99625pon eps

BUTTON AT CONVEYOR INLET

BUTTON AT CONVEYOR OUTLET

PROCECO • DESCRIPTION BULLETIN

99625-VG1

SERIAL NO. 99-625 CONTROL PANEL

1 - OPERATOR INTERFACE

2 - "MESSAGE" INDICATING LIGHT (AMBER)

3 - "SYSTEM START" ILLUMINATING PUSHBUTTON (GREEN)

4 - "EMERGENCY STOP" MUSHROOM PUSH-PULL BUTTON (RED)

5 - CONVEYOR BELT SPEED POTENTIOMETER

6 - MAIN DISCONNECT SWITCH

7 - "CYCLE STOP" PUSHBUTTON (RED)

8 - "CYCLE START" PUSHBUTTON (BLACK)

9 - TEMPERATURE CONTROLLER FOR SECOND STAGE SOLUTION

10- TEMPERATURE CONTROLLER FOR FIRST STAGE SOLUTION

11- "CONVEYOR STOP" MUSHROOM PUSH-PULL BUTTON (YELLOW)

0002

PAGE 1 OF 1

Page 2: SERIAL NO. 99 625 CONTROL PANEL - fobinc.com · SERIAL NO. 99-625 CONTROL PANEL 1 ... FIRST ANGLE c: PROJECTION SCALE NONE SHEET 1 OF ... or in part— to third parties without the

FRESH WATER

DRAIN

SOLUTION

REGENERATIVE BLOWER

BOO SCFM 0 70 W.C.

10 1101316

AIR KNIFE

UNLOADING

I3rd STAGE — BLOW OFF

CO.NUP4014— ORME

O

I 2nd STAGE — RINCE TANK I

BV2

GAS BURNER 200 000BTU 0 7- 14 W.0

DATE NI1/00/01 APPROBATION ENG

MLE : FLUID SCHEMATIC DRAWN BY : M.H. I IdAn.; 12/16/99 I VERIFIED BY :

APP. ENG. :

146:,

DATE REF.: 98399H01 REV.: 000

MODEL : MODULAR BELT CONVEYOR WASHER

FIRST ANGLE c: PROJECTION

SCALE

NONE SHEET

1 OF

REVISION

000 DRAWING No .

99625H01

REV. BY DESCRIPTION

Page 3: SERIAL NO. 99 625 CONTROL PANEL - fobinc.com · SERIAL NO. 99-625 CONTROL PANEL 1 ... FIRST ANGLE c: PROJECTION SCALE NONE SHEET 1 OF ... or in part— to third parties without the

PG PG5

T FCYI

LOADING

IM1

SL

AIR EXHAUST TO CUSTOMER

FACILITY 800 SOFIA 0 1 " W.C.

EXHAUST BLOWER

WATER SUPPLY 35 USgpm 0 40 psi

Fo

V

57R1

PC

SK1

I 1st STAGE — WASH TANK

BV1 GAS BURNER

200 000BTU 0 7—I4 W.0

S

HIGH MAKE—UP LEVEL

LOW MAKE—UP LEVEL ALARM LOW LEVEL

OIL DRUM (BY CUSTOMER)

