Seamless Connectivity
from IT to Sensor
Dr. Karsten Walther
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 1
Founded 10/2018
BackgroundIIoT
VisionSeamless
Connectivity
MissionElectronics for
Sensors
17 + 3Employees
SOP2020
Perinet GmbHIntroduction
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 2
LTE
Technican
Internet
Central Cabinet I Technical Room
Sensor 2 ITTypical Setup
Edge Computer
Ethernet
Sing
le P
air E
ther
net
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 3
Shift Process Owner from Automation to Operations and/or IT
Management Tasks in Focus
Cascade of Intelligence
Sensor Level
Edge Computing
Cloud
User App
Single Pair Ethernet used on the last segment to sensors/actuators
Allows seamless communication with IT
Real End 2 End semantics e.g. for security
Sensor 2 ITUnderstand the Scene
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 4
OT/ITAT
$
The Arenais changing
Today‘s Top Dog
Future Cash Cow- Data ConsumingServices creates
Added Value
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 5
raw data
AT Environment
Data Analyst Operations
Low Level Interfaces
Value PropositionUser Pain Points
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 6
superfood data
Value PropositionGains
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 7
Sensor / Actuator
Global/Local Cloud
Router
Operator
MICA
IP basedCommunication
Why networked access is that important Seamless Communication
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 8
Just an impressionWhat you see when accessing the SPE sensor with a browser
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 9
Just an impressionWhat you see when accessing the SPE sensor with a browser
If a browser can consume it –ANY IT application can consume it easily
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 10
1. I
nst
alla
tio
n Physical Connection
Infrastructure approach, just use network ports
Topology as required
NetworkedSensors/Actuators
Data Hub (typically)
Cloud Connector (typically)
Dashboard for local user(optional)
2. A
ssig
nm
ent Tell the sensor where it
is installed
Web based interface
Type of Sensor if needed
3. N
etw
ork
ing Digital Connection
Find Peers by Name (self-x)
Setup secure connection
Refine setup (optional) 4. O
per
atio
n Communication
Data gathering andconversion
Value Preprocessing in the sensor (optional)
Transmission to higherlevel IT system (cloud), potentially event based
manually automatic
Setup Sequence4 Steps
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 11
Setup Sequence4 Steps
Benefit is in Provisioning and
Planning
No mapping between domains
Process image, field bus 2 IT data point
Self-X capabilities
Your Computer finds the network
printer for years. Why do you configure
sensor bus addresses?
Process In-Place
Data Conversion in sensor, not
remotely on Head Unit
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 12
Setup Sequence4 Steps
Benefit is in Provisioning and
Planning
No mapping between domains
Process image, field bus 2 IT data point
Self-X capabilities
Your Computer finds the network
printer since years. Why you configure
sensor bus addresses?
Process In-Place
Data Conversion in sensor not remotely
on Head Unit
Seamless is just easier –it will reduce the efforts for the IT centric user
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 13
SPE is not just a new cabling, it allows to interact with
sensors/actuators in a totally different way then before.
Sensors/Actuators are now first class citizens in the IT-
network, able to interact in an intelligent manner.
Single Pair Ethernet is the keySeamless Communication
Seamless Sensor2IT Perinet GmbH, Rudower Chaussee 29, 12489 Berlin | Telefon: +49 30 86 32 06 700 | [email protected] | www.perinet.io 14
Where to Startwith an evaluation kit
Media Converter & Power Supply
3-Port Switch
Adapter (0…10V)
e.g. 3rd Party Distance Sensor
T1 Hybrid Cable
Adapter (GPIO)
Module for directintegration intosensors/actuators
Perinet GmbHRudower Chaussee 2912489 Berlin
+49 30 86 32 06 700