94
Product Catalog Turnkey systems and solutions for photovoltaic power plants Our systems and solutions for photovoltaic power plants

Sat control catalog 9.11.2012

Embed Size (px)

DESCRIPTION

Sat control catalog 9.11.2012

Citation preview

Page 1: Sat control catalog 9.11.2012

ProductCatalog

Turnkey systems and solutions for photovoltaic power plants

Our systems and solutions for photovoltaic power plants

Page 2: Sat control catalog 9.11.2012

General Terms and Conditions

Dear Customers,

Photovoltaic electricity, once confi ned to space exploration, has since the beginning of the 21st century,

gained access to the realm of power generation.

The impressive growth of the PV market, mainly driven during those years by the European interest for

this particular technology, has since then led to a major decrease in system prices, bringing PV technology

among the emerging technologies for power generation on a large scale.

At Sat Control we are proud to be one of the fi rst companies worldwide to successfully implement innova-

tive, cost-effective, reliable, robust and active solar tracking systems in the world.

Sat Control accelerates technological innovations by industry led research and development tracking sys-

tems offering outstanding long-term performance. Sat Control provides solutions that demonstrate cost

effectiveness, added value, and go beyond the business. Setting the highest quality standards is Sat Con-

trol’s main objective.

Sat Control products are a result of intensive research and development efforts, manufactured in a state of

the art automated production environment and comply with the principal international standards: Interna-

tional Protection Rating (IEC 60529 IP33), Electromagnetic Compatibility (EMC Directive 89/336/EEC) and

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC).

Components and materials used in production originate from well established suppliers, are pre-certifi ed,

tested and meet the highest quality standards. Due to the strict quality control at each step of the produc-

tion process, Sat Control is able to offer its customers up to 10-year product warranty.

Headquartered in Slovenia, at Sat Control we fi nd our place predominantly in diverse international mar-

kets. Tracker installations of every size have been deployed internationally, including utility-scale projects

in more than 45 countries over the world including Germany, France, Italy, Slovakia, Czech Republic, Aus-

tralia, India, Canada and the United States.

Sat Control’s strategic goal is to become globally innovative and competitive Solar Energy enterprise,

providing the most appropriate solar tracking technology for achieving the highest performance and most

cost-effective production of solar electricity.

Bogdan Bolka

CEO of Sat Control

Page 3: Sat control catalog 9.11.2012
Page 4: Sat control catalog 9.11.2012

Table of Contents

1. SOLAR LINEAR TRACKERS

1.a. DUAL AXIS SOLAR TRACKERS

1.a.1. SM44M3V15P ..................................................................... page 1-2 1.a.2. SM54M1V6P ....................................................................... page 3-6 1.a.3. SM44M1V4P ....................................................................... page 7-10 1.a.4. SM44M1V3P ....................................................................... page 11-14 1.a.5. SM44M1V2P ....................................................................... page 15-18 1.a.6. Iron-Reinforcement Cage ..................................................... page 19-20

1.b. SINGLE AXIS SOLAR TRACKERS

1.b.1. SM40M1V4P ....................................................................... page 21-24 1.b.2. SM40M1V3P ....................................................................... page 25-28 1.b.3. SM40M1V2P ....................................................................... page 29-32 1.b.4. SM3SPMOG+ ..................................................................... page 33-36

2. SOLAR PANELS

2.a.1. PV panel polycrystalline JC250M-24/Bb .................................. page 37-38 2.a.2. PV panel polycrystalline JC300M-24/Ab ................................. page 39-40 2.a.3. PV panel monocrystalline JC250S-24/Bb ................................ page 41-42 2.a.4. PV panel polycrystalline JC200S-24/Db .................................. page 43-44

2.a.5. PV panel HJM195M-24 ........................................................ page 45-46

2.a.6. PV panel HJM250M-32 ......................................................... page 47-48 2.a.7. PV panel HJM180D-36 ......................................................... page 49-50

3. SOAR HELIOSTATS

3.a. SM44M1HEL3M ...................................................................... page 51-52 3.b. SM44M1HEL6M ..................................................................... page 53-54 3.c. SM44M3HEL25M .................................................................... page 55-56

4. SOLAR LINEAR MOTORS ACTUATORS

4.a. Motor SM4S520M1 ................................................................. page 57-58 4.b. Motor SM4S900M3C3 - with Clamp C3 ...................................... page 59-60 4.c. Motor SM4S900M3C4 - with Clamp C4 ..................................... page 61-62 4.d. Motor SM4S900M3NC - without Clamp ..................................... page 63-64

Page 5: Sat control catalog 9.11.2012

5. SOLAR POSITIONERS

5.a. SOLAR POSITIONER 2-AXIS MODULE NANO .............................. page 65-66 5.b. SOLAR POSITIONER 2-AXIS MODULE MICRO .............................. page 67-68 5.c. SIGMA SOLAR SERVER ............................................................ page 69-70 5.d.1. SMPS Power supply TDK - Lambda DPP 50-24 ......................... page 71-71 5.d.2. SMPS Power supply TDK - Lambda DPP 100-24 ....................... page 71-71 5.d.3. SMPS Power supply TDK - Lambda DPP 480-24-3 .................... page 72-72 5.e. Junction Box (j-box) Set & 5.f. Connection Board Sestiv 39B ........ page 73-74 5.g. USB 2.0 to RS485 Mini Adapter with Terminal Block .................... page 75-75 5.h. Cable USB 2.0 - USB-A -› Micro-B ............................................ page 76-76 5.i. Wind sensor WS XS Vestmatic .................................................. page 77-77 5.j. Plastic mounting bracket for wind sensor ................................... page 78-78

6. GROUND SCREWS

6.a. GROUND SCREW ................................................................... page 79-81 6.b. SET GROUND SCREWS ........................................................... page 82-84

7. MONITORING SYSTEM

7.a. HELIOS ANALYTICS ............................................................... page 85-86

8. SAT CONTROL WEBSHOP

8.a. SAT CONTROL WEBSHOP ....................................................... page 87-88

Page 6: Sat control catalog 9.11.2012

1.a.1. SM44M3V15P

Product code: SM44M3V15P

Dual-Axis Solar Tracker SM44M3V15P

Dual-Axis Solar Tracker SM44M3V15P with accuracy better than 0,5 deg and backstructure for 15 pieces of

solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 25 m2 solar panel

surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses,

trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial

and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.

In a Year basis with Dual axis motor you can get 7% more income of energy compared to Single axis motor.

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1

Page 7: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚

Type of hour-angle engine Linear Motor SM4S900M3 with stroke of 900 mm

Type of elevation shaft and stroke Linear motor SM4S900M3 with stroke of 900mm

Hour-angle shaft diameter and length Square tube 200x200 mm, L=2280 mm (steel)

Turning speed of hour angle shaft /

Turning speed of elevation shaft /

Max. dynamic torque of the hour-angle shaft /

Max. dynamic torque of elevation shaft /

Destructive torque of the hour-angle shaft /

Destructive torque of elevation shaft /

Backstructure size 5 x 5 m (H size 4 x 2,45 m)

Type of backstructure clamp Toothed scissors gripers - 60 pcs

Tube diameter for mounting Square tube 200x200 mm, H=3500 mm (steel)

Max. dimensions of a solar panel 15 pieces of 0.99 m x 1.67 m in total 25 m2

Max. weight of a solar panel 15 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval 1 minute (0.25°)

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ±15% 4A(5A current capacity)

Backup battery CR 2512 coin

Turning time interval 1 minute (0.25°)

Max. Current of elevation shaft /

Standby consumption (when is not moving) 60mA @ 24 VDC

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1.5mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130km/h (in vertical position) up to 180km/h (in horizontal position)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 5000 (L) x 800 (W) x 800 (H) mm (Wooden Box is not icluded with kit)

Product weight 750kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included

Heliostat usage Yes, for additional payment

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

2

Technical Capabilities

Page 8: Sat control catalog 9.11.2012

1.a.2. SM54M1V6P

Product code: SM54M1V6P

Dual Axis Solar Tracker SM54M1V6P

Dual-Axis Solar Tracker SM54M1V6P with accuracy better than 0,5 deg and backstructure for 6 pieces of solar panels dimensions 0,808 m x 1,580 m and weight of 25 kg max each. So together for 7,65 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at small and large solar power plants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 130km/h. In a Year basis with 2 axis motor you can get 7% more income of energy compared to single axis motor. Solar tracker anti-shadowing software func-tion included.

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

3

Page 9: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Dual-Axis, Azimuth-Elevation System

Azimuth Angle Limit 270˚

Elevation angle 90˚

Type of Azimuth-angle engine Slew drive SM5M1

Type of elevation shaft and stroke Linear motor SM4S520M1

Azimuth-angle shaft diameter and length /

Turning speed of Azimuth angle shaft 0,9˚/s

Turning speed of elevation shaft 0,052 - 0,062 °/s at no load

Max. dynamic torque of the Azimuth-angle shaft Azimuth 150 Nm

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA

Destructive torque of the Azimuth-angle shaft 1500 Nm

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA

Backstructure size 2,424 m x 3,160 m

Type of backstructure clamp Toothed gripers - 24 pcs

Tube diameter for mounting Ø133 x 3 mm

Max. dimensions of a solar panel Array of 6 pieces of 0,808 m x 1,580 m in total 7,65 m2

Max. weight of a solar panel 6 pcs per 25 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Communication Data

Type of communication interface RS485

Networking solution for control from centre RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery /

Turning time interval 5 sec - 15 minute, but controlled via Sigma Solar Server Web based

Max. consumption during the operation of the Azimuth-angle shaft 500 mA @ 150 Nm

Max. Current of elevation shaft 500 mA @ 400Nm

Standby consumption (when is not moving) 25 mA ± 25% @ 24V

Power supply connection 1 cable of 2 wires with an Internal Cu Conductor of 1,0 mm2 for power and 1 twisted pair 0,25mm2 (2 wires) (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Neutral Salt Spray (3000 h, EN ISO 9227 NSS) /

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product /

Product weight 155kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, but controlled via Sigma Solar Server Web based

Heliostat usage Yes, but controlled via Sigma Solar Server Web based

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

4

Technical Capabilities

Page 10: Sat control catalog 9.11.2012

1.a.2. SM54M1V6P

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

5

Page 11: Sat control catalog 9.11.2012

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 1.17 kWp (producer spec. at AM 1.5) Date: May 2011 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 4890.6Wh Average energy of motorized: 7920.9Wh

Note: Sum of motor energy consumption through all day is 35.5Wh or 0.22% of all collected energy.

