52
ASMB-LE Server Management Board

Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASMB-LEServer Management Board

Page 2: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

i ii ii ii ii i

E1743E1743E1743E1743E1743

First edit ion V1First edit ion V1First edit ion V1First edit ion V1First edit ion V1November 2004November 2004November 2004November 2004November 2004

Copyright © 2004 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and software described in it, may be reproduced,transmitted, transcribed, stored in a retrieval system, or translated into any language in any formor by any means, except documentation kept by the purchaser for backup purposes, without theexpress written permission of ASUSTeK COMPUTER INC. (“ASUS”).

Product warranty or service will not be extended if: (1) the product is repaired, modified oraltered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2)the serial number of the product is defaced or missing.

ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHEREXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIESOR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.IN NO EVENT SHALL ASUS, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BELIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES(INCLUDING DAMAGES FOR LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USEOR DATA, INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS BEENADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT ORERROR IN THIS MANUAL OR PRODUCT.

SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHEDFOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIMEWITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS.ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS ORINACCURACIES THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTSAND SOFTWARE DESCRIBED IN IT.

Products and corporate names appearing in this manual may or may not be registeredtrademarks or copyrights of their respective companies, and are used only for identification orexplanation and to the owners’ benefit, without intent to infringe.

Page 3: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

i i ii i ii i ii i ii i i

Contents

Contents ............................................................................................. iii

Notices ................................................................................................. v

Safety information .............................................................................. vi

About this guide ................................................................................ vii

Typography ....................................................................................... viii

ASMB-LE specifications summary ....................................................... ix

Chapter 1:Chapter 1:Chapter 1:Chapter 1:Chapter 1: Product introductionProduct introductionProduct introductionProduct introductionProduct introduction

1.1 Welcome! .............................................................................. 1-2

1.2 Package contents ................................................................. 1-2

1.3 Board layout ......................................................................... 1-3

1.4 System requirements ........................................................... 1-3

1.5 Network setup ...................................................................... 1-4

Chapter 2:Chapter 2:Chapter 2:Chapter 2:Chapter 2: Instal lationInstal lationInstal lationInstal lationInstal lation

2.1 Before you proceed .............................................................. 2-2

2.2 Hardware installation ............................................................ 2-2

2.3 Network configuration .......................................................... 2-5

2.3.1 Running the ASMC utility ........................................ 2-5

2.3.2 Configuring the LAN controller ............................... 2-6

2.3.3 Updating the ASMC-LE firmware ............................ 2-8

2.4 Software installation ............................................................ 2-9

2.4.1 Installing the ARC ................................................... 2-9

2.4.2 Launching ARC...................................................... 2-10

Chapter 3:Chapter 3:Chapter 3:Chapter 3:Chapter 3: Software supportSoftware supportSoftware supportSoftware supportSoftware support

3.1 ASUS Remote Console (ARC) ............................................... 3-2

3.1.1 ARC sections .......................................................... 3-2

3.1.2 Connecting to the remote server ........................... 3-5

3.1.3 Retrieving sensor information ................................. 3-7

3.1.4 Displaying all remote server sensors ...................... 3-9

3.1.5 Displaying FRU information ................................... 3-10

3.1.6 Displaying system event logs ............................... 3-11

3.1.7 Adjusting the monitoring settings ........................ 3-12

3.1.8 Controlling the remote server power ................... 3-13

3.1.9 Viewing PET information ....................................... 3-14

Page 4: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

i vi vi vi vi v

Contents

3.2 ASUS Host Management Controller Setup .......................... 3-15

3.2.1 Installing and launching the ASUS HostManagement Controller Setup utility .................... 3-15

3.2.2 Command fields .................................................... 3-16

3.2.3 Initial ..................................................................... 3-16

3.2.4 View ...................................................................... 3-16

3.2.5 Set ........................................................................ 3-19

3.2.6 Monitor ................................................................. 3-20

3.2.7 Help ...................................................................... 3-20

Appendix:Appendix:Appendix:Appendix:Appendix: Reference informationReference informationReference informationReference informationReference information

A.1 LAN port for server management ........................................ A-2

A.2 BMC socket ........................................................................... A-4

A.3 Troubleshooting ................................................................... A-7

Page 5: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

vvvvv

Notices

Federal Communications Commission StatementFederal Communications Commission StatementFederal Communications Commission StatementFederal Communications Commission StatementFederal Communications Commission Statement

This device complies with Part 15 of the FCC Rules. Operation is subject tothe following two conditions:

• This device may not cause harmful interference, and

• This device must accept any interference received including interferencethat may cause undesired operation.

This equipment has been tested and found to comply with the limits for aClass B digital device, pursuant to Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses and can radiate radiofrequency energy and, if not installed and used in accordance withmanufacturer’s instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will notoccur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined byturning the equipment off and on, the user is encouraged to try to correctthe interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment to an outlet on a circuit different from that towhich the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

Canadian Department of Communications StatementCanadian Department of Communications StatementCanadian Department of Communications StatementCanadian Department of Communications StatementCanadian Department of Communications Statement

This digital apparatus does not exceed the Class B limits for radio noiseemissions from digital apparatus set out in the Radio InterferenceRegulations of the Canadian Department of Communications.

This class B digital apparatus complies with CanadianThis class B digital apparatus complies with CanadianThis class B digital apparatus complies with CanadianThis class B digital apparatus complies with CanadianThis class B digital apparatus complies with CanadianICES-003.ICES-003.ICES-003.ICES-003.ICES-003.

The use of shielded cables for connection of the monitor to the graphicscard is required to assure compliance with FCC regulations. Changes ormodifications to this unit not expressly approved by the partyresponsible for compliance could void the user’s authority to operatethis equipment.

Page 6: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

v iv iv iv iv i

Safety information

Electrical safetyElectrical safetyElectrical safetyElectrical safetyElectrical safety

• To prevent electrical shock hazard, disconnect the power cable fromthe electrical outlet before relocating the server.

• When adding or removing devices to or from the server, ensure thatthe power cables for the devices are unplugged before the signal cablesare connected. If possible, disconnect all power cables from the existingserver before you add a device.

• Before connecting or removing signal cables from the server, ensurethat all power cables are unplugged.

• Seek professional assistance before using an adapter or extension cord.These devices could interrupt the grounding circuit.

• Make sure that your power supply is set to the correct voltage in yourarea. If you are not sure about the voltage of the electrical outlet youare using, contact your local power company.

• If the power supply is broken, do not try to fix it by yourself. Contact aqualified service technician or your retailer.

Operation safetyOperation safetyOperation safetyOperation safetyOperation safety

• Before installing any component to the server, carefully read all themanuals that came with the package.

• Before using the product, make sure all cables are correctly connectedand the power cables are not damaged. If you detect any damage,contact your dealer immediately.

• To avoid short circuits, keep paper clips, screws, and staples away fromconnectors, slots, sockets and circuitry.

• Avoid dust, humidity, and temperature extremes. Do not place theproduct in any area where it may become wet.

• Place the product on a stable surface.

• If you encounter technical problems with the product, contact a qualifiedservice technician or your retailer.

Page 7: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

v i iv i iv i iv i iv i i

About this guide

This user guide contains the information you need when installing andconfiguring the server management card.

How this guide is organizedHow this guide is organizedHow this guide is organizedHow this guide is organizedHow this guide is organized

This manual contains the following parts:

••••• Chapter 1: Product introduct ionChapter 1: Product introduct ionChapter 1: Product introduct ionChapter 1: Product introduct ionChapter 1: Product introduct ion

This chapter describes the server management board features and thenew technologies it supports.

••••• Chapter 2: Insta l lat ionChapter 2: Insta l lat ionChapter 2: Insta l lat ionChapter 2: Insta l lat ionChapter 2: Insta l lat ion

This chapter provides instructions on how to install the board to theserver system and install the utilities that the board supports.

••••• Chapter 3: Software supportChapter 3: Software supportChapter 3: Software supportChapter 3: Software supportChapter 3: Software support

This chapter tells you how to use the software applications that theserver management board supports.

••••• Appendix: Troubleshoot ingAppendix: Troubleshoot ingAppendix: Troubleshoot ingAppendix: Troubleshoot ingAppendix: Troubleshoot ing

The Appendix lists the common problems that you may encounterwhen installing or usingthe server management board or any of thebundled utilities.

Where to find more informationWhere to find more informationWhere to find more informationWhere to find more informationWhere to find more information

Refer to the following sources for additional information and for productand software updates.

1 .1 .1 .1 .1 . ASUS webs itesASUS webs itesASUS webs itesASUS webs itesASUS webs ites

The ASUS website provides updated information on ASUS hardwareand software products. Refer to the ASUS contact information.

