55
SECTION 3 DESIGN OF POSTTENSIONED COMPONENTS FOR FLEXURE DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: TREY HAMILTON, UNIVERSITY OF FLORIDA

SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

SECTION 3

DESIGN OF POST‐TENSIONED COMPONENTS 

FOR FLEXURE

DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEELEAD AUTHOR: TREY HAMILTON, UNIVERSITY OF FLORIDA

Page 2: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

NOTE: MOMENT DIAGRAM CONVENTION

• In PT design, it is preferable to draw moment diagrams to the tensile face of the concrete section.  The tensile face indicates what portion of the beam requires reinforcing for strength.   

• When moment is drawn on the tension side, the diagram matches the general drape of the tendons.  The tendons change their vertical location in the beam to follow the tensile moment diagram.  Strands are at the top of the beam over the support and near the bottom at mid span.

• For convenience, the following slides contain moment diagrams drawn on both the tensile and compressive face, denoted by (T) and (C), in the lower left hand corner.  Please delete the slides to suit the presenter's convention.  

Page 3: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

OBJECTIVE 1 hour presentation Flexure design considerations

Page 4: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

PRESTRESSED GIRDER BEHAVIOR

k1DL

Lin and Burns, Design of Prestressed Concrete Structures, 3rd Ed., 1981

1.2DL + 1.6LL

DL

Page 5: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

LIMIT STATES – AND PRESENTATION OUTLINE

Load Balancing – k1DL  Minimal deflection.

Select k1 to balance majority of sustained load.

Service – DL + LL Concrete cracking.  

Check tension and compressive stresses.

Strength – 1.2DL + 1.6LL +1.0Secondary Ultimate strength.

Check Design Flexural Strength (Mn)

Page 6: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

EXAMPLE

Load Balancing > Service Stresses > Design Moment Strength

Page 7: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

DIMENSIONS AND PROPERTIES

Page 8: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

SECTION PROPERTIES

Page 9: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

LOAD BALANCING Tendons apply external self‐equilibrating transverse loads to member.

Forces applied through anchorages The angular change in tendon profile causes a transverse force on the member

Load Balancing > Service Stresses > Design Moment Strength

Page 10: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

LOAD BALANCING Transverse forces from tendon “balances” structural dead loads.

Moments caused by the equivalent loads are equal to internal moments caused by prestressing force

Load Balancing > Service Stresses > Design Moment Strength

Page 11: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

EQUIVALENT LOAD

Harped Tendon can be sized and placed such that the upward force exerted by the tendon at midspan exactly balances the

applied concentrated loadLoad Balancing > Service Stresses > Design Moment Strength

Page 12: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

EQUIVALENT LOAD

Parabolic Tendon can be sized and placed such that the upward force exerted by the tendon along the length of the member exactly

balances the applied uniformly distributed load

Load Balancing > Service Stresses > Design Moment Strength

Page 13: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

FORMULAS (FROM PTI DESIGN MANUAL?)

Load Balancing > Service Stresses > Design Moment Strength

Page 14: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

EXAMPLE – LOAD BALANCING

Determine portion of total dead load balanced by prestressing

wDL = 0.20 klfsuperimposed dead load (10psf*20ft)

wsw = 2.06 klfself weight including tributary width of slab

Load Balancing > Service Stresses > Design Moment Strength

Page 15: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

EXAMPLE – LOAD BALANCING

Including all short and long term losses

Load Balancing > Service Stresses > Design Moment Strength

Page 16: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

EXAMPLE – LOAD BALANCING

Prestressing in this example balances ~100% of total dead load.

In general, balance 65 to 100% of the self‐weight Balancing in this range does not guarantee that service or strength limit states will be met.  These must be checked separately

Load Balancing > Service Stresses > Design Moment Strength

Page 17: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

STRESSES Section remains uncracked Stress‐strain relationship is linear for both concrete and steel

Use superposition to sum stress effect of each load.  Prestressing is just another load.

Load Balancing > Service Stresses > Design Moment Strength

Page 18: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

CALCULATING STRESSES

Load Balancing > Service Stresses > Design Moment Strength

Page 19: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

STRESSES Stresses are typically checked at significant stages

The number of stages varies with the complexity and type of prestressing. 

Stresses are usually calculated for the service level loads imposed (i.e. load factors are equal to 1.0). This includes the forces imposed by the prestressing.

Load Balancing > Service Stresses > Design Moment Strength

Page 20: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

PLAIN CONCRETE

Load Balancing > Service Stresses > Design Moment Strength(T)

Page 21: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

PLAIN CONCRETE

Load Balancing > Service Stresses > Design Moment Strength(C)

Page 22: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

CONCENTRIC PRESTRESSING

Load Balancing > Service Stresses > Design Moment Strength(T)

Page 23: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

CONCENTRIC PRESTRESSING

Load Balancing > Service Stresses > Design Moment Strength(C)

Page 24: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

ECCENTRIC PRESTRESSING

Load Balancing > Service Stresses > Design Moment Strength(T)

Page 25: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

ECCENTRIC PRESTRESSING

Load Balancing > Service Stresses > Design Moment Strength(C)

Page 26: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

ECCENTRIC PRESTRESSINGSTRESSES AT SUPPORT

Load Balancing > Service Stresses > Design Moment Strength(T)

Page 27: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

ECCENTRIC PRESTRESSINGSTRESSES AT SUPPORT

Load Balancing > Service Stresses > Design Moment Strength(C)

Page 28: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

VARY TENDON ECCENTRICITY

Harped Tendon follows moment diagram from concentrated load

Parabolic Drape follows moment diagram from uniformly distributed load

Load Balancing > Service Stresses > Design Moment Strength(T)