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

6

1.a.2. SM54M1V6P

Page 12: Sat control catalog 9.11.2012

1.a.3. SM44M1V4P

Product code: SM44M1V4P

Dual Axis Solar Tracker SM44M1V4P

Dual Axis Solar Tracker SM44M1V4P with accuracy better than 0,5 deg and backstructure for 4 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 7,7 m2 solar panel sur-face. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with 2 axis motor you can get 7% more income of energy compared to single axis motor. Solar tracker anti-shadowing software function included.

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

7

Page 13: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Turning speed of elevation shaft 0,052 - 0,062 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 Nm - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 4000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 16 pcs

Tube diameter for mounting Ø76,1 x 3,6 mm with reduced tube to Ø68 mm (not included with kit)

Max. dimensions of a solar panel 4 pieces of 0,99 m x 1,95 m in total 7,7 m2

Max. weight of a solar panel 4 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm & 1 box of 2050 (L) x 180 (W) x 70 (H) mm

Product weight 55 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included

Heliostat usage Yes, for additional payment

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

8

Technical Capabilities

Page 14: Sat control catalog 9.11.2012

1.a.3. SM44M1V4P

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

9

Legend:

Legend:

Legend:

Page 15: Sat control catalog 9.11.2012

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 1.2 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

1.a.3. SM44M1V4P

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

10

Legend:

Legend:

Page 16: Sat control catalog 9.11.2012

1.a.4. SM44M1V3P

Product code: SM44M1V3P

Dual-Axis Solar Tracker SM44M1V3P

Dual-Axis Solar Tracker SM44M1V3P with accuracy better than 0,5 deg and backstructure for 3 pieces of solar

panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface.

A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic sig-

nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and

output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual Axis motor you can get 7% more income of energy compared to Single Axis motor.

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

11

Page 17: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Turning speed of elevation shaft 0,052 - 0,062 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 Nm - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 3000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 12 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel 3 pieces of 0,99 m x 1,95 m in total 5,8 m2

Max. weight of a solar panel 3 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 45 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Technical Capabilities

12

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

Page 18: Sat control catalog 9.11.2012

1.a.4. SM44M1V3P

Legend:

Legend:

Legend:

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

13

Page 19: Sat control catalog 9.11.2012

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

1.a.4. SM44M1V3P

Legend:

Legend:

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

14

Page 20: Sat control catalog 9.11.2012

1.a.5. SM44M1V2P

Product code: SM44M1V2P

Dual-Axis Solar Tracker SM44M1V2P

Dual-Axis Solar Tracker SM44M1V2P with accuracy better than 0,5 deg and backstructure for 2 pieces of solar

panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 4,0 m2 solar panel surface.

A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic sig-

nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and

output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual Axis motor you can get 7% more income of energy compared to Single Axis motor.

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

15

Page 21: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Turning speed of elevation shaft 0,052 - 0,062 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 Nm - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 2000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 8 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel 2 pieces of 0,99 m x 1,95 m in total 3,9 m2

Max. weight of a solar panel 2 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 35 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included

Heliostat usage Yes, for additional payment

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

16

Technical Capabilities

Page 22: Sat control catalog 9.11.2012

1.a.5. SM44M1V2P

Legend:

Legend:

Legend:

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

17

Page 23: Sat control catalog 9.11.2012

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 0.6 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 2508,0Wh Average energy of motorized: 4062,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.43% of all collected energy.

1.a.5. SM44M1V2P

Legend:

Legend:

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

18

Page 24: Sat control catalog 9.11.2012

1.a.6. Iron-reinforcement cage JEKABBSM44M3V15P

Product code: JEKABBSM44M3V15P

Iron-reinforcement cage for Overground Concrete Foundation for Solar Tracker SM40M3V15P

The foundation of the solar power system can take various forms. Consequently, optimum consideration can

be given to the local conditions.

The rectangular overground foundation is generally used if a stony or rocky substrate precludes an under-

ground variant of the foundation structure.

1. IRON - REINFORCEMENT CAGE

19

Page 25: Sat control catalog 9.11.2012

1. IRON - REINFORCEMENT CAGE

20

Technical Capabilities

1.a.6. Iron-reinforcement cage JEKABBSM44M3V15P

Page 26: Sat control catalog 9.11.2012

1.b.1. SM40M1V4P

Product code: SM40M1V4P

Single-Axis Solar Tracker SM40M1V4P

Single-Axis Solar Tracker SM40M1V4P with accuracy better than 0,5 deg and backstructure for 4 pieces of

solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 7,7 m2 solar panel

surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses,

trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial

and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.

In a year basis with Dual Axis motor you can get 7% more income of energy compared to Single Ais motor.

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

21

Page 27: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Single-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the le shaft 200 - 330 Nm depend from HA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 4000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 16 pcs

Tube diameter for mounting Ø76,1 x 3,6 mm with reduced tube to Ø68 mm (not included with kit)

Max. dimensions of a solar panel 4 pieces of 0,99 m x 1,95 m in total 7,7 m2

Max. weight of a solar panel 4 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm & 1 box of 2050 (L) x 180 (W) x 70 (H) mm

Product weight 52 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included

Heliostat usage No

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

22

Technical Capabilities

Page 28: Sat control catalog 9.11.2012

1.b.1. SM40M1V4P

Legend:

Legend:

Legend:

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

23

Page 29: Sat control catalog 9.11.2012

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 1.2 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

1.b.1. SM40M1V4P

Legend:

Legend:

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

24

Page 30: Sat control catalog 9.11.2012

1.b.2. SM40M1V3P

Product code: SM40M1V3P

Single-Axis Solar Tracker SM40M1V3P

Single-Axis Solar Tracker SM40M1V3P with accuracy better than 0,5 deg and backstructure for 3 pieces of solar

panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface.

A Suitable for PV panels, concentrators - CPV. Usage at homes: on-grid at roof on houses, trafic signalisations,

street light, cottages, small and large powerplants where solar panels are connected in serial and output is

connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

25

Page 31: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Single-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 3000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 12 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel 3 pieces of 0,99 m x 1,95 m in total 5,8 m2

Max. weight of a solar panel 3 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2,5A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 41 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included

Heliostat usage No

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

26

Technical Capabilities

Page 32: Sat control catalog 9.11.2012

1.b.2. SM40M1V3P

Legend:

Legend:

Legend:

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

27

Page 33: Sat control catalog 9.11.2012

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

1.b.2. SM40M1V3P

Legend:

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

28

Page 34: Sat control catalog 9.11.2012

1.b.3. SM40M1V2P

Product code: SM40M1V2P

Single-Axis Solar Tracker SM40M1V2P

Single-Axis Solar Tracker SM40M1V2P with accuracy better than 0,5 deg and backstructure for 2 pieces of

solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 4,0 m2 solar panel

surface. A Suitable for PV panels, concentrators - CPV. Usage at homes: on-grid at roof on houses, trafic sig-

nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and

output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

29

Page 35: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Single-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 2000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 8 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel 2 pieces of 0,99 m x 1,95 m in total 3,9 m2

Max. weight of a solar panel 2 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ ***)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery Backup for timer, position and data

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 35 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included

Heliostat usage No

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

30

Technical Capabilities

Page 36: Sat control catalog 9.11.2012

1.b.3. SM40M1V2P

Legend:

Legend:

Legend:

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

31

Page 37: Sat control catalog 9.11.2012

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 0.6 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 2508,0Wh Average energy of motorized: 4062,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.43% of all collected energy.

1.b.3. SM40M1V2P

Legend:

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

32

Page 38: Sat control catalog 9.11.2012

1.b.4. SM3SPMOG+

Product code: SM3SPMOG+

Solar Tracker SM3SPMOG+

Single-Axis Solar Tracker SM3SPMOG+ made to be supplied with power from 12 to 69 VDC from external

power supply. Without charger controller. Suitable for panels on grid Up to dimensions 2m x 1m usage at

homes on-grid at roof on houses, for trafic signalisation, for street light use, for power suplly at cottages, for

small and large powerplants where solar panels are connected in serial and output is connected directly to

inverter or an external charging device. Minimal wind resistance is 180km/h is required and price is imporant

too. All metal gear parts inside ensure high destruction forces.