2 .2 .2 .2 .2 . Opt ional documentat ionOpt ional documentat ionOpt ional documentat ionOpt ional documentat ionOpt ional documentat ion

Your product package may include optional documentation, such aswarranty flyers, that may have been added by your dealer. Thesedocuments are not part of the standard package.

Page 8: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

v i i iv i i iv i i iv i i iv i i i

Typography

Bo l d t e x tBo l d t e x tBo l d t e x tBo l d t e x tBo l d t e x t Indicates a menu or an item to select.

Italics Used to emphasize a word or a phrase.

<Key> Keys enclosed in the less-than and greater-than sign meansthat you must press the enclosed key.

Example: <Enter> means that you must press the Enter orReturn key.

<Key1+Key2+Key3> If you must press two or more keys simultaneously, the

key names are linked with a plus sign (+).

Example: <Ctrl+Alt+D>

Command Means that you must type the command exactly as shown,then supply the required item or value enclosed inbrackets.

Example: At the DOS prompt, type the command line:afudos /i[filename]afudos /iP5GD2.ROM

DANGER/WARNING: DANGER/WARNING: DANGER/WARNING: DANGER/WARNING: DANGER/WARNING: Information to prevent injury to yourselfwhen trying to complete a task.

CAUTION:CAUTION:CAUTION:CAUTION:CAUTION: Information to prevent damage to the componentswhen trying to complete a task.

NOTE: NOTE: NOTE: NOTE: NOTE: Tips and additional information to help you complete atask.

IMPORTANT: IMPORTANT: IMPORTANT: IMPORTANT: IMPORTANT: Instructions that you MUST follow to complete atask.

Conventions used in this guideConventions used in this guideConventions used in this guideConventions used in this guideConventions used in this guide

To make sure that you perform certain tasks properly, take note of thefollowing symbols used throughout this manual.

Page 9: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

i xi xi xi xi x

ASMB-LE specifications summary

Specifications are subject to change without notice.

I P M II P M II P M II P M II P M I featu res featu res featu res featu res featu res

C P UC P UC P UC P UC P U

Ch ipsetCh ipsetCh ipsetCh ipsetCh ipset

Externa l BusExterna l BusExterna l BusExterna l BusExterna l BusAddress RangeAddress RangeAddress RangeAddress RangeAddress Range

Inte rna l RAMInterna l RAMInterna l RAMInterna l RAMInterna l RAM

Externa l RAMExterna l RAMExterna l RAMExterna l RAMExterna l RAM

F lash ROMF lash ROMF lash ROMF lash ROMF lash ROM

Inte r ruptIn te r ruptIn te r ruptIn te r ruptIn te r rupt

T imersT imersT imersT imersT imers

Sys temSystemSystemSystemSystemInte r faceIn te r faceIn te r faceIn te r faceIn te r face

Ser ia l /ModemSer ia l /ModemSer ia l /ModemSer ia l /ModemSer ia l /ModemInte r faceIn te r faceIn te r faceIn te r faceIn te r face

LAN Inte r faceLAN Inte r faceLAN Inte r faceLAN Inte r faceLAN Inte r face

B u sB u sB u sB u sB u s

Featu resFeatu resFeatu resFeatu resFeatu res

Sof twareSof twareSof twareSof twareSof twaresuppor tsuppor tsuppor tsuppor tsuppor t

IPMI 1.5-compliant and supports:- Auto monitoring sensor and event logging- IPMI Host I/O interface- Receiving and logging of event messages- IPMB/I2C system interface- System Watchdog Timer (ASR)

8-bit (80C32) 40 MHz

Winbond 83910

64 Kbyte (4-bank)

256 bytes

32 Kbytes

128 Kbytes

I2C, Timer, UART, RTC, LPC

16-bit system timerWatchdog timerReal Time Clock (RTC)

Low Pin CountSupports Keyboard Controller Style (KCS), ServerManagement Interface Chip (SMIC), and Block Transfer(BT) interfaces

Basic Mode and Terminal Mode

IPMI 1.5 Shared LAN

Four I2C busOne IPMB busTwo UART bus

Remote power on/offRemote rebootUpgradeable firmwareSNMP TrapDOS-based utility

ASUS Remote Console (ARC)ASUS Host Management Controller Utility (DOS-based)

Page 10: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

xxxxx

Page 11: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

1Productintroduction

This chapter describes the servermanagement board features and the newtechnologies it supports.

Page 12: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

1 - 21 - 21 - 21 - 21 - 2 Chapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ion

1.1 Welcome!

Thank you for buying an ASUSThank you for buying an ASUSThank you for buying an ASUSThank you for buying an ASUSThank you for buying an ASUS®®®®® ASMB-LE server management ASMB-LE server management ASMB-LE server management ASMB-LE server management ASMB-LE server managementboard !board !board !board !board !

The ASUS ASMB-LE is an Intelligent Platform Management Interface (IPMI)1.5-compliant board that allows you to monitor, control, and manage aremote server from the local or central server in your local area network(LAN).

With the proprietary ASUS Remote Console interface, ASMB-LE offersround-the-clock remote server monitoring through component sensorsincluding CPU(s) temperature(s), system temperature, fan rotations, andpower supply voltages. The ASMB-LE also records each remote serversystem event for accurate and efficient troubleshooting.

The ASMB-LE comes with a power management feature that allows you topower on/off or reset the remote server giving you full control of power incritical situations. The server management board also comes with a FieldReplaceable Unit (FRU) information feature that gathers information onreplaceable system components or modules such as the motherboard orbackplane model name, serial number, manufacturer, etc. You can use theFRU information when reporting and/or replacing server systemcomponents.

Before you start installing the server management board check the items inyour package with the list below.

If any of the above items is damaged or missing, contact your retailer.

1.2 Package contents

Check your server management board package for the following items.

� ASUS ASMB-LE board

� Support CD

� User guide

Page 13: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 1 - 31 - 31 - 31 - 31 - 3

1.3 Board layout

The ASUS ASMB-LE comes in a BMC package. The illustration below showsthe major components of the server management board.

LED indicatorsLED indicatorsLED indicatorsLED indicatorsLED indicators

The ASMB-LE board comes with two LED indicators: BMC heartbeat LEDand Power LED. Refer to the table below for the LED indications.

1.4 System requirements

Before you install the ASMB-LE board, check if your server system meetsthe following requirements:

• ASUS server motherboard with Baseboard Management Controller(BMC) socket*

• LAN (RJ-45) port for server management**

• Microsoft® Internet Explorer 5.5 or later

* Visit the ASUS website (www.asus.com) for an updated list of servermotherboards that support the ASMB-LE board.

** Refer to the Appendix section for details.

L E DL E DL E DL E DL E D N a m eN a m eN a m eN a m eN a m e S t a t u sS t a t u sS t a t u sS t a t u sS t a t u s Desc r i p t i onDesc r i p t i onDesc r i p t i onDesc r i p t i onDesc r i p t i on

L ED1LED1LED1LED1LED1 B M CB M CB M CB M CB M C Blinking ASMB-LE firmware is in execution.Hear tbeatHear tbeatHear tbeatHear tbeatHear tbeat Off The ASMB-LE firmware is corrupted or the

server system standby-power is off.

L ED2LED2LED2LED2LED2 Powe rPowe rPowe rPowe rPowe r On The managed server system is on.Off The managed server system is off.

S e r v e rS e r v e rS e r v e rS e r v e rS e r v e rmanagementmanagementmanagementmanagementmanagementc h i pc h i pc h i pc h i pc h i p

Boa rd connec to r sBoa rd connec to r sBoa rd connec to r sBoa rd connec to r sBoa rd connec to r s

F i rmwa re ch i pF i rmwa re ch i pF i rmwa re ch i pF i rmwa re ch i pF i rmwa re ch i p

Powe r LEDPowe r LEDPowe r LEDPowe r LEDPowe r LED

BMC hea r tbea t LEDBMC hea r tbea t LEDBMC hea r tbea t LEDBMC hea r tbea t LEDBMC hea r tbea t LED

* Connects to anIPMB connector onthe motherboard,when available.

Page 14: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

1 - 41 - 41 - 41 - 41 - 4 Chapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ionChapter 1 : Product int roduct ion

1.5 Network setup

The ASMB-LE server management board installed on the remote hostconnects to a local/central server via direct LAN connection or through anetwork hub. Below are the supported server management configurations.

