desktop,then click the My Network P lacesMy Network P lacesMy Network P lacesMy Network P lacesMy Network P laces link.
2. Click the View network connect ionsView network connect ionsView network connect ionsView network connect ionsView network connect ions link, then select the LANconnection the remote server system is using.
3. Right-click the LAN connection, then select Propert ies Propert ies Propert ies Propert ies Propert ies from thedrop-down menu.
4. Click the Advanced Advanced Advanced Advanced Advanced tab, then click the Sett ings Sett ings Sett ings Sett ings Sett ings button.
5. On the Serv ices Serv ices Serv ices Serv ices Serv ices tab, click the Add Add Add Add Add button to display a Serv iceServ iceServ iceServ iceServ iceSett ings Sett ings Sett ings Sett ings Sett ings window.
6. Type a name on the Descr ipt ion of service f ie ldDescr ipt ion of service f ie ldDescr ipt ion of service f ie ldDescr ipt ion of service f ie ldDescr ipt ion of service f ie ld (i.e. ASUS ARC).
7. Type the IP address of the local/central server, then set the Externa lExterna lExterna lExterna lExterna land Interna l Port number Interna l Port number Interna l Port number Interna l Port number Interna l Port number to 162162162162162.
8. Select U D PU D PU D PU D PU D P, then click O KO KO KO KO K. The created service is displayed in theServices list. Check the box before the service, then click O KO KO KO KO K.
You must also adjust the Internet Explorer settings to allow active contentsto run in the local/central server. To do this:
1. From the Internet Explorer Internet Explorer Internet Explorer Internet Explorer Internet Explorer menu, click Too l sToo l sToo l sToo l sToo l s, then selectInternet Opt ionsInternet Opt ionsInternet Opt ionsInternet Opt ionsInternet Opt ions from the drop-down menu.
2. Click the Advanced Advanced Advanced Advanced Advanced tab.
3. Enable the item “Allow active content to run in files on My ComputerAllow active content to run in files on My ComputerAllow active content to run in files on My ComputerAllow active content to run in files on My ComputerAllow active content to run in files on My Computer”.
4. Click the App ly App ly App ly App ly App ly button, then click OK OK OK OK OK to close the window.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -153 -153 -153 -153 -15
3.2 ASUS Host Management Controller Setup
The ASUS Host Management Controller Setup utility provides preciseconfiguration and basic functions including System Event Log (SEL)generation and System Data Record (SDR) reading in DOS mode.
This utility also supplies configuration sequences for the type of hostinterface as well as direct real-time monitoring of system informationincluding CPU temperature(s), fan speeds and system voltages.
3.2.13.2.13.2.13.2.13.2.1 Installing and launching the ASUS HostInstalling and launching the ASUS HostInstalling and launching the ASUS HostInstalling and launching the ASUS HostInstalling and launching the ASUS HostManagement Controller Setup utilityManagement Controller Setup utilityManagement Controller Setup utilityManagement Controller Setup utilityManagement Controller Setup utility
To install the ASUS Host Management Controller Setup utility:
1. Boot the server in DOS mode using the support CD.
2. When the A:> prompt appears, type X: (where X is the drive letter ofthe optical drive).
3. When the X:> prompt appears, type cd\asms\asmc\le\dostool,then press <Enter>.
4. At the prompt, type asmc, then press <Enter> to display the ASMCUtility Help Menu. The screen appears as shown.
5. The main utility screen appears. Press <Enter>.
A:\>E:
E:\>cd\asms\asmc\le\dostool
E:\cd\asms\asmc\le\dostool>asmc
3 -163 -163 -163 -163 -16 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
3.2.23.2.23.2.23.2.23.2.2 Command fieldsCommand fieldsCommand fieldsCommand fieldsCommand fields
The utility menu bar has five commands: Initial, View, Set, Monitor andHelp. You can select a command using the left or right arrow button on thekeyboard. After selecting a command, use the down arrow key to displayavailable options. Select a command, then press <Enter> to execute.
