12
IDES CANADA INC. SCENTROiD SM100 FUTURE OF SENSORY TECHNOLOGY

SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

Embed Size (px)

Citation preview

Page 1: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

IDES CANADA INC.

SCENTROiDSM100

FUTURE OF SENSORY TECHNOLOGY

Page 2: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

SCENTROiD

HIGHER STANDARDS

accurately quantify ambient odour strength. This revolutionary device

guessing at odour strength or using expensive odour measuring laboratories.

Page 3: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

3

Every situation is unique and every client’s requirement is di�erent. At IDES we strive to build a lasting association through close communication, and personal relationships.

SCENTROID

ACHIEVEMENTS

5 32 CountriesIDES CANADA has the largest growth of salesin the industry ... in the world!Years

. Canada

. USA

. Brazil

. Peru

. Mexico

. Chile

. Colombia

. UK

. France

. Ireland

. Italy

. Norway

. Spain

. Finland

. Germany

. Austria

. Sweden

. Ukraine

. Denmark

. Russia

. Latvia

. Turkey

. Belgium

. Netherlands

. Kenya

. South Africa

. China

. South Korea

. Malaysia

. Hong Kong

. Slovakia

. Australia

Page 4: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

27 métropolesOlfactoExpert inc. et IDES CANADA ont le taux d’accélération des ventes le plus important du marché de toute l’industrie ... dans le monde. a n s

SCENTROID

ra n ve ru t r ra r k. O ra valv c n r r t nt air

SM100

4

FEATURES IDES CANADA has the largest growth of salesin the industry ... in the world!

The SM100 draws a sample of ambient air via venture pump and dilutes it using fresh odourless air from a compressed air tank. Operator uses an adjustable sliding valve to control the ratio of fresh to ambient air.

Accurate- Comparable results to full scale odour labratories

Rather fresh odourless air is supplied by a portable light weight high-pressure air tank. This leads to the highest level of accuracy in the industry.

Wide Detection ThresholdMeasure odours from as low as 2 OU all the way to 30,000 OU with 60 steps in between.

Zero MaintenanceRequires no other accessories such as sample bags

No pumps or other moving parts to maintainDoes not require frequent re-calibration

Unparalleled Reliability SM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to last!

Cost E�ective

Page 5: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

Main technical points of the olfactometer SM100 customized to your needs

TECHNICAL SPECS

Manufacture IDES CANADA INC.IDES CANADA INC.

OLFACTO EXPERT INC.

Model

Air Supply Capacity

# of samples per tank

Dilution range

Dilution Principle

# of Dilution Steps:

Dilution Steps:

Selectable Ranges

Pres. Flow Rate:(l/min)

Presentation Face

Face Mask

Wetted Material

Tank material

Dimensions (in)

Weight Kg/(lb)

SCENTROID - SM100

15 min

10-15

2 – 30,000 (2 )

Stainless Steel Eductor

15 (adjustable range)

Variable

2-101; 4-678; 44-656; 2-3600; 2000-30,000

20

0.3 Velocity (m/s)

Carbon Fibre

16x6x6

3.5 (8)

SCENTROID

5

Stainless Steel and PTFE

15

Page 6: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

SCENTROID

Case

SM100

ODMAP

Diluting Sampler N-BKIT

6

Mask

Tank

SM100 Accessories and Systems

ACCESSORIES

Page 7: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

SCENTROID

7

IN-FIELD ANALYSIS

IN-LAB ANALYSIS

Ultra-portable, weighing only 4 lbs.Measure odors as low as 2 OUs.and as high as 30,000 OUsComparable results to lab based olfactometer.

Very easy to use and maintain.Capable of conducting panel screening using n-butanol.

In-Field Odour Measurement

How it works

4. Stainless steel venturi pump creates the vacuum to draw in the sample air.

6. Mask always has positive pressure to ensure zero leaks of ambient air.

The SM110 can be used to analyze samples from:

directly from ambient air.

CAPABILITIES

.

.

.

.

Page 8: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

SCENTROID

CASE STUDY

Test 1 : Ease of use3 local candidates were chosen with no previous olfactometer experience.Brief training was provided to each candidate (10 min).Candidates were asked to measure the same sample bags consecutively

Result:All panelist were able to operate the machine properly.Total variation in measured odour strength was less than 30%.Minimal training and capacity to conduct n-butanol screening allows local population to act as panellist.

Test 2: RepeatabilityA sample was taken from the ducts of the HVAC system using the lung principle.Sample was analyzed once undiluted and again with dilution of 1:20 (sample to fresh air).Same panelist was used in both tests.

Result:Undiluted: 1553 OUDiluted: 1554 OUUnit is repeatable over its full measurement range

Test 3: Compatibility

FISHMEAL FACTORY

Odour measurements were made by the SM100C and compared toresults of tests made in 2002-2007 using Purenviro’s accreditedEN13725 laboratory.

Result:SM100C: 3806 OULaboratory Results: 3300-7200 OU

Following study was conducted by Dr. Knut Wiik from Purenviro in Stavern, Norway.4 case studies were conducted to measure accuracy, repeatability, and ease of use of the

8

1

Page 9: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

SCENTROID

Test 1: Compatibility

site and measured using both EN13725 laboratory and SM100C.Result:SM100C: 10000 OULaboratory Results: 13000 OU

Recycling FacilityTest 2: Compatibility

recycling waste and measured using both EN13725 laboratory and SM100C.

Result:SM100C: 30 OULaboratory Results: 45 OU

Test 1: CompatibilityFollowing studies was conducted by Anna Bokowa Engineering Consulting in Canada and presented in WEF odour conference 2012.Samples received from clients were tested using an 8 panel olfactometer and the SM100C. All samples were compared in the same day.

The SM100 is light (4lbs) and portable Can measure ambient odours as low as 2 OUCan analyse stack odours as high as 30,000 without pre-dilutionSmall dilution steps to achieve higher accuracy (e.g. 2,3,4,5,6)Self-contained and does not require any additional sampling equipmentCapable of screening panellists using n-butanol

Lower capital and operational costsElimination of sample degradation caused by sample shipment (time,temperature and pressure imposed during shipping).Use of local population as panellist

Conclusion

9

BIO FILTER CANADA

SM100

LAND FILLCASE STUDY

CASE STUDY

2

3

Page 10: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

PRODUCTION LINE

Page 11: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

SM10

0 FOR

STAC

K TE

STIN

G

Page 12: SCENTROiD SM100 - · PDF fileSM100 uses no electronic components and incorporable the highest grade of industrial components for the highest level of reliability. SM100 is built to

20

IDES CANADA INC. IDES CANADA

431 Alden Rd., Unit 3, Markham, ON, L3R 4C1

Contact:Local: 416.479.0078

Toll-Free: 1.888.988.IDES (4337)www.scentroid.ca

Professional Odour Measurement Equipment

SCENTROiD