Remote hos tRemote hos tRemote hos tRemote hos tRemote hos tw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LE

Loca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hASUS RemoteASUS RemoteASUS RemoteASUS RemoteASUS RemoteCont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)

Hub o r r ou te rHub o r r ou te rHub o r r ou te rHub o r r ou te rHub o r r ou te r

Direct LAN connectionDirect LAN connectionDirect LAN connectionDirect LAN connectionDirect LAN connection

LAN connection through a network hubLAN connection through a network hubLAN connection through a network hubLAN connection through a network hubLAN connection through a network hub

Remote hos tRemote hos tRemote hos tRemote hos tRemote hos tw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LEw i t h ASMB -LE

RJ -45 cab l eR J -45 cab l eR J -45 cab l eR J -45 cab l eR J -45 cab l e

Loca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hLoca l hos t w i t hASUS RemoteASUS RemoteASUS RemoteASUS RemoteASUS RemoteCont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)Cont ro l l e r (ARC)

Page 15: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

2Installation

This chapter provides instructions onhow to install the board to the serversystem and install the utilities that theboard supports.

Page 16: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

2 - 22 - 22 - 22 - 22 - 2 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion

2.2 Hardware installation

To install the server management board:

1. Remove the server systemcover, then locate theBaseboard ManagementController (BMC) socket on themotherboard.

2.1 Before you proceed

Take note of the following precautions before you install the servermanagement board to the server system.

• Unplug the server system power cord from the wall socket beforetouching any component.

• Use a grounded wrist strap or touch a safely grounded object or toa metal object, such as the power supply case, before handlingcomponents to avoid damaging them due to static electricity.

• Hold components by the edges to avoid touching the ICs on them.

• Whenever you uninstall any component, place it on a groundedantistatic pad or in the bag that came with the component.

• Before you insta l l o r remove any component , ensureBefore you insta l l o r remove any component , ensureBefore you insta l l o r remove any component , ensureBefore you insta l l o r remove any component , ensureBefore you insta l l o r remove any component , ensurethat the power supp ly i s sw itched off or the powerthat the power supp ly i s sw itched off or the powerthat the power supp ly i s sw itched off or the powerthat the power supp ly i s sw itched off or the powerthat the power supp ly i s sw itched off or the powercord i s detached f rom the power supp ly . cord i s detached f rom the power supp ly . cord i s detached f rom the power supp ly . cord i s detached f rom the power supp ly . cord i s detached f rom the power supp ly . Failure to do somay cause severe damage to the motherboard, peripherals, and/orcomponents.

2. Position the board at a 30º-45ºangle, then match the notch onthe board with the break on thesocket.

Refer to the Appendixsection for the location ofthe BMC socket on supportedmotherboards.

Page 17: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 2 - 32 - 32 - 32 - 32 - 3

3. Carefully push the board to thesocket until its connectors(golden fingers) arefully-inserted to the socket.

4. Press the board firmly until theBMC socket retaining clips snapback and secure the board inplace.

When installed, the boardappears as shown.

5. Re-install the server system cover, then connect the power plug to agrounded wall socket.

6. Insert the LAN cable plug to the LAN port for server management.

Refer to the Appendix for the location of the LAN port for servermanagement on various server motherboards.

7. For direct LAN configuration, connect the other end of the LAN cableto the local/central server LAN port.

For connection to a network hub or router, connect the other end ofthe LAN cable to the network hub or router.

Page 18: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

2 - 42 - 42 - 42 - 42 - 4 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion

To uninstall the board:

1. Simultaneously press the BMCsocket retaining clips outwarduntil the board tilts up.

2. Carefully pull the board outfrom the BMC socket, then setaside.

Page 19: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 2 - 52 - 52 - 52 - 52 - 5

2.3 Network configuration

You must configure the network settings of both the remote server andthe local/central server to establish communication and monitor or controlthe remote server. Prepare the support CD and a bootable floppy disk toconfigure the network settings.

2.3.12.3.12.3.12.3.12.3.1 Running the ASMC utilityRunning the ASMC utilityRunning the ASMC utilityRunning the ASMC utilityRunning the ASMC utility

The ASUS Server Management Card Utility allows you to know the MACaddress of the server motherboard and to set the IP address. This utility isavailable from the support CD that came with the package.

To run the ASMC utility:

1. Restart the remote server, then place the support CD to theoptical drive.

2. Press <1> (FreeDOS command prompt) when the screen prompts youto select from available boot options.

3. When the A:> prompt appears, type X: (where X is the drive letter ofthe optical drive).

4. When the X:> prompt appears, type cd\asms\asmc\le\dostool,then press <Enter>.

5. At the prompt, type asmc ?, then press <Enter> to display the ASMCUtility Help Menu. The screen appears as shown.

+-----------------------------------------------------+| ASUS Server Management Card Utility 1.00 Help Menu |+-----------------------------------------------------+Usage:ASMC -flash -save filenameASMC -flash -load filenameASMC -i2c_read bus_num dev_num offsetASMC -i2c_write bus_num dev_num offset data

ASMC -sdr -save filenameASMC -sdr -load filenameASMC -kcs[smic/bt/pci_smic] NetFn command data....ASMC -tco enable[disable]ASMC -bmc_ip ip_addr[10.10.10.20]ASMC -bmc_macASMC -pet_ip_mac ip_addr[10.10.10.20] mac_addr[010203040506]ASMC -bmc_info

Refer to the table on the next page for a description of the help menuoptions.

Page 20: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

2 - 62 - 62 - 62 - 62 - 6 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion

2.3.22.3.22.3.22.3.22.3.2 Configuring the LAN controllerConfiguring the LAN controllerConfiguring the LAN controllerConfiguring the LAN controllerConfiguring the LAN controller

Before you can establish connection to the ASMB-LE board, you mustconfigure the LAN port for server management being used by the remoteserver to connect to the local/central server.

To configure the LAN port of the remote server:

1. On the prompt, type asmc -tco enableasmc -tco enableasmc -tco enableasmc -tco enableasmc -tco enable, then press <Enter>. Thescreen displays the auto-detected information including themotherboard name, vendor-device code, and the physical address(MAC) of the remote server.

A:\>asmc -tco enableDetect MotherBoard -> (PSCH-LR)Detect KCS Interface

Bus Dev Fun Vendor-Device MAC======== ====== ======= ====== ============== ===================PSCH-LR 01 01 00 8086 - 1075 00-11-2F-0F-A2-21

Please shutdown the system (Standby power) to enable TCO mode!

A:\>

ASMC Help Menu optionsASMC Help Menu optionsASMC Help Menu optionsASMC Help Menu optionsASMC Help Menu options

Opt i o n sOp t i o n sOp t i o n sOp t i o n sOp t i o n s Desc r i p t i onDesc r i p t i onDesc r i p t i onDesc r i p t i onDesc r i p t i on

-flash -save filename Save the current firmware to a file

-flash -load filename Update the ASMB-LE firmware

-i2c_read bus_num dev_num offset Send the read I2C command

-i2c_write bus_num dev_num offset data Send the written I2C command

-sdr -save filename Save the SDR data to file

-sdr -load filename Update the SDR data from file

-kcs[smic/bt/pci_smic] NetFn command data.... Send IPMI command

-tco enable[disable] Enable or disable TCO mode

-bmc_ip ip_addr[10.10.10.20] Write the BMC IP address

-bmc_mac Auto-write the BMC MAC addresses

-pet_ip_mac ip_addr[10.10.10.20] mac_addr[010203040506] Write the PET destination IP and MAC addresses

-bmc_info Displays the BMC and PET IP and MACaddresses

2. Shutdown the remote server, then disconnect the power plug from theelectrical socket to enable the TCO mode.

3. Restart the remote server from the support CD.

The TCO (Total Cost Ownership) interface for Intel® Fast Ethernet andGigabit LAN controllers allows you to manage the remote server systemeven when its operating system is not fully functional.

Page 21: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 2 - 72 - 72 - 72 - 72 - 7

A:\>asmc -bmc_ip 169.254.137.105Detect MotherBoard -> (PSCH-LR)Detect KCS InterfaceNew BMC IP : 169.254.137.105

A:\>

4. Run the ASMC utility from the support CD following the instructions inthe previous section.

5. Type asmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxx, then press <Enter> toassign any IP address to the remote server LAN port. The screendisplays the request and response buffer. Write the remote server IPaddress in a piece of paper for reference.

A:\>asmc -bmc_macDetect MotherBoard -> (PSCH-LR)Detect KCS Interface

Bus Dev Fun Vendor-Device MAC======== ====== ======= ====== ============== ===================PSCH-LR 01 01 00 8086 - 1075 00-11-2F-0F-A2-21New BMC MAC: 00 11 2F 0F A2 21

A:\>

6. Type asmc -bmc_mac asmc -bmc_mac asmc -bmc_mac asmc -bmc_mac asmc -bmc_mac on the prompt, then press <Enter>. Thescreen displays the physical address (MAC) of the remote server.Write the MAC address in a piece of paper for reference.

