Features
Surface Omega-type seal
Movement High movement capacity ASTM E-1399 Class I: Thermal Class II: Wind Class III: Seismic
Omegatec 1300 : A01
SEAL EXPANSION JOINT Concrete to Concrete | Steel to Steel
50 - 250 mm ( 2 - 10” ) Expansion Gaps
System Options
Gap width(s) 50, 80, 100, 140, 200, 250 mm Height(s) 13, 18 mmMetal type(s) Galvanised Steel clamping systemColour(s) BlackFire barrier 120-240 minutesWaterproofing Max.waterpressure1.75MPaPre-assemblyinfactory ContactVexcolt
Traffic Frequency per day
- - - - -
www.vexcolt.com
APPLICATIONS
Immersed Tunnels
Bored Tunnels
Aqueducts
Roads & Bridges
Submersed Structures
VEXCOLT | United Kingdom | T : +44 (0) 1752 894133 | E : [email protected] | W : www.vexcolt.com
VEXCOLT | United Kingdom | T : +44 (0) 1752 894133 | E : [email protected] | W : www.vexcolt.com
Omegatec 1300 : A01
SEAL EXPANSION JOINTConcrete to Concrete | Steel to Steel
50 - 250 mm ( 2 - 10” ) Expansion Gaps
Joint Gap Movement Water Pressure Product Dimensions Product
Location Width Capacity (mm) Seal Fully Open Seal Fully Closed Height Stud Fixing Radius Width Number
B (mm) ± [Total] Mpa Mpa H1 (mm) (mm) A (mm) C (mm)
Concrete-Concrete Steel - Steel
50 +40/-30 [70]0.75 1.75
13M24
25 210 1300-A01-050
80 +60/-40 [100] 40 240 1300-A01-080
100 +70/-50 [120]0.50 1.20
50 260 1300-A01-100
140 ± 70 [140] 70 300 1300-A01-140
200 ± 90 [180] 0.30 0.80M30
100 360 1300-A01-200
250 ± 100 [200] 0.25 0.75 18 120 410 1300-A01-250
Expansion Joint Selection Criteria Load Rating Product Details
20
0.20
0.00
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00
30 40 50 60 70 90
GAP WIDTH (mm)
NominalGap Width
NominalGap Width
WA
TER
PR
ESSU
RE
(Mp
a)
80 40
0.20
0.00
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00
50 60 70 80 90 110 120 130 140
GAP WIDTH (mm)
WA
TER
PR
ESSU
RE
(Mp
a)
100 50
0.20
0.00
0.40
0.60
0.80
1.00
1.20
1.40
60 70 80 90 100 120 130 140 150 160 170
GAP WIDTH (mm)
WA
TER
PR
ESSU
RE
(Mp
a)
110
70
0.00
80 90 100 110 120 140 150 160 170 180 190 200 210
GAP WIDTH (mm)
WA
TER
PR
ESSU
RE
(Mp
a)
130 110
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0.00
120 130 140 150 160 180 190 200 210 220 230 240 250 260 270 280 290
GAP WIDTH (mm)
WA
TER
PR
ESSU
RE
(Mp
a)
170 150 160 170 180 190 200 220 230 240 250 260 270 280 290 300 310 320 330 340 340
GAP WIDTH (mm)W
ATE
R P
RES
SUR
E (M
pa)
210
0.20
0.40
0.60
0.80
1.00
1.20
1.40
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0.00
NominalGap Width
NominalGap Width
Min.Gap Width
Min.Gap Width
Min.Gap Width
Min.Gap Width
Max.Gap Width
Min.Gap Width
Min.Gap Width
Max.Gap Width
Max.Gap Width
Max.Gap Width
Max.Gap Width
Max.Gap Width
NominalGap Width
NominalGap Width
SEAL EXPANSION JOINTConcrete to Concrete | Steel to Steel
50 - 250 mm ( 2 - 10” ) Expansion Gaps
Omegatec 1300 : A01-050 Omegatec 1300 : A01-080 Omegatec 1300 : A01-100
Omegatec 1300 : A01
Water Pressure Capacity vs Seal Movement Range
All Omegatec 1300 : A01sealsareformedwiththreelayersofnylonreinforcementasstandard. TheminimumwaterpressureFactorofSafetyis3.0.
VEXCOLT | United Kingdom | T : +44 (0) 1752 894133 | E : [email protected] | W : www.vexcolt.com
20
0.20
0.00
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00
30 40 50 60 70 90
GAP WIDTH (mm)
NominalGap Width
NominalGap Width
WA
TER
PR
ESSU
RE
(Mp
a)
80 40
0.20
0.00
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00
50 60 70 80 90 110 120 130 140
GAP WIDTH (mm)
WA
TER
PR
ESSU
RE
(Mp
a)
100 50
0.20
0.00
0.40
0.60
0.80
1.00
1.20
1.40
60 70 80 90 100 120 130 140 150 160 170
GAP WIDTH (mm)
WA
TER
PR
ESSU
RE
(Mp
a)
110
70
0.00
80 90 100 110 120 140 150 160 170 180 190 200 210
GAP WIDTH (mm)
WA
TER
PR
ESSU
RE
(Mp
a)
130 110
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0.00
120 130 140 150 160 180 190 200 210 220 230 240 250 260 270 280 290
GAP WIDTH (mm)
WA
TER
PR
ESSU
RE
(Mp
a)
170 150 160 170 180 190 200 220 230 240 250 260 270 280 290 300 310 320 330 340 340
GAP WIDTH (mm)
WA
TER
PR
ESSU
RE
(Mp
a)
210
0.20
0.40
0.60
0.80
1.00
1.20
1.40
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0.00
NominalGap Width
NominalGap Width
Min.Gap Width
Min.Gap Width
Min.Gap Width
Min.Gap Width
Max.Gap Width
Min.Gap Width
Min.Gap Width
Max.Gap Width
Max.Gap Width
Max.Gap Width
Max.Gap Width
Max.Gap Width
NominalGap Width
NominalGap Width
Omegatec 1300 : A01
SEAL EXPANSION JOINT Concrete to Concrete | Steel to Steel
50 - 250 mm ( 2 - 10” ) Expansion Gaps
Omegatec 1300 : A01-140 Omegatec 1300 : A01-200 Omegatec 1300 : A01-250
VEXCOLT | United Kingdom | T : +44 (0) 1752 894133 | E : [email protected] | W : www.vexcolt.com