3.2.43.2.43.2.43.2.43.2.4 ViewViewViewViewView
The V iew V iew V iew V iew V iew command displays the Baseboard Management Controller (BMC)data record including the System Event Log System Event Log System Event Log System Event Log System Event Log (SEL), the System DataSystem DataSystem DataSystem DataSystem DataRecord Record Record Record Record (SDR), and general BMC information.
3.2.33.2.33.2.33.2.33.2.3 InitialInitialInitialInitialInitial
The Initial command allows you to clear the SEL information or exit theutility.
Go to In i t ia l In i t ia l In i t ia l In i t ia l In i t ia l command, then select C lear SEL C lear SEL C lear SEL C lear SEL C lear SEL to empty all System EventLog information for a refresh set of data records. Use the C lear SELClear SELClear SELClear SELClear SELcommand when creating a new log that begins at an exact time for precisesystem monitoring.
Select Ex i t Ex i t Ex i t Ex i t Ex i t to close the utility and return to the DOS prompt.
Menu op t i onsMenu op t i onsMenu op t i onsMenu op t i onsMenu op t i onsMenu ba rMenu ba rMenu ba rMenu ba rMenu ba r
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -173 -173 -173 -173 -17
To view the System Data Record (SDR):To view the System Data Record (SDR):To view the System Data Record (SDR):To view the System Data Record (SDR):To view the System Data Record (SDR):
1. Select BMC SDRBMC SDRBMC SDRBMC SDRBMC SDR from the V iew V iew V iew V iew V iew command option, then press<Enter>. A complete list of data records appears on the left pane. Theright pane displays the sensor data information.
The number on the bottom left of the screen indicates the datarecord displayed in the right window pane over the total number ofsensor data records in the remote host.
2. Use the down arrow key to display the next sensor data record.
3. Press <Esc> to return to the main screen.
To view the System Event Log (SEL):To view the System Event Log (SEL):To view the System Event Log (SEL):To view the System Event Log (SEL):To view the System Event Log (SEL):
1. Select BMC SDRBMC SDRBMC SDRBMC SDRBMC SDR from the V iew V iew V iew V iew V iew command option, then press<Enter>. A complete list of system event records appear on the leftpane. The right pane displayes the SEL information.
The number on the left bottom of the window shows the systemevent displayed in the right window pane over the total number ofsystem events in the remote host.
2. Use the down arrow key to display the next sensor event.
3. Press <Esc> to return to the main screen.
3 -183 -183 -183 -183 -18 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
To view the BMC information:To view the BMC information:To view the BMC information:To view the BMC information:To view the BMC information:
1. Select BMC InfoBMC InfoBMC InfoBMC InfoBMC Info from the V iew V iew V iew V iew V iew command option, then press<Enter>. A list of BMC information appears on the left pane.
2. Use the down arrow button to select a BMC information. The BMCinformation is displayed in the right pane.
3. Press <Esc> to return to the main screen.
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -193 -193 -193 -193 -19
3.2.53.2.53.2.53.2.53.2.5 SetSetSetSetSet
The Set Set Set Set Set command controls the host interface type and the correct BMC time.
You can select from the following interfaces:
KCS InterfaceKCS InterfaceKCS InterfaceKCS InterfaceKCS Interface - Keyboard Controller Style
SMIC InterfaceSMIC InterfaceSMIC InterfaceSMIC InterfaceSMIC Interface - Server Management Interface Chip
BF InterfaceBF InterfaceBF InterfaceBF InterfaceBF Interface - Block Transfer
PCI InterfacePCI InterfacePCI InterfacePCI InterfacePCI Interface - Peripheral Component Interconnect
3. When finished, press <Esc> to return to the main screen.
To set the BMC Timer:To set the BMC Timer:To set the BMC Timer:To set the BMC Timer:To set the BMC Timer:
1. Select BMC T imerBMC T imerBMC T imerBMC T imerBMC T imer from the Set Set Se t Se t Se t command option, then press<Enter>.
2. Set the BMC IPMI timer to the current system time.
3. When finished, press <Esc> to return to the main screen.
To select the host interface:To select the host interface:To select the host interface:To select the host interface:To select the host interface:
1. Select Host InterfaceHost InterfaceHost InterfaceHost InterfaceHost Interface from the Set Se t Se t Se t Se t command option, then press<Enter>. The screen displays the host interfaces supported by theserver management board.