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

33

Page 39: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Single-Axis

Hour Angle Limit 96˚ typical / 100˚ max., software and hardware limit

Elevation angle 75° manual fixation

Type of hour-angle engine Servo motor with position encoder on cogwheel

Hour-angle shaft diameter and length Ø40 mm, L=1150 mm (steel)

Turning speed of hour angle shaft 0,5°/s ± 25% @ 24V at no load

Max. dynamic torque of the hour-angle shaft 65 Nm

Destructive torque of the hour-angle shaft >200 Nm

Backstructure size 2 pcs of 1000 (H) mm

Type of backstructure clamp Toothed scissors gripers - 4 pcs

Tube diameter for mounting Ø50,0 - 60,0 mm

Max. dimensions of a solar panel 1 piece of 2,0 m x 1,0 m in total 2,0 m2

Max. weight of a solar panel 1 pc per 25 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of Positioner Solar Positioner SP27C

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval 1 minute (0,25°)

Communication Data

Type of communication interface USB interface since beginning of the January 2010, before RS232

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply Recommended 24 VDC (working from 12 to 69 VDC), (2,5 A current capacity @ 12V)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 65 Nm

Standby consumption (when is not moving) 35 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Packaging

Dimensions of a packed product 1 box of 1175 (L) x 135 (W) x 200 (H) mm

Product weight 9 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included

Heliostat usage No

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

34

Technical Capabilities

Page 40: Sat control catalog 9.11.2012

1.b.4. SM3SPMOG+

● G.L. and +15˚ or -15˚ according to the season

● SET TO THE CALCULATED ANGLE● FOR EXAMPLE: 45˚

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

35

Page 41: Sat control catalog 9.11.2012

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 200W (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 836,8Wh Average energy of motorized: 1354,0Wh

Note: Sum of motor energy consumption through all day is 20Wh or 1.45% of all collected energy.

1.b.4. SM3SPMOG+

Legend:

1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

36

Page 42: Sat control catalog 9.11.2012

2.a.1. PV panel polycrystalline JC250M-24/Bb, 40mm frame

Product code: PVPJC250M24BB

PV panel polycrystalline JC250M-24/Bb

Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and stand-

alone systems. The modules characterized by outstanding longterm performance are designed to withstand

rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate

is granted.

2. SOLAR PANELS

37

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

100%

95%

90%

85%

80%

0%

25

Per

form

ance

Fig

ure

s in

%

YEAR

0 1

97.5%

97

.5%

5 10 15 20

Added

Value

80.0%

LinearPerformanceWarranty

TraditionalWarranty

Page 43: Sat control catalog 9.11.2012

2. SOLAR PANELS

38

Cu

rre

nt(

A)

Voltage (V)

Efficiency 15.5% 15.9% 15.9% 15.8% 15.7%

Irradiance 200W/m 2 400W/m 2 600W/m 2 800W/m 2 1000W/m 2

992mm

1640

mm

86

0m

m

136

0m

m

100

0m

m

40mm 947mm

JUNCTION BOX

LABLE

8- 9X5

16-8X3.5

2- 4

INSTALLING HOLE

DRAIN HOLE

GROUNDING HOLE

4-7.5X7.5DRAIN HOLE

0 5 1 0 1 5 20 25 30 35 400

2

4

6

8

1 0

200W/m2

400W/m2

600W/m2

800W/m 2

1 000W/m2

• Dimensions • Curves

Varied Irradiation Efficiencies

JC250M-24/Bb250 W

0 ~ +5W

15.4%

8.31 A

30.1 V

8.83 A

37.4 V

JC255M-24/Bb255 W

0 ~ +5W

15.7%

8.39 A

30.4 V

8.86 A

37.5 V

Electrical Characteristics NOCTMaximum Power (Pmax)

Maximum Power Current (lmp)

Maximum Power Voltage (Vmp)

Short Circuit Current (lsc)

Open Circuit Voltage (Voc)

Values at Normal Operating Cell Temperature, Irradiance of 800 W/m2 , spectrum AM 1.5, ambient temperature 20oC, wind speed 1 m/s

JC250M-24/Bb185 W

6.57 A

28.2 V

7.12 A

35.0 V

JC255M-24/Bb189 W

6.63 A

28.5 V

7.20 A

35.1 V

Mechanical CharacteristicsCell Type

Glass

Frame

Junction Box

Dimension

Output Cable

Weight

Installation Hole Location

156 x156 mm Polycrystalline, 60 (6x10) pcs in series

High Transmission, Low lron, Tempered Glass

Anodized Aluminum Alloy

IP65/IP67 rated, with bypass diodes

*1640 x 992 x 40 mm

4 mm2 (EU)/12 AWG (US), 1000 mm

19 Kg

See Drawing Above

CharacteristicsTemperature Coefficient of Voc

Temperature Coefficient of Isc

Temperature Coefficient of Pmax

Nominal Operating Cell Temperature (NOCT)

Packing InformationContainer

Pallets per Container

Pieces per Container

20’ GP

12

300

40’ GP

28

700

40’ HQ

28

770

Maximum RatingsOperating Temperature

Maximum System Voltage

Maximum Series Fuse Rating

Page 44: Sat control catalog 9.11.2012

2.a.2. PV panel polycrystalline JC300M-24/Ab, 40mm frame

Product code: PVPJC300M24AB

PV panel polycrystalline JC300M-24/Ab

Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and stand-

alone systems. The modules characterized by outstanding longterm performance are designed to withstand

rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate

is granted.

2. SOLAR PANELS

39

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005,IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

100%

95%

90%

85%

80%

0%

25

Per

form

ance

Fig

ure

s in

%

YEAR

0 1

97.5%97.5%

5 10 15 20

Added

Value

80.0%

LinearPerformanceWarranty

TraditionalWarranty

Page 45: Sat control catalog 9.11.2012

2. SOLAR PANELS

40

Cu

rre

nt

(A)

Voltage (V)

Efficiency 15.1% 15.5% 15.6% 15.6% 15.5%

Irradiance 200W/m 2 400W/m 2 600W/m 2 800W/m 2 1000W/m 2

992mm

117

6m

m

167

6m

m

100

0m

m

947mm

JUNCTION BOX

LABLE

8- 9X5

16-8X3.5

2- 4

INSTALLING HOLE

DRAIN HOLE

GROUNDING HOLE

4-7.5X7.5DRAIN HOLE

• Dimensions • Curves

Varied Irradiation Efficiencies

JC295M-24/Ab295 W

0 ~ +5W

15.2%

8.13 A

36.3 V

8.62 A

44.7 V

JC300M-24/Ab300 W

0 ~ +5W

15.5%

8.20 A

36.6 V

8.69 A

44.8 V

Mechanical CharacteristicsCell Type

Glass

Frame

Junction Box

Dimension

Output Cable

Weight

Installation Hole Location

156 x156 mm Polycrystalline, 72 (6x12) pcs in series

High Transmission, Low lron, Tempered Glass

Anodized Aluminum Alloy

IP65/IP67 rated, with bypass diodes

*1956 x 992 x 50 mm

4 mm2 (EU)/12 AWG (US), 1000 mm

29 Kg

See Drawing Above

CharacteristicsTemperature Coefficient of Voc

Temperature Coefficient of Isc

Temperature Coefficient of Pmax

Nominal Operating Cell Temperature (NOCT)

Packing InformationContainer

Pallets per Container

Pieces per Container

20’ GP

10

200

40’ GP

24

480

40’ HQ

24

528

Maximum RatingsOperating Temperature

Maximum System Voltage

Maximum Series Fuse Rating

195

6m

m

0 1 0 20 30 40 500

2

4

6

8

1 0

JC295M-24/Ab219 W

6.57 A

33.3 V

6.96 A

41.8 V

JC300M-24/Ab222 W

6.67 A

33.4 V

7.02 A

41.9 V

Page 46: Sat control catalog 9.11.2012

2.a.3. PV panel monocrystalline JC250S-24/Bb, 40mm frame

Product code: PVPJC250S24BB

PV panel monocrystalline JC250S-24/Bb

Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and stand-

alone systems. The modules characterized by outstanding longterm performance are designed to withstand

rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate

is granted.

2. SOLAR PANELS

41

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005,IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

100%

95%

90%

85%

80%

0%

25

Per

form

ance

Fig

ure

s in

%

YEAR

0 1

96.5%96.5%

5 10 15 20

Added

Value

80.0%

LinearPerformanceWarranty

TraditionalWarranty

Page 47: Sat control catalog 9.11.2012

2. SOLAR PANELS

42

Cu

rre

nt

(A)

Voltage (V)

Efficiency 15.9% 16.2% 16.2% 16.1% 16.0%

Irradiance 200W/m 2 400W/m 2 600W/m 2 800W/m 2 1000W/m 2

992mm

164

0m

m

86

0m

m

136

0m

m

100

0m

m

40mm 947mm

JUNCTION BOX

LABLE

8- 9X5

16-8X3.5

2- 4

INSTALLING HOLE

DRAIN HOLE

GROUNDING HOLE

4-7.5X7.5DRAIN HOLE

• Dimensions • Curves

Varied Irradiation Efficiencies

JC250S-24/Bb250 W

0 ~ +5W

15.4%

8.32 A

30.1 V

8.87 A

37.5 V

JC255S-24/Bb255 W

0 ~ +5W

15.7%

8.44 A

30.2 V

8.99 A

37.6 V

JC260S-24/Bb260 W

0 ~ +5W

16.0%

8.55 A

30.4 V

9.10 A

37.7 V

Mechanical CharacteristicsCell Type

Glass

Frame

Junction Box

Dimension

Output Cable

Weight

Installation Hole Location

156 x156 mm Monocrystalline, 60 (6x10) pcs in series

High Transmission, Low lron, Tempered Glass

Anodized Aluminum Alloy

IP65/IP67 rated, with bypass diodes

*1640 x 992 x 40 mm

4 mm2 (EU)/12 AWG (US), 1000 mm

19 Kg

See Drawing Above

CharacteristicsTemperature Coefficient of Voc

Temperature Coefficient of Isc

Temperature Coefficient of Pmax

Nominal Operating Cell Temperature (NOCT)

Packing InformationContainer

Pallets per Container

Pieces per Container

20’ GP

12

300

40’ GP

28

700

40’ HQ

28

770

Maximum RatingsOperating Temperature

Maximum System Voltage

Maximum Series Fuse Rating

0 5 1 0 1 5 20 25 30 35 400

2

4

6

8

10

JC250S-24/Bb184 W

6.57 A

28.0 V

7.15 A

35.1 V

JC255S-24/Bb188 W

6.62 A

28.4 V

7.21 A

35.2 V

JC260S-24/Bb191 W

6.66 A

28.7 V

7.28 A

35.3 V

200W/m˛

400W/m˛

600W/m˛

800W/m˛

1000W/m˛

Page 48: Sat control catalog 9.11.2012

2.a.4. PV panel monocrystalline JC200S-24/Db, 35mm frame

Product code: PVPJC200S24DB

PV panel monocrystalline JC200S-24/Db

Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and stand-

alone systems. The modules characterized by outstanding longterm performance are designed to withstand

rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate

is granted.