When finished, the utility returns to the DOS prompt.

Make sure that the assigned IP address for both remote and local/centralservers are in the same subnet. You can use the network settings utilityin your OS to check.

7. Type asmc -bmc_info asmc -bmc_info asmc -bmc_info asmc -bmc_info asmc -bmc_info on the prompt, then press <Enter> todisplay the IP and MAC addresses of the BMC and PET.

8. Restart the remote server, enter the BIOS setup, then boot from thehard disk drive.

9. Adjust the local/central server network settings, if necessary.

A:\>asmc -bmc_macDetect MotherBoard -> (PSCH-LR)Detect KCS InterfaceBMC IP : 169.254.137.105BMC MAC: 00 11 2F 0F A2 21PET IP : 169.254.137.106PET MAC: 00 E0 18 9B BB 44

A:\>

Page 22: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

2 - 82 - 82 - 82 - 82 - 8 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion

2.3.32.3.32.3.32.3.32.3.3 Updating the ASMC-LE firmwareUpdating the ASMC-LE firmwareUpdating the ASMC-LE firmwareUpdating the ASMC-LE firmwareUpdating the ASMC-LE firmware

You can use the ASUS System Web-based Management (ASWM) applicationto update the ASMC-LE firmware. To do this:

1. Download the latest ASMB-LE firmware from the ASUS website(www.asus.com), then save the firmware file to the server.

2. Launch the ASWM application. If ASWM is not yet installed on yourserver system, use the support CD to install the application.

3. Click the Conf igurat ion Conf igurat ion Conf igurat ion Conf igurat ion Conf igurat ion link, then select IPMI F lash IPMI F lash IPMI F lash IPMI F lash IPMI F lash from the menu.

4. Click Browse Browse Browse Browse Browse to locate the latest firmware you downloaded earlier.When selected, the firmware path and filename appears in theF i rmware Image Name F i rmware Image Name F i rmware Image Name F i rmware Image Name F i rmware Image Name field.

5. Click App ly App ly App ly App ly App ly to update the ASMC-LE firmware.

33333

44444

55555

Page 23: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 2 - 92 - 92 - 92 - 92 - 9

2.4 Software installation

You can monitor, control, or manage the remote server from thelocal/central server using the ASUS Remote Console (ARC). The ARC is aweb-based application available from the support CD that came with theASMB-LE package. You must install the ARC on the local/central server toaccess the remote server.

2.4.12.4.12.4.12.4.12.4.1 Installing the ARCInstalling the ARCInstalling the ARCInstalling the ARCInstalling the ARC

To install the ARC to the local/central server:

1. Place the support CD to the optical drive. The CD automaticallydisplays the Dr iversDr iversDr iversDr iversDr ivers menu if Autorun is enabled in your computer.

If Autorun is NOT enabled in your computer, browse the contents of thesupport CD to locate the file ASSETUP.EXE from the BIN folder.Double-click the ASSETUP.EXE to run the CD.

2. Click the Management SoftwareManagement SoftwareManagement SoftwareManagement SoftwareManagement Software tab, then click the item Insta l l Insta l l Insta l l Insta l l Insta l lASUS IPMI Remote Console ut i l i tyASUS IPMI Remote Console ut i l i tyASUS IPMI Remote Console ut i l i tyASUS IPMI Remote Console ut i l i tyASUS IPMI Remote Console ut i l i ty.

Page 24: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

2 -102 -102 -102 -102 -10 Chapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ionChapter 2 : Insta l l at ion

3. Follow the installation wizard instructions to install the utility.

2.4.22.4.22.4.22.4.22.4.2 Launching ARCLaunching ARCLaunching ARCLaunching ARCLaunching ARC

To launch the ARC utility:

Click Start Start Start Start Start > Al l Programs Al l Programs Al l Programs Al l Programs Al l Programs > ASUS Remote Console ASUS Remote Console ASUS Remote Console ASUS Remote Console ASUS Remote Console > ASUSASUSASUSASUSASUSRemote ConsoleRemote ConsoleRemote ConsoleRemote ConsoleRemote Console from the Windows® desktop.

or

Double-click the ASUS RemoteConsole icon on the Windows®

desktop.

Page 25: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3Softwaresupport

This chapter tells you how to use thesoftware applications that the servermanagement board supports.

Page 26: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 - 23 - 23 - 23 - 23 - 2 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

3.1 ASUS Remote Console (ARC)

The ASUS Remote Console (ARC) is a web-based utility that allows you tomonitor the remote host’s hardware information including temperatures,fan rotations, voltages, and power. This application also lets you instantlypower on/off or reset the remote server.

The ARC window is made up of six sections: Menu Menu Menu Menu Menu bar, Tool Tool Tool Tool Tool bar,Navigation Navigation Navigation Navigation Navigation window, Detai l/SEL Detai l/SEL Detai l/SEL Detai l/SEL Detai l/SEL window, Event Event Event Event Event window, and Status Status Status Status Status bar.

3.1.13.1.13.1.13.1.13.1.1 ARC sectionsARC sectionsARC sectionsARC sectionsARC sections

Menu barMenu barMenu barMenu barMenu bar

The Menu bar contains all the commands for the ARC application. Click on amenu to display a list of available commands.

Menu ba rMenu ba rMenu ba rMenu ba rMenu ba rToo l b a rToo l b a rToo l b a rToo l b a rToo l b a r

Nav i ga t i onNav i ga t i onNav i ga t i onNav i ga t i onNav i ga t i onw i n d o ww i n d o ww i n d o ww i n d o ww i n d o w

Deta i l /SEL w i ndowDeta i l /SEL w i ndowDeta i l /SEL w i ndowDeta i l /SEL w i ndowDeta i l /SEL w i ndow

Even t w i ndowEven t w i ndowEven t w i ndowEven t w i ndowEven t w i ndow

Sta tu s ba rS t a tu s ba rS t a tu s ba rS t a tu s ba rS t a tu s ba r

M e n uM e n uM e n uM e n uM e n u Ava i l ab l e commandsAva i l ab l e commandsAva i l ab l e commandsAva i l ab l e commandsAva i l ab l e commands

S e r v e rS e r v e rS e r v e rS e r v e rS e r v e r add, delete, connect, disconnect server or change the server settings

V i e wV i e wV i e wV i e wV i e w show or hide the tool bar, status bar, navigation, and PET windows

Con t r o lCon t r o lCon t r o lCon t r o lCon t r o l turn on/off or reset the remote server

E d i tE d i tE d i tE d i tE d i t delete the System Event Log (SEL) or PET log

H e l pH e l pH e l pH e l pH e l p view information about the ARC application

Tool barTool barTool barTool barTool bar

The Tool bar contains buttons corresponding to the most commonly usedcommands. The Tool bar offers faster access and execution of thesecommands. Move the mouse pointer over a button to display its function.

Page 27: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 - 33 - 33 - 33 - 33 - 3

Navigation windowNavigation windowNavigation windowNavigation windowNavigation window

The Navigation window displays the directory ofconnected and disconnected remote server(s).For multiple monitoring, this window allows you tonavigate through the remote servers. Click theAl l Servers Al l Servers Al l Servers Al l Servers Al l Servers root directory to display allconnected and disconnected servers, then clickon the server you want to monitor or control.

Click before the server connection to display available remote serverinformation including the Sensor Data Record (SDR), Field Replaceable Unit(FRU), and System Event Log (SEL).

Some remote server information (such as the SDR) contains several sensorgroups such as TemperatureTemperatureTemperatureTemperatureTemperature, Vo l tageVo ltageVo ltageVo ltageVo ltage, F a nF anFanFanFan, and Chass is Intrus ionChass is Intrus ionChass is Intrus ionChass is Intrus ionChass is Intrus ion.Click before the remote server information to display the sensor groups.

Click before a sensor group to display individual sensors. For example,clicking before the sensor group Temperature Temperature Temperature Temperature Temperature displays the CPU1 andsystem temperatures.

You can also change the server directorydisplay by clicking the buttons on top of thewindow. For example, clicking the I P I P I P I P I P buttondisplays the remote server IP address insteadof the remote server name (NNNNN). Selecting I DI DI DI DI Ddisplays the remote server ID instead of theserver name or IP address.