2. Use the down arrow button to select a host interface, then press <Enter>.
3 -203 -203 -203 -203 -20 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support
3.2.73.2.73.2.73.2.73.2.7 HelpHelpHelpHelpHelp
The He lp He lp He lp He lp He lp command displays the available utility options, utility version,and copyright information.
3.2.63.2.63.2.63.2.63.2.6 MonitorMonitorMonitorMonitorMonitor
The Mon itor Mon itor Mon itor Mon itor Mon itor command displays real-time data on the remote serversystem and CPU temperatures, voltages, and fan speeds.
To display a remote server information:To display a remote server information:To display a remote server information:To display a remote server information:To display a remote server information:
1. Select a sensor from the Mon itor Mon itor Mon itor Mon itor Mon itor command options, then press<Enter>. A list of server information appears on the left pane.
2. Use the down arrow button to select a monitor information. Theselected monitor information details are displayed in the right pane.
3. Press <Esc> to return to the main screen.
AReferenceinformation
The Appendix shows the location of theLAN port for server management onseveral motherboards and presentscommon problems that you mayencounter when installing or using theserver management board.
A - 2A - 2A - 2A - 2A - 2 Append ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ion
A.1 LAN port for server management
The ASUS server motherboards that support the ASMB-LE comes with twoLAN (RJ-45) ports: one for network connection and the other for servermanagement. You must identify and use the LAN port for servermanagement to connect the remote server to the local/central host (directLAN connection) or to the network hub or router.
Refer to the illustrations below to identify the LAN port for servermanagement on different server motherboards.
NCL-DS motherboardNCL-DS motherboardNCL-DS motherboardNCL-DS motherboardNCL-DS motherboard
PCH-DR motherboardPCH-DR motherboardPCH-DR motherboardPCH-DR motherboardPCH-DR motherboard
NCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboard
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) A - 3A - 3A - 3A - 3A - 3
NCLV-D motherboardNCLV-D motherboardNCLV-D motherboardNCLV-D motherboardNCLV-D motherboard
PSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboard
PSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboard
A - 4A - 4A - 4A - 4A - 4 Append ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ion
A.2 BMC socket
The ASUS server motherboards that support the ASMB-LE comes with aBaseboard Management Card (BMC) socket.
Refer to the illustrations below to locate the BMC socket on differentserver motherboards.
NCL-DS motherboardNCL-DS motherboardNCL-DS motherboardNCL-DS motherboardNCL-DS motherboard