2. SOLAR PANELS

43

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005,IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

100%

95%

90%

85%

80%

0%

25

Per

form

ance

Fig

ure

s in

%

YEAR

0 1

96.5%96.5%

5 10 15 20

Added

Value

80.0%

LinearPerformanceWarranty

TraditionalWarranty

Page 49: Sat control catalog 9.11.2012

2. SOLAR PANELS

44

0 10 20 30 40 500

1

2

3

4

5

6

200W/m˛

400W/m˛

600W/m˛

800W/m˛

1000W/m˛

Cu

rre

nt

(A)

Voltage (V )

Efficiency 15.4% 15.8% 15.8% 15.8% 15.7%

Irradiance 200W/m 2 400W/m 2 600W/m 2 800W/m 2 1000W/m 2

808mm

158

0m

m

35mm

• Dimensions • Curves

Varied Irradiation Efficiencies

JC190S-24/Db190 W

0 ~ +5W

14.9%

5.19 A

36.6 V

5.49 A

44.9 V

JC195S-24/Db195 W

0 ~ +5W

15.3%

5.32 A

36.7 V

5.61 A

45.0 V

JC200S-24/Db200 W

0 ~ +5W

15.7%

5.41 A

37.1 V

5.70 A

45.3 V

Mechanical CharacteristicsCell Type

Glass

Frame

Junction Box

Dimension

Output Cable

Weight

Installation Hole Location

125 x125 mm Monocrystalline, 72 (6x12) pcs in series

High Transmission, Low lron, Tempered Glass

Anodized Aluminum Alloy

IP65/IP67 rated, with bypass diodes

*1580 x 808 x 35 mm

4 mm2 (EU)/12 AWG (US), 1000 mm

16 Kg

See Drawing Above

CharacteristicsTemperature Coefficient of Voc

Temperature Coefficient of Isc

Temperature Coefficient of Pmax

Nominal Operating Cell Temperature (NOCT)

Packing InformationContainer

Pallets per Container

Pieces per Container

20’ GP

12

372

40’ GP

28

868

40’ HQ

28

952

Maximum RatingsOperating Temperature

Maximum System Voltage

Maximum Series Fuse Rating

JC190S-24/Db140 W

4.13 A

34.0 V

4.42 A

42.1 V

JC195S-24/Db144 W

4.22 A

34.2 V

4.52 A

42.3 V

JC200S-24/Db147 W

4.27 A

34.5 V

4.60 A

42.4 V

Page 50: Sat control catalog 9.11.2012

2.a.5. Photovoltaic solar panel HJM195M-24

Product code: PVSPHJM195M24

PV panel monocrystalline HJM195M-24

The HJM195D-24, HJSOLAR Solar’s 195 watt photovoltaic module features 17-18% encapsulated cell efficien-

cy and 15.2% module efficiency. With a 25 year warranty, the HJM195D-24 has superb durability to withstand

rigorous operating conditions. Ideal for grid-connected and remote power systems, the HJM185D-36 modules

offer the maximum usable power per square foot of solar array.

2. SOLAR PANELS

45

35 (1.38)

808 (31.8)

4-6*6

8-14*9Mounting slots

16-3.5*8Waterspout

Ground hole

Waterspout

762 (30.0)

90 (3.54)

35 (1.38)

9 (0.35) 70 (2.76)

Cable

900mm 900mm

Cable

70 (2.76)

1580

(62.2

)

1300

(51.2

)

800 (

31.5)

130 (

5.12)

80 (3

.15)

Junction box(IP65)

Bar code

Lable

2- 4

Page 51: Sat control catalog 9.11.2012

2. SOLAR PANELS

46

Model type

Peak power (Pmax)

Cell type

Maximum power voltage (Vmp)

Maximum power current (Imp)

Open circuit voltage (Voc)

Short circuit current (Isc)

Maximum system voltage

Temp. Coeff. of Isc (TK Isc) Temp.

Coeff. of Voc (TK Voc) Temp.

Coeff. of Pmax (TK Pmax)

Normal operating cell temperature

Power tolerance

Standard test conditions (STC)

HJM190M-24 HJM195M-24 HJM200M-24190W 195W 200W

Mono Crystalline Silicon, 125mm x 125mm

TUV DC 1000V/UL DC600V

0.037 %/ °C

- 0.34 %/ °C

- 0.37 %/ °C

45 ± 2 °C

±3 %

AM1.5, 1000W/m2, Module Temperature 25 °C

Electrical Characteristics

Mechanical CharacteristicsDimension (mm)

Weight (kg)

Solar cells

1580 x 808 x 35

16.5

72 cells (125 mm x 125 mm) configured geometricallyfor a 6 x 12 matrix connected in series

900

Front: High transmission 3.2 mm tempered glass.Rear: White backsheet; Encapsulant: EVA.Construction

Packing ConfigurationContainer 20’ GP 40’ GP

Pieces per pallet

Pallets per container

Pieces per container

26

12

312

26

28

728

Current-Voltage & Power-Voltage CurveFeatures• High module conversion efficiency up to 15.7%.

• 25-year limited warranty on power output:

• 90% power output over 12 years

• 80% power output over 25 years

• Free from defects in materials and workmanship for 5 years

• Bypass diode minimizes the power drop caused by shade.

• Tempered glass, EVA resin, and weatherproof film, and

anodized aluminum frame for extended outdoor use.

• TUV UL Listings: UL 1703, IEC61215, IEC61730.

Output cable length (mm)

36.71

5.16

44.06

5.57

37.59

5.20

44.46

5.62

37.87

5.29

44.86

5.71

1000 W/m2 900 W/m2 800 W/m2

0 10 20 30 40 500

40

80

120

160

200

2406.0

5.0

4.0

3.0

2.0

1.0

0.0

Cur

rent

(A)

Pow

er (W

)

Voltage (V)

Page 52: Sat control catalog 9.11.2012

2.a.6. Photovoltaic solar panel HJM250M-32

Product code: PVSPHJM250M32

PV panel monocrystalline HJM250M-32

The HJM250M-32, HJSOLAR Solar’s 250 watt photovoltaic module features 17-18% encapsulated cell ef-

ficiency and 15.2% module efficiency. With a 25 year warranty, the HJM250M-32 has superb durability to

withstand rigorous operating conditions. Ideal for grid-connected and remote power systems, the HJM250M-

32 modules offer the maximum usable power per square foot of solar array.

2. SOLAR PANELS

47

45 (1.77)

1062 (41.8)

4-6*6

8-14*9Mounting slots

16-3.5*8Waterspout

Ground hole

Waterspout

1016 (40.0)

90 (3.54)

35 (1.38)

9 (0.35) 70 (2.76)

Cable

900mm 900mm

Cable

70 (2.76)

1580

(62.2

)

1300

(51.2

)

800 (

31.5)

130 (

5.12)

80 (3

.15)

Junction box(IP65)

Bar code

Lable

2- 4

Page 53: Sat control catalog 9.11.2012

2. SOLAR PANELS

48

Model type

Peak power (Pmax)

Cell type

Maximum power voltage (Vmp)

Maximum power current (Imp)

Open circuit voltage (Voc)

Short circuit current (Isc)

Maximum system voltage

Temp. Coeff. of Isc (TK Isc) Temp.

Coeff. of Voc (TK Voc) Temp.

Coeff. of Pmax (TK Pmax)

Normal operating cell temperature

Power tolerance

Standard test conditions (STC)

HJM250M-32 HJM255M-32 HJM260M-32250W 255W 260W

Mono Crystalline Silicon, 125mm x 125mm

TUV DC 1000V/UL DC600V

0.037 %/ °C

- 0.34 %/ °C

- 0.37 %/ °C

45 ± 2 °C

±3 %

AM1.5, 1000W/m2, Module Temperature 25°C

50.60

4.94

60.50

5.35

50.80

5.02

60.70

5.42

51.00

5.10

61.00

5.51

Electrical Characteristics

Mechanical CharacteristicsDimension (mm)

Weight (kg)

Solar cells

1580 x 1062 x 45

22

96 cells (125 mm x 125 mm) configured geometricallyfor a 8 x 12 matrix connected in series

900

Front: High transmission 3.2 mm tempered glass.Rear: White backsheet; Encapsulant: EVA.Construction

Packing ConfigurationContainer 20’ GP 40’ GP

Pieces per pallet

Pallets per container

Pieces per container

20

12

240

20

28

560

Current-Voltage & Power-Voltage Curve

1000 W/m 2 800 W/m 2 500 W/m 2

Cur

rent

(A)

Pow

er (W

)

Voltage (V)

6.0

5.0

4.0

3.0

2.0

1.0

0.00 10 20 30 40 50 60 70

0

50

100

150

200

250

300

Features• High module conversion efficiency up to 15.5%.