Senso r g roupsSenso r g roupsSenso r g roupsSenso r g roupsSenso r g roups SensorsSensorsSensorsSensorsSensors

Page 28: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 - 43 - 43 - 43 - 43 - 4 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

Event windowEvent windowEvent windowEvent windowEvent window

The Event window displays the Platform Event Trap (PET) received by theARC. The PET information includes the event index, source IP address,enterprise, community, generic and specific traps, and time ticks. The PETinformation is a system management alert in SNMP Trap format and is usedis used for IPMI alerting as well as alerts using the ASF specification.

Status barStatus barStatus barStatus barStatus bar

The Status bar located at the bottom of the ARC window displays theconnection status to the remote server, connection duration, IP address ofthe remote server, and the progress of SDR/SEL/FRU informationdownload.

Detail/SEL windowDetail/SEL windowDetail/SEL windowDetail/SEL windowDetail/SEL window

The Detail/SEL window displays the detailed SDR and FRU information, andthe System Event Log (SEL). The window provides the link for detailedsensor information or system events and allows you to adjust the sensorthreshold values.

Page 29: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 - 53 - 53 - 53 - 53 - 5

3.1.23.1.23.1.23.1.23.1.2 Connecting to the remote serverConnecting to the remote serverConnecting to the remote serverConnecting to the remote serverConnecting to the remote server

To connect to the remote server:

1. From the menu bar, clickServerServerServerServerServer, then select NewNewNewNewNew. AnAdd new serverAdd new serverAdd new serverAdd new serverAdd new serverconnect ion connect ion connect ion connect ion connect ion window appears.

2. Type the remote server nameand IP address on the fields.Click Save Defau ltSave Defau ltSave Defau ltSave Defau ltSave Defau lt to set theremote server connection asthe default. Otherwise, clickO KO KO KO KO K to continue or Cance l Cance l Cance l Cance l Cance l toclose the window.

The default server connection name and IP address are automaticallydisplayed everytime you add a new server connection.

3. When prompted, select I PM II PM II PM II PM II PM IServerServerServerServerServer, then click Cont inueCont inueCont inueCont inueCont inue.

Page 30: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 - 63 - 63 - 63 - 63 - 6 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

The navigation window displays the remote server. The available remoteserver information are displayed on the Detail/SEL window.

4. Click before the remote server to display the remote serverinformation, then select from the list. You can also double-click aremote server information from the Detail/SEL window.

5. When prompted, enter thedefault user name (adm) andpassword (asusadm).

6. Set the connection requestlevel authentication andprivilege, then click O KO KO KO KO K.

The default connection request level authentication is MD2 MD2 MD2 MD2 MD2 (MessageDigest Algorithm 2) with Admin i s t rator Admin i s t rator Admin i s t rator Admin i s t rator Admin i s t rator privileges. You may changethese configuration according to your network settings or preference.

Page 31: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 - 73 - 73 - 73 - 73 - 7

3.1.33.1.33.1.33.1.33.1.3 Retrieving sensor informationRetrieving sensor informationRetrieving sensor informationRetrieving sensor informationRetrieving sensor information

The Sensor Data Record (SDR) provides remote server system informationthrough available sensors including CPU/system/power temperatures,voltages, fan speeds, chassis intrusion, etc. The SDR also providesinformation on the sensor location (e.g. CPU1, CPU2, FAN1), eventgeneration, and access information.

To retrieve a sensor information:

1. From the navigation window, click before the server name todisplay the remote server information.

2. Click before the SDR SDR SDR SDR SDR to display the sensor groups (e.g.Temperature), then click before a sensor group to display theindividual sensors. Select a sensor (e.g. CPU1 THERMAL) to display itsvalues in the Detail/SEL window.

The Detail/SEL window displays the sensor data attributes, values,and meanings. From this window, you can adjust the sensor thresholdvalues by clicking the up/down arrow button after each value.

Page 32: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 - 83 - 83 - 83 - 83 - 8 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

3. Click Mo reMoreMoreMoreMore. A sensor windowappears displaying additionalinformation on the sensor.

The Informat ion Informat ion Informat ion Informat ion Informat ion tab displaysbasic sensor informationincluding the sensor name,current status, current value,and sensor type.

The tab also displays thesensor record ID and SDRversion.

4. Click the Sett ings Sett ings Sett ings Sett ings Sett ings tab toadjust the sensor thresholdvalues. Click on the up/downarrow button after eachthreshold value to adjust.

Click O K O K O K O K O K to close the window.

Page 33: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 - 93 - 93 - 93 - 93 - 9

3.1.43.1.43.1.43.1.43.1.4 Displaying all remote server sensorsDisplaying all remote server sensorsDisplaying all remote server sensorsDisplaying all remote server sensorsDisplaying all remote server sensors

To display all remote server sensors in graphical format:

1. From the navigation window, click before the server name to openthe remote server information.

2. Click Al l Sensors va lueAl l Sensors va lueAl l Sensors va lueAl l Sensors va lueAl l Sensors va lue. All remote server sensors are displayed onthe Information window in graphical format.

The color bar represents the upper/lower threshold values of eachsensor. The green pointer indicates the current value of the sensor.

Page 34: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 -103 -103 -103 -103 -10 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

3.1.53.1.53.1.53.1.53.1.5 Displaying FRU informationDisplaying FRU informationDisplaying FRU informationDisplaying FRU informationDisplaying FRU information

The Field Replaceable Unit (FRU) information provides the manufacturer,product name, and/or serial number of various modules and componentsinstalled on the remote server. For example, the FRU feature can displaythe remote server motherboard name, model, and serial number. You canuse this feature when retrieving information on a module or componentinstalled on the remote server.

The FRU information feature allows you to obtain component or moduleinformation even when the remote server is down or off.

To display the FRU information:

1. From the navigation window, click before the server name to openthe remote server information.

2. Click before the FRU FRU FRU FRU FRU to display available FRU information, then click before the module/component. Select a module or component from

the list to display the FRU information in the Detail/SEL window.

Page 35: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -113 -113 -113 -113 -11

3.1.63.1.63.1.63.1.63.1.6 Displaying system event logsDisplaying system event logsDisplaying system event logsDisplaying system event logsDisplaying system event logs

The System Event Log (SEL) is a non-volatile storage area where all remoteserver system events are stored for real-time tracking or later retrieval.The ARC application can display system events for efficient remote servermonitoring and troubleshooting.

To display the sytem events:

1. From the navigation window, click before the server connection,then click S ELSELSELSELSEL. The status bar displays the progress of the SELdownload. When finished, the Detail/SEL window displays the systemevents in chronological order.

2. Double-click an event todisplay an EventEventEventEventEventInformat ion Informat ion Informat ion Informat ion Informat ion window.

This window displays thesensor type and record ID,event message, current andthreshold values, and othersystem event information.

3. Click OK to close the window.

Page 36: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 -123 -123 -123 -123 -12 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

3.1.73.1.73.1.73.1.73.1.7 Adjusting the monitoring settingsAdjusting the monitoring settingsAdjusting the monitoring settingsAdjusting the monitoring settingsAdjusting the monitoring settings

The ARC application allows you to adjust the remote server monitoringsettings including SEL polling, SDR reading, ASF, and PET.

To adjust the monitoring settings:

1. Click Server Server Server Server Server on the menu bar,then select Sett ing Sett ing Sett ing Sett ing Sett ing from thedrop-down menu. A ServerServerServerServerServerSett ing Sett ing Sett ing Sett ing Sett ing window appears.

2. Click on the up/down arrowbutton after each setting toadjust the value.

3. Click O K O K O K O K O K to save your changesand close the window.

Otherwise, click Cance lCance lCance lCance lCance l toignore your changes.

Page 37: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -133 -133 -133 -133 -13

3.1.83.1.83.1.83.1.83.1.8 Controlling the remote server powerControlling the remote server powerControlling the remote server powerControlling the remote server powerControlling the remote server power

The ASMB-LE board through the ARC application allows you to power up,power down, or reset the remote server using the power menu.

2. Click Yes Yes Yes Yes Yes when the Conf i rmConf i rmConf i rmConf i rmConf i rmpower down power down power down power down power down window appears.

3. The remote server is turned off.Click O K O K O K O K O K to close the window.

Use the same instructions asreference when powering up orresetting the remote server.

Before turning off or resetting the remote server, make sure that it isnot being used and that no application is currently running to avoid dataloss.

To power down the remote server:

1. Click Contro l Contro l Contro l Contro l Contro l on the menu bar,then select Power downPower downPower downPower downPower downfrom the drop-down menu.

O RO RO RO RO R

Click the power down button onthe tool bar.

