Upload
akanksha-anil
View
32
Download
2
Tags:
Embed Size (px)
DESCRIPTION
ZTE 8890 commitioning
Citation preview
Commissioning Of SDR BTS
8800 & 8900
1) Turn OFF WINDOWS FIREWALL2) Turn OFF ANTIVIRUS
• If you wish to logging in the CC1 (Bottom)Set LAPTOP IP :192.254.1.18 (For CC1)Subnet Mask :255.255.255.0 (For CC1)
If you wish to logging in the CC2 (Upper) Set LAPTOP IP : 192.254.2.18 ( For CC2)Subnet Mask :255.255.255.0 ( For CC2)
If you are logging in the CC1 (Bottom)Set IP(LMT) :192.254.1.16 (For CC1)
Logging into CC2 (Upper)Set IP(LMT): 192.254.2.16 ( For CC2)
After Set IP in Local Area Connection,connect LAN cable to CC
card in ETH 1 port. After connecting cable you just check LED status at
extreme leftside of card in which eth1 is continuously blinking.
Go to LMT Software ,click on LMT START
Select Version :4.00.210eP01(Use DEFAULT Version)
Select Station:For CC1 :192.254.1.16
CC2: 192.254.2.16
click on online configuration >>> RUN Version
For 8800: As you select model 8800 it shows rack now you need to create card ( if cards not
created )
Create Card In respective slot
Create Card :Right Click on slotthen add board
select boardok
commissioning procedure is same for all BTS Right Click on Base Station
Click on Configure basic attribution
Node B Id: Put Site ID
SNTP Server Address : 139. BSC No. .1 .200
Transmission Mode : Select IP
Radio Mode : Select GSM
GSM Station No. : Site IDE1/T1 Medium : E1
Time Zone : Select GMT +5:30
Click On E1/T1 Link : Right Click And Add Link ID : Select 0 (here no need to use 1,2,3)
Link Type: Select BSC
For HDLC Parameter : Right Click and add
Click On PPP Parameter :Right Click and add and
PPP encapsulation : Select ML-PPP
HDLC Link Id: Select Link 0 Base Station IP: Put Base Station IP
(118.BSC ID. HDLC No. 200 )
Click On Global Parameter :Right Click and add
Working Mode : Change to IP Over PPP
Click On IP parameter : Right Click and Add and OK
SCTP Parameter Management :Right click and add Local Port ID : It should be site id
Remote port ID :14592+Module no.Remote IP address: RPU IP ( 118. BSC ID. 1. 1 )
Click On OMC-B parameter: Right Click and add Operation and maintenace Gateway ip: Put RPU
IP ( 118. BSC ID. 1. 1 )
For Export Config file