• 25-year limited warranty on power output:

90% power output over 12 years

80% power output over 25 years

Free from defects in materials and workmanship for 5 years

• Bypass diode minimizes the power drop caused by shade.

• Tempered glass, EVA resin, and weatherproof film, and

anodized aluminum frame for extended outdoor use.

• TUV UL Listings: UL 1703, IEC61215, IEC61730.

Output cable length (mm)

Page 54: Sat control catalog 9.11.2012

2.a.7. Photovoltaic solar panel HJM-180D-36

Product code: PVSPHJM180D36

PV panel monocrystalline HJM-180D-36

The HJM185D-36, HJSOLAR Solar’s 185 watt photovoltaic module features 18% encapsulated cell efficiency

and 15.5% module efficiency. With a 25 year warranty, the HJM185D-36 has superb durability to withstand

rigorous operating conditions. Ideal for grid-connected and remote power systems, the HJM185D-36 modules

offer the maximum usable power per square foot of solar array.

2. SOLAR PANELS

49

Page 55: Sat control catalog 9.11.2012

2. SOLAR PANELS

50

Model type HJM170D-36 HJM175D-36 HJM180D-36 HJM185D-36 HJM190D-36

W091W581W081W571W071)xamP(rewopkaeP

Cell type MonoCrystalline Silicon, 125mm x 125mm

seiresanisllec27sllecforebmuN

Weight 16.5 kg

mm54×808×0851snoisnemiD

Maximum power voltage (Vmp) 36.48 36.59 36.59 36.71 36.71

Maximum power current (Imp) 4.66 4.78 4.92 5.04 5.16

Open circuit voltage (Voc) 43.86 43.92 43.92 44.06 44.06

Short circuit current (Isc) 5.03 5.16 5.31 5.44 5.57

Maximum system voltage TUV DC 1000V/UL DC600V

/%900.0.pmeT)csIKT(csIfo.ffeoC.pmeT oC

Coeff. of Voc (TK Voc) Temp. -0.34%/ oC

/%73.0-)xamPKT(xamPfo.ffeoC oC

Normal Temperature 45±2 oC

PHYSICAL CHARACTERISTICS

ELECTRICAL CHARACTERISTICS

ELECTRICAL DATA

The electrical data applies to standard test conditions (STC): Irradiance at the module level of 1,000 W/m2 withspectrum AM 1.5 and a cell temperature of 25° C

00

10

1

2

3

4

5

6 240

200

150

120

60

40

020 30 40 50

Voltage(V)

Curr

ent(

A)

Pow

er(W

)

800W/m˛

1000W/m˛900W/m˛

-25

0

0

20

40

60

80

100

25 50 75 100

Nor

mal

ize

Isc,

Voc

and P

max

(%)

Pow

er(W

)

ISC

PmaxVoc

Voc

ISC

Pmax

0

0

200

20

40

60

80

100

400 600 800 1000

Irradiance(W/m˛)

Nor

mal

ize

Isc,

Voc

and P

max

(%)

Temperature dependence of Isc, Voc and Pmax

Page 56: Sat control catalog 9.11.2012

3.a. SM44M1HEL3M

Product code: SM44M1HEL3M

Single-Axis Solar Heliostat SM44M1HEL3M

Dual-Axis Solar Heliostat SM44M1HEL3M for mirror application up to 3,1m2 enable cost-effective large-scale

sun tracking all over the course of the day with unprecedented accuracy.

3. SOLAR HELIOSTATS

51

Page 57: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 1.250 (H) mm x 1.500 (V) mm

Type of backstructure clamp Toothed scissors gripers 4 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a mirror panel 1 mirror panel with dimensions of 1.250 mm x 2.500 mm with net surface of 3,1 m2

Max. weight of a mirror panel 90 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,1˚

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Communication Data

Type of communication interface USB interface

Networking solution for control from centre RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Turning time interval Tipicaly 6 - 7 s

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 45 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function No

Solar Mirror Solar Mirror SolReflex® HM3C1M-3 for additional payment

3. SOLAR HELIOSTATS

52

Technical Capabilities

Page 58: Sat control catalog 9.11.2012

3.b. SM44M1HEL6M

Product code: SM44M1HEL6M

Single-Axis Solar Heliostat SM44M1HEL3M

Dual-Axis Solar Heliostat SM44M1HEL6M for mirror application up to 6,2m2 enable cost-effective large-scale

sun tracking all over the course of the day with unprecedented accuracy.

3. SOLAR HELIOSTATS

53

Page 59: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 2.500 (H) mm x 1.500 (V) mm

Type of backstructure clamp Toothed scissors gripers 8 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a mirror panel 2 mirror panels with dimensions of 1.250 mm x 2.500 mm with net surface of 6,2 m2

Max. weight of a mirror panel 90 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,1˚

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Communication Data

Type of communication interface USB interface

Networking solution for control from centre RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Turning time interval Tipicaly 6 - 7 s

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 45 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function No

Solar Mirror Solar Mirror SolReflex® HM3C1M-3 for additional payment

3. SOLAR HELIOSTATS

54

Technical Capabilities

Page 60: Sat control catalog 9.11.2012

3.c. SM44M3HEL25M

Product code: SM44M3HEL25M

Single-Axis Solar Heliostat SM44M1HEL25M

Dual-Axis Solar Heliostat SM44M1HEL25M for mirror application up to 25m2 enable cost-effective large-scale

sun tracking all over the course of the day with unprecedented accuracy.

3. SOLAR HELIOSTATS

55

Page 61: Sat control catalog 9.11.2012

Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S900M3 with stroke of 900 mm

Type of elevation shaft and stroke Linear Motor SM4S900M3 with stroke of 900 mm

Hour-angle shaft diameter and length Square tube 110x110 mm, L=5000 mm (steel)

Turning speed of hour angle shaft /

Max. dynamic torque of the hour-angle shaft /

Max. dynamic torque of elevation shaft /

Destructive torque of the hour-angle shaft /

Destructive torque of elevation shaft /

Backstructure size /

Type of backstructure clamp Toothed scissors gripers 48 pcs

Tube diameter for mounting Square tube 200x200 mm, H=3500 mm (steel)

Max. dimensions of a mirror panel 8 mirror panels with dimensions of 1.250 mm x 2.500 mm with net surface of 25 m2

Max. weight of a mirror panel /

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,1˚

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Communication Data

Type of communication interface USB interface

Networking solution for control from centre RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24VDC +/- 15% 4A (5A current capability)

Backup battery CR 2512 coin

Turning time interval 1 minute (0.25°)

Max. consumption during the operation of the hour-angle shaft /

Max. Current of elevation shaft /

Standby consumption (when is not moving) 60mA @ 24 VDC

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product /

Product weight /

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function No

Solar Mirror Solar Mirror SolReflex® HM3C1M-3 for additional payment

3. SOLAR HELIOSTATS

56

Technical Capabilities

Page 62: Sat control catalog 9.11.2012

4.a. Motor SM4S520M1

4. SOLAR LINEAR MOTORS

57

Product code: Motor SM4S520M1

Professional Solar Linear Actuator - Motor SM4S520M1

Professional Solar Linear Actuator - Motor SM4S520M1. Standard precision 0,5 degrees. Advanced precision 0,1 degrees for addtional payment.

Suitable for PV panels, concentrators - CPV and Heliostats. Heliostats for addtional payment. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included.

Page 63: Sat control catalog 9.11.2012

4.a. Motor SM4S520M1

4. SOLAR LINEAR MOTORS

58

Mechanical Capabies

Construction material of linear motor Stainless steel tubes and spindle and high carbon steel

Spindle type and material ACME stainless spindle

Stroke lenght 520 mm

Max. static load 3400 N

Dynamic load capacity 1000 N

Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load 0,9 mm/s at no load, 0,4 mm/s at max. load

Resolution 380,8 pulses/mm (min step is 0,0026 mm)

Backlash max 0,2 mm

Electrical Data

Motor Power Supply 24VDC +/- 15% 0,2A (0,5A current capability)

Backup battery /

Turning time interval /

Power consumption in operation Tipicaly 3-6 W, max 10 W

Standby consumption (when is not moving) /

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included in kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Corrosion, weather and chemical resistance

Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation

Packaging

Dimensions of a packed product 1box of 1000(L) x 80(W) x 60(H) mm

Product weight 3,46 kg + 1 kg box weight

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Heliostat usage Yes, for additional payment

CPV usage (concentrated PV usage) Yes, all types including round parabolic - for additional payment

Guarantee time 2 years as standard, 5 years for +20% - for additional payment, 10 years for +35% - for additional payment

Technical Capabilities

Page 64: Sat control catalog 9.11.2012

4. SOLAR LINEAR MOTORS

4.b. Motor SM4S900M3C3 - with Clamp C3

59

Product code: Motor SM4S900M3C3

Professional Solar Linear Actuator - Motor SM4S900M3C3

Professional Solar Linear Actuator - Motor SM4S900M3C3. Standard precision 0,5 degrees. Advanced preci-sion 0,1 degrees for addtional payment.

Suitable for PV panels, concentrators - CPV, and heliostats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device.Solar tracker anti-shadowing software function included.