Page 38: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 -143 -143 -143 -143 -14 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

3.1.93.1.93.1.93.1.93.1.9 Viewing PET informationViewing PET informationViewing PET informationViewing PET informationViewing PET information

The Platform Event Trap or PET is an SNMP trap used for systemmanagement alerts. When the ARC receives a PET, it displays a pop-upwindow notifying you of the alert and its source (IP address). Right-clickthe window to close.

You need to install an SNMP service to the remote server to receivePET information.

Important not ice for WindowsImportant not ice for WindowsImportant not ice for WindowsImportant not ice for WindowsImportant not ice for Windows®®®®® XP (Serv ice Pack 2) users XP (Serv ice Pack 2) users XP (Serv ice Pack 2) users XP (Serv ice Pack 2) users XP (Serv ice Pack 2) users

If the remote server system is behind a firewall, you must create a UDPport to receive PET information.

To create a UDP port:

1. Double-click the My ComputerMy ComputerMy ComputerMy ComputerMy Computer icon from the Windows® desktop,then click the My Network P lacesMy Network P lacesMy Network P lacesMy Network P lacesMy Network P laces link.

2. Click the View network connect ionsView network connect ionsView network connect ionsView network connect ionsView network connect ions link, then select the LANconnection the remote server system is using.

3. Right-click the LAN connection, then select Propert ies Propert ies Propert ies Propert ies Propert ies from thedrop-down menu.

4. Click the Advanced Advanced Advanced Advanced Advanced tab, then click the Sett ings Sett ings Sett ings Sett ings Sett ings button.

5. On the Serv ices Serv ices Serv ices Serv ices Serv ices tab, click the Add Add Add Add Add button to display a Serv iceServ iceServ iceServ iceServ iceSett ings Sett ings Sett ings Sett ings Sett ings window.

6. Type a name on the Descr ipt ion of service f ie ldDescr ipt ion of service f ie ldDescr ipt ion of service f ie ldDescr ipt ion of service f ie ldDescr ipt ion of service f ie ld (i.e. ASUS ARC).

7. Type the IP address of the local/central server, then set the Externa lExterna lExterna lExterna lExterna land Interna l Port number Interna l Port number Interna l Port number Interna l Port number Interna l Port number to 162162162162162.

8. Select U D PU D PU D PU D PU D P, then click O KO KO KO KO K. The created service is displayed in theServices list. Check the box before the service, then click O KO KO KO KO K.

You must also adjust the Internet Explorer settings to allow active contentsto run in the local/central server. To do this:

1. From the Internet Explorer Internet Explorer Internet Explorer Internet Explorer Internet Explorer menu, click Too l sToo l sToo l sToo l sToo l s, then selectInternet Opt ionsInternet Opt ionsInternet Opt ionsInternet Opt ionsInternet Opt ions from the drop-down menu.

2. Click the Advanced Advanced Advanced Advanced Advanced tab.

3. Enable the item “Allow active content to run in files on My ComputerAllow active content to run in files on My ComputerAllow active content to run in files on My ComputerAllow active content to run in files on My ComputerAllow active content to run in files on My Computer”.

4. Click the App ly App ly App ly App ly App ly button, then click OK OK OK OK OK to close the window.

Page 39: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -153 -153 -153 -153 -15

3.2 ASUS Host Management Controller Setup

The ASUS Host Management Controller Setup utility provides preciseconfiguration and basic functions including System Event Log (SEL)generation and System Data Record (SDR) reading in DOS mode.

This utility also supplies configuration sequences for the type of hostinterface as well as direct real-time monitoring of system informationincluding CPU temperature(s), fan speeds and system voltages.

3.2.13.2.13.2.13.2.13.2.1 Installing and launching the ASUS HostInstalling and launching the ASUS HostInstalling and launching the ASUS HostInstalling and launching the ASUS HostInstalling and launching the ASUS HostManagement Controller Setup utilityManagement Controller Setup utilityManagement Controller Setup utilityManagement Controller Setup utilityManagement Controller Setup utility

To install the ASUS Host Management Controller Setup utility:

1. Boot the server in DOS mode using the support CD.

2. When the A:> prompt appears, type X: (where X is the drive letter ofthe optical drive).

3. When the X:> prompt appears, type cd\asms\asmc\le\dostool,then press <Enter>.

4. At the prompt, type asmc, then press <Enter> to display the ASMCUtility Help Menu. The screen appears as shown.

5. The main utility screen appears. Press <Enter>.

A:\>E:

E:\>cd\asms\asmc\le\dostool

E:\cd\asms\asmc\le\dostool>asmc

Page 40: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 -163 -163 -163 -163 -16 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

3.2.23.2.23.2.23.2.23.2.2 Command fieldsCommand fieldsCommand fieldsCommand fieldsCommand fields

The utility menu bar has five commands: Initial, View, Set, Monitor andHelp. You can select a command using the left or right arrow button on thekeyboard. After selecting a command, use the down arrow key to displayavailable options. Select a command, then press <Enter> to execute.

3.2.43.2.43.2.43.2.43.2.4 ViewViewViewViewView

The V iew V iew V iew V iew V iew command displays the Baseboard Management Controller (BMC)data record including the System Event Log System Event Log System Event Log System Event Log System Event Log (SEL), the System DataSystem DataSystem DataSystem DataSystem DataRecord Record Record Record Record (SDR), and general BMC information.

3.2.33.2.33.2.33.2.33.2.3 InitialInitialInitialInitialInitial

The Initial command allows you to clear the SEL information or exit theutility.

Go to In i t ia l In i t ia l In i t ia l In i t ia l In i t ia l command, then select C lear SEL C lear SEL C lear SEL C lear SEL C lear SEL to empty all System EventLog information for a refresh set of data records. Use the C lear SELClear SELClear SELClear SELClear SELcommand when creating a new log that begins at an exact time for precisesystem monitoring.

Select Ex i t Ex i t Ex i t Ex i t Ex i t to close the utility and return to the DOS prompt.

Menu op t i onsMenu op t i onsMenu op t i onsMenu op t i onsMenu op t i onsMenu ba rMenu ba rMenu ba rMenu ba rMenu ba r

Page 41: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -173 -173 -173 -173 -17

To view the System Data Record (SDR):To view the System Data Record (SDR):To view the System Data Record (SDR):To view the System Data Record (SDR):To view the System Data Record (SDR):

1. Select BMC SDRBMC SDRBMC SDRBMC SDRBMC SDR from the V iew V iew V iew V iew V iew command option, then press<Enter>. A complete list of data records appears on the left pane. Theright pane displays the sensor data information.

The number on the bottom left of the screen indicates the datarecord displayed in the right window pane over the total number ofsensor data records in the remote host.

2. Use the down arrow key to display the next sensor data record.

3. Press <Esc> to return to the main screen.

To view the System Event Log (SEL):To view the System Event Log (SEL):To view the System Event Log (SEL):To view the System Event Log (SEL):To view the System Event Log (SEL):

1. Select BMC SDRBMC SDRBMC SDRBMC SDRBMC SDR from the V iew V iew V iew V iew V iew command option, then press<Enter>. A complete list of system event records appear on the leftpane. The right pane displayes the SEL information.

The number on the left bottom of the window shows the systemevent displayed in the right window pane over the total number ofsystem events in the remote host.

2. Use the down arrow key to display the next sensor event.

3. Press <Esc> to return to the main screen.

Page 42: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 -183 -183 -183 -183 -18 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

To view the BMC information:To view the BMC information:To view the BMC information:To view the BMC information:To view the BMC information:

1. Select BMC InfoBMC InfoBMC InfoBMC InfoBMC Info from the V iew V iew V iew V iew V iew command option, then press<Enter>. A list of BMC information appears on the left pane.

2. Use the down arrow button to select a BMC information. The BMCinformation is displayed in the right pane.

3. Press <Esc> to return to the main screen.

Page 43: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) 3 -193 -193 -193 -193 -19

3.2.53.2.53.2.53.2.53.2.5 SetSetSetSetSet

The Set Set Set Set Set command controls the host interface type and the correct BMC time.

You can select from the following interfaces:

KCS InterfaceKCS InterfaceKCS InterfaceKCS InterfaceKCS Interface - Keyboard Controller Style

SMIC InterfaceSMIC InterfaceSMIC InterfaceSMIC InterfaceSMIC Interface - Server Management Interface Chip

BF InterfaceBF InterfaceBF InterfaceBF InterfaceBF Interface - Block Transfer

PCI InterfacePCI InterfacePCI InterfacePCI InterfacePCI Interface - Peripheral Component Interconnect

3. When finished, press <Esc> to return to the main screen.

To set the BMC Timer:To set the BMC Timer:To set the BMC Timer:To set the BMC Timer:To set the BMC Timer:

1. Select BMC T imerBMC T imerBMC T imerBMC T imerBMC T imer from the Set Set Se t Se t Se t command option, then press<Enter>.