M4

MOTORS AND PUMPS LIMIT SWITCHES AIR

I REGENERATIVE BLOWER FILTER ELEMENT

ELECTRIC MISCELLANEOUS

FIRST STAGE PUMP MOTOR

SECOND STAGE PUMP MOTOR

REGENERATIVE BLOWER MOTOR

EXHAUST BLOWER MOTOR

CONVEYOR MOTOR

FIRST STAGE GAS BURNER MOTOR

SECOND STAGE GAS BURNER MOTOR

OIL SKIMMER MOTOR

FIRST STAGE PUMP

SECOND STAGE PUMP

REGENERATIVE BLOWER

SWITCHES FLOAT

FEST STAGE ACCES DOOR

SECOND STAGE ACCES DOOR

FIRST STAGE BAG FILTER COVER

VALVES SOLENOID

MI LS1 FE2 M2 LS2

M3 LS3 M4

FIRST STAGE SOLUTION TEMPERTURE CONTROL

SECOND STAGE SOLUTION TEMPERTURE CONTROL

SOLUTION AND WATER MISCELLANEOUS

M5 TC1 M6 TC2 M7

FIRST STAGE WATER MAKE—UP

SECOND STAGE WATER MAKE—UP

MANUAL VALVES

MB S1 P1 S2

OIL SKIMMER

FIRST STAGE PUMP PRESSURE GAGE

FIRST STAGE BAG FILTER PRESSURE GAGE

FIRST STAGE FLOW CONTROL PRESSURE GAGE

SECOND STAGE FLOW CONTROL VALVE PRESSURE GAGE

FIRST STAGE WATER INLET STRAINER

SECOND STAGE WATER INLET STRAINER

FIRST STAGE BAG FILTER

P2 SKI P3 PG1

PG2

FIRST STAGE SOLUTION DRAIN

SECOND STAGE SOLUTION DRAIN

FIRST STAGE FLOW CONTRO VALVE

SECOND STAGE FLOW CONTROL VALVE

By1 PG3

FIRST STAGE SOLUTION LOW LEVEL

SECOND STAGE SOLUTION LOW LEVEL

FIRST STAGE SOLUTION MAKE—UP

SECOND STAGE SOLUTION MAKE—UP

FS1 BV2 PC4

FS2 FCV1 STR1

FS3 FCV2 S1R2

FS4 FE1

Page 4: SERIAL NO. 99 625 CONTROL PANEL - fobinc.com · SERIAL NO. 99-625 CONTROL PANEL 1 ... FIRST ANGLE c: PROJECTION SCALE NONE SHEET 1 OF ... or in part— to third parties without the

44' 21' UNLOADING OW-OFF

L

CONVEYOR DRIVE

DRAWING No. RBISION

001 SHEET SCALE

N.T.S. 99625A01

CUSTOMER APPROVAL FOR CONSTRUCTION

CUSTOMER : ESTON MANUFACTURING YOUR INQUIRY/P.O. : E-14439 OUR OUOTATION No. : 4419R2 OUR PROJECT No. ,: 99-625

WITHOUT ANY CHANGES ❑ WITH MODIFICATIONS MARKED ON THIS BLUEPRINT ❑

THIS MACHINE WILL BE BUILT AS PER PROCECO SPECIFICATIONS UNLESS OTHERWISE INDICATED. CUSTOMER SPECIFICATIONS INCLUDED ON THIS ORDER : NONE ...._

....—.—.—......

_ DAY__ . MONTH YEAR ..... .... NAIVE (PRINT): TITLE: SIGNATURE:

This design is property of PROCECO LTD.

It must not be made available — in whole

or in part— to third parties without the

authorization of PROCECO LTD. or used in

any way to the disadvantage of PROCECO LTD.

SHIPPING DIMENSIONS ONNECTIONS - LENGTH : 2C-0"

- WIDTH : 8 . -0"

- HEIGHT :

- APPROXIMATE WEIGHT : 6500 LOS

12/09/99 SL 00 1 ADD 1 - 1/2" TO LOADING HEIGHT NOTE : ALL LIQUID MEASURES IN U.S. GALLONS

AND DIMENSIONS IN INCHES /PPROBADON ENG REV. BY OESCRPTIO DATE 0./11,1

TILE : APPROVAL DRAWN BY : NT I 2%,.,.; 11/29/99 I wimp BY :

REF. REV.: 000 I APP. ENG. :

ucoa MBCW 24X16-G-4 -2R-BO-SS

FIRST ANGLE r-- PROJECTION '