PCH-DR motherboardPCH-DR motherboardPCH-DR motherboardPCH-DR motherboardPCH-DR motherboard
AMI8MbFWH
KBPWR1
J2
ATXPWR1
SATA1
CPU_FAN2
®
FM_CPU2
SEC_IDE
FLOPPY1
ATIRAGE XL
VGAController
SCSIA1
PCI6 (32-bit, 33MHz 5V) BUZZ1
3568
34 1
DDR DIMM_A1 (64/72 bit, 240-pin module)
COM2
SuperI/O
PCIX1 (64-bit, 133MHz 3V)
CR2032 3VLithium Cell
CMOS Power
PANEL1
FRNT_FAN1
mP
GA
604
NC
L-D
S
PS/2T: MouseB: Keyboard
USB1USB2
COM1
PAR
AL
LE
L P
OR
T
VGA1
RJ-45(LAN-1)
RJ-45(LAN-2)
DDR DIMM_B1 (64/72 bit, 240-pin module)
DDR DIMM_A2 (64/72 bit, 240-pin module)
DDR DIMM_B2 (64/72 bit, 240-pin module)
DDR DIMM_A3 (64/72 bit, 240-pin module)
DDR DIMM_B3 (64/72 bit, 240-pin module)
DDR DIMM_A4 (64/72 bit, 240-pin module)
DDR DIMM_B4 (64/72 bit, 240-pin module)
mP
GA
604
33cm (13in)
30.5
cm (
12in
)
PRI_IDE
SCSIB1
FRNT_FAN2
SATA2
ATX12V1
CPU_FAN1
FM_CPU1
PCIX2 (64-bit, 133MHz 3V)
PCIX4 (64-bit, 133MHz 3V)
PCIX5 (64-bit, 133MHz 3V)
IntelICH5R
AdaptecAIC-7902W
Intel E7520MCH
BMCCONN1
PSUSMB1
BPSMB1
IntelPXH
IntelPXH
AUX_PANEL1
HDLED1SCSI_EN1
USB34
US
BP
W34
CLRTC1
PCIE3VGA_EN1
RECPVERY1LAN1_EN1
LAN2_EN1
BroadcomBCM5721
BroadcomBCM5721
SB_PWR1
REAR_FAN1
REAR_FAN2
USBPW12
CPU_FAN2
4MbitFlashBIOS
PANEL1
Intel82541GIGigabitEthernet
SuperI/O
SB_PWR1
IntelE7210MCH
Intel6300ESB
ICH
CR2032 3VLithium Cell
CMOS Power
ATX12V1
KBPWR1
PR
OM
ISE
PD
C20
378
RA
IDC
ontr
olle
r
ATXPWR1
mP
GA
604
CPU2
PCI2 (32-bit, 33MHz 5V)
PCIX1 (64-bit, 66MHz 3V)
26.8cm (10.5in)
30.5
cm (
12in
)
mP
GA
604
CPU1
PCIX2 (64-bit, 66MHz 3V)
PCI1 (32-bit, 33MHz 5V)
PCI3 (32-bit, 33MHz 5V)
PS/2KBMST: MouseB: Keyboard
USBPW12
REAR_FAN2REAR_FAN1
VGA_EN1
LAN_EN2
PRI_IDE1
SEC_IDE1
FLOPPY1 PRI_RAID1
DDR DIMM_A1 (64 bit,184-pin module)
DDR DIMM_A2 (64 bit,184-pin module)
DDR DIMM_B1 (64 bit,184-pin module)
DDR DIMM_B2 (64 bit,184-pin module)
Intel82547GIGigabitEthernet
SA
TA1
SA
TA2
SA
TA_R
AID
1
SATA
_RAI
D2
RECOVERY1
RAID_EN1
FRNT_FAN1 FRNT_FAN2
DSW1
ATIRAGE XL
VGAController
RJ-45(LAN1)
RJ-45(LAN2)
COM2
CO
M1
VG
A1
USBPW34
CLRTC1
USB12
LAN_EN1
LPT1
USB34
BM
CS
OC
KE
T1
BPSMB1
BMCCONN1
CPU_FAN1
PCH-DR
AUX_PANEL1
BUZZER1
PSUSMB1
LED1
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) A - 5A - 5A - 5A - 5A - 5
NCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboard
NCLV-D motherboardNCLV-D motherboardNCLV-D motherboardNCLV-D motherboardNCLV-D motherboard
NCLV-D
FLOPPY1
8MbitFlashBIOS
SEC_IDE1
SuperI/O
IntelICH
6300ESB
PRI_IDE1
SSI12V1SSIPWR1
mP
GA
604
CPU1
PCIE3(x4 link)
PCIX1 (64-bit PCI-X)
26.8cm (10.5in)
30.5
cm (
12in
)
FRNT_FAN1
SATA1
FRNT_FAN2
PANEL1
SAT
A_R
AID
1
SB_PWR1
DDR DDR_B2 (64 bit,184-pin module)
DDR DDR_A2 (64 bit,184-pin module)
DDR DDR_B1 (64 bit,184-pin module)
DDR DDR_A1 (64 bit,184-pin module)
PCIX2 (64-bit PCI-X)
PCI4 (32-bit 5V PCI)
PCI5 (32-bit 5V PCI)
mP
GA
604