2. Set the BMC IPMI timer to the current system time.

3. When finished, press <Esc> to return to the main screen.

To select the host interface:To select the host interface:To select the host interface:To select the host interface:To select the host interface:

1. Select Host InterfaceHost InterfaceHost InterfaceHost InterfaceHost Interface from the Set Se t Se t Se t Se t command option, then press<Enter>. The screen displays the host interfaces supported by theserver management board.

2. Use the down arrow button to select a host interface, then press <Enter>.

Page 44: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

3 -203 -203 -203 -203 -20 Chapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software supportChapter 3 : Software support

3.2.73.2.73.2.73.2.73.2.7 HelpHelpHelpHelpHelp

The He lp He lp He lp He lp He lp command displays the available utility options, utility version,and copyright information.

3.2.63.2.63.2.63.2.63.2.6 MonitorMonitorMonitorMonitorMonitor

The Mon itor Mon itor Mon itor Mon itor Mon itor command displays real-time data on the remote serversystem and CPU temperatures, voltages, and fan speeds.

To display a remote server information:To display a remote server information:To display a remote server information:To display a remote server information:To display a remote server information:

1. Select a sensor from the Mon itor Mon itor Mon itor Mon itor Mon itor command options, then press<Enter>. A list of server information appears on the left pane.

2. Use the down arrow button to select a monitor information. Theselected monitor information details are displayed in the right pane.

3. Press <Esc> to return to the main screen.

Page 45: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

AReferenceinformation

The Appendix shows the location of theLAN port for server management onseveral motherboards and presentscommon problems that you mayencounter when installing or using theserver management board.

Page 46: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

A - 2A - 2A - 2A - 2A - 2 Append ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ion

A.1 LAN port for server management

The ASUS server motherboards that support the ASMB-LE comes with twoLAN (RJ-45) ports: one for network connection and the other for servermanagement. You must identify and use the LAN port for servermanagement to connect the remote server to the local/central host (directLAN connection) or to the network hub or router.

Refer to the illustrations below to identify the LAN port for servermanagement on different server motherboards.

NCL-DS motherboardNCL-DS motherboardNCL-DS motherboardNCL-DS motherboardNCL-DS motherboard

PCH-DR motherboardPCH-DR motherboardPCH-DR motherboardPCH-DR motherboardPCH-DR motherboard

NCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboard

Page 47: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) A - 3A - 3A - 3A - 3A - 3

NCLV-D motherboardNCLV-D motherboardNCLV-D motherboardNCLV-D motherboardNCLV-D motherboard

PSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboard

PSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboard

Page 48: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

A - 4A - 4A - 4A - 4A - 4 Append ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ion

A.2 BMC socket

The ASUS server motherboards that support the ASMB-LE comes with aBaseboard Management Card (BMC) socket.

Refer to the illustrations below to locate the BMC socket on differentserver motherboards.

NCL-DS motherboardNCL-DS motherboardNCL-DS motherboardNCL-DS motherboardNCL-DS motherboard

PCH-DR motherboardPCH-DR motherboardPCH-DR motherboardPCH-DR motherboardPCH-DR motherboard

AMI8MbFWH

KBPWR1

J2

ATXPWR1

SATA1

CPU_FAN2

®

FM_CPU2

SEC_IDE

FLOPPY1

ATIRAGE XL

VGAController

SCSIA1

PCI6 (32-bit, 33MHz 5V) BUZZ1

3568

34 1

DDR DIMM_A1 (64/72 bit, 240-pin module)

COM2

SuperI/O

PCIX1 (64-bit, 133MHz 3V)

CR2032 3VLithium Cell

CMOS Power

PANEL1

FRNT_FAN1

mP

GA

604

NC

L-D

S

PS/2T: MouseB: Keyboard

USB1USB2

COM1

PAR

AL

LE

L P

OR

T

VGA1

RJ-45(LAN-1)

RJ-45(LAN-2)

DDR DIMM_B1 (64/72 bit, 240-pin module)

DDR DIMM_A2 (64/72 bit, 240-pin module)

DDR DIMM_B2 (64/72 bit, 240-pin module)

DDR DIMM_A3 (64/72 bit, 240-pin module)

DDR DIMM_B3 (64/72 bit, 240-pin module)

DDR DIMM_A4 (64/72 bit, 240-pin module)

DDR DIMM_B4 (64/72 bit, 240-pin module)

mP

GA

604

33cm (13in)

30.5

cm (

12in

)

PRI_IDE

SCSIB1

FRNT_FAN2

SATA2

ATX12V1

CPU_FAN1

FM_CPU1

PCIX2 (64-bit, 133MHz 3V)

PCIX4 (64-bit, 133MHz 3V)

PCIX5 (64-bit, 133MHz 3V)

IntelICH5R

AdaptecAIC-7902W

Intel E7520MCH

BMCCONN1

PSUSMB1

BPSMB1

IntelPXH

IntelPXH

AUX_PANEL1

HDLED1SCSI_EN1

USB34

US

BP

W34

CLRTC1

PCIE3VGA_EN1

RECPVERY1LAN1_EN1

LAN2_EN1

BroadcomBCM5721

BroadcomBCM5721

SB_PWR1

REAR_FAN1

REAR_FAN2

USBPW12

CPU_FAN2

4MbitFlashBIOS

PANEL1

Intel82541GIGigabitEthernet

SuperI/O

SB_PWR1

IntelE7210MCH

Intel6300ESB

ICH

CR2032 3VLithium Cell

CMOS Power

ATX12V1

KBPWR1

PR

OM

ISE

PD

C20

378

RA

IDC

ontr

olle

r

ATXPWR1

mP

GA

604

CPU2

PCI2 (32-bit, 33MHz 5V)

PCIX1 (64-bit, 66MHz 3V)

26.8cm (10.5in)

30.5

cm (

12in

)

mP

GA

604

CPU1

PCIX2 (64-bit, 66MHz 3V)

PCI1 (32-bit, 33MHz 5V)

PCI3 (32-bit, 33MHz 5V)

PS/2KBMST: MouseB: Keyboard

USBPW12

REAR_FAN2REAR_FAN1

VGA_EN1

LAN_EN2

PRI_IDE1

SEC_IDE1

FLOPPY1 PRI_RAID1

DDR DIMM_A1 (64 bit,184-pin module)

DDR DIMM_A2 (64 bit,184-pin module)

DDR DIMM_B1 (64 bit,184-pin module)

DDR DIMM_B2 (64 bit,184-pin module)

Intel82547GIGigabitEthernet

SA

TA1

SA

TA2

SA

TA_R

AID

1

SATA

_RAI

D2

RECOVERY1

RAID_EN1

FRNT_FAN1 FRNT_FAN2

DSW1

ATIRAGE XL

VGAController

RJ-45(LAN1)

RJ-45(LAN2)

COM2

CO

M1

VG

A1

USBPW34

CLRTC1

USB12

LAN_EN1

LPT1

USB34

BM

CS

OC

KE

T1

BPSMB1

BMCCONN1

CPU_FAN1

PCH-DR

AUX_PANEL1

BUZZER1

PSUSMB1

LED1

Page 49: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) A - 5A - 5A - 5A - 5A - 5

NCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboardNCCH-DR motherboard

NCLV-D motherboardNCLV-D motherboardNCLV-D motherboardNCLV-D motherboardNCLV-D motherboard

NCLV-D

FLOPPY1

8MbitFlashBIOS

SEC_IDE1

SuperI/O

IntelICH

6300ESB

PRI_IDE1

SSI12V1SSIPWR1

mP

GA

604

CPU1

PCIE3(x4 link)

PCIX1 (64-bit PCI-X)

26.8cm (10.5in)

30.5

cm (

12in

)

FRNT_FAN1

SATA1

FRNT_FAN2

PANEL1

SAT

A_R

AID

1

SB_PWR1

DDR DDR_B2 (64 bit,184-pin module)

DDR DDR_A2 (64 bit,184-pin module)

DDR DDR_B1 (64 bit,184-pin module)

DDR DDR_A1 (64 bit,184-pin module)

PCIX2 (64-bit PCI-X)

PCI4 (32-bit 5V PCI)