Page 29: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

VARY TENDON ECCENTRICITY

Harped Tendon follows moment diagram from concentrated load

Parabolic Drape follows moment diagram from uniformly distributed load

Load Balancing > Service Stresses > Design Moment Strength(C)

Page 30: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

STRESSES AT TRANSFER ‐MIDSPAN

Including friction and elastic losses

Load Balancing > Service Stresses > Design Moment Strength

Page 31: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

STRESSES AT TRANSFER –FULL LENGTH

Stress in top fiberStress in bottom fiber

Load Balancing > Service Stresses > Design Moment Strength

Page 32: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

STRESSES AT SERVICE ‐MIDSPANIncluding all short and long term losses

Load Balancing > Service Stresses > Design Moment Strength

Page 33: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

STRESSES AT SERVICE – FULL LENGTH

Stress in top fiberStress in bottom fiberTransition (7.5 root f’c)Cracked (12 root f’c)

Load Balancing > Service Stresses > Design Moment Strength

Page 34: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

FLEXURAL STRENGTH (MN)ACI 318 indicates that the design moment strength of flexural members are to be computed by the strength design procedure used for reinforced concrete with fps is substituted for fy

Load Balancing > Service Stresses > Design Moment Strength

Page 35: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

ASSUMPTIONS Concrete strain capacity = 0.003 Tension concrete ignored Equivalent stress block for concrete compression Strain diagram linear Mild steel: elastic perfectly plastic Prestressing steel: strain compatibility, or empirical Perfect bond (for bonded tendons)

Load Balancing > Service Stresses > Design Moment Strength

Page 36: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

fps ‐ STRESS IN PRESTRESSING STEEL AT NOMINAL FLEXURAL STRENGTH Empirical (bonded and unbonded tendons) Strain compatibility (bonded only)

Load Balancing > Service Stresses > Design Moment Strength

Page 37: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

EMPIRICAL – BONDED TENDONS

270 ksi prestressing strand

Load Balancing > Service Stresses > Design Moment Strength

Page 38: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

EMPIRICAL – BONDED TENDONSNO MILD STEEL

Load Balancing > Service Stresses > Design Moment Strength

Page 39: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

BONDED VS. UNBONDED SYSTEMS

•Steel-Concrete force transfer is uniform along the length

•Assume steel strain = concrete strain (i.e. strain compatibility)

•Cracks restrained locally by steel bonded to adjacent concrete

Load Balancing > Service Stresses > Design Moment Strength

Page 40: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

BONDED VS UNBONDED SYSTEMS

•Steel-Concrete force transfer occurs at anchor locations

•Strain compatibility cannot be assumed at all sections

•Cracks restrained globally by steel strain over the entire tendon length

•If sufficient mild reinforcement is not provided, large cracks are possible

Load Balancing > Service Stresses > Design Moment Strength

Page 41: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

SPAN‐TO‐DEPTH 35 OR LESS

SPAN‐TO‐DEPTH > 35

Careful with units for fse (psi)

Load Balancing > Service Stresses > Design Moment Strength

Page 42: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

COMBINED PRESTRESSING AND MILD STEEL

Assume mild steel stress = fy Both tension forces contribute to Mn

Load Balancing > Service Stresses > Design Moment Strength

Page 43: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

STRENGTH REDUCTION FACTOR 

Applied to nominal moment strength (Mn) to obtain design strength (Mn) 

ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

Section is defined as compression controlled, transition, or tension controlled  

Load Balancing > Service Stresses > Design Moment Strength

Page 44: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

STRENGTH REDUCTION FACTOR 

Load Balancing > Service Stresses > Design Moment Strength

Page 45: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

DETERMINE FLEXURAL STRENGTH

Is effective prestress sufficient? Determine fps Use equilibrium to determine: Depth of stress block a Nominal moment strength Mn

Determine depth of neutral axis and strain in outside layer of steel (et)

Determine  Compute Mn

Load Balancing > Service Stresses > Design Moment Strength

Page 46: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

fps OF BONDED TENDON

Load Balancing > Service Stresses > Design Moment Strength

Page 47: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

a and 

Load Balancing > Service Stresses > Design Moment Strength

Page 48: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

MN – BONDED TENDON

Load Balancing > Service Stresses > Design Moment Strength

Page 49: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

REINFORCEMENT LIMITS  Members containing bonded tendons must have sufficient flexural strength to avoid abrupt failure that might be precipitated by cracking.

Members with unbonded tendons are not required to satisfy this provision.

Load Balancing > Service Stresses > Design Moment Strength

Page 50: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

REINFORCEMENT LIMITS 

Load Balancing > Service Stresses > Design Moment Strength

Page 51: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

fps – UNBONDED TENDON

Load Balancing > Service Stresses > Design Moment Strength

Page 52: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

Mn – UNBONDED TENDON

Load Balancing > Service Stresses > Design Moment Strength

Page 53: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

MIN. BONDED REINF. Members with unbonded tendons must have a minimum area of bonded reinf.

Must be placed as close to the tension face (precompressed tensile zone) as possible.

As = 0.004 Act

Act – area of section in tension

Load Balancing > Service Stresses > Design Moment Strength

Page 54: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

AS MINIMUM

Load Balancing > Service Stresses > Design Moment Strength

Page 55: SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR … · obtain design strength ( M n) ranges from 0.6 to 0.9 Determined from strain in extreme tension steel (mild or prestressing)

Mn – UNBONDED TENDONINCORPORATE MILD STEEL

Load Balancing > Service Stresses > Design Moment Strength