CPU2
AdaptecAIC-8130
PS/2KBMST: MouseB: Keyboard
VG
AC
OM
1
LAN1
LAN2
USB12
SAT
A_R
AID
2S
ATA
_RA
ID3
SAT
A_R
AID
4
SATA2
IntelMCH
E7320
ATIRAGE XL
VGAController
GigabitLAN
BCM5705E
COM2
LPT1
BPSMB1
BMCCONN1AUX_PANEL1
FM_CPU1
CPU_FAN1
FM_CPU2
CPU_FAN2
CLRTC1
8130 LED1
RECOVERY1
HDLED1
USBPW34
USB34
VGA_EN1
LAN_EN2
REAR_FAN2
REAR_FAN1
LAN_EN1
KBPWR1
USBPW12
PSUSMB1
SATA_EN1
CR2032 3VLithium Cell
CMOS Power
BMCSOCKET1
GigabitLAN
BCM5721
NCCH-DR
FLOPPY
8Mbi
tF
lash
BIO
S
SEC_IDE
SuperI/O
IntelICH
6300ESB
PRI_IDE
ATX12V1ATXPWR1
mP
GA
604
CPU2
PCI3 (32-bit, 33MHz 5V)
PCIX1 (64-bit, 66MHz 3V)
26.8cm (10.5in)
30.5
cm (
12in
)
FRNT_FAN1
SATA1
FRNT_FAN2
PANEL1
SAT
A_R
AID
1
SB_PWR1
CR2032 3VLithium Cell
CMOS Power
DDR DIMM_A1 (64 bit,184-pin module)
DDR DIMM_A2 (64 bit,184-pin module)
DDR DIMM_B1 (64 bit,184-pin module)
DDR DIMM_B2 (64 bit,184-pin module)
PCIX2 (64-bit, 66MHz 3V)
PCI4 (32-bit, 33MHz 5V)
PCI5 (32-bit, 33MHz 5V)
mP
GA
604
CPU1
AdaptecAIC-8130
PS/2KBMST: MouseB: Keyboard
VG
AC
OM
1
LAN1
LAN2
USB12
SAT
A_R
AID
2S
ATA
_RA
ID3
SAT
A_R
AID
4
SATA2
IntelMCH
E7210
ATIRAGE XL
VGAController
Intel82547GIGigabitEthernet
Intel82541GIGigabitEthernet
COM2
LPT1BPSMB1
BMCCONN1AUX_PANEL1
FM_CPU1 CPU_FAN1
FM_CPU2
CPU_FAN2
CLRTC1 8130 LED1RECOVERY
HDLED
USBPW34USB34
VGA_EN1
LAN_EN2
REAR_FAN1
REAR_FAN2
LAN_EN1
KBPWR1
USBPW12
PSUSMB1
SATA_EN1
BMCSOCKET1
A - 6A - 6A - 6A - 6A - 6 Append ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ion
PSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboard
PSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboard
4Mbi
tF
lash
BIO
S
SEC_IDE1
PANEL1
Intel82541GIGigabitEthernet
Sup
erI/O
adaptecAIC-7901X
USB2.0T: USB1B: USB2
Top:LAN1
PS/2KBMST: MouseB: Keyboard
PRI_IDE1
KBPWR1
REAR_FAN2
REAR_FAN1
LAN_LED1
SB_PWR1
ATXPWR1
PCIX1 (64-bit, 66MHz 3V)
25cm (9.8in)
30.5
cm (
12in
)
LAN2
Socket 478
DDR DIMM_B2 (64 bit,184-pin module)
DDR DIMM_B1 (64 bit,184-pin module)
DDR DIMM_A2 (64 bit,184-pin module)
DDR DIMM_A1 (64 bit,184-pin module)
LAN_EN1LAN_EN2
VGA_EN1
LOCATOR1
J4J5
ATX12V1
CPU_FAN2CPU_FAN1
FRONT_FAN1
FRONT_FAN2
ATIRAGE XL
VGAController
PCI3 (32-bit, 33MHz 5V)
FLOPPY1
SATA1
BM
CS
OC
KE
T1
ZC
RS
KT
1
SATA2
COM2
USB34
FPSMB1
BPSMB1
3568
34 1
SCSIA1
CLRTC1
CHASSIS1
BAT1
PSUSMB1Intel
82547GIGigabitEthernet
PCI2 (32-bit, 33MHz 5V)
SA
SI_
EN
1
J6
BUZZER1
PSCH-SR®
SATA
_RAI
D1SA
TA_R
AID2
SATA
_RAI
D3SA
TA_R
AID4
AdaptecAIC-8110X
CO
M1
VG
AIntel
E7210(Canterwood-ES)
MCH
Intel6300ESB
(Hance-Rapid)ICH
J2
FAN5
PSCH-LR
25cm (9.9in)
31.1
cm (
12.2
in)
BUZZER1
VG
A1
SB_PWR1
BMCSOCKET1CLRTC1
DDR DIMM_A1 (64/72 bit,184-pin module)
DDR DIMM_A2 (64/72 bit,184-pin module)
DDR DIMM_B1 (64/72 bit,184-pin module)
DDR DIMM_B2 (64/72 bit,184-pin module)
IntelCanterwood-ES
MCH
FLO
PP
Y1
PR
I_ID
E1
SE
C_I
DE
1
SuperI/O
So
cke
t 4