PCI5 (32-bit 5V PCI)

mP

GA

604

CPU2

AdaptecAIC-8130

PS/2KBMST: MouseB: Keyboard

VG

AC

OM

1

LAN1

LAN2

USB12

SAT

A_R

AID

2S

ATA

_RA

ID3

SAT

A_R

AID

4

SATA2

IntelMCH

E7320

ATIRAGE XL

VGAController

GigabitLAN

BCM5705E

COM2

LPT1

BPSMB1

BMCCONN1AUX_PANEL1

FM_CPU1

CPU_FAN1

FM_CPU2

CPU_FAN2

CLRTC1

8130 LED1

RECOVERY1

HDLED1

USBPW34

USB34

VGA_EN1

LAN_EN2

REAR_FAN2

REAR_FAN1

LAN_EN1

KBPWR1

USBPW12

PSUSMB1

SATA_EN1

CR2032 3VLithium Cell

CMOS Power

BMCSOCKET1

GigabitLAN

BCM5721

NCCH-DR

FLOPPY

8Mbi

tF

lash

BIO

S

SEC_IDE

SuperI/O

IntelICH

6300ESB

PRI_IDE

ATX12V1ATXPWR1

mP

GA

604

CPU2

PCI3 (32-bit, 33MHz 5V)

PCIX1 (64-bit, 66MHz 3V)

26.8cm (10.5in)

30.5

cm (

12in

)

FRNT_FAN1

SATA1

FRNT_FAN2

PANEL1

SAT

A_R

AID

1

SB_PWR1

CR2032 3VLithium Cell

CMOS Power

DDR DIMM_A1 (64 bit,184-pin module)

DDR DIMM_A2 (64 bit,184-pin module)

DDR DIMM_B1 (64 bit,184-pin module)

DDR DIMM_B2 (64 bit,184-pin module)

PCIX2 (64-bit, 66MHz 3V)

PCI4 (32-bit, 33MHz 5V)

PCI5 (32-bit, 33MHz 5V)

mP

GA

604

CPU1

AdaptecAIC-8130

PS/2KBMST: MouseB: Keyboard

VG

AC

OM

1

LAN1

LAN2

USB12

SAT

A_R

AID

2S

ATA

_RA

ID3

SAT

A_R

AID

4

SATA2

IntelMCH

E7210

ATIRAGE XL

VGAController

Intel82547GIGigabitEthernet

Intel82541GIGigabitEthernet

COM2

LPT1BPSMB1

BMCCONN1AUX_PANEL1

FM_CPU1 CPU_FAN1

FM_CPU2

CPU_FAN2

CLRTC1 8130 LED1RECOVERY

HDLED

USBPW34USB34

VGA_EN1

LAN_EN2

REAR_FAN1

REAR_FAN2

LAN_EN1

KBPWR1

USBPW12

PSUSMB1

SATA_EN1

BMCSOCKET1

Page 50: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

A - 6A - 6A - 6A - 6A - 6 Append ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ion

PSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboardPSCH-SR motherboard

PSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboardPSCH-LR motherboard

4Mbi

tF

lash

BIO

S

SEC_IDE1

PANEL1

Intel82541GIGigabitEthernet

Sup

erI/O

adaptecAIC-7901X

USB2.0T: USB1B: USB2

Top:LAN1

PS/2KBMST: MouseB: Keyboard

PRI_IDE1

KBPWR1

REAR_FAN2

REAR_FAN1

LAN_LED1

SB_PWR1

ATXPWR1

PCIX1 (64-bit, 66MHz 3V)

25cm (9.8in)

30.5

cm (

12in

)

LAN2

Socket 478

DDR DIMM_B2 (64 bit,184-pin module)

DDR DIMM_B1 (64 bit,184-pin module)

DDR DIMM_A2 (64 bit,184-pin module)

DDR DIMM_A1 (64 bit,184-pin module)

LAN_EN1LAN_EN2

VGA_EN1

LOCATOR1

J4J5

ATX12V1

CPU_FAN2CPU_FAN1

FRONT_FAN1

FRONT_FAN2

ATIRAGE XL

VGAController

PCI3 (32-bit, 33MHz 5V)

FLOPPY1

SATA1

BM

CS

OC

KE

T1

ZC

RS

KT

1

SATA2

COM2

USB34

FPSMB1

BPSMB1

3568

34 1

SCSIA1

CLRTC1

CHASSIS1

BAT1

PSUSMB1Intel

82547GIGigabitEthernet

PCI2 (32-bit, 33MHz 5V)

SA

SI_

EN

1

J6

BUZZER1

PSCH-SR®

SATA

_RAI

D1SA

TA_R

AID2

SATA

_RAI

D3SA

TA_R

AID4

AdaptecAIC-8110X

CO

M1

VG

AIntel

E7210(Canterwood-ES)

MCH

Intel6300ESB

(Hance-Rapid)ICH

J2

FAN5

PSCH-LR

25cm (9.9in)

31.1

cm (

12.2

in)

BUZZER1

VG

A1

SB_PWR1

BMCSOCKET1CLRTC1

DDR DIMM_A1 (64/72 bit,184-pin module)

DDR DIMM_A2 (64/72 bit,184-pin module)

DDR DIMM_B1 (64/72 bit,184-pin module)

DDR DIMM_B2 (64/72 bit,184-pin module)

IntelCanterwood-ES

MCH

FLO

PP

Y1

PR

I_ID

E1

SE

C_I

DE

1

SuperI/O

So

cke

t 4

78

ATX Power Connector

CR2032 3VLithium Cell

CMOS Power

4MbitFirmware

Hub

SATA2

®

CO

M1

SATA1

FAN6

FAN2

FAN1

FAN3 FAN4

VGA_EN1RECOVERY1

KBPWR1

PS

2_K

B1

PS

2_M

S1

LAN_EN2

LAN_EN1

PCIX1

PCIX2

LAN1

LAN2

USB1

USB2

SW1

LOCLED1

CHASSIS1

J3BPSMB1

Intel82547GI

IntelHance-Rapid

ICH

ATX12V1

MLED1

ATIRAGE-XL

VGAController

PCI1

US

B34

PA

NE

L1

Intel82541GI

Page 51: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE) A - 7A - 7A - 7A - 7A - 7

A.3 Troubleshooting

This troubleshooting guide provides answers to some common problemswhich you may encounter while installing and/or using ASUS ASMB-LE.These problems requires simple troubleshooting that you can perform byyourself. Contact the Wireless LAN Technical Support if you encounterproblems not mentioned in this section.

Prob lemProb lemProb lemProb lemProb lem Solut ionSo lut ionSo lut ionSo lut ionSo lut ion

The loca l/centra l server cannotThe loca l/centra l server cannotThe loca l/centra l server cannotThe loca l/centra l server cannotThe loca l/centra l server cannotconnect to the ASMB-LE board .connect to the ASMB-LE board .connect to the ASMB-LE board .connect to the ASMB-LE board .connect to the ASMB-LE board .

1. Check if the LAN cable isconnected to the LAN port forserver management. See pageA-2 for details.

2. Check if the remote server LANport is working properly. If youhave not previously installed theLAN controller driver, install thesame using the system support CD.

3. Make sure the IP address of boththe remote and local/centralservers are on the same subnet.

4. Set the remote server IP addressand MAC address using the ASUSHost Management ControllerSetup. See Chapter 2 for details.

The ARC cannot rece ive PETThe ARC cannot rece ive PETThe ARC cannot rece ive PETThe ARC cannot rece ive PETThe ARC cannot rece ive PETinformat ion f rom the remoteinformat ion f rom the remoteinformat ion f rom the remoteinformat ion f rom the remoteinformat ion f rom the remotese rve r .se rve r .se rve r .se rve r .se rve r .

Set the remote server PET IP addressand MAC address using the ASUSServer Management Card Utility. SeeChapter 2 for details.

The ASMC ut i l i ty cannot setThe ASMC ut i l i ty cannot setThe ASMC ut i l i ty cannot setThe ASMC ut i l i ty cannot setThe ASMC ut i l i ty cannot setthe BMC MAC address orthe BMC MAC address orthe BMC MAC address orthe BMC MAC address orthe BMC MAC address orcannot enab le TCO.cannot enab le TCO.cannot enab le TCO.cannot enab le TCO.cannot enab le TCO.

Copy the n i c . i n in i c . i n in i c . i n in i c . i n in i c . i n i file to the ASMCdirectory, then try again. The n i c . i n in i c . i n in i c . i n in i c . i n in i c . i n ifile is available from the support CD.

Page 52: Server Management Boarddlsvr04.asus.com/pub/ASUS/server/ASMB/ASMB-LE/e... · qualified service technician or your retailer. Operation safety • Before installing any component to

A - 8A - 8A - 8A - 8A - 8 Append ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ionAppend ix : Reference in format ion