Page 65: Sat control catalog 9.11.2012

4. SOLAR LINEAR MOTORS

4.b. Motor SM4S900M3C3 - with Clamp C3

60

Mechanical Capabies

Construction material of linear motor Stainless steel tubes and spindle and high carbon steel

Spindle type and material ACME stainless spindle

Stroke lenght 900 mm

Max. static load 15000 N

Dynamic load capacity 8000 N

Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load 2,33 mm/s

Resolution 294 pulses/mm (min step is 0,0034 mm)

Backlash max 0,15 mm

Electrical Data

Motor Power Supply 24VDC +/- 15% 4A (5A current capability)

Backup battery /

Turning time interval /

Power consumption in operation Tipicaly 20-50 W, max 100 W

Standby consumption (when is not moving) /

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included in kit)

Environmental Data

Operating temperature -25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)

Operation at humidity 0% to 100%, relative humidity

Corrosion, weather and chemical resistance

Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 80 (W) x 80 (H) mm

Product weight 8,5 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Heliostat usage Yes

CPV usage (concentrated PV usage) Yes, all types including round parabolic

Guarantee time 2 years as standard, 5 years for +20% *** 10 years for +35% ***

Technical Capabilities

Page 66: Sat control catalog 9.11.2012

4. SOLAR LINEAR MOTORS

4.c. Motor SM4S900M3C4 - with Clamp C4

61

Product code: Motor SM4S900M3C4

Professional Solar Linear Actuator - Motor SM4S900M3C4

Professional Solar Linear Actuator - Motor SM4S900M3C4. Standard precision 0,5 degrees. Advanced preci-sion 0,1 degrees for addtional payment.

Suitable for PV panels, concentrators - CPV, and heliostats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device.Solar tracker anti-shadowing software function included.

Page 67: Sat control catalog 9.11.2012

4. SOLAR LINEAR MOTORS

4.c. Motor SM4S900M3C4 - with Clamp C4

62

Mechanical Capabies

Construction material of linear motor Stainless steel tubes and spindle and high carbon steel

Spindle type and material ACME stainless spindle

Stroke lenght 900 mm

Max. static load 15000 N

Dynamic load capacity 8000 N

Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load 2,33 mm/s

Resolution 294 pulses/mm (min step is 0,0034 mm)

Backlash max 0,15 mm

Electrical Data

Motor Power Supply 24VDC +/- 15% 4A (5A current capability)

Backup battery /

Turning time interval /

Power consumption in operation Tipicaly 20-50 W, max 100 W

Standby consumption (when is not moving) /

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included in kit)

Environmental Data

Operating temperature -25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)

Operation at humidity 0% to 100%, relative humidity

Corrosion, weather and chemical resistance

Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 80 (W) x 80 (H) mm

Product weight 8,5 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Heliostat usage Yes

CPV usage (concentrated PV usage) Yes, all types including round parabolic

Guarantee time 2 years as standard, 5 years for +20% *** 10 years for +35% ***

Technical Capabilities

Page 68: Sat control catalog 9.11.2012

4. SOLAR LINEAR MOTORS

4.d. Motor Motor SM4S900M3NC

63

Product code: Motor SM4S900M3NC

Professional Solar Linear Actuator - Motor SM4S900M3NC

Professional Solar Linear Actuator - Motor SM4S900M3NC. Standard precision 0,5 degrees. Advanced preci-sion 0,1 degrees for addtional payment.

Suitable for PV panels, concentrators - CPV, and heliostats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device.Solar tracker anti-shadowing software function included.

Page 69: Sat control catalog 9.11.2012

4. SOLAR LINEAR MOTORS

4.d. Motor Motor SM4S900M3NC

64

Mechanical Capabies

Construction material of linear motor Stainless steel tubes and spindle and high carbon steel

Spindle type and material ACME stainless spindle

Stroke lenght 900 mm

Max. static load 15000 N

Dynamic load capacity 8000 N

Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load 2,33 mm/s

Resolution 294 pulses/mm (min step is 0,0034 mm)

Backlash max 0,15 mm

Electrical Data

Motor Power Supply 24VDC +/- 15% 4A (5A current capability)

Backup battery /

Turning time interval /

Power consumption in operation Tipicaly 20-50 W, max 100 W

Standby consumption (when is not moving) /

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included in kit)

Environmental Data

Operating temperature -25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)

Operation at humidity 0% to 100%, relative humidity

Corrosion, weather and chemical resistance

Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 80 (W) x 80 (H) mm

Product weight 8,5 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Heliostat usage Yes

CPV usage (concentrated PV usage) Yes, all types including round parabolic

Guarantee time 2 years as standard, 5 years for +20% *** 10 years for +35% ***

Technical Capabilities

Page 70: Sat control catalog 9.11.2012

5.a. SOLAR POSITIONER NANO

5. SOLAR POSITIONERS

65

Product code: POZSOL34A1DR

(Solar Positioner NANO works only in connection with Solar server SIGMA!!!)

Solar Positioner NANO A for Dual Axis Tracking

With even better communication, usability and accuracy, the Solar Positioner NANO A set a new Positioning Accuracy Standards. With easy installation, safe operation, a simplified assembly concept, and RS485 plant communication: the new generation of positioners is ideally suited in mid-sized and large stand-alone grids. With the Sigma Server, Solar Positioner NANO A creates complete, integrated system for monitoring, diagnosis and configuration of the PV plant.

Professional• Drive and positioning of Dual Axis Solar Trackers • Integration of Sat Control equipment into existing control-room technology

Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability

Reliable• Direct communication with the Sigma Solar Server via RS485 Service Interface• Meets the requirements of the EU Medium-Voltage Directive for grid safety management

Page 71: Sat control catalog 9.11.2012

5. SOLAR POSITIONERS

66

Technical Capabilities

Operation

Geometrical Operation Dual Axis Positioner

Type Slave Positioner

Communication

Tracker communication RS485 MODBUS

Interfaces

RS485 2 Pin Connector (Grounding Option)

Max. number of controlled devices

Solar Tracker 64

Max. communication range

RS485 1000 m

Power supply

Power supply External Power Supply

Input voltage 24VDC +/- 10%

Power consumption Type 4 W / max. 12 W / 0,5 W Stand By

Environmental conditions in operation

Ambient temperature -20 °C ... +60 °C

Relative air humidity 0 % ... 45 %, non-condensing

General data

Dimensions (W / H / D) in mm 110 / 55 / 17

Weight 100 g

Mounting location Indoors

Mounting options DIN rail mounting

Status display LEDs

Hall signals 2 Hall signals per Axis

End switches 2 Switches per Axis (one required, one optional)

Manual buttons 2 (East-West, Reference)

Upgrading In The Field by RS485 MODBUS

Languages

Software language English

Language versions – manual German, English, French, Italian, Spanish; Slovenian

Features

Warranty 5 years

Certificates and approvals www.Solar-Motors.com

Technical Capabilities

5.a. SOLAR POSITIONER NANO

Page 72: Sat control catalog 9.11.2012

5.b. SOLAR POSITIONER MICRO

5. SOLAR POSITIONERS

67

Product code: POZSOL36A1DR

Solar Positioner MICRO (stand alone positioner) is settable with Helios Analytics monitoring programme!!!

Solar Positioner MICRO for Dual Axis Tracking

With even better communication, usability and accuracy, the Solar Positioner MICRO set a new Positioning Accuracy Standards. With easy installation, safe operation, a simplified assembly concept, USB tracker and RS485 plant communication: the new generation of positioners is ideally suited in single and middle size stand-alone grids. With the Sigma Server, Solar Positioner MICRO creates complete, integrated system for monitor-ing, diagnosis and configuration of the PV plant.

Professional• Drive and positioning of Dual Axis Solar Trackers • Integration of Sat Control equipment into existing control-room technology

Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability

Reliable• Direct communication with Helios Analytics• Meets the requirements of the EU Medium-Voltage Directive for grid safety management

Page 73: Sat control catalog 9.11.2012

5. SOLAR POSITIONERS

68

Technical Capabilities

Operationnergy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

Operation

Geometrical Operation Dual Axis Positioner

Type Stand Alone Positioner

Communication

Tracker communication USB, RS485 MODBUS

Interfaces

RS485 2 Pin Connector (Grounding Option)

Max. number of controlled devices

Solar Tracker 1

Max. communication range

RS485 1000 m

Power supply

Power supply External Power Supply

Input voltage 24VDC +/- 10%

Power consumption 2Type 4 W / max. 12 W / 0,5 W Stand By

Environmental conditions in operation

Ambient temperature -20 °C ... +60 °C

Relative air humidity 0 % ... 45 %, non-condensing

General data

Dimensions (W / H / D) in mm 110 / 55 / 17

Weight 100 g

Mounting location Indoors

Mounting options DIN rail mounting

Status display LEDs

Hall signals 2 Hall signals per Axis

End switches 2 Switches per Axis (one required, one optional)

Manual buttons 2 (East-West, Reference)

Upgrading In The Field by RS485 MODBUS, or by USB

Languages

Software language English

Language versions – manual German, English, French, Italian, Spanish; Slovenian

Features

Warranty 5 years

Certificates and approvals www.Solar-Motors.com

Technical Capabilities

5.b. SOLAR POSITIONER MICRO

Page 74: Sat control catalog 9.11.2012

5. SOLAR POSITIONERS

69

The standardized data interface for large-scale systems

Large-scale plants and PV power utility stations require customized monitoring solutions and need to link sys-tems and components into one joint control system. Sigma Server set new communication standard in the field of automation technology, that enables simple and reliable data exchange between products and applications. With the Sigma Solar Server, Sat Control equipment can be very easily integrated into compatible systems. Overview Professional• Visualization, control and monitoring of large-scale plants • Integration of Sat Control equipment into existing control-room technology Flexible• Data interface in accordance with the communication standards in the field of automation technology• Simple and fast installation, high reliability

5.c. Sigma Solar Server

Product code: POZSOLSIG1

(Sigma Solar Server works in connection with Solar Positioner NANO!!!)