78
ATX Power Connector
CR2032 3VLithium Cell
CMOS Power
4MbitFirmware
Hub
SATA2
®
CO
M1
SATA1
FAN6
FAN2
FAN1
FAN3 FAN4
VGA_EN1RECOVERY1
KBPWR1
PS
2_K
B1
PS
2_M
S1
LAN_EN2
LAN_EN1
PCIX1
PCIX2
LAN1
LAN2
USB1
USB2
SW1
LOCLED1
CHASSIS1
J3BPSMB1
Intel82547GI
IntelHance-Rapid
ICH
ATX12V1
MLED1
ATIRAGE-XL
VGAController
PCI1
US
B34
PA
NE
L1
Intel82541GI
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) A - 7A - 7A - 7A - 7A - 7
A.3 Troubleshooting
This troubleshooting guide provides answers to some common problemswhich you may encounter while installing and/or using ASUS ASMB-LE.These problems requires simple troubleshooting that you can perform byyourself. Contact the Wireless LAN Technical Support if you encounterproblems not mentioned in this section.
Prob lemProb lemProb lemProb lemProb lem Solut ionSo lut ionSo lut ionSo lut ionSo lut ion
The loca l/centra l server cannotThe loca l/centra l server cannotThe loca l/centra l server cannotThe loca l/centra l server cannotThe loca l/centra l server cannotconnect to the ASMB-LE board .connect to the ASMB-LE board .connect to the ASMB-LE board .connect to the ASMB-LE board .connect to the ASMB-LE board .
1. Check if the LAN cable isconnected to the LAN port forserver management. See pageA-2 for details.
2. Check if the remote server LANport is working properly. If youhave not previously installed theLAN controller driver, install thesame using the system support CD.
3. Make sure the IP address of boththe remote and local/centralservers are on the same subnet.
4. Set the remote server IP addressand MAC address using the ASUSHost Management ControllerSetup. See Chapter 2 for details.
The ARC cannot rece ive PETThe ARC cannot rece ive PETThe ARC cannot rece ive PETThe ARC cannot rece ive PETThe ARC cannot rece ive PETinformat ion f rom the remoteinformat ion f rom the remoteinformat ion f rom the remoteinformat ion f rom the remoteinformat ion f rom the remotese rve r .se rve r .se rve r .se rve r .se rve r .
Set the remote server PET IP addressand MAC address using the ASUSServer Management Card Utility. SeeChapter 2 for details.
The ASMC ut i l i ty cannot setThe ASMC ut i l i ty cannot setThe ASMC ut i l i ty cannot setThe ASMC ut i l i ty cannot setThe ASMC ut i l i ty cannot setthe BMC MAC address orthe BMC MAC address orthe BMC MAC address orthe BMC MAC address orthe BMC MAC address orcannot enab le TCO.cannot enab le TCO.cannot enab le TCO.cannot enab le TCO.cannot enab le TCO.
Copy the n i c . i n in i c . i n in i c . i n in i c . i n in i c . i n i file to the ASMCdirectory, then try again. The n i c . i n in i c . i n in i c . i n in i c . i n in i c . i n ifile is available from the support CD.
A - 8A - 8A - 8A - 8A - 8 Append ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ion