24* BELT WIDTH

GAZ EXHAUST REMOVABLE FOR

SHIPPING

16" CLEARANCE

HEIGHT

43"

r 0-

REGENERATIVE BLOWER C/W SOUND ENCLOSURE VIEW C

AIR KNIVES CONFIGURATION

SECTION D-D IRICAL CABINET C/W INNECT SWITCH & BREAKER

rCH

VAC, 3 PHASES, iz, 39 Amp. iNECTION : 1 X 1/2" NPT

x 2" NPTM

: 800 SCFM 0 1"SP

)UCT : 3 1/2" x 4" : 2 x 1-1/2" NPTM

;AS , 400 CFH !ED : 7-14" W.C.

2 x 1/2" NPT

2 x 4" PIPE

ES MUST BE :CCORDINGLY.

u. NOTICE II"

PUMP PERFORMANCE IS MEASURED AT RI VF

SPECIFIC GRAVITY I.0% AT SEA LEVEL

AIR KNIVES CONFIGURATION- 1 ON TOP, 1 ON BUTTON

/3 ON EACH SIDE or CONVEYOR BELT.

E-STOP

Page 5: SERIAL NO. 99 625 CONTROL PANEL - fobinc.com · SERIAL NO. 99-625 CONTROL PANEL 1 ... FIRST ANGLE c: PROJECTION SCALE NONE SHEET 1 OF ... or in part— to third parties without the

20' 0*

24" TRANSFER VESTIBULE

21' TRANSFER VESTIBULE

21" ENTRANCE VESTIBULE

(i)

C

OVERFLOW & OIL SKIMMER

DRAIN

40- /2' LOADING HEIGHT

GAS BURNER

B

EXHAUST BLOWER r's

11,L_ a I II r

[:11L1:_r_ 111..

B' 0'

1st STAGE

4, PUMP VIEW B A

2nd STAGE PUMP

LEVEL CONTROL FLO

now CONTROL VALVE

CONVEYOR STOP

HINGED ACCESS DOOR BELT OIL SKIMMER

SINGLE BAG ALTER 100 MICRON

FLOW CONTROL VALVE

SPECIFICATIONS

ADDITIONNAL FEATURES - AUTOMATIC BELT TYPE OIL SKIMMER

C/W 7 DAY TIMER - AUTOMATIC SOLUTION LEVEL CONTROL (BOTH STAGES) - PROOF TESTING AT PROCECO (1 DAY) - 55304 TANK AND CANOPY ONLY - DIGITAL TEMPERATURE CONTROL - INDEXING CONVEYOR - PLC A.B. - CSA CERTIFICATION - OSHA CERTIFICATION - PHOTO EYES ON LOADING & UNLOADING

GENERAL - WORKPIECES : RDM HOUSING

- CONVEYOR DRIVE : 1/4HP - CONVEYOR SPEED : 0.503 FPM

- EXHAUST BLOWER : 1 HP

FIRST STAGE - WASH - TANK CAPACITY : 300 USgol. - PUMP CAPACITY : 160 USGPM 0 35 PSI

- PUMP MOTOR : 7.5 HP 0 3600 RPM, TEFC

- GAS HEATING : 200000 BTU/HR

- OPERATION TEMPERATURE : 140T

SECOND STAGE - RINSE - TANK CAPACITY : 200 USgal. - PUMP CAPACITY : 115 USGPM 0 35 PSI

- PUMP MOTOR : 5 HP 0 3600 RPM, TEFC

- GAS HEATING : 200000 BTU/HR

- OPERATION TEMPERATURE : 140T

THIRD STAGE - BLOW-OFF - BLOWER CAPACITY : 800 SCFM 0 70" WC

- BLOWER MOTOR : 25 HP 0 3600 RPM, TEFC

SERVICI 0 - ELECTRIC :

- FRESH WATT

- TANK DRAIN

- EXHAUST 81

DIM. OF Ell QS - TANK OVER!

• FPUREELssu: RNAETI

INLET CONK ® - BURNER EX