Page 75: Sat control catalog 9.11.2012

5. SOLAR POSITIONERS

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

70

5.c. Sigma Solar Server

Communication

Communication with Enigma Analytics Ethernet

PC communication Ethernet

Tracker communication RS485

Interfaces

Analog and digital inputs 3 analog inputs / 3 open collector outputs

Ethernet 10/100 Mbit, RJ45

RS485 2 Pin Connector (grounding option)

Max. number of controlled devices

Solar Tracker 64

Max. communication range

Ethernet 100 m

RS485 1000 m

Power supply

Power supply External Power Supply

Input voltage 12VDC - 24VDC

Power consumption Type 4 W / max. 12 W

Environmental conditions in operation

Ambient temperature -20 °C ... +60 °C

Relative air humidity 0 % ... 45 %, non-condensing

Memory

Internal 0,5 MB

External SD card 2 GB

General data

Dimensions (W / H / D) in mm 110 / 55 / 17

Weight 100 g

Mounting location Indoors

Mounting options DIN rail mounting

Status display LEDs

Languages

Software language English

Language versions – manual German, English, French, Italian, Spanish; Slovenian

Features

Operation Integrated Web server (Internet browser)

Warranty 5 years

Certificates and approvals www.Solar-Motors.com

Technical Capabilities

Page 76: Sat control catalog 9.11.2012

5.d. Lambda; 1. DPP 50-24, 2. DPP 100-24, 3. DPP 480-24-3

5. SMPS Power supply TDK

71

1. TDK - Lambda DPP 50-24

A 50 watt, enclosed frame, single output DIN Rail mounted AC/DC power supply. This rail mount power sup-

ply has a 85-264 AC volt Wide-range input with power factor correction. The output(s) are rated 24.00v at

2.10a. It is industrial rated with an operating temperature range of -10 - 71 °C and up to 86% efficiency.

The DPP50-24 is Rohs 6/6 compliant and backed by a 2 year warranty.

Overview:

• 5 to 48 V Outputs • 50 mV Ripple and Noise • Parallel Up to 3 Units (100 W and Up) • Convection Cooled from –10°C Up to +71°C • Active Power Factor Correction (PFC) • Universal/Auto Select AC Input • Input Transient Protection IEC61000-4 • UL/CSA/EN60950-1 and CE Mark Safety Approvals • UL1310 Class 2 • UL508 Listed and Class 1, Div. 2

3. TDK - Lambda DPP 100-24

A 100 watt, enclosed frame, single output DIN Rail mounted AC/DC power supply.

Overview:

• PSU, AC/DC, DIN RAIL, 24V, 100W • Power Supply Output Type: Adjustable • No. of Outputs: 1 • Output Voltage: 24V • Output Current: 4.2A • Power Rating: 100W • Input Voltage VAC: 85V AC to 132V AC/170V AC to 264V AC • Length: 96.7mm • Width: 22.8mm • Height: 75mm • SVHC: No SVHC (20-Jun-2011) • Efficiency: 87% • Input Voltage: 85V AC to 132V AC , 170V AC to 264V AC • Output Voltage Max: 28.5V • Output Voltage Min: 22.5V

Page 77: Sat control catalog 9.11.2012

5. SMPS Power supply TDK

72

Technical Capabilities

Operationnergy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

2. TDK - Lambda DPP 480-24 (DIN Rail 24V 20A 480W)

A 480 watt, enclosed frame, single output DIN Rail mounted AC/DC power supply.

Overview:

• PSU, AC/DC, DIN RAIL, 24V, 480W, 3PH • Power Supply Output Type: Fixed • No. of Outputs: 1 • Output Voltage: 24V • Output Current: 20A • Power Rating: 480W • Input Voltage VAC: 340V AC to 575V AC • Length: 111.9mm • Width: 150mm • Height: 124mm • SVHC: No SVHC (20-Jun-2011) • Efficiency: 90% • Input Voltage: 340V AC to 575V AC • Output Voltage Max: 28.5V • Output Voltage Min: 22.5V

Page 78: Sat control catalog 9.11.2012

5. JUNCTION BOX

73

Junction Box (j-box) Set - Smart solution for solar tracker positioner connection

The Sat Control’s Junction Box (j-box) Set is designed to be compact and versatile without any compromise on its safety and reliability standards: Expanding on the proven technology of Sat Control’s positioning devices, it separate of both mechanical and electronic components of solar trackers and replaces Sat Control’s integrated positioner with external din rail positioners. Material wall mounting boxes: made of ABS technopolymer with high resistance to UV rays and broad temperature range enable its use even under extreme climatic conditions. Particular bottom guides for DIN rail, terminal block and plates enable its easy installation and make positioner settings entirely foolproof. User-friendly

• Separate of both mechanical and electronic components • Easy status reports and visualization via Transparent Lid • Can be integrated into existing and new Solar Trackers/PV plants

Simple

• Easily accessible connection area• Comfortable installation and commissioning • Free choice of mounting location

Durable

• High protection class IP65

5.e. Junction Box (j-box) Set

Product code: JBOXSETSPMN1-TC

Page 79: Sat control catalog 9.11.2012

5. JUNCTION BOX & CONNECTION BOARD SESTIV 39B

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

74

5.e. Junction Box (j-box) Set

General data

Internal dim. (W / H / D) in mm 190 / 140 / 70

Weight (without cables) 500 g

Max ø holes possible 4 x ø 18 mm

Lid screws (no. and type) 4 Insulated sealable Hinged (Inox)

Characteristics Halogen Free

Mounting site outdoors

Mounting options DIN-Rail mounted interfaces

Ambient Conditions

Ambient temperature -40 °C ... +85 °C / -40 °F ... +185 °F

Relative air humidity 100 % relative humidity (non-condensing)

Degree of protection (according to IEC 60529) IP65

Features

Smooth Sided junction box - Screwed Transparent Lid - IP 56 1

Din metal mounting rail 180(L) mm 1

Metric Thread Cable Glands Pg 9 TD (16 mm) TL (8 mm) 4

DIN Rail Mounted Fuse Holder VSV 4 4 mm2 440 V 1

DIN Rail Terminal Block VS 4-PE 4 mm 1

DIN Rail Bus bar Terminal Block 6x9 -–10P 2

Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt.

Certificates and approvals www.Solar-Motors.com

Accessories

PositionersSolar Positioner 2-axis mod. MICRO, USB-RS485, DIN rail opt.

Solar Positioner 2-axis mod. NANO, RS485, DIN rail opt.

CablesInt. Cable SM4M3 w con 7pins->OPEN, L=opt. 2x1+5x0.22 opt. (1 or 2 pcs depend on Actuators - length is at request)

Technical Capabilities

Product code: SESTIV39B

5.f. Connection Board Sestiv 39B

Page 80: Sat control catalog 9.11.2012

5. USB 2.0 to RS485

75

USB 2.0 to RS485 Mini Adapter with Terminal Block

Specifications • USB Specification 2.0 Compliant • Supports RS485 serial Interface • Data Transfer Rates from 300bps to 3Mbps • Enhanced ESD Specification: +/-15KV Human Body Model, +/-15KV IEC1000-4-2 Air Discharge, +/-8KV • • IEC1000-4-2 Contact Discharge • Supports Windows 98SE/ME/2k/XP/Vista/7/x64, Mac OSX, Linux 2.6.9+

Includes

• USB to RS485 Adapter • DB9 to 4-pin Terminal Block adapter • Driver Disk • 0,8m USB extension cable

5.g. USB 2.0 to RS485 Mini Adapter with Terminal Block

Product code: USB2RS485

Page 81: Sat control catalog 9.11.2012

5. CABLE USB2.0 - USB-A

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

76

5.h. Cable USB2.0 - USB-A -> Micro-B, 1,8m, black

Technical Capabilities

Cable USB2.0 - USB-A -> Micro-B, 1,8m, black

Specifications • CABLE, USB A M - MICRO B M, 1.8M • Cable Assembly Type:Computer Cables • Cable Length - Metric:1.8m • Cable Length:1.8m • Colour:Black • Connector Type A:USB A Male • Connector Type B:USB micro B male • Weight (kg): 0.06

Product code: KABUSBA-MB1.8

Page 82: Sat control catalog 9.11.2012

5. WIND SENSOR

77

Wind sensor WS XS Vestamatic

Specifications • Wind sensor for measuring wind speed • For plastic bracket mounting • Compatible with all Vestamatic central, awning and blind controls

Includes

• Wind sensor WS XS Vestamatic WSVM01100310 / 383106390209

5.i. Wind sensor WS XS Vestamatic

Product code: WSVM01100310

Page 83: Sat control catalog 9.11.2012

5. CABLE USB2.0 - USB-A

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

78

5.j. Plastic mounting bracket for wind sensor

Technical Capabilities

Product code: WSBWM01271020

Wind sensor WS XS Vestamatic

Specifications • Wind sensor for measuring wind speed • For plastic bracket mounting • Compatible with all Vestamatic central, awning and blind controls

Includes

• Wind sensor WS XS Vestamatic WSVM01100310 / 383106390209

Page 84: Sat control catalog 9.11.2012

Product code: ZV76X60X1400

Ground Screws

Ground Screws made of high quality hot-galvanized steel, are widely used as strong supports for many ap-plications: flag poles and masts, timber construction, fencing systems, event structures, boards and banners, gardens and parks, Roads and traffics, sheds and containers etc. For us the important thing is they can be the easy and strong support for Solar Trackers and PV systems.

Key Features

• Foundation screws for any type of soil• Ideal for Photovoltaic Installations• Solid, forged and galvanized steel with welded screw threads• Stability is accomplished by means of compression during insertion to the ground. No other digging is required.• Production process is certified ISO9001:2008, ensuring the highest quality construction, reliability and flexibility.

Advantages

• No cement foundation or any other concrete construction needed• Optimum earthing accomplished by connecting the vertical parts with tin-plated copper wire, avoid ing any additional ground wiring, creating that way a solid, low resistance grounding Ground screws come with a 25-yeat anti-corrosion guarantee• No construction permit required• All systems are adjustable to customer requirements. • All systems are assembled using specialized personnel and machinery• Time saving and cost efficient• Can be subject to weight loads immediately• Environmentally friendly

6. GROUND SCREWS

6.a. Ground Screw

79

Page 85: Sat control catalog 9.11.2012

Model type Ground screw 76X1400 L=1400 d=76/60

Length of ground screw 1400 mm Outside diameter of ground screw 76,45mm x 2,6 mm (inner dia. 71mm with zinc)

Max. diameter of tube you can put in D63,5 mm L=2m

Screw thread size and pitch 620 mm

Surface treatment protection type and thick Hot bath zincking 200 um EN ISO1461

Technical Capabilities

6. GROUND SCREWS

6.a. Ground Screw

80

Page 86: Sat control catalog 9.11.2012

6. GROUND SCREWS

6.a. Ground Screw

81

Page 87: Sat control catalog 9.11.2012

6.b. SET Ground Screws

6. GROUND SCREWS

82

Product code: SETZV14C2X1SP

SET Ground Screws

SET Ground Screws provide a solid foundation whatever your project needs. Our SET Ground Screws is engi-neered for easy installation and provide years of dependable service. There is no need for gigging or laying a concrete foundation, drastically reducing cost and time associated with installation. SET Ground Screws also lessen the environmental impact of your solar project, allowing your panel arrays to blend in more naturally into terrain. Also importantly, SET Ground Screws are easily removable and reusable.

Set Components are:

• Ground Screw: 76x1400mm• Tube D60 2x1000 mm• Junction Clamp d=76/60

Key Features

Convenience

• Easy to install and use • No gigging or poring of concrete needed • Can be used in all types of soil • Fastest possible installation time • Ready to use immediately after installation

Environmentally friendly

• Compact design ensures the least impact on ground and surrounding area • Minimal site preparation needed • Since there is no need for concrete, the ground remains intact after screws are removed

Durability

• Made with galvanized steel and welded screw threads• Can be subject to weight loads immediately after installation • Provides solid foundation in all weather conditions• 25-year anti-corrosion guarantee

Value

• Reduced installation time and cost• Minimal materials required; provides the most cost effective foundation solution• Lowers system buy back times • Removable and reusable

Page 88: Sat control catalog 9.11.2012

Model type SET Ground Screws 76x1400 with tube D60 2x1000 with junction clamp

Length of ground screw 1400mm + 2 x tube D60,3 x 1000 + junction clamp Outside diameter of ground screw 76,45mm x 2,6mm + 2 x D60,3 x 3,25mm

Max. diameter of tube you can put in D63,5 x 3,25mm L=2000mm

Screw thread size and pitch 620mm

Surface treatment protection type and thick Hot bath zincking Zn 200 um EN ISO1461

Technical Capabilities

6.b. SET Ground Screws

6. GROUND SCREWS

Product code: SETZV14C2X1SP

83

Product code: SETZV14C2X1SP

Page 89: Sat control catalog 9.11.2012

6.b. SET Ground Screws

6. GROUND SCREWS

84

Page 90: Sat control catalog 9.11.2012

7. MONITORING SYSTEM - Helios Analytics

85

Professional management, monitoring and presentation of solar tracker

System management, monitoring, remote diagnosis, data adjusting and visualization: the Helios Analytics is the high-performance communication hub for single- to small-scale of solar trackers. It continuously display all the data from the solar trackers on the system side, thereby keeping you informed of the system‘s status at any given time. The Helios Analytics is a multi-functional, energy-efficient data system which offers importing and exporting settings data for solar trackers. Overview Safe• Remote monitoring, diagnosis and configuration of the solar trackers • Quick detection of malfunctions and notification in case of a failure • Powerful data system for importing and exporting all trackers setting data User-friendly• Central administration of all customer and tracker data• Easy remote access via PC• Easy to understand reporting

7.a. Helios Analytics

Product code: PRGSIGHELANA1

Page 91: Sat control catalog 9.11.2012

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

7. MONITORING SYSTEM - Helios Analytics

86

7.a. Helios Analytics

Languages

Software language English

Language versions – manual German, English, French, Italian, Spanish, Slovenian

System requirements

Supported operating systemsWindows XP (installed version of Microsoft .NET Framework > 2.0 is required with 64 bit systems), Windows Vista (32-Bit and 64-Bit), Windows 7 (32-Bit and 64-Bit)

Hardware (minimum requirements)

Processor PIII 800 MHz (XP) / P4 1 GHz (Vista)

Main Memory 512MB (XP) / 1 GB (Vista)

Free hard disk space 265 MB (240 MB .Net / 25 MB application)

Resolution 1024 x 768 pixels

Color depth 256 colors

Communication

Tracker communication USB 2.0, CAN BUS 2.0 A

Type IP address, URL (e.g., DynDns)

Max. number of devices

USB 2.0 / CAN BUS 2.0 A 1 / up to 2000 trackers

RS485 / Ethernet /

Max. communication range

USB 2.0 / CAN BUS 2.0 A 5 m / 500 m (Twisted Pair Cable with cross section 0,7 mm2)

RS485 / Ethernet /

Software

Type Exe

Other Zip

Client Software Requirements No installation-dependent requirements for the operation

System information

Tracker overview Ideally suited for an overview over the solar tracker by presentation of the most important data

System settings Simple parameter setting for an entire device

Current system values

Summary of current device data. The display of minimum and maximum values, sums and averages (depicted for every device category) provides the operator with detailed information about the current status of their solar tracker

Device information

Device overview The most important device information at a single glance

Device settings Individual parameter adjustment for each device

Current device values Detailed information on the current values of the selected device

Information displayed

General information Time, date

System DataPower supply voltage, current motion, position, error codes, angle,tracker version, tracker type

Advanced System Data

Motor AA1, A2, A3, A4, A5 , A6, B1, B2, min range A, max range A, gear ratio A, I motor max A, coordinate mode A, geometry mode A, I motor factor A, night position A, go to reference A

Motor BA1, A2, A3, A4, A5 , A6, B1, B2, min range B, max range B, gear ratio B, I motor max B, coordinate mode B, geometry mode B, I motor factor B, night position B, go to reference B

Common settingsNight position time, link, U supply factor , group, conf. flags, SN1, SN2, SN3, can ID, options, run, delay n.p., run delay, panel wide, panel space, rtc correction, H target angle, V target angle

Individual set-up options

Values Three configurable pre-defined positions for snow, wind, etc.

The weather station for PV plants

Current system values /

Technical Capabilities

Page 92: Sat control catalog 9.11.2012

8. SAT CONTROL WEBSHOP

87

8.a. Sat Control WebShop

Profit from our new online shop!

Conveniently order Sat Control quality from home and profit from:• A wide range of products and services• Surprisingly low prices• The high level of quality of quality of the products and components used and• The schedule effectiveness you have become accustomed to The Sat Control WebShop. 24/7 one-stop shopping for all-round solutions Tailor-madeto your needs fast and at the same level of high quality.

Page 93: Sat control catalog 9.11.2012

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

8. SAT CONTROL WEBSHOP

88

8.a. Sat Control WebShop

Making a Payment

The following outlines the how you can make a payment through the WorldPay Payment Service and how we deal with the transaction.

How does the WorldPay Payment Service work?

1. A shopper visits an e-commerce website and selects the products/services that they would like to buy. 2. The shopper then proceeds to the merchant’s checkout with their shopping basket. This generates a sum-mary description of the purchase that is sent to WorldPay for payment processing. This submis sion is often referred to as the “purchase token”. 3. The shopper is redirected to WorldPay’s secure server where they are presented with a series of payment pages, enabling them to choose their payment method and enter their payment details.

4. WorldPay records the shopper’s payment details against the details submitted in the purchase token, to produce a transaction. 5. WorldPay forwards the transaction details to the card issuer for authentication. The issuer returns an authorised or declined response to WorldPay and a payment response page is then displayed to the shopper.

6. If the transaction was successful, WorldPay will also send the shopper a confirmation email, confirming the transaction details.

For more informations about paying through WorldPay, and for information on the status of your payments for pur-chases made at one of the shops that uses the WorldPay Payment Service, please visit: www.rbsworldpay.com

Page 94: Sat control catalog 9.11.2012

Published by and copyright © 2011:Sat Control d.o.o.Pozenik 10,SI-4207 CerkljeSlovenia

For more information, please contactour Customer Support Center.Phone: +386 4 281 62 15Fax: +386 4 281 62 13(Charges depending on provider)E-mail: [email protected]

Order No. PC2011-V1.1 Printed in SloveniaDispo 34807, c4bs No. 7827fb 2674 440101 WS 11092.0

Printed on elementary chlorine-freebleached paper.

All rights reserved.Trademarks mentioned in this documentare the property of Sat Control d.o.o., its affiliates,or their respective owners.

Subject to change without prior notice.The information in this document containsgeneral descriptions of the technical optionsavailable, which may not apply in all cases.The required technical options should thereforebe